PRESSURE SAFET VALVES

(PSV)

&

PRESSURE RELEIF VALVES

(PSRV)

FREQUENCY OF TESTING AND CALIBRATION

PSVs

As every one of us known and its name itself self explanatory, safety valve are very impartment and heart of our plant safety in all aspect.

FREQUENCY OF TESTING AND CALIBRATION

PSVs

As every one of us known and its name itself self explanatory, safety valve are very impartment and heart of our plant safety in all aspect.

FREQUENCY OF TESTING AND CALIBRATION

Testing and Inspection

It is very much essential to keep all safety/ relief valves are in condition to save personnel and plant life.

PSVs

As every one of us known and its name itself self explanatory, safety valve are very impartment and heart of our plant safety in all aspect.

FREQUENCY OF TESTING AND CALIBRATION

Testing and Inspection

It is very much essential to keep all safety/ relief valves are in condition to save personnel and plant life.

For this reason inspection and testing are acting vital role in safety/ relief valves.

FREQUENCY OF TESTING AND CALIBRATION

How to set frequency for testing and calibration?

FREQUENCY OF TESTING AND CALIBRATION

How to set frequency for testing and calibration?To set frequency for testing and inspection we have look into international code for their recommendations.

FREQUENCY OF TESTING AND CALIBRATION

How to set frequency for testing and calibration?To set frequency for testing and inspection we have look into international code for their recommendations.

Which codes are giving guide line for testing and calibration of PSV’s?

FREQUENCY OF TESTING AND CALIBRATION

How to set frequency for testing and calibration?To set frequency for testing and inspection we have look into international code for their recommendations.

Which codes are giving guide line for testing and calibration of PSV’s?

API 576 – Inspection of Pressure reliving Devices

FREQUENCY OF TESTING AND CALIBRATION

How to set frequency for testing and calibration?To set frequency for testing and inspection we have look into international code for their recommendations.

Which codes are giving guide line for testing and calibration of PSV’s?

API 576 – Inspection of Pressure reliving Devices

NBIC – National Board Inspection Code (NB – 23)

RB8400 In-service Inspection of Pressure Relief Devices

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequency

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

This frequency varies widely with the various operating conditions and environments to which relief devices are subjected.

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

This frequency varies widely with the various operating conditions and environments to which relief devices are subjected.

Inspection may usually be less frequent when operation is satisfactory and more frequent when corrosion, fouling and leakage problem occur.

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

This frequency varies widely with the various operating conditions and environments to which relief devices are subjected.

Inspection may usually be less frequent when operation is satisfactory and more frequent when corrosion, fouling and leakage problem occur.

Historical records reflecting periodic test results and service experience for each relief devices are valuable guides for establishing safe and economical inspection frequencies.

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

This frequency varies widely with the various operating conditions and environments to which relief devices are subjected.

Inspection may usually be less frequent when operation is satisfactory and more frequent when corrosion, fouling and leakage problem occur.

Historical records reflecting periodic test results and service experience for each relief devices are valuable guides for establishing safe and economical inspection frequencies.

A definite time interval between inspection or tests should be established for every pressure relieving device on operating equipment. Depending on operating experiences, this interval may vary from one installation to another.

FREQUENCY OF TESTING AND CALIBRATION

What API 576 recommends on frequencyThe inspection of pressure relief devices provides data that can be evaluated to determine a safe and economical frequency of scheduled inspection.

This frequency varies widely with the various operating conditions and environments to which relief devices are subjected.

Inspection may usually be less frequent when operation is satisfactory and more frequent when corrosion, fouling and leakage problem occur.

Historical records reflecting periodic test results and service experience for each relief devices are valuable guides for establishing safe and economical inspection frequencies.

A definite time interval between inspection or tests should be established for every pressure relieving device on operating equipment. Depending on operating experiences, this interval may vary from one installation to another.

Finally no specific frequency from API 576/ API 510

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequency

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

RB 8410 – Recommended Inspection And test Frequencies

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

RB 8410 – Recommended Inspection And test Frequencies

HP Steam

Pressure test to verify nameplate set pressure every three years or as determined by operating experience as verified by testing history.

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

RB 8410 – Recommended Inspection And test Frequencies

HP Steam

Pressure test to verify nameplate set pressure every three years or as determined by operating experience as verified by testing history.

LP Steam

Manual check every 6 months (manual pop up) ; pressure test annually to verify nameplate set pressure or as determined by operating experience as verified by testing history.

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

RB 8410 – Recommended Inspection And test Frequencies

HP Steam

Pressure test to verify nameplate set pressure every three years or as determined by operating experience as verified by testing history.

LP Steam

Manual check every 6 months (manual pop up) ; pressure test annually to verify nameplate set pressure or as determined by operating experience as verified by testing history.

Pressure Vessel and Piping

Frequency of test and inspection of pressure relief devices for pressure vessel and piping service is greatly dependent on the nature of the contents and operating of the system and only general recommendations can be given. Inspection frequency should be based on previous inspection history.

FREQUENCY OF TESTING AND CALIBRATION What NBIC recommends on frequencyTesting may be accomplished by the owner on the unit where the valves is installed or at a qualified test facility. In many cases, testing on the unit may be impractical, especially if the service fluid is hazardous to toxic. Testing on the unit may involve the by passing of operation controls and should only be performed by qualified individuals under carefully controlled conditions. ( in-service test is impractical in many cases)

RB 8410 – Recommended Inspection And test Frequencies

HP Steam

Pressure test to verify nameplate set pressure every three years or as determined by operating experience as verified by testing history.

LP Steam

Manual check every 6 months (manual pop up) ; pressure test annually to verify nameplate set pressure or as determined by operating experience as verified by testing history.

Pressure Vessel and Piping

Frequency of test and inspection of pressure relief devices for pressure vessel and piping service is greatly dependent on the nature of the contents and operating of the system and only general recommendations can be given. Inspection frequency should be based on previous inspection history.

If valves are found to be defective or damaged by system contents during inspection, intervals should be shortened until acceptable inspection results are obtained. Where test records and/or inspection history are not available, the following inspection and frequency are suggested.

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination combination with rupture disks

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

Propane, Refrigerant

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

Propane, Refrigerant Every five years

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

Propane, Refrigerant Every five years

All others

FREQUENCY OF TESTING AND CALIBRATION

What NBIC recommends on frequencyNBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

Propane, Refrigerant Every five years

All others Per Inspection history

FREQUENCY OF TESTING AND CALIBRATION

With the support of this international standards how we can set inspection and testing frequency of our (SAJGAS) PSV’s ?

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

All PRV’s are considered as critical equipment and must undergo a risk assessment to establish a maintenance strategy. In order to minimize complicated scheduling issues a simplified risk assessment procedure has been adopted. The following parameters have been considered:

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

All PRV’s are considered as critical equipment and must undergo a risk assessment to establish a maintenance strategy. In order to minimize complicated scheduling issues a simplified risk assessment procedure has been adopted. The following parameters have been considered:

• Set Pressure

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

All PRV’s are considered as critical equipment and must undergo a risk assessment to establish a maintenance strategy. In order to minimize complicated scheduling issues a simplified risk assessment procedure has been adopted. The following parameters have been considered:

• Set Pressure

• Corrosivity of the process fluid

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

All PRV’s are considered as critical equipment and must undergo a risk assessment to establish a maintenance strategy. In order to minimize complicated scheduling issues a simplified risk assessment procedure has been adopted. The following parameters have been considered:

• Set Pressure

• Corrosivity of the process fluid

• Process Fluid Hazard – toxicity, flammability, explosivity, temperature etc.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive Sweet Gas,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive Sweet Gas, Dry Air, Dry Gas,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive Sweet Gas, Dry Air, Dry Gas, Mixed Refrigerant, Nitrogen,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive Sweet Gas, Dry Air, Dry Gas, Mixed Refrigerant, Nitrogen, Lube Oil

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Probability

The probability of failure shall be a function of the process fluid in which the valve is in service. Each valve is classified as in either clean/non-corrosive service, or dirty/corrosive service. Valves in dirty/corrosive service shall be assigned a probability factor B as per Figure 1. Valves in clean/non-corrosive service shall be assigned a probability factor C. Thermal Relief Valves (TSV’s) shall be assigned a probability of D regardless of service.

Table 1 : PROBABILITY

Corrosivity Process Fluid

Corrosive Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Wet Air, Raw water, Cooling Water, Drinking/Utility Water, Amine, Liquid Sulphur.

Non – Corrosive Sweet Gas, Dry Air, Dry Gas, Mixed Refrigerant, Nitrogen, Lube Oil

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous Wet Air, Dry Air,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous Wet Air, Dry Air, Nitrogen,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous Wet Air, Dry Air, Nitrogen, Drinking Water/ Utility. Raw Water, Cooling Water,

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous Wet Air, Dry Air, Nitrogen, Drinking Water/ Utility. Raw Water, Cooling Water, Lube Oil.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Consequence

The consequence of failure is a function of the process fluid hazard and the set pressure of the valve. Valves classified as being in non-hazardous service, with a set pressure less than 10 bar g shall be assigned a consequence rating III. All valves with a set pressure over 10 bar g regardless of the hazard, or valves in hazardous service regardless of the set pressure shall be assigned a consequence factor II.

Table 2 : CONSEQUENCE

Hazard Classification Process Fluid

Hazardous Steam, Steam Condensate, BFW. Sour Gas, Wet Gas, Amine, Sweet Gas, Dry Gas, Mixed Refrigerants

Non – Hazardous Wet Air, Dry Air, Nitrogen, Drinking Water/ Utility. Raw Water, Cooling Water, Lube Oil.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Risk

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Risk

Risk assessment is a function of the probability versus consequence. The risk assessment matrix adopted for establishing the relative risk for relief valves.

FREQUENCY OF TESTING AND CALIBRATION

RISK ASSESSMENT

Risk

Risk assessment is a function of the probability versus consequence. The risk assessment matrix adopted for establishing the relative risk for relief valves.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADE

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Inspection Grade 3

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Inspection Grade 3The system was under Grade 2 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Inspection Grade 3The system was under Grade 2 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Grade Transfer

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Inspection Grade 3The system was under Grade 2 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Grade Transfer

On the basis of full servicing a Pressure Relief Devices may be progressively transferred to the next higher grade (maximum one grade increase)

FREQUENCY OF TESTING AND CALIBRATION INSPECTION GRADEAn Inspection Grade shall be allocated to each Pressure Relief Device. After completion of the first and each subsequent inspection, the Inspection Grade shall be amended, if necessary, in accordance with the rules specified below. All recommended grade changes must be reviewed by the appropriate Inspection Engineer and approved by the Head of Inspection.

Inspection Grade 0Initially at the commissioning test, all Pressure Safety Devices shall be deemed to be in Grade 0 and shall remain in this grade until the first servicing. This grade should also be applied when the conditions of service are such that:The valve does not meet the requirements for Grade 1 after the first service.

Inspection Grade 1 The valve was under Grade 0 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications, the cleanliness would not have adversely affected its performance and there are no observed defects.

Inspection Grade 2The system was under Grade 1 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Inspection Grade 3The system was under Grade 2 and it opens within an interval of 5% of the cold set pressure, the leakage rate is within the tolerance of the specifications and the internal inspection shows no or minor defects.

Grade Transfer

On the basis of full servicing a Pressure Relief Devices may be progressively transferred to the next higher grade (maximum one grade increase)

FREQUENCY OF TESTING AND CALIBRATION FREQUENCY

FREQUENCY OF TESTING AND CALIBRATION FREQUENCYAn Inspection frequency shall be created for servicing and detail examination of each Pressure Relieving Device listed in separate. Inspection frequencies shall derive as a function of risk and the allocated Inspection Grade. The schedule shall be maintained in future inspection soft wear.

The maximum interval (in months) between servicing of PRV’s shall be as follows:.

FREQUENCY OF TESTING AND CALIBRATION FREQUENCYAn Inspection frequency shall be created for servicing and detail examination of each Pressure Relieving Device listed in separate. Inspection frequencies shall derive as a function of risk and the allocated Inspection Grade. The schedule shall be maintained in future inspection soft wear.

The maximum interval (in months) between servicing of PRV’s shall be as follows:.

FREQUENCY OF TESTING AND CALIBRATION FREQUENCYAn Inspection frequency shall be created for servicing and detail examination of each Pressure Relieving Device listed in separate. Inspection frequencies shall derive as a function of risk and the allocated Inspection Grade. The schedule shall be maintained in future inspection soft wear.

The maximum interval (in months) between servicing of PRV’s shall be as follows:.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:Since this line is Dry Air – Non Hazardous – Consequence from Fig. is II. Even this is non hazardous pressure is more that 145psi.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:Since this line is Dry Air – Non Hazardous – Consequence from Fig. is II. Even this is non hazardous pressure is more that 145psi.

RiskRisk from this Fig. is C – II

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:Since this line is Dry Air – Non Hazardous – Consequence from Fig. is II. Even this is non hazardous pressure is more that 145psi.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:Since this line is Dry Air – Non Hazardous – Consequence from Fig. is II. Even this is non hazardous pressure is more that 145psi.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for C – II and 0 24 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 1.PSV identification : 650 – PSV – 001Location : Instrument Air ReceiverMedia : Dry AirPressure : 152.2 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Dry Air – non corrosive/ clean - Probability from above Fig. is C

Consequence:Since this line is Dry Air – Non Hazardous – Consequence from Fig. is II. Even this is non hazardous pressure is more that 145psi.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for C – II and 0 24 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:Since this line is Steam – Hazardous – Consequence from Fig. is II.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:Since this line is Steam – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is B – II

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:Since this line is Steam – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is B – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:Since this line is Steam – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is B – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for B – II and 0 12 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 2.PSV identification : 500 – PSV – 001Location : DS De-super heaterMedia : LP SteamPressure : 87 PSI (G) SETSize : 6 G 8

Probability: Since this line is Steam – corrosive/ no dirty - Probability from above Fig. is B

Consequence:Since this line is Steam – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is B – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for B – II and 0 12 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

Risk

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is C – II

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for C – II and 0 24 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION SAMPLE FREQUENCY CHECK

For sample check to under stand our frequency methodology, we are going to check three different area PSV’s.

Sample 3.PSV identification : 200 – PSV – 001Location : Amine contactor over head scrubberMedia : Process Gas (Sweet Gas)Pressure : 1319.8 PSI (G) SETSize : 1.5 G 3

Probability: Since this line is Sweet Gas – Non corrosive/ no dirty - Probability from above Fig. is C

Consequence:Since this line is Sweet Gas – Hazardous – Consequence from Fig. is II.

RiskRisk from this Fig. is C – II

Inspection Grade; Since this is initial stage, inspection grade as 0

FrequencyFrequency from Table – 3 for C – II and 0 24 months.Once first service we should change the inspection grade accordingly.

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBIC

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBICSample 1

Dry Air – 24 months

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBICSample 1

Dry Air – 24 months

Sample 2

LP Steam – 12 months

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBICSample 1

Dry Air – 24 months

Sample 2

LP Steam – 12 months

Sample 3

Sweet gas – 24 months

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBICSample 1

Dry Air – 24 months

Sample 2

LP Steam – 12 months

Sample 3

Sweet gas – 24 months

NBIC suggested frequency for Pressure vessel and Piping

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBICSample 1

Dry Air – 24 months

Sample 2

LP Steam – 12 months

Sample 3

Sweet gas – 24 months

NBIC suggested frequency for Pressure vessel and Piping

Service Inspection Frequency

Steam Annual

Air& Clean Dry Gasses Every three years

Pressure relief valves in combination Every five years combination with rupture disks

Propane, Refrigerant Every five years

All others Per Inspection history

FREQUENCY OF TESTING AND CALIBRATION

Comparison of Frequency Obtained to NBIC

For the first time of service all PSV’s will set for minimized level of frequency, after the first service this frequency will be revised based on Inspection Grade obtained.

FREQUENCY OF TESTING AND CALIBRATION

Which Area in our plant (SAJGAS) is critical now?

As we discussed we can derive best frequency for our plant PSV’s.

Since our plant is under preservation, PSV’s testing and calibration not required at present, Because we have to test again before commissioning.

Commissioning tests of Pressure Relief Valves on new units should be carried out not more than 6 months prior to start up of the new units.

We have to look in to active PSV’s in our plant at present like instrument Air, Nitrogen package.

If it is required we will proceed for this area PSV’s testing and calibrations.

Thank you