Post on 11-Oct-2018
transcript
TRO-REEL HS/HIGH SPEED (Non-Tension Type)
! Please follow the safety precautions on pages 2 and 3.
Indoor Use Insulated Trolleys・UL Listed UL
17
The V-shaped conductors provide a large contact surface area, ensuring a consistent power supply even at high speeds.
The conductors have a unique V shape that increases the contact area between the conductors and the collector arm.As a result, the power supply is consistent, even when the conveyors are travelling at high speeds, effectively preventing such problems as separation from wires.
An 8P installation measures only 124mm in height. Easy setup even in confined spaces.
For precision control of conveyers, use of multiple control wires is essential. With the Tro-Reel HS, even when 8P is installed, the height remains just 124mm. (Depending on the combination of components used, installations larger than 8P are also possible. For details, contact us.)
Easily adaptable to complex line configurations, such as sections with different voltages, insulated sections, turntables and traversers.
Installation of insulated sections and sections with different voltages is possible by simply inserting insulating pieces. By using a guide cap, the Tro-Reel HS can accommodate transfers between lines via turntables and traversers.
Easy installation of curved lines as tight as 800mm in radius.
Installation of curves with the Tro-Reel HS is very easy. The V-shaped conductor can be installed in curves as tight as 800mm in radius without the use of any special bending tools, so it's ideal even for complex layouts.
124A
Center feed-in joiner Guide cap
Guide cap
Guide cap(front-facing)
Guide cap(right-angled)
10~20mm
(right-angled)
(rear-facing)
500A
500 500
Over R800A
Hanger
The 3m long Tro-ReelHS units are installed
consecutively along the side of the rail.The units can manipulate motor conveyors through
complex linear routes at high speeds.
18
150130
500 26Cable AWG4 (22E)
1515
1515
1515
5.5
10 13
1515
1515 A
1515
15
Cable AWG8(8E)
TRO-REEL HS/HIGH SPEED (Non-Tension Type) Indoor Use Insulated Trolleys
90A Tro-Reel HS unit (for indoor use only) UL Listed Joiner UL Listed
●Rating ■600V, 90A●Conductor material ■Copper 28mm2
●Insulating sheath material ■Rigid PVC (heat resistance: 75°C)
Orange (hazard color), Munsell 2.5YR6/13
Ligth Blue, Munsell 5.5PB5.2/10
Used to connect the Tro-Reel HS units together. Joiners
allow for expansion and contraction of the Tro-Reel HS
units due to temperature fluctuations. Lock screw not
included.
Equipped with power supply cables. Simultaneously
supplies power and connects the Tro-Reel HS units
together. Lock screw not included.Note: Cannot be used as an end feed.
42
15 15
57
15 15 15
15 15 15 15
72
87
15 15 15 15 15
102
117
15 15 15 15 15 15
15 15 15 15 15 15 15
3P
4P
5P
6P
7P
8P
27.5 27.52997
150130
1515
1515
1515 5.
5
1013
26
1515
1515 A
1515
15
6
12
14
61
●Standard length is 3m, but units up to 6m available by special order.
Note: Please don’t use in the place where in high temperature and high humidity.
●Dimensions
Drawing shows an 8P joiner.
Drawing shows an 8P joiner.
Number of feedcables
The length of a feed cable is 500mm.
UL
Center feed-in Joiner UL Listed
ULULULULULUL
ULULULULULUL
Cat. No. Sheathcolor
OrangeLight Blue
Rating
600V90A600V90A
Standardlength
3m3m
Weight(kg)1.001.00
Units perbox——
Units percarton
2020
DH5801DH5801L
Cat. No. Rating A Weight(kg)
Units perbox
Units percarton
2P600V90A3P600V90A4P600V90A5P600V90A6P600V90A7P600V90A8P600V90A
3247627792
107122
0.140.170.220.280.340.390.45
1111111
40403020202020
DH5822DH5823DH5824KDH5825KDH5826KDH5827KDH5828K
Cat. No. Rating A Weight(kg)
Units perbox
Units percarton
2P600V90A3P600V90A3P600V90A1P600V30A3P600V90A2P600V30A3P600V90A3P600V30A3P600V90A4P600V30A3P600V90A5P600V30A
3247627792
107122
0.430.640.770.891.021.141.26
1111111
10101010101010
DH5862DH5863DH5864DH5865DH5866DH5867DH5868
22E 8E——12345
2333333
2P3P4P5P6P7P8P
19
Used to separate circuits by providing an insulated section
on the line. In addition to providing insulation between two
circuits, it feeds power to one of the separated circuits.
2615
10
98 500
AWG18(0.75E)
30(Insulated section)
Used to guide the collector arms from one straight
section to another via turntables and traversers. Also
used as an end cap for closing off the end of a Tro-
Reel HS unit.
B
26
35
15151515151515
10
A
Two M5 screws8A max. thread depth
Used to guide the collector arms from one curved
section to another via traversers. The end is a front-
facing 45° angle.
A15 15 15 15 15 15 15
3126
B Two M5 screws8A max. thread depth
35
56
42.5
17.5
45°
Used to guide the collector arms from one curved
section to another via and traversers. The end is a
rear-facing 45° angle.
A15 15 15 15 15 15 15
2526
35
503517.5
45°
B
Two M5 screws8A max. thread depth
Drawing shows an 8P guide cap.
Drawing shows an 8P guide cap.Drawing shows an 8P guide cap.
Guide cap(front-facing)
Guide cap(rear-facing)
Guide cap(front-facing)
Guide cap(rear-facing)
Insulating piece UL Listed UL
Guide cap (protrusive 45° cut) UL Listed Guide cap (withdrawn 45° cut) UL Listed
Guide cap (right-angle cut) UL Listed
Cat. No. Rating
300V1A
Weight(kg)0.03
Units perbox
1
Units percarton
60DH5886K
Cat. No. Type
For 2PFor 3PFor 4PFor 5PFor 6PFor 7PFor 8P
A
3247627792
107122
B
153045607590
105
Weight(kg)0.030.030.040.050.060.070.09
Units perbox
1111111
Units percarton
50503535202020
DH5832DH5833DH5834KDH5835KDH5836KDH5837KDH5838K
Cat. No. Type
For 2PFor 3PFor 4PFor 5PFor 6PFor 7PFor 8P
A
3247627792
107122
B
153045607590
105
Weight(kg)0.040.040.060.070.090.100.12
Units perbox
1111111
Units percarton
45453525151515
DH5842DH5843DH5844KDH5845KDH5846KDH5847KDH5848K
Cat. No. Type
For 2PFor 3PFor 4PFor 5PFor 6PFor 7PFor 8P
A
3247627792
107122
B
153045607590
105
Weight(kg)0.040.040.060.070.090.100.12
Units perbox
1111111
Units percarton
45453525151515
DH5852DH5853DH5854KDH5855KDH5856KDH5857KDH5858K
ULULULULULUL
ULULULULULULULULULULULUL
20
Unit:mm
B
A15 15 15 15 15 15 15
352513
Two M5 screws8A max. thread depth
Drawing shows an 8P hanger.
Hanger UL Listed
Attached to the moving equipment and used to supply power from the Tro-Reel HS
unit to the equipment. Mount rod and mount plate types are available to fit mounting
hardware.Length of lead wire 300A
The collector arms should be replaced when it wears down to the replacement indication line. Typical collector service life is approximately 20,000km.
Collector arms UL Listed
Cat. No. Type
For 2PFor 3PFor 4PFor 5PFor 6PFor 7PFor 8P
A
3247627792
107122
B
153045607590
105
Weight(kg)0.030.030.040.050.060.060.07
Units perbox
1111111
Units percarton
50503535202020
DH5872DH5873DH5874KDH5875KDH5876KDH5877KDH5878K
Cat. No. Type Rating Weight(kg)
Units perbox
Units percarton
Single (for mount rod)
Tandem (for mount rod)
Tandem (for mount plate)
Single (no saddle)
1P600V30A1P600V30A×21P600V30A×2
1P600V30A
0.140.230.230.11
1111
16161616
DH58901K1DH58911K1DH58912K1DH58920K1
Used to mount the Tro-Reel HS
units on the side of the rail.
Hangers should be used a t
intervals of 600mm or less on
straight sections and 500mm or
less on curved sections.Note: If installation is in a place directly
exposed to cutting oil or similar substances, please consult our Electrical Conduits and Wiring Materials Division.
●Single type (for mount rod) ●Single type (no saddle)
●Tandem type (for mount rod) ●Tandem type (for mount plate)
15
(180
)
4.5
30
65±
10(R
ange
of m
ovem
ent)
6 7
8587.2
65
R3.5-5S
14.8
R3.5-5S
6587.2
170270
76
65±
10(R
ange
of m
ovem
ent)
14.8
30
4.515
(180
)
R3.5-5S
30
76
65±
10(R
ange
of m
ovem
ent)
6587.2
170270
14.8
4.515
(180
)
R3.5-5S
6587.2
19
70
4.5
(180
)
15
76
60±
10(R
ange
of
mov
emen
t)
●Single type (for mount rod)
●Tandem type (for mount rod)
●Tandem type (for mount plate)
●Single type (no saddle)
Note: Does not include mount rod 12×12.
Note: Does not include mount rod 12×12.
Note: Does not include mount plate for mounting.
ULULULULULUL
UL
21
■TRO-REEL HS (Non-Tension Type)
120120120 100101P600V30A
Collector arm supporting components Collector (replacement part)
These components are mounted on the collector arm.
They keep the arm horizontal and minimize uneven abrasion of the collector shoe.
It is also possible to mount them on existing collector arms.
Typical collector service life is approximately
5,000km.
Sheath cutter
This labor-saving tool makes it possible to cut the insulating sheath of the Tro-
Reel HS units with just one hand.
8085
30
14.8
65±1
0(R
ange
of m
ovem
ent)
7
7
15
4590°15
●For single type (no saddle) ●For tandem type and single type (for mount rod)
●For tandem type (for mount plate)
※Two units are required when mounting on the tandem type.
Cat. No.
Cat. No.
Type
RatingSingle (no saddle)
Tandem, single (for mount rod)Tandem (for mount plate)
Weight(kg)
Weight(kg)
0.0130.0070.017 0.06
Units perbox
Units perbox
121212
Units percarton
Units percarton
DH58870DH58871DH58872 DH5883K
Conductor cleaner
This nylon brush is used to clean the
conductor surface of the Tro-Reel HS units.
Note: UL standards do not apply.Note: UL standards do not apply.
Note: UL standards do not apply. Note: UL standards do not apply.
Note: This collector is a replacement part for using collector arms which are of an earlier type than the collector arms listed on page 21 of this catalog.
Cat. No. Type
Single (for mount rod)
Weight(kg)0.11
Units perbox
1
Units percarton
16DH58851K1
Cat. No. Weight(kg)0.40
Units perbox
1
Units percarton
10DH5884K1
290
4.510065
Replacement line
300
7
4.5
3.5-5S
22
TRO-REEL HS (Non-Tension Type)■
Unit:mm