7
® SPECIFICATION SUBMITTAL Page Job Name: Job Number: Model Numbers: Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller 369610a 1 07.18.12 Power Module The Power Module family is a group of modular products for the control of lighting loads. This document describes the following products: Model Number: LQSE-4S10-D - Power Module unit for Switching only Model Number: LQSE-4T10-D - Power Module unit for 0-10 V/Switching Features • Includes QS link for seamless connection to a HomeWorksR QS system. • Power Module units can be used in a HomeWorksR QS system to control and manage light in an entire home or building. MUX COM MUX QS Def Opt1 Opt2 0-10 V Power Module LQSE-4T10-D 230 V~ 50/60 Hz 50 mA www.lutron.com +44.(0)20.7680.4481 1 2 3 4 Outputs 230 V~ 10 AX each Zone 1 Zone 2 Zone 3 Zone 4 Option L N μ Z096 Opt3 CCI CCI COM 0,5 N•m All Others 8 mm 1,2 N•m Mains Only Input Hi Temp Program Power H M L Zones 0-10 V- 50 mA Up MUX COM MUX QS Def Opt1 Opt2 Switching Power Module LQSE-4S10-D 230 V~ 50/60 Hz 50 mA www.lutron.com +44.(0)20.7680.4481 1 2 3 4 Outputs 230 V~ 10 AX each Zone 1 Zone 2 Zone 3 Zone 4 Option L N μ Z096 Opt3 CCI CCI COM 0,5 N•m All Others 8 mm 1,2 N•m Mains Only Input Hi Temp Program Power H M L Up LQSE-4T10-D LQSE-4S10-D System Example QS Link Power Module Switching/0-10 V Power Module GRAFIK EyeR QS QS Contact Closure Interface HomeWorksR QS Processor HomeWorksR QS Wallstation SivoiaR QS Shades/Draperies Contact Closure Input Up to 100 total QS devices 230 V Control Power QS Power Supply (4) switched outputs, 10 AX each (zones 1-4) (4) 0-10 V outputs (zones 1-4) (model LQSE-4T10-D only)
Transcript
Page 1: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 1 07.18.12

Power ModuleThe Power Module family is a group of modular products for the control of lighting loads. This document describes the following products:

•Model Number: LQSE-4S10-D - Power Module unit for Switching only

•Model Number: LQSE-4T10-D - Power Module unit for 0-10 V/Switching

Features•IncludesQSlinkforseamlessconnectiontoaHomeWorksR QS system.

•PowerModuleunitscanbeusedinaHomeWorksR QS system to control and manage light in an entire home or building.

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

LUp

LQSE-4T10-D

LQSE-4S10-D

System Example

QSLink

Power ModuleSwitching/0-10 V

Power Module

GRAFIKEyeR QS

QS Contact Closure Interface

HomeWorksR QS

Processor

HomeWorksR QS Wallstation

SivoiaR QS Shades/Draperies

ContactClosureInput

Up to 100 total QS devices230 V

Control Power QS Power Supply

(4) switched outputs, 10 AX each (zones 1-4)

(4) 0-10 V outputs (zones 1-4) (model LQSE-4T10-D only)

Page 2: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 2 07.18.12

Specifications

Power

•230V 50/60 Hz•LightningstrikeprotectionmeetsANSI/IEEEstandard

62.31-1980. Can withstand voltage surges of up to 6 000 V and current surges of up to 3 000 A.

•Currentdraw:50mAmax•Standbypower:1W•BTUs/hourwhenfullyloaded:4

Output Zone Ratings

•Eachzoneisratedat10AXforswitching.Ratedforre-sistive, capacitive, or inductive lighting loads as defined byIEC/EN60669-2-1.

• Switched outputs utilize latching relays to maintain relay state if control power is lost.

• 0-10Vratedfor50mAmaximumoutput,sourceorsinkperzone.

Standards

•IEC/EN60669-2-1,EN50428•LutronQualitySystemsregisteredtoISO9001:2008•CE•C-TickS

Environment

•AmbientTemperatureOperatingRange(inside mounting panel): 0 ºC to 40 ºC

•Calibrationpointmaximum:65ºC•Relativehumidity:lessthan90%non-condensing•Forindooruseonly

Terminals

•Mainswiring:0,5mm2 to 6,0 mm2

•0-10VWiring:0,5mm2 to 2,5 mm2

•CCIWiring:0,5mm2 to 6,0 mm2

•Zonewiring:0,5mm2 to 6,0 mm2

Mounting

•UseanIP20(minimum)ratedconsumerpanelorbreakerpanelwithintegratedDINrail

•Width=9modules(161,7mm)

Programming and Compatibility Requirements

•LQSE-4T10-DandLQSE-4S10-DcanonlybeusedwiththeHomeWorksR QS system.

•SetupandprogrammingoftheDALIR Power Module isdonethroughtheHomeWorksR QS programming software.

•HomeWorks® QS software version 3,0 or higher required.

HomeWorksR QS Wallstations•HomeWorksR QS wallstations can be configured to

control Power Modules withtheHomeWorksR QS programming utility.

•LEDindicatordisplaysthestatusofprogrammedlights.

QS Link Limits

•AQSlinkinaHomeWorksR QS system can have up to 512 zones (outputs) and 100 devices.

•EachPowerModulecountsasonedevicetowardthe100 device limit.

Manual Mode Operation•Zonebuttons: — selects zone to control•Raise/Lowerbuttons: — turns loads on and off — dim loads up and down (LQSE-4T10-D only)

NOTE:Program,Input,andOptionbuttonsarenotused in LQSE models.

Contact Closure Input (CCI)

•TheCCIbehavesasaManualOverrideClosureInput.•IftheCCIisopen,thePowerModuleunitwillenterManualOverrideMode,whichwillturnonallloadsand disable control from other devices.

•WhentheCCIisclosedorjumpered(factorydefault),Power Module unit zones will return to the settings or levelstheywereatpriortoenteringManualOverrideMode.

Page 3: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 3 07.18.12

Overview of Wiring Terminals

MU

X

CO

M

MU

XQS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

LUp

Mains Wiring

Mains Wiring

QS Link

QS Link

Contact Closure

Input

Contact Closure

Input

Zone 1

Zone 1

Zone 1

Zone 2

Zone 2

Zone 2

Zone 3

Zone 3

Zone 3

Zone 4

Zone 4

Zone 4

0-10 V ChannelsLQSE-4T10-D

LQSE-4S10-D

Load power and switched outputs

Load power and switched outputs

IEC PELV

IEC PELV

Page 4: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 4 07.18.12

Mechanical Dimensions

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

ICCI

CO

M0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

LUp

LQSE-4T10-D

LQSE-4S10-D

161,7mm

60,6 mm

89,7mm

89,7mm

500-13431 Rev. B

N1771Z096

Page 5: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 5 07.18.12

Mains Voltage Wiring

Wiring from Distribution to Power Module unit

•TurnoffallcircuitbreakersorisolatorsfeedingthePower Module unit at distribution panel.

•Runlive,neutral,andearth( ) wires from a 230 V 50/60 Hz feed to the Power Module unit.

Mains Wiring and IEC PELV Separation

•Followappropriatelocalandnationalcodestoavoidviolating required separation guidelines.

Behavior During Power Failure

•RelaysdonotchangestatewhenpowerislosttotheL/N/ terminals. Follow local and national codes for emergency lighting requirements.

MU

X

CO

M

MU

XQS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

N

L

Live

Neutral

Switched Live

Zone1 example

SwitchedOutputs: 230 V

Load

NL

– Earth/Ground

– Neutral

– Mains/Live

Distribution Panel

Page 6: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 6 07.18.12

Wiring: 0-10 V

0-10 V Wiring (LQSE-4T10-D only)

•0-10 Vzones1-4aredouble-insulatedfromallotherinputs and outputs.

•0-10 Vzones1-4arenotinsulatedfromeachother.They share the same common (negative “–” terminal).

•ConnectonlySELV/IECPELVcircuits,orconnectonlynon-SELV/IECPELVcircuitsto0-10 Vzones1-4.DonotmixSELV/IECPELVcircuitsandnon-SELV/IECPELV circuits.

•Followallnationalandlocalelectricalcodesforseparation requirements.

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

Zone 1 Zone 2 Zone 3 Zone 4+ - + - + - + -

0-10 V Wiring

Wiring: Manual Override Contact Closure Input

IEC PELV Manual Override Contact Closure Input

•ContactClosureInput(CCI)wiringisIECPELV.Followall applicable national and local codes for proper circuit separation and protection.

•WheninManualOverridemode,allballastsandmoduleswillbeattheirprogrammedManualOverridelightlevel(defaultis100%).Allothercontrolsarelockedout.

•ManualOverridecontactclosureinputisnormallyclosed (NC). The Power Module unit is shipped with a jumperpre-installed.

Note: The Power Module unit will default to Manual OverrideModeiftheCCIisleftopen.IfnoManual Override contact input is required, please leave the wirejumperintheCCIterminals.

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

CCI Common

Page 7: 0-10 V / Switching Power Module Spec 369610a · Model Numbers: Switching0-10 V ... Outputs 230 V~ 10 AX each 1 2 3 4 Zone 1Z one 2Z 3Z one 4 Option L N ... 0 ºC to 40 ºC • Calibration

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller

369610a 7 07.18.12

Wiring: QS Link

IEC PELV QS Link Wiring

•LinkcommunicatesusingIECPELVwiring.

•Followallapplicablenationalandlocalcodesforproper circuit separation and protection.

•Wiringmaybedaisychainedort-tapped.

•TotallengthofQSlinkmustnotexceed600m.

•WireGauge: — Power (terminals 1 and 2): 1 pair 1,0 mm2 — Data (terminals 3 and 4): 1 pair 0,5 mm2 to

1,0 mm2, twisted and shielded. —CanuseLutroncableGRX-CBL-346S-500

•DoNOTconnectterminal2.

MU

X

CO

M

MU

X

QS

Def

Opt1

Opt2

0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481

1 2 3 4Outputs 230 V~ 10 AX each

Zone 1 Zone 2 Zone 3 Zone 4

Option

L N

µ

Z096

Opt3

CC

I

CCI

CO

M

0,5 N•mAll Others

8 mm1,2 N•mMains Only

Input

Hi Temp

Program

Power

H

M

L

Zones0-10 V-50 mA

Up

(1) COM(2) (no connection)

(3) MUX(4) MUX


Recommended