313
42
Pressure Boosting SetsPressure Boosting SetsFixed speed pump unitsVariable speed pump units with frequency converter
carlottaCasella di testo05/2010
314
Pressure Boosting SetsPressure Boosting Sets
020
8 12 16 20 24 28
30
90
m /h
m
50
60
70
80
H
Q 3
020 2 4 6 8 10
30
70
m /h
m
50
60
H
Q 3
Constant pressure boosting sets with Variomat frequency converterwith 1 MXH, MXSU, MXVB
VARIOMAT
Constant pressure boosting sets with Variomat frequency converterwith 2 MXH, MXSU, MXVB
VARIOMAT
NMD
MXHMXP
NM
NGXNG
10 20
50
70
40302010
0 280
2 4 816
H
m /h3Q
m MXH
10 2020
4050
100
m 25-2.. 32-4.. 40-8.. 50-18..
1 2 3 4 305
30
m /h3Q
HMXV-B
20 40
50
70
40302010
0 360
2 4 816
H
m /h3Q
m MXH
20 4020
4050
100
m 25-2.. 32-4.. 40-8.. 50-18..
2 5 6010
30
m /h3Q
HMXV-B
NMD
MXHMXP
NM
NGX
T,TP
NG
MINIMAT, TURBOMATCENTRIMAT, GETTOMATSmall automatic water systems with 1 pumpseries MXH, MXP, NM, NG, NGX
BS2FVariable speed pump pressure boostingsets for domestic usewith 2 MXH, MXP, NM, NG, NGX
BS1V1F, BS2VFixed speed pump pressure boostingsets for domestic usewith 2 MXH, MXP, NM, NG, NGX
PWM 230
MODE SET
Made in Italy
4.93.335.1
4.93.336.1
PWM 230
MODE SET
Made in Italy
PWM 230
MODE SET
Made in Italy
PWM 230
MODE SET
Made in Italy
PWM 230
MODE SET
Made in Italy
PWM 230
MODE SET
Made in Italy
PWM 230
MODE SET
Made in Italy
4.93.335.24.93.334.2
864
70
5040302010 100
24
H
m /h3Q
m MXSU
16128
70
5040302010 200
24
H
m /h3Q
m MXSU
315
Pressure Boosting SetsPressure Boosting Sets
42
2MXSU 4
2MXSU 2
0 248 12 16 20
20
30
50
70
60
Hm
2MXSU 8
10
0m /h3Q
3MXSU 4
3MXSU 2
0 3612 18 24 30
20
30
50
70
60
Hm
3MXSU 8
10
0m /h3Q
2 6 10 20 40 1001400
20
40
60
80
100
m /h3
m
Q
H
25-2 32-4 40-8 50-16 65-32 80-48
4 8 16 6432
BS2FVariable speed pump pressure boostingsets for civil use with 2 MXVB, MXV
BS1V1F, BS2VFixed speed pump pressure boostingsets for civil use with 2 MXVB, MXV
2 6 10 20 40 1001400
20
40
60
80
100
m /h3
m
Q
H
25-2 32-4 40-8 50-16 65-32 80-48
4 8 16 6432
Variable speed pump (on-board frequency converter) pressure boostingsets for civil use with 2 MXVE
BS1V1F, BS2V
2MXSU
3MXSU
BS2FVariable speed pump pressure boostingsets for domestic use with 2 MXSU
BS1V1F, BS2VFixed speed pump Pressure boostingsets for domestic use with 2 MXSU
BS3FVariable speed pump pressure boostingsets for domestic use with 3 MXSU
BS1V2F, BS3VFixed speed pump Pressure boostingsets for domestic use with 3 MXSU
2MXV
2MXVE
316
Pressure Boosting SetsPressure Boosting Sets
65/16
50M
65/250
65/200
80/250
80/16
80/200
50/16
50/20
50/25
40/16
40/20
40/25
32/16
32/20
32/210
320 Q m /h 40 60 80 100 20020
30
40
50
m
100
H
130
400
120100
50
40
30
2050 m /h 100 200 300 400 600
m 40/25
40/20 50/20
50/25
50/16
65/20 80/20
80/16
80/2565/25
40/16 65/16
50M
Q
H
3
0
20
40
60
80
100
mH
25-2 32-4 40-8 50-16 65-32 80-48
2 5 10 20m /h 5030 40 100 2003Q
0
20
40
60
80
100
mH
25-2 32-4 40-8 50-16 65-32 80-48
2 5 10 20m /h 5030 40 100 2003Q
3.93.115
BS3FVariable speed pump pressure boostingsets for civil use with 3 MXVB, MXV
BS1V2F, BS3VFixed speed pump pressure boostingsets for civil use with 3 MXVB, MXV
Variable speed pump (on-board frequency converter) pressure boostingsets for civil use with 3 MXVE
BS1V2F, BS3V
BS2FVariable speed pump pressure boostingsets for civil use with 2 NM, NMD
BS1V1F, BS2VFixed speed pump pressure boostingsets for civil use with 2 NM, NMD
BS3FVariable speed pump pressure boostingsets for civil use with 3 NM
BS1V2F, BS3VFixed speed pump pressure boostingsets for civil use with 3 NM
3MXVE
3MXV
3NM
2NM
317
42
Designation
BS M 2F 2 MXV 25/204
BS M 2V 2 MXV 25/204
Pump type
Pump type
Nr of pumps
Nr of pumps
Product series
2F
MTTT
3F1V1F1V2F2V3V
2 fixed speed pumps3 fixed speed pumps1 variable speed pump and 1 fixed speed pump1 variable speed pump and 2 fixed speed pumps2 variable speed pumps3 variable speed pumps
BS M 1V 1F 2 MXV 25/204
Sigle-phase supply(no indication: three-phase supply)
Sigle-phase supplyThree-phase supply
VARIOMAT series
2 MXH 204 - V MT2 MXH 204 - V TT
Product series
Tank capacity (litres)
With tank under the pump(no indication: tank above the pump)
Pump type
CENTRIMAT MXH 205E /24CENTRIMAT 1/1 MXH 205E /20
Pressure Boosting SetsPressure Boosting Sets
BSFwith fixed speed pumps
ConstructionPressure boosting sets with automatic opera-tion, consisting in 2 and 3 pumps on a com-mon baseplate, with sunction and deliverymanifolds, gate and non-return valves, pressu-re switches, pressure gauge, control paneland from 100 to 1000 litres diaphragm tank.
OperationThe control panel, with electronic card, mana-ges the pump operation, the changeover ofpump starting sequence and it stops thesystem when there is no air in the tank (paten-ted system).Pumps starting in a cascade sequence, with asignal from the pressure switches.
H
Q 3
BS 3F3 pompe a velocità fissa
H
Q 3
BS 2F2 pompe a velocità fissa
Stop
Start
Stop
Start
m
m /h
m
m /h
MINIMATwith 1 fixed speed pump
ConstructionSmall pressure boo-sting sets with automa-tic operation, consistingof pump, pressure swit-ch and 1 litre diaph-ragm tank.
OperationPump is directly driven by the pressure swit-ch.
TURBOMAT, CENTRIMAT,GETTOMATwith 1 fixed speed pump
ConstructionSmall pressure boosting sets with automaticoperation, consisting of with pump, pressureswitch, pressure gauge and diaphragm tank(24litres if above the pump, 20litres if underthe pump).
OperationPump is directly driven by the pressureswitch..
VARIOMATwith 1 variable speed pump
ConstructionPressure boosting setswith automatic operationand constant pressure,consisting of a variablespeed pump driven byVariomat frequency con-verter, with gate and non-return valves, pressuregauge, 8 litres diaphragmtank.
OperationVariable speed pump is directly driven byVariomat frequency converter.
VARIOMATwith 2 variable speed pumps
ConstructionPressure boosting sets with automatic opera-tion and constant pressure, made up with 2variable speed pumps on a common basepla-te driven by Variomat frequency converter,with suction and delivery manifolds, gate andnon-return valves, pressure gauge, 8 litresdiaphragm tank and control panel with twomagnetothermal switches.
OperationPumps starting in a cascade sequence, withchangeover of pump starting sequence.
BS 3F3 pompe a velocità fissa
BS 2F2 pompe a velocità fissa
F F
F FF
318
Operation
H
H setStop
Start
Q 3
VARIOMAT1 pompa a velocità variabile
H
Q 3
MINIMAT1 pompa a velocità fissa
m
m /h
m
m /h
F
1 l
F
Var.
H
H setStop
Start
Q 3
VARIOMAT1 pompa a velocità variabile
H
Q 3
MINIMAT1 pompa a velocità fissa
m
m /h
m
m /h
F
24 l
F F
Var. Var.
BS 2F2 fixed speed pumps
BS 3F3 fixed speed pumps
BS 2F2 fixed speed pumps
BS 3F3 fixed speed pumps
MINIMAT1 fixed speed pump
VARIOMAT1 variable speed pump
TURBOMAT, CENTRIMAT, GETTOMAT1 fixed speed pump
VARIOMAT2 variable speed pumps
BSV.F.with variable and fixed speedpumps (frequency converterinto the control panel)
ConstructionPressure boosting sets with automa-tic operation, consisting of 1 variablespeed pump with frequency conver-ter into the control panel and from 1to 5 fixed speed pumps, assembledon a common baseplate, with suc-tion and delivery manifolds, gate andnon-return valves, pressure gauge,control panel and 20 litres diaph-ragm tank.
OperationThe control panel, with electronic card,manages the pump operation, the changeo-ver of fixed speed pumps starting sequencePumps starting is in a cascade sequence,with a signal from the pressure transdu-cer.Constant pressure is guaranteed by thevariable speed pumps, while fixed speedpumps start when the request is higher thanthe capacity of the variable speed pump.
BSVwith variable speed pumps(frequency converter into thecontrol panel)
ConstructionPressure boosting sets with auto-matic operation, consisting ofvariable speed pumps (from 1 to 6)with frequency converter on thecontrol panel, assembled on acommon baseplate, with suctionand delivery manifolds, gate andnon-return valves, pressure tran-sducer, pressure gauge, controlpanel and 20litres diaphragmtank.ri.
OperationThe control panel, with electroniccard, manages the pump opera-tion, the changeover of pumpsstarting sequence.Pumps starting in a cascadesequence, with a signal from thepressure transducer.
319
BSV.F.with variable speed pumps(on board frequency converter)
ConstructionPressure boosting sets with automa-tic operation, consisting of 1 variablespeed pump with frequency conver-ter into the control panel and from 1to 5 fixed speed pumps, assembledon a common baseplate, with suc-tion and delivery manifolds, gate andnon-return valves, pressure gauge,control panel and 20 litres diaph-ragm tank.
OperationThe control panel, with electronic card,manages the pump operation, the changeo-ver of fixed speed pumps starting sequencePumps starting is in a cascade sequence,with a signal from the pressure transducer.Constant pressure is guaranteed by thevariable speed pumps, while fixed speedpumps start when the request is higherthan the capacity of the variable speedpump.
BSVwith variable speed pumps(on board frequency converter)
ConstructionPressure boosting sets with automa-tic operation, consisting of variablespeed pumps (from 1 to 6) with fre-quency converter on the controlpanel, assembled on a commonbaseplate, with suction and deliverymanifolds, gate and non-return val-ves, pressure transducer, pressuregauge, control panel and 20litresdiaphragm tank.
OperationThe control panel, with electroniccard, manages the pump opera-tion, the changeover of pumpsstarting sequence.Pumps starting in a cascadesequence, with a signal from thepressure transducer.
H
H set
Q 3
BS 1V2F3 pompe: 1 variabile
2 fisse
H
H set
Q 3
BS 1V1F2 pompe: 1 variabile
1 fissa
H
H set
Q 3
BS 3V3 pompe a velocità variabile
H
H set
Q 3
BS 2V2 pompe a velocità variabile
H
H set
Q 3
BS 1V2F3 pompe: 1 variabile
2 fisse
H
H set
Q 3
BS 1V1F2 pompe: 1 variabile
1 fissa
H
H set
Q 3
BS 3V3 pompe a velocità variabile
H
H set
Q 3
BS 2V2 pompe a velocità variabile
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
m
m /h
BS 1V2F2 pompe: 1 variabile
2 fisseBS 3V3 pompe a velocità variabile
BS 1V1F2 pompe: 1 variabile
1 fissaBS 2V2 pompe a velocità variabile
BS 1V2F3 pompe: 1 variabile
2 fisseBS 3V3 pompe a velocità variabile
BS 1V1F2 pompe: 1 variabile
1 fissaBS 2V2 pompe a velocità variabile
V F
V FF
V V
V VV
V F
V FF
V V
V VV
INVERTER INVERTER INVERTER
INVERTER INVERTER INVERTER INVERTER
BS 1V1F2 pumps: 1variable
1 fixedBS 2V2 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixedBS 2V2 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixedBS 3V3 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixedBS 3V3 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixedBS 2V2 variable speed pumps
BS 1V1F2 pumps: 1variable
1 fixedBS 2V2 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixedBS 3V3 variable speed pumps
BS 1V2F3 pumps: 1variable
2 fixedBS 3V3 variable speed pumps
42
Fixed speed pump units
New electrical control panelsfor fixed speed pump units.New electrical control panelsfor pressurisation units, all withelectronic card withmicroprocessors, formanaging pump operation.
The microprocessor carriesout continuous secure checksduring all the various workphases of the pumps andincorporates all necessaryfunctions, thus reducingelectrical and electroniccomponents inside the panel.
In particular:- pumps starting in a cascade sequence according to water demand.- changeover of pump starting sequence.- pumps stop when there is no water in the suction.- delay start-up of the 2nd/3rd pump in case of breakdown of pressure
switch 1 or after a power cut.- avoid pump starting in case of water hammering.- activate the alarm when pressure 1 fails.- activate the alarm when air cushion in the vessel drops.- stop the pump when air cushion is over*.* Patent pending
Maximum clarity for all signalsThe status of the unit can easily be identified on the front of the electroniccard with the following signals:- Power on led.- No water led.- Failure led.- Pump running led (1 for each pump).- Thermal block led (1 for each pump).- Pump automatic operation led (1 for each pump).- Pump stop led (1 for each pump).
Maximum simplicity of controlThe front of electronic card features the following signals and controls:- AUT-STOP push-button (1 for each pump)- MAN push-button (1 for each pump)- RESET push-button.
Optional remote controlThe new panels have been designed to remotely reproduce all theelectronic card signals (excluding the buttons), using RC 100 - RC 200 -RC 300 panels, connected with a simple two-pole cable.The RA 100 panel enables a remote warning light and acoustic signal.
Control panel for units up to 6 pumpsUsing the MPS 6000 (Multi Pumps System) electronic card it is possibleto control pressure units up to a maximum of 6 fixed speed pumps with asingle pressure calibration.
Automatic air supply systemsThe pump control panels are completed by microprocessor controlledsystems for automatic air supply in the pressure vessels by means of acompressor or solenoid valve.
OperationFor booster sets made up to three pumps:- according to the pressure decrease in the system, the pressure
switches make the pumps to start in cascade mode and the startingchangeover is made by the microprocessor.
For sets made of 4, 5, 6 pumps:- Operation controlled by a microprocessor with signal from a pressure
transducer. The pumps operate with only one pressure setting.
Variable speed pump units with frequencyconverterNew electrical control panelsfor variable speed pump units.New electrical control panelsfor pressurisation units withvariable speed pumps.These are indispensible in allthose cases where constantpressure is required and whenhigh pressure pumps are beingcontrolled.All the various working phasesare managed and controlled bythe MPS 6000 (Multi PumpsSystem) electronic card withmicroprocessor, which canoperate up to 6 pumpsworking simultaneously.
Maximum clarity of signalsAll the various calibration parameters appear as messages on thedisplay of the MPS 6000 electronic card.If there are any faults or defects a message appears on the displaygiving details of the problem.
Possibility of remote controlThe pump status can be displayed and the unit can be controlled bymeans of a special computer program.It is possible to obtain a remote warning light and acoustic signal on theRA 100 panel.
Constant or increased pressureAll the pumps can work with the same pressure value (set point), or, forsystems with high head losses, the pressure can be increased depen-ding on the number of pumps operating.
Silent operationMotors working at reduced speed and check valves that close gra-dually mean that operation is particularly quite.
Long life for pumpsAll the mechanical components of the pumps and motors are stressedto a minimum, due to the variable speed operation.
Energy savingsThe motors consume only the precise level of power necessary momentto moment, in order to supply the quantity of water required by thesystem.
No more high capacity vesselsThe use of inverters means that high capacity pressure vessels andmembrane vessels are no longer necessary. Even units with highflowrate pumps only require a small number of 20 litre membranevessels.
Great versatilityThe great versatility of the MPS 6000 electronic card enables the con-struction of special units with operational logics different from those ofnormal pressurisation units, depending on the requirements and characte-ristics of the systems.
OperationDepending on water consumption, one or more pumps are activated, all atvariable speed, in order to guarantee the quantity of water required atthe set pressure.
320
Pressure Boosting SetsPressure Boosting Sets