Next

Post on 11-Jan-2016

28 views 0 download

description

Standard Cliqueur troubleshooting guide Start the slide show then click Next. Next. Home. Standard cliqueur. Symptoms of the problem?. When a cycle is launched the power does not work, the solenoid valve does not click. - PowerPoint PPT Presentation

transcript

Next

Home

Standard Cliqueur troubleshooting guide

Start the slide show then click Next

Standard cliqueur

Home

Symptoms of the problem?

When a cycle is launched the power does not work, the solenoid valve does not click.

When a cycle is started the solenoid valve clicks but the gas does not flow.

The oxygen consumption is too high.

Yes No

Home

Is the red “OUT” indicator light on the timer lit up?

Yes No

Home

Is the green "POWER" light on the timer flashing?

Yes No

Home

Is the timer in "C" mode?

Yes No

Home

Is the supply voltage correct?

(24, 110 or 230V AC depending on the model)

Yes No

Home

Is the equipment connected to the regulator properly?

(sometimes the connection is poor due to oxygenation)

Yes No

Home

Is the bottle open and set to the correct pressure?

Yes No

Home

Remove the pipe from the outlet.

When you begin a cycle, does gas flow freely?

Yes No

Home

Remove the pipe from the diffuser inlet.

When you begin a cycle, does gas flow freely?

Yes No

Home

Remove the valve.

When you begin a cycle, does gas flow freely?

Yes No

Home

Is the valve installed in the circuit?

Check the power supply.

If ok, either the timer or control button is defective. Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Switch the timer to "C" mode then try again.

Did this help to solve your problem?

Yes No

Home

Check that there is no rust on the plug pins, if not consult an electrician.

Did this help to solve your problem?

Yes No

Home

The timer is defective. Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

The solenoid valve or the solenoid valve coil is defective. Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Clean or replace (recommended) the couplings and try again.

Did this help to solve your problem?

Yes No

Home

Set the pressure to 1 or 3 bars depending on use

Try again.

Did this help to solve your problem?

Yes No

Home

The solenoid valve or the solenoid valve coil is defective.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

A pipe is blocked. Replace it.

Did this help to solve your problem?

Yes No

Home

The valve is defective. Replace it.

Did this help to solve your problem?

Yes No

Home

The ceramic element is clogged. Clean or replace it.

Did this help to solve your problem?

Yes No

Home

Replace the valve and try again.

Did this help to solve your problem?

Yes No

Home

Check that there are no leaks in the circuit.

See attached procedure.

Did this help to solve your problem?

Yes No

Home

Thank you for using Vivelys' online help.We hope that we have met your expectations, and are available to help if you need

any further information.

Please do not hesitate to contact us by email or telephone:

+33 (0)4 67 85 68 40sav@vivelys.com

Home

Do you need more help?Were you unable to solve the problem using the online troubleshooting guide?

Please contact our technical support team by email or telephone:

+33 (0)4 67 85 68 40sav@vivelys.com

Home