Synthesis and characterisation of pvc pipe 2

Post on 02-Dec-2014

158 views 0 download

description

THIS IS A (PROJECT PART 4)

transcript

G.S. Mandal’sMaharashtra Institute of Technology

AurangabadPlastics & Polymer Engineering Department

PROJECT on

SYNTHESIS AND CHARACTERIZATION OF PVC/HDPE PIPE

PRESENTED BY:-TARACHAND FULMALI (ROLL NO-T3704)VIVEK KARANJAWKAR (ROLL NO-T3726)BADAL PANCHAL (ROLL NO-T3730)CLASS :- TYPPEYEAR :-2013-2014

GUIDED BY:MR. MUJAHID. ANSARI

Assistant ProfessorM.I.T. (T), Aurangabad

AIM AND OBJECTIVES

As we know that when water from height are falling down in the pipe, it create sound which may disturb human beings .

Our main aim to reduce the sound which occurs during water flowing in the pipe.

Targeted remedies

By increasing the density of pipe.

By reducing coefficient of friction between inside wall of pipe and flowing water.

Pipe Extrusion

Machine description

PARTS OF EXTRUDER

MODIFIED FORMULATION OF PVC PIPE

INGREDIENT phr Kgs

PVC 100 25

TBLS 1 0.250

Lead Stearate 0.55 0.137

Calcium Stearate 0.45 0.112

Calcium carbonate 16 4

Wax 0.8 0.200

Stearic acid 1.2 0.300

Blue pigment 0.1 0.025

VISIT TO PIPE PLANT

Positive response from SAMRAT Pipe at Beed.They provide us raw material related to our recipe.

Weighing Ingredients Mixing

FeedingExtrusion

Cutting Dispatch

FLOW CHART OF PROCESS

TROUBLESHOOTING WE FACED…….

PROBLEM CAUSES REMEDIES

1. Material was not melt properly

1. Low temperature of barrel and die

1. Increased barrel and die temp.

2. Breaking of pipe 1. Low melt strength.

1. Reduced screw rpm.

2. Reduced speed of catterpillar

3. Flow lines 1. Poor mixing 1. Use correct screw design

INGREDIENT phr Kgs Cost/ kg Total cost

PVC 100 25 65 1625

TBLS 1 0.250

130 65Lead Stearate 0.55 0.112

Calcium Stearate

0.45 0.137

Calcium carbonate

16 4 10 40

Wax 0.8 0.200 20 4

Stearic acid 1.2 0.300 40 12

Blue pigment 0.1 0.025 5 0.050

COST ANALYSIS

Total cost :- Rs. 1746.05

TESTING OF PIPE

COMPRESSION TESTING

ASH CONTENT

DENSITY

IMPACT TESTING

HYDROSTATIC PRESSURE TESTING

ASH CONTENT (ASTM D 5630)

Result :- 13.75%

COMPRESSION TEST (ASTM D 695)

TESTING OF REFERENCE PIPE AND RESULT ANALYSIS…

NEW FORMULATION TOWARDS OUR AIM….