Intermodal waste water treatment modules

Post on 09-Jun-2015

193 views 0 download

Tags:

description

Smell the flowers, not the sewer.

transcript

INTERMODAL WASTE WATER TREATMENT MODULES

WWT plant preinstalled in 20’ or 40’ long used highway containers buried deep upright. No moving parts. Its air pump runs on biogas mostly. Produces clean water from sewer (black-to-white). Digests blood, milk, oil, fracking water, silage and more.

Copyright© 2014 LLC, 2013 All rights reserved.

Smell the flowers, not the sewer.

SANITATION OR INFERNO, THAT IS THE QUESTION …

IS THAT REALLY A QUESTION?

STATE-OF-ART REFERENCE WWT PLANT

Large municipal plants require sizable capital, land and manpower.

MAJOR UNDERTAKING

Months of open pit construction work at extremely high expense.Need to locate far from dwellings. Large plants smell like hell.

SIMPLE BIO-TREATMENT PROCESS

ABOVE GROUND PREFAB UNITS

All require liquid pumpingand frequent maintenance.

DOMESTIC WWT APPLIANCES

Four-step batch processing for 5 to 50 inhabitants.8 hours retention time. $ 500-5,000 uninstalled.

Converts domestic black to grey water.

SIMPLE AEROBIC SEPTIC SYSTEM

COMPLEX PROCESS WITHOUT AGITATION

The proposed process is similar, however without liquid pumping and land backflow.

Black-to-Grey Water WWT Plant

IMPROVED NO-CHEM PLANT PROCESS

Self-contained self-propelling process. Maintenances are years apart.Power generator for air pump runs on harvested bio-gas. Non smelling.

Anaerobic

Aerobic

Inflow Outflow

Primary Secondary Tertiary

Black-to-White Water WWT Plant

MODULAR DESIGN FOR DISTRIBUTED PLANTS

Preinstalled in used

intermodalhighway

containers

Serial coupling in “X” Parallel coupling in “Y”

Continuous flow plant

P = PrimaryS = SecondaryT = Tertiary

UNIQUE NOVEL FEATURES

Venturi scavenging

Galvanic balancing

Aerobic reactor

SPECIAL FEATURES

Anaero

bic

Aero

bic

Blow down inlet and galvanic fix film

UV LightSecondary

Tertiary

Modular and buoyant sub-containers

HOW LARGE IS LARGE?7600 cu.ft (56,850 gal)

40-footer intermodal container (8,380 lbs. empty, $ 3,600 ea.)

SMALLEST UNIT

1370 cu.ft (10,250 gal)

20-footer intermodal container4,850 lbs. empty. Used is OK.

PARALLEL COUPLING

6 PST units up to 18 units

No need power generator and air pump in all units, but in two only.Each is capable to serve all units. One works, the other is for emergency.

Community Aggregate

FACILITY NETWORK

Small city network

Tributary area

Swept area

9-aggregate grid

Saint-Venant’s principle: Local disturbance causes only local effects.Distributed black-to-white WWT is far greener than municipal plants.

SIZING

This picture shows a 1,250 gal septic system being built for a 3 bedroom mobile home in rural area with no extra capacity for silos or a pig farm. It converts black water to grey water only, not suitable for sprinkler irrigation.The 20-footer intermodal container insert--in scale--illustrates the proposedprefabricated alternative black-to-white WWT system with double capacity.

$ 8,000-16,000

$ 4,000-8,000 installed

?

BEST CUSTOMERS

Also pig farms, breweries, silage effluents, produce washing … and more.

HOW BLACK IS THE BLACK WATER?

NO-CHEM WWT Plant

IN OUT

2-4 BOD

Dirtier black water requires more or larger

WWT modules.

MARKET SIZE

Assuming only 1% market capture by 2016 with 1% license fee, the present value of the WWT pending patent No.‘149 is $ 4.7 million, while with a working prototype, which may cost up to $ 21,000 to build and install, that value would be $ 9.3 million.

“Global markets for wastewater treatment technologies to grow to $93 billion in 2016”Source: BCC Research (10%+ annual growth over a decade)

GIVE THEM A REASON TO LOVE THEIR JOB

Public officials happily support green jobs and clean projects. No matters what comes in, what goes out is drinkable water.Nothing is greener than that. It runs on its own methane gas.

CONSTRUCTION

Lower pre-installed containers into ground excavation.Hook up customers on the next day. Monitor remote.The effluent is potable water. It need no field vaults.

For more info contact Dr. Kemeny at 888-588-0999.