Post on 01-Jan-2019
transcript
INSTALLATION MANUAL w w w. inv i s i ra i l . com
4 PRE-INSTALLATION REQUIREMENTS
4 BOLT SIZE CHART
5 POST BLOCKING DETAILS
6 POST INSTALLATION
6 ON-CENTRE POST MEASUREMENT CHART
7 FASCIA MOUNT POST CONNECTION DETAILS
8 GLASS SPECIFICATIONS
8 CONCRETE CONNECTION DETAILS
9 SPACER INFORMATION
10 - 11 STAINLESS STEEL HANDRAIL TOP MOUNT INSTALLATION
12 STAINLESS STEEL GLASS CONNECTOR INSTALLATION General Information InvisiPost - Connector to Connector InvisiPost - Connector to Universal Angle Bracket
13 InvisiPost - Universal Angle Bracket to Universal Angle Bracket InvisiPost - End Post with Connector
14 InvisiPost - End Post with Universal Angle Bracket VISTA POST and WOOD POST CONNECTOR INSTALLATION Straight Run Connector
15 Universal Angle Bracket
16 LITE 10 NYLON GLASS CONNECTOR INSTALLATION Lite 10 Angle Bracket
17 GLASS PANEL INSTALLATION Stainless Steel Connectors Lite 10 Connectors
18 STAIR GLASS and CUSTOM HORIZONTAL GLASS
19 INVISIPOST POSITIONING DETAIL DIAGRAMS House or End of Run Beside Stairs Inside 90 degrees Outside 90 degrees
20 Inside 90 degrees split
Outside 90 degrees split Inside 45 degrees Outside 45 degrees
21 Inside 45 degrees split Outside 45 degrees split Inside 22.5 degrees split Outside 22.5 degrees split
22 InvisiPost Flange Base
23 ALX POST POSITIONING DETAIL DIAGRAMS House or End of Run Inside 45 degrees split Outside 45 degrees split Inside 22.5 degrees split Outside 22.5 degrees split
24 ALX Post Flange Base
25 VISTA POST POSITIONING DETAIL DIAGRAMS House or End of Run Beside Stairs Inside 90 degrees Outside 90 degrees
26 Inside 45 degrees w/stainless steel connectors
Outside 45 degrees w/stainless steel connectors Inside 45 degrees w/Lite 10 connectors Outside 45 degrees w/Lite 10 connectors
27 Inside 45 degrees split w/stainless steel connectors Outside 45 degrees split w/stainless steel connectors Inside 45 degrees split w/Lite 10 connectors Outside 45 degrees split w/Lite 10 connectors
28 Vista Post Flange Base
29 INVISIPOST FASCIA MOUNT POSITIONING DIAGRAMS
Corner Post Inside 90 degrees Outside 90 degrees Inside 45 degrees
30 Outside 45 degrees Beside Stairs
31 VISTA POST FASCIA MOUNT POSITIONING DIAGRAMS
Corner Post Inside 90 degrees Outside 90 degrees
32 Inside 45 degrees w/stainless steel connectors Inside 45 degrees w/Lite 10 connectors
33 CUSTOM HORIZONTAL GLASS ORDER FORM
34 INVISIRAIL SCRATCH PAD
3
4
PRE-INSTALLATION
BOLT CHART
Connector to Universal Angle Bracket
TOOLS / SUPPLIES REQUIRED:• Two (2) people are necessary to handle and install glass• Tape measure• Bolts as specified on the InvisiRail Bolt Chart• Drill with assorted bits including a T-40 bit for deck fasteners and a 10mm hex socket if connecting to aluminum or wood posts• Shims for fine height adjustment to help in pin alignment during glass installation• Washers for flange base adjustment to ensure posts are plumb during installation• Two (2) short pieces of 2”x4” or 4”x4” to support glass during installation• Pipe cutter or saw with carbide-tipped metal cutting blade if installing stainless steel handrail or top rail
There must be proper blocking in joists to secure posts!
5
BLOCKING DETAIL
4” LONG HEADLOKSCREWS (0.188” DIA)
REFER TO SECTIONFOR PLACEMENT
HEADLOKSCREWS
4” LONG HEADLOKSCREWS (0.188” DIA)3 TOTAL
5/16” X 6” GRK RSS SELF-DRILLING SCREWS
ELEVATION
DECKING MATERIAL BETWEEN BASE PLATE AND JOISTS
INVISIPOST
VISTA POST WITH BASE PLATE
ALTERNATIVE BLOCKING DETAIL
(4) 5/16” X 6” GRK RSS SELF-DRILLING SCREWS
(4) 3/8” X 5” LAG SCREWS EACH END
6
Only install one section at a time.
DO nOT InSTall all POSTS BefORe InSTallIng glaSS as minor adjustments may be needed to the post.
Start with the post indicated on the layout diagram sent with your order.
If necessary, use washer/s beneath the flange base to ensure your post is completely plumb.
Refer to the post positioning diagrams in the back of this manual that apply to your layout.
Set the next post according to the on-centre chart below and the glass panel indicated on your layout diagram.
POST INSTALLATION
2.50
.31
4.75
.38
42.19
2.88
.75
33.50
A 6X .38 THRU ALL
0 .38 1.13 2.88 3.63 4.38 4.75
0
.38
1.2
5 2
.13
2.5
0
DETAIL ASCALE 1 : 4
DO NOT SCALE DRAWING
NIS 4247-002SHEET 1 OF 1
UNLESS OTHERWISESPECIFIED:
SCALE: 1:8 WEIGHT: 9.77
REVDWG. NO.
BSIZE
DESCRIPTION:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:WELDMENTS 1/8FRACTIONAL 1/32BEND 2DEG.TWO PLACE DECIMAL .01THREE PLACE DECIMAL .003
REVISION
DATELEVEL
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFNEUFELDT INDUSTRIAL SERVICES INC. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFNEUFELDT INDUSTRIAL SERVICES INC. IS PROHIBITED.
PHONE:(651) 388-4347FAX:(651) 388-5976P.O. BOX 51, RED WING, MN 55066
CUSTOMER:
PROJECT:K. MERKLE
GLASS RAILINGPOST WELDMENT (FLUSH MOUNT)
GLN 05/24/17JUSTIN
NONEAISI 304
2.50
.31
4.75
.38
42.19
2.88
.75
33.50
A 6X .38 THRU ALL
0 .38 1.13 2.88 3.63 4.38 4.75
0
.38
1.2
5 2
.13
2.5
0
DETAIL ASCALE 1 : 4
DO NOT SCALE DRAWING
NIS 4247-002SHEET 1 OF 1
UNLESS OTHERWISESPECIFIED:
SCALE: 1:8 WEIGHT: 9.77
REVDWG. NO.
BSIZE
DESCRIPTION:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:WELDMENTS 1/8FRACTIONAL 1/32BEND 2DEG.TWO PLACE DECIMAL .01THREE PLACE DECIMAL .003
REVISION
DATELEVEL
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFNEUFELDT INDUSTRIAL SERVICES INC. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFNEUFELDT INDUSTRIAL SERVICES INC. IS PROHIBITED.
PHONE:(651) 388-4347FAX:(651) 388-5976P.O. BOX 51, RED WING, MN 55066
CUSTOMER:
PROJECT:K. MERKLE
GLASS RAILINGPOST WELDMENT (FLUSH MOUNT)
GLN 05/24/17JUSTIN
NONEAISI 304
ON-CENTRE CHART
69 13/1667 7/865 5/1662 5/1659 5/1657 13/1655 7/853 5/1651 13/1649 7/847 5/1644 5/1641 5/1638 5/1635 5/1632 5/1629 5/1623 5/1617 5/1611 5/16
1/8
5/85/85/81/8
5/81/16
5/85/85/85/85/85/85/85/85/85/8 1/2
1/21/21/21/21/21/21/21/21/2
1/2
1/21/21/2 3/4
3/43/41/41/43/41/41/43/43/43/43/43/43/43/43/43/43/4 3/4
3/43/43/43/43/43/43/43/43/41/41/43/4
3/43/4
1/41/4
3/43/41/41/41/43/43/4
3/43/4
1/4
1/41/41/41/41/41/41/41/41/41/4 1/4
1/41/41/41/41/41/41/41/41/4
1/4
1/41/41/43/4
3/43/4
3/43/4
1/21/21/2
1/2
1/21/21/2
1/21/2
1/21/2
1/21/2
1/2
1/21/21/21/21/2
1/2
1/21/2
1/21/21/21/21/21/21/2
1/21/21/21/21/2
1/8
1/8
w/Vista
FASCIA MOUNT CONNECTION
7
FASCIA MOUNT CONNECTION
HEADLOKSCREWS
8
CONCRETE CONNECTION
GLASS PANELS
ALTERNATIVE CONNECTION:3/8” x 4” COBRA TORK CARBON STEEL ANCHOR-
42” R
ail H
eigh
t: 3
8.75
” • 3
6” R
ail H
eigh
t: 32
.75”
42” R
ail H
eigh
t: 33
.5” •
36”
Rai
l Hei
ght:
27.
5”
2.75”
2.5”
Tempering
Spec’d as per
Glass Panels
3.75”
deck / surface
6.5”
40”
9
SPACERS
Your post/panel layout diagram may indicate the requirement of spacers at certain locations.
Spacers are used to make up small distances in the overall rail length in order for the railing to fit properly on the deck.
Shown at right is an example of how spacers are identified on a layout. Below it is a picture of how the spacer looks after installation.
InvisiRail spacers for stainless steel connectors come in 3/8” (10mm), 1/2” (13m), 3/4” (19mm) and 1” (25mm) sizes.
Spacers for lite 10 nylon connectors come in 1/4”, 3/8”, 1/2” and 3/4” sizes.
When referencing the on-centre chart to position your posts be sure to aDD the spacer dimension where indicated.
(2) x 1/2” indicates that one spacer must be installed behind the top connector and one
behind the bottom connector.
1” spacers
10
GENERAL INFORMATION
Handrail brackets are installed between posts and glass connectors / angle brackets, replacing the backing plates packaged with the connectors.
Refer to post detail drawings to determine the type of handrail bracket required with each post.
HANDRAIL PIPE INSTALLATION
Install appropriate left / right brackets on all intermediate and end posts and corner brackets on all corner posts.
Remove the 1” bolt from the pivot and use the provided 1 1/2” bolt to connect the pivot to the bracket.
Carefully measure to determine the lengths of handrail required and cut your pipe to length using a pipe cutter or saw with a carbide-tipped metal cutting blade.
Joiners may be required for long spans requiring multiple lengths of pipe.
To maintain a seamless length with multiple pipe pieces use the “male” joiners at the un-cut pipe ends. Rough-cut pipe can be hidden with “female” joiners and/or in the “female” ends of the corner pivots.
Pre-drill pilot holes and secure pipe to inline brackets with tapping screws. 5/32” cobalt- tipped drill bit and screws are provided.
Secure pipe to corner brackets using set screws located on the underside of the pivot.
fixtures (joiners, pivots or domed ends) may be further secured to the pipe using provided glue.
STAINLESS STEEL HANDRAIL TOP MOUNT INSTALLATION
Corner pivot
male / female joiners
42mm (1 5/8”) diameter pipe with end cap
InvisiPost handrail bracket -- right hand side
JOIST
InvisiPost handrail bracket -- left hand side
JOIST
InvisiPost handrail bracket -- inside 90 cornero
JOIST
InvisiPost handrail bracket -- outside 90 cornero
JOIST
Use right hand bracket for middle post or left end post
Use left hand bracket for middle post or right end post
Right hand bracket
Left hand bracket
InvisiPost Handrail Brackets
Corner bracket
Variable bracket for non90-degree angles
Use short corner bracket for outside 90-degree corners
Use long corner bracket for inside 90-degree corners
11
InvisiPost with short corner bracket and pivot on outside 90-degree corner InvisiPost with long corner bracket and pivot on
inside 90-degree corner
Square post with ALX corner bracket and pivot on outside 90-degree corner
Square post with ALX left and right brackets and pivot on inside 90-degree corner
Square posts on non 90-degree split angles can use left/right top rail brackets (shown at left) or a flange-
mount handrail bracket (shown above)
Transitioning from top rail to stair rail is accomplished with two pivots connected with
a male joiner or short piece of rail pipe.Optionally, you may terminate the top rail with
an end cap then install separate stair rail at the desired height.
NO representation is given that your particular application of these products complies with relevant building codes. All products installed without a top rail DO NOT comply with the USA IRC test report provided by Intertek. Therefore, consult with professionals AND local building officials before starting to ensure compliance in your area. The consumer or contrac-tor should take all necessary steps to ensure the safety of all involved in installation of the project, including, but not limited to use of safety glasses, work gloves and safety shoes. NO member of Liv Building Products, or Invisirail shall be liable for any loss, damage or personal injury due to the improper installation of products, or failure to use all items as per the USA-IRC test report . IN the unlikely event of any loss, damage or injury, the total aggregate liabilities will be limited to the retail purchase price of the products.
GENERAL INFORMATION
Only install the outer half of connectors to posts. The remaining half gets installed with glass panel.
Glass panels come with two top holes and two bottom notches. Four connector pins should be installed to secure glass to posts (minimum 1 per side must be used.)
Each connector uses a 1/16” backing plate.
InvisiPost: Connector to Connector
Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.
Put the bolt through the connector, backing plate (provided in connector packs), post, back-ing plate and connector. Thread the bolt through the nut on the other side of the connector.
Make sure that connectors are perfectly vertical!
InvisiPost: Connector to Universal Angle Bracket
Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.
STAINLESS STEEL GLASS CONNECTOR INSTALLATION
5/16” X1 1/2” bolt
5/16” X 1” bolt
connector pin
Disassemble prior to installation
12
Put the bolt through the connector, backing plate (provided in connector packs), post and thread into Universal angle Bracket on the other side.
InvisiPost: Universal Angle Bracketto Universal Angle Bracket
Disassemble the brackets by taking out the lock-ing pin and hinge screw.
Make sure you have both a threaded and a non-threaded Universal angle Bracket.
Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.
Put the bolt through the non-threaded bracket, post and thread into Universal angle Bracket on the other side.
InvisiPost: End post with Connector
Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.
Put the bolt through the connector, backing plate, post and into the acorn nut provided..
5/16” X 1” bolt
5/32” or 4mmhex key
5/16” X 1” bolt
13
InvisiPost: End post with Universal Angle Bracket (UAB)
Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Connector to UAB: Thread a 5/16” X 1/2” bolt through the connector into the swivel por-tion of the bracket until tight.
UAB to Post: Thread a 5/16” X 1” bolt through bracket, post and into the acorn nut provided.
VISTA (ALUMINUM) POST ANDWOOD POST CONNECTOR INSTALLATION
If using VISTA posts, Aluminium posts, 4” x 4” wood posts, or 6” x 6” wood posts, refer to the INVISIRAIL BOLT CHART. Check your post layout diagram to see if you must add spacers.
Straight-Run Connector
Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use InvisiRail Template to locate exactly where connectors should go.
Use hardware provided to attach connector to post (stainless self-tapping lags for aluminum posts or wood screws for wood posts.)
Do not over-tighten lags, causing stripping.
Re-assemble bracket using 5/32” or 4mm
hex key
Bottom position forstainless connectors
Middle hole position for bottom Lite 10 connectors
Template for positioning connectors on VISTA posts & square aluminum or wood posts
For wood posts flip template upside down and place at
base of post on deck surface.
Top position for stainless steel connectors or middle hole position for top Lite 10connectors
14
Universal Angle Bracket
Disassemble the brackets by taking out the locking pin and hinge screw.
Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)
Use InvisiRail Template to locate exactly where connectors should go.
Use hardware provided to attach Universal angle Bracket to post (stainless self-tapping lags for Vista/aluminum posts or wood screws for wood posts.)
Once the hinge is fastened to the post, reassemble bracket and attach glass connector.
15
Invisirail with 1 5/8” diameter stainless steel top rail is International Residency Code (IRC) compliant
White Vista posts with Lite 10 connectors
LITE 10 NYLON GLASS CONNECTOR INSTALLATIONLite 10 connectors are for use with Vista (aluminum) and wood posts. They are not designed for use with InvisiPosts.
Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.) Use InvisiRail Template to locate exactly where connectors should go.
Disassemble the top connector by backing out the nylon retaining pin and sliding off the splined part.
Use hardware provided to attach connector to post (stainless self-tapping screws for Vista / aluminum posts or wood screws for wood posts.) Do not over-tighten tapping screws, causing stripping.
ensure connectors are as parallel as possible to the edge of the post.
Install the open side of the top connector facing towards deck for easier glass installation.
45 degreeanglebracketwith connector
Lite 10 Angle Bracket
Use InvisiRail Template to locate exactly where angle brackets should go.
Mark the bottom edge location of both top and bottom connectors. Bottom mark should be 3 1/4” above flange base. Top mark should be 38 15/16” above flange base.
fasten the 45 degree adaptor to the post with the mark at the bottom of the 45 degree adap-tor.
Using #8 x 1” wood screws (not included) screw the lite 10 connector to the 45 degree angle adaptor.
Mark for angle brackets
16
Stainless Steel Connectors
Use two short pieces of 2X4’s or 4X4’s, sitting on edge of the deck between the posts, to support the glass panels while installing.
Door shims help with fine height adjustments. Connector pins need to be aligned with holes/notches in the glass.
locate correct glass panel to be installed (all panels are labeled.)
Carefully pick up panel and set into position with notches in glass at the bottom.
fasten top connectors first. Place pin through glass and slide remaining connector half into position. If required, shim panel until pin is positioned horizontally, aiding in alignment of connector halves.
Tighten screws enough to hold connectors together but not squeeze tightly on glass.
Once completed, check that all connectors are parallel to each other and tighten screws completely.
GLASS PANEL INSTALLATION
Lite 10 Nylon Connectors
locate correct glass panel to be installed (all panels are labeled.)
Carefully pick up panel and set into position above bottom connectors (notches in glass should be at the bottom) and push glass down into connector until it bottoms.
Take top connector half and slide it into position, then screw pin back in.
If pin does not screw in easily make sure there are no alignment issues. Possible sources of error are: out of plumb posts, posts not set at correct dimension, deck surface not level, connectors not located correctly.
If the connector halves do not slide easily onto installed sections, confirm that the connector has not been over tightened - this would cause misalignment of the two halves.
The back half of connector must be completely flush with the front half to ensure the pin is in the holes in both halves of the connector.
Once the pin is perfectly aligned, completely tighten screws.
17
STAIR GLASS and CUSTOM GLASS Stair Glass
Stair glass for InvisiRail is always custom cut and takes 3-4 weeks for production.
Each piece of stair glass will require a template.
Please ensure accuracy as your glass will be made to the exact size/shape of your template.
Install posts in positions indicated on your post/panel layout diagram, ensuring that they are completely plumb.
(TIP: Use 2” wood screws with washers when locating the stair posts for templating. When glass panels come back you can easily mi-cro-adjust post positions to accommodate glass connection. Once stair glass is installed, switch out the 2” wood screws one by one with the supplied gRKs.)
attach glass connectors to your posts.
Custom Horizontal Glass
Set posts in desired locations, ensuring that they are completely plumb.
Measure from inside post to inside post.
If there are any angled sections, the angle bracket must be installed and measurement must be taken from the face of the angle bracket.
On your order it must be indicated if the measurement was taken from inside posts or face of angle bracket anD the type of glass connectors used (stainless steel or lite 10.)
Use the Custom glass Order form at the back of this manual to complete your order.
Use the InvisiRail cardboard template/s provided to make a template of the exact size and shape of the glass desired.
Install the template into glass connectors and trace around all four (4) connectors for hole and pin location. Indicate the top/bottom orientation and write your name and return shipping address on each template.
Please include the store name and Invoice Order number (or Purchase Order or Estimate Number, if possible) with your templates.
Customer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone number: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
InvisiRail dealer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping address for glass: .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .fax form to 905-852-5196 or email to sales@invisirail.com
18
InvisiPost -- beside stairs scale 1:1
JOIST
3 1/4” toglass
2” to centre post 1 1/4” to glass
STAIRS
3/8”
11/16” (0.6875”)
INVISIPOST POSITIONING DETAIL DIAGRAMS
RIM JOIST
HOUSEHEADERorENDJOIST
1 5/8” MIN - 3 3/4 MAX to centre post
3 1/4” toglass
3/8”
InvisiPost at house or end of run scale 1:1
3/8” MIN - 2 1/2 MAX to flange
InvisiPost -- inside 90 scale 1:1o
JOIST 2 1/2” to anglebracketor2 5/8”(2.625”) toequivalentcentre post
3 1/4” to glass3 1/4” to glass
1 7/8” to centre post 1 3/8” to glass
3/8”
JOIST
5/8”
1 11/16”(1.6875”)
InvisiPost -- outside 90 scale 1:1o
RIM JOIST
ENDJOIST
3 7/8” toequivalenton centreOR4” toanglebracket
4 9/16” (4.5625”) to centre post
3 1/4” toglass
3 1/4” to glass
3/8”
3 5/16” (3.3125”) to flange base
4 3/8” to post face
19
FASCIA
InvisiPost -- inside 45 split scale 1:1o
3 1/4” to glass
7/16” (0.4375“) to angle bracket or
5/16” (0.3125”) to centre post equivalent
JOIST
3 1/4” to glass
1/8”
FASCIA
InvisiPost -- inside 45 split scale 1:1o
3 1/4” to glass
7/16” (0.4375“) to angle bracket or
5/16” (0.3125”) to centre post equivalent
JOIST
3 1/4” to glass
1/8”
InvisiPost -- inside 45 scale 1:1o
JOIST
3 1/4” to glass
3/8”
3 1/4” to glass
ONCENTRE
5/8”or 3/4” tocentre post equivalent
InvisiPost -- outside 45 scale 1:1o
2 5/8” tocentre post
2” to centre post equivalent
3 1/4” to glass
3/8”
JOIST
3 1/4” to glass
1 3/8”toflangebase
2 7/16”(2.4375”)to postface
2 1/8” to angle bracket
FASCIA
InvisiPost -- inside 90 split scale 1:1o
3 1/4” to glass
JOIST
3 1/4” to glass
3/8”
5/8” to angle bracketor
3/4” to centre post equivalent
5/8” to angle bracket
or3/4” to centre post equivalent
InvisiPost -- outside 90 split scale 1:1o
FASCIA
JOIST
3 1/4” toglass
3 1/4” to glass
1 7/16”
1 7/16”
3 1/16”
5 7/8”to angle bracket or 5 3/4” to centre post equivalent
20
FASCIA
InvisiPost -- inside 45 split scale 1:1o
3 1/4” to glass
7/16” (0.4375“) to angle bracket or
5/16” (0.3125”) to centre post equivalent
JOIST
3 1/4” to glass
1/8”
InvisiPost -- outside 45 split scale 1:1o
1 1/8”
3 1/2” to angle bracketor
3 3/8” to centre post equivalent
JOIST3 1/4” to glass
3 1/4” to glass
InvisiPost -- outside 22.5 split scale 1:1o
3/4”
RIMJOIST
3 1/4” to glass
2 3/4” to angle bracketor
2 5/8” to centre post equivalent
3 1/4” to glass
InvisiPost -- inside 22.5 split scale 1:1o
3/16” RIMJOIST
3 1/4” to glass
1 7/16” (1.4375”) to angle bracketor
1 5/16” (1.3125”) to centre post equivalent
3 1/4” to glass
21
15/32”
7/16”
7/16”
2 1/2”
4 3/4”
1 7/8”
InvisiPost flange base scale 1:1
22
23
ALX post at house or end of run scale 1:1
JOIST
HOUSEHEADEROR ENDJOIST
5 1/8” MAX - 2 3/4” MIN to centre post
1/4” min.
1/4” MIN - 2 5/8” MAX to flange
2 3/4” toglass
JOIST
ALX Post -- outside 45 SPLIT scale 1:1o
2 3/4” to glass
7/16”
2 3/4” to glass
4 3/8” to angle bracket 3 1/8” to centre post equivalent
7/16”
1 3/8”
ALX Post -- outside 22.5 SPLIT scale 1:1o
3 3/4” to anglebracketOR2 1/2” toequivalenton centrepost
3 1/4” to glass
1 3/16”
JOIST3 1/4” to glass
3/4”
3/4”
ALX post -- inside 45 SPLIT scale 1:1o
JOIST
3 1/4” to glass
1 15/16” (1.9375“)to angle bracket
11/16” (.6875”) to centre post equivalent
1/8”
3 1/4” to glass
ALX Post -- inside 22.5 SPLIT scale 1:1o
JOIST
3 1/4” to glass
2 1/2” to angle bracket1 1/4” to centre post equivalent
3/8”
3 1/4” to glass
ALX Post -- inside 22.5 SPLIT scale 1:1o
JOIST
3 1/4” to glass
2 1/2” to angle bracket1 1/4” to centre post equivalent
3/8”
3 1/4” to glass
24
5”
5”
2 1/2”
2 1/2”
21/32”
21/32”
11/32”
ALX post flange base scale 1:1
25
VistaPost -- beside stairs scale 1:1
2 1/2 ” to centre post
STAIRS
JOIST
1 3/8 ”
2 1/2 ” tocentre post
1 3/8 ”
VISTA POST POSITIONING DETAIL DIAGRAMS
VistaPost at house or end of run scale 1:1
JOIST
HOUSEHEADEROR ENDJOIST
4 7/8” MAX - 2 5/8” MIN to centre post
3/8”
3/8” MIN - 2 5/8” MAX to flange
Vista Post -- inside 90 scale 1:1o
JOIST
2 1/2” to glass
1 3/8” to post face
JOIST
1/4”
2 1/2” to glass
1 3/8” to post face
Vista Post -- inside 90 scale 1:1o
JOIST
2 1/2” to glass
1 3/8” to post face
JOIST
1/4”
2 1/2” to glass
1 3/8” to post face
1 1/2”
VistaPost -- outside 90 scale 1:1o
JOIST
JOIST
1 1/2
”
2 5/8” to centre post
3/8”
3/8”
VistaPost -- inside 45 scale 1:1o
JOIST
2 1/2” to glass
1 1/4” to centre post
1/4”
2 1/2” to glass
5/16” (0.3125”)
w/stainless steel connectors
1/8”
or 1 7/16”(1.4375”) forcentre postequivalent
1 13/16” (1.8125”) to angle bracket
or 11/16” (0.6875”) tocentre post equivalent
2 1/2” to glass
1/4”
JOIST
2 1/2” to glass
3 1/4” tocentrepost
1”
VistaPost -- outside 45 scale 1:1o
w/stainless steel connectors
2 1/8”
VistaPost -- inside 45 scale 1:1o
JOIST
2 1/2” to glass
1 9/16”(1.5625”) toouter face
1/4” 2 1/2” to glass
5/8”(0.625”)
w/ Lite 10 connectors
7/16” (0.4375”) tocentre post
or 1 3/4”(1.75”) for
centre postequivalent
1 3/8” (1.375”) to angle bracket
or 1/4” (0.25”) to centre post equivalent
2 1/2” to glass
1/4”
JOIST
2 1/2” to glass
2 1/2” tocentrepost
1/4”
VistaPost -- outside 45 scale 1:1o
w/Lite 10 connectors
1 3/8”(1.375”)
26
FASCIA
InvisiPost -- inside 45 split scale 1:1o
2 1/8” to angle bracket or
1” to centre post equivalent
JOIST
2 1/2” to glass
2 1/2” to glass
FASCIA
InvisiPost -- inside 45 split scale 1:1o
3/4” to angle bracket or ADD
3/8” to centre post equivalent
JOIST
2 1/2” to glass
2 1/2” to glass
Lite 10 connectors
4 1/4” to anglebracket
1 3/8”
1/2”
JOIST
2 1/2” to glass
VistaPost -- outside 45 split scale 1:1o
4 1/4” to angle bracket or 3 1/8” to centre post equivalent
2 1/2” to glass
1/2”
Stainless steel connectors
FASCIA
InvisiPost -- inside 45 split scale 1:1o
3/4” to angle bracket or ADD
3/8” to centre post equivalent
JOIST
2 1/2” to glass
2 1/2” to glass
Lite 10 connectors
FASCIA
InvisiPost -- inside 45 split scale 1:1o
2 1/8” to angle bracket or
1” to centre post equivalent
JOIST
2 1/2” to glass
2 1/2” to glass
1”
JOIST
2 1/2” to glass
VistaPost -- outside 45 split scale 1:1Lite 10 connectors
o
2 13/16” (2.8125“) to angle bracket or 1 11/16” (1.6875”) to centre post equivalent
2 1/2” to glass
4 1/4” to anglebracket
1 3/8”
1/2”
JOIST
2 1/2” to glass
VistaPost -- outside 45 split scale 1:1o
4 1/4” to angle bracket or 3 1/8” to centre post equivalent
2 1/2” to glass
1/2”
Stainless steel connectors
27
1/2”
4 1/2”
4 1/2”
7/16”
1/2”
2 1/4”
2 1/4”
15/32”
7/16”
7/16”
2 1/2”
4 3/4”
1 7/8”
InvisiPost flange base scale 1:1
15/32”
7/16”
7/16”
2 1/2”
4 3/4”
1 7/8”
InvisiPost flange base scale 1:1
Vista Post flange base scale 1:1
28
INVISIPOST FASCIA POSITIONING DETAIL DIAGRAMS
11/16” (0.667”) to angle bracketor
9/16” (0.5625”) to centre post equivalent
fascia-mount InvisiPost - corner scale 1:1
FASCIA
2” to glass
fascia-mount InvisiPost inside 90 scale 1:1
2” toglass
2 3/4” to angle bracket or2 5/8 to centre post equivalent
o
FASCIA
2” to glass
3 1/4” tocentre post
3 1/8” toface of post
2” toflange
2 X 1” spacersbetweenpost andanglebracket
1 1/4” toangle bracketor 1 3/8” tocentre postequivalent
2” toglass
o
FASCIA
2” to glass
1 1/4” tocentre post
1 1/8” topostface
fascia-mount InvisiPost outside 90 scale 1:1 fascia-mount InvisiPost -- inside 45 scale 1:1
o
1 1/2” toangle bracket
or1 3/8” to centre post
equivalent
2” toglass
2 1/8” to centre post
FASCIA
2” toglass
7/8” toflange
29
1/8” to angle bracket or
1/4” to centre post equivalent
fascia-mount InvisiPost -- outside 45 scale 1:1o
2” toglass
1 1/2” to centre post
FASCIA
1/4” toflange
1” spacer betweenpost and angle bracket
2” toglass
1.35”
fascia-mount InvisiPost -- beside stairs scale 1:1
2 3/4” to anglebracket or2 5/8” to
centre post equivalent
2” toglass
3 1/4 ” to centre post
STAIRS
FASCIA
2” to glass
2” to flange
3 1/8” to face of post
30
VISTA POST FASCIA POSITIONING DETAIL DIAGRAMS
1 5/16”(1.3125”)
to face of post
VistaPostfascia-mount corner scale 1:1
FASCIA
1 5/16”(1.3125”)
to face of post
2 7/16”(2.4375”)to centre
post
VistaPost fascia -- inside 90 scale 1:1o
2 3/8” to glass
JOIST
2 3/8” to glass
RIM JOIST
VistaPost fascia-mount outside 45 corner scale 1:1
o
2 7/16”(2.4375”) to centre
post
31
VistaPost fascia -- inside 45 scale 1:1o
1 5/8” to angle bracket2 3/8”
to glass
JOIST
7/8”
w/stainless steel connectors
2 3/8” to glass
3 3/8” to centre post
1 1/2” to equivalent on centre
VistaPost fascia -- inside 45 scale 1:1o
1 5/16” (1.3125”) to angle bracket2 3/8”
to glass
JOIST
w/Lite 10 connectors
2 3/8” to glass
2 1/2” to centre post
3/16” (0.1875”) to equivalent on centre
32
33
Customer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone number: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
InvisiRail dealer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping address for glass: .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
fax form to 905-852-5196 or email to sales@invisirail.com
34
w w w. inv i s i ra i l . com sa les@inv is i ra i l . com To l l f ree 1-888-681-9733
Any ins ta l la t ion or use of the p roduct must be in accordance wi th a l l loca l zon ing and/or bu i ld ing codes . The consumer assumes a l l r i sk and l i ab i l i ty assoc ia ted wi th the ins ta l la t ion or use of th i s p roduct .
Check wi th loca l munic ipa l i t ies fo r bu i ld ing code requ i rement in your a rea be fore ins ta l l ing .