Post on 17-Jun-2020
transcript
WIRING DIAGRAM IN CONDUIT (BY OTHERS)
To fixture
ON/OFF
Con
duit
prov
ided
by
othe
rs
DIM
0-10
V -
0-10
V +
To fixture
Neu
tral
Gro
und
Live
Power input fromprevious fixture
To next fixture
Con
duit
prov
ided
by
othe
rs
SPR5 OR SPR7To fixture
Neu
tral
Gro
und
Live
Con
duit
prov
ided
by
othe
rs
Neu
tral
Gro
und
Live
Power input fromprevious fixture
To next fixture
not required
AmericanColor Code
USE
White Neutral
Purple/Red 0-10V+
Black Live 120 - 480V
Gray/Orange 0-10V -
Green Ground
TENON INSTALLATION
REQUIRED TOOLS
AS DELIVERED
LUMINAIRE (1X)
TORQUE RATCHET
STEP 1. OPEN COVER STEP 2. LOOSEN BOLTS TO LOOSEN U-CLAMPS
STEP 5. MAKE CONNECTIONS WITH WIRE NUTS AND CLOSE COVER
DO NOT REMOVE BOLTS(bolts need to be tightened enough to
support luminaire)
NOTICE
KEEP WIRES CLEARWHEN CLOSING COVER
NOTICE
INSERT TENON ONTO U-CLAMPS
CLAMPS FOR TENON [Ø60mm]Ø2 "3
8
[60mm]4"@ 0°
0°
STEP 4. ADJUST LUMINAIRE USING INTERNAL SCALE AND TIGHTEN BOLTSSTEP 3. INSTALL LUMINAIRE ON TENON
ADJUST TENON ON SCALE (adjustable within -4.5º to 4.5º
in 1.5º increments)
SCALEUSE BUBBLE LEVEL TO INSTALL
LUMINAIRE PARALLEL TO THE GROUND. TIGHTEN BOLTS.
BUBBLE LEVEL
USE SLOTS TO OPEN COVER
4XHEX KEY SIZE 9/16
4XHEX KEY SIZE 9/16
MAGNETIC CLOSURE SYSTEM MAY CAUSE INJURY. KEEP FINGERS CLEAR.
WARNING!
Power input fromprevious fixture
To next fixture
RECOMMENDED TORQUE:250 lbs.in [28 N.m]
SOCKET SIZE: 9/16"
NOTICEWARNING!
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
CAUTIONUNAUTHORIZED FIELD REPAIRS
WILL VOID WARRANTY.
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
1/2” NPT, PG16 OR 20MM STRAIN RELIEF REQUIRED, PROVIDED BY OTHERS
WARNING!
DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK.
WARNING!
WARNING!
FIXTURE CORD SHOULD BE FED THROUGH THE TOP KNOCKOUT HOLE OF THE JBOX.
WARNING!
SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL)
WIRING FROM THE BRANCH CIRCUIT WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL AND/OR
NATIONAL ELECTRICAL INSTALLATION CODES.
MEDIUM AREA LIAMWHITE
lumenicon
2019.02.12MS - R0
p.1/3
drawing number 207624
INSTALLATION INSTRUCTIONSThis product must be installed in accordance with applicable national and local electrical and constructioncodes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury. !
1220 Marie-Victorin Blvd., Longueuil, QC J4G 2H9 CA 1.877.937.3003 P. 514.937.3003 F. 514.937.6289info@lumenpulse.com www.lumenpulse.comCopyright © Lumenpulse Group Inc. AAAA
Confidential and proprietaryLumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
PU8-W1X - WALL MOUNTED DECORATIVE ARM
STEP 2. INSTALL ARM ON WALL PLATE, MAKE CONNECTION AND INSTALL LUMINAIRE
STEP 2. INSTALL BRACKET ON POLE, MAKE CONNECTIONS AND INSTALL LUMINAIRE
STEP 3. WIRING DIAGRAM AT JUNCTION BOX (BY OTHERS)
STEP 1. INSTALL WALL PLATE WALL PLATE DIMENSIONS
RTV silicone
FOR WET LOCATION INSTALLATIONS, USE WEATHER-PROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV
SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS)
WARNING!
JUNCTION BOX(PROVIDED BY OTHERS)
SPR5 OR SPR7
Power input or from
previous fixture
To fixture
To next fixture
Junction box (by others)
LineGroundNeutralWire-nuts
To fixture
Power input or from
previous fixture
To next fixture
Junction box (by others)
From third party dimmer
LineGroundNeutralWire-nuts
0-10V -0-10V +
0-10V DIMMINGTo fixture
Power input or from
previous fixture
To next fixture
Junction box (by others)
LineGroundNeutralWire-nuts
Not requiredNot required
ON/OFF
PLEASE CONSIDER STREET SIDE WHEN
DRILLING
NOTICE
PU8-S1X - VARIABLE HEIGHT MOUNTING ON SQUARE POLE DECORATIVE ARM
STEP 1. LOCATE HOLES ON POLE OR REFER TO DRILLING PATTERNS TO CREATE THEM
90˚270˚
0˚
180˚
STREET SIDE
2X5/16-18HEX KEY SIZE 5/32
MOUNTING HARDWARE (4X)
(PROVIDED BY OTHERS, USE APPROPRIATE
SCREWS)
NOTICE
WIRE MUST BE AT LEAST 12"
[300mm]
MAKE SURE TO FEED THE WIRES THROUGH THE CENTER HOLE.
NOTICE
4XWALL PLATE
HOLE FOR WIRES
HOLE (4X)
2[64mm]
"12
[Ø11mm]
[76mm]
[152mm]
716
1[35mm]
"38
1"[Ø25mm]
Ø
Ø
3"
6"
AmericanColor Code
USE
White Neutral
Purple/Red 0-10V+
Black Line 120 - 480V
Gray/Orange 0-10V -
Green Ground
SUPPORT PLATE
2X3/8-16HEX KEY SIZE 9/16
1 2 3
INSTALL LUMINAIRE ON DECORATIVE ARMACCORDING TO
TENON INSTALLATIONSTEPS ON FIRST PAGE.
PLACE ARM ON WALL PLATE USING
THE HOOK
2
INSTALL LUMINAIRE ON DECORATIVE ARMACCORDING TO TENON INSTALLATION
STEPS ON FIRST PAGE.
1
INSTALL DECORATIVE ARM ON POLE USING
PROVIDED HARDWARE
SECURE FIXTURE USINGTHE SCREW AT THE BOTTOM
OF THE ARM.(INCLUDED WITH THE WALL BRACKET
HOLE (2X)FOR 3/8-16 BOLTS
[57mm]
[216mm]
1[43mm]
"34
8 "12
2 "14
[Ø73mm]2 "7
8
HOLE FOR WIRES
Ø
MEDIUM AREA LIAMWHITE
lumenicondrawing number 207624
INSTALLATION INSTRUCTIONSThis product must be installed in accordance with applicable national and local electrical and constructioncodes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury. !
2019.02.12MS - R0
p.2/3 1220 Marie-Victorin Blvd., Longueuil, QC J4G 2H9 CA 1.877.937.3003 P. 514.937.3003 F. 514.937.6289info@lumenpulse.com www.lumenpulse.comCopyright © Lumenpulse Group Inc. AAAA
Confidential and proprietaryLumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
POLE-TOP MOUNTING DECORATIVE ARM
EXTERNAL TENON
INTERNAL TENON
PU2-SMLHorizontal small curve pole top
PU2-LRGHorizontal large curve pole top
PU4-S1E Single T shape pole top
PU4-S2E Double T shape pole top
PU5-S1E Single curve horizontal pole top
PU5-S2E Double curve horizontal pole top
PU8-S1ESingle tenon
PU8-S2EDouble tenon
PU8-S3ETriple tenon
PU8-S4EQuadruple tenon
Ø4"
INTERNAL ADAPTER
POLE EXTENSION
2X (3X@120°)Ø5/16 SET SCREWWITH FLAT LOCKWASHER AND NYLON INSERT LOCKNUT (INCLUDED WITH THE POLE)
8[203mm]
"
[Ø102mm]3
[76mm]"
7[178mm]
"
6XHEX KEY SIZE 5/16
[307mm]
PUSH ALL THE WIRES AND CONNECTORS
INTO THE POLE.
NOTICE
12 "116
[117mm]
4 "58
2X (3X@120°)Ø5/16 SET SCREWWITH FLAT LOCKWASHER AND NYLON INSERT LOCKNUT (INCLUDED WITH DECORATIVE ARM)
Ø4" [Ø102mm]
5XHEX KEY SIZE 5/16
STEP 1. INSTALL LUMINAIRE AND MAKE CONNECTIONS
2
INSTALL LUMINAIRE ON DECORATIVE ARMACCORDING TO TENON INSTALLATION
STEPS ON FIRST PAGE.
1
INSTALL DECORATIVE ARM ON POLE USING
PROVIDED HARDWARE
PU8 DECORATIVEARM SHOWN
MEDIUM AREA LIAMWHITE
lumenicondrawing number 207624
INSTALLATION INSTRUCTIONSThis product must be installed in accordance with applicable national and local electrical and constructioncodes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury. !
2019.02.12MS - R0
p.3/3 1220 Marie-Victorin Blvd., Longueuil, QC J4G 2H9 CA 1.877.937.3003 P. 514.937.3003 F. 514.937.6289info@lumenpulse.com www.lumenpulse.comCopyright © Lumenpulse Group Inc. AAAA
Confidential and proprietaryLumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.