Post on 24-Jun-2020
transcript
SIMOTION
New functions of version V4.1 SP2
SIMOTION
Usability
Diagnostics
Upgrade
Overview
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Subject to technical changes/improvements.Industry Sector
Page 3/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
V 4.1 SP2 – Overview of the contents
SIMOTION V4.1 SP2 has been available since September 2008.
The most important new functions are as follows:
Improvement of handling with IBN and diagnosticsEasy upgrade: upgrade by USB stick, ...Comparison of the project: fast and detailed detection and compensation of the differences .Interconnection overview: find quickly relations in the object model.Extended download in RUN: technology objects, Motion Tasks …Task Trace: effective fault localization/optimization in the user program.Diagnostics without SCOUT: significant expansion in the SIMOTION web interface.
New functionsNew ST editor: efficient editorunder preparation
C240 PN: new hardware, supported by V4.1 SP2 for the first timeD445-1: new hardware, supported by V4.1 SP2 for the first time
Overview
SIMOTION
Usability
Diagnostics
Upgrade
Overview
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Subject to technical changes/improvements.Industry Sector
Page 5/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
No SCOUT environmentMachine operator
SCOUT environmentMachine producer
SCOUT project
upgrade
Upgrade archive
Createupgrade data
„Simplified upgrading“ (1)
Advantage:
Upgrade can be realized by the final customer’s staff (maintenance staff)
SCOUT is not necessary on site
USB stick MMC/CF
Record on storagemedium
IT Diag
Upgrade
Subject to technical changes/improvements.Industry Sector
Page 6/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Simplified upgrading“ (2)
Task definitionAn upgrade of the machine (with the machine operator) has to be realizedSCOUT or PC are not availableThe customer’s staff (maintenance staff) must be able to do the upgrade
Solution new function „upgrade data“Create upgrade data:
Realization with SCOUT (after making the changes in the project)Upgrade data set (archive) can contain one or several controls or even several projectsUpgrade data contain everything that can be run on SIMOTION, including SINAMICS-Integrated.
Example of the upgrade media:Even possible without SCOUT via external „update program“Media: CF/MMC, USB stick, IT DiagCF/MMC: only the upgrade data of the device – IT Diag, USB stick: all
Upgrade:The CPU to be upgraded already requires a FW version of at least V4.1 SP2CF/MMC: plug in switch on upgrade process is executedIT Diag: upgrade via existing Ethernet/Internet connectionUSB stick: the same USB stick can be used to upgrade all controls being stored in the archiveThe runtime licences remain the same for all variants
Upgrade
Subject to technical changes/improvements.Industry Sector
Page 7/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT environmentMachine producer
SCOUT project
„Simplified upgrading“ (3)
upgrade
USB stick MMC/CFIT Diag
The machine producer can also use directly the new upgrade possibilities by means of SCOUT
Upgrade
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 9/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Load project from the device„Upload in case of missing or not current project “
Upload:
Upload without projectproject is not available on the PU. The whole content of the control (TO‘s, programs, variables) are uploaded
Upload with existing projectThe project is not online consistentUpdate of all objects via „Load to PU“
Individual upload (object-granular)The project is not online consistentAdaptation via project comparison(will be indicated later)
Storing additional data on the deviceFor the upload and the project comparison, additional data have to be stored on thetarget device before realizing the upload.
Advantage:Easy adaptation to the control (consistence)
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 10/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Project comparison
Project comparison:Possible comparisons:
Devices in one common or in different OFFLINE projectsOFFLINE device in a project with real (ONLINE) device
Functions:Display of the differencesconcerning device, TO, program, ….Detailed comparison of source targetCompensation of the differences
Advantage:Quick comparison of two projects with display of the differences (where, what exactly) Quick and safe compensation of differences
Diagnostics
Industry SectorSIMOTIONPage 11/18
Comparison partners
Comparisonattributes
ObjectObject attributes
Adaptation of the object
Detailedadaptation
Subject to technical changes/improvements.Industry Sector
Page 12/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
TO comparison in expert list
Comparison functions are also possible in TO expert list
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 13/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Online Multiuser Operation - light“
Several users are working on the same project on a CPU.Technology objects and sources can be loaded separately.With a project comparison and especially with the possibilities of adaptation, the changes of a colleague can be accepted in your own project status.
Adap
tion
Adap
tion
Schematic representation of the online multiuser operation
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 14/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Interconnection overview
Interconnection overview:Representation of all objectinterconnections on one deviceRepresentation of overlapping object interconnectionsDetailed representation of object interconnection
on the input side andon the output side
Advantage:Schnelle overview der vorhandenen Objekte (TO‘s) und ihrer Beziehungen (Verschaltungen)
Advantage:quick overview of the existingobjects (TO‘s) and their relations to each other(interconnections)
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 15/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Load changes easily“ (1)
Improvement for the download
Expanded download dialog
Separate initialization of data during the download (in the STOP mode)
Download of subsetsAlso usable in the RUN modeCPU without driveTechnology objects even if thesources are not consistentSources even if technologyobjects are not consistentAlso without HW config
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 16/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Load changes easily“ (2)
Control of MotionTasks from SCOUTImportant for download in the RUN modeRunning Motion Tasks cannot be loaded during the RUN modeActive MotionTasks will stop and then restart after the downloadVia device diagnostics -> Task ManagerSelectable in the debug operation
Diagnostics
Subject to technical changes/improvements.Industry Sector
Page 17/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Task Trace“
Task Trace:The sequence of the single tasks and user events (generated by a functioncommand) are represented in a graphConfiguration of the task trace via IT DiagStart of the SIMOTION Task Trace via SCOUT device diagnostics, IT Diagor via user program (system functions)Start of SIMOTION Task Profiler
Via SCOUT device diagnosticsvia IT Diag
Advantages:It becomes easier to understand and to control the interactions of the programs/tasks
Diagnostics
Industry SectorSIMOTIONPage 18/18
–
Subject to technical changes/improvements.Industry Sector
Page 19/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Generate diagnostics data“
Generate diagnostics data:
Reading out diagnostics data for system and application diagnostics Diagnostics data sind
Diagnostics buffer of SIMOTIONDiagnostics buffer of SINAMICS IntegratedQueued SIMOTION TO alarmsRetain data shots of SIMOTION Additional analysis data for the development
Maintenance staff need ”screw driver“ and ”PC“„Screw driver“
operator control action on the CPU diagnostics data on CF/MMC„PC“
diagnostics data from CF/MMC for OEM or for Siemens analysis.
Storing of the diagnostics data can also be started via IT Diag
Advantages:Generation of diagnostics information without SCOUT for a further analysisHW exchange including saving and restoring the retain data without SCOUT
Diagnostics
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 21/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - „New ST editor“ (1)
New Structured Text EditorOffers the present functionality plus new comfort functions :
Automatic indent/outdentLater formatting /Automatic indent (Ctrl+Alt+F8)Zooming (Ctrl+mouse wheel)Indicate pair of parenthesesShow/hide blank character and tabulators Vertical lines for indent stepsUser bookmarksSelect columns
Usability
Subject to technical changes/improvements.Industry Sector
Page 22/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - „New ST editor“ (2)
Auto-completeFor keywords, data types, local variables and constants, POUs, TOs .To be activated via Ctrl+space bar or, with structures, automatically after the input of the point (e.g. axis_1a. +p -> pathsyncmotion)
Folding (show/hide blocks)Usability
Subject to technical changes/improvements.Industry Sector
Page 23/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - Online / Offline View
Display of online- /offline values in TO dialogsColored field shows which values are visible„YELLOW“ Online values of the TO„BUE“ Offline values of the TO
Usability
Subject to technical changes/improvements.Industry Sector
Page 24/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - new assistantsSetting of the brake behavior in case of TO alarm
Usability
Selection of the brake behavior of the axis is realized via an assistent.
Can be applied to SINAMICS S120, MASTERDRIVES and SIMODRIVE drives .
Subject to technical changes/improvements.Industry Sector
Page 25/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - new assistantsPresetting of dynamic values
Usability
The dynamic values of jerk and acceleration are calculated and setby a default setting of velocity and ramp-up time.
Subject to technical changes/improvements.Industry Sector
Page 26/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - Expansion of accessible nodes
Setting of the PU/PC interface is possible directly from the dialogAutomatic setting of the Ethernet interfaceDirect indication of an IP address
If a router was in between, you would not see the deviceLoad project from card and open it
It is possibly necessary to make settings in NetPro to go online
Usability
Subject to technical changes/improvements.Industry Sector
Page 27/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
SCOUT - Further expansions
Variable comments as tool tipComments from variable declaration tables I/O-Var, glob. Var, variables from MCC and LAD/FBD sourcesand POUs(POE = Program Organizations Unit program, FB or FC)
Display as tool tip when it is used in MCC and LAD/FBD POUs
Usability
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 29/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Diagnostics without SCOUT“ – WEB „Service Overview“
WEB „Service overview “:Access via WEB-BrowserIndividual configuration of the displayedTOs and system variablesIdentical functionality as for serviceoverview in SCOUT
Advantage:Diagnostics/analysis without SCOUT Remote access via WWW
SIMOTION IT
Subject to technical changes/improvements.Industry Sector
Page 30/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Diagnostics without SCOUT“ – WEB „status/control VAR“
WEB „status/control VAR“:Access via WEB-BrowserIndividual configuration of the tableAccess to all SIMOTION variablesStatus and control is possible
Advantage:Diagnostics/analysis without SCOUT Remote access via WWW
SIMOTION IT
Subject to technical changes/improvements.Industry Sector
Page 31/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Diagnostics without SCOUT“ – WEB „Trace“
WEB „Trace“:Access via WEB-BrowserIndividual trace configuration (function as in SCOUT) Graphic representation and multiple possibilities of evaluation
Advantage:Diagnostics/analysis and optimizationwithout SCOUT Remote access via WWW
SIMOTION IT
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 33/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Hardware platforms
Controller C240 PN (under preparation)Same performance/memory configuration like C240(i.e. factor 2.5 faster than C230, factor 1.8 faster than D435)PROFINET interface with 3 ports, in addition to the already existing industrial Ethernet interfaceNo analog drive interface, no encoder interfacesSpare parts are not compatible with C240 or C230-2
Hardware
Subject to technical changes/improvements.Industry Sector
Page 34/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Hardware platforms
SIMOTION C240 / C240 PNExpanded user memory:
35 MB User RAM (previously: 25 MB)
SIMOTION PExpanded user memory:
Up to 100 MB User RAM (previously: 24 MB), 28 MB System RAM Settings via Simotion P Control Manager
Hardware
Subject to technical changes/improvements.Industry Sector
Page 35/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Hardware - Plattformen
SIMOTION DExpanded user memory:
D425/D435: 35 MB User RAM (previously: 25 MB) D445: 70 MB User RAM (previously: 50 MB)
Own operating memory of 20 MB for Java applicationsIntroduction of the 1 Gigabyte CF card (previously: 512 MB)
Has been delivered since 05/08, applicable for all FW versionsWith V4.1 SP2, 1 GB can be used
With older FW versions, 512 MB can be usedEntries for SINAMICS diagnostics buffer are added at the end of the SIMOTION diagnostics buffer.
Hardware
Subject to technical changes/improvements.Industry Sector
Page 36/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Hardware - Plattformen
SIMOTION DNew Control Unit D445-1 (under preparation)
Factor 1.3 faster compared with D445 Double fan module for higher availability of the D445-1 Same interfaces, memory capacity and connection system as D445The D445-1 is upward compatible (from V4.1.2.x on) and can be applied with D445.
Hardware
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 38/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Expansions with SIMOTION DSINAMICS safety functions via PROFIsafe
Release for SINAMICS Safety-Integrated even for D410PROFIsafe with SIMATIC S7 F-CPU and SIMOTION D4x5
Activation of Safety Integrated Extended Functions also via safe communication "PROFIsafe with PROFIBUS" (up to V4.1 HF6, this was only possible via terminal connections of module TM54F).Control (F-logic) is realized via SIMATIC F-CPU, which is connected to PROFIsafe via PROFIBUS (e.g. a CPU 317F-2 DP or also an ET 200S F-CPU with DP master connection module)Maximum number of servo-axes with safety integrated extended functions for each CU:
SIMOTION D4x5: 5Controller extension CX32: 5 (4 with V4.1 HF6)
Safety
Subject to technical changes/improvements.Industry Sector
Page 39/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Expansions with SIMOTION DTopologies PROFIsafe with S7 F-CPU and SIMOTION D4x5
Routing to the integratedSINAMICS S120 drives(already with V4.1 SP1 HF6)
Routing to the externalSINAMICS S120 drives(via second PROFIBUS interface)
Safety
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 41/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Expansions of Motion Control“
Presetting of the control bits in STW1 of the axis telegram by applicationwith _disableAxis() (disableMode:=STATE_MACHINE_CONTROL_BY_APPLICATION) the control bits in STW1.Bit0 - STW1.Bit6 can be set directly via the command _setAxisSTW(), without the TO checking the correctness regarding the PROFIdrive Profile state machinee.g, to stop large drives with closed brake in a remagnetized state and to restart them quickly after the releaseFor further information, please refer to the documentation basis functions and system functions_TP_referencelist
Control bits in STW of the CU telegram by applicationAccess function _setDriveObjectSTW to control word of tel. 39x (DO1), analogous to the access functions with axis TO .You can set those bits in the STW1_device of telegram 39x that are freely usable or not supported by SIMOTION-RTApplication: e.g. for applicative time synchronistation SIMOTION-SINAMICS For further information, please refer to the documentation basis functions and reference list of the devices
Technology
Subject to technical changes/improvements.Industry Sector
Page 42/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
„Expansions of Motion Control“
Global measuring inputs even on CX32 and CU320/CU310Global measuring inputs (measuring event with time stamp) can also be used on CX32 and S120 (CU320, CU310) in connection with SIMOTION P, C and D.
Technology
SIMOTION
Usability
Diagnostics
Upgrade
Safety
Hardware
SIMOTION IT
Documentation, U&A
Technology
Overview
Subject to technical changes/improvements.Industry Sector
Page 44/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Documentation
Signal flow charts for servo part of the axis TO
Documentation, U&A
Subject to technical changes/improvements.Industry Sector
Page 45/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Documentation
Signal flow charts for servo part of the axis TO
Documentation, U&A
Subject to technical changes/improvements.Industry Sector
Page 46/47SIMOTION V4.1 SP2
Diagnostics
Upgrade
Usability
Overview
SIMOTION IT
Hardware
Safety
Technology
Documentation, U&A
Utilities & Applications
New contents of SIMOTION Utilities & Applications V4.1 SP2new FAQ`s availablee.g. for the CX32 configuration, the configuration of drive-related peripherals, the time synchronization SIMOTION-SINAMCSExpanded scriptsExpanded examples and a new library LDPV1 with importantfunctions for the SINAMICS connection.
Documentation, U&A
Siemens AGIndustry SectorI DT MCFrauenauracher Str. 80D-91056 ErlangenFax:+49-9131-98-1297mailto: applications.erlf@siemens.com
Thank youvery much
You can find further detailed informationIn the documentSimotion_New_Functions_V412.pdf