Characteristics:
• Any Structured E1 in MINI-LINK TN can be used to transport IP DCN with robbed timeslot.
• In an E1 used for robbed timeslot, the timeslots not used for IP DCN transport can be used
for regular traffic.
• It is possible to select any timeslot (1-31*64 kbps) in an E1 for robbed timeslot.
• Max two robbed timeslots connections can be terminated per MINI-LINK TN.
• The two robbed timeslot connections must be on the same cross-connected E1.• MINI-LINK TN can transparently propagate multiple E1s containing robbed timeslot
connections to other MINI-LINK TN nodes. These robbed timeslot connections would be
terminated further out in the network.
• One PPP connection over n*64kbps timeslots is established for each of the robbed timeslot
connections.
• The number of timeslots used for robbed timeslot can be individually set for the two
directions.
DCN over Channalized E1
(“Robbed Timeslots”)
Prepared by: Alan Macieira
Ericsson - Brazil
Date: June / 2011
Rev.: A
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 2/16
TN
NPU
Site A
Site B
Leased Line
TN
NPU
MMU
INPUT E1OUTPUT E1
INPUT E1 OUTPUT E1
MMU BTS
E1 with Traffic
+ DCNOther vendor
Equipment
Other vendor
Equipment
Router
E1 with Traffic
+ DCN
DCN
E1 with Trafficfrom BTS
DCN over Channalized E1
(“Robbed Timeslots”)
BSC
E1 with Traffic
from BTS
Timeslot Empty
Timeslot used for Traffic from BTS
Timeslot used for DCN Traffic
Prepared by: Alan Macieira
Date: June / 2011
Rev.: A
NPU3 B – TR: 4D NPU3 B – TR: 4C
NPU3 B – TR: 4DNPU3 B – TR: 4C
CONNECTIVITY PLAN
Othervendor
TX
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 3/16
Other vendor TX
SITE ASITE B
OSPF ID 0.0.0.0
No Stub
192.168.0.9 / 29
OSPF ID 0.0.0.0
No Stub
192.168.0.1 / 29
USING OSPF PROTOCOL
DCN over Channalized E1
Notes:
By defaul t un-num bered IP over PPP is establ ishedbetween the two nodes.
Prepared by: Alan Macieira
Date: June / 2011
Rev.: A
Other Vendor
Equipment
Other Vendor
Equipment
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 4/16
1 - SITE B configuration
( Robbed Timeslots )
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 5/16
1.1 - Right click Configure > DCN from management tree at Local Craft.
1.2 - On DCN over Traffic choose DCN over Channalized E1 as DCN Service.
CONNECTIVITY PLAN CONFIGURATION
1.3 - Set Interface 1 Settings with the correct E1 coming from BTS
(in this example NPU3 B – TR:4C).
1.4 – Set Clock Source.
1.5 – Set Framing Type.
1.7 - Set Interface 2 Settings with the correct E1 going to opposite node
(in this example NPU3 B – TR:4D).
1.8 – Set Clock Source.
1.9 – Set Framing Type.
1.6 –
Set Timeslots for DCN (in this example TS 1 & 2).
1.10 – Set Timeslots for DCN (in this example TS 1 & 2).
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 6/16
BASIC CONFIGURATION
1.11 - Right click Configure > Basic NE from management tree at Local Craft.
1.12 - Fill NE IP Address, NE Subnet Mask and Default Gateway.
Site B Conf igurat ion:
IP Address: 192.168.0.9
Subnet Mask: 255.255.255.248
Default Gateway: 0.0.0.0
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 7/16
1.13- Right click Configure > DCN from management tree at Local Craft.
1.14 - On OSPF Areas fill Net Address, NE Subnet Mask,
Area ID and Area Type.
OSPF CONFIGURATION
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 8/16
2 - SITE A configuration( Robbed Timeslots )
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 9/16
2.2 - On DCN over Traffic choose DCN over Channalized E1 as DCN Service.
CONNECTIVITY PLAN CONFIGURATION
2.1 - Right click Configure > DCN from management tree at Local Craft.
2.3 - Set Interface 1 Settings with the correct E1 coming from the opposite node(in this example NPU3 B – TR:4C).
2.4 – Set Clock Source.
2.5 – Set Framing Type.
2.7 - Set Interface 2 Settings with the correct E1 going to the BSC direction(in this example NPU3 B – TR:4D).
2.8 – Set Clock Source.
2.9 – Set Framing Type.
2.6 – Set Timeslots for DCN (in this example TS 1 & 2).
2.10 – Set Timeslots for DCN (in this example DCN has been already
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 10/16
2.11 - Right click Configure > Basic NE from management tree at Local Craft.
2.12 - Fill NE IP Address, NE Subnet Mask and Default Gateway.
Site A Conf igurat ion:
IP Address: 192.168.0.1
Subnet Mask: 255.255.255.248
Default Gateway: 0.0.0.0
BASIC CONFIGURATION
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 11/16
2.13 - Right click Configure > DCN from management tree at Local Craft.
2.14 - On OSPF Areas fill Net Address, NE Subnet Mask,
Area ID and Area Type.
OSPF CONFIGURATION
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 12/16
3 – Connectivity Verification( Robbed Timeslots )
CONNECTIVITY VERIFICATION
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 13/16
CONNECTIVITY VERIFICATION
3.1 - Right click Configure > DCN from management tree at Local Craft.
3.3 – If required, a numbered PPP can be set
(in case of ABR for example).
3.2 – By default a un-numbered PPP is created (blank).
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 14/16
CONNECTIVITY VERIFICATION
3.4 – Click on PPP Status.
3.5 – PPP is working properly (UP).
CONNECTIVITY VERIFICATION
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 15/16
CONNECTIVITY VERIFICATION
CONNECTIVITY VERIFICATION
3.6 – Connecting to SITE A
3.7 – Checking OSPF Routing Table
3.8 – Connectivity Test.
To physical connection to SITE A traffic Node can be by USB or Ethernet Port. In this example a USB Port
was used. To connect using Ethernet Port is necessary change IP Address from PC to the same subnet
address from SITE A Traffic Node.
OTHER REFERENCES
8/18/2019 DCN Over Channalized E1
http://slidepdf.com/reader/full/dcn-over-channalized-e1 16/16
OTHER REFERENCES
DCN DESIGN: OSPF PREMISES
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52924&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over Dedicated E1
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52911&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over Channalized E1
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52912&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over VLAN
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52913&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over PDH Radio Linkhttps://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52915&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over SDH Line
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52916&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx
DCN over SDH Radio Link
https://ericoll.internal.ericsson.com/sites/GKO//Lists/GKO/DispForm.aspx?ID=52917&Source=http://
ericoll.internal.ericsson.com/sites/Microwave_Networks/default.aspx