SR
LV
UE
EX
UHVE
OHE
OHT
*** DISTANCE TO HIGHEST OPERABLE PART OF EQUIPMENT
CIRCUIT BREAKER PANEL
MOMENTARY CONTACT SWITCH
PUSH BUTTON
SINGLE RECEPT.
FAN SPEED CONTROLTIME DELAY SWITCH
SWITCHED DUPLEX RECEPT.
FOURPLEX RECEPT.
DUPLEX RECEPT.
ABOVE COUNTER RECEPT.
DEDICATED DUPLEX RECEPT.
240 VOLT RECEPT.
EQUIPMENT PLUG
RECEPT ON DROP CORD (DUPLEX SHOWN)RECEPT ON CORD REEL (DUPLEX SHOWN)
FLUSH FLOOR RECEPT. (DUPLEX SHOWN)
ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED.DEVICES INDICATED AT 48" MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 48".DEVICES MAY BE INSTALLED IN CONCRETE MASONRY UNITS WITH THE TOP OF THE DEVICE AT 48".
* DISTANCE ABOVE TOP OF DOOR FRAME
J
TIMER SWITCH
WALL HEATER (TYPE DENOTED)
** DISTANCE TO TOP OF EQUIPMENT OR DEVICE
D1
H2
HATCHED SYMBOL INDICATES REMOVED
HAND OR HAIR DRYER (TYPE DENOTED)
DASHED SYMBOL INDICATES EXISTING
H
T
TC
IROS
R
SF-1
T
BUS DUCT WITH PLUG UN DISCONNECT (FUSED)
LIGHT LEVEL SENSOR - TYPE DENOTED
TIME CONTROL SWITCH (TIME SWITCH)
HUMIDISTAT
THERMOSTAT
PHOTOCELL
ENCLOSED CIRCUIT BREAKER
RELAY
COMB. MOTOR STARTER (NON-FUSED)
MAG. MOTOR STARTER OR CONTACTOR
SAFETY DISC. SW. (FUSED)
SAFETY DISC. SW. (NON-FUSED)
COMB. MOTOR STARTER (FUSED)
POWER OR DISTRIBUTION PANEL
MOTOR (SEE SCHEDULE)
TRANSFORMER (TYPE DENOTED)
MOTOR HP. RATED SWITCH
SPECIAL CABINET (TYPE DENOTED)
J
J J
A
P
A
GROUND CONNECTION - EXOTHERMIC WELD
GROUND CONNECTION TO STEEL OR STRUCTURE
SPECIAL CONNECTION (SEE SCHEDULE)
SPECIAL RECEPT. OR CONN. (SEE SCHEDULE)
JUNCTION BOXPULL BOX
GROUND ROD (PLAN VIEW)
SURGERY SERVICE COLUMN
CLOCK (TYPE DENOTED)
POWER POLE (OPEN OFFICE STYLE)
MULTIOUTLET ASSEMBLY (TYPE DENOTED)
MULTIOUTLET ASSEMBLY (TYPE DENOTED)
POWER SYMBOLS
FLEXIBLE CONDUIT OR FIXTURE WHIP
PROJECTOR CONTROL OUTLET
CCTV CAMERA WITH PAN/TILT DRIVE
**** DISTANCE BELOW CEILING
CCTV CAMERA
***** DISTANCE TO BOTTOM OF DEVICE
SPEAKER (WALL OR CEILING MT.)S
MICROPHONE OUTLET
HORN TYPE SPEAKER
VOLUME CONTROLV
UNDERFLOOR RACEWAY SYSTEM
CABLE TRAY
INFORMATION OUTLET
WALL TELEPHONE OUTLET
INTERCOM OUTLET LOCATION
TELEPHONE OUTLET
TELEVISION OUTLET
W
DOOR CONTACTS
CARD READER
ELECTRIC STRIKE
MOTION DETECTOR (TYPE DENOTED)MD
ES
KEYPAD
F.A. PULLSTATION (TYPE DENOTED)
F.A. DOOR CLOSER
F.A. DOOR HOLDER
F.A. INDIVIDUAL ADDRESSABLE MODULE
FIRE ALARM SHUT DOWN RELAY
F.A. ZONE ADDRESSABLE MODULE
FR
FP
HEAT DETECTOR (TYPE & TEMP DENOTED)
CONDUIT TRANSITION DOWN
CONDUIT TRANSITION UP
BRANCH CIRCUIT HOME RUN
UNDERGROUND HIGH VOLTAGE ELECTRICAL
UNDERGROUND ELECTRICAL
LOW VOLTAGE POWER WIRING
EXISTING CONDUIT
OVERHEAD TELEPHONE
OVERHEAD ELECTRIC
CONDUIT EXPOSED
SURFACE RACEWAY
CONDUIT STUBBED OUT
CONDUIT CONCEALED BELOW FLOOR
CONDUIT CONCEALED IN WALL OR OVERHEAD
FIRE ALARM CHIME
FIRE ALARM BELL
FIRE ALARM BELL W/STROBE (CANDELAS)
SMOKE DETECTOR (TYPE DENOTED)
FIRE ALARM STROBE (CANDELAS)
FIRE ALARM SPEAKER W/STROBE (CANDELAS)
FIRE ALARM CHIME W/STROBE (CANDELAS)
P
FIRE ALARM HORN
FIRE ALARM HORN W/STROBE (CANDELAS)
F
110cd
UTILITY SERVICE POWER POLE (SITE)
UNDERGROUND TELEPHONEUT
UCOM UNDERGROUND COMMUNICATIONSUTV UNDERGROUND CABLE TELEVISION
UFIBR UNDERGROUND FIBER OPTIC
DEDICATED FOURPLEX RECEPT.
MC
T
TD
SP
M
B
P
PB
VARIABLE FREQUENCY DRIVE
ALS
CP
OCCUPANCY SENSOR - TYPE DENOTED
IC
S
S S
M
P
110cd
110cd
110cd
F
F
F
F
F
F
110cd
P
FIRE ALARM REMOTE ANNUNCIATORFA ANNUN
Z
I
DC
CR
MAGNETIC LOCKML
IR
F S
CONDUIT SLEEVE
1 KEYED NOTE (SEE SCHEDULE)
WIRELESS ACCESS POINTWAPGFI RECEPT.
ABOVE COUNTER GFI RECEPT.
TV
FLUSH CEILING MOUNT RECEPT.
SYMBOLS & ABBREVIATIONS
CIRCUITRY SYMBOLS
SIGNALS & COMMUNICATION SYMBOLS
MISCELLANEOUS SYMBOLS
FLAG NOTE
CENTERLINE
LIGHT FIXTURE ON (EM) LIFE SAFETY BRANCH
LIGHT FIXTURE WITH EMERGENCY BALLAST
LIGHT FIXTURE ON EMERGENCY CIRCUITLIGHT FIXTURE ON (EM) CRITICAL BRANCH
2 POLE SINGLE THROW SW.
SINGLE POLE SW.
DIMMER SWITCH
OCCUPANCY SENSOR SWITCH
2
3
KEYED SW.
3-WAY SW.
4-WAY SW.
LIGHTING SYMBOLS
WALL MOUNTED FLOODLIGHT
POLE MOUNTED LIGHT
RECESSED LIGHT
SURFACE LIGHT
EXIT SIGN
SUSPENDED OR PENDANT LIGHT
TRACK AND TRACK LIGHT
SURFACE LINEAR LIGHT
STRIP LIGHT
EMERGENCY BATTERY LIGHT
RECESSED LINEAR LIGHT
POLE MOUNTED FLOODLIGHT
P2P1
TR1T1T1
EM
H
ST1
BB
G
AA
R
C D
F
4
K
D
OS
MULTIPLE SERVICE OUTLETOUTLET IN FLOOR (MICROPHONE SHOWN)M
MULTIPLE SERVICE FLR OUTLET
ELEVATION MARKER
xx.xx
X - INDICATES DETAIL NUMBERX.XX - INDICATES SHEET WHERE DETAIL IS FOUND- DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL
XX-X EQUIPMENT IDENTIFIER
KEYNOTE
KEY NOTES:1
NOTE:"CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE INTHE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEENCOORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BYTHE GENERAL CONTRACTOR. "NEEDED", "PROVIIDE", AND "INSTALL" MEANS ALL ITEMS CALLEDOUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUTREQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM.
SCOPE:THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONALELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR,MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK.
PERMITS AND FEES:THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES ANDINSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TOSTARTING THE WORK.
WARRANTY:THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREEOF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATEOF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR ORREPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHEREXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS ANDWORKMANSHIP.
CODES:PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE,STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATEOR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDINGOWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS,CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENTSTANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY.
STANDARDS:EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC,ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACHINDIVIDUAL UNIT OR ASSEMBLY.
COPYRIGHT 2016
GENERAL NOTES:
THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECTCONTAINED HEREIN. SEA-TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THEFOLLOWING STIPULATIONS:
1. THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS ANINSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA-TAC ELECTRIC, INC.AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THEWRITTEN CONSENT OF SEA-TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN AREPROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS.
2. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS ASTEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BEDISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCHDISCREPANCIES EXIST, ONLY THE PHYSIAL DOCUMENTS AND DRAWINGS CAN BE RELIED ONTO REFLECT THE WORK OF SEA-TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES ORWARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN.
3. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCUARCY,UTILITY, OR SUITABILITY FOR ANY PRUPOSE FOR ANY DATA THESE DRAWINGS CONTAIN.
COPYRIGHT 2016
NOTES REGARDING DRAWINGS:GENERAL DESCRIPTION SCOPE OF WORKELECTRICAL CONSTRUCTION FOR CORE & SHELL OF NEW ONE STORY METAL STUD BUILDING TO INCLUDE THE FOLLOWING:• (1) 2000A 480V ELECTRICAL SERVICE, FEEDERS & PANELBOARD• (1) POWER CHASE TO EACH PROPOSED TENANT SPACE• (1) 2” LV CHASE TO EACH PROPOSED TENANT SPACE• (1) 4X8 TELE/DATA BACKBOARD• (1) 1” CHASE TO EACH PROPOSED TENANT SPACE FOR FIRE ALARM• (8) EMERGENCY EGRESS LIGHTS• (1) DEDICATED RECEPTACLE IN ELECTRICAL ROOM• (1) DEDICATED RECEPTACLE ON PHONE BOARD• (10) WP GCFI RECEPTACLES ON ROOF FOR HOLIDAY LIGHTING• (1) PROGRAMMABLE LIGHTING CONTROL PANEL• (3) WP GFCI RECEPTACLES AT BUILDING EXTERIOR• PROVIDE AND INSTALL (11) 4’ F-1 FIXTURES• PROVIDE AND INSTALL (8) F-2 FIXTURES• PROVIDE AND INSTALL (25) F-3 FIXTURES• PROVIDE AND INSTALL (6) F-4 FIXTURES
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
3 P
M
12" = 1'-0"
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E0.01
SYMBOLS AND ABBREVIATIONS
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
ABBREVIATIONS
A, AMP AMPERE
AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR+6" ABOVE COUNTERS WITHOUT BACKSPLASH.
AFF ABOVE FINISHED FLOOR
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAGE
BTS BASE TRANSFER STATION
CB CIRCUIT BREAKER
CKT CIRCUIT
DED DEDICATED
DW DISHWASHER
E EXISTING
EPO EMERGENCY POWER OFF
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FBIOC FURNISHED BY OTHERS INSTALLED BY CONTRACTOR
FI FILM ILLUMINATOR
G, GND GROUND
GD GARBAGE DISPOSAL
GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER
HT HEIGHT
HWT HOT WATER TANK
IGN IGNITION
J-BOX JUNCTION BOX
MW MICROWAVE - COORDINATE MOUNTING HEIGHT
N NEUTRAL
NC NURSE CALL
P POLE
PH PHASE
PNL PANEL
PROVIDE FURNISH AND INSTALL
R RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE-INSTALLED ASSHOWN)
REC RECEPTACLE
REFER REFRIGERATOR
RO RACEWAY ONLY
S SAFETY TYPE
TELCO TELEPHONE COMPANY
TELE TELEPHONE
TR TELEPHONE RISER
TYP TYPICAL
UC UNDERCABINET
V VOLT
W WIRE OR WATT
W/O WITHOUT
WP WEATHERPROOF
DRAWING INDEX
E0.01 SYMBOLS AND ABBREVIATIONS
E0.02 ELECTRICAL SCHEDULES
E1.01 ELECTRICAL SITE PLAN
E2.01 LEVEL 1 POWER PLAN
E2.02 MEZZANINE, ENLARGED ELECTRICALROOM, AND ENLARGED LOADING DOCKPOWER PLAN
E2.03 MAIN ROOF POWER PLAN
E5.01 ONE-LINE RISER DIAGRAM
No. Description Date
1 CITY OF KIRKLANDREVIEW COMMENTS
11/02/2016
1
11-8-2016
ENR16-08749Page 1 of 7
City of KirklandReviewed by J Tumelson11/22/2016
MUST REMAIN ON JOBSITE
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
3 P
M
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E0.02
ELECTRICAL SCHEDULES
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
Checker
Author
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
5 WHERE FIXTURES ARE SHOWN SHADED PROVIDE BATTERY BALLAST WITH REMOTE TEST BUTTON.
4. CONTRACTOR TO VERIFY CEILING CONDITIONS FOR PROPER MOUNTING HARDWARE
3. ALL FLUORESCENT AND HID LIGHTING FIXTURES SHALL BE PROVIDED WITH IN-LINE GLR FUSE.
2. PROVIDE COLD WEATHER BALLASTS FOR ALL OUTDOOR FIXTURES.
CLOSING FOR ENGINEERING ANALYSIS
TO BE DETERMINED BY ENGINEER. ALL SUBSTITUTIONS SHALL INCLUDE PHOTOMETRICS AND BE RECEIVED (5) BUSINESS DAYS PRIOR TO
PHOTOMETRICS, CONSTRUCTION/COMPONENT QUALITY AND DESIGN INTEGRITY ARE SHOWN TO BE EQUAL TO THE DESIGN INTENT. FINAL DISCRETION
ALL SUCH ITEMS DISCLOSED IN FIXTURE DESCRIPTION AND/OR SPECIFICATIONS. SUBSTITUTION OF FIXTURE TYPES WILL ONLY BE ACCEPTED IF
ALL OPTIONS, ACCESSORIES AND/OR FIXTURE COMPONENTS MAY NOT BE REFLECTED IN THIS NUMBER AND CONTRACTOR RESPONSIBLE FOR PROVIDING
1. ALL INDICATED CATALOG NUMBERS REPRESENT A DESIGN BASIS ONLY AND CORRESPOND TO THE LISTED MANUFACTURERS SERIES NUMBER.
GENERAL NOTES
OR APPROVED EQUAL OR APPROVED EQUAL LED LED
S-2 TO BE DETERMINED TO BE DETERMINED 277 1 42W 42W MAN-DOOR EGRESS LIGHT FIXTURE.
OR APPROVED EQUAL OR APPROVED EQUAL LED LED
S-1 TO BE DETERMINED TO BE DETERMINED 277 1 42W 42W EGRESS LIGHT FIXTURE.
OR APPROVED EQUAL OR APPROVED EQUAL UL LISTED FOR WET LOCATIONS.
DF-2 TO BE DETERMINED TO BE DETERMINED DECORATIVE EXTERIOR SCONCE. MAXIMUM ALLOWANCE OF $2500 FOR FIXTURES.
OR APPROVED EQUAL OR APPROVED EQUAL $2500 FOR FIXTURES. UL LISTED FOR WET LOCATIONS.
DF-1 TO BE DETERMINED TO BE DETERMINED 3'-0" DECORATIVE EXTERIOR PENDANT AT BUILDING "A" - WHOLE FOODS. MAXIMUM ALLOWANCE OF
OR APPROVED EQUAL OR APPROVED EQUAL DRIVER
F-4 SPECTRUM LIGHTING SGE6LEDGV-26W-30K-E2-(COORDINATE)-AR6222GV-SO-277 277 1 26 LED 28.6 RECESSED LED DOWNLIGHT AT EXTERIOR CANOPY LOCATIONS. UL LISTED FOR WET LOCATION.
OR APPROVED EQUAL OR APPROVED EQUAL LED DRIVER 12V TRANSFORMER REQUIRED FOR OPERATION. UL LISTED FOR WET LOCATION.
F-3 LIMIERE 203-CRS-50MR16-12-(VERIFY)-LVR (HEX CELL LOUVER) 12 1 10W LED 50 ELECTRICAL CONTRACTOR TO PROVIDE 10W SORAA OUTDOOR LED MR16 41 DEGREE, 2700K.
CAMBRIA SERIES BUILDING MOUNTED ADJUSTABLE DOWLIGHT CONCEALED BEHIND CANOPY.
OR APPROVED EQUAL OR APPROVED EQUAL LED DRIVER TO COORDINATE ALL PARTS AND ACCESSORIES FOR A FULLY OPERABLE LIGHTING SYSTEM.
F-1 LUMINII KENDO M WET-2900K-MO-S-F-F-SA 277 1 3.2W/LF LED 3.2W/LF LED UPLIGHT AT BUILDING CANOPY. UL LISTED FOR WET LOCATION. ELECTRICAL CONTRACTOR
SITE LIGHTING
OR APPROVED EQUAL OR APPROVED EQUAL DRIVER LIFE. INTEGRAL 2-CIRCUIT TRANSFER RELAY & NICAD BATTERY FOR EMERGENCY OPERATION.
X-01 LITHONIA EXGLEDELMD 277 1 5W LED LED 5 SHOWN ON PLANS. WHITE POLYCARBONATE HOUSING WITH STENCIL FACE. 20-YEAR LED
UNIVERSAL MOUNT LED EXIT SIGN WITH GREEN LETTERS, FACES AND ARROW INDICATORS AS
OR APPROVED EQUAL OR APPROVED EQUAL
DN
J
J
J
J
-
-
--
15'-0"
2000KVA PSEUTILITY XFMRBLDG A & B
(6) 4" PVC-40(4) 750 KCMIL AL (EA)
DF-1 DF-1 DF-1 DF-1 DF-1 DF-1 DF-1 F-4 F-4 F-4 F-4 F-4 F-4 F-4 F-4 F-4 F-4 F-4
F-4
F-4
DF-2
DF-2
DF-2
DF-2
DF-2
DF-2
F-1-180'-0"
MDS-A
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
1
1
B
C
D
E
F
G
A.4
A.5
E.8
E.2
D.7
C.8
B.9
B.1
A.8
1234567
2.73.4
4.85.4
5.8
5.9
1.21.73.54.56.8 6.6 5.7 5.3 2.5
A.2
A.1
A.3
A1.9
F.1
F.7
8.1
8.2
Y
S-1
S-1
S-1
S-2
S-2
S-2
S-2
S-2
EM
EMEM
EM
EM
11
-
---
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
4 P
M
3/32" = 1'-0"
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E1.01
ELECTRICAL SITE PLAN
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
GENERAL NOTES
1. MULTI-WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4REQUIREMENTS.
2. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALLBE AS SELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITHARCHITECT PRIOR TO ORDERING
3. EQUIPMENT SHOWN IN BOLD IS NEW.
4. EQUIPMENT SHOWN IN DASHED IS EXISTING.
3/32" = 1'-0"
SITE ENLARGED ELECTRICAL PLAN
KEY NOTES
1 ELECTRICAL CONTRACTOR TO TERMINATE LIGHTING WIRINGAT JUNCTION BOX. EXTERIOR LIGHTING TO BE CIRCUITEDUNDER TENANT IMPROVEMENT PHASE.
No. Description Date
11-8-2016
ENR16-08749Page 3 of 7
City of KirklandReviewed by J Tumelson11/22/2016
--
PANEL MDS-A
B
C
D
E
F
G
A.4
A.5
E.8
E.2
D.7
C.8
B.9
B.1
A.8
1234567
2.73.4
4.85.4
5.8
5.9
1.21.73.54.56.8 6.6 5.7 5.3 2.5
A.2
A.1
A.3
A1.9
F.1
F.7
8.1
8.2
Y
E2.02
2
WP
WP
WP
WP
E2.02
3
1
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
4 P
M
3/32" = 1'-0"
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E2.01
LEVEL 1 POWER PLAN
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
GENERAL NOTES
1. MULTI-WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS.
2. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE ASSELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITH ARCHITECT PRIORTO ORDERING.
3. EQUIPMENT SHOWN BOLD IS NEW.
4. EQUIPMENT SHOWN DASHED IS EXISTING.
5. ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALLDRAWINGS.
6. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS.
7. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUTPRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER.
8. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY.COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS ANDCASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OFDEVICES PRIOR TO ROUGH IN.
9. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE ULLISTED.
3/32" = 1'-0"
LEVEL 1 POWER PLAN
No. Description Date
1 CITY OF KIRKLANDREVIEW COMMENTS
11/02/2016
11-8-2016
ENR16-08749Page 4 of 7
City of KirklandReviewed by J Tumelson11/22/2016
ELEVATOR
104
BC3456
2.7
3.4
4.85.4
5.8
5.9
A.2
A.1
A.3
A1.9
8.1 8.2
6
A.2
A.1
A1.9
8.1
1
4 3.4
A.2A1.9
MDS-A
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
5 P
M
As indicated
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E2.02
MEZZANINE, ENLARGEDELECTRICAL ROOM, AND
ENLARGED LOADING DOCK POWERPLAN
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
GENERAL NOTES
1. MULTI-WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS.
2. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE ASSELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITH ARCHITECT PRIORTO ORDERING.
3. EQUIPMENT SHOWN BOLD IS NEW.
4. EQUIPMENT SHOWN DASHED IS EXISTING.
5. ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALLDRAWINGS.
6. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS.
7. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUTPRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER.
8. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY.COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS ANDCASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OFDEVICES PRIOR TO ROUGH IN.
9. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE ULLISTED.
3/16" = 1'-0"
MEZZANINE POWER PLAN
1/4" = 1'-0"2
LEVEL 1 ENLARGED LOADING
DOCK POWER PLAN
KEY NOTES
1 ELECTRICAL CONTRACTOR TO PROVIDE RACEWAY FOR FUTURELOADING DOCK MOTOR, ROLL-UP DOORS, AND CONTROL BOX.ELECTRICAL CONNECTIONS TO BE PROVIDED BY TENANT.
No. Description Date
1 CITY OF KIRKLANDREVIEW COMMENTS
11/02/2016
1/4" = 1'-0"3
LEVEL 1 ENLARGED
ELECTRICAL ROOM1
11-8-2016
ENR16-08749Page 5 of 7
City of KirklandReviewed by J Tumelson11/22/2016
J
--
B
C
D
E
F
G
A.4
A.5
E.8
E.2
D.7
C.8
B.9
B.1
A.8
1234567
2.73.4
4.85.4
5.8
5.9
1.21.73.54.56.8 6.6 5.7 5.3 2.5
A.2
A.1
A.3
A1.9
F.1
F.7
8.1
8.2
Y
1
WP
WP
WPWP WP
WP
WP
WP
WP
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
5 P
M
3/32" = 1'-0"
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E2.03
MAIN ROOF POWER PLAN
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
GENERAL NOTES
1. MULTI-WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS.
2. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE ASSELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITH ARCHITECT PRIORTO ORDERING.
3. EQUIPMENT SHOWN BOLD IS NEW.
4. EQUIPMENT SHOWN DASHED IS EXISTING.
5. ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALLDRAWINGS.
6. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS.
7. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUTPRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER.
8. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY.COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS ANDCASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OFDEVICES PRIOR TO ROUGH IN.
9. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE ULLISTED.
3/32" = 1'-0"
MAIN ROOF POWER PLAN
KEY NOTES
1 ELECTRICAL CONTRACTOR TO TERMINATE RECEPTACLE WIRING ATJUNCTION BOX. EXTERIOR ROOFTOP POWER TO BE CIRCUITED UNDERTENANT IMPROVEMENT PHASE.
No. Description Date
11-8-2016
ENR16-08749Page 6 of 7
City of KirklandReviewed by J Tumelson11/22/2016
250kCMIL CU
G
N
PROVIDE UFER GROUND: 20' BARECOPPER CABLE IN CONCRETEFOOTING SIZED AND INSTALLEDPER NEC 250-81(c) BOND TO MAINWATER PIPE.EXOTHERMIC WELD OR
OTHER APPROVED METHOD
MAIN WATER PIPE
M
2000
A/3
P
MAIN DISTRIBUTION SWITCHBOARD2000A, 480Y/277V 3PH, 4WW/KIRK KEY SYSTEM42,000 AIC
XFMR VAULT
NEW SERVICE FEEDERS:
(6) 4" PVC-40
(4) 750 KCMIL AL (EA)
*PROVIDE AND INSTALL NEW, 2000A SERVICE
FEEDERS (UP TO 75'-0" WITHIN 5'-0" OF
BUILDING) FOR NEW 2000A, 480Y/277V,3P,4W
MAIN DISTRIBUTION SWITCHBOARD
GRADE
GFP
1
NEW (OR EXISTING)PSE
4-WAY LOAD BREAKJUNCTION HUB
2
2
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
SP
AC
E
5
INTERIORNEMA 1
EXTERIORNEMA 3R
NEW 2000KVAPSE LOOPED UTILITY
TRANSFORMER
45,2
00
NEW / EXISTING SITE MEDIUM VOLTAGE FEEDER:
SIZED, PROVIDED AND PRICED BY PSEELBOW TERMINATION:
PROVIDED AND PRICED BY PSE
39,6
31
6
SP
AC
E
SP
AC
E
7
PH
ON
E (
253)
872-5
553
FA
X (
25
3)
87
2-4
112
KE
NT
, W
A 9
8032
7056 S
OU
TH
220T
H S
TR
EE
T
ELE
CT
RIC
IN
C.
SE
A T
AC
SCALE
DATE
DRAWN BY
CHECKED BY
PROJECT NUMBER
ww
w.s
eata
cele
ctric
.com
11/7
/2016 3
:06:4
6 P
M
12" = 1'-0"
C:\U
sers
\iane\D
ocum
ents
\VA
TL_A
_E
L_Ia
nE
dm
unds.r
vt
E5.01
ONE-LINE RISER DIAGRAM
T HE
VIL
LAG
E A
T TO
TEM
LA
KE
- B
LDG
A
KI R
KLA
ND
, WA
980
34
CM
CM, IE, NP
11/07/2016
15115
90%
CD
SE
T
CENTERCAL PROPERTIES,LLC 1600 EAST FRANKLINEL SEGUNDO, CA 90245
GENERAL NOTES
1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MCFEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'SDISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS.
2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARDLAYOUT. SEE ELECTRICAL ROOMS OR PANEL LOCATIONS (SHEETE2.01-E2.08) AND PANEL SCHEDULES (SHEET E5.02-E5.03) FORPHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED ANDPOTENTIAL INSTALLED CONDITIONS.
3. EQUIPMENT SHOWN BOLD IS NEW.
4. EQUIPMENT SHOWN DASHED IS EXISTING.
5. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
6. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDERSHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERETHE POWER SUPPLY ORIGINATES PER NEC 408.4(B).
7. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION.
8. PROVIDE PULL BOXES AS REQUIRED BY THE NEC.
9. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELSAND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN.
10. THE ONE-LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THEACTUAL ROUTING OF RACEWAYS.
11. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONSFROM SECTION 1 TO SECTION 2.
12. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL ANDSWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARECIRCUIT BREAKERS.
FLAG NOTES
CONCRETE HOUSEKEEPING PAD UNDER TRANFORMER(S)/SWITCHBOARD(S)/ GENERATOR(S) TO BE PROVIDED BY OTHERS.REFER TO STRUCTURAL PLANS FOR INSTALLATION DETAILS.
CT ENCLOSURE/TERMINAL CABINET PER POWER COMPANYREQUIREMENTS.
NOT USED
NOT USED
(1) 1-1/2" EMT CONDUIT TO BE PROVIDED FROM ELECTRICAL ROOMAND TO BE CAPPED AT ROOF.
PER NEC 240.87, PROVIDE DOCUMENTATION OR METHOD TO REDUCECLEARING TIME FOR ARC ENERGY REDUCTION.
MAIN BONDING JUMPER TO BE PROVIDED BY GEAR MANUFACTURERAND SHALL COMPLY WITH NEC 250.102(C)(1) NOTE #1. IF THEUNGROUNDED SUPPLY CONDUCTORS ARE LARGER THAN 1100KCMILCOPPER OR 1750 KCMIL ALUMINUM, THE GROUNDED CONDUCTOR ORBONDING JUMPER SHALL HAVE AN AREA NOT LESS THAN 12.5% OFTHE AREA OF THE LARGEST UNGROUNDED SUPPLY CONDUCTOR OREQUIVALENT AREA FOR PARALLEL SUPPLY CONDUCTORS. THEGROUNDED CONDUCTOR OR BONDING JUMPER SHALL NOT BEREQUIRED TO BE LARGER THAN THE LARGEST UNGROUNDEDCONDUCTOR OR SET OF UNGROUNDED CONDUCTORS.
12" = 1'-0"
ONE-LINE RISER DIAGRAM
1
2
3
4
5
Line to Line RMS Fault at MAIN DISTRIBUTION... 39,631.45 Amps
Multiplier "M" = 1/(1+f) 0.876802
f-Factor 0.140508
Phase (1ph = 2, 3ph = 1.73) 1.73
Voltage (L-L) 480
Distance (Feet) 115
No. of Parellel Runs 6
Z /1000' @.85pf (NEC Table 9) 0.045
Conduit type (S=Steel, P=PVC) P
Conductor type (AL=Alum, CU=Copper) AL
Wire Size 750 kcmil
Starting Fault Value at UTILITY ===> 45200.00 Amps
Conductor
Calculation for Fault Value at MAIN DISTRIBUTION SWITCHBOARD
FAULT CURRENT @ UTILITY XFMR SECONDARY =========> 45200.00 Amps
VILLAGE AT TOTEM LAKE - BUILDING "A" FAULT CURRENT CALCULATION SUMMARY
12
11
10 -- -- -- -- ... SPACE --
9 -- -- -- -- ... SPACE --
8 -- -- -- -- ... SPACE --
7 -- -- -- -- ... SPACE --
6 -- -- -- -- ... SPACE --
5 -- -- -- -- ... SPACE --
4 -- -- -- -- ... SPACE --
3 -- -- -- -- ... SPACE --
2 -- -- -- -- ... SPACE --
1 -- -- -- -- ... SPACE --
CKT FRAME POLES FUSE A B C DESCRIPTION/NAMEPLATE NOTES
DISTRIBUTION SECTION No. 1
NOTES:
EST. DEMAND... 0 A
CONN. CURRENT: 0 A
EST. DEMAND LOAD: 0 VA
CONN. LOAD: 0 VA
LOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS
BLDG A - "MDS" 38"x28" MAIN... 0 VA
SWBD LOAD CONN. LOAD
LOAD SUMMARY
BLDG A - "MDS" 38"x28" DIST... 0 VA
DISTRIBUTION SUMMARY CONN. LOAD
2000 3
FRAME POLES FUSE SPECIAL DESCRIPTION/NAMEPLATE
MAIN DEVICE
CUSTOMER POWER QUALITY METER
C.T. COMPARTMENT: CURRENT TRANSFORMER, POTENTIAL TRANSFORMER
MAIN SECTION
BUS AMPS: 2000 SPECIAL:
MAIN DEVICE: MAIN CB AIC RATING: 42,000 AMPS SYMMETRICAL
LOCATION: MERCANTILE 4 VOLTAGE: 480Y/277V.3Ø4W.
SWITCHBOARD: MDS-A
Suitable as equipment feeder only. Not to be used for panel feeder
not be used for sizing parallel feeders. Load cannot exceed feeder ampacity
* - Indicates acceptable overcurrent device rating for single feeder. This rating shall
Chapter 9 - Table 4 and Table - 5.
NOTE: Based on NEC 2014, THHN insulation, EMT conduit and Annex C - Table C.10, or
200 (6) 3" 3-600kcmil, 1 #400 G. 2040/2000 75-deg rating
200N (6) 2 1/2" 4-600kcmil, 1 #400 G. 2040/2000 75-deg rating
160 (6) 2 1/2" 3-400kcmil, 1 #350 G. 1620/1600 75-deg rating
160N (6) 3" 4-400kcmil, 1 #350 G. 1620/1600 75-deg rating
150 (5) 3" 3-500kcmil, 1 #350 G. 1550/1500 75-deg rating
150N (5) 3" 4-500kcmil, 1 #350 G. 1550/1500 75-deg rating
120 (4) 3" 3-500kcmil, 1 #250 G. 1240 / 1200 75-deg rating
120N (4) 3" 4-500kcmil, 1 #250 G. 1240 / 1200 75-deg rating
100 (3) 3" 3-600kcmil, 1 #4/0 G. 1020 / 1000 75-deg rating
100N (3) 3 1/2" 4-600kcmil, 1 #4/0 G. 1020 / 1000 75-deg rating
90 (3) 3" 3-500kcmil, 1 #4/0 G. 930 / 900 75-deg rating
90N (3) 3" 4-500kcmil, 1 #4/0 G. 930 / 900 75-deg rating
80 (3) 2 1/2" 3-400kcmil, 1 #3/0 G. 810 / 800 75-deg rating
80N (3) 3" 4-400kcmil, 1 #3/0 G. 810 / 800 75-deg rating
75 (3) 2 1/2" 3-350kcmil, 1 #3/0 G. 750 / 750 75-deg rating
75N (3) 3" 4-350kcmil, 1 #3/0 G. 750 / 750 75-deg rating
60 (2) 3" 3-500kcmil, 1 #2/0 G. 620 / 600 75-deg rating
60N (2) 3" 4-500kcmil, 1 #2/0 G. 620 / 600 75-deg rating
50 (2) 2 1/2" 3-350kcmil, 1 #1/0 G. 500 / 500 75-deg rating
50N (2) 3" 4-350kcmil, 1 #1/0 G. 500 / 500 75-deg rating
45 (2) 2 1/2" 3 -300kcmil, 1 #1/0 G. 460 / 450 75-deg rating
45N (2) 2 1/2" 4 -300kcmil, 1 #1/0 G. 460 / 450 75-deg rating
40 (2) 2 1/2" 3 -250kcmil, 1 #1 G. 410 / 400 75-deg rating
40N (2) 2 1/2" 4 -250kcmil, 1 #1 G. 410 / 400 75-deg rating
34 3" 3-600kcmil, 1 #1 G. 340 / 300 75-deg rating
34N 3 1/2" 4-600kcmil, 1 #1 G. 340 / 300 75-deg rating
30 3" 3-500kcmil, 1 #2 G. 310 / 300 75-deg rating
30N 3" 4-500kcmil, 1 #2 G. 310 / 300 75-deg rating
27 2 1/2" 3-400kcmil, 1 #2 G. 270 / 250 75-deg rating
27N 3" 4-400kcmil, 1 #2 G. 270 / 250 75-deg rating
25 2 1/2" 3-350kcmil, 1 #2 G. 250 / 250 75-deg rating
25N 3" 4-350kcmil, 1 #2 G. 250 / 250 75-deg rating
22 2 1/2" 3 -300kcmil, 1 #2 G. 230 / 225 75-deg rating
22N 2 1/2" 4 -300kcmil, 1 #2 G. 230 / 225 75-deg rating
20 2 1/2" 3 -250kcmil, 1 #4 G. 205 / 200 75-deg rating
20N 2 1/2" 4 -250kcmil, 1 #4 G. 205 / 200 75-deg rating
18 2" 3 - #4/0, 1 #4 G. 180 / 175 75-deg rating
18N 2 1/2" 4 - #4/0, 1 #4 G. 180 / 175 75-deg rating
15 2" 3 - #3/0, 1 #4 G. 155 / 150 75-deg rating
15N 2" 4 - #3/0, 1 #4 G. 155 / 150 75-deg rating
13 2" 3 - #2/0, 1 #4 G. 135 / 125 75-deg rating
13N 2" 4 - #2/0, 1 #4 G. 135 / 125 75-deg rating
12 1 1/2" 3 - #1/0, 1#4 G. 120 / 110 75-deg rating
12N 2" 4 - #1/0, 1#4 G. 120 / 110 75-deg rating
10 1 1/2" 3 - #1/0, 1#6 G. 120 / 100 75-deg rating
10N 2" 4 - #1/0, 1#6 G. 120 / 100 75-deg rating
8 1 1/4" 3 - #1, 1#6 G. 85 / 80 60-deg rating
08N 1 1/4" 4 - #1, 1#6 G. 85 / 80 60-deg rating
7 1 1/4" 3 - #2, 1#6 G. 75 / 70 60-deg rating
07N 1 1/4" 4 - #2, 1#6 G. 75 / 70 60-deg rating
06 1 1/4" 3 - #3, 1#8 G. 65 / 60 60-deg rating
06N 1 1/4" 4 - #3, 1#8 G. 65 / 60 60-deg rating
05 1" 3 - #4, 1#8 G. 55 / 50 60-deg rating
05N 1 1/4" 4 - #4, 1#8 G. 55 / 50 60-deg rating
04 1" 3 - #6, 1#8 G. 40 / 40 60-deg rating
04N 1" 4 - #6, 1#8 G. 40 / 40 60-deg rating
03 3/4" 3 - #8 1#8 G. 30 / 30 60-deg rating
03N 3/4" 4 - #8, 1#8 G. 30 / 30 60-deg rating
ID NO RACEWAY WIRE COUNT & SIZE OCP SIZE NOTES
EMT AMPACITY/
FEEDER SCHEDULE ALUMINUM
6
No. Description Date
1 CITY OF KIRKLANDREVIEW COMMENTS
11/02/2016
71
1
11-8-2016
ENR16-08749Page 7 of 7
City of KirklandReviewed by J Tumelson11/22/2016
Supersededwith revision
dated 4/27/2017
ENR16-08749Revised Approved Plans
Page 1 of 1
City of KirklandReviewed by J Tumelson04/27/2017
SheetsE0.01 - SYMBOLS AND ABBREVIATIONSE0.02 - ELECTRICAL SCHEDULESE1.01 - ELECTRICAL SITE PLANE2.01 - LEVEL 1 POWER PLANE2.02 - MEZZANINE, ENLARGED ELECTRICAL ROOM, AND ENLARGED LOADING DOCK POWER PLANE2.03 - MAIN ROOF POWER PLANE5.01 - ONE-LINE RISER DIAGRAM