Post on 03-Apr-2018
transcript
7/28/2019 Star Fire Shutter.pdf
1/4
Fire Resistant Roller Shutterire Resistant Roller ShutterMotorized Roller Shutterotorized Roller Shutter
TMMby Star Rollingy Star RollingNon-Insulated (1, 2 & 4 Hour)on-Insulated (1, 2 & 4 Hour)
Overall
RollerShutter
Width Cas
ing
Heigh
t(H)
RollerShutterOpeningHeight
OverallRollerShutter
Height
CasingDepth(D)
Motor Area 1
MotorArea2
All copyrights in this printing material are reserved
GalvanizedCurvedInterlo
ckingSlats
MS Angle Rei
nforcedSide
Guide
MS AnglesReinforc
edBo
ttomBar
Fire Resistant Roller Shutterire Resistan t Roller Sh utterMotorized Roller ShutterTMby Star Rolling
Star Rollings Fire Resistant Roller Shutter(Non-insulated) powered by motor operator was tested
by SIRIM (Malaysia) Berhad and advised by BRANZ
(Building Research Association of New Zealand) and
successfully benchmarked against the British Standard
BS476:Part22:1987 which is equivalent to the Malaysian
Standard (MS1073:Part3:1996) that is approved by
BOMBA Malaysia.
Star Rollings Fire Resistant Roller Shutter is the
excellent choice for building compartmentalization tofulfill the requirement of fire fighting design.
PROUDLY
MALAYSIAN
BOMBA
APPROVED
SIRIM
TESTED
BSBRITISH STANDARD
British Standard
BS 476 Part 22 1987COMPLIED
Malaysia Standard
MS 1073 Part 3 1996
EQUIVALENT
BRANZ
ADVISED
7/28/2019 Star Fire Shutter.pdf
2/4
Clearance Guide Line
Construction of Mounting Wall
The general requirement for the mounting
wall must comply with the relevant fire
fighting standards in order to comply with the
relevant fire fighting compartmentalization
requirements. Mounting points of the roller
shutter are recommended to be
stiffener-reinforced concrete.
Free of Obstruction
It is imperative for the mounting points and
surroundings to be free of obstruction, such as
piping, wiring, ducting, and other possible
building construction.
Oversized Roller Shutter Delivery
Oversized roller shutters are recommended to
be scheduled for delivery to construction site
prior to erection of space restricting interior
partition and wall.
Clearance Specifications & Details
Standard Installation Position
OpeningWidth
Opening
Height
A
B B
Ceiling
Clearance for Standard Fire Resistant Roller ShutterSide Guide (All Dimensions in mm)Opening
Height
480 above
520 above
250 above
250 above
Up to 3000
Up to 6000
Clearance for
Headroom (A)
Clearance for
Side Guide (B)
Roller shutter
Opening Width
Wall Opening
Width
All copyrights in this printing material are reserved
Fire Resistant Roller Shutterire Resistant Roller ShutterMotorized Roller Shutterotorized Roller ShutterTMMby Star Rollingy Star RollingNon-Insulated (1, 2 & 4 Hour)on-Insulated (1, 2 & 4 Hour)
7/28/2019 Star Fire Shutter.pdf
3/4
Fire Resistant Roller Shutterire Resistant Roller ShutterMotorized Roller Shutterotorized Roller ShutterTMMby Star Rollingy Star RollingNon-Insulated (1, 2 & 4 Hour)on-Insulated (1, 2 & 4 Hour)
All copyrights in this printing material are reserved
Product Standards & Certification
Test Duration: 0hr01min
Manufacturing License by
BOMBA (Putrajaya)
Manufacturing Process Audited by
SIRIM (Malaysia)Berhad
Exceeded
240 minutes
BS 476 Part 22 1987
Test Duration: 1hr20min
Test Duration: 2hr40min After Test
7/28/2019 Star Fire Shutter.pdf
4/4
Motor OperatorDepending on the roller shutter specification, Star
Rolling will recommend a suitable capacity of roller
shutter motor (220v: 60Hz: 1Phase or 415v: 60Hz:
3Phase, Insulation Class E). All motor operators
recommended shall have:
- Manual override chain
- Auto-heat-cutoff thermo system
- Button switch encased in protected key box
- Mechanical gravity closing device
- Closure or opening trigger relay
To provide DC24V Relay connected to the
building fire-fighting system to trigger the
closure or opening of the shutter in the event of
fire. (The connection and commisioning of the
system shall be done by the fire-fighting
specialist).
- The applicable power supply must be provided
and located near the roller shutter motor
postion.
Optional Accessories
- Heat-sensitive Mechanical Closure DeviceHeat-sensitive mechanical device to trigger the
closure of the shutter when the surrounding
temperature reaches between 60c-70c. This
device is reusable.
Side Guide Mounting & Details
Operator & Optional Accessories
All copyrights in this printing material are reserved
STAR ROLLING SHUTTER SDN. BHD.
Tel: 03-61890332 Fax: 03-61898329
80 Jalan 2/10B, Spring Crest Industrial Park
68100 Batu Caves, Selangor, Malaysia
Roller shutter is our specialization
TM
Fire Resistant Roller Shutterire Resistant Roller ShutterMotorized Roller Shutterotorized Roller ShutterTMMby Star Rollingy Star RollingNon-Insulated (1, 2 & 4 Hour)on-Insulated (1, 2 & 4 Hour)
Roller shutter slats
90 mm
51 mm
90 mm
80 mm
50 mm
Standard Wall Mounting(Recommended)
Roller Shutter Slats
90 mm
51 mm
90mm
Side Wall Mounting
Copyright Note:
All logos (BOMBA, SIRIM, MS (Malaysian Standard) and
BRANZ (Building Research Association of New Zealand)
are the intellectual properties of the respective
organizations.
Star Rollings
Motor Operator
Note: This picture is to
illustrate the general
working mechanism of
Star Rollings motor
operator. Actual
installation and
assembly could vary
from illustration.