Gas Fired, Direct Vent or Induced Draft, Cast Iron Water ...

Post on 05-Nov-2021

1 views 0 download

transcript

ESC™

Gas Fired, Direct Vent or Induced Draft,Cast Iron Water Boiler

• 85%AFUE,ENERGYSTAR®certified

• Electronicignition

• EquippedwithIQControlSystem™

• 60–243MBH(7sizes)

• Idealforinstallationswherechimneyventingisnot possible,industrystandardtappinglocationspermit easeofreplacementforthousandsofexistingboiler installations

• Rearjacketpanelofboilerisflatwithnoprotrusions, simplifiestransportandenablesflushinstallations

• Solid,reliable,American-madecastironheat exchangercanacceptreturnwatertempsas lowas110°F

• Lifetimelimitedwarranty

• ConsistsoftheIntelligentHydronicControland IQOptionPanel

Intelligent Hydronic Control• Combinesaquastat,relay,andignitionfunctionsintoasinglemodule

• Twocustomizableintegratedswitchingrelaysforeasyadditionofadditionalheatingzoneorindirectwaterheater

• Energysaving“thermalpurge”,whichworksbycirculatingresidualwarmwater(140°orabove)intheheatingsystembeforefiringtheboiler

IQ Option Panel• Enablestheeasyplug&playinstallationofoptionalfeaturessuchasoutdoorreset,LWCO,andhighlimit

Optional Touchscreen• LCDdisplaysallboilersettings,diagnostics,andtroubleshootinginsentences,notcodes

boilercontrol

optionpanel

optioncard

controlsystem

85% Efficient!

©2013U.S.BoilerCompany,Inc.-Lancaster,PAPhone:1-888-432-8887

PrintedintheU.S.A.FormNo.USBL11091 11/13-15ms www.usboiler.net

ESC Dimensions & Connections

Model

Dimensions (inches) Connections (inches) WaterContent (gal.)Width Height Depth Supply Return

Gas Valve

Relief Valve

ESC-3 12-3/4 41 33 1-1/4 1-1/4 1/2 3/4 2ESC-4 15-1/2 41 33 1-1/4 1-1/4 1/2 3/4 3ESC-5 18-1/2 41 33 1-1/4 1-1/4 1/2 3/4 4ESC-6 21-1/2 41 33 1-1/4 1-1/4 1/2 3/4 5ESC-7 24-3/4 41 33 1-1/4 1-1/4 3/4 3/4 6ESC-8 24-3/4 41 33 1-1/4 1-1/4 3/4 3/4 7ESC-9 30-3/4 41 33 1-1/4 1-1/4 3/4 3/4 8

*ENERGYSTAR®ratedNOTE:An“N”insuffixisfornaturalgas,an“L”isforLPgas

ESC: Technical InformationESC Ratings & Specifications

Model AFUE%*Input

(MBH)

DOE HeatingCapacity(MBH)

Net AHRI (MBH)

Vent Size(Inches)

Approx. Shipping Weight. (lbs.)

ESC-3* 85.5 60.8 52 45 3 250ESC-4* 85.4 91.2 78 68 3 300ESC-5* 85.3 121.6 104 90 3 350ESC-6* 85.2 152.0 130 113 3 410ESC-7* 85.0 182.4 156 136 3 460ESC-8 84.5 212.8 180 157 4 510ESC-9 84.0 243.2 206 179 4 560

Standard Equipment • Insulatedsleek,modernjacket• Heavygauge1”baseinsulation• IntelligentHydronicControl–Simpleself-diagnostic controlsystemwith3-digitreadoutforstatussettings anderrors• IQOptionPanel,acceptsplug&playIQOptionCardsfor –OutdoorresetwithDHWpriority –Autoormanualresetlowwatercutoff –Autoormanualauxilliaryhighlimit• Step-openingredundantgasvalve• Stainlesssteelburnertubes• Stainlesssteelfluegasbaffles• 110°Fminimumreturntemperaturerating• Sparkignitionwithcontinuousretry• User-friendlywiringwith120VJ-box• Taco007circulatorwithpipingwithwiringharness• Castironsectionassembly• Differentialventpressureswitch• Boilerdrainvalve• Castironsupplymanifoldwithsafetyreliefvalvetapping

ASM

E

H

FLOORLINE

**

41”

4” “W” 1”

VENTINTAKE

34”ELECTRICAL

27”SUPPLY

18”GAS

15”RETURN

FLOORLINE0”

0” 4” 15”19”22”

4”

33”

1”

VENTILATION AIR INLET OPENINGS***

12” MAX

12” MAX

VENT INTAKE

NOTES:* Vent pipe minimum clearance to combustible material is (4) inches when vent is installed in a fully enclosed chased application, or (3) inches when vent is installed with at least one side open, similar to a joist bay application** Add height required to maintain 6” clearance from all breeching components*** Area of each opening 1 sq. inch for each 1,000 BTUH input - with minimum of 100 sq. Inches. Height of opening should be half the width.