Module Objectives
After completing the module, the student will be able to:
Explain the need for signaling in telecommunication networks Describe ISO/OSI protocol model
Use protocol analyzer (in practice) to open traces and showsignaling messages
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
3/38
3 Nokia Siemens Networks Presentation / Author / Date / Document Number
What is signaling
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
4/38
4 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The importance of signaling
Signaling is an important part of a telephone call.
In the beginning signaling was just the common language used between
human operators in order to place and manage a voice call. Over the years, signaling methods were developed to properly send
automatic information on who the caller wants to call (the called party) andwho the caller is to the network (identification for billing).
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
5/385 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Signaling definition
In telecommunication, signaling isdefined as the exchange of informationbetween involved points in the network(switches or endpoints) that sets up,controls, and terminates each telephonecall.
Signaling is usually transferred from onepoint to the other in separate, dedicatedchannels.
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
6/386 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Protocols, Architectures, Interfaces
Signaling standards allow networkelements of different vendors to beconnected together.
Standard = protocols.
Protocols are described byspecifications.
For every telecommunication system
an architecture is defined. Thearchitecture shows the networkelements, their role and theconnections.
Connections between networkelements are called interfaces.
Each interface is a collection ofprotocols
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
7/387 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Frames, Messages, Procedures
Every protocol has its own structure,usually made of header, protocol dataand footer
Every protocol is like a differentlanguage with its own dictionary.
Wordsin the dictionaryare calledmessages.
A conversationis called procedure. Conversation can involve different
languages, i.e. procedures can usemessages from different protocols.
Header Protocol data Footer
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
8/38
8 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
What is protocol analyzer used for in everydaymaintenance?
Trouble
shooting
De
bugging
Multi
Vendor
Diagnose
Transmission
Subscriber
Trace
Tool
Network
Perfor
mance
Fault
Finding
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
9/38
9 Nokia Siemens Networks Presentation / Author / Date / Document Number
The ISO / OSI protocol stack model
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
10/38
10 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The importance of the OSI model
The OSI model divides the functions of a protocol into aseries of layers.
Each layer only uses the functions of the layer below,
Each layer only exports functionality to the layer above.
The group of these layers is known as a 'protocol stack' or'stack'.
Exceptions to stacks are called fast path and includeaspects of several layers.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
11/38
11 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 1: Physical Layer
The Physical layer defines all the electrical and physicalspecifications for devices. This includes the layout of pins,voltages, radio signal and cable specifications. Panels,repeaters, network adapters are physical-layer devices.
The major functions and services performed by the physicallayer are:
Medium synchronization.
Medium sharing. Modulation, or conversion.
In some cases Layer 1 is included in Layer 2 because thelogical link is sometimes strictly related to the way oftransmitting data.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
12/38
12 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 2: Data Link Layer 1/2
The Data Link layer provides the functional and proceduralmeans to transfer data between network entities.
Functions of the data link layer:
Framing. The data link layer divides the stream of bitsreceived from the network layer into data units called frames.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
13/38
13 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 2: Data Link Layer 1/2
The Data Link layer provides the functional and proceduralmeans to transfer data between network entities.
Functions of the data link layer:
Framing. The data link layer divides the stream of bitsreceived from the network layer into data units called frames.
Physical addressing. If frames are to be distributed todifferent systems on the network, the data link layer adds aheader to the frame to define the physical address of thesender (source address) and/or receiver (destination address)of the frame. If the frame is intended for a system outside thesenders network, the receiver address is the address of thedevice that connects one network to the next.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
14/38
14 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 2: Data Link Layer 1/2
The Data Link layer provides the functional and proceduralmeans to transfer data between network entities.
Functions of the data link layer:
Framing. The data link layer divides the stream of bitsreceived from the network layer into data units called frames.
Physical addressing. If frames are to be distributed todifferent systems on the network, the data link layer adds aheader to the frame to define the physical address of thesender (source address) and/or receiver (destination address)of the frame. If the frame is intended for a system outside thesenders network, the receiver address is the address of thedevice that connects one network to the next.
Flow Control. If the rate at which the data are absorbed bythe receiver is less than the rate produced in the sender, the
data link layer imposes a flow control mechanism to preventoverwhelming the receiver.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
15/38
15 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 2: Data Link Layer 2/2
Functions of the data link layer (cont.):
Error control. The data link layer adds reliability to the physicallayer by adding mechanisms to detect and retransmit damaged orlost frames. Error control is normally achieved through a trailer tothe end of the frame.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
16/38
16 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 2: Data Link Layer 2/2
Functions of the data link layer (cont.):
Error control. The data link layer adds reliability to the physicallayer by adding mechanisms to detect and retransmit damaged orlost frames. Error control is normally achieved through a trailer tothe end of the frame.
Access Control. When two or more devices are connected to thesame link, data link layer protocols are necessary to determinewhich device has control over the link at any time.
The data link layer is usually divided into two sublayers The MAC (Media Access Control) sublayer controls how a
computer on the network gains access to the data and permissionto transmit it.
The LLC (Logical Link Control) sublayer controls framesynchronization, flow control and error checking.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
17/38
17 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 3: Network Layer
The Network layer is responsible for the source-to-destination delivery of a packet possible across multiple
networks, adding a proper header.
Functions of the network layer:
Logical addressing: usually independent from thephysical (hardware) address
Routing: i.e. finding the way to reach the destination.
Internetworking A typical example is the IP (Internet Protocol)
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
L T L
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
18/38
18 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 4: Transport Layer 1/2
The transport layer is responsible for process-to-processdelivery of the entire message, that is from software to
software at the two ends of the communication.
The functions of the transport layer are:
Port or protocol addressing: computer or networkelements often run several processes (running programs)at the same time. Process-to-process delivery meansdelivery from a specific process on one computer to a
specific process on the other.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
L 4 T L 1/2
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
19/38
19 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 4: Transport Layer 1/2
The transport layer is responsible for process-to-processdelivery of the entire message, that is from software to
software at the two ends of the communication.
The functions of the transport layer are:
Port or protocol addressing: computer or networkelements often run several processes (running programs)at the same time. Process-to-process delivery meansdelivery from a specific process on one computer to a
specific process on the other. Flow control: the transport layer performs a flow control
end to end. The data link layer performs flow controlacross a single link.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
L 4 T t L 1/2
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
20/38
20 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 4: Transport Layer 1/2
The transport layer is responsible for process-to-processdelivery of the entire message, that is from software to
software at the two ends of the communication.
The functions of the transport layer are:
Port or protocol addressing: computer or networkelements often run several processes (running programs)at the same time. Process-to-process delivery meansdelivery from a specific process on one computer to a
specific process on the other. Flow control: the transport layer performs a flow control
end to end. The data link layer performs flow controlacross a single link.
Error control: the transport layer performs error controlend to end. The data link layer performs control across a
single link.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
L 4 T t L 2/2
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
21/38
21 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 4: Transport Layer 2/2
Functions of Transport Layer (cont.):
Segmentation and reassembly: a message is divided intotransmittable segments, each having a sequence number.
Connection control: The transport layer can be eitherconnectionless or connection-oriented.
A connectionless transport layer treats each segment as anindependent packet and delivers it to the transport layer at thedestination machine.
A connection-oriented transport layer makes a connection withthe transport layer at the destination machine first beforedelivering the packets.
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
Layer 5 Session Layer
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
22/38
22 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 5: Session Layer
The Session layer controls the dialogues (sessions)between computers.
It establishes, manages and terminates the connectionsbetween the local and remote application.
It provides for either duplex or half-duplex operation andestablishes check pointing, update, termination, and restartprocedures.
This layer is often removed or merged with Layer 5 or withLayer 7
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
Layer 6: Presentation Layer
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
23/38
23 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 6: Presentation Layer
The presentation layer was designed to handle the syntaxand semantics of the information exchanged between the
two systems. It was designed for data translation, encryption, decryption,
and compression.
The Presentation layer transforms data to provide astandard interface for the Application layer.
MIME encoding, data compression, data encryption andsimilar manipulation of the presentation is done at this layerto present the data as a service or protocol developer seesfit.
Examples: converting an EBCDIC-coded text file to anASCII-coded file, or serializing objects and other data
structures into and out of XML. This layer is often removed or merged in Layer 7
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
Layer 7: Application Layer
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
24/38
24 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 7: Application Layer
The Application layer is closest to the end user (human orautomatic).
It provides a means for the user to access information onthe network through an application.
This layer is the main interface for the user(s) to interactwith the application and therefore the network.
Some examples of application layer protocols include
Telnet, File Transfer Protocol (FTP), Simple Mail TransferProtocol (SMTP) and Hypertext Transfer Protocol (HTTP).
7. Application
6. Presentation
5. Session
4. Transport
3. Network
2. Data Link
1. Physical
The stack of layers
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
25/38
25 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The stack of layers
The seven layers weredesigned as a stack of
layers. Data flows from user to
user through all thelayers (if present)
Every entity at thesame layer is virtuallyconnected to the samelayer at the other end.
Network / User layers
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
26/38
26 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Network / User layers
Layers from 1 to 3 are usually referredto as
network layers,
sub-network layers, or
media layers.
Implementation of network layers isusually hardware based
Layers from 4 to 7 are referred to as user part layers,
application layers, or
host layers.
Implementation of application layers is
very often software based
Layer 5 to 7
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
27/38
27 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Layer 5 to 7
Layers 5 to 7 are usually represented and designed together because often theapplication also defines new formats and different ways of keeping track of
sessions. That is the reason why the application layer is often represented near the
transport layer
Headers
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
28/38
28 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Headers
Every protocol has its own headers and footers (or trailers)
From the application layer to the physical layer, many headers and footers areadded by every layer.
Header DATA Footer
Data units
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
29/38
29 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Data units
At every layer data units, or PDU(protocol data units) assume a
different name:
Data
Segment
Packet
Frame
Bits
A useful parallel
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
30/38
30 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
A useful parallel
Here is a useful parallelbetween ISO/OSI
network layers andsending a snail mail fromcompany to company.
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
31/38
31 Nokia Siemens Networks Presentation / Author / Date / Document Number
The tool to look at signaling
NetHawk Protocol Analyzer
The need for a protocol analyzer
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
32/38
32 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The need for a protocol analyzer
Telecommunication devices are usually connected by E1 cables where data flows in 32timeslots at a speed of 64kbps each.
In every timeslot flows user data or signaling. In some cases signaling links can havehigher (A or Gb) or lower speed (Abis).
Even at the lowest bit rate (8kbps), the information that flows in a signaling link is toomuch to be understood by a human being.
The signaling flow is therefore decoded and presented by a protocol analyzer.
Protocol analyzers are computer software (usually) or computer hardware that can
intercept and log traffic passing over a digital network or part of a network. As datastreams travel back and forth over the network, the analyzer captures each packet andeventually decodes and analyzes its content according to the appropriate protocol orother specifications.
Protocol analyzers are able to identify and show every message of every protocol fromthe interface they are set up for, without interfering with the actual transmission of thedata.
NetHawk
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
33/38
33 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
et a
Nokia co-operates with anotherFinnish company, vendor of protocol
analyzers: NetHawk. The NetHawk GSM Analyzer is an
effective and easy-to-use PC-basedprotocol analyzer for real-timemonitoring and analysis of GSM,GPRS and EDGE networks.
Learning how to use NetHawk is thebest way to learn signaling for Nokiacustomers because:
The layout is similar to Nokiaservice terminal extension forsignaling.
The software can be used freely inoff-line mode without the NetHawkinterface adapters.
How to start
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
34/38
34 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
For on-line monitoring you need a laptopequipped with a NetHawk N2 or a
desktop equipped with a NetHawk NAPcard.
Cards should be connected to patchpanels (or DDF) with proprietary cables.Extensions can easily deteriorate thesignal.
Impedance of the card should match theone of the monitored cable (75-120).
Impedance is set to HIGH not to disturbthe communication. It is set to LOW todivert signaling to the interface only(simulation).
Every card has its own HW id and SWid.
The software
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
35/38
35 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Both for on-line monitoring and for off-lineuse, a software is needed.
In case of on-line monitoring, the SW id ofthe installed software should match theSW id of the card in use.
The Protocol Info tab shows thespecifications used to decode themessages. These protocols should matchthe one used in the network element inorder to look at signaling closer to the realone.
User interface
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
36/38
36 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The user interface is made of
A menu bar
A toolbar with configurablebuttons
A monitoring window
A status bar with clickableindicators.
To work on-line
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
37/38
37 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
The first thing to check when workingon-line is if the signal is good or not
(open the State Monitor window) If not check the cables and the HWoptions of each connection.
Monitoring should be the same as inthe N2 hardware card. HIGH is normaluse.
Interface mode should be E1 in
Europe Condensed mode is not influent
SPEC should be ITU-T in Europe
Pointcode should be 14 in Europe
3GPP should be the same as in NE
Increasing the AGC maximum value
can decrease the CRC warnings. AGC is one per NAP card and is
automatically set.
In any case
7/31/2019 01 Rn2813-13n 01 Bsssig Overview
38/38
38 Nokia Siemens Networks BSSSIG / Author / May 2008 / Document Number
Both for on-line and off-line monitoringit is possible to specify the detail
shown per each layer. Both for on-line and off-line monitoring
it is possible to specify whichconnection to monitor and whatprotocol stack assume is flowingthrough it.