Post on 21-Oct-2021
transcript
ENT & ALLERGY PARTNERS May 28, 2021
ENT & ALLERGY PARTNERS CLINICSD01
SMHa, INC.400 Hibben St.
Mount Pleasant, SC 29464Jeff Johnston & Jennifer Schutte
843.881.7642j.johnston@smha.com
Ward Edwards Engineering (Owner's Consultant)PO Box 381
Bluffton, SC 29910Heath Duncan, PE843.837.5250 x133
hduncan@wardedwards.com
architect
civil
ADC Engineering1226 Yeamans Hall Road
Hanahan, SC 29410Mark Dillon, PE, SE
843.735.5140markd@adcengineering.com
structural
mep & fire protection
DWG Consulting Engineering1009 Anna Knapp Boulevard, Suite 202
Mount Pleasant, SC 29464Jill Meyer, PE SC
843.849.1141jmeyer@dwginc.com
Charleston ENT Real Estate Holdings LLC2295 Henry Tecklenburg Drive
Charleston, SC 29414Craig Kilgore
client
landscape architect
JK Tiller Associates, Inc.181 Bluffton Road, Suite F203Bluffton, South Carolina 29910
Josh K Tiller, PLA, ASLA843.815.4800
josh@jktiller.com
PERSPECTIVE-AERIAL LOOKING NORTH PERSPECTIVE-AERIAL LOOKING SOUTH
PERSPECTIVE-STREETVIEW LOOKING SOUTHPERSPECTIVE-STREETVIEW LOOKING NORTH
general contractor
Fraser Construction12B Arley Way, Suite 200
Bluffton SC 29910Joe Fraser III843.815.4747
jfraser@fraser-construction.net
DEVELOPMENT TEAM
ENT & ALLERGY PARTNERS CLINIC6 ARLEY WAY
WESTBURY PARK (LOT 20B)BLUFFTON, SOUTH CAROLINA 29910
SMHa Project Number: 1908.00
ATTACHMENT 4
24'-0
1/2
"3
3'-10 1
/2"
7'-3"
11'-6" 15'-0" 19'-9 1/2" 13'-2" 6'-0" 8'-0" 26'-1"
4'-0"
7'-7"
10'-0"
10'-0"
10'-0"
7'-8"
6'-6"
7'-0"
5'-4"
10'-0" 10'-0" 15'-9 1/2" 6'-8" 6'-6" 26'-0"
7'-2 1/2" 9'-3 1/2" 13'-2" 7'-4" 5'-8" 13'-0"
WAITING
ASC
BREAK
WORK
DOC
LOUNGE
PRE OP 1
MANAGER
TLT
RECEPT TLT
PRE OP 3
PRE OP 2
CLEAN
LINEN
TLTTLT
Rx
PACU 1PACU 2PACU 3
PACU
CORR
MED GAS
STERILE
CORR
PRE-OP
CORR
NURSE
NURSE
CO
DE
/E
KG
(2
)
BLKT
20
SEATS
WHEEL CHAIRS
DISCHARGE
ASC
PATIENT
ENTRY
ASC STAFF /
DELIVERIES
CLINIC
STAFF
CORR
20'-7"
1'-0"
8'-6"
8'-11
1/2
"6
'-2"
12'-4
1/2
"1
1'-5
1/2
"2
0'-10"TE
MP
DE
LIV
ER
Y
ASC
18 seats
CLINIC STAFF/
DELIVERIES
CLINIC
PATIENT
ENTRY
ELECTRICALSTERILE
SUPPLY
CLEAN
WORK
SOILED
WORK
OR 1PROCEDURE
8'-9 1/2"18'-6"19'-0"
12'-6"
32'-8
1/2
"2
5'-2
1/2
"
STAFF
CHANGING
STAFF
CHANGING
TLT / SHW
ST
AF
F I
NF
O
14'-6"
GEN TXFR
15'-9"
9'-4"
11'-0"
11'-0"
11'-0"
SHOT
ADMIN
ALLERGY
EXAM 1
EXAM 2
EXAM 3
EXAM 4
VEST.
AUDIO 1
AUDIO 2
EXAM 5
EXAM 6
EXAM 7
EXAM 8
TOILET
CHECK-IN
CHECK-OUT
UTILITY
NURSECIRC
KIDS
JANCT
DICTATION
CIRC
TOILET
8'-0" 6'-1"
8'-4"
6'-5 1/2" 6'-10" 6'-4 1/2" 6'-4 1/2"
10'-0" 10'-0"
9'-0" 11'-0"
9'-6"
8'-11
1/2
"6
'-2"
12'-0" 6'-8"
0"
8'-2"
5'-4"
WAITING
7'-11
1/2
"1
3'-0"
10'-10"
11'-0"
11'-0"
11'-0"
6'-8"
13'-6"
14'-1" 6'-2" 13'-8 1/2" 6'-4 1/2" 14'-1"
14'-6"
EXHA
UST
RETURN RETURN
EXHAUST
FLAMMABLE
WASHER
STRLZR
STRLZR
LIN
TR
SUPPLIES
LIN
TR
SUPPLIES
PASS
AREA ANALYSIS
CLINIC 4,906 SF
ASC 7,741 SF
12,588 SF
Vestibule & Entries 300 SF
ASC Discharge 572 SF
BLDG GROSS AREA: 13,519 SF
89
' - 9
"9
' - 1
1 3
/8"
AUDIO
FITTING
SCRUB
SINKS
OR NURSE STATION
NOURISHMENT
BLANKETWARMER
SOILED
LINEN
MAIN
SUPPLY
JANITOR
VAC/RISER/H20
DATA
CLINIC
BREAK
TOILET
DOC
WORK
DATA
ASC
COVERED
DISCHARGE
GE
NE
RA
TO
R
66
' - 4
5/8
"1
1' -
6"
12
' - 0
"
89' -
10 5
/8"
58' - 1 5/8" 6' - 9 5/8" 34' - 8 3/4" 13' - 4 1/4" 26' - 10"
139' - 10 1/4"
COMMON
VESTIBULE
6
C E
8' -
2"
8' -
2"
BA D F G H
4
2
1
5
3
3" 23'-8 1/2" 21'-0" 23'-0" 27'-0" 4'-4" 26'-2" 15'-5"
3 1
/2"
13'-4"
1'-3"
14'-7"
2'-10"
12'-8"
30'-3 1/2" 36'-5 1/2" 1'-4"
RTURTURTU
11'-0" TRUSS BRG
TOP OF SLAB
3.5:12
ROOF SYSTEM 1:- FIBERGLAS ASPHALT SHINGLES- HIGH TEMP SELF ADJERING MEMBRANE- 5/8" PLYWOOD ROOF SHEATHING- R-38 OPEN CELL SPRAY INSULATION- SPRAY APPLIED THERMAL BARRIER- LT GAUGE METAL STUD TRUSSES
ROOF SYSTEM 2:- 60 MIL FULLY ADHERED PVC - 3/8" COVER BOARD- TAPERED INSULATION TO ACHIEVE POSTIVE DRAINAGE- 5/8" PLYWOOD SHEATHING- R-38 OPEN CELL SPRAY INSULATION- SPRAY APPLIED THERMAL BARRIER- LT GAUGE METAL STUD TRUSSES
STEEL COLUMN AND BEAM
STEEL COLUMN AND BEAM
6421 53
ENT & ALLERGY PARTNERS May 28, 2021
FLOOR PLANSD02
SCALE: 1/8" = 1'-0" (REFERENCE: SD04)2BUILDING SECTION
NOTE:OPENINGS/WINDOWS DO NOT COORDINATE BETWEEN PLAN AND ELEVATIONS
4'0 8' 16'
4'0 8' 16'
ATTACHMENT 4
TOP OF SLAB0"
TRUSS BEARING10'-0"11'-0"
ASR
PAS
FCT-1x
BRK
ACW (QUANT. 4 TRANSOMS)
ACW (QUANT. 6 TRANSOMS OVER
6 FULL SIZE)
SCREEN:- GALV 3x3 SQ STL POSTS @ 5' (60") OC- PT WOOD 2x4 FRAME- PT 1x4 LOUVER SLATS- HIGH PERFORMANCE PAINT & SOLID STAIN
BRK
12'-6" ENTRY BRG
ACW (QUANT. 8 TRANSOMS)
11'-0" TRUSS BRG
TOP OF SLAB
ASR
PAS
FCT-1x
BRK
ACW (QUANT. 2 TRANSOMS, OVER A SLIDING STANLEY AUTO ENTRY DURASTORM 3000, FULL BREAKOUT DOOR)
HMD
ACW (QUANT. 5 TRANSOMS)
SCREEN:- GALV 3x3 SQ STL POSTS @ 5' (60") OC- PT WOOD 2x4 FRAME- PT 1x4 LOUVER SLATS- HIGH PERFORMANCE PAINT & SOLID STAIN
HMD
BRK
12'-6" ENTRY BRG
TOP OF SLAB0"
TRUSS BEARING10'-0"11'-0"
ASR
ACW(QUANT. 20 TRANSOMS)
ASFACW(QUANT. 10 TRANSOMS)
PAS
FCT-1x
BRK
BRK
ACW (QUANT. 6 TRANSOMS)ACW (QUANT. 12 TRANSOMS)ACW (QUANT. 8 TRANSOMS)
BRK
BRK
ACW
AUTOMATIC ENTRY/PUSH BUTTON HARDWARE
ASF
TOP OF SLAB0"
TRUSS BEARING10'-0"11'-0"
ACW (QUANT. 6 TRANSOMS)ACW (QUANT. 3 TRANSOMS)
ASR
ASF
PAS
FCT-1xBRK
PAS
ACW (QUANT. 6 TRANSOMS,
3 FULL SIZE)
HMD
ACW
ROOF WELL
TOP OF SCREEN
3' -
0"
5' -
6"
RTU BEYOND
SCREEN:- GALV 3x3 SQ STL POSTS @ 5' (60") OC- PT WOOD 2x4 FRAME- PT 1x4 LOUVER SLATS- HIGH PERFORMANCE PAINT & SOLID STAIN
EXTERIOR FINISH LEGEND - BASIS OF DESIGN
MARK MATERIAL BASIS OF DESIGN / DESCRIPTION
ACW ALUM CLAD WOOD WINDOW MANUF: PELLA ARCHITECT SERIESSTYLE: FIXED/DIRECT SETMAT'L: ALUMINUM CLAD WOODEXTERIOR FINISH: KYNAR 500COLOR: CUSTOM COLORINTERIOR FINISH: PAINT
ASF ALUM STOREFRONT DOOR MANUF: YKK 50D WIDE STILE EXTERIOR DOORAND FRAME YKK YES 45 TU FRAME
COLOR: CUSTOM COLOR
ASR ARCHITECTURAL SHINGLE CERTAINTEED, LANDMARK, TIMBERLINE25 YEAR WARRANTYCOLOR DRIFTWOOD
BRK BRICK VENEER MANUF: PALMETTO BRICKSIZE: MODULARPATTERN: FLEMISH BONDFINISH: RIVIERA MODULARMORTAR COLOR: WHITE
BKT BRACKET - HEAVY TIMBER 4X6 HEAVY TIMBERFINISH: PAINTCOLOR: TBD
DS DOWNSPOUT & BOOT STYLE: ROUNDSIZE: SEE ROOF PLANFINISH: FACTORYCOLOR: TBDBOOT: ZURN Z191-RD
GUT GUTTER STYLE: HALF ROUNDSIZE: SEE ROOF PLANFINISH: FACTORYCOLOR: TBD
FCF FIBER CEMENT FASCIA 3/4" THICK, SEE DETAIL FOR WIDTHFINISH: SMOOTHCOLOR: TBD
FCP FIBER CEMENT PANEL 5/16" THICK PANELFINISH: SMOOTHBATTENS: 3 1/2" FIBER CEMENT TRIMCOLOR: TBD
FCS-1 FIBER CEMENT SIDING TYPE: LAP; 5 1/4" X 5/8" THICK, 4" EXPOSUREFINISH: SMOOTHCOLOR: TBDTRIM: 1 1/2 CEMENTITIOUS
FCT FIBER CEMENT TRIM CEMENTITIOUSFINISH: SMOOTHSIZES: 3/4" THICK OR 1 1/2"COLOR: TBD
HMD HOLLOW METAL DOOR EXTERIOR GRADE, EXTRA-HEAVY-DUTY PROVIDE THERMAL RATED DOORS/WELDED FRAME FACTORY PRIMEDPAINTED WITH 2 COATS ALKYD, EXTERIOR, SEMI/G
LF-E LIGHT FIXTURE - EXTERIOR SEE ELECTRICAL
LVR FIXED ALUMINUM LOUVER 2-COAT FLUOROPOLYMER FINISHCOLOR: SELECTED FROM MANUF'S FULL RANGE
MWP METAL WALL PANEL MAT'L: WEATHERING STEEL SHEETSTYLE: LAP-SEAM SHINGLED (2" LAP); RUNNING BOND; FINISH: NATURALLY WEATHERING
PAS POLY-ASH SIDING MANF: BORAL COMPOSITES, INCSTYLE: TRUEXTERIOR - CHANNEL PROFILESIZE: 1X6FINISH: SMOOTHCOLOR: TBD
SI-E SIGNAGE - EXTERIOR ALLOWANCE OF $25,000 EACH
ENT & ALLERGY PARTNERS May 28, 2021
ELEVATIONSSD03
SCALE: 1/8" = 1'-0" (REFERENCE: A100)1EAST ELEVATION
SCALE: 1/8" = 1'-0" (REFERENCE: A100)3WEST ELEVATION (DISCHARGE)
SCALE: 1/8" = 1'-0" (REFERENCE: A100)4SOUTH ELEVATION (PARKING ENTRY)
SCALE: 1/8" = 1'-0" (REFERENCE: A100)2NORTH ELEVATION
NOTE:OPENINGS/WINDOWS DO NOT COORDINATE
BETWEEN PLAN AND ELEVATIONS
4'0 8' 16'
4'0 8' 16'
4'0 8' 16'
4'0 8' 16'
ATTACHMENT 4
2
SD02
LOW SLOPE ROOF ARE60 MIL PVC, FULLY ADHERED
3.5/121/4" / 12
LOW
HIGH
5" HALF ROUND GUTTERS AND DOWNSPOUTS
LOCATED 30 FEET ON CENTER (FULL PERIMETER)
ALUMINUM, CUSTOM COLORED
3.5/12
3.5/12
3.5/12
2" / 12
2" / 12
3.5/12
3.5/12
3.5/12
50'-0"
38'-1"
ENT & ALLERGY PARTNERS May 28, 2021
ROOF PLANSD04
ARCHITECTURAL SHINGLE: CERTAINTEED/LANDMARK "TIMBERLINE 25 YEAR WARRANTY, COLOR: DRIFTWOOD.ALL VALLEY FLASHINGS TO BE ALUMINUM/OPEN VALLEYS.
ATTACHMENT 4