Turbine Inlet Cooling · Psychrometrics of Cooling Turbine Inlet Cooling: ASME Turbo Expo 2011...

Post on 28-Jul-2018

228 views 0 download

transcript

Psychrometrics of Cooling

Turbine Inlet Cooling:ASME Turbo Expo 2011

Presented by: Annette Dwyer

Munters Corporation

Psychrometrics

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity

Ratio, lb M

oisture/lb Dry A

ir

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity

Ratio, lb M

oisture/lb Dry A

ir

Rain or Fog

Saturation Line or

100% Relative Humidity

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity

Ratio, lb M

oisture/lb Dry A

ir

100%

50%

20%

10%

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030

Hum

idityR

atio, lb Moisture/lb D

ry Air

100%

50%

10%

20%

10 20 30 40 50 60 70 80 90 100 110 1200.000

0.005

0.010

0.015

0.020

0.025

0.030

Cool Heat

Dew Point Temperature (DP, ºF)The temperature at which existing moisture will condense from the air(forming dew)

Wet Bulb Temperature

Dry

Bul

b Te

mpe

ratu

re

Dew Point Temperature

100%

RH

10%

2030

40

50

60

80

70

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity

Ratio, lb M

oisture/lb Dry A

ir

20%

30%

RH

40%

RH

50%

RH

60%

RH

80%

RH

Measuring the Wet Bulb Temperature

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity

Ratio, lb M

oisture/lb Dry A

ir

100%

50%

20%

10%

2030

40

50

60

80

70

Wet Bulb Depression = 108 - 66

660

1080

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity R

atio, lb Moisture/lb D

ry Air

100%

50%

20%

10%

2030

40

50

60

80

70

Cooling = .90 X (108-66)

DIRECT EVAPORATIVE COOLING

70.2108

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidity R

atio, lb Moisture/lb D

ry Air

100%

50%

20%

10%

2030

40

50

60

80

70

780/91.6%

950/45%

1080/9%

70.20/81.2%

390/90%

680/20%

500 /87%

500/30%

A 90% Effective Evaporative Cooler Will Cool 90% of the Wet Bulb Depression

Regardless of the Starting Point

Hum

idity Ratio, lb M

oisture/lb Dry A

ir

Mechanical Cooling

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030

100%

50%

20%

10%

Warm Air Cool Air

2030

40

50

60

80

70

Chiller Coil

Las Vegas

Fort Myers

Chilled Coils

1000/700

Indirect Evaporative Cooling

2030

40

50

60

80

70

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidiity

Ratio, lb M

oisture/lb Dry A

ir

790 0

790/620

PrimaryAir Stream

10 20 30 40 50 60 70 80 90 100 110 1200.000

0.005

0.010

0.015

0.020

0.025

0.030

100%

50%

20%

10%

Secondary Air Stream Exhaust

Cold water

Warm water0 0Indirect /70100

/62

INDIRECT - DIRECT EVAPORATIVE COOLING

1000/700

63.7/0/62 0790/6201000/700

2030

40

50

60

80

70

75.2060.50

63.7/0/62.00

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidiity

Ratio, lb M

oisture/lb Dry A

ir

100%

50%

20%

10%Indirect

INDIRECTEVAPORATIVECOOLER

DIRECT EVAPORATIVECOOLER

Direct790/620

Direct Only

73º

INDIRECT - DIRECT EVAPORATIVE COOLING WITH CHILLED WATER ASSIST

1000/700

64.4/0/60.50790/630 75.2060.501000/700

2030

40

50

60

80

70

75.2060.50

64.4/0/61.50

10 20 30 40 50 60 70 80 90 100 110 120

Dry Bulb Temperature, Deg. F

0.000

0.005

0.010

0.015

0.020

0.025

0.030H

umidiity

Ratio, lb M

oisture/lb Dry A

ir

100%

50%

20%

10%IndirectCoil

INDIRECTEVAPORATIVECOOLER

IDXOR CWICOIL

DIRECT EVAPORATIVECOOLER

Direct

790/630

Psychrometrics of Cooling

Turbine Inlet Cooling:ASME Turbo Expo 2011

Presented by: Annette Dwyer

Munters Corporation