® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 1 07.18.12
Power ModuleThe Power Module family is a group of modular products for the control of lighting loads. This document describes the following products:
•Model Number: LQSE-4S10-D - Power Module unit for Switching only
•Model Number: LQSE-4T10-D - Power Module unit for 0-10 V/Switching
Features•IncludesQSlinkforseamlessconnectiontoaHomeWorksR QS system.
•PowerModuleunitscanbeusedinaHomeWorksR QS system to control and manage light in an entire home or building.
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
LUp
LQSE-4T10-D
LQSE-4S10-D
System Example
QSLink
Power ModuleSwitching/0-10 V
Power Module
GRAFIKEyeR QS
QS Contact Closure Interface
HomeWorksR QS
Processor
HomeWorksR QS Wallstation
SivoiaR QS Shades/Draperies
ContactClosureInput
Up to 100 total QS devices230 V
Control Power QS Power Supply
(4) switched outputs, 10 AX each (zones 1-4)
(4) 0-10 V outputs (zones 1-4) (model LQSE-4T10-D only)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 2 07.18.12
Specifications
Power
•230V 50/60 Hz•LightningstrikeprotectionmeetsANSI/IEEEstandard
62.31-1980. Can withstand voltage surges of up to 6 000 V and current surges of up to 3 000 A.
•Currentdraw:50mAmax•Standbypower:1W•BTUs/hourwhenfullyloaded:4
Output Zone Ratings
•Eachzoneisratedat10AXforswitching.Ratedforre-sistive, capacitive, or inductive lighting loads as defined byIEC/EN60669-2-1.
• Switched outputs utilize latching relays to maintain relay state if control power is lost.
• 0-10Vratedfor50mAmaximumoutput,sourceorsinkperzone.
Standards
•IEC/EN60669-2-1,EN50428•LutronQualitySystemsregisteredtoISO9001:2008•CE•C-TickS
Environment
•AmbientTemperatureOperatingRange(inside mounting panel): 0 ºC to 40 ºC
•Calibrationpointmaximum:65ºC•Relativehumidity:lessthan90%non-condensing•Forindooruseonly
Terminals
•Mainswiring:0,5mm2 to 6,0 mm2
•0-10VWiring:0,5mm2 to 2,5 mm2
•CCIWiring:0,5mm2 to 6,0 mm2
•Zonewiring:0,5mm2 to 6,0 mm2
Mounting
•UseanIP20(minimum)ratedconsumerpanelorbreakerpanelwithintegratedDINrail
•Width=9modules(161,7mm)
Programming and Compatibility Requirements
•LQSE-4T10-DandLQSE-4S10-DcanonlybeusedwiththeHomeWorksR QS system.
•SetupandprogrammingoftheDALIR Power Module isdonethroughtheHomeWorksR QS programming software.
•HomeWorks® QS software version 3,0 or higher required.
HomeWorksR QS Wallstations•HomeWorksR QS wallstations can be configured to
control Power Modules withtheHomeWorksR QS programming utility.
•LEDindicatordisplaysthestatusofprogrammedlights.
QS Link Limits
•AQSlinkinaHomeWorksR QS system can have up to 512 zones (outputs) and 100 devices.
•EachPowerModulecountsasonedevicetowardthe100 device limit.
Manual Mode Operation•Zonebuttons: — selects zone to control•Raise/Lowerbuttons: — turns loads on and off — dim loads up and down (LQSE-4T10-D only)
NOTE:Program,Input,andOptionbuttonsarenotused in LQSE models.
Contact Closure Input (CCI)
•TheCCIbehavesasaManualOverrideClosureInput.•IftheCCIisopen,thePowerModuleunitwillenterManualOverrideMode,whichwillturnonallloadsand disable control from other devices.
•WhentheCCIisclosedorjumpered(factorydefault),Power Module unit zones will return to the settings or levelstheywereatpriortoenteringManualOverrideMode.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 3 07.18.12
Overview of Wiring Terminals
MU
X
CO
M
MU
XQS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
LUp
Mains Wiring
Mains Wiring
QS Link
QS Link
Contact Closure
Input
Contact Closure
Input
Zone 1
Zone 1
Zone 1
Zone 2
Zone 2
Zone 2
Zone 3
Zone 3
Zone 3
Zone 4
Zone 4
Zone 4
0-10 V ChannelsLQSE-4T10-D
LQSE-4S10-D
Load power and switched outputs
Load power and switched outputs
IEC PELV
IEC PELV
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 4 07.18.12
Mechanical Dimensions
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
ICCI
CO
M0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
Switching Power ModuleLQSE-4S10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
LUp
LQSE-4T10-D
LQSE-4S10-D
161,7mm
60,6 mm
89,7mm
89,7mm
500-13431 Rev. B
N1771Z096
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 5 07.18.12
Mains Voltage Wiring
Wiring from Distribution to Power Module unit
•TurnoffallcircuitbreakersorisolatorsfeedingthePower Module unit at distribution panel.
•Runlive,neutral,andearth( ) wires from a 230 V 50/60 Hz feed to the Power Module unit.
Mains Wiring and IEC PELV Separation
•Followappropriatelocalandnationalcodestoavoidviolating required separation guidelines.
Behavior During Power Failure
•RelaysdonotchangestatewhenpowerislosttotheL/N/ terminals. Follow local and national codes for emergency lighting requirements.
MU
X
CO
M
MU
XQS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
N
L
Live
Neutral
Switched Live
Zone1 example
SwitchedOutputs: 230 V
Load
NL
– Earth/Ground
– Neutral
– Mains/Live
Distribution Panel
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 6 07.18.12
Wiring: 0-10 V
0-10 V Wiring (LQSE-4T10-D only)
•0-10 Vzones1-4aredouble-insulatedfromallotherinputs and outputs.
•0-10 Vzones1-4arenotinsulatedfromeachother.They share the same common (negative “–” terminal).
•ConnectonlySELV/IECPELVcircuits,orconnectonlynon-SELV/IECPELVcircuitsto0-10 Vzones1-4.DonotmixSELV/IECPELVcircuitsandnon-SELV/IECPELV circuits.
•Followallnationalandlocalelectricalcodesforseparation requirements.
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
Zone 1 Zone 2 Zone 3 Zone 4+ - + - + - + -
0-10 V Wiring
Wiring: Manual Override Contact Closure Input
IEC PELV Manual Override Contact Closure Input
•ContactClosureInput(CCI)wiringisIECPELV.Followall applicable national and local codes for proper circuit separation and protection.
•WheninManualOverridemode,allballastsandmoduleswillbeattheirprogrammedManualOverridelightlevel(defaultis100%).Allothercontrolsarelockedout.
•ManualOverridecontactclosureinputisnormallyclosed (NC). The Power Module unit is shipped with a jumperpre-installed.
Note: The Power Module unit will default to Manual OverrideModeiftheCCIisleftopen.IfnoManual Override contact input is required, please leave the wirejumperintheCCIterminals.
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
CCI Common
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Switching/0-10 V Power Module LQSE-4 Switching / 0-10 V Fixture Controller
369610a 7 07.18.12
Wiring: QS Link
IEC PELV QS Link Wiring
•LinkcommunicatesusingIECPELVwiring.
•Followallapplicablenationalandlocalcodesforproper circuit separation and protection.
•Wiringmaybedaisychainedort-tapped.
•TotallengthofQSlinkmustnotexceed600m.
•WireGauge: — Power (terminals 1 and 2): 1 pair 1,0 mm2 — Data (terminals 3 and 4): 1 pair 0,5 mm2 to
1,0 mm2, twisted and shielded. —CanuseLutroncableGRX-CBL-346S-500
•DoNOTconnectterminal2.
MU
X
CO
M
MU
X
QS
Def
Opt1
Opt2
0-10 V Power ModuleLQSE-4T10-D230 V~ 50/60 Hz 50 mAwww.lutron.com +44.(0)20.7680.4481
1 2 3 4Outputs 230 V~ 10 AX each
Zone 1 Zone 2 Zone 3 Zone 4
Option
L N
µ
Z096
Opt3
CC
I
CCI
CO
M
0,5 N•mAll Others
8 mm1,2 N•mMains Only
Input
Hi Temp
Program
Power
H
M
L
Zones0-10 V-50 mA
Up
(1) COM(2) (no connection)
(3) MUX(4) MUX