P14474: Hydrostatic Test Apparatus

Post on 06-Jan-2016

59 views 6 download

description

P14474: Hydrostatic Test Apparatus. Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott. Project Overview. Goals Control pressure, ramp rate, and time Test enclosures against UL1203, UL2225, and CSA 22.2 no. 30 - PowerPoint PPT Presentation

transcript

P14474: Hydrostatic Test Apparatus

Jake ManleyAnushka KalicharanMitchell SedoreBrian BennerKyle Abbott

Project Overview

Goals● Control pressure, ramp rate,

and time● Test enclosures against

UL1203, UL2225, and CSA 22.2 no. 30

● Control test automatically with minimal operator interaction

Constraints:● Must reuse current fixed

displacement pump● 10,000 psi max pressure● Ability to capture results

during test○ Future Labview Integration

Customer Requirements

Top Customer Requirements ● Test Automation complies with

Standards● Ability to Interface with Current Cooper

Product Line● Ability to Acquire Data from Test● Complete Apparatus for On-Site Testing● Control of Pressure, Hold Time, and

Ramp Rate

Engineering Requirements

Engineering Requirements

Top Engineering Requirements● Deliver Maximum Required Pressure to

Enclosure● Withstand Maximum Internal System

Pressure● Deliver Minimum Required Pressure to

Enclosure● Pressure Ramp Rate● Hold Time for 4X Max Internal Explosion

Pressure● Hold Time for 1.5X Max Internal Explosion

Pressure

Functional Decomposition

Functional Decomposition

Functional Decomposition

Functional Decomposition

Concept Selection

Alternatives Considered

● Hold Components: Manifold vs. Inline● Data Transmission: Wired vs. Wireless● Test Control: Hybrid (Digital and

Manual) vs. Strictly Digital.

Manifold vs. Inline Design for Holding

ComponentsManifold

● Pro’s○ Compact, single unit○ Less plumbing

connections■ Less

opportunities for leakage

● Con’s○ Large manifold

■ Difficult to manufacture

○ Less flexibility in component placement

Inline● Pro’s

○ Flexible location of components

○ Small components■ Easy to

manufacture

● Con’s○ More parts and

connections

Ranking of Manifold vs. Inline

Wired vs. WirelessMethod for Data Transmission

Wired● Pro’s

○ Simple○ Reliable○ Inexpensive○ Secure

● Con’s○ Requires Physical

Routing○ Possible Data loss

due to Wire Damage

Wireless● Pro’s

○ Easy to add Components

● Con’s○ Expensive○ Less Secure○ Susceptible to

Interference

Ranking of Wired vs. Wireless

Hybrid vs. Strictly DigitalManner of Test Control

Hybrid● Pro’s

○ Fail-Safe○ Full Automation○ Allows for Manual

Override

● Con’s○ More Components○ More Complexity

Strictly Digital● Pro’s

○ More Compact○ Full Automation

● Con’s○ No Backup System

Ranking of Hybrid vs. Strictly Digital Controller

Selected Concept Overview

System Controller Overview

Risk Analysis

Risk Analysis

Highest Risk

Testing Plan

● Pressure Sensor(s)○ Apply varying pressures to sensor(s) to verify

output matches expected values.○ Calibrate sensor(s) as necessary.

● Structural Integrity of Piping and Hose.○ Perform calculations to determine

approximate pressure for conduit failure.○ Simulate stress experienced by conduit with

finite element model if deemed necessary from calculations.

Testing Plan

● System Controller○ Simulate logic before programming the controller

to debug as necessary.○ Apply stimulus to controller to recreate input from

pressure sensor and observe output waveforms to verify functionality.

● Pressure Control System○ Apply stimuli to pressure controller to simulate

input from test controller to verify functionality and response time.

○ Attach to test controller and apply stimuli to controller.■ This simulates input from pressure sensor and

can be used to verify reaction time and functionality of pressure controller.

Project Timeline

Questions?

BACKUP SLIDES

What is a Hydrostatic Test?

● Tests structural integrity of the product

○ Product: Electrical enclosures

○ Simulates explosion within the electrical enclosure

● �High Pressure Tests :

○ Proof Test

■ Hold time at specified pressure

○ Destructive Test

■ Test to failure

■ Determines safety factor (UL Standards)

Standards

● �UL1203

○ Electrical enclosure: 10 sec hold time without rupture

○ Safety factor of 4x internal explosion pressure

● �UL2225

○ Cable sealing: 10 sec hold time w/o rupture

○ Safety factor of 4x internal explosion pressure

○ Pressure: 100-600psi/min

● CSA22.2 no.30

Current Hydrostatic Test Apparatus

● �Fully functional

● �Manually controlled by technicians

● �Analog pressure and time measurements

● �Isolated Test Environment

● �Follows standards:

○ UL1203

○ �UL2225

○ �CSA22.2 no.30

Project Deliverables

● �Hardware

○ �Complete onsite test apparatus

● �Documentation

○ Maintenance Recommendations

○ �Model for fatigue predictions

○ �User guide for operation

○ �Engineering Drawings

Stakeholders

● �Cooper-Crouse Hinds

○ Joe Manahan

○ �Lab Technicians

○ �Secondary Customers

● RIT

○ MSD Group

○ �Ben Varela

○ �Mike Zona

Customer Requirements

Engineering Requirements

House of Quality

Photos

Photos