4
VIDEOSCOPE
VIDEOSCOPE
Straightforward application,
unsurpassed image quality .........................41
VIDEOSCOPE
Diameter 3.8 – 8 mm,
working length 1 – 7.5 m.............................42
Diameter 5 – 8 mm,
working length 2 – 7.5 m, with 2-point
and multipoint measuring systems .............43
VIDEOSCOPE with working channel
Diameter 6.3 mm,
working length 2 – 7.5 m, with 2-point
and multipoint measuring systems .............44
VIDEOSCOPE Applications.........................45
Interchangeable Lenses for VIDEOSCOPE
Diameter 3.8 – 8 mm ...................................46
Accessories for VIDEOSCOPE ..............47-48
Camera Control Unit (PAL/NTSC) ...............49
LCD/VGA Flat Screen..................................50
Specifications..............................................51
Inspecting an engine with TECHNO PACK™ X
1-0
8
www.karlstorz.com
Endoscopes coupled with state-of-the-art CCD image
technology provide crystal-clear, true-color images.
Full-format images show the smallest details true to
life, enabling KARL STORZ to offer a new image quality
never previously thought possible.
Based on more than 60 years of experience in the
construction and design of optical components, the
VIDEOSCOPES delivers bright, brillant and high-
resolution images.
The function keys on the ergonomic handle are ideally
suited for single-hand control. The manual 4-way
deflection feature reacts directly to commands without
backlash or jerking movements.
Various interchangeable lenses with a locking
mechanism guarantee a complete view of all
inspection areas. A wide range of directions of view
and depth of field is provided. The lenses are available
in a range of working lengths ranging from 1 to 7.5 m
as well as diameters from 3.8 to 8 mm. Special units
can be obtained on request.
The models with working channels allow the insertion
of various tools or a magnet to grasp objects.
Product Features
– Ergonomically designed handle with 3 function keys,
integrated light transmission and video plug
– Minimum bend radius
– Full-screen image display
– 2- and 4-way deflection
– Compatible with all KARL STORZ products
– Smooth metal (Wolfram) or plastic outer coating
– Fastest digital measuring system on the market
(with 2-point or multipoint VIDEOSCOPES) in
combination with TECHNO PACK™ X
– Direct and tactile deflection without backlash
or jerking movements
Specifications see page 51
VIDEOSCOPE
Straightforward application, unsurpassed image quality
Adaption possibility for 7" monitor
Function keys for single-hand control
Modular sheath construction,
for cost-effective repairs
Optional: Integrated working
channel for working inserts
Lens with 2x safety thread, can be attached
manually or with a bayonet connection
Direct and tactile 2/4-way deflection
without backlash or jerking movements
41
4
V0800WDG 80135
3 (118.2)
4.5 (177.3)
2 (78.8)
1 (39.4)
3 (118.2)
2 (78.8)
3 (118.2)
2 (78.8)
1 (39.4)
81281101-401
81281101-403
81281101-402
81281011-403
81281011-402
81281011-401
81281111-403
81281111-402
81281111-401
V04010AH1) V04011AH1)81281001-401
81281001-403
81281001-402
81281001-504
81281001-503
81281001-502
81281101-504
81281101-503
81281101-502
Workinglength
m (inch)
VIDEOSCOPE
1) incl. Safety Adaptor V0400WAH for VIDEOSCOPE2) incl. Safety Adaptor V0800WAJ for VIDEOSCOPE
Inter-change-
able Lens
Toolfor Inter-change-
able Lens
SystemCase
De-flectionPAL
COLOR SYSTEMS/ORDER NO.
VIDEOSCOPE Kit consisting of :
NTSC
Dia.mm PAL NTSC
0° 90°
V04020AH1) V04021AH1)
V04030AH1) V04031AH1)
VM04010AH1) VM04011AH1)
VM04021AH1)VM04020AH1)
VM04030AH1) VM04031AH1)
V05020AE V05021AE
V05030AE V05031AE
V05040AE V05041AE
81281001-804
81281001-803
81281001-802
4.5(177.3)
3 (118.2)
2 (78.8)
81281101-804
81281101-803
81281101-802 V08020AG2) V08021AG2)
V08030AG2) V08031AG2)
V08040AG2) V08041AG2)
81281001-807
81281002-807
7.5(295.5)
7.5 (295.5)
81281101-807 V08070AG12) V08071AG12)
V08070AG22)
V0400A 80135V0403WDH
V0403WDH V0400A 80135
V0525WAE V0500AC 80135
2x3.8
2x4.2
4x5
4x8
4x8
V0800WDG 80135
VIDEOSCOPE with depth of field of 5 – 15 mm
www.karlstorz.com 1-0
842
VIDEOSCOPE
Diameter 3.8 – 8 mm, working length 1 – 7.5 m
Required to operate the VIDEOSCOPE:
– a camera control unit (see page 49)
and a light source (see chapter 8) or
– a mobile documentation unit
i.e. TECHNO PACK™ X (see chapter 3)
Order No.: = Plastic outer coating Order No.: = Metal outer coating (Wolfram)
3.8 – 4.2 mm
3.8 – 4.2 mm 5 – 8 mm
5 mm 8 mm
1) incl. Tool for Interchangeable Lens V0500AC2) incl. Validation Tool V0600V
Please note:
The VIDEOSCOPE kit does not include interchangeablelenses. These must be ordered separately.
Interchangeable lenses, 2-point or multipoint, see page 46
1-0
8
www.karlstorz.com43
4
Applications for VIDEOSCOPES with measuring
system:
Required to operate the VIDEOSCOPES
for measurements:
– a mobile documentation unit
TECHNO PACK™ X (see chapter 3)
– a 2-point or multipoint interchangeable lens,
see page 46
81281017-5041)
81281017-5031)
VP06021AEMV
VP06031AEMV
VP06041AEMV4.5(177.3)
3 (118.2)
2 (78.8)
81281115-6042)
81281115-6032)
81281115-6022)
81281015-6042)
81281015-6032)
81281015-6022) VP06020AEMV
VP06030AEMV
VP06040AEMV
6 80135
V05021AEMV
V05031AEMV
V05041AEMV4.5(177.3)
3 (118.2)
2 (78.8)
81281117-5041)
81281117-5031)
81281117-5021)81281017-5021) V05020AEMV
V05030AEMV
V05040AEMV
V08021AGMV
V08031AGMV
V08041AGMV
V08071AGMV
4.5(177.3)
7.5 (295.5)
3 (118.2)
2 (78.8)
81281117-804
81281117-807
81281117-803
81281117-802
81281017-804
81281017-807
81281017-803
81281017-802 V08020AGMV
V08030AGMV
V08040AGMV
V08070AGMV
4x8 80135
Workinglength
m (inch)
VIDEOSCOPE SystemCase
De-flectionPAL
COLOR SYSTEMS/ORDER NO.
VIDEOSCOPE Kit consisting of :
NTSC
Dia.mm PAL NTSC
4x5 80135
4x
VIDEOSCOPE
Diameter 5 – 8 mm, working length 2 – 7.5 m,
with 2-point or multipoint measuring systems
www.karlstorz.com 1-0
844
VIDEOSCOPE with Working Channel
Diameter 6.3 mm, working length 2 – 7.5 m,
with 2-point or multipoint measuring systems
V06071AEMV
V06021AEMV
V06031AEMV
V06041AEMV
7.5(295.5)
4.5 (177.3)
3 (118.2)
2 (78.8)
81281117-607
81281117-604
81281117-603
81281117-602
81281017-607 V06070AEMV
81281017-604
81281017-603
81281017-602 V06020AEMV
V06030AEMV
V06040AEMV
Workinglengthm (inch)
VIDEOSCOPE SystemCase
DeflectionPAL
COLOR SYSTEMS/ORDER NO.
VIDEOSCOPE-Set consisting of:
NTSC
Dia.mm PAL NTSC
4x6.3 80135
Please note:
The VIDEOSCOPE kit does not include interchangeablelenses. These must be ordered separately.
Interchangeable lenses, 2-point or multipoint,see page 46
F100 VIDEOSCOPE Kit
The KARL STORZ F100 VIDEOSCOPE Kit includes
a working channel videoscope and is 3 meters in
length.
The straightforward multipoint measuring system
can be used with this VIDEOSCOPE. The working
channel enables retrieval tools with diverse tips
(magnets, hooks, grasping forceps or snares) to be
inserted into the inspection area.
The working tools can be accessed at the
videoscope control body, saving significant time
and money.
Applications for VIDEOSCOPE with measuring
system:
Required to operate VIDEOSCOPES
for measurements:
– a mobile documentation unit
i.e. TECHNO PACK™ X (see chapter 3)
– a 2-point or multipoint interchangeable lens,
see page 46
The KARL STORZ F100 Kit (NSN # 6650-01-540-3603)
has been qualified by Pratt & Whitney Aircraft and the
United States Air Force.
1-0
8
www.karlstorz.com45
4
Inserts for VIDEOSCOPE with Working Channel
Grasping Forceps, with 3 spring-action claws
for 2 and 3 m VIDEOSCOPE, length 3.5 m V0603TPG
for 4.5 m VIDEOSCOPE, length 5 m V0605TPG
for 7.5 m VIDEOSCOPE, length 8 m V0608TPG
for 2 and 3 m VIDEOSCOPE, length 3.5 m
for 7.5 mVIDEOSCOPE,
length 8 m
for 4.5 mVIDEOSCOPE,
length 5 m
for 2 and 3 mVIDEOSCOPE,length 3.5 m
V0600TMV0600TMV0600TM
V0608TWAV0605TWAV0603TWA
V0603SB
for 4.5 m VIDEOSCOPE, length 5 m V0605SB
for 7.5 m VIDEOSCOPE, length 8 m V0608SB
Snares
Magnet (the magnet is attached to a spring retainer)
Magnet
Retainer
for 7.5 mVIDEOSCOPE,
length 8 m
for 4.5 mVIDEOSCOPE,
length 5 m
for 2 and 3 mVIDEOSCOPE,length 3.5 m
V0600THV0600THV0600TH
V0608TWAV0605TWAV0603TWA
Hook (the hook is attached to a spring retainer)
Hook*
* Order no. (V0600TH) includes 10 hook inserts.
Retainer
www.karlstorz.com 1-0
846
0°
8 mm(for measuringVIDEOSCOPE
only)
8 mm
6 mm
Product Features
– Interchangeable lens with direction of view 0°,
straight forward and 90° lateral
– Field of view from 30° to 100°
– Bayonet connection or 2x safety thread
– Depth of field from 1 mm to infinity
Note:
All multipoint measuring VIDEOSCOPES are delivered
without lenses.
5/6.3 mm
Interchangeable Lenses
for VIDEOSCOPE diameter 3.8 – 8 mm
7 – 80 mm50°90°
7 – 80 mm50°0°
�
�
�
20 – 80 mm70°90°
�20 – 80 mm70°0°
15 – 200 mm70°90°
�7 – 40 mm80°90°
�7 – 40 mm80°0°
�20 – 80 mm50°90°
25 – 200 mm50°90°
20 – 200 mm30°90°
�20 – 80 mm50°0°
1 – 15 mm100°90°
15 mm – infinity100°90°
25 – 200 mm30°0°
20 – 200 mm30°0°
1 – 15 mm100°0°
15 mm – infinity100°0°
7 – 80 mm50°90°
7 – 80 mm50°0°
�
�
�
20 – 80 mm50°90°
�7 – 40 mm80°90°
�7 – 40 mm80°0°
3 – 20 mm80°90°3.8/4.2 mm
Order no.VIDEOSCOPE
diameter
Directionof view
Field of view Depth of field2-point
measuringsystem
Multipointmeasuring
system
�20 – 80 mm50°
V0807WDEM
V0807WAEM
V0820WDGMV
V0820WAGMV
V0800WDG
V0607WDHMV
V0607WAHMV
V0620WDEMV
V0525WDE
V0520WDC
V0620WAEMV
V0501WDJ
V0515WDJ
V0525WAE
V0520WAC
V0501WAJ
V0515WAJ
V0507WDEM
V0507WAEM
V0520WDEMV
V0507WDHMV
V0507WAHMV
V0403WDH
V0520WAEMV
1-0
8
www.karlstorz.com47
4
Accessories for VIDEOSCOPE
Rigid Sleeves
Tools for Interchangeable Lenses
– Little effort required to change lens
– Easy to use
Validation tool for checking configuration settings
of 5, 6, 6.3 and 8 mm VIDEOSCOPE, measurement
interchangeable lenses and adjustment files.
Only in combination with TECHNO PACK™ X,
Software Version 1.18.4.4 and higher
6, 6.3 and 8 mm VIDEOSCOPES do not require tools
for changing lenses.
Product Features
– 360° rotating
– Can be used with 0° and 90° direction of view
– Tripod socket
600 mm 6.35 mm5 mmV05006AQ
300 mm 6.35 mm5 mmV05003AQ
600 mm 5.25 mm3.8 mmV04006AQ
300 mm 5.25 mm3.8 mmV04003AQ
Order no.VIDEO-
SCOPE dia.Workinglength
Outerdiameter
300 mm 7.50 mm6/6.3 mmV06003AQ
600 mm 9.35 mm8 mmV08006AQ
Validation Tool
V0400A
Tool for Interchangeable Lens
3.8/4.2 mm, for easy change of
3.8/4.2 mm interchangeable lenses
V0500AC
Tool for Interchangeable Lens
5 mm, for easy change of
5 mm interchangeable lenses
(included in delivery of 5 mm
VIDEOSCOPE)
V0500V
Validation Tool, for 5 mm
VIDEOSCOPE
V0600V
Validation Tool, for 6 and 6.3 mm
VIDEOSCOPES
V0800V
Validation Tool, for 8 mm
VIDEOSCOPE
www.karlstorz.com 1-0
848
Accessories for VIDEOSCOPE
VIDEOSCOPE Adaptor/Carrying Strap
80600
Multipurpose Stand,
for stable mounting of endoscopes and cameras
consisting of:
– Articulated stand with a joint in the center and ball
joints at both ends, equipped with a mounting plate
for holding a camera or endoscope grip, total length
approx. 50 cm
– Tripod (collapsible) for setting up the stand on an
even surface
– Tension rod with Vee guide for attaching the stand
to a circular pipe, or tabletop etc.
The stand can be moved in any direction and can be
locked into any position using a central lever.
80600H
Tension Rod, with Vee guide,
for attaching the VIDEOSCOPES
to the Multipurpose Stand 80600
V0X00H
VIDEOSCOPE Holder, with tripod
socket to screw in Multipurpose
Stand 80600 and a button for
attaching Carrying Strap 80404 G,
for all VIDEOSCOPE types
80404G
Carrying Strap for VIDEOSCOPE,
for VIDEOSCOPE Adaptor V0X00H
or direct attachment to
VIDEOSCOPE, length approx.
1.20 m, adjustable
1-0
8
www.karlstorz.com49
4
Product Features
– Waterproof
– Manual white balance
– For connection to LCD Flat Screen 80404
with 80404 K2 Cable
Specifications
Temperature range: 0 °C – +40 °C
Video connections:
Composite signal to BNC socket
Y/C signal to S-VHS socket
Accessories for connections:
ACC 1: 3.5 mm stereo jack plug 3-pin
ACC 2: 3.5 mm stereo jack plug 3-pin
Video output: Cinch socket
Power supply:
World power supply 85 – 264 V~, 47 – 440 Hz
Voltage output for external units:
4-pin Mini-DIN socket
Certified to: IEC 601-1, CE
Camera Control Unit (PAL/NTSC)
PAL NTSC
TECHNO VIDEOSCOPE Camera Control Unit
*CCU = Camera Control Unit
812810 01 81281101
TECHNO VIDEOSCOPE CCU* 81281020 81281120
Mains Cord 400F 400FUS
BNC/BNC Video Cable, length 180 cm 536MK 536MK
S-Video (Y/C) Connecting Cable, length 180 cm
Accessories (not included in delivery):
547S 547S
Adaptor, Schuko/US standard 1394990 1394990
S-Video (Y/C) Connecting Cable, length 350 cm 547SL 547SL
consisting of:
Color Systems:
www.karlstorz.com 1-0
850
LCD/VGA Flat Screen
80405VGA
VGA Flat Screen 7", high-resolution 800 x 600
VGA flat screen, for connection to TECHNO PACK™ X
and with videoscope adaptor, incl. cable, length 2 m
and tripod socket
80404
LCD Flat Screen 6.4", PAL/NTSC, portable,
adaptor to connect VIDEOSCOPE to VIDOSCOPE CCU
and TECHNO PACK II
consisting of:
80404 LCD LCD Flat Screen 6.4"
80404 C Cable Clips, package of 10
Specifications
Monitor: 7"
Resolution: VGA 800 x 600
Weight: 0.5 kg
Certified to: CE
Dimensions: 17.8 x 13.7 x 3 cm (w x h x d)
Specifications
Monitor: 6.4"
Resolution: 320 x 240
Color systems: PAL, NTSC
Weight: 0.78 kg
Certified to: CE
Dimensions: 16 x 14 x 3 cm (w x h x d)
Further accessories see pages 47-48
80405K5
Extension Cable, length 5 m, for connection
to 80405VGA and TECHNO PACK™ X
80404K2A
Extension Cable for 80404LCD, length 2.4 m,
to connect LCD flat screen to TECHNO PACK II
Accessories
80404K2
Extension Cable for 80404LCD, length 2.4 m,
to connect LCD flat screen to TECHNO PACK™
and VIDEOSCOPE CCU
80404K3
Extension Cable, length 3 m, to connect to 80404K2
1-0
8
www.karlstorz.com51
4
VIDEOSCOPE Diameter 3.8 – 8 mm
Specifications
VIDEOSCOPE Diameter 3.8 mm Diameter 5 mm Diameter 6 mm Diameter 6.3 mm Diameter 8 mm
Color systems PAL and NTSC
Function keys TECHNO PACK™ X settings: still images, video recording function, manual shutter setting,
measuring function, laser measuring system or HighGain and zoom function
Integration cable T-connector, integration cable 2.3 m, video cable 0.7 m
Deflection 2-way 4-way 4-way 4-way 4-way
up/down 180°/90° up/down 150°/150° up/down 150°/150° up/down 150°/150° up/down 120°/180°
right/left 120°/120° right/left 120°/120° right/left 120°/120° right/left 90°/90°
for 7.5 m, 40/90° for 7.5 m, 40/90°
Direction of view 0° standard, further directions of view for use with interchangeable lenses
Field of view 80° standard 50° standard, further fields of view 70° standard
for use with interchangeable lenses
Lens lock bayonet system bayonet system screw thread bayonet system screw thread
Screw thread triple safety triple safety double safety double safety double safety
Outer diameter of
distal tip diameter 3.9 mm diameter 4.9 mm diameter 6 mm diameter 6.3 mm diameter 8 mm
sheath diameter 3.8 mm diameter 5.1 mm diameter 6.3 mm diameter 6 mm diameter 8.1 mm
Working length 1000 mm 2000 mm 2000 mm 2000 mm 2000 mm
2000 mm 3000 mm 3000 mm 3000 mm 3000 mm
3000 mm 4500 mm 4500 mm 4500 mm 4500 mm
7500 mm 7500 mm
Minimal bend
radius
Sheath 40 mm 35 mm 35 mm 35 mm 80 mm
Lens 10 mm 15 mm 15 mm 15 mm 15 mm
Temperature range sheath in water +10°C – +30°C
sheath in air -10°C – +80°C
Resistance sheath resistant to gasoline, oil and machine oil; resistant in 5 % acid or caustic solution,
watertight up to 1 bar distribution pressure
Total weight 1000 mm 1 kg 2000 mm 1.1 kg 2000 mm 1.15 kg 2000 mm 1.1 kg 2000 mm 1.25 kg
2000 mm 1.1 kg 3000 mm 1.2 kg 3000 mm 1.25 kg 3000 mm 1.2 kg 3000 mm 1.35 kg
3000 mm 1.2 kg 4500 mm 1.55 kg 4500 mm 1.6 kg 4500 mm 1.55 kg 4500 mm 1.7 kg
7500 mm 2 kg
KARL STORZIndustrial Endoscopy
MEASUREMENT TECHNOLOGY
A modern endoscope must generate an imageof concealed body cavities as brilliant as possible. Decisive factors in this consideration are lightintensity, depth of focus, magnification, contrast and resolution.
The basis of an optimal image transmission inendoscopy was the introduction of the rod lenssystem by Professor Harold H. Hopkins, allowing a highly realistic image of the surfaceand structure of internal organs to be produced – this lens system has been subjected to continual further improvementand is setting standards worldwide.
Exact Measurement plays more and more animportant part during inspections. High accuracy, simple handling and fast measuring ensures during critical inspectionssaving time and money.
To get the point:
The high optical quality and the MultipointMeasurement Technology of KARL STORZendoscopes are a delight to all practitioners.
Optical elements for endoscopy Glass fibers provide the basis for the transmissionof light and images
Optical components are subjected to quality Computer-controlled quality assurance for the optical systems
Remote Visual Inspection Technology - we give you the answer -
Using KARL STORZ products is the best way to save time and money
Over 60 years of experience in developing lens systems helped us to create a brilliantcombination of Lens system and CCD chiptechnology. All Videoscopes with MultipointMeasurement Technology together with TECHNO PACK®X offer a unique combinationof brilliant optical lenses technology, Multipoint Measurement Technology andTECHNO PACK®X documenting software.
KARL STORZ employs this high quality andtechnology in one of the smallest compactsystem on the market.
Additionally TECHNO PACK®X offers a comparison measurement capability software.
One of the biggest benefit is that MultipointMeasurement System can inspect and measure all in one with no changing of tip: Only one tip is necessary. Accurately measure features and defects on a wide range of inspection targets
● “SEE and Measure” Function, only one tipnecessary
● No replacing of the Videoscope● No tip changing necessary● Easier handling guarantee saving money
and time● Accuracy of approx. 98% in every starting
position of the videoscopes ● Full screen function. No half images
as used for the stereo measurement technology
● Bright and sharp image with measurementtip
● TECHNO PACK®X Measurement Softwareguarantee results 3 to 4 times faster asother measurement systems
● Measurement Zoom for accurate cursorplacement
● Validation process to feedback correct configuration of individual system compo-nents, which allows a correct measurement
● Save measurement images with justificationtip data for future re-measurement. On TECHNO PACK®X Desktop Software
● Measurement results in millimetres orinches
Full image helps to find easily notches in the blades
Line to Point Measurement on the notch
Multipoint Measurement Technology System- your Advantages -
● Accuracy of approx. 98% in every startingposition of the videoscopes
● Accurate Measurement on curved and skewed edges
● 7 types of Multipoint Measurement● Distance (Length)● Depth
● Depth (Surface to Surface)● Depth (Point to Surface)● Depth (Point to Point)
● Line to Point or Point to Line ● Area incl. In-circle ● Multiline
● 4 types of Multipoint Measurement● Distance (Length)● Line to Point or Point to Line ● Area incl. In-circle ● Multiline
Measurement FeaturesPatent Multipoint Measurement Technology for accurate, simpler and fastermeasurement:
Line to Point Measurement with comments
Line to Point Measurement with comparison measurement
Overview of different mesurement types
Comparison measurement capability with TECHNO PACK®X features:
The TECHNO PACK®X Software algorithm analyses the position of each laser point andcalculates a 3D Image of the surface andreturns a high accuracy measurement result.
The Multipoint Measurement System uses a3D laser system with 49 laser points whichallows the camera in co-operation with the
Software to detect the surface structure of thesubject surface.
All multipoint measurements videoscopeobtain a laser, which allows the user to generate these 49 laser points. Four interchangeable measurement tips allow “SEE and Measure” Function.
Calculated algorithm analyse
Mutlipoint Measurement videoscope
How it works
Distal End
LaserProjector
Objective
Target
MeasuringItem
1. Set as much as possible laserpoints to the subject surface onwhich you want to measure
Hints:● Set Light source intensity to min.● Laser points should be clear and
sharp ● The object which you want to
measure should be set 1/3 of theimage size
2. Define the surface and activateModel
Hints: ● Z-Value helps to find the correct
settings
Z Value is the distance betweenLaserpoint ans Videoscope.
3. Select Measurement type and measure
Hints: ● Zoom can help for correct cursor
placement● The result will be displayed directly
in the field
Three easy steps to find the measurement result
Easy, fast and accurateKARL STORZ Multipoint Measurement Technology
Validation Process
The validation process is checking automatically the configuration between
●Videoscope
●Multipoint Measurement interchangeable tips
●Tips selection software file
●TECHNO PACK® X unit
The test conforms correct configuration of individualsystem components, which allows a correct measurement.The user gets information about the systems if they workcorrectly. If the result is negative the system automatically creates afailure code. This process is a unique function only offeredfrom KARL STORZ
The Validation process works only in connection to validation tool and TECHNO PACK® XSoftware Version 1.18.4.9 or higher.
Contact:KARL STORZ GmbH & Co. KG, Industrial Group
Mittelstraße 8, D-78532 Tuttlingen, Germany Tel.: +49 (0)7461 708-926Fax: +49 (0)7461 78912
E-mail: [email protected] Web: www.karlstorz.com
Repair Service:KARL STORZ GmbH & Co. KG
Repair Service Department - Industrial GroupDr.-Karl-Storz-Str. 34
D-78532 Tuttlingen, GermanyTel.: +49 (0)7461 708-926