© 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x, D2x, F2x, G2x, 62x, J2x, L2x, 52x, M2x 8x 2.5” ODD optional/ LCD optional 8x 3.5” ODD optional/ LCD default 8x 2.5” ODD optional/ LCD optional 8x 3.5” ODD optional/ LCD default 12x 3.5” no ODD/no LCD 8x 2.5” no ODD/no LCD Upgradeable to 16x 2.5” ODD/LCD optional Upgradeable to 16x/24x 2.5” no ODD/no LCD Upgradeable to 16x 2.5” ODD/LCD optional No Rear HDD availab le Rear HDD availab le Rear HDD availab le
Transcript
Page 1: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation1

x3650 M5 Mechanical Base & Storage Upgrade

A2x

Sim

ple

Sw

ap(H

W R

AID

Up

gra

dea

ble

)S

tora

ge D

ense

(H

S)

Hot

Sw

ap

B2x

C4x

D4x

F4x

C2x, D2x, F2x, G2x, 62x, J2x, L2x, 52x, M2x

8x 2.5” ODD optional/ LCD optional

8x 3.5” ODD optional/ LCD default

8x 2.5” ODD optional/ LCD optional

8x 3.5” ODD optional/ LCD default

12x 3.5” no ODD/no LCD

8x 2.5” no ODD/no LCD

Upgradeable to 16x 2.5” ODD/LCD optional

Upgradeable to 16x/24x 2.5” no ODD/no LCD

Upgradeable to 16x 2.5” ODD/LCD optional

No Rear HDD

available

Rear HDD

available

Rear HDD

available

Page 2: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation2

x3650 M5 Storage Upgrade Path -Simple Swap

8x SFF SS HDD

SS backplate connected to HW RAID

8x SFF SS HDD

Non-RAID

SS backplate connected to onboard iPASS

Dedicated

A2x

8x LFF SS HDD

SS backplate connected to HW RAID

8x LFF SS HDD

NON-RAID

SS backplate connected to onboard iPASS

Dedicated

B2x

HW RAID Upgrade

(CTO/Option)

SS backplate connected to 2x HW RAID

Dedicated Riser1 slot 1

HW RAID Upgrade

(CTO/Option)

16x SFF SS HDD

Riser 1 needed

Option needed:1) HDD Kit OPT# 00MU1472) ServeRAID card

Option needed:1) HDD Kit OPT# 00MU147 x22) ServeRAID card x23) Riser 1 x1

Option needed:1) HDD Kit OPT# 00MU1482) ServeRAID card

+8 SFF HW RAID Upgrade

(CTO/Option)

Page 3: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation3

x3650 M5 Storage Upgrade Path -Hot Swap

16x SFF HS HDD

16x SFF HDD with two independent RAID

8x SFF HS HDD

C2x, D2x, F2x, G2x, 62x, J2x, L2x, 52x, M2x+8 SFF HDD

Upgrade(CTO/Option)

16x SFF HDD with expander & dedicated RAID

16x SFF HS HDD

Dedicated

1x8 Backplane

Dedicated

1x8 Backplane 1x8 Backplane

8x SFF HDD with dedicated RAID slot

Option needed:1) HDD Kit OPT# 00FK6762) ServeRAID card

Option needed:1) HDD Kit OPT# 00FK661

All support Rear 2.5” HDD

Rear 2.5” HDD

ServeRAID

Option needed:1) HDD Kit OPT# 00FK6582) ServeRAID M1215 OPT#46C9114

1x8 Backplane 1x8 Expander BP

Vertical slot 4

Dedicated

Page 4: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation4

x3650 M5 Storage Upgrade Path –Hot Swap

C4x8x LFF HS HDD

+2x Rear SFF with additional RAID controller (CTO/Option)

+2x Rear LFF with additional RAID controller (CTO/Option)

Dedicated

Option needed:1) HDD Kit OPT# 00FK6592) ServeRAID M1215 OPT#46C9114

Option needed:1) HDD Kit OPT# 00FK6582) ServeRAID M1215 OPT#46C9114

ServeRAID

2x4 Backplane

Rear 3.5” HDD

Rear 2.5” HDD

Vertical slot 4

ServeRAID

8x LFF HDD with dedicated RAID slot

Page 5: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation5

x3650 M5 Storage Upgrade Path -Storage Dense

D4x

Cascaded

Dedicated

+2x Rear SFF with additional RAID controller (CTO/Option)

+2x Rear LFF with dedicated +2x Rear SFF with additional RAID controller

(CTO/Option)

+2x Rear LFF with original dedicated RAID (CTO/Option)

12x LFF HS HDD

+2x Rear LFF with additional RAID(CTO/Option)

Vertical slot 4

Rear 3.5” HDD

Cascaded

ServeRAID

Rear 3.5” HDD

Rear 3.5” HDD

Rear 2.5” HDD

Rear 2.5” HDD

ServeRAID

ServeRAID

3x4 Backplane

Option needed:1) HDD Kit OPT# 00FK6592) ServeRAID M1215 OPT#46C9114

Option needed:1) HDD Kit OPT# 00FK659

Option needed:1) HDD Kit OPT# 00FK6582) ServeRAID M1215 OPT#46C9114

Option needed:1) HDD Kit OPT# 00FK659 2) HDD Kit OPT# 00FK6583) ServeRAID M1215 OPT#46C9114

12x LFF HDD with dedicated RAID slot

Without LCD Light Path module

Page 6: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation6

x3650 M5 Storage Upgrade Path -Storage Dense

16x SFF HDD with expander Without LCD Light Path module

+ x8 SFF HDD

+ x8 SFF HDD w/expander24x SFF HDD with expander & dedicated RAID (CTO/Option)

+ x8 SFF HDD w/ independent RAID

24x SFF HDD Triple independent RAID (CTO/Option)

24x SFF HDD with expander & dedicated RAID (CTO/Option)

16x SFF HDD Dual independent RAID (CTO/Option)

16x SFF HDD with expander & dedicated RAID (CTO/Option)

16x SFF HDD with Dual RAID Without LCD Light Path module

24x SFF HDD Dual independent RAID (CTO/Option)

8x SFF HDD with Single RAID Without LCD Light Path module

F4x

All support Rear 2.5” HDD

Rear 2.5” HDD

ServeRAID

Option needed:1) HDD Kit OPT# 00FK6582) ServeRAID M1215 OPT# 46C9114

1x8 Backplane 1x8 Backplane 1x8 Backplane

1x8 Backplane

1x8 Backplane

1x8 Backplane 1x8 Backplane

1x8 Backplane

1x8 Backplane

1x8 Backplane

1x8 Expander BP 1x8 Expander BP

1x8 Expander BP

1x8 Expander BP

OPT# 00FK661

OPT# 00FK661

OPT# 00FK661

OPT# 00FK676

OPT# 00FK676

OPT# 00FK676

Dedicated

Dedicated

Dedicated

Dedicated

Dedicated

Dedicated

Vertical Slot 4

Vertical Slot 4

Vertical Slot 4

**Check 3rd adapter rule

Page 7: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation7

x3650 M5 Storage Upgrade Path -2.5” HS HDD8 drive Model upgradable to maximum of 24 drives with Single RAID array

8x HS 2.5”

8 Drives – No Expanders

8x HS 2.5”

8x HS 2.5”

Backplane

+ Expander

16 Drives 24 Drives

8x HS 2.5”

Backplane

+ Expander

8x HS 2.5”

8x HS 2.5”

Backplane

+ Expander

To go from 8 to 16 drives, Add a first expander 8 pack

1) OPT# 00FK661

To go from 16 to 24 drives, Add a second expander 8 pack

1) OPT# 00FK661

1x8 Backplane

Dedicated slot

1x8 Backplane 1x8 Expander BP 1x8 Backplane 1x8 Expander BP 1x8 Expander BP

Dedicated slot

Page 8: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation8

x3650 M5 Storage Upgrade Path -2.5” HS HDD8 drive Model upgradable to maximum of 24 drives with Dual RAID array

8x HS 2.5”

8 Drives – No Expanders 16 Drives 24 DrivesTo go from 8 to 16 drives, Add a second 8 pack and a second ServeRAID adapter

1) OPT# 00FK6762) ServeRAID card

To go from 16 to 24 drives, Add a first expander 8 pack

1) OPT# 00FK661

8x HS 2.5”

8x HS 2.5”8x HS 2.5”

8x HS 2.5”

Backplane

+ Expander

8x HS 2.5”

1x8 Backplane 1x8 Backplane1x8 Backplane

Dedicated slot

1x8 Backplane1x8 Backplane 1x8 Expander BP

Dedicated slot

Dedicated slot

Vertical Slot 4

Vertical Slot 4

Page 9: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation9

x3650 M5 Storage Upgrade Path -2.5” HS HDD8 drive Model upgradable to maximum of 24 drives with Triple RAID array

8 Drives – No Expanders 16 Drives 24 Drives

8x HS 2.5”

To go from 8 to 16 drives, Add a second 8 pack and a second ServeRAID adapter

1) OPT# 00FK6762) ServeRAID card

To go from 16 to 24 drives, Add a third 8 pack, a third ServeRAID adapter, and a Riser8x HS 2.5”

8x HS 2.5”

8x HS 2.5”

8x HS 2.5”

8x HS 2.5”

1) OPT# 00FK6762) ServeRAID card3) Riser 1 or 2****the 3rd adapter rule

1x8 Backplane 1x8 Backplane1x8 Backplane 1x8 Backplane 1x8 Backplane 1x8 Backplane

Dedicated slot

Dedicated slot

Dedicated slot

Vertical Slot 4

Vertical Slot 4

**Check 3rd adapter rule

**Check 3rd adapter rule

CPU and Rear HDD 3rd adapter location

One CPU, No Rear HDD Slot 1

One CPU, with Rear HDD Not Support

Two CPU, No Rear HDD Slot 1

Two CPU, with Rear HDD Slot 6

Page 10: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation10

x3650 M5 Unique Ordering Information -CTOBase

(Front HDD)Disk Drive

Enablement KitODD &

LCD Light PathStorage Subsystem

8x 3.5” SS HDD (Non-RAID)

A5GA 00FK904

8x 3.5” SS HDD (RAID)

A5GC 00FK542

8x 3.5” HS HDD

A5GD 00FK905

12x 3.5” HS HDD

A5GE 00FK607

8x 2.5” SS HDD (Non-RAID)

A5G9 00FK903

8x 2.5” SS HDD (RAID)

A5GB 00FK624

8x 2.5” HS (Single RAID)

A5G6 00FK605

24x 2.5” HS (Single RAID)

A5G7 00FK900

8x 3.5” Base

A5FE 00FK597

12x 3.5” Base

A5FF 00FK598

2.5” Base

A5FD 00FK596

ODD Optional

LCD Light Path Default

ODD Optional

LCD Light Path Default

ODD N/A

LCD Light Path N/A

ODD Optional

LCD Light Path Optional

ODD N/A

LCD Light Path N/A

16x 2.5” HS (Dual RAID)

A5GG 00FK907

16x 2.5” HS (Single RAID)

A5GF 00FK906

24x 2.5” HS (Triple RAID)

A5G8 00FK902

24x 2.5” HS (Dual RAID)

A5TN 00KC643

Rear 2x 3.5” HDD (Cascade)

A5GL 00FK911

Rear 2x 3.5” HDD (RAID)

A5GK 00FK609

Rear 2x 2.5” HDD (RAID)

A5GH 00FK608

Rear 2x 2.5” HDD (RAID)

A5GH 00FK608

Only ONE RAID adapter allowed for rear HDDs.

16x 2.5” SS HDD (RAID)

A5GB x2 00FK624 x2

ODD/LCD Light Path Bay Optional

A5FY 00FK601

ODD Optional***

LCD Light Path Optional***

***ODD and LCD Light Path are optional when the Bay (A5FY/00FK601) selected.

Page 11: © 2014 IBM Corporation 1 x3650 M5 Mechanical Base & Storage Upgrade A2x Simple Swap (HW RAID Upgradeable) Storage Dense (HS) Hot Swap B2x C4x D4x F4x C2x,

© 2014 IBM Corporation11

x3650 M5 Rear HDDs Rules Only hot-swap HDD models can support rear HDD. Only front 3.5” HDD models can support rear 3.5” HDD. Only ONE RAID adapter allowed for rear HDD configurations, and this

one has to be ServeRAID M1215 (OPT#46C9114).


Recommended