Utility Conductor/Wire Identification Guide - We … Conductor/Wire Identification Guide. TABLE OF...

Post on 10-Mar-2018

230 views 4 download

transcript

Utility Conductor/WireIdentification Guide

For more information or to report recovered material

We Energies Corporate Security Office 414-221-4024 (during normal business hours)

Central Alarm Station 414-221-4120 (after business hours)

Utility Conductor/W

ire Identification Guide

Trim cover insert to 9&3/8” x 11”

Spine 1” x 11”

Issued September 2007/Rev. 04-09

For more information or to report recovered material

We Energies Corporate Security Office 414-221-4024 (during normal business hours)

Central Alarm Station 414-221-4120 (after business hours)

Utility Conductor/Wire Identification Guide

TABLE OF CONTENTSSection 1 Aluminum Wire

Section 2 Copper Wire

Section 3 Miscellaneous

GLOSSARY

AcronymsACSR. Aluminum Conductor Steel Reinforced

AWG (American Wire Gauge). Standard measurement used to determine diameter

CN/JKT. Copper w/ nylon jacket insulation

HD. Wire was “hard drawn” during processing

SD. Wire was “soft drawn” during processing

XLPE. Cross linked polyethylene insulated

Other TermsAluminum Phase. High strength alloy

Bare. Wire does not have an insulating cover

Coated. Wire has an insulating cover.Electrical Current capacity. Designated by volts, i.e. 600v

Lot Number. Specific part number for ordering from manufacturer

Multiple cable assemblies. Designated by number and type of cable, i. e, 2 - #1/0, w/#2/0 neutral.

Resistance. Designated by KCM value (350, 336.4, 750, etc.)

Strands. The number of individual wires used in the cable.

Width of multi-strand conductor. Designated smallest to largest: #1/0, #2/0, #3/0 and #4/0.

Lot #101-8850

#6 AWG 7 Strand Aluminum Coated

#6 AWG 7 Strand Aluminum Coated

Lot #103-3441

#2 6/1 Strand ACSR Bare Aluminum

Lot #102-0978

300V 2 4/O XLPE Aluminum1 246.9 Aluminum Bare

300V 2 4/O XLPE Aluminum1 246.9 Aluminum Bare

Lot #102-1885

600V DB 2-350 AluminumPhase w/ #3/O Neutral

600V DB 2-350 Aluminum Phase w/ #3/O Neutral

Lot #102-0706

600V DB 3-#3/O Aluminum Phase w/ 1/O Neutral

Lot #101-9872

300V 2-1/O XLPE Aluminumand 1-123.3 Aluminum Bare

300V 2-1/O XLPE Aluminum and 1-123.3 Aluminum Bare

Lot #102-3870

600V DB 3-750 AluminumPhase w/ 350 Neutral

600V DB 3-750 AluminumPhase with 350 Neutral

Lot #103-5118

336.4 KCM 26/7 StrandACSR Bare Aluminum

Lot #102-0013

600V DB 2 - #1/O 19 StrandAluminum Phase CD

Lot #103-4308

#3/O 6/1 Strand ACSR Bare Aluminum

Lot #102-0587

600V DB 2- #3/O AluminumPhase w/ 1/O Neutral

Lot #101-9813

300V, 2 -#1/O Strand AluminumInsulated with Bare Neutral

300V 2-#1/O StrandAluminum Insulated with Bare Neutral

Lot #102-3811

600V DB (3) 750 KCM-61 Strand Aluminum Phase

Lot #101-9640

CN/JKT 15KV#2 Solid Aluminum Core

CN/JKT 15KV#2 Solid Aluminum Core

Lot #101-9690

CN/JKT 15KV #2 Solid Aluminum

CN/JKT 15KV #2 Solid Aluminum

Lot #103-3239

#4 7 Strand Copper600 V X-Linked Poly

Lot #103-3964

#1/0 19 Strand Copper600 V XLPE

Lot #103-2712

#6 SD Solid CopperWR Poly - Pole Grounds

Lot #103-4171

#4/O 19 Strand Copper600V XLPE

Lot #103-3891

1/0 7 Strand 3D CopperNon Coated BW

Lot #103-3859

#1/O 19 Strand Tinned Copper Coated Bonding

Lot #103-2755

#6 HD Solid CopperWR Poly - Pole Ground

Lot #103-4405

#4/O 7 Strand SD CopperNon Coated BW

Lot #101-2924

15KV #2 Stranded Copper

Lot #101-9920

600V 500 KCMIL 37 Strand

Lot #101-3874

14KVPaper Insulated - Lead Covered

Lot #103-4405

#4/0 Stranded Copper

Lot #103-3891

#1/0 7 Strand Copper - Steel Core

Lot #101-0475

Telephone 6 Pair

Lot #101-0480

Cable TV (Coax)

Lot #103-3280

#2 7-Strand, CU 600V XLPE

Lot #103-5266

350 KCM 37 StrandCU 600V XLPE

Lot #101-5295

500 KCMIL 28KV Copper

2” Copper Buss

4/O Bare Copper Ground

Lot #155-1302

Copper Ground Rod - Steel Core

Lot #103-0493

7 Strand Steel Guy Wire

#4/0 Copper TemporaryStation Ground