GROUP 'C' AND 'D'
ONTARIO BUILDING CODE DATA MATRIX - PART 11 - RENOVATION OF EXISTING BUILDING OBCREFERENCE
11.1 EXISTING BUILDINGCLASSIFICATION:
DESCRIBE EXISTING USE: 11.2.1
CONSTRUCTION INDEX: T 11.2.1.1A
HAZARD INDEX: T 11.2.1.1B
NOT APPLICABLE (NO CHANGE OF MAJOR OCCUPANCY) TO N
11.2ALTERATION TO EXISTINGBUILDING IS:
BASIC RENOVATION 11.3.3.1
EXTENSIVE RENOVATION 11.3.3.2
11.3 REDUCTION IN 11.4.2PERFORMANCE LEVEL: STRUCTURAL: 11.4.2.1NO YES
BY INCREASE IN OCCUPANT LOAD: 11.4.2.2NO YES
BY CHANGE OF MAJOR OCCUPANCY: 11.4.2.3NO YES
PLUMBING: 11.4.2.4NO YES
SEWAGE-SYSTEM: 11.4.2.5NO YES
11.4 COMPENSATING 11.4.3CONSTRUCTION: STRUCTURAL: 11.4.3.2NO YES (EXPLAIN)
INCREASE IN OCCUPANT LOAD: 11.4.3.3NO YES (EXPLAIN)
CHANGE IN MAJOR OCCUPANCY: 11.4.3.4NO YES (EXPLAIN)
PLUMBING: 11.4.3.5NO YES (EXPLAIN)
SEWAGE SYSTEM: 11.4.3.6NO YES (EXPLAIN)
11.5 COMPLIANCE NO 11.5.1ALTERNATIVES PROPOSED: YES (GIVE NUMBER(S))
11.6 ALTERNATIVE NO 11.5.2MEASURES PROPOSED: YES (GIVE NUMBER(S))
2
4
NO. DATE DESCRIPTION
1 01/14/2015 FOR PARTIAL REVIEW - LU
2 01/22/2015 FOR FINAL REVIEW - LU
3 01/23/2015 FOR TENDER
DATE
BROOK MCILROY INC. I 37 CUMBERLAND STREET,SUITE 202 THUNDER BAY, ON P7B 2T4
T. 807 683 8005 F. 416 504 7712
ARCHITECTURE I LANDSCAPE ARCHITECTURE I URBAN DESIGN I PLANNING
SHEET NO.
DRAWN
PROJECT NO.
SHEET TITLE
ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THEARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONSAND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECTS WRITTENPERMISSION. DO NOT SCALE FROM THIS DRAWING. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ATTHE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE CONSULTANT PRIOR TO PROCEEDING WITHTHE WORK.
CLIENT
PROJECT NAME
LakeheadU N I V E R S I T Y
BrookMcIlroy/
1/22
/201
5 4:
39:3
8 PM
V:\2
012\
TB -
12-0
26-L
akeh
ead
Uni
vers
ity -
Arch
Ser
vice
s\12
-026
.13
- Hea
lth &
Cou
nsel
ling
Cen
tre (P
retti
e R
esid
ence
)\B -
Dw
gs +
Imag
es\B
2 D
raw
ings
\B2.
0 R
evit\
12-1
26.1
3 H
ealth
& C
ouns
ellin
g C
entre
(Pre
ttie
Res
iden
ce) -
Jan
14
2015
.rvt
Lakehead University955 Oliver Rd, Thunder Bay, ON
Cover Sheet
12-026.13
VLD
JANUARY 2015
A0
Prettie Health Unit Renovations(PR14-004)
LAKEHEAD UNIVERSITY - ARCH SERVICESPrettie Health Unit Renovations
955 Oliver Road, Thunder Bay, ON P7B 5E1
Lead Consultant:
BrookMcIlroy202-37 Cumberland St. S.
Thunder Bay, Ontario, P7B 2T4www.brookmcilroy.com
t. 807 683 8005 info@brookmcilroy.com
LIST OF DRAWINGS
ARCHITECTURAL DRAWINGS:
MECHANICAL DRAWINGS:
ELECTRICAL DRAWINGS:
A0 Cover SheetA1 Legends, Specifications, & SchedulesA2 Renovation PlanA3 Sections and DetailsA4 Sections and Details
Sub-Consultant:
Profor Engineering Services Ltd.5th F-200 Syndicate Ave S.
Thunder Bay, Ontario, P7E 1C9
M1 Partial Main Floor Plan Demolition and Renovation
M2 Mechanical Specifications, Equipment List, Scope of Work, Sequence of Operations, and Piping
E1 Partial Main Floor Plans Electrical Demolition andRenovation Electrical Legend, Single Line Diagram
E2 Electrical Specifications
ABBREVIATIONS
AFF ABOVE FINISHED FLOORALUM ALUMINUMBF BARRIER FREECL CENTERLINECMU CONCRETE MASONRYUNITCOL COLUMNCONC CONCRETEELEV ELEVATIONEP ELECTRICAL PANELEW EYE WASH STATIONEXIST EXISTINGEXP EXPOSEDFA FIRE ALARMFD FLOOR DRAINFIN FINISHFF FINISHED FACEGA GAUGEGALV GALVANIZEDGL GLASSGYP GYPSUM BOARDHM HOLLOW METALLG LAMINATED GLASSMAT'L MATERIALMAX MAXIMUM
MIN MINIMUMMTL METALN/A NOT APPLICABLENIC NOT IN CONTRACTNTS NOT TO SCALEOC ON CENTERO/H OVER HEADOWSJ OPEN WEB STEEL JOISTPLY PLYWOODPT PRESSURE TREATEDPTD PAINTEDR/W REINFORCED WITHSIM SIMILARSL SEALERSS STAINLESS STEELSTL STEELTEMP TEMPORARYTG TEMPERED GLASST/O TOP OFTYP TYPICALU/S UNDERSIDE OFW/R WASHROOMWD WOODWG WIRED GLASS
XX
AX
XXX
XX
XX
AX
XX
WX
BUILDING SECTION
STRUCTURAL GRID & BUBBLE
ROOM NAME & NUMBER TAG
ELEVATIONS
DOOR NUMBER
INTERIOR/EXTERIOR WALL TYPE TAG
WINDOW/LOUVER TYPE TAG
SYMBOL LEGEND
DETAIL NUMBER
SHEET NUMBER WHEREDETAIL REFERENCE FOUND
EXTERIOR BUILDING ELEVATION
INTERIOR BUILDING ELEVATION
AX XX
AX XX
DETAIL NUMBERSHEET NUMBER WHERE DRAWN
DETAIL NUMBERSHEET NUMBER WHERE DRAWN
Level NameElevation
XXX
Room Name
DETAILS
1 HOUR FIRE SEPARATION
GENERAL NOTES
1. ALL DIMENSIONS TO BE VERIFIED ON SITE
2. DOUBLE STUD AROUND OPENINGS IN EXCESS OF 400m2
3. CONTRACTOR TO COORDINATE ALL MECHANICAL ANDELECTRICAL WORK WITH ARCHITECTURAL.
4. COORDINATE ALL MECHANICAL AND ELECTRICAL SERVICESWITH POURING OF CAST-IN-PLACE CONCRETE.
5. ALL PARTITIONS TO EXTEND TO UNDERSIDE OF TRUSSESUNLESS OTHERWISE NOTED.
6. INTERIOR PARTITION TYPES INDICATE ORDER OFCONSTRUCTION FROM POINT OF ARROW THRU PARTITION.
7. LOCK SETS WILL BE GRADE 1 BY SCHLAGE. KEY WAY INFORMATIONTO BE PROVIDED BY LAKEHEAD UNIVERSITY'S BUILDING MAINTENANCEDEPARTMENT.
NO. DATE DESCRIPTION
1 01/14/2015 FOR PARTIAL REVIEW - LU
2 01/22/2015 FOR FINAL REVIEW - LU
3 01/23/2015 FOR TENDER
KEYING NOTES
1. LOCK SETS WILL BE GRADE 1 BY SCHLAGE. KEY WAY INFORMATION TO BEPROVIDED BY LAKEHEAD UNIVERSITY'S BUILDING MAINTENANCE DEPARTMENT.
DATE
BROOK MCILROY INC. I 37 CUMBERLAND STREET,SUITE 202 THUNDER BAY, ON P7B 2T4
T. 807 683 8005 F. 416 504 7712
ARCHITECTURE I LANDSCAPE ARCHITECTURE I URBAN DESIGN I PLANNING
SHEET NO.
DRAWN
PROJECT NO.
SHEET TITLE
ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THEARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONSAND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECTS WRITTENPERMISSION. DO NOT SCALE FROM THIS DRAWING. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ATTHE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE CONSULTANT PRIOR TO PROCEEDING WITHTHE WORK.
CLIENT
PROJECT NAME
LakeheadU N I V E R S I T Y
BrookMcIlroy/
1/22
/201
5 4:
40:1
4 PM
V:\2
012\
TB -
12-0
26-L
akeh
ead
Uni
vers
ity -
Arch
Ser
vice
s\12
-026
.13
- Hea
lth &
Cou
nsel
ling
Cen
tre (P
retti
e R
esid
ence
)\B -
Dw
gs +
Imag
es\B
2 D
raw
ings
\B2.
0 R
evit\
12-1
26.1
3 H
ealth
& C
ouns
ellin
g C
entre
(Pre
ttie
Res
iden
ce) -
Jan
14
2015
.rvt
Lakehead University955 Oliver Rd, Thunder Bay, ON
Legends, Specifications, &Schedules
12-026.13
VLD
JANUARY 2015
A1
Prettie Health Unit Renovations(PR14-004)
Door And Frame Schedule - New Construction
DoorNo. Room Name
Door
Existing Door New DoorERExit
Hold OpenDevice Keyed Entrance
SupplyLockset
Core Repinnedby Lakehead
University CommentsType104 STAIR DOUBLE Yes No YES SPECIAL #1 AND #2 Yes No105 STAIR SINGLE Yes No YES SPECIAL #1 Yes No ALARM106 CORRIDOR SINGLE Yes No SPECIAL #1 Yes No ALARM111 WAITING AREA DOUBLE Yes No No No INSTALL SURFACE
MOUNTED PADBOLT 1068-6"115 CORRIDOR SINGLE Yes No YES GENERAL CENTRE Yes No115A CORRIDOR SINGLE No Yes YES SPECIAL #1 Yes No116 WAITING AREA DOUBLE Yes No YES SPECIAL #1 Yes No121 HEALTH PROMOTION RM. SINGLE Yes No GC - KEYED AREA 2 No Yes123 HEALTH PROMOTION OFF. SINGLE Yes No GC - KEYED AREA 2 No Yes129 ALLIED HEALTH PROF. SINGLE Yes No GC - KEYED AREA 4 No Yes130 COUNSELLOR OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes131 PSYCHIATRIST SINGLE Yes No GC - KEYED AREA 1 No Yes132 SR. COUNSELLOR OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes133 CLINIC MH ASSESSMENT SINGLE Yes No GC - KEYED AREA 1 No Yes137 DIRTY UTILITY SINGLE Yes No GC - KEYED AREA 1 No Yes138 COUNSELLOR OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes139 TRIAGE SINGLE Yes No GC - KEYED AREA 1 No Yes140 COUNSELLOR OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes141 OBSERVATION RM. SINGLE Yes No GC - KEYED AREA 1 No Yes142 GROUP ACTIVITY RM. SINGLE Yes No GC - KEYED AREA 3 No Yes142A GROUP ACTIVITY RM. SINGLE Yes No YES SPECIAL #1 Yes No CONNECTED TO EXISITING
EMERGENCY ALARM.142B GROUP ACTIVITY RM. SINGLE Yes No YES SPECIAL #1 Yes No CONNECTED TO EXISITING
EMERGENCY ALARM.142D No No143 RN OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes144 DEBRIEF / LUNCH SINGLE Yes No GC - KEYED AREA 3 No Yes145 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes146 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes147 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes148 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes149 W/R SINGLE Yes No No No150 DOCTOR'S OFFICE SINGLE Yes No GC - KEYED AREA 1 No Yes151 MED SINGLE Yes No GC - KEYED AREA 5 No Yes152 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes153 SUPPLY SINGLE Yes No GC - KEYED AREA 1 No Yes154 CLINIC EXAM RM. SINGLE Yes No GC - KEYED AREA 1 No Yes155 BILLING / STATS CLERK SINGLE Yes No GC - KEYED AREA 1 No Yes158 W/R SINGLE Yes No No No160 LAB SUPPLY SINGLE Yes No GC - KEYED AREA 1 No Yes162 SR RN SINGLE Yes No GC - KEYED AREA 1 No Yes164 MGR SINGLE Yes No GC - KEYED AREA 1 No Yes167 CORRIDOR SINGLE Yes No No No REMOVE DOOR. SEE
RENOVATION NOTE 12167A CORRIDOR SINGLE Yes Yes Yes No REVERSE DOOR SWING
FOR BARRIER FREEREQUIREMENTS
168A VEST. SINGLE Yes No SPECIAL #1 Yes No POWER DOOR OPERATOR168B VEST. SINGLE Yes No SPECIAL #1 Yes No POWER DOOR OPERATOR169 NIS SINGLE Yes No No No170 W/R SINGLE Yes No No No REVERSE DOOR SWING
FOR BARRIER FREEREQUIREMENTS
171 STAIR SINGLE No Yes SPECIAL #1 Yes No ALARM179 RECEPTION OFFICE SINGLE Yes No SPECIAL #1 Yes NoX104 STAIR DOUBLE Yes No YES No NoX105 STAIR SINGLE Yes No YES No NoX106 STAIR DOUBLE Yes No No No
Room Finish Schedule - New Construction
NO Room Name Sink Floor Lighting WindowsComments
121 HEALTH PROMOTION RM.123 HEALTH PROMOTION OFF.129 ALLIED HEALTH PROF. FILM BOTTOM HALF SEE RENOVAION NOTE R02130 COUNSELLOR OFFICE FILM BOTTOM HALF SEE RENOVAION NOTE R02131 PSYCHIATRIST FILM BOTTOM HALF SEE RENOVAION NOTE R02132 SR. COUNSELLOR OFFICE FILM BOTTOM HALF SEE RENOVAION NOTE R02133 CLINIC MH ASSESSMENT FILM BOTTOM HALF SEE RENOVAION NOTE R02137 DIRTY UTILITY LED138 COUNSELLOR OFFICE FILM BOTTOM HALF SEE RENOVAION NOTE R02139 TRIAGE NEW LED FILM BOTTOM HALF /
FULL WINDOWSEE RENOVAION NOTE R02 & R08
140 COUNSELLOR OFFICE FILM BOTTOM HALF SEE RENOVAION NOTE R02141 OBSERVATION RM. FILM BOTTOM HALF /
FULL WINDOWSEE RENOVAION NOTE R02 & R08
142 GROUP ACTIVITY RM.143 RN OFFICE LED FILM BOTTOM HALF SEE RENOVAION NOTE R02144 DEBRIEF / LUNCH LED145 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF /
FULL WINDOWSEE RENOVAION NOTE R02 & R08
146 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF SEE RENOVAION NOTE R02147 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF /
FULL WINDOWSEE RENOVAION NOTE R02 & R08
148 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF /FULL WINDOW
SEE RENOVAION NOTE R02 & R08
149 W/R150 DOCTOR'S OFFICE LED151 MED NEW152 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF /
FULL WINDOWSEE RENOVAION NOTE R02 & R08
153 SUPPLY154 CLINIC EXAM RM. NEW LED FILM BOTTOM HALF SEE RENOVAION NOTE R02155 BILLING / STATS CLERK158 W/R160 LAB SUPPLY LED162 SR RN164 MGR167 CORRIDOR PAINT WALLS, SEE RENOVATION NOTE R06168 VEST.170 W/R BARRIER FREE179 RECEPTION OFFICE LED FILM BOTTOM HALF INSTALL 2 TELLER OPENINGSX104 STAIRX105 STAIRX106 STAIRX115 CORRIDORX115A CORRIDOR TILEX116 WAITING AREA
08 71 00 HARDWARE
GENERAL
SUBMIT MANUFACTURER’S PRINTED PRODUCTLITERATURE, SPECIFICATIONS AND DATA SHEET INACCORDANCE WITH SECTION [01 33 00 -SUBMITTALS].
SUBMIT SAMPLES IN ACCORDANCE WITH SECTION[01 33 00 SUBMITTALS].
IDENTIFY EACH SAMPLE BY LABEL INDICATINGAPPLICABLE SPECIFICATION PARAGRAPH NUMBER,BRAND NAME AND NUMBER, FINISH AND HARDWAREPACKAGE NUMBER.
AFTER APPROVAL SAMPLES WILL BE RETURNED FORINCORPORATION IN THE WORK.
SUBMIT CONTRACT HARDWARE LIST IN ACCORDANCEWITH SECTION [01 33 00 SUBMITTALS].
INDICATE SPECIFIED HARDWARE, INCLUDING MAKE,MODEL, MATERIAL, FUNCTION, SIZE, FINISH ANDOTHER PERTINENT INFORMATION.
SUBMIT MANUFACTURER’S INSTALLATIONINSTRUCTIONS.
PROVIDE OPERATION AND MAINTENANCE DATA FORDOOR CLOSERS, LOCKSETS, DOOR HOLDERS,ELECTRIFIED HARDWARE AND FIRE EXIT HARDWAREFOR INCORPORATION INTO MANUAL SPECIFIED INSECTION [01 78 23 OPERATION AND MAINTENANCEMANUALS].
QUALITY ASSURANCE
HARDWARE FOR DOORS IN FIRE SEPARATIONS ANDEXIT DOORS CERTIFIED BY A CANADIANCERTIFICATION ORGANIZATION ACCREDITED BYSTANDARDS COUNCIL OF CANADA.
TEST REPORTS: CERTIFIED TEST REPORTS SHOWINGCOMPLIANCE WITH SPECIFIED PERFORMANCECHARACTERISTICS AND PHYSICAL PROPERTIES.
CERTIFICATES: PRODUCT CERTIFICATES SIGNED BYMANUFACTURER CERTIFYING MATERIALS COMPLYWITH SPECIFIED PERFORMANCE CHARACTERISTICSAND CRITERIA AND PHYSICAL REQUIREMENTS.
PRE-INSTALLATION MEETINGS: CONDUCT PRE-INSTALLATION MEETING TO VERIFY PROJECTREQUIREMENTS, MANUFACTURER’S INSTALLATIONINSTRUCTIONS AND MANUFACTURER’S WARRANTYREQUIREMENTS.
DELIVERY, STORAGE, AND HANDLING
DELIVER, STORE, HANDLE AND PROTECT MATERIALSIN ACCORDANCE WITH SECTION [01 60 00 - PRODUCTREQUIREMENTS].
PACKAGE EACH ITEM OF HARDWARE INCLUDINGFASTENINGS, SEPARATELY OR IN LIKE GROUPS OFHARDWARE, LABEL EACH PACKAGE AS TO ITEMDEFINITION AND LOCATION.
STORE FINISHING HARDWARE IN LOCKED, CLEANAND DRY AREA.
MAINTENANCE
PROVIDE MAINTENANCE MATERIALS IN ACCORDANCEWITH SECTION [01 78 23 OPERATION ANDMAINTENANCE MANUALS].
SUPPLY TWO SETS OF WRENCHES FOR DOORCLOSERS, LOCKSETS AND FIRE EXIT HARDWARE.
MATERIAL
HARDWARE ITEMS:
USE THE MANUFACTURER’S AS STATED BELOWWITHOUT ALTERNATIVES FOR SIMILAR ITEMS.
DOOR HARDWARE:
LOCKSETS: SCHLAGE ORIGINAL (NOT OFF-SHORE)WITH GRADE 1 CERTIFICATION, LEVER SETS, 626FINISH.
CYLINDERS: SCHLAGE ORIGINAL FG KEYWAY ZEROPINNED TO BE PROVIDED TO LU FOR PINNING.CONTRACTOR TO MAINTAIN SECURITY WITH THEIROWN CONSTRUCTION CORES THAT WILL BESWAPPED OUT BY LU WITH PINNED CYLINDERS. LUHAS REQUESTED NON REMOVEABLE CORES.
INTERIOR DOORS: SUPPLIED CYLINDERS TO BE 1248TYPE.
EXTERIO DOORS: SUPPLIED CYLINDERS TO "T"KEYAY.
EXIT DEVICES: VON DUPRIN 98.
DOOR CLOSERS: VON DUPRIN 4041.
FASTENINGS
USE ONLY FASTENERS PROVIDED BYMANUFACTURER. FAILURE TO COMPLY MAY VOIDWARRANTIES AND APPLICABLE LICENSED LABELS.
SUPPLY SCREWS, BOLTS, EXPANSION SHIELDS ANDOTHER FASTENING DEVICES REQUIRED FORSATISFACTORY INSTALLATION AND OPERATION OFHARDWARE.
EXPOSED FASTENING DEVICES TO MATCH FINISH OFHARDWARE.
WHERE PULL IS SCHEDULED ON ONE SIDE OF DOORAND PUSH PLATE ON OTHER SIDE, SUPPLYFASTENING DEVICES, AND INSTALL SO PULL CAN BESECURED THROUGH DOOR FROM REVERSE SIDE.
INSTALL PUSH PLATE TO COVER FASTENERS.
USE FASTENERS COMPATIBLE WITH MATERIALTHROUGH WHICH THEY PASS.
KEYING
DOORS, PADLOCKS AND CABINET LOCKS TO BEKEYED AS DIRECTED. PREPARE DETAILED KEYINGSCHEDULE IN CONJUNCTION WITH UNIVERSITYREPRESENTATIVE.
PROVIDE KEYS IN DUPLICATE FOR EVERY LOCK INTHIS CONTRACT.
PROVIDE THREE MASTERKEYS FOR EACH MK ORGMK GROUP.
STAMP KEYING CODE NUMBERS ON KEYS ANDCYLINDERS.
PROVIDE CONSTRUCTION CORES.
PROVIDE ALL PERMANENT CORES AND KEYS TOUNIVERSITY REPRESENTATIVE.
INSTALLATION
COMPLIANCE: COMPLY WITH MANUFACTURER’SWRITTEN DATA, INCLUDING PRODUCT TECHNICALBULLETINS, PRODUCT CATALOGUE INSTALLATIONINSTRUCTIONS, PRODUCT CARTON INSTALLATIONINSTRUCTIONS, AND DATA SHEETS.
FURNISH METAL DOOR AND FRAMEMANUFACTURERS WITH COMPLETE INSTRUCTIONSAND TEMPLATES FOR PREPARATION OF THEIRWORK TO RECEIVE HARDWARE.
FURNISH MANUFACTURERS’ INSTRUCTIONS FORPROPER INSTALLATION OF EACH HARDWARECOMPONENT.
INSTALL HARDWARE TO STANDARD HARDWARELOCATION DIMENSIONS IN ACCORDANCE WITHCANADIAN METRIC GUIDE FOR STEEL DOORS ANDFRAMES (MODULAR CONSTRUCTION) PREPAREDBY CANADIAN STEEL DOOR AND FRAMEMANUFACTURERS’ ASSOCIATION.
WHERE DOOR STOP CONTACTS DOOR PULLS,MOUNT STOP TO STRIKE BOTTOM OF PULL.INSTALL KEY CONTROL CABINET.
USE OF “QUICK” TYPE FASTENERS, UNLESSSPECIFICALLY SUPPLIED BY MANUFACTURER, ISUNACCEPTABLE.
REMOVE CONSTRUCTION CORES AND LOCKSWHEN DIRECTED BY UNIVERSITYREPRESENTATIVE; INSTALL PERMANENT CORESAND CHECK OPERATION OF LOCKS.
ADJUST DOOR HARDWARE, OPERATORS,CLOSURES AND CONTROLS FOR OPTIMUM,SMOOTH OPERATING CONDITION, SAFETY AND FORWEATHER TIGHT CLOSURE.
LUBRICATE HARDWARE, OPERATING EQUIPMENTAND OTHER MOVING PARTS.
ADJUST DOOR HARDWARE TO PROVIDE TIGHT FITAT CONTACT POINTS WITH FRAMES.
CLEANING
PERFORM CLEANING AFTER INSTALLATION TOREMOVE CONSTRUCTION AND ACCUMULATEDENVIRONMENTAL DIRT.
CLEAN HARDWARE WITH DAMP RAG ANDAPPROVED NON-ABRASIVE CLEANER, AND POLISHHARDWARE IN ACCORDANCE WITHMANUFACTURE’S INSTRUCTIONS.
REMOVE PROTECTIVE MATERIAL FROM HARDWAREITEMS WHERE PRESENT.
UPON COMPLETION OF INSTALLATION, REMOVE
KEYING SYSTEM SETUP AND CABINET:
SET UP KEY CONTROL SYSTEM WITH FILE KEY TAGS,DUPLICATE KEY TAGS, NUMERICAL INDEX,ALPHABETICAL INDEX AND KEY CHANGE INDEX, LABELSHIELDS, CONTROL BOOK AND KEY RECEIPT CARDS.
PLACE FILE KEYS AND DUPLICATE KEYS IN KEYCABINET ON THEIR RESPECTIVE HOOKS.LOCK KEY CABINET AND TURN OVER KEY TOUNIVERSITY REPRESENTATIVE.
MAINTENANCE STAFF BRIEFING:
BRIEF MAINTENANCE STAFF REGARDING:
PROPER CARE, CLEANING, AND GENERALMAINTENANCE OF PROJECTS COMPLETE HARDWARE.DESCRIPTION, USE, HANDLING, AND STORAGE OFKEYS.
USE, APPLICATION AND STORAGE OF WRENCHESFOR DOOR CLOSERS, LOCKSETS AND FIRE EXITHARDWARE.
DEMONSTRATE OPERATION, OPERATINGCOMPONENTS, ADJUSTMENT FEATURES, ANDLUBRICATION REQUIREMENTS.
DIVISION 9 - FINISHES
09 21 16 - GYPSUM BOARD
GENERAL
INSTALL WORK TO A LEVEL OF TOLERANCE TO1:1200.
DO NOT APPLY GYPSUM BOARD UNTIL BUCKS,ANCHORS, BLOCKING, SOUND ATTENUATION,ELECTRICAL AND MECHANICAL WORK AREAPPROVED.
APPLY SINGLE/DOUBLE LAYER GYPSUM BOARD TOWOOD OR METAL FURRING OR FRAMING USINGSCREW FASTENERS. MAXIMUM SPACING OFSCREWS 300 MM OC.
SINGLE-LAYER APPLICATION:
APPLY GYPSUM BOARD ON CEILINGS PRIOR TOAPPLICATION OF WALLS IN ACCORDANCE WITHASTM C840.
APPLY GYPSUM BOARD VERTICALLY ORHORIZONTALLY, PROVIDING SHEET LENGTHS THATWILL MINIMIZE END JOINTS.
DOUBLE LAYER APPLICATION:
INSTALL GYPSUM BOARD FOR BASE LAYER ANDEXPOSED GYPSUM BOARD FOR FACE LAYER.
APPLY BASE LAYER TO CEILINGS PRIOR TO BASELAYER APPLICATION ON WALLS; APPLY FACELAYERS IN SAME SEQUENCE. OFFSET JOINTSBETWEEN LAYERS AT LEAST 250 MM.
APPLY BASE LAYERS AT RIGHT ANGLES TOSUPPORTS UNLESS OTHERWISE INDICATED.
APPLY BASE LAYER ON WALLS AND FACE LAYERSVERTICALLY WITH JOINTS OF BASE LAYER OVERSUPPORTS AND FACE LAYER JOINTS OFFSET ATLEAST 250 MM WITH BASE LAYER JOINTS.
APPLY 12 MM DIAMETER BEAD OF ACOUSTICSEALANT CONTINUOUSLY AROUND PERIPHERY OFEACH FACE OF PARTITIONING TO SEAL GYPSUMBOARD/STRUCTURE JUNCTION WHEREPARTITIONS BUTT AGAINST FIXED BUILDINGCOMPONENTS. SEAL FULL PERIMETER OF CUT-OUTS AROUND ELECTRICAL BOXES, DUCTS, INPARTITIONS WHERE PERIMETER SEALED WITHACOUSTIC SEALANT.
INSTALL GYPSUM BOARD WITH FACE SIDE OUT.DO NOT INSTALL DAMAGED OR DAMP BOARDS.
LOCATE EDGE OR END JOINTS OVER SUPPORTS.STAGGER VERTICAL JOINTS OVER DIFFERENTSTUDS ON OPPOSITE SIDES OF WALL.
MATERIAL
DRYWALL INSTALLER MINIMUM 5 YRSEXPERIENCE.
BOARD: 1/2" THICK STANDARD, 5/8" THICK TYPE X,4' WIDE x MAXIMUM PRACTICAL LENGTH, ENDSSQUARE CUT, EDGES BEVELED, REFER TODRAWINGS FOR LOCATIONS.
GLASS MAT WATER-RESISTANT GYPSUM BOARD:TO ASTM C1178/C1178M WITH GLASS MATFACINGS, BOTH SIDES, REGULAR AND TYPE X,THICKNESS AS INDICATED ON DRAWINGS, 1200MM WIDE X MAXIMUM PRACTICAL LENGTH, ENDSSQUARE CUT, LONG EDGES TAPERED.
METAL FURRING RUNNERS, HANGERS, TIE WIRES,INSERTS, ANCHORS: TO CSA A82.30 GALVANIZED.
DRYWALL FURRING CHANNELS: 0.5 MM CORETHICKNESS GALVANIZED STEEL CHANNELS FORSCREW ATTACHMENT OF GYPSUM BOARD.
STEEL DRILL SCREWS: TO ASTM 1002.
LAMINATING COMPOUND AS RECOMMENDED BYMANUFACTURER - ASBESTOS FREE.
CASING BEADS, CORNER BEADS, AND EDGE TRIMTO ASTM-C 1047; METAL ZINC COATED; 14 ga BASETHICKNESS, PERFORATED FLANGES, ONE PIECE,UNLESS OTHERWISE SPECIFIED ON DRAWINGS.
SEALANTS IN ACCORDANCE TO CAN/CGSB - 19.21-M87
JOINT COMPOUNDS TO ASTM-C 475, ASBESTOSFREE.
INSTALLATION
ERECT ACCESSORIES STRAIGHT, PLUMB ORLEVEL, RIGID AND AT PROPER PLANE. USE FULLLENGTH PIECES WHERE PRACTICAL. MAKEJOINTS TIGHT, ACCURATELY ALIGNED ANDRIGIDLY SECURED. MITER AND FIT CORNERSACCURATELY, FREE FROM ROUGH EDGES.SECURE AT 150 MM OC USING CONTACTADHESIVE FOR FULL LENGTH.
INSTALL CASING BEADS AROUND PERIMETER OFSUSPENDED CEILINGS.
INSTALL CASING BEADS WHERE GYPSUM BOARDBUTTS AGAINST SURFACES HAVING NO TRIMCONCEALING JUNCTION AND WHERE INDICATED.SEAL JOINTS WITH SEALANT.
INSTALL ACCESS DOORS TO ELECTRICAL ANDMECHANICAL FIXTURES SPECIFIED INRESPECTIVE SECTIONS.RIGIDLY SECURE FRAMES TO FURRING ORFRAMING SYSTEMS.
FINISH FACE PANEL JOINTS AND INTERNALANGLES WITH JOINT SYSTEM CONSISTING OFJOINT COMPOUND, JOINT TAPE AND TAPINGCOMPOUND INSTALLED ACCORDING TOMANUFACTURER'S DIRECTIONS AND FEATHEREDOUT ONTO PANEL FACES.
GYPSUM BOARD FINISH: FINISH GYPSUM BOARDWALLS TO FOLLOWING LEVELS IN ACCORDANCEWITH ASSOCIATION OF THE WALL AND CEILINGINDUSTRIES (AWCI) INTERNATIONALRECOMMENDED SPECIFICATION ON LEVELS OFGYPSUM BOARD FINISH:
LEVELS OF FINISH:
LEVEL 2: EMBED TAPE FOR JOINTS AND INTERIORANGLES IN JOINT COMPOUND AND APPLY ONESEPARATE COAT OF JOINT COMPOUND OVERJOINTS, ANGLES, FASTENER HEADS ANDACCESSORIES; SURFACES FREE OF EXCESSJOINT COMPOUND; TOOL MARKS AND RIDGES AREACCEPTABLE.(FOR USE WHERE WATERRESISTANT GYPSUM BACKING BOARD IS USED ASA SUBSTRATE FOR TILE.)
LEVEL 4: EMBED TAPE FOR JOINTS AND INTERIORANGLES IN JOINT COMPOUND AND APPLY THREESEPARATE COATS OF JOINT COMPOUND OVERJOINTS, ANGLES, FASTENER HEADS ANDACCESSORIES; SURFACES SMOOTH AND FREE OFTOOL MARKS AND RIDGES.
FINISH CORNER BEADS, CONTROL JOINTS ANDTRIM AS REQUIRED WITH TWO COATS OF JOINTCOMPOUND AND ONE COAT OF TAPINGCOMPOUND, FEATHERED OUT ONTO PANELFACES.
FILL SCREW HEAD DEPRESSIONS WITH JOINTAND TAPING COMPOUNDS TO BRING FLUSH WITHADJACENT SURFACE OF GYPSUM BOARD SO ASTO BE INVISIBLE AFTER SURFACE FINISH ISCOMPLETED.
SAND LIGHTLY TO REMOVE BURRED EDGES ANDOTHER IMPERFECTIONS. AVOID SANDINGADJACENT SURFACE OF BOARD.
COMPLETED INSTALLATION TO BE SMOOTH,LEVEL OR PLUMB, FREE FROM WAVES AND OTHERDEFECTS AND READY FOR SURFACE FINISH.
APPLY ONE COAT OF WHITE PRIMER SEALEROVER SURFACE TO BE TEXTURED. WHEN DRYAPPLY TEXTURED FINISH IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS.
MIX JOINT COMPOUND SLIGHTLY THINNER THANFOR JOINT TAPING.
APPLY THIN COAT TO ENTIRE SURFACE USINGTROWEL OR DRYWALL BROADKNIFE TO FILLSURFACE TEXTURE DIFFERENCES, VARIATIONSOR TOOL MARKS.
ALLOW SKIM COAT TO DRY COMPLETELY.REMOVE RIDGES BY LIGHT SANDING OR WIPINGWITH DAMP CLOTH.
PROVIDE PROTECTION THAT ENSURES GYPSUMDRYWALL WORK WILL REMAIN WITHOUT DAMAGEOR DETERIORATION AT TIME OF SUBSTANTIALCOMPLETION.
CONSTRUCT FIRE RATED ASSEMBLIES WHEREINDICATED, SEAL PENETRATIONS
09 91 00 PAINTING
GENERAL
SAND AND DUST BETWEEN EACH COAT TO REMOVEDEFECTS VISIBLE FROM A DISTANCE OF UP TO 1220mm.FINISH BOTTOMS, EDGES, TOPS AND CUT OUTS OFDOORS, AFTER FITTING AS SPECIFIED FOR DOORSURFACES.
REMOVE COVER PLATES ETC BEFORE PAINTING,REPLACE UPON COMPLETION.
FIRE SAFETY REQUIREMENTS
MATERIAL
PAINTING TO THE LATEST EDITION OF THEARCHITECTURAL PAINTING SPECIFICATIONSMANUAL BY THE MASTER PAINTERS INSTITUTE.
OWNER’S REPRESENTATIVE WILL PROVIDE COLOURSCHEDULE AFTER CONTRACT AWARD
INTERIOR PAINTING SYSTEMS
THE FOLLOWING PAINT FORMULAS REQUIRES ATHREE COAT FINISH AS INDICATED IN THE MPIARCHITECTURAL PAINTING SPECIFICATIONSMANUAL.
HIGH GLOSS ENAMEL. COLOR TO BE SELECTED BYCONSULTANT.
RECEPTION AREA
INT 5.3A LATEX G5 FINISH.
PLASTER AND GYPSUM BOARD: GYPSUMWALLBOARD, DRYWALL, “SHEET ROCK TYPEMATERIAL”, ETC AND TEXTURED FINISHES:INT 9.2A LATEX G5 FINISH (OVER LATEX SEALER)FOR WALLS.INT 9.2A LATEX G1 FINISH (OVER LATEX SEALER)FOR CEILINGS.
SUBMIT ONE - FOUR LITER CAN OF EACH TYPE ANDCOLOUR OF FINISH COATING. IDENTIFY COLOURAND PAINT TYPE IN RELATION TO ESTABLISHEDCOLOUR SCHEDULE AND FINISH FORMULA
INSTALLATION
CONTRACTOR SHALL HAVE A MINIMUM OF FIVEYEARS PROVEN SATISFACTORY EXPERIENCE.CONFORM TO LATEST MPI REQUIREMENTS FORINTERIOR PAINTING WORK INCLUDINGPREPARATION AND PRIMING.
PERFORM PREPARATION AND OPERATIONS FORINTERIOR PAINTING IN ACCORDANCE WITH MPIPAINTING SPECIFICATIONS MANUAL EXCEPT WHERESPECIFIED OTHERWISE.
SURFACE PREPARATIONCLEAN AND PREPARE SURFACES IN ACCORDANCEWITH MPI PAINTING SPECIFICATION MANUALREQUIREMENTS.
PREPARE PLASTER AND WALLBOARD SURFACES TOCGSB 85-GP-33M. FILL MINOR CRACKS WITHPLASTER PATCHING COMPOUND.
164
MGR
155
BILLING /STATSCLERK
162
SR RN
160
LABSUPPLY
158
W/R
154
CLINICEXAM RM.
152
CLINICEXAM RM. 150
DOCTOR'SOFFICE
148
CLINICEXAM RM.
146
CLINICEXAM RM.
153
SUPPLY
151
MED
149
W/R
147
CLINICEXAM RM.
145
CLINICEXAM RM.
143
RN OFFICE
141
OBSERVATIONRM.
139
TRIAGE 137
DIRTYUTILITY
140COUNSELLOR
OFFICE
133CLINIC MH
ASSESSMENT
138COUNSELLOR
OFFICE
131PSYCHIATRIST
129
ALLIED
HEALTH
PROF.
132
SR.
COUNSELLOR
OFFICE
130COUNSELLOR
OFFICE
123
HEALTH
PROMOTION
OFF.
121
HEALTH
PROMOTION
RM.
X104STAIR
X105STAIR
X106
STAIR
NOT IN SCOPE
65 m²142
GROUP ACTIVITY RM.
X115CORRIDOR
116
X104
104
123 121
130
132
138
140
133 131
129
115
105
142
144
137
148 146
139141143
150152
145147
154158
149151
160162
153
164
155
106
X106155
164
NIS
NIS
NIS
NIS
NIS
179
RECEPTION
OFFICE
X116
WAITINGAREA
179
X105
R03
R02
R02
R02
R02
R02
R02
R02
R02
R02
5' - 0"
R05
R02
R02
R02
R02 R02
R02
64 m²X115A
CORRIDOR
16 m²144
DEBRIEF / LUNCH
R04
A3
2
1A3
A33
D01
D02
EXISTING CARPET
TO REM
AIN IN CORRIDO
R
ALARM AT
STAIRWELL.
REFER TO
ELEC.
EQ. EQ.
EQ. EQ.
R05EQ. EQ.
R05EQ. EQ.
EQ. EQ.EQ.
R05R05
R07 R07 R07
8' - 8"
SITE VERIFY
16' - 7 1/4"
NOT IN SCOPE
NOT IN SCOPE
INSTALL NEW RAMP AT A 1:20SLOPE. INSTALL EXPANSION JOINTBETWEEN NEW AND EXISTINGCONSTRUCTION. CONTRACTOR TOCONFIRM EXISTING ELEVATIONSFOR RAMP LENGTH.
5' - 5"
R05
R07
EQ.EQ.
R05EQ. EQ.
R07
EQ. R07
R08
R08R08
R08
R08
R08
R09
R09
R09
R09R09
R09R10
R10R10
R10R10
R10
R10 R10 R10 R10
R10 R10 R10
R10 R10 R10
R10
R10 R10
R10 R10 R10 R10 R10R10
R10
5' - 4"
UP
LINE SHOWING EXISTINGCURB.
R08
6' - 1"
R11
R12
R11
R14
167
CORRIDOR
168
VEST.
NIS
170
W/R
168A
168B
R15
170
169
167
115A
142A
142B
R13
R03D02
R05
R10R10
R16
R10 R10 R10
R16 R16
R10 R10 R10 R10
R16
R10
R10
R10
R16
R17
4A4
2A4
1A4
3A4
2A2
A
BC
DE
F
G H
I
J
K
L
M
MOUNT BARRIER FREE PUSHBUTTONSAS PER OBC BARRIER FREE
REQUIREMENTS.
R19
R19
R19 R19
R19 R19R19R19
R06
R06
167A
1' - 1 3/4"
2' -
8 3/
4"
DN
UP
171
111
A23
R06
9 WINDOWS TO BE COVERED IN PRIVACY WINDOW FILM.REFER TO RENOVATION NOTE R02.
R01
246
Dorm Room
1' - 6"R18
5' - 4" 16' - 7 1/4"
INSTALL NEW CONCRETE RAMP AT A 1:20 SLOPE. INSTALLEXPANSION JOINT BETWEEN NEW AND EXISTING CONSTRUCTION.CONTRACTOR TO CONFIRM EXISTING ELEVATIONS FOR RAMPLENGTH.
21' - 11 1/4"
EXISTING FURNITURE INVENTORY
ITEM TYPE WIDTH DEPTH HEIGHT CURRENT LOCATION NEW LOCATION
A RN LOCKER 24" 16" 77" UC1007AK 162
B MED CABINET 30" 12.5" 30.5" CENTRE HALL 151
C MED CABINET 30" 12.5" 30.5" CENTRE HALL 151
D MED CABINET 30" 12.5" 30.5" CENTRE HALL 151
E MED CABINET 30" 12.5" 30.5" CENTRE HALL 151
F OPEN CABINET 36 5/8" 18.25" 84" 1007AK 151
G OPEN CABINET 36 5/8" 18.25" 84" MAIN CENTRE HALL 153
H OPEN CABINET 36 5/8" 18.25" 84" MAIN CENTRE HALL 153
I CLOSED CABINET 36 5/8" 18" 84" 1007A1 153
J LAB CABINETS 30" 13" 30.5" BATHROOM 137
K LAB CABINETS 30" 13" 30.5" BATHROOM 137
L COUNTER 59.25" 15" CENTRE HALL 149
M OPEN CABINET 36 5/8" 18.25" 84" 1007AK 121
NOTE: LAKEHEAD UNIVERSITY TO MOVE EXISTING FURNITURE.
NO. DATE DESCRIPTION
1 01/14/2015 FOR PARTIAL REVIEW - LU
2 01/22/2015 FOR FINAL REVIEW - LU
3 01/23/2015 FOR TENDER
8' -
0"
7' -
0"0'
- 8"3' - 0"2' - 8 3/4" 2' - 8 3/4"
9' - 1 1/2"
RATED HOLLOW METALDOOR AND FRAME.
GEORGIAN WIRED GLASS.2' -
9"0'
- 2" SUPPLY AND INSTALL NEW GRAB BARS TO MEET
BARRIER FREE REQ.
BOBRICK 600 GRAB BAR - FROST CODE 1003 ORAPPROVED EQUAL.
BOBRICK 760 X 760 GRAB BAR - FROST CODE1003 OR EQUAL
NOTE: GRAB BARS TO BE:1. INSTALLED TO RESIST A LOAD OF AT LEAST1.3KN APPLIED HORIZONTALLY OR VERTICALLY2. DIAMETER TO BE BETWEEN 30MM AND 40MM3. HAVE A CLEARANCE OF 30MM TO 40MMFROM THE WALL, AND4. HAVE A SLIP RESISTANT SURFACE
ENSURE ADEQUATE BLOCKING HAS BEENINSTALLED AS PER MANUFACTURERSINSTRUCTIONS
1' -
11 3
/4"
2' -
9 5/
8"
DATE
BROOK MCILROY INC. I 37 CUMBERLAND STREET,SUITE 202 THUNDER BAY, ON P7B 2T4
T. 807 683 8005 F. 416 504 7712
ARCHITECTURE I LANDSCAPE ARCHITECTURE I URBAN DESIGN I PLANNING
SHEET NO.
DRAWN
PROJECT NO.
SHEET TITLE
ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THEARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONSAND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECTS WRITTENPERMISSION. DO NOT SCALE FROM THIS DRAWING. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ATTHE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE CONSULTANT PRIOR TO PROCEEDING WITHTHE WORK.
CLIENT
PROJECT NAME
LakeheadU N I V E R S I T Y
BrookMcIlroy/
1/22
/201
5 4:
53:0
2 PM
V:\2
012\
TB -
12-0
26-L
akeh
ead
Uni
vers
ity -
Arch
Ser
vice
s\12
-026
.13
- Hea
lth &
Cou
nsel
ling
Cen
tre (P
retti
e R
esid
ence
)\B -
Dw
gs +
Imag
es\B
2 D
raw
ings
\B2.
0 R
evit\
12-1
26.1
3 H
ealth
& C
ouns
ellin
g C
entre
(Pre
ttie
Res
iden
ce) -
Jan
14
2015
.rvt
Lakehead University955 Oliver Rd, Thunder Bay, ON
Renovation Plan
12-026.13
VLD
JANUARY 2015
A2
Prettie Health Unit Renovations(PR14-004)
1/8" = 1'-0"1 Renovation Plan
Renovation NotesMark DescriptionR01 PROVIDE AND INSTALL LOW RISE DOOR STOP BY STANLEY OR APPROVED
EQUALR02 ADD 3M FASARA GLASS AND PLASTIC WINDOW FILM OR APPROVED EQUAL TO
BOTTOM HALF OF WINDOW AS PER THE MANUFATURERS INSTALLATIONGUIDE, REVISION C, FEBRUARY 2014.
R03 INSTALL NEW TELLER OPENING INTO EXISTING WALL.R04 INSTALL NEW FLOORING:FORBO MARMOLEUM (2621 DOVE GREY)
HOMOGENOUS SHEET FLOORING AS PER THE MANUFACTURERSCOMMERCIAL INSTALLATION GUIDE OR APPROVED EQUAL. INSTALL 4"RUBBER WALL BASE COLOR TO BE SELECTED BY CONSULTANT
R05 INSTALL NEW SINK, REFER TO MECHANICAL DRAWING M1-PARTIAL MAINFLOOR PLAN DEMOLITION AND RENOVATION PLAN.
R06 PAINT EXISTING BRICK AND BLOCK WALL.R07 REMOVE EXISTING MILLWORK AND ADD NEW 2X6 METAL STUD PLUMBING
WALL WITH 1/2" GWB. PREPARE WALL FOR WALL MOUNTED WASH BASIN.PAINT TO MATCH EXISTING FINISHES.
R08 ADD 3M FASARA GLASS AND PLASTIC WINDOW FILM OR APPROVED EQUAL TOENTIRE WINDOW AS PER THE MANUFATURERS INSTALLATION GUIDE,REVISION C, FEBRUARY 2014.
R09 EXISTING FURNITURE FROM CURRENT MEDICAL CENTRE. LAKEHEADUNIVERSITY TO MOVE FURNITURE FROM EXISITNG SPACE TO NEWRENOVATED SPACE, NIC.
R10 EXISTING MILLWORK TO REMAIN.R11 REMOVE EXISTING MILLWORK PATCH AND MAKE GOOD. CLEAN AFFECTED
BLOCK WALL SURFACE WITH WIRE BRUSH, PATCH AS REQUIRED, GRIND ANDSAND TO MATCH SURFACE OF EXISTING. REMOVE PATCH FROM ANY JOINTSAND GROUT. PAINT AS INDICATED IN RENOVATION R06.
R12 REMOVE EXISTING DOOR AND FRAME. CLEAN AFFECTED BLOCK WALLSURFACE WITH WIRE BRUSH, PATCH AS REQUIRED, GRIND AND SAND TOMATCH SURFACE OF EXISTING. REMOVE PATCH FROM ANY JOINTS ANDGROUT. PAINT AS INDICATED IN RENOVATION R06.
R13 NEW STUD WALL TO MATCH EXISTING. REGISTER NEW WALL WITH EXISTING,PATCH AND MAKE GOOD. MAINTAIN EXISTING FIRE RATINGS.
R14 INSTALL CRUTCH HANGER. LAKEHEAD UNIVERSITY TO CONFIRM LOCATION.R15 REMOVE EXISTING TOILET PARTITIONS. PATCH FLOOR, WALL AND MAKE
GOOD.R16 INSTALL 8" WOOD EXTENSION TO EXISTING COUNTER TOPS. CONTRACTOR
TO CONFIRM SUITABLE LOCATION FOR WOOD SUPPORTS. SEE DRAWING A4.R17 INSTALL NEW 3 1/2" METAL STUD WALL WITH ACOUSTIC BATT INSULATION
AND 1 LAYER OF 15.9 MM TYPE X GYPSUM BOARD ON BOTH SIDES. ALIGNNEW WALL WITH EXISTING SURFACES, PATCH AND MAKE GOOD. MAINTAINEXISTING FIRE RATING.
R18 REMOVE EXISTING MILLWORK AND ADD NEW 2X6 METAL PLUMBING CHASEWITH GWB FINISH. MAINTAIN FIRE RATING AND PAINT TO MATCH EXISTINGFINISH.
R19 INSTALL EXISTING PRIVACY CURTAINS. COORDINATE LOCATION WITH LU
Demolition NotesMark DescriptionD01 REMOVE EXISTING FLOORING AND BASELAYER AND PREPARE SURFACE FOR
INSATLLATION OF FORBO MARMOLEUM (2621 DOVE GREY) HOMOGENOUSSHEET FLOORING AS PER THE MANUFACTURERS COMMERCIALINSTALLATION GUIDE.
D02 CREATE OPENING IN EXISTING WALL AND PREPARE FOR INTSTALLATION OFTELLER WINDOW AS SHOWN ON DRAWING A3 - SECTION AT RECEPTIONAREA. PATCH AND MAKE GOOD ANY AFFECTED SURFACES.
1/8" = 1'-0"4
Partial Second Floor Plan - MechanicalChase Layout
3/8" = 1'-0"2 Ramp Section
1/4" = 1'-0"3 Interior Glazing and Frame 1/4" = 1'-0"5 W/R 170 Interior Elevation
4A3
BARRIER-FREE
7' - 4"
3' - 0" 3' - 0"
5' - 0"
7' - 4"
RO
UG
H O
PEN
ING
4' -
0"
4A3
179
RO
UG
H O
PEN
ING
4' -
6 3/
8"
ROUGH OPEING
3' - 0"
ROUGH OPENING
3' - 0"
OPENING
OPENING
GLAZINGGLAZING
0' - 6" 1' - 7 1/2" 0' - 6"
0' -
8"
BAR
RIE
R F
REE
2' -
9 7/
8"3' -
3"
5' - 0"
0' -
8"
0' - 6" 1' - 7 1/2" 0' - 6"
CLEAR PINE RECEPTION COUNTER AND PRIVACYSCREEN TYP.
STATIONARY TEMPERED 1/4" CLEAR GLASS WINDOWWITH 3/4" CLEAR PINE TRIM TYP.
OPENING IN GLASS WINDOW TYP.
5A3
6A3
CLEAR PINE TRIM TYP.
TRIM BEYOND TYP.
WOOD TRIM (PINE) TYP.
WOOD PRICACY SCREEN BEYOND TYP.
RO
UP H
OPE
NIN
G
4' -
0"
EXISTING WALL BASE
4A3
179
7' - 4"
ROUGH OPENING
3' - 0"
ROUGH OPENING
3' - 0"
3' -
3"
RO
UG
H O
PEN
ING
4' -
0"
OPENING
OPENING
GLAZING GLAZING
RO
UG
H O
PEN
ING
4' -
6 3/
8"2'
- 8
5/8"
5' - 0"
CLEAR PINE TRIM TYP.
STATIONARY TEMPERED 1/4" CLEAR GLASS WINDOWSURROUNDED BY 3/4" CLEAR PINE WOOD FRAME
TYP.
0' -
2"0'
- 0
3/4"
1' - 6"
CLEAR PINE PRIVACY/ RECEPTION COUNTER TYP.
CLEAR PINE PRIVACY/ RECEPTION COUNTERBEYOND.
SOLID WOOD FRAMING ALL AROUND
RECESSED MECHANICAL FASTENER CONCEALED ATBASE TYP.
0' -
0 3/
4"0' - 1 1/2"
WOOD TRIM (PINE) TYP.
CLEAR PINE PRIVACY/ RECEPTION COUNTER TYP.
STATIONARY TEMPERED 1/4" CLEAR GLASS WINDOWSURROUNDED BY 3/4" CLEAR PINE FRAME TYP.
RECESSED MECHANICAL FASTENER CONCEALED AT BASE TYP.
0' -
0 3/
4"
0' -
0 3/
4"
0' - 1 1/2"
SOLID WOOD FRAMING ALL AROUND.
NO. DATE DESCRIPTION
1 01/14/2015 FOR PARTIAL REVIEW - LU
2 01/22/2015 FOR FINAL REVIEW - LU
3 01/23/2015 FOR TENDER
DATE
BROOK MCILROY INC. I 37 CUMBERLAND STREET,SUITE 202 THUNDER BAY, ON P7B 2T4
T. 807 683 8005 F. 416 504 7712
ARCHITECTURE I LANDSCAPE ARCHITECTURE I URBAN DESIGN I PLANNING
SHEET NO.
DRAWN
PROJECT NO.
SHEET TITLE
ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THEARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONSAND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECTS WRITTENPERMISSION. DO NOT SCALE FROM THIS DRAWING. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ATTHE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE CONSULTANT PRIOR TO PROCEEDING WITHTHE WORK.
CLIENT
PROJECT NAME
LakeheadU N I V E R S I T Y
BrookMcIlroy/
1/22
/201
5 4:
41:2
2 PM
V:\2
012\
TB -
12-0
26-L
akeh
ead
Uni
vers
ity -
Arch
Ser
vice
s\12
-026
.13
- Hea
lth &
Cou
nsel
ling
Cen
tre (P
retti
e R
esid
ence
)\B -
Dw
gs +
Imag
es\B
2 D
raw
ings
\B2.
0 R
evit\
12-1
26.1
3 H
ealth
& C
ouns
ellin
g C
entre
(Pre
ttie
Res
iden
ce) -
Jan
14
2015
.rvt
Lakehead University955 Oliver Rd, Thunder Bay, ON
Sections and Details
12-026.13
VLD
JANUARY 2015
A3
Prettie Health Unit Renovations(PR14-004)
1/2" = 1'-0"1 Reception plan 1/2" = 1'-0"2 Elevation Reception Wall
3/4" = 1'-0"4 Section at Reception Opening
1/2" = 1'-0"3 Elevation 1 - a
1 1/2" = 1'-0"5 Reception Detail 1
1 1/2" = 1'-0"6 Reception Detail 2
NEW WOOD TRIM TO MATCH EXISTING TYP.
NEW SOLID WOOD SUPPORT MECHANICALLYFASTENED TO EXISTING COUNTERTOP AND NEWDESK EXTENSION WITH COUNTERSUNK WOODSCREWS AND ADHERED WITH WOOD GLUE TYP.
REMOVE EXISTING WOOD TRIM AND INSTALLNEW TRIM FOR STRENGTH TYP.
INSERT BISCUIT JOINT AT EVERY 6" O.C. TYP.APPLY WOOD GLUE TO EDGE OF EXISTINGCOUNTER TOP AND EDGE OF THE NEWEXTENSION.
NEW COUNTERTOP EXTENSION TO MATCH EXISTINGWOOD TRIM. CONTRACTOR TO VERIFY BESTSUITABLE SUPPORT LOCATION TYP..
EXISTING WOOD CABINET TYP.
WOOD SCREW 6" O.C. TYP.
2' - 9"
0' - 8"2' - 1" 0' - 0 3/4"
3' -
11 1
/2"
0' -
0 3/
4"
0' -
3 1/
2"
NEW WOOD TRIM TO MATCH EXISTING TYP.
NEW SOLID WOOD SUPPORT MECHANICALLY FASTENEDTO EXISTING COUNTERTOP AND NEW DESK EXTENSION
WITH COUNTERSUNK WOOD SCREWS AND ADHEREDWITH WOOD GLUE TYP.
EXISTING WOOD TRIM TYP.
INSERT BISCUIT JOINT AT EVERY 6" O.C. TYP. APPLYWOOD GLUE TO EDGE OF EXISTING COUNTERTOP
AND EDGE OF THE NEW EXTENSION.
NEW COUNTERTOP EXTENSION TO MATCH EXISTINGWOOD TRIM. CONTRACTOR TO VERIFY BEST
SUITABLE SUPPORT LOCATION TYP.
2' - 1" 0' - 8"
0' - 0 3/4"
0' -
0"3'
- 10
3/4
"1' - 9"
0' -
3 1/
2"
EXISTING UPPER CABINET TYP.
WOOD SCREW TYP.
REMOVE EXISTING WOOD TRIM AND INSTALLNEW TRIM FOR STRENGTH TYP.
0' - 8"
NEW WOOD TRIM TO MATCH EXISTING TYP.
NEW SOLID WOOD SUPPORT MECHANICALLY FASTENEDTO EXISTING COUNTERTOP AND NEW DESK EXTENSION
WITH COUNTERSUNK WOOD SCREWS AND ADHEREDWITH WOOD GLUE TYP.
REMOVE EXISTING WOOD TRIM AND INSTALLNEW TRIM FOR STRENGTH TYP.
INSERT BISCUIT JOINT AT EVERY 6" O.C. TYP. APPLYWOOD GLUE TO EDGE OF EXISTING COUNTERTOP
AND EDGE OF THE NEW EXTENSION.
NEW COUNTERTOP EXTENSION TO MATCH EXISTINGWOOD TRIM. CONTRACTOR TO VERIFY BEST
SUITABLE SUPPORT LOCATION TYP..
2' - 1"
3' -
10 3
/4"
1' - 9" 0' -
0 3/
4"
0' - 0 3/4" EXISTING WOOD CABINET TYP.
WOOD SCREW TYP.
0' -
3 1/
2"
NEW WOOD TRIM TO MATCH EXISTING TYP.
NEW SOLID WOOD SUPPORT MECHANICALLYFASTENED TO EXISTING COUNTERTOP AND NEW
DESK EXTENSION WITH COUNTERSUNK WOODSCREWS AND ADHERED WITH WOOD GLUE TYP.
REMOVE EXISTING WOOD TRIM AND INSTALLNEW TRIM FOR STRENGTH TYP.
INSERT BISCUIT JOINT AT EVERY 6" O.C. TYP.APPLY WOOD GLUE TO EDGE OF EXISTING
COUNTER TOP AND EDGE OF THE NEWEXTENSION.
NEW COUNTERTOP EXTENSION TO MATCH EXISTINGWOOD TRIM. CONTRACTOR TO VERIFY BEST SUITABLE
SUPPORT LOCATION TYP..
EXISTING WOOD CABINET TYP.
WOOD SCREW 6" O.C. TYP.
2' - 1"0' - 8"0' - 0 3/4"
0' -
3 1/
2"
1' - 9"
0' - 0 3/4" 2' - 9"
3' -
11 1
/2"
1' - 6"
WOOD DESK EXTENSION TO MATCHEXISTING WOOD TRIM.
EXISTING PLYWOOD AND MELAMINECOUNTERTOP.
EXISTING UPPER CABINET.
NEW WOOD TRIM TO MATCH EXISTING.
INSERT BISCUIT JOINT AT EVERY 6" O.C.TYP. APPLY WOOD GLUE TO EDGE OFEXISTING COUNTER TOP AND EDGE OFTHE NEW EXTENSION.
2' - 1" 0' - 8" 0' - 0 3/4"
2' - 9 3/4"
NEW SOLID WOOD SUPPORTMECHANICALLY FASTENED TO EXISTINGCOUNTERTOP AND NEW DESK EXTENSIONWITH COUNTERSUNK WOOD SCREWSAND ADHERED WITH WOOD GLUE TYP.
6A4
0' - 8" 0' - 0 3/4"
0' -
0 1/
2"
EXISTING PLYWOOD AND MELAMINE COUNTERTOP.
NEW SOLID WOOD SUPPORT MECHANICALLYFASTENED TO EXISTING COUNTERTOP AND NEWDESK EXTENSION WITH COUNTERSUNK WOODSCREWS AND ADHERED WITH WOOD GLUE TYP.
INSERT BISCUIT JOINT AT EVERY 6" O.C. TYP. APPLY WOODGLUE TO EDGE OF EXISTING COUNTER TOP AND EDGE OF THENEW EXTENSION.
COUNTERSUNK WOOD SCREW AT 6" O.C. TYP.
RECESSED WOOD SCREW WITH WOOD PLUG SAND/FINISH TO MATCH TYP.
NEW COUNTERTOP EXTENSION TO MATCH EXISTING WOODTRIM. CONTRACTOR TO VERIFY BEST SUITABLE SUPPORTLOCATION TYP. REGISTER TOP OF EXTENSION WITH EXISTINGMELAMINE COUNTERTOP TYP.
RECESSED WOOD SCREW WITH WOOD FILLER SAND/FINISH TO MATCH TYP.
NO. DATE DESCRIPTION
1 01/14/2015 FOR PARTIAL REVIEW - LU
2 01/22/2015 FOR FINAL REVIEW - LU
DATE
BROOK MCILROY INC. I 37 CUMBERLAND STREET,SUITE 202 THUNDER BAY, ON P7B 2T4
T. 807 683 8005 F. 416 504 7712
ARCHITECTURE I LANDSCAPE ARCHITECTURE I URBAN DESIGN I PLANNING
SHEET NO.
DRAWN
PROJECT NO.
SHEET TITLE
ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THEARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONSAND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECTS WRITTENPERMISSION. DO NOT SCALE FROM THIS DRAWING. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ATTHE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE CONSULTANT PRIOR TO PROCEEDING WITHTHE WORK.
CLIENT
PROJECT NAME
LakeheadU N I V E R S I T Y
BrookMcIlroy/
1/22
/201
5 9:
34:2
4 A
MV
:\201
2\TB
- 12
-026
-Lak
ehea
d U
nive
rsity
- A
rch
Ser
vice
s\12
-026
.13
- Hea
lth &
Cou
nsel
ling
Cen
tre (P
retti
e R
esid
ence
)\B -
Dw
gs +
Imag
es\B
2 D
raw
ings
\B2.
0 R
evit\
12-1
26.1
3 H
ealth
& C
ouns
ellin
g C
entre
(Pre
ttie
Res
iden
ce) -
Jan
14
2015
.rvt
Lakehead University955 Oliver Rd, Thunder Bay, ON
Sections and Details
12-026.13
SMB
JANUARY 2015
A4
Health & Counselling CentreRenovation
1/2" = 1'-0"3 MED Room 151 Desk Extension
1/2" = 1'-0"2 Doctor's Office Room 150 Desk Alteration
1/2" = 1'-0"4 RN Office Room 143 Desk Alteration
1/2" = 1'-0"1 SR RN Room 162 Desk Alteration
1" = 1'-0"5 Section of Typical Countertop Extension 6" = 1'-0"6 Typical Countertop Extension Detail
3 01/23/2015 FOR TENDER
GENERAL PLUMBING NOTES:PARTIAL MAIN FLOOR PLAN - DOMESTIC WATER LAYOUT
PARTIAL MAIN FLOOR PLAN - SANITARY LAYOUT
PARTIAL SECOND FLOOR PLAN - SANITARY LAYOUTPARTIAL MAIN FLOOR PLAN - HVAC RENOVATION
NOTE:
DETAIL1M1
- FIRE DAMPER INSTALLATION
LAKEHEAD UNIVERSITY PRETTIE RESIDENCE - KEY PLAN
MECHANICAL SPECIFICATIONSGENERAL
PLUMBING
EQUIPMENT LIST
SCOPE OF WORK
SANITARY ISOMETRIC
ELECTRICAL LEGEND
PARTIAL MAIN FLOOR PLAN - RENOVATION
PARTIAL MAIN FLOOR PLAN - DEMOLITION
SINGLE LINE DIAGRAM - RENOVATION
“ ”
”
”
ELECTRICAL SPECIFICATIONS
WIRING METHODS
GROUNDING
LIGHTING
”
POWER AND CONTROL
DOOR HOLD OPEN DEVICE
VOICCE/DATA
PANIC ALARM