Post on 17-Jan-2016
transcript
NCSX
B. Stratton
May 13, 2005
Modular Coil Winding Dimensional Control Plan
Peer Review
NCSX
2
Thanks
• This plan is the result of much useful input from: M. Anderson, S. Anderson, A. Brooks, J. Chrzanowski, M. Cole, P. J. Fogarty, M. Hause, P. Heitzenroeder, B. Kearns, B. Nelson, S. Raftopoulos, W. Reiersen, F. Terlitz, D. Williamson, and M. Zarnstorff
NCSX
3
Charge
• Is the overall structure of the plan adequate to ensure good dimensional control of the coil windings?
• Is a trail winding needed in order to achieve good dimensional control? If so, is a trial winding needed on the first production winding form, or on the first winding form of each type? Why?
NCSX
4
Outline
• Assumptions behind dimensional control plan• Dimensional control steps from start to finish of winding process
– These will form the basis for procedures
• Justification for trial winding
NCSX
5
Assumptions
• Strategy: wind “into the box” without shims and with an extra turn (compared to original plan) for each coil type– Type A and B coils will have 11 turns and type C coils will have 10
turns
– Twisted racetrack (TRC) coil experience shows that compression required to fit in extra turn is achievable
– Preset side clamps to positions chosen to achieve desired height of completed winding pack
– Adjust height and width of completed winding pack to place the current center of the coil at the design location
• This strategy assumes uniform compression of the winding pack during winding and adjustment to achieve the correct overall current center of the coil– We will see if this is a valid assumption when the TRC is cut up
NCSX
6
Winding dimensional control plan-1
• Written for first winding of each coil type (either trial winding or production winding)
– Measurement steps that could be eliminated on subsequent windings of a given type are in green
– Areas requiring further work are in blue– Problem areas are in red
1. Mount winding form to support ring and install in Station 1
2. Mount measurement monuments to inside surface of winding form
• Prefer conical seats over tooling balls: quicker and more reliable to measure
• Preferable to have vendor install some monuments on inside and outside of winding form
• S. Raftopoulos has designed two types of “pucks” that can be welded on at PPPL: one with a conical seat and the other with a ¼” hole for laser tracker monuments
• Need to finalize number of monuments, their locations, and which ones will be supplied by vendor
NCSX
7
Measurement monument locations
Conical seatsdistributed around the winding form in this area;6-8 seats on both sides of TVendor supplied or PPPL installed
Precision ¼” holes on bothflange edges, 6-8 holes per flangeVendor supplied
NCSX
8
Winding dimensional control plan-2
3. Set up Romer arm and check calibration against NIST-traceable standard
4. Make point-cloud measurements of machined winding surfaces, flange surfaces, and flange bolt holes
• Can Romer arm reach both sides of winding form from one location? Probably OK for type C coil. Will make CAD model of arm to determine this for all three coil types.
5. Fit CAD model of winding form to point-cloud data6. Measure monuments and incorporate them into CAD model7. Are our measurements consistent with vendor-supplied data?8. Re-measure monuments9. Measure winding surfaces in same pattern as will be used for
measurements taken during coil winding. Necessary to determine component stack up from measurements during winding. Use same pattern as on TRC. Make a measurement fixture that can be installed at each clamp position to define these measurement points.
NCSX
9
Measurement pattern
...Clamp1
Clamp2
Clamp3
Block1
Block2
Point Groups1 2 3
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Point Groups1 2 3
Sim1
Shim2
Shim3
Block 1 between Clamps 1 & 2Similar pattern on sides of winding pack
MeasurementPoints
Winding Direction
Outside
Tee Side
A. Brooks
NCSX
10
TRC Side B: Clamp Location Numbering Scheme
1 2 3
14
13
4
50
30
1110
98765
20
40
12
35
25
15
45
16
17
18
19
A. Brooks
NCSX
11
Winding dimensional control plan-3
10. Re-measure monuments11. Based on our measurements and vendor’s measurements,
are winding surfaces within tolerance? If not, two cases:a. If deviations are smaller than reasonable range of adjustment of
winding pack (<±0.080”) do nothing at this point. Compensate for deviations later during setting of side clamps.
b. If deviations are larger than range of adjustment of winding pack, shim low places to improve uniformity. Use glass cloth tape underneath chill plates to shim.
12. Install clamp studs13. Clean and mold release winding form14. Install winding clamps and lead blocks15. Install cladding, minimizing glue thickness between cladding
and winding surfaces. Bend cladding tabs individually to ensure that cladding conforms well to winding surfaces
16. Measure cladding surfaces on base and septum using standard pattern. Check that dimensions are consistent with winding surface measurements and cladding thickness (0.040”) plus any shims
NCSX
12
Winding dimensional control plan-4
17. Move winding form to station 2 or 4.(delete 3)18. Install ground wrap, trimming as needed in bends to achieve
uniform thickness.19. Measure winding surfaces on top of compressed ground wrap
using standard pattern. Check that dimensions add up to nominal thickness of cladding and compressed ground wrap plus any shims.
• Cladding: 0.040”• Compressed ground wrap: 0.045”-0.010”=0.035”• Total buildup: 0.075”
20. Measure cross sectional dimensions of conductor under gentle compression for spools that will be used to wind side A. Use these conductor dimensions in subsequent prediction of desired winding pack dimensions. Fit set of calipers with wide jaws for this measurement.
NCSX
13
21. For side A, set side clamps parallel to septum at desired width of winding pack using gauge blocks. Use washers to shim side clamps.
a. Where winding surfaces are within tolerance (<± 0.010”) set side clamps to measured width of four compressed conductors adjusted by TRC experience to make predicted height of winding pack correct. On TRC, final height of pack was low compared to expected value in straight sections and it was high in some regions of high torsion/curvature. Use A. Brook’s fit to TRC side A layer 10 height measurements to predict clamp settings.
b. Where winding surfaces are out of tolerance (>±0.010”) set side clamps to positions calculated using expressions in section 1 of M. Zarnstorff’s memo, plus prediction based on fit to TRC side A layer 10 height measurements. Note: these expressions assume that the winding form septum surfaces are straight, perpendicular to the base, and in the desired orientation. More general expressions are needed if these conditions are not satisfied, e. g., if the septum is tilted or if the T is rotated.
Winding dimensional control plan-5
NCSX
14
Best Fit of TRC side A height using layer 10-base measurements before adjustment
Multilinear Regression Fit to Side A, Layer 10 Measurements*-0.1316464+0.1900505*ABS(InP)+0.7826169*ABS(OOP)+0.6833918*ABS(Tors)
R^2 = 0.69
-0.2000
-0.1500
-0.1000
-0.0500
0.0000
0.0500
0.1000
0.1500
0 20 40 60 80 100 120 140 160
Poloidal Location
dH
, in
ches Measured
Fit
*As wound, beforefinal adjustments
A. Brooks
InP=in-plane curvature (1/in)OOP=out-of-plane curvature (1/in)Tors=torsion (rad/in)dW=dH*(W/H) can be used to predict initial clamp settings assuming constant cross sectional area of winding pack
NCSX
15
Calculation of side and top clamp settings from M. Zarnstorff’s memo-1
• Assumptions:1. winding form T is straight, perpendicular to the base and in the
desired orientation2. Assumes turns uniformly distributed in winding pack, so that
location of current center is determined by winding pack boundaries
• Covers two cases:1. Positioning the clamps to compensate for deviation of the
winding surfaces from the design CAD model2. How to adjust the clamps where the desired clamp positions can
not be achieved
1 2
x 1 x 2 w 1 w 2 y 1
h 2
y 2
h 1 x1, x2 (y1, y2)=deviation in horizontal (vertical) locations of winding surfaces
w1, w2 (h1, h2)=deviation in horizontal (vertical) surfaces of winding packs
W, H= design width (height) of winding pack
NCSX
16
Calculation of side and top clamp settings from M. Zarnstorff’s memo-2
2211 )( yxxW
Hh
1212 )( yxxW
Hh
2211 )( xyyH
Ww
1212 )( xyyH
Ww
Case 1: Case 2:
)()(~~
1111111 yhWwxHWHHWS
)()(~~
2222222 yhWxwHWHHWS
)(2
1)( 122211 SS
Wyxx
W
Hh
)(2
1)( 121212 SS
Wyxx
W
Hh
)(2
1)( 122211 SS
Hxyy
H
Ww
)(2
1)( 121212 SS
Hxyy
H
Ww
The ~ denotes the achieved values of theheight and width
NCSX
17
21. Continuedc. Make a set of 10-20 gauge blocks that covers the range of
possible settings in 0.010” increments
d. Radius edge of clamps so they conform better to the winding pack in regions of high curvature or torsion
e. Use silicone rubber under pads in these regions
22. Wind side A to complete winding pack, reforming conductor by tamping as was done on TRC.
23. Set top clamps to specific torque value during winding. Value of 35 in-lbs used on TRC was probably too high. Use 30 in-lbs. Use torque wrenches for which this value falls in the middle of the operating range
24. During winding, measure top and sides of first, fourth, and seventh turns using standard measurement pattern. Check that these dimensions are as expected.
Winding dimensional control plan-6
NCSX
18
25. Measure top and sides of completed winding pack using standard measurement pattern
26. Use Romer arm to set top clamps to desired height of winding pack. This will either be the design height in regions where the winding form is within tolerance (step 21a) or the value from section 1 of M. Zarnstorff’s memo (step 21b) in regions where the winding form is out of tolerance. In places where this can not be achieved, get as close as possible without exceeding 30 in-lbs torque on clamps.
27. Measure height and width of completed side A winding pack.
28. Reposition casting in turning fixture to wind side B
29. Repeat steps 20-27 for side B of coil.
Winding dimensional control plan-7
NCSX
19
30. Adjust height and width of both winding packs starting with side A. This adjustment attempts to keep the current center of the coil within tolerance of the design position in places where setting of the top clamps to the calculated values can not be achieved. Work systematically in regions of 3-5 clamps. Start in regions of high torsion/curvature. Need to define a pattern for adjusting each coil type.
a. In these locations, set top and side clamps to values from expressions in section 2 of M. Zarnstorff’s memo using measured height and width of winding pack to evaluate these expressions. Use Romer arm to set top clamps and adjust shims to set side clamps.
b. Do these expression need to be generalized to account for more complex deviations of the winding form from ideal, e. g., tilting of the septum?
c. Measure top and side of side A winding packd. Readjust side A winding pack to put height and width within
±0.10” of predicted values where possible.e. Measure top and side of side A winding pack
Winding dimensional control plan-8
NCSX
20
30. Continuedf. Use expressions in section 2 of M. Zarnstorff’s memo to calculate
adjustments to side B winding pack required to put overall current center of coil at design location. Use measurements of adjusted side A winding pack from step 30e as input.
g. Adjust side B top and side clamps to calculated values.h. Measure top and side of side B winding packi. Readjust side B winding pack to put height and width within
±0.10” of predicted values where possible.j. Measure top and side of side B winding packk. Perform final analysis to make sure design position of current
center of coil is achieved. Use final measurements of both sides as input.
l. If current center position is not satisfactory, repeat adjustment of both sides (steps a through k)
Winding dimensional control plan-9
NCSX
21
31. Perform final measurement of height and width of winding packs after adjustment is complete
32. Use Romer arm to measure positions of top and side clamps after adjustment is complete. Need to define measurement points on clamps.
33. Go around coil, completing ground wrap and installing chill plates in sections of 3-5 clamps each. In each section:
a. Remove minimum number of top and side clamps needed to complete ground wrap and install chill plates on both sides in one section of the coil.
b. Complete ground wrap on both sides of coil, keeping thickness as uniform as possible in top and side clamp locations. Thickness variation elsewhere is OK.
c. Install chill plates, ensuring that they are in good contact with the winding pack, especially in clamp locations
d. Re-install top and side clamps to positions measured in step 31 minus compressed ground wrap thickness plus chill plate thickness. Use Romer arm to set top clamps. Use shims to set side clamps.
Winding dimensional control plan-10
NCSX
22
34. Measure top and sides of chill plates in standard measurement pattern. Check that dimensions are consistent with final measurements of winding packs in step 31 plus thicknesses of compressed ground wrap and chill plates. What tolerance to set on this measurement?
35. Install cooling tubes and solder them in place, removing minimum number of clamps required to work in a given area. Re-install top and side clamps to positions used in step 33d.
36. Attempt to maintain winding pack dimensions while bag mold is installed. We do not yet have satisfactory plan for doing this. The present plan is:
a. Measure surfaces of top and side clamp pads using Romer arm. How to do this? The top pads appear to be accessible with the small Romer arm tip but the side pads are not. Can they be made a little wider to provide a measurement surface?
b. Remove minimum number of clamps necessary to work in a given area.
Winding dimensional control plan-11
NCSX
23
37. Continuedb. Replace top and side clamp Delrin pads with G-11 pads and
install bag mold. Maintain constant bag mold thickness (two half-lap layers) on top of pads. Variation in bag mold thickness elsewhere is OK.
c. Replace clamps.d. Use Romer arm to set top and side clamp pad surfaces to values
determined from measurements in step 36a plus nominal thickness of compressed bag mold and difference between thicknesses of Delrin pads and G-11 pads. Two half-lap layers of bag mold compresses by 0.005” (after initial compression and release) so compression of bag mold should not be a major source of error. Is this reliable?
e. An alternative is to set the top clamps to 30 in-lbs torque instead of trying to compensate for the bag mold thickness. The chill plate and cooling tube structure is reasonably rigid so it will help hold the winding pack in place as clamps are removed to install the bag mold.
38. Complete coil
Winding dimensional control plan-12
NCSX
24
Justification for test winding
• It would be very useful to do a trail winding on the first winding form of each coil type. The lead blocks and chill plates would be installed but the ground wrap would not be installed to save time.
• After the trial winding is complete, adjust the winding packs to put the current center of the coil at the design location. Then measure the positions of the top and side clamps. For the production windings of each coil type, set the side clamps to these positions. Set the top clamps to these positions after winding. This would have several benefits:– The correct amount of conductor would be wound onto the form in
a “relaxed” state. Less deformation of conductors leading to more uniform distribution in winding pack.
– Minimal adjustment (possibly none) of the completed coil would be required. Saves time.
– The six coils of a given type should be very similar to each other
• Drawback: cost and time• Reminder: the first production winding is de facto a trial winding