Ultra slim bench-top DC Power Supply
R4K-80series
Compact / Light / Versatile
www.matsusada-us .com
NEW
Precise 80W output
Ultra slim bench-top DC Power Supply
R4K-80 Series
HIGH PERFORMANCE
Ultra Slim Sophisticated Bench-top Power Supply
More useful functions are added to existing RK-80 series.
1.38"(35mm)1.38"(35mm)
10.63"(270mm)10.63"(270mm)
4.88"(124mm)
NEW
R4k-80 series is higher performance and next generation model of existing RK-80 series DC variable power supply,
which has been receiving good reputation for its innovative compact size and variable range feature. 4-digit meter and
high resolution D/A, A/D converters are added newly for more precise setting and reading. Needless to say, the
innovative compact size, variable range feature and high operability are remaining same as conventional RK-80. R4K-80
series is the best suitable DC power supply for a variety of applications from laboratory experiment to line productions.
Ultra Slim DCPower Supplies
New user-friendly functions
R4K-80
36V/2.2A
16V/5A
No.1
No.2
No.3
Quick access to the function needed
New and useful functions and stylish front panel design!
Useful new feature of variable setting range
Set voltage/current value within 80W, then turn on output *Not automatic range change which can output 80W all the time. Resetting is required.
Preset setting is automatically displayed when output is off.
OCP is added for more safety operation.
Quick lock with one touch action.Two selectable lock options.
R4K-80 series
02
Useful New 4 Additional FunctionsUseful New 4 Additional FunctionsUseful New 4 Additional Functions
As 1 click of rotary encoder is 1 count, fine setting is possible
Digital interface shall make the data logging and automatic measurement easier.
*Conversion adapters suitable for RS-232C, RS-485 or GPIB is separately required.
With pulse/ramp sequence function(optional) various test pattern can be set without personal computer.
High resolutionD/A, A/D converter integrated
Metel RS-232C Module
OU
T
4-digit meter
Power factor correction and
universal input
Compact and light weight space
saving design
Unique low noise power conversion
technology for research application
For wider output rangeR4K-80L:16V/10AR4K-80:36V/5A
R4K-80M:110V/1.3AR4K-80H:320V/0.5A
4 different models with various
output voltages
80L
80M 80H
80
* When 115VAC Maximum Output
MODELOutput voltage(V)
Output current(A)
Output Power(W)
Ripple
(mVrms) (mArms)Temperature coefficient(ppm/°C)
CV CC
±200
0 to 10 R4K-80L 5 100 to 16
0 to 5 R4K-80 5 50 to 36
0 to 1.3 R4K-80M80
10 20 to 110
0 to 0.5 R4K-80H 20 10 to 320
±10085 to 264VAC47 to 63Hz 1Ø 0.9kg1A 0.5A 99%
*
Input Voltage Input Current (typ) Power factor (typ)Weight(typ)
AC Input
AC in115V
AC in230V
12
3
4
Lineup
Multiple units operation with
master/slave and digital interface
Digital interface as standard function
Various waveform with pulse and rampsequence function at will
03
8
9
Function to memorize 3 different voltage and current settings in addition to standard preset function.No need to adjust the output when different setting, and convenient function for production inspection process or testing which require frequent data taking.
Lock all the function other than reset lock mode, and effective for purpose to avoid mis-operation when controlled.
Function to output ON/OFF of total 32 units from one master unit. (when master/slave)It is possible to delay the ON/OFF time, and simultaneous ON/OFF setting is possible as well.Ideal function for application which require time delay for ON/OFF setting.
Full LOCK Normal LOCK
Lock voltage and current setting dial, and effective for purpose to avoid changing output setting by mistake or when easy emergency stop is required.
3
12
Function to select two different lock functions for two different purpose."Full Lock" locks all the function on front panel, and "Normal Lock" locks all the function except for ON/OFF. "Full Lock" mode shall be good in case mis-operation have to be completely avoided, and
"Normal Lock" mode shall be good in case to avoid mis-operation but secure the way for emergency stop of power supply. You can select the best mode according to your level of "Security", (in both modes, emergency stop is possible with Power Switch.)
LOCK
LOCK LOCK
Press down SETSelect a memorywith 3 buttons
Set voltage andcurrent
OUTPUT ON(From Master)
OUTPUT OFF(From Master)
Up to 32 units
Master
Slave1
Slave2
Slave3
t1 t5
t2 t6
t3 t7
t4 t8
*setting range of t1 to t8 is 0.0s to 99.9s
Memory a
Memory b
Memory c
*
*Master/Slave function is available on the model without -LUs1 option.
Two Mode Lock Function
FUNCTIONS For more convenient operation
Multi Setting Function Delay Trigger Function
04
Remote Functions
Master/Slave Control
GPIB
Dsub
32 units can beconnected to one CO-G32m.
CO-MET2-9
CO-G32m
A
A
A
A
A
Modular jack
Converter
RS-232CRS-485
CO-MET2-25
CO-MET4-25
Enable digital control via GPIB/ RS-232C/ RS-485 as well as one control with Master/Slave function.
A
A
Master
Slave
Up to 32
GPIB enables control of up to 14 CO-G32m modules.
*1) Previous model is Metal RS-232C module.
*2) Previous model is Metal RS-485 module.
CO-M cableOne 2 meter cable is provided per unit. Please notify your sales representative if you need a longer cable or additional cables.
A CO-M cableOne 2 meter cable is provided per unit. Please notify your sales representative if you need a longer cable or additional cables.
*1
*2
Master/Slave control is only possible with units with the same model number.
Master/Slave function is available on the model without -LUs1 option.
The Master/Slave control function allows you to control up to 32 units connected in parallel from a single unit.
Delay trigger function at Master/Slave control can be set for each unit. Furthermore delay trigger function at Master/Slave control can cancel one control functions except for Output by switching Remote/Local, and can set voltage and current preset.
Controlfunction
Write function
Reading function
Output ON/OFF setting
Status output(fault/output/OVP/OCP/OTP/ACF/reversible sense connection)
Maximum 32 units digital control
One control function for multiple units
* Minimum value of each model is same as minimum display of front panel meter.
Output voltage setting /Output current setting
OVP setting /OCP setting
Output voltage reading /Output current reading
Output voltage setting
/Output current setting
OVP setting /OCP setting
Percent mode(100.00%), *voltage current value mode(maximum rated voltage and current value)
Percent mode(100.0%), voltage current value mode(maximum over voltage /over current protection value)
Percent mode(100.00%), *voltage current value mode(maximum rated voltage and current value)
Percent mode(100.00%), *voltage current value mode(maximum rated voltage and current value)
Percent mode(100.0%), voltage current value mode(maximum over voltage /over current protection value)
+S
-S
R
VO IO
Load- +
VL
Compensate the voltage drop (V0-VL) due to resist-ance of output lead or drop of stability by con-tact resistance.(maximum 0.5V)
*+S is common. So external control voltage shall be input with +S as reference. Otherwise it can cause failure.
5V
or VCE
Remote sensing
Remote switch ON/OFF
Sink current 1mA
Output
ON
OFF
Open collector
VCE 0.4V
VCE 2V
Relay
SHORT
OPEN
+S(common)*
Various Digital Control Functions
Digital Interface
05
Functions
Rear panel
12
6
1
2
3
4
5
13
14
9
7
15
16
17
19
18
20
21
22
8
10
11
Front panel
Output voltage and OVP setting display
Output current and OCP setting display
Remote programming displayLight up when output voltage/current control in remote mode.
Output displayLight up when output is on.
OUTPUT ON/OFF switchTo be used to turn output on/off when local mode as well resetting protection functions.
Monitor terminal
Constant voltage operation mode display
Constant current operation mode display
PRESET switch
OVP/OCP switch
LOCK switch
OUTPUT voltage·OVP setting dial
OUTPUT current·OCP setting dial
Power ON/OFF switchThis has priority over all operations for safety reason.
Master/Slave change switch
Digital interface IN For Master/Slave function too
Digital interface OUT For Master/Slave function too
Remote output ON/OFF switch
+Sense
OUTPUT terminal
-Sense
AC inlet
1
2
5
6
7
8
9
10
11
3
4
12
13
14
15
16
17
18
19
20
21
22
06
Specifications
Accessories
Output Control
Output Function
Lock Function
Output Display
Protections
Other Functions
Operation Temp.
Storage Temp.
Storage humidity
Isolation voltage
CV Mode : By rotary encoder on front panel
CC Mode : By rotary encoder on front panel
Wide output range, automatic limit setting at 80W for voltage and current In CV mode output current drop down when output power is more than 84.05W
In CC mode output voltage drop down when output power is more than 84.05W
Lock function locks the output voltage and current setting
Voltage : 4-digit digital meter. *Accuracy is ±0.5% FS ±2 digits
Current : 4-digit digital meter. *Accuracy is ±0.5% FS ±2 digits(*Accuracy of preset setting is ±1% FS ±2 digits)
Over voltage protection (OVP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum voltage Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)
Over current protection (OCP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum current Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)
Over temperature protection. (OTP) : Cut off output at abnormal inside temperature.
Reset(after temperature get down to normal temperature) : Output ON/OFF switch or Remote switch (manual control)
Input brownout(ACF).Blackout protection Output is cut off when input voltage decreased. Reset (when normal voltage value or recovery from blackout) Manual recovery by OUTPUT switch or remote switch for blackout protection(re-output protection function). Automatic recovery when blackout protection is canceled.
Sense reverse connection
Remote switch ON/OFF(TTL or external relay),Remotesensing
Delay trigger: Individual setting of ON delay and OFF delay
(0.0 to 99.9sec)
Multi setting function: Voltage and current memory "a", "b" and "c" setting in addition to standard voltage and
current preset
0°C to 40°C
-40°C to +85°C
20% to 80% (non-condensing)
±250V-DC (Positive or Negative terminal grounding)
·Input AC cable 2.5m single phase 3pin type(1)
·Instruction manual(1)
·Ground plate(1)
Ground plate *For safer operation connect ground plate and output terminal.
07
Dimensions inch(mm)
AC Input Cable
4.88
"(12
4)0.
31"(
8)
OUTPUTOCP
LOCK
SET
OVP/
VCC
A
CV
10.63"(270)0.89"(22.7) 0.16"(4)
1.38"(35)
side
front back
CABLE TYPE 1CABLE TYPE 3
125V / 10A 250V / 10A
CABLE TYPE 4(standard)
250V / 10A
+S
--S
-++
LS-LS+
INPUTAC 100V-240V 47to63Hz
Slave
Master
IN
OUT
Options
*1) When choose -LUs1 option, standard digital interface shall not be added.
*2) See CO series catalog for details and function of digital interface and USB interface.When ordering, suffix the above option number to the model number. <e.g.>R4K-80-LUs1,R4K-80L-LDe,R4K-80M-LDeUs1
When controlling several R4K-80 power supplies via USB, a USB hub will be required between the PC and R4K-80 power supplies.
USB
Enable digital control via USB-LUs1 : USB Interface Board *1 *2
-LDe: Pulse Ramp Sequence
ta, tb, tc and toff can be set with range 1.0s to 99.9h respectively.
tb tc toff
a
b
c
ta
t1
PULSE SEQUENCEUsing the stored voltage and current setting in each memory of a, b and c and multi set function, sequence operation is possible. The setting of repetition to say nothing of a continuous driving can be set. Various different operations, such as repetition of memory a and b or b ,c and off, are possible by setting the set time of memory a, b, c, and/or off to be 0.0. Thus, it makes this model suitable for evaluation test or other applications.
RAMP SEQUENCEThis function controls the ramping up and down the voltage and current to the set value (or from set voltage and current value to 0V/0A). It is convenient to increase( decrease) the voltage and current value slowly.
*The Ramp sequence can be selected from [both set voltage and current], [only set voltage], and [only set current].
COMBINATION OFPULSE and RAMPSEQUENCE
Features of pulse sequence operation and ramp sequence operation can be combined for more convenient operation. In addition, by adding multi set function, sequence operation can be operated using stored voltage and current settings in each memory. The setting of repetition to say nothing of a continuous driving can be set. For example it is possible to slowly ramp up and down the voltage and current to the three different settings, and so, it is useful on various scenes.
Note: The operation accuracy of the timer when sequensing is ±0.5%. Be careful when you use it by the long-term running operation.
t1 and t2 can be set with range 0 to 999s respectively.
t2
0V(Output OFF)
OutputON
OutputOFF
t1
a
c
b
ta t2 tb t3 tc t4 toff0V
(Output OFF)
t1, t2, t3 and t4 can be set with range 0 to 999s respectively.ta, tb, tc and toff can be set with range 0.0s to 99.9h respectively.
Setting Voltage / Current
09
Series Operation · Parallel Operation
Split operation
Vout+-
+-
V1+V2
PS1
V1
PS2
V20V
[caution] Total output voltage is to be up to 250V. Therefore for models with output voltage of over 250V, series operation cannot be conducted. Output current is to be the smallest current of those.
Please keep all the settings of voltage the same. Output current will be the summation of each current.[caution] Please keep OVP level of power supply maximum to prevent any damage.
[caution] In case of +- operation, the remote connector is connected to negative output terminal. So never connect other remote control to the connector.
PS1
PS2
+Vout
-Vout
0V
+-
+-
Series operation
+
-
PS1
PS2
+-
+-
Load
Parallel operation
R4K-80 power supply of same model number can be connected in series or parallel to increase output voltage or current.
♦Book stand
♦Binder
♦Rack mount holder [RMO series]
For one unit operation...
For the applications which require 2 to 6 units combination. Dual, triple and quad multiple operation is possible.
*Cooling fan is needed for more than 3 units combination.
Various accessories are available for convenient use of the unit.
R4K-80 series Accessory Kit
*Power supply is not included in the accessories.
10 Units/1 rack holder, and can be placed in a cabinet. Easy to take one unit out.Best suitable for a system operation.With fan unit.
10
New world standard!
RK-80 series·Variable output range·Low noise switching method·Universal input
Palm top size ULTRA compact DC supply!
R4K-36 series·Palm top size even for 18/2A, 36V/1A output·4-digit meters·Digital interface as standard function
TECHNICAL NOTE
AWG Max current(A)mm2
181614121086
1.11.32.13.35.38.413
27
1118233967
Connection of load
P.S
Parallel connection of load
P.S Di
Connection of load
Ripple
Preset
Io
Vo
100%
0
10%
10% 100%
F.S
F.S
*
When selecting DC power supply
Products on this catalog have been manufactured with consideration of safety as DC power supply, however please follow instruction manual for operation and make sure to ground the ground terminal for your safety.
Products on this catalog have been manufactured on the precondition that they are used in ground electric potential or within the range of the above series operation. Please contact our sales staff when using the product for floating of high electric potential, etc.
Products on this catalog are manufactured with consideration for protection against load discharge. However for specific experiment or continuous discharge such as sputtering, product may need discharge resistance between power supply and load or could not be used at all. Please consult with our sales staff in advance.
We recommend that you contact our sales staff with your requirement before choosing a product so that you can get the best product and the safety as high-voltage equipment is assured.
Important Notice
"F.S × catalog value(*)" is applied for ripple, stability, regulations and temperature coefficient, and "value if F.S × ±0.5%(*)" is applied for high-voltage output linearity, monitor linearity and display linearity, both in the range of 10% to 100% of maximum rating output.
Definition of specifications
Connection · Operation
Applicable scope of specifications
· Please use a short lead wire that is sufficiently thick for the connection.
· Please use PVC electric cable (105°C) that can fully tolerate the voltage used. It is necessary to consider current capacity, length limit of output wire by sensing (0.5V/lead) and so on for wiring with load. Please refer to the following diagram to determine the thickness of cable.
Please insert a diode of which rating is bigger than output voltage and current of power supply to protect the power supply from kick back of load.
Specifications in this catalog, except otherwise specified, refer to values when maximum rating output (full scale*) after 2-hour warm up.
Load
1
Load
2
Load
3
P.S Load
1
Load
2
Load
3
Bad exampleGood example
Inductive load(Transformer or motor)
Indication is in rms that includes high-frequency noise.
Preset value does not show the actual output status accurately. If you need an accurate setting, conduct actual output without load and set a voltage. Also for setting current, conduct output after shorting the output terminal and gradually raise current before setting at a desired value.
11
1137-01A
Customer Inquiry Sheet (R4K-80 series)Please copy this page and fax to above fax number after filling out form below.
USA/canada : 1-888-652-8651other countries : 1-81-75-229-6366FAX
2570 N.First Street Suite 200 San Jose, CA 9513180 Orville Drive Suite 100 Bohemia, NY 117165430 LBJ Freeway, Suite 1200 Dallas, TX 75240 Kyoto-City, Kyoto Japan
Tel: +1-408-273-4573 Fax: +1-408-273-4673Tel: +1-631-244-1407 Fax: +1-631-244-1496Tel: +1-972-663-9336 Fax: +1-972-663-9337Tel: +81-75-229-6355 Fax: +81-75-229-6366
San Jose Office : New York Office :Dal las Of f ice : International Office :
www.matsusada.com/contactwww.matsusada.com/productFor products For contact
Headquarters : 745 Aoji-cho Kusatsu Shiga 525-0041 Japan Tel: +81-77-561-2111 Fax: +81-77-561-2113
<option>
-LDe(Pulse Ramp Sequence) -LUs1(USB I/F)
What product are you interested in?
a quotation
R4K-80 R4K-80M R4K-80HR4K-80L
an explanation of product
introducing one applying for budget
interested in other ( )
a demonstration
Address: State: Zip:
Company name:
Dept.: Title:
Fax:
Name:
Tel:
E-mail:
I would like...
You are currently
Give us your requirement / comment.
Contact information.