MTS May 2006MTS May 2006
Innovations 2006
HMI innovations
‹Nr.›
MTS May 2006
Innovations 2006
SBU 1 Industrial enclosures
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 3
Accessories
P. 8
Two-handed operating consoles
• Maximum safety categories are met
• Two safety buttons for each hand
• Thus, hands are on the safety button at all times
• No additional cover is required
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 4
Plastic enclosures KS
• P. 15
• Colour changed to RAL 7035
• The colour of accessories has also changed
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 5
CM accessories
P. 18
• CM gland plates• Optimised dimensions
• "Old" dimensions did not have the "best fit“
• CM and TS cable entry plate• "Only buy what you really need"
• Packs of 1
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 6
CM accessories
P. 21• CM folding lever handle
• Prepared for padlocks• For KESO / KABA• For ASSA
• CM mounting plate slide block• Similar function as the one for TS8• May be reused several times "as a tool"
• CM door stay• Installation without drilling• Spring-mounted• Simply snap into position / snap out
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 7
CM accessories
P. 23
• CM rain canopy / vented roof plate• Reliable protection for outdoor siting
• Water runs off to the rear
• Mounting via the existing holes (eyebolts)
• At the front, with integrated ventilation holes at the top
• May also be used when the enclosure is twisted
• Ventilation holes
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 8
CM accessories
P. 23
• CM divider kits• For swing frame, large
• With and without trim panel
• For enclosure width mm: 600 and 800 mm
• For swing frame, large with trim panel, the 180° hinge may be used
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 9
Comfort Panel
P. 24-34
• New panel / installation depth 113 mm
• Off the shelf:• Operating housing 19" x 7 U x 113 mm
• Keyboard housing 19“ x 3.5 U x 113 mm
• Keyboard housing 19“ x 4 U x 113 mm
• Accessories• USB extension
• Protection category IP 66 / 67
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 10
Quickline panelP. 37
• Cut-out for commercially available Siemens panels
• Cost-efficient solution
• In order to open the door, release the hinge pins
• Interior installation with mounting bracket CP 6205.100
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 11Compact Panel TFT holder
Surfaces
Niches
AccessoriesP. 39
• Pedestal, height-adjustable• Swivel area max. 180°
• Adjustment range 200 mm
• With integral gas pressurised spring for pressure relief during height adjustment
• Assembly:
• Rear: attachment using cage nuts
• Front: via mounting bracket (accessories).
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 12
Accessories
P. 40
Support arm, height adjustable, compact
• For panels and TFTs with 2.5 – 8.5 kg• with VESA 75 cut-out at the top
• Bottom desk clamp for worktops (up to 75 mm thick)
• Adjustment options:• bottom, swivel and tilting
• top, vertically hinged and tilting
• Adaptor for VESA 100 as accessory
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 13
Accessories
P. 46
Housing coupling
• Command panels from an installation depth of 150 mm and IW worktops
• Variant for support arm / pedestal
• 350° rotation range may be locked via clamping levers
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 14
Industrial workstations
P. 49
IW logistic point
• Complete solution for accommodating:• PC
• Printer
• Monitor
• Supply includes:
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 15
Industrial workstations
P. 49
IW logistic point printer cabinet 600 x 900 x 600 mm
• For accommodating • Commercially available printers and desktop PCs
• Designer door prepared for mounting installation modules
• Component shelf, pull-out
P. 49
Paper removal flap• Easy access through integral glazed door
• Installation module with custom-made cut-out as special order, e.g. for label printers
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 16
Industrial workstations
P. 54IW stainless steel operating station• For use in
• Food industry• Pharmacy• Petro-chemistry
P. 55• Stainless steel enclosure for tower PC
• W x H x D: 760 x 760 x 300 mm• Roof with cut-out for:
• CP-S support arm• Keyboard cable• Worktop
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 17
Accessories
P. 55
• Worktop, stainless steel
• WHD: 900 x 38 x 600 mm
• Laminated on both sides with cut-out for CP-S support arm
• Prepared for stainless steel keyboard or solid
P. 55
• Cross member, stainless steel
• To increase stability, the cross member protrudes 120 mm above and behind
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 18
FP housings / enclosures
Available from 2007 on!!!
The regulations are being changed!!!
FP = Fire Protected
Fire-protected housings and enclosures
• Secure escape and rescue paths
• Maintaining the function of:• Elevators
• Emergency power supply
• Extinguishing water
• E.g. public institutions, airports, hospitals, schools, museums, libraries...
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 19
FP housings / enclosures
P. 56 All dimensions without lining!!!• FP-TS8 (W x H x D):
• 800 x 2000 x 600 mm• 800 x 2000 x 500 mm• 800 x 1800 x 400 mm
• FP-CM (W x H x D):• 800 x 1000 x 300 mm• 800 x 1200 x 400 mm
• FP-AE (W x H x D): • 600 x 600 x 210 mm
• Other sizes available on request!
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 20
FP housings / enclosures
P. 56
FP-PL terminal box with function retention
• Function retention: E 30/ E 60/ E 90
• Protection category: IP 54
• 100 x 100 x 50 mm and
• 115 x 115 x 66 mm
FP – KL
• Function retention: E 30
• Protection category: IP 66
• 115 x 115 x 93 mm with and without fused junction
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 21
Stainless steel keyboard housing
P. 51
• 4 dimensions for 1 to 4 command and signalling units 22.5 mm
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 22
AE enclosure
P. 52
Four new dimensions for:• AE stainless steel
• Stainless steel 1.4301 (V2A)
Stainless steel 1.4404 (V2A)• Now 5 dimensions available off the shelf
Accessories:
• Cam lock changed for 1.4404
• New wall bracket in stainless steel
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 23
AE enclosure
P. 53
AE IP 69K stainless steel
• Same dimensions as stainless steel
• 10° roof tilt prevents liquids from accumulating on the roof
• Silicone seal• Temperature-resistant: -60°C to +180°C
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 24
Stainless steel enclosures
Silicone seal for stainless steel enclosures
• Protects better against aggressive cleaning agents and disinfectants
• Seal absorbs almost no water
• Temperature-resistance: -60°C to +180°C
• Also available as special for:• AE stainless steel, single-door • BG stainless steel• KL stainless steel
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 25
TS 8
Also available in WxHxD:
• 600 x 1200 x 500 mm
• 800 x 1200 x 500 mm
• 1200 x 1200 x 500 mm
• Suitable side panels as accessories
TS 8 stainless steel: brushed finish changed from 240 to 400 grain:• Enclosures
• Side panels
• Base/plinth components, front and rear
• Baying cover, top
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 26
Accessories
P. 178
Pressure relief valve
• Protection category IP 66, 68, 69K
• Reduces the formation of condensation
P. 178
Universal key
• With bit adaptor and turning bit:
• Torx 25
• Recessed head (Ph 2)
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 27
Accessories
P. 183• Support rail 65 x 42 mm, unslotted for
enclosure width /depth 400, 500, 600 and 800 mm
P. 183• Support rail for heavy-duty components (up
to 5,000 N / rail)• Suitable for 600 and 800 mm wide
enclosures
P. 182• Attachment for TS punched section with
mounting flange, 17 x 73 mm• when the screw-joint cannot be accessed
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 28
Accessories
P. 50
• TS 180° for dynamic loads• Heavy, dynamic loads
• Heavy equipment installed on the door (up to 900 N)
P. 180
• Protective beam and holder• Alternative to a door in a switch room
• Prevents objects from falling into the open enclosure frame
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 29
Accessories
P. 179
• Sealing frame for through-panel mounting in rear or side panels
• To suit enclosure widths of 600 mm and above
• In depths of 75 and 100 mm
• Mounting plate in a set forward position
• Protection category IP 54 subject to correct mounting
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 30
Accessories
P. 181
Wiring plan pocket
• Sheet steel for TS, CM, ES, PC
• Depth 35 mm
• Plastic, self-adhesive
• Knockouts for optional screw joints
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 31
Accessories
P. 190
Cable conduit
• Two sizes: SW 29 / 50• Connected straight or in a 90° angle
• Holder for correct laying
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 32
Accessories
P. 195
Compact light
• Multifunctional fastening on both sides• Magnet, clip, screws or combinations thereof
• May be positioned flexibly
• Saves power whilst producing more light• 8 watts compare with 14 watts standard/courtesy lights
• 18 watts brighter than 14 watts standard/courtesy lights
• Integral connection cable, 3 m
• Pluggable door-operated switch as accessory
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 33
Accessories
P. 186
Socket strip
• With three sockets, overvoltage protection and interference filter
• Socket inserts twisted by 45°
• Connection socket for front power supply
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 34
Accessories
Flyer
Connector gland
• Sealing frame for connector cut-outs 16/24-pole for 8/10 cables
• No dismantling required when individual cables/leads must be installed/dismantled
• Seals are fastened safely to the cable
• Incl. strain relief
‹Nr.›
MTS May 2006
Innovations 2006
SBU 4 Power distribution
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 36
RiLine60
• 60 mm busbar system
• Flat bar system with integral cross section adaptation: Now also available with base tray technology
• Top-mounting PLS systems: easier to assemble
• Connection adaptor with impressive connection system and a great number of versions
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 37
RiLine60
• Type-tested to EN60439-1
• NEW: GL-approved
• System includes: approx. 130 articles
• Universal CB adaptor up to 630 A
• Innovative component adaptor system with support frame connector
• Protection category IP2x
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 38
RiLine60
• Support frame with push-in trim• Important accessory for replacement
assemblies for RiLine60 Premium adaptors
• Incl. support rail and push-in trim
• New adaptor versions• OM adaptor, 45 mm wide, with AWG10
• OM adaptor, 75mm wide, with AWG6
• Connection angle for CB adaptors• Designed to suit 250 A CB adaptors
• Designed to suit 630 A CB adaptors
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 39
RiLine60 UL design
• New busbar holder with greater creepage distances and clearance• Base tray is a must-have
• Short circuit data are similar to the IEC design
• Top-mounting components are identical with the IEC line• OM / OT adaptors with AWG leads only
• CB adaptor 160 A in specific design
• New connection adaptor for PLS
• Rated data differ sometimes from IEC
• To be approved by June 2006
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 40
298 mm250 mm (250)NH3
298 mm210 mm (210)NH2
298mm184mm (186)NH1
194mm106 mm (115)NH00
HeightWidth (before)Size
RiLine60
• RiLine NH – the new generation of isolators
• Consistent design of all sizesfrom NH00 to NH3
• With tried-and-trusted clamping screw technique
• Simple reversal of the cable outlet at thetop or bottom by rotating the mounting hooks
• Perfectly integrated into the RiLine60 contact hazard concept: IP 2X
• Safe operation, thanks to contact hazard protection
• Lid may be locked
• Available from: 11/06 (NH00+1) and 01/07 (NH2+3)
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 41
Maxi PLS
• Corner connector for Maxi-PLS • For 90° connection for busbar systems in
the roof area
• Available for 1600A / 2000A / 3200A
• Packaging: Packs of 1 set
• Corner bracket for Maxi-PLS• For 90° connection for busbar systems in
the rear area
• Versatile
• Available for 1600A / 2000A / 3200A
• Packaging: Packs of 1 set for each busbar
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 42
Maxi PLS
Maxi PLS–vertical coupling sets 1600 A
• Vertical coupling sets for Maxi-PLS 1600 A for busbar systems in the roof and rear area
• Rittal Maxi-PLS compact infeed• Flexible cable connection bar system,
whatever the enclosure width
• Several adjacent infeeds in one enclosure
• Direct mounting on the punched section without mounting flange or on the mounting plate
• For Maxi-PLS 1600 A / 2000 A busbars
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 43
ISV
• Roof plate for cable entry gland • Roof plate with gland apertures
• In exchange for the standard TS8 roof plate
• Suitable for enclosures with Widths: 600, 850 and 1100 mmDepths: 400 and 600mm
• Solid cable entry gland.• For concealing unused openings
• Inexpensive alternative to the existing gland plates
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 44
Power Engineering V2.0
• New (compared to V1.0)• Corner field• 2200 mm high enclosures• Parts lists can be exported directly into Excel• Automatic text configuration for special
connection kits• Flexible user tool "My Accessories"
• Optimised • PE and neutral conductor configuration• More accessories can be configured (divider
panels, covers, etc.)• Maxi-PLS and ISV can be configured as
separate enclosures in a project.
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 45
Maxi-PLS
• Prototype system with internal division, design 4a • with form subdivision Form 2-4 according
to IEC 2 60439-1
• For rated currents up to 1600 A
• May be used as power distribution system (PCC) and control system (MCC).
• Modular interior installations with system components
• Flat bars or PLS bars may be selected from the RiLine60 program
• Available from October 2006
‹Nr.›
MTS May 2006
Innovations 2006
SBU 3 System climate control
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 47
TopTherm & RiNano
PLUS • RiNano-coated condenser in all cooling units
• Electronic condensate evaporation integrated into all roof-mounted and wall-mounted units with cooling outputs of 1000 watts or greater
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 48
Enclosure cooling during the production of disc brakes
Application: Audi Ingolstadt
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 49
RiNano cooling unit
• SK 3305.100 / 1500 watts• Has been operated since June 2005
• No filter mat
• Has not been serviced so far
• Extreme condition:• Dust
• High ambient temperatures
• High power loss inside the enclosure
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 50
Enclosure cooling during the production of disc brakesApplication: Audi Ingolstadt
• Existing units without RiNano have been used for 5 to 6 years
• The cooling units must serviced regularly to ensure that they operate continuously.
• Filter mats must be replaced every week!
• The picture shows a filter mat after 5 days!
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 51
TopTherm & RiNano
Benefits:
• Clean heat exchangers
• Longer maintenance intervals
• No power drop
• Higher energy efficiency
• Easier to clean
• No filter mats (dry dust)
• Longer downtimes (metal filters for oil-bearing air)
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 52
Condensate management
• Integrated condensate management• Requirements from the automobile industry
• Risk of accidents Puddles
• Specified by the US automotive industry
• RTT cooling unit series with integrated condensate evaporation• For all roof-mounted and wall-mounted units
from 1000 watts on
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 53
Condensate management
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 54
Air/water heat exchangers
New series
• 500 to 5000 watts
• 230 V, 115 V and 400 V, 2~,
• Optionally with basic or comfort controller
• Slimline design
• Comes with all water-carrying parts in V4A -1.4571
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 55
Mounting cut-outs suitable for “mounting” on RTT wall-mounting cooling units
Air/water heat exchangers
‹Nr.›
MTS May 2006
Innovations 2006
SBU 3
Recooling systems
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 57
Recooling systems
• Wall-mounted, 4,000 watts
• RiNano-coated as standard
• Controlled via Microcontroller Box (MCB) • Individual fault messages are processed by the
display and the diagnosis software
‹Nr.›
MTS May 2006
Innovations 2006
SBU 6
Outdoor & fuel cells
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 60
Toptec CR
• 4 dimension variants• W: 600/800 x H:1,200/1,600 x D: 600 mm
• Welded vertical section with roof and bottom (base/plinth integrated) made of V2A stainless steel
• Twin-walled doors and side panels made of zinc-plated sheet steel
• Rain canopy made of aluminium
• Fully spray-finished in RAL 7035
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 61
Toptec CR
• Simple baying, since there is no side roof projection
• Toptec cooling modules may be used
• Lifting eyebolts are not included in the supply. Rain canopy must be dismantled if the unit is transported by crane
• Double side panel at the inside which means that the outer TS8 frame level can only be accessed with difficulty
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 62
• Door stay • Made of round steel, opening range: 90°,
115° or 130°
• More robust than the old version
• Door handle • Swing lever with direct access to the semi-
cylinder
Toptec CR
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 63
• Toptec concrete base/plinth• 600 / 800 mm wide
• 600 mm deep
• Depth stay for Toptec CR• For W: 800 mm D: 600 mm
• Mounted on the inner level
• Assembly kit• In the enclosure depth
• For attaching mounting plates / swing frames
Toptec CR accessories
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 64
Small applications
up to 250 wattsOutdoor UPS
From 3 to 15 kW
Indoor UPS
From 10 to 200 kW
CatalogueProject solution Concept
Fuel cell technology
• 3 different applications and output categories
‹Nr.›
MTS May 2006
Innovations 2006
SBU 5
Rittal Smart Package, racks and accessories
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 66
Rittal Smart Package
• Pre-configured TS8 server racks • 800 mm wide, 42 U, 1000 mm deep
• In different designs for small and medium-sized companies:• Integrated PSM busbar
• 2 kVA or 3 kVA UPS installed
• Different climate control concepts:
• Slotted doors
• Roof-mounted fan
• Wall-mounted cooling unit on the rear door
• With CMC-TC installed in some cases
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 67
TS8/HPC network and server enclosures
Server enclosures, 1200 mm deep,
• 2000 + 2200 mm high
• RAL 7035 / 9005
• Standard mounting angles
HPC (High Power Cooling) enclosures, 1200 mm deep,
• WxH 600 / 800 x 2000 mm
• To be combined with LCP/LCP
• Protection category up to IP 55
• 482.6 mm (19") mounting frame
• Load capacity up to 1000 kg max.
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 68
Accessories
• DK-TS side panels• May be screw-fastened / plugged
• 2000 / 2200 high
• TS roof plate• for cable entry, two-piece
• 600 / 800 mm wide
• Interior installation:• TS punched section with mounting
flange 17 x 73 mm, outer level (notched!)
• DK C rails
• TS cable clamp rails for TS and 482.6 mm (19") mounting frames
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 69
Accessories
• DK stabiliser, pull-out• Load capacity up to 150 kg
• System supports for cable routes• For 800 - 1200 mm deep enclosures
• TS base/plinth in RAL 9005 and 7035• More dimensions
• TS punched section with mounting flange 17 x 73 mm• With slots• for 900, 1000, 1200 mm width /
depth
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 70
Accessories
TS partition
• HxD 2000/2200 x 1000/1200 mm
• For sliding in and partitioning retrospectively, especially in conjunction with climate control components in enclosures suites
• With concealed cut-outs in all corners for routing cables and leads between the enclosures
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 71
Accessories
TS IT glazed door• Aluminium frame section in a new
design• Integrated hinges• 180° opening even when bayed• New, flat handle system• It is possible to conceal the cable
routing to the handle and to the sensorics
• Dimensions• Width: 600 / 800 mm• Height: 800 - 2,200 mm
• Standard glazed door in IT Catalogue 2006!
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 72
Accessories
TS infill panel
• for network enclosure, 800 mm wide
• Installation height: 33, 38, 42, 47 U
• Large cable storing space
• May be combined with large shunting ring
• May be fastened on the vertical frame section, at the inside
• Depth-variable, on the punched section, inside
• Hinged version
• Open/closed action point
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 73
Accessories
• Cable anchor (black)• Size of the shunting ring 1 U / 4 U
• Cranked for mounting angles and mounting frames
• Especially for mounting on all panels such as punched sections, cable channels, frames
• Distributor ring (chrome-plated)• For cascaded cable routing
• to mounting angles and mounting frames
• to all panels
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 74
Accessories
• Slide rail, 740 mm, stationary installation• Matches HP standard dimensions, 740
mm distance between the levels
• 100 kg static load
• Depth-variable slide rail, 1 U• 80 kg static load
• 390-600 / 590-930 mm long
• Particularly slimline design
• Potential equalisation point• Star point for earthing bolt
• Contacts up to 5 earthing straps with 6.3 mm flat-pin connectors
‹Nr.›
MTS May 2006
Innovations 2006
SBU 5 PSM and UPS
(uninterrupted power supply)
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 76
PSM Plus busbar and modules
• Power System Module PSM Plus with four infeeds
• 3-phase / redundant design
• Different module versions, sometimes with double infeed
• Can distribute twice as much power as the latest PSM, i.e. 192 A/busbar
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 77
PSM system
• PSM with 3-phase voltage monitoring• Displays and monitors the connection current and
the active power / phase• For 2000 mm high enclosures with 6 slots• Remote monitoring via CMC-TC
• PSM accessories• Cable lock: connection cable• For all modules with IEC320 C13 jack
• PSM light module• For use as a portable lamp with a NiMH battery• 3 hours illumination time and magnetic
attachment
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 78
Static transfer switch (STS)
Available upon request:
• 482.6 mm (19") design, 2 U
• Switches automatically between two infeeds
• Increases availability through redundancy
• Single-phase switching load: 16 A
• Networking capability (SNMP)
• May be applied in the IT business• Server racks
• Network racks
• Data centres
• Networks in general
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 79
UPS PMC 200, 2nd generation
• UPS modules 10/20 kW• 600 mm wide racks
• UPS modules 30/40 kW• 800 mm wide racks
• Improved efficiency (96%)
• Redundant n+1 system architecture in modules and batteries
• See IT News 2006, p. 20-26
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 80
UPS PMC 200, 2nd generation
• Benefits• Flexible, simple expansion with the
system operational• The fact that modules can be
replaced easily make servicing fast and cost-effective
• May be applied in the IT business• Data centres, IP telephony• Networks in general
• May be applied in the IE business• Mechanical engineering in general• Automotive
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 81
N+1 redundancy in an example with 40 kW
1+1, 40kW modules 2 + 1, 20kW modules 4 + 1, 10kW modules
UPS PMC 200, 2nd generation
‹Nr.›
MTS May 2006
Innovations 2006
SBU 5 Security / monitoring
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 83
CMC-TC
• New CMC-TC software functions• New web design
• Network Time Protocol NTP
• SSL and SSH
• DHCP
• Applications• Large network systems
• RimatriX5 data centre
Customer benefits: More comfort, more security, more transparency
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 84
CMC-TC accessories
• Display Unit II • Graphical, illuminated LED display
• Displays temperature, humidity, access, climate control units, LCP, ActivePSM and PCU
• The network interface of PU II may be set via keys
• Power supply via PU II
• Applications• Applications without network
• Informs locally
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 85
CMC-TC accessories
Redundant power supply for CMC-TC
• Two voltage inputs, one voltage output
• Switches without interruption
• With power pack for 90-230 VAC or 48VDC
• For 24 V DC
• Alarm interface with the I/O unit
• Optical alarm display
7200.210
7200
.210
7320.425
7320.425
24 V DC
AlarmU1 / U2
U1 U2
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 86
CMC-TC accessories
• Voltage monitor with 16 A C19/C20 switched output• Switches high currents 16 A
• In de-energised state: ON
• Switches high-performance IT/server components up to 16 A
• 1 U fixture for CMC-TC sensors• Accommodates up to 22 CMC-TC
sensors
• Cable clamping
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 87
CMC-TC accessories
• Comfort handle for TS8 Legic (WO)• Legic transponder technology
• Receiver aerial in the handle
• Acoustic/optical signal in the handle
• Electronics in the CMC-TC housing• Carrier frequency: 13.56 MHz
• Biometric access system (WO)• Thermal sensor
• Compatible with the CMC access system
• Up to 99 users / 10 fingers for each user
• May be used outdoors
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 88
SSC Rittal KVM technology
• SSC compact 8 • Inexpensive KVM switch based
on standard PC interfaces, 1 U• Compatible with VGA & PS/2• Compatible with other servers
via adaptors• May be combined with SSC
multi (without OSD transfer)
• SSC compact 32 Cat• 32 server ports in 1 U• For SSC: converters for PS/2,
USB & SUN-USB• May be cascaded to up to three
more SSCs; max. 125 servers on one user (with OSD transfer)
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 89
SSC Rittal KVM technology
SSC compact
• Password-protected OSD menu for configuration and server selection
• Selection may also be made via hotkeys
• Convenient function such as autoscan and autoskip
• May be installed in 482.6 mm (19") levels
• Integral wide-range power pack, IEC 320 connection (EN 60320, C14, 100 V-240 V AC 50/60 Hz)
‹Nr.›
MTS May 2006
Innovations 2006
Cooling
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 91
LCP Liquid Cooling Package
• LCP Standard
• Additional dimensions• WxHxD: 300 x 2000 x 1,200 mm
• Connector system replaces the hose clamps
• Solid base tray designed as condensate tray
• Condensate is drained off either via return to to the outside
• Main connection is at the rear or bottom
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 92
LCP Liquid Cooling Package
LCP Extend
• Extends existing room air-conditioning
• Cooling output about 10 kW per rack
• May be retrofitted on rear doors of vented enclosures
• Bayable, door opening max. 90°
• Water connection from below or above
• May be connected to CMC / RiWatchIT
• Compatible with Rittal IT cooling unit line
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 93
LCP Liquid Cooling Package
LCP +
• Same as standard LCP, but with higher output
• Cooling output 30 kW
• WxHxD: 300 x 2000 x 1,200 mm
• Easy servicing for important components(e.g. fans can be replaced without tools)
• Active condensate management
• Cooling even with the server rack doors open
• May be connected to CMC / RiWatchIT
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 94
LCP accessories
• Vertical shielding• May be used HPC server racks
• Prevents "air short circuits"
• Horizontal shielding
• Air inlet/outlet of the cover plate• May be used in the LCP rack
• Top-mounted cover for LCP (200 mm)• May be adapted to 2200 high server racks
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 95
LCP accessories
• LCP ventilation for maintenance works and retrofitting
• Connection hose
• Quick-release couplings for configuring water connections
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 96
IT recooling systems
• Requirements specific to Rimatrix
• Pressure-sealed systems
• Field of application: -20°C to +45°C (outdoor siting)
• May be connected to CMC and collective fault signal
• Increased safety through twin pump and redundant cooling circuits
Thema oder Anlass des Vortrags Autor / Abteilung / Datum 97
4 8 10 12 20 24 30 36 40 48 50 60 70 80 84 90 100 110 120 130 140 150SK 3301.900
SK 3301.901
SK 3301.902
SK 3301.905
SK 3301.910
SK 3301.912
SK 3301.915
SK 3301.920
SK 3301.925
SK 3301.930
Recooling systems Power range of RiMatrix recooling systems in kW
Project business:
Example AWE
Cooling output 4x280 kW
Example
Recooling systems SK 3300.902Cooling output12,000 wattsat Tw = 15°C and Ta = 32°C
IT recooling systems