34
AIR DRYER 06| Reference Data [6] - 2 Refrigerated Air Dryer KDHR Air cooled [6] - 7 KDHR-W Water cooled [6] - 11 KDHT High temperature [6] - 12 Desiccant Air Dryer KDAH Heatless [6] - 13 KDAE Heater [6] - 14 KDAE-S Heater, skid [6] - 15 KDAO Oiless [6] - 16 KDAB Heater blower [6] - 17 KDNP Non-purge [6] - 18 KDH-C After Cooler [6] - 19 KDRC Chiller [6] - 20 SEPREMIUM Oil-Water Separator [6] - 21 KDRT Receiver Tank [6] - 22 KDHAD Auto Drain Trap [6] - 23 EZ-1 Electrical Trap [6] - 24 KDXF Filter [6] - 25 KDXE Filter Element [6] - 34
Transcript
Page 1: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

AIR DRYER06|

Reference Data [6] - 2

Refrigerated Air Dryer

KDHR Air cooled [6] - 7

KDHR-W Water cooled [6] - 11

KDHT High temperature [6] - 12

Desiccant Air Dryer

KDAH Heatless [6] - 13

KDAE Heater [6] - 14

KDAE-S Heater, skid [6] - 15

KDAO Oiless [6] - 16

KDAB Heater blower [6] - 17

KDNP Non-purge [6] - 18

KDH-C After Cooler [6] - 19

KDRC Chiller [6] - 20

SEPREMIUM Oil-Water Separator [6] - 21

KDRT Receiver Tank [6] - 22

KDHAD Auto Drain Trap [6] - 23

EZ-1 Electrical Trap [6] - 24

KDXF Filter [6] - 25

KDXE Filter Element [6] - 34

Page 2: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com26 -

PNEUMATIC & HYDRAULIC

Refrigerated Type

Desiccant Type

R/D A/C A/D A B C D E F G H I

1. Food, beverage, dairy industry

2. Chemical (Clean transportation)

1. Hospital(Breathing system) Medical (Packing)

2. Photograph printing, Fiber

2. Powder coating

3. Measurement/Controlling Equipment

4. Common industry

5. Sand blasting

A/C R/D

C

C

C

F

D

E

E

B

G

G

H

I

Compressor

Refrigerated Air DryerAfter CoolerDesiccant Air DryerWater SeparatorCoalescing FilterCoalescing FilterCoalescing FilterActivated Carbon FilterPre-FilterSterile FilterDesiccant Air DryerOil-Water Separator

::::::::::::

2. Optical industry

1. Breathing system, surgery system

2. Paint spray, production

3. Transfer system (Antifreeze)

Microorganismn

Wet Air

Dry Air

A/DF

D

Compressor

F

E

G

E

G

I

Oil Mist

Solid Particle 1. Medical, food, beverage industry

Air Dryer

Reference Data

Page 3: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 36 -

Air Dryer

Reference Data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC

Desiccant Performance Table

■ Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

■ Dew point under ATM conversion chart shows dew point -23℃ under ATM at 4℃ under 7kg/cm2G

Dew Point under ATM Conversion Chart

Relative Humidity (%)

Molecular Sieves

Absorption R

ate W (%

)

Silica Gel

Alumina(Spherical)

Alumina(Granular)

Saturated Vapor Volume Table (g/m3)

-50 0.0617 -16 1.48 18 15.4-49 0.0689 -15 1.61 19 16.3-48 0.0767 -14 1.74 20 17.3-47 0.0853 -13 1.88 21 18.3-46 0.0950 -12 2.03 22 19.4-45 0.106 -11 2.19 23 20.6-44 0.117 -10 2.46 24 21.8-43 0.130 -9 2.54 25 23.0-42 0.144 -8 2.74 26 24.4-41 0.159 -7 2.95 27 25.8-40 0.176 -6 3.17 28 27.2-39 0.194 -5 2.41 29 28.7-38 0.214 -4 3.66 30 30.3-37 0.236 -3 3.93 31 32.0-36 0.260 -2 4.22 32 33.8-35 0.286 -1 4.52 33 35.6-34 0.314 0 4.85 34 37.5-33 0.345 1 5.19 35 39.6-32 0.378 2 5.56 36 41.7-31 0.414 3 5.95 37 43.9-30 0.453 4 6.36 38 46.2-29 0.496 5 6.79 39 48.6-28 0.542 6 7.26 40 51.5-27 0.592 7 7.75 41 53.7-26 0.646 8 8.27 42 56.4-25 0.705 9 8.82 43 59.3-24 0.768 10 9.40 44 62.2-23 0.863 11 10.0 45 65.3-22 0.909 12 10.7 46 68.5-21 0.989 13 11.3 47 71.9-20 1.07 14 12.1 48 75.4-19 1.17 15 12.8 49 79.0-18 1.26 16 13.6 50 82.8-17 1.37 17 14.5

Air Dryer

Reference Data

Pres

sure

kgf/c

m2 G

ATM

Dew point under ATM (℃)

Dew

poi

nt u

nder

pre

ssur

e ( ℃

)

Page 4: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com46 -

PNEUMATIC & HYDRAULIC

Functions Description

Warm and humid air enters air to air heat exchanger, not mixed with cold air. The cooled air condenses the saturated air to minimize heat load. The condensate is removed through drain, and the cooled air flows into air to refrigerant heat exchanger again to cool down to 4℃-10℃. The moisture of the compressed air is separated by the impingement separator, and automatically discharged. The cool air is reheated by the warm air flowed in, and flows out through air to air heat exchanger. Reheat increases the volume of air, decreasing relative humidity.

Installation

Please read carefully the following before installing Air Dryer for extended use without breakdown.

1) Appropriate installation place for air dryer● Flat place● Place without acidic or alkaline substances● Place without combustible gas● Place easy for air piping and electric wiring ● Place without dust and vibration● Place easy to check and repair the product● Place with appropriate ambient temperature in winter and summer (1.7℃ - 40℃)

2) Precautions for Installationa) A minimum space of 1.5M or more for the product shall be secured for sufficient fresh air and easy maintenance.b) The strength of the base for installation shall be considered before installation, and foundation work shall be done, if the ground is unstable.

※ Places to Particularly AvoidSlope, place with severe vibration, place exposed to direct sunlight, heated place, place exposed to rains, place with much dust and pollutants, place with bad ventilation, and place with standard service temperature (1.7℃ - 40℃) unavailable.

a) If the temperature falls below 2℃, the inside of drain trap may be frozen.

b) If the temperature rises above 40℃, air dryer may stop working.

Pressure & Temperature Conversion Multiplier Table

Inlet pressure (kgf/cm2) 3 4 5 6 7 8 9 10 11 12 13 14 15

Conversion factor(C1) 0.74 0.84 0.91 0.96 1.00 1.04 1.06 1.09 1.11 1.12 1.14 1.15 1.17

Ambient temperature (℃) 25 30 35 38 40 43 45 50

Conversion factor(C2) 1.16 1.11 1.06 1.00 0.95 0.89 0.84 0.78

Inlet temperature (℃) 30 35 38 40 43 45 50 55 60

Conversion factor(C3) 1.32 1.15 1.00 0.92 0.83 0.78 0.65 0.52 0.39

Processing Capacity Setting Method (FA)FA = Processing Flow x C1 x C2 x C3

Air Dryer

Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)

Page 5: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 56 -

Air Dryer

Reference Data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC

Wiring

a) Electric Wire

The capacity of power cable is as follows.

b) A single-phase circuit breaker for wiring shall be installed for overload protection and to prevent an electric shock due to leakage before installing air dryer.

c) Be sure to install Ground Cord. (Third-class grounding work is required.)

d) Dryer shall be operated within ±5 % of the standard voltage to meet the rated power.

Model KDHR-5-30

KDHR-50

KDHR-75-100 KDHR-500 ~

Rated Power AC 220V / 3PH / 60Hz 220V/380V/440V/3PH/60Hz

Power cable (mm2)

1.25 or more

2.0 or more 5.5 or more

How to Operate

1) Start-up

After installation is completed, start-up shall be provided after thoroughly checking the following.

※ Checkpointsa) Aren’t there any problems in the installed air-pressure pipe and line?b) Is the valve of BY-PASS pipe closed?c) Is the valve of Drain Discharge pipe opened?

※ Checkpoints for Powera) Is voltage normal?b) Isn’t the capacity of fuse circuit breaker for wiring different from the designated.

2) How to Operate

Press the ON button of the power switch.

※ If the power lamp is lighted, operation starts. If the needle on the refrigerant pressure gauge indicates 2.5~3.5kgf/cm2

(R-134c)~3.5~5.5kgf/cm2(R-22) in one minute after the refrigeration compressor has started to operate, it means a normal state.※ In 5 minutes after operation, compressed air flows in slowly while the air compressor is in operation. (Be careful that pressure is not loaded on air dryer at once.)

※ NoteTo restart after stop, an interval of 5 minutes or more is required.

Daily Opertion Method

1) Press the operation switch.2) The RUN lamp is lighted, and the refrigeration compressor is operated.3) Check if the needle on the refrigerant pressure gauge indicates 4~4.5kgf/cm2

4) Allow compressor air to flow in 5 minutes after operation.

Safety Device

For safe use, it has a safety device mounted. If the safety device functions,Air dryer stops automatically.1) Electric Circuit: Motor Protector If over current flows in Refrigeration Compressor, motor protector works to stop air dryer.2) How to Release a) Remove the cause of stop (see Causes of Failure and Measures.) b) Press the START button for operation.

Tips for Hot Gas Bypass Valve Adjustment

1) Since the hot gas bypass valve has been adjusted when shipped, it shall be adjusted only if abnormalities are found. Loosen the nut of the valve, and adjust the valve with a driver, seeing the refrigerant pressure gauge, until the needle on the refrigerant pressure gauge is within the normal scope.

Pressure Scope of Refrigerant R-22- Low Pressure : 0.4~0.45MPa(4~ 4.5kgf/cm2)- High Pressure : 1.3~1.75MPa(13 ~ 20kgf/cm2)

Air Dryer

Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)

Piping

The assembly of pipes shall be adjusted, using tools such as a wrench, and piping shall be provided for sections with defective screws to prevent air leakage. If not fixed, the case may be damaged.a) The inlet and outlet of air dryer shall be correctly connected in piping.b) Be careful that the weight of piping is not loaded on the body.c) Make sure that the vibration of air compressor is not transmitted to dryer, and avoid vertical piping.d) Install a by-pass pipe between inlet and outlet of air dryer.e) For convenience purpose, union or fl ange shall be applied to the inlet and outlet of dryer for connection.f) Zinc-plated pipe shall be used.g) The condensed water from the drain outlet shall be discharged to the outside through a separate drainpipe. Note: ※ Be sure to close by-pass valve while in use.※ Since if the drainpipe is vertical or extended, pressure is produced in the pipe, the condensed water may not be discharged.

Page 6: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com66 -

PNEUMATIC & HYDRAULIC

Daily Check & Cleaning

1) Daily Checks a) Check the Auto Drain Trap. b) Check if the timer of Electronic Trap has been correctly set (ON 2 seconds, OFF 2 minutes). c) Check if there are any air leaks. d) Check if it works normally. (Check if water comes out.) e) Check inlet temperature for compressed air and ambient temperature, and clean Condenser and After cooler for the removal of dust on a regular basis.2) Cleaning a) Cleaning of Condenser • Clean the condenser on a regular basis, using a vacuum cleaner, a brush, or an air gun. • Dryer cases shall have both sides disassembled one by one. • If dust is accumulated on the condenser, it is not only good for heat exchange, but also may stop the operation of air dryer as safety device works, if severe.

※ Note Be careful not to deform the fins of Condenser while cleaning. b) Cleaning of Auto Drain Trap (Solenoid Valve) • Disassemble and clean the auto drain trap on a regular basis for a regular operation all the time.

Causes of Failure & Measures If failure is suspected while using, please check the following.

Causes

Symptoms

Refrigerant leaks

Thermal R

elay is defective

Bypass Valve is opened

Light from Lam

p is blocked

Sw

itch is defective

Pow

er voltage is too low

Refrigeration C

ompressor is

defective

Solenoid Valve is defective

Solenoid Valve has foreign

substance

Solenoid Valve has been

frozen

Air processing volum

e is too m

uch

Cooling capacity has

decreased

Hot G

as Bypass Valve is

defective

Condenser is clogged

The ambient tem

perature is too high

Fan Motor is defective

Com

presser Magnet is

defective

Pressure S

witch for fan control

is defective

Even though the switch is turned ON, it does not operate.

Operation Lamp is OFF ● ● ● ● ●

Operation Lamp is ON ● ●Water and oil come out while the needle on the refrigerant pressure gauge indicates normal. ● ● ● ● ●

he needle on the refrigerant pressure gauge indicates high pressure, and water and oil come out. ● ● ● ● ● ● ● ● ● ●

Condensed water is not discharged from the Auto Drain. ● ● ●

The temperature of Air Outlet is equal to or higher than that of Air Inlet. ● ● ● ● ●

The machine has stopped during operation. ● ● ● ● ● ● ● ● ●

High Pressure Alarm Lamp is lighted. ● ● ● ● ● ●

Over Current Alarm Lamp is lighted. ● ● ● ●

Measures

Check gas leak areas

Exchange

Close the B

ypass Valve

Exchange

Exchange

Use R

egulated Voltage

Exchange

Exchange

Disassem

ble and Clean

Set the am

bient temperature to m

ore than 2℃

Air processing volum

e shall be set at the normal

Check gas leakage and refrigerant am

ount

Exchange and A

djust

Clean

Lower the am

bient temperature

Exchange

Exchange

Exchange

Air Dryer

Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)

Page 7: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 76 -

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)

KDHR - 5

① ②

① SeriesKDHR Air cooled type refreigerated air dryer

② Size5, 7, 10, 15, 20, 30, 50, 75, 100,

150, 200, 250, 300, 400, 500, 600, 800

How to Order

KDHR series

Specifi cations

ModelFlow Capacity(Nm3/min) Connection

Rc(PT) Freon GasElectrical Power Dimensions (mm)

Weight (kg)60Hz 50Hz V A KW Width Length Height

KDHR-5 0.62 0.57 3/4" (S)

R-134a

AC1Ph

220V60Hz

1.14 0.2 310 575 535 40

KDHR-7 0.97 0.89 3/4" (S) 1.14 0.2 310 575 535 40

KDHR-10 1.35 1.23 3/4" (S) 2.5 0.4 310 575 535 40

KDHR-15 1.96 1.8 3/4" (S) 3.5 0.8 310 670 560 45

KDHR-20 2.6 2.4 1" (S)

R22

6.1 0.9 320 700 670 84

KDHR-30 3.9 3.5 1" (S) 5.1 0.9 320 700 670 86

KDHR-50 7.2 6.6 2" (S) 6 1.0 411 1,020 940 117

KDHR-75 11.1 10.5 2" (S) 10 1.9 411 1,020 940 170

KDHR-100 14.6 13.3 2" (S) 12.5 2.8 411 1,030 1,030 196

KDHR-150 21.9 20.0 3" (F)

AC3Ph

220V/380V/440V60Hz

12.2 3.8 700 1,100 1,600 325

KDHR-200 31.3 28.6 3" (F) 17.0 5.2 700 1,100 1,600 380

KDHR-250 40.1 36.6 4" (F) 17.0 5.2 900 1,700 1,800 468

KDHR-300 47.6 43.5 4" (F) 17.0 5.2 900 1,700 1,800 660

KDHR-400 59.5 54.3 4" (F) 26.5 5.6 1,000 2,000 1,800 790

KDHR-500 73.9 67.5 6" (F) 16 12.2 2,500 1,250 2,500 1,560

KDHR-600 89.6 81.8 6" (F) 17 12.2 2,500 1,250 2,500 1,700

KDHR-800 112.5 102.7 8" (F) 21 13.8 2,500 1,250 2,500 1,780

※ In/Out Connection : (S) Screw, (F) Flange

Dew Point Operating Pressure Fluid Inlet Temperature Ambient Temperature Condenser

1.7℃~4℃7.0kg/cm2(0.7MPa)

Max:9.9kg/cm2(0.99MPa) Compressed Air 40℃ 1.7℃~40℃ Air Cooled

※ Coefficient of air flow capacity: inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating dew point 4℃

Features

● Specially designed heat exchanger eliminated minute moisture in the

high temperature and high humidity compressed air through rapid

cooling cycle.● Easy disassembling case serve for easy A/S and maintenance.

Page 8: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com86 -

PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)

Dimensions (KDHR 05~15)

Unit:mm

Model A B C D E F G H I J K L N M O P Q S

KDHR5~10 6A 665 50 100 22 325 410 510 50 100 310 50 85 75 10 37 66 68

KDHR15 6A 700 50 100 22 360 410 510 50 100 310 85 85 75 10 37 66 68

Dimensions (KDHR 20~30)

Page 9: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 96 -

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)

Dimensions (KDHR 50~100)

Unit:mm

Model A B C D E F G H I K L N M O P Q S T W X Y

KDHR 50 940 60 180 420 180 60 60 20 37 66 68 15 490 15 640 60 700 60 140 820 1 1/2"(40A)

KDHR 75 1,090 60 180 570 180 60 50 20 37 66 68 15 570 15 930 70 830 70 175 970 2"(50A)

KDHR 100 1,190 60 180 670 180 60 50 30 37 66 68 15 570 15 990 80 910 80 175 1,070 2"(50A)

Dimensions (KDHR 150~400)

Unit:mm

Model A B C D E F G H I J K L N M O P Q S T W Y X

KDHR150~250 800 200 250 200 250 80 20 125 100 330 1,700 1,800 300 15 900 15 350 300 350 350 1,700 350

KDHR300~400 1,000 200 300 200 300 80 20 125 100 330 1,700 1,800 300 25 1,000 25 350 300 350 400 2,000 400

Page 10: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com106 -

PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)

Dimensions (KDHR 500~800)

Unit:mm

Model A B C D E F G H I J K L N M O P Q S T W Y X Z ZZ

KDHR 500 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 5" 1,122 1,200 1,272 6"

KDHR 600 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 5" 1,122 1,200 1,272 6"

KDHR 800 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 6" 1,122 1,200 1,272 8"

Page 11: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 116 -

Air Dryer

Reference Data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDHR-W seriesRefrigerated Air Dryer (Water Cooled Type)

KDHR - 400 W

① ② ③

① SeriesKDHR Refrigerated air dryer

② Size400, 500, 600, 750, 900, 1,200, 1,500,

2,000, 3,000, 4,000, 5,000, 6,000

How to Order

KDHR-W series

Specifi cations

ModelFlow Capacity (Nm3/min) In/Out Connection

(Air)Rc(PT)

In/Out Connection (Water)Rc(PT)

Cooling Water(ℓ/min)

Refrigeration Compressor

(HP)Weight

(Kg)60Hz 50Hz

KDHR-400W 63.6 58.1 4"(F) 1 1/2"(S) 53/105 7 1/2 640

KDHR-500W 79.1 72.2 6"(F) 2"(S) 64/127 10 1,490

KDHR-600W 95.8 87.5 6"(F) 2"(S) 80/159 10 1,570

KDHR-750W 120.3 109.8 8"(F) 2"(S) 105/210 15 1,620

KDHR-900W 155.3 141.8 8"(F) 2 1/2"(F) 158/315 20 1,740

KDHR-1200W 177.6 162.1 8"(F) 2 1/2"(F) 183/365 20 1,890

KDHR-1500W 221.9 202.6 10"(F) 2 1/2"(F) 210/420 30 1,970

KDHR-2000W 295.8 270.1 12"(F) 3"(F) 265/530 40 2,180

KDHR-3000W 473.3 432.1 14"(F) 3"(F) 424/848 60 2,320

KDHR-4000W 591.7 540.2 16"(F) 4"(F) 530/1,060 80 2,540

KDHR-5000W 709.9 648.1 18"(F) 5"(F) 636/1,272 100 2,760

KDHR-6000W 887.4 810.1 20"(F) 5"(F) 795/1,590 130 3,110

※ In/Out Connection : (S) Screw, (F) Flange

Refrigerant Dew Point Max Operating Pressure Fluid Inlet Temperature Ambient

Temperature Condenser Electrical Power

R22 1.7℃~4℃9.9kg/cm2

(0.95MPa) Compressed Air 45℃ 1.7℃~45℃ Water Cooled AC 3Ph 220V/380V/440V 60Hz

※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, cooling water inlet temperature 17℃~30℃, cooling pressure range 2kgf/cm2(0.2MPa) ~ 4.5kgf/cm2(0.45MPa), operating dew point 4℃

③ Cooling TypeW Water Cooled

Features

● Refrigerant is condesed by water cooled-condenser when going through

refrigeration cycle, it produces stable refrigeration cycle.

Page 12: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com126 -

PNEUMATIC & HYDRAULIC KDHT seriesRefrigerated Air Dryer (High Temperature Type)

KDHT - 5

① ②

① SeriesKDHT High temperature type refrigerated air dryer

② Size5, 7, 10, 15, 20, 30, 50

How to Order

KDHT series

Specifi cations

ModelFlow Capacity (Nm3/min) In/Out

ConnectionRc(PT)

Freon GasDimensions (mm)

Weight (kg)60Hz 50Hz Width Length Height

KDHT-5 0.62 0.57 3/4"

R-134a

320 600 860 52

KDHT-7 0.97 0.89 3/4" 320 600 860 54

KDHT-10 1.35 1.23 3/4" 320 600 860 56

KDHT-15 1.96 1.8 3/4" 320 600 860 67

KDHT-20 2.63 2.4 1"

R22

400 800 1,060 93

KDHT-30 3.85 3.5 1" 400 800 1,060 98

KDHT-50 7.24 6.6 1" 700 1,100 1,250 130

Features

● A combination type air dryer with built-in after cooler make it easy to be

installed at narrow space. Standard specifi cations include main line fi lter.

Dew Point Operating Pressure Fluid Inlet Temperature Electrical Power

4℃7.0kg/cm2(0.7MPa)

Max:9.9kg/cm2(0.99MPa)

Compressed Air 55℃Max:80℃

1Ph 220V 60Hz

※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating dew point 4℃

Page 13: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 136 -

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDAH seriesDesiccant Air Dryer (Heatless Type)

KDAH - 5

① ②

① SeriesKDAH Desiccant Air Dryer

② Size5, 7, 10, 20, 30, 40, 50, 75, 100, 130,

150, 170, 200, 250, 300, 400, 450, 500, 600, 750, 900

How to Order

KDAH series

Specifi cations

Model Flow Capacity (Nm3/hr)

In/Out ConnectionRc(PT)

Gel/2 Tower (kg)

Dimensions (mm)Weight (kg)

Width Length Height

KDAH-5 28 1/2"(S) 10 700 500 1,050 70

KDAH-7 55 1/2"(S) 22 750 550 1,300 115

KDAH-10 91 3/4"(S) 30 750 550 1,600 158

KDAH-20 173 1"(S) 62 850 700 1,900 225

KDAH-30 247 1"(S) 90 950 750 1,800 275

KDAH-40 356 1 1/2"(S) 100 1,000 750 1,900 320

KDAH-50 526 1 1/2"(S) 136 1,050 900 1,950 380

KDAH-75 651 1 1/2"(S) 176 1,100 900 2,450 490

KDAH-100 838 2"(S) 222 1,250 1,000 2,550 590

KDAH-130 975 2"(S) 258 1,250 1,000 2,350 615

KDAH-150 1,247 2"(S) 283 1,300 1,000 2,500 675

KDAH-170 1,511 2 1/2"(F) 392 1,350 1,050 2,650 845

KDAH-200 1,778 2 1/2"(F) 490 1,450 1,100 2,750 985

KDAH-250 2,160 3"(F) 546 1,550 1,200 2,550 1,145

KDAH-300 2,576 3"(F) 656 1,650 1,300 2,550 1,225

KDAH-400 3,089 3"(F) 910 1,850 1,400 2,650 1,570

KDAH-450 3,557 4"(F) 1,276 2,100 1,550 2,850 2,190

KDAH-500 4,058 4"(F) 1,430 2,100 1,600 2,890 2,400

KDAH-600 5,796 6"(F) 2,032 2,400 1,850 3,080 3,220

KDAH-750 7,371 6"(F) 2,380 2,600 2,150 3,100 4,560

KDAH-900 8,946 6"(F) 3,088 3,000 2,150 3,100 5,600

※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating pressure 7kgf/cm2, dew point -40℃

Features

● KDAH series are designed for reliable dew point -40℃(Atm).● Suitable for 4 seasons and parts are easy to repair.

Page 14: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com146 -

PNEUMATIC & HYDRAULIC KDAE seriesDesiccant Air Dryer (Heater Type)

KDAE - 20

① ②

① SeriesKDAE Desiccant air dryer with heater

② Size20, 40, 50, 75, 100, 130, 150, 200, 250, 280, 300, 400, 500, 600,

750, 900, 1,200, 1,500, 2,000

How to Order

KDAE series

Specifi cations

Model Flow Capacity(Nm3/hr)

In/Out Connection

Rc(PT)Gel/Tower

(kg)Heater

(kw)Dimensions (mm)

Weight (kg)Width Length Height

KDAE-20 158 1"(S) 74 2 1,250 900 1,700 340

KDAE-40 391 1 1/2"(S) 136 3 1,450 1,000 1,950 540

KDAE-50 523 1 1/2"(S) 174 4.5 1,450 1,100 2,380 745

KDAE-75 627 1 1/2"(S) 223 5.5 1,550 1,100 2,450 905

KDAE-100 914 2"(S) 300 7.5 1,550 1,150 2,450 1,130

KDAE-130 998 2"(S) 394 9.5 1,750 1,150 2,600 1,380

KDAE-150 1311 2 1/2"(F) 490 12 1,850 1,500 2,600 1,620

KDAE-200 1,764 2 1/2"(F) 558 15 1,900 1,500 2,800 1,850

KDAE-250 2,048 3"(F) 750 18.5 1,950 1,500 2,800 2,060

KDAE-280 2,394 3"(F) 882 20 2,000 1,600 2,800 2,440

KDAE-300 2,804 3"(F) 1,052 25 2,200 1,600 2,650 2,990

KDAE-400 3,517 4"(F) 1,430 32 2,400 1,800 2,950 3,930

KDAE-500 4,486 4"(F) 1,688 40 2,550 1,900 2,900 4,500

KDAE-600 5,130 6"(F) 2,448 60 3,000 2,150 3,200 5,960

KDAE-750 6,930 6"(F) 2,864 70 3,300 2,150 3,100 6,750

KDAE-900 9,006 6"(F) 3,100 100 3,700 2,750 3,650 10,630

KDAE-1,200 11,028 8"(F) 4,590 110 4,200 3,000 3,150 11,200

KDAE-1,500 12,600 9"(F) 5,264 125 4,200 3,350 3,900 12,800

KDAE-2,000 15,750 10"(F) 6,580 160 4,600 3,200 3,300 16,700

※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet temperature 38℃, ambient temperature 38℃, operating pressure 7kgf/cm2, dew point -50℃

Features

● KDAE Series are designed for reliable dew point under -70℃(Atm) with

minimizing overheating of heater. 2 way butterfly valve is installed in all

products. Dehumidification time can be extended regarding to load.

● Option

Dew Point Control:Dehumidification time can be extended regarding to

load.

Page 15: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 156 -

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDAE-SDesiccant Air Dryer (Heater, Skid Type)

KDAE - 20 S

① ② ③

① SeriesKDAE Deciccant air dryer with heater

③ TypeS Skid

② Size50, 75, 100, 130, 150, 200, 250, 300, 400, 500, 600, 750, 1550,

3000, 4100

How to Order

KDAE-S series

Specifi cations

Model Flow Capacity(Nm3/hr)

In/Out Connection

Rc(PT)Gel/ Tower

(kg)Heater

(kw)Dimensions (mm)

Weight (kg)Width Length Height

KDAE-50S 523 1 1/2'' 174 4.5 1,450 1,500 2,380 890

KDAE-75S 627 1 1/2'' 223 5.5 1,550 1,500 2,450 985

KDAE-100S 914 2'' 300 7.5 1,750 1,700 2,450 1,320

KDAE-130S 998 2'' 394 9.5 1,750 1,700 2,600 1,550

KDAE-150S 1,311 2 1/2'' 490 12 1,850 1,800 2,600 1,820

KDAE-200S 1,764 2 1/2'' 558 15 1,900 1,850 2,800 2,100

KDAE-250S 2,048 3'' 750 18.5 2,800 1,600 2,800 2,320

KDAE-300S 2,804 3'' 1,052 25 2,800 1,600 2,650 3,200

KDAE-400S 3,517 4'' 1,430 32 3,200 2,500 2,950 5,050

KDAE-500S 4,486 4'' 1,688 40 3,300 2,550 2,900 5,100

KDAE-600S 5,130 6'' 2,448 60 3,400 2,500 3,200 7,300

KDAE-750S 6,930 6'' 2,864 70 3,600 2,800 3,900 9,500

KDAE-1550S 2,952 4'' 1,388 32 3,200 1,700 2,880 4,900

KDAE-3000S 5,400 6'' 2,376 60 3,600 2,500 3,165 7,200

KDAE-4100S 6,600 6'' 2,864 70 3,600 2,800 3,900 9,500

Features

● KDAE-S series are designed for reliable dew point -40℃(Atm) with

minimizing overheating of heater. Pre fi lter and after fi lter is designed in

skid type, easier piping work.

Page 16: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com166 -

PNEUMATIC & HYDRAULIC KDAO seriesDesiccant Air Dryer (Oiless Type)

KDAO - 5

① ②

① SeriesKDAO Desiccant air dryer

② Size5, 7, 10, 20, 30, 40, 50, 75, 100, 130,

150, 170, 200, 250, 300, 400, 450, 500, 600, 750, 900

How to Order

KDAO series

Specifi cations

Model Flow Capacity(Nm3/hr)

In/Out Connection

Rc(PT)SOMA

(kg)Gel/2 Tower

(kg)Dimensions (mm)

Weight (kg)Width Length Height

KDAO-5 28 1/2''(S) 3 10 1,000 500 1,050 80

KDAO-7 55 1/2''(S) 6 22 1,000 550 1,300 175

KDAO-10 91 3/4''(S) 9 30 1,150 550 1,600 221

KDAO-20 173 1''(S) 18 62 1,100 700 1,900 300

KDAO-30 247 1''(S) 26 90 1,250 750 1,800 365

KDAO-40 356 1 1/2''(S) 29 100 1,600 750 1,900 442

KDAO-50 526 1 1/2''(S) 40 136 1,550 900 1,950 510

KDAO-75 651 1 1/2''(S) 55 176 1,600 900 2,450 700

KDAO-100 838 2''(S) 69 222 1,750 1,000 2,550 850

KDAO-130 975 2''(S) 80 258 1,850 1,000 2,350 895

KDAO-150 1,247 2''(S) 88 283 1,900 1,000 2,500 1,000

KDAO-170 1,511 2 1/2''(F) 121 392 2,000 1,050 2,650 1,260

KDAO-200 1,778 2 1/2''(F) 151 490 2,100 1,100 2,750 1,455

KDAO-250 2,160 3''(F) 172 546 2,100 1,200 2,550 1,505

KDAO-300 2,576 3''(F) 206 656 2,400 1,300 2,550 1,745

KDAO-400 3,089 3''(F) 287 910 2,600 1,400 2,750 2,380

KDAO-450 3,557 4''(F) 402 1,276 3,000 1,550 2,750 3,190

KDAO-500 4,058 4''(F) 451 1,430 3,000 1,600 2,900 3,500

KDAO-600 5,796 6''(F) 660 2,032 3,500 1,850 3,080 4,790

KDAO-750 7,371 6''(F) 773 2,380 3,900 2,150 3,100 5,670

KDAO-900 8,946 6''(F) 1,003 3,088 4,200 2,150 3,100 6,890

※ In/Out Connection : (S) Screw, (F) Flange

Features

● KDAO series is specially designed to eliminate oil mist. Heatless type or

heater type can be custom made depending on the dew point limit.

Page 17: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 176 -

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDAB seriesDesiccant Air Dryer (Heater Blower Type)

KDAB - 110

① ②

① SeriesKDAB Desiccant air dryer

② Size110, 130, 150, 200, 250, 280, 300, 400,

500, 600, 750, 1,200, 1,500, 2,000

How to Order

KDAB series

Specifi cations

Model Flow Capacity(Nm3/hr)

In/Out Connection

Rc(PT)

Electrical Power Gel/2 Tower (kg)

Dimensions (mm)Weight (kg)

Heater (kw) Blower (Hp) Width Length Height

KDAB-110 873 2'' 13 3 400 2,700 1,400 2,350 1,080

KDAB-130 970 2 1/2'' 13 3 480 2,700 1,400 2,400 1,320

KDAB-150 1,260 2 1/2'' 17 3 610 3,000 1,450 2,400 1,520

KDAB-200 1,520 3'' 20 5 730 3,300 1,500 2,400 1,770

KDAB-250 1,845 3'' 25 5 900 3,500 1,600 2,430 2,060

KDAB-280 2,180 3'' 32 5 1,080 3,550 1,700 2,470 2,450

KDAB-300 3,010 4'' 40 7.5 1,440 3,750 1,900 2,550 3,240

KDAB-400 3,490 4'' 46 7.5 1,700 3,850 2,000 2,550 3,720

KDAB-500 4,365 6'' 55 10 2,100 4,500 2,200 2,960 4,410

KDAB-600 5,820 6'' 80 10 2,800 4,800 2,200 3,000 5,390

KDAB-750 7,760 6'' 100 15 3,720 5,000 2,200 3,000 6,860

KDAB-1,200 9,800 8'' 130 20 4,600 6,200 2,400 3,100 11,270

KDAB-1,500 11,650 8'' 150 20 5,600 6,200 2,400 3,100 12,250

KDAB-2,000 15,550 10'' 180 25 6,970 7,500 2,500 3,300 13,900

Features

● KDAB is an energy saving product which minimized usage of compressed

air, and blower is used to inhale air for desiccant regeration. ● Dehumidifi cation time can be extended regarding to load.

Cycle Time■ Total Cycle : 8hr (Two Tower)■ Drying Cycle : 4hr (Per Tower)■ Regenaration Cycle : 4hr (Per Tower) - Heating : Using external air - Cooling : Using internal air

Page 18: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com186 -

PNEUMATIC & HYDRAULIC

Desiccant Air Dryer (Non-Purge Type)

KDNP series

KDNP - 1100

① ②

① SeriesKDNP Desiccant air dryer (Non-purge type)

② Size1,100, 1,550, 2,100, 3,000, 4,100, 5,400,

6,000, 7,000, 9,000

How to Order

KDNP series

Specifi cations

Model Flow Capacity(Nm3/hr)

In/Out Connection(Flange)

Gel/2 Tower (kg)

Dimensions (mm)Weight (kg)

Width Length Height

KDNP-1100 1,950 3''(F) 858 2,600 1,750 2,500 2,500

KDNP-1550 2,952 4''(F) 1,388 2,800 1,900 2,800 3,000

KDNP-2100 3,702 5''(F) 1,640 3,200 2,200 2,900 4,100

KDNP-3000 5,400 6''(F) 2,376 4,000 2,400 3,000 5,500

KDNP-4100 6,600 6''(F) 2,510 4,550 2,400 3,100 7,500

KDNP-5400 9,498 8''(F) 3,100 5,200 3,000 3,300 10,800

KDNP-6000 10,500 8''(F) 4,590 5,600 3,100 3,500 12,500

KDNP-7000 12,000 8''(F) 5,264 5,800 3,100 3,500 13,800

KDNP-9000 15,000 10''(F) 6,580 6,500 3,500 3,610 17,100

Features

● KDNP Series regenerate desiccant using waste heat from compressor

(approx. 150℃). This energy saving air dryer have no compressed air

loss in flowing partial compressed air into dryer inlet after desiccant

regeneration● Dehumidifi cation time can be extended regarding to load.

Cycle time■ Total Cycle : 8hours (Two Tower)■ Drying Cycle : 4hours (Per Tower)■ Regenaration Cycle : 4hours (Per Tower) - Heating : Air compressor compress waste heat circulation - Cooling : Partial compressed air circulation

Page 19: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 196 -

PNEUMATIC & HYDRAULIC

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

KDH-C seriesAfter Cooler

KDH - 1C

① ②

① SeriesKDH After cooler

② Size1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C, 10C, 11C, 12C

How to Order

KDH-C series

Specifi cations

Model

Flow Capacity(Nm3/hr)

In/Out Connection

Rc(PT)

Max. pressure(kg/cm2)

Inlet Temp(℃)

Ambient Temp(℃)

Fan(Ø)

Fan Motor(W)

PowerDimensions (mm) Weight

(kg)60Hz 50Hz Width Length Height

KDH-1C 2.2 2.0 3/4"(S)

9.9 80℃↓ 38℃↓

250 16 AC 1Ph 220V60Hz 490 270 545 23

KDH-2C 3.3 3.0 1"(S) 300 66 AC 1Ph 220V 60Hz AC 3Ph 380V/440V

option

578 300 582 25

KDH-3C 5.2 4.7 1 1/2"(S) 350 100 738 300 692 35

KDH-4C 8.0 7.3 2" 350 100×2

AC 3Ph 220V/380V60Hz

1,070 350 765 69

KDH-5C 13.5 12.3 2 1/2"(F) 350X2 200×2 1,210 450 970 83

KDH-6C 17.5 15.9 3"(F) 400X2 0.2×2 1,385 460 990 100

KDH-7C 30 27.4 4"(F) 500X2 0.4×2 1,630 600 1,100 159

KDH-8C 41 37.4 4"(F) 550X2 0.4×2 1,850 600 1,220 180

KDH-9C 52 47.5 5"(F) 650X2 0.75×2 2,080 710 1,300 240

KDH-10C 80 73 5"(F) 500X4 0.4×2 2,200 650 1,850 280

KDH-11C 125 114 6"(F) 600X4 0.4×2 2,510 650 2,110 350

KDH-12C 155 142 8"(F) 650X4 0.75×2 2,610 750 2,110 420

※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet temperature 38℃, ambient temperature 30~45℃, outlet temperature 30℃(△P 8℃), operating pressure 7kgf/cm2.

Features

● After cooler is an essential refrigeration supporting equipment which

is installed before air dryer to cool hot and high humidity air, support air

dryer to operate more effi ciency without malfunction.● Easy installment and maintenance without cooling water.● Low noise

Page 20: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com206 -

PNEUMATIC & HYDRAULIC KDRC seriesChiller

KDRC - 1A

① ②

① SeriesKDRC Chiller

② Size1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 30A, 40A

How to Order

KDRC series

Specifi cations

Features

● Built-in high efficient and low noise compressor provide excellent

refrigeration. Accurate temperature control and wide range temperature

control is available by its digital temperature control devise.

ModelCooling Capacity(Kcal/hr)

Temp Range

(℃)

Ambient Temp (℃)

Cooling Water Pressure Range

kg/cm2(MPa)

Cooling Water Circulation

Volume Range(LPM)

Cooling Water Tank Capacity

(Liter)

Cooling Water Flow Rate

(LPM)Refrigerant

Compressor Capacity

(kw)

Circulation Pump

Capacity(kw)

KDRC-1A 2,800

5~30(±2℃) 0~45

1.0~2.5(0.1~0.25) 5~20 20 15

FreonR-22

0.75 0.35

KDRC-2A 5,600 1.5~3.5(0.15~0.35) 15~80 40 20 1.5 0.75

KDRC-3A 8,400 1.5~3.5(0.15~0.35) 15~80 60 20 2.25 0.75

KDRC-5A 14,000 3.0~6.0(0.3~0.6) 15~80 80 25 3.75 1.1

KDRC-7.5A 21,000 1.0~2.5(0.1~0.25) 30~130 100 25 5.63 1.1

KDRC-10A 28,000 1.5~3.5(0.15~0.35) 30~130 135 25 7.5 1.1

KDRC-15A 42,000 2.5~4.0(0.25~0.4) 100~210 165 32 11.25 2.2

KDRC-20A 56,000 3.0~5.0(0.3~0.5) 100~210 280 40 15 3

KDRC-30A 84,000 2.0~3.5(0.2~0.35) 160~430 350 50 22.5 4

KDRC-40A 112,000 3.5~5.5(0.35~0.55) 160~430 500 65 30 5.5

ModelCooling

Fan Motor Capacity (kw)

Power Consumption

(kw)Power Control circuit

powerDimensions (mm)

Width Length Height

KDRC-1A 0.1 1.2 AC 220V 1Ø 50/60Hz

AC 220V1Ø

470 760 870

KDRC-2A 0.2 2.45

AC 220V/380V/440V 3Ø 50/60Hz

580 960 1,050

KDRC-3A 0.2 3.2 580 960 1,050

KDRC-5A 0.4 5.25 660 1,060 1,130

KDRC-7.5A 0.75 7.48 760 1,100 1,345

KDRC-10A 0.4X2 9.4 760 1,600 1,350

KDRC-15A 0.4X2 14.95 945 1,750 1,595

KDRC-20A 0.75X2 19.5 1,050 2,100 1,768

KDRC-30A 0.75X3 28.75 1,050 2,900 1,921

KDRC-40A 0.75X3 37.75 1,200 3,800 2,140

※ Specifications might be change without notice. ※ Motor and other parts might be different depeding on production specifications.※ Cooling efficiency : Temperature control range 5~30℃, Ambiet temperature 0~45℃, operating pressure 7kgf/cm2(0.7MPa), operating dew point -50℃

Page 21: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 216 -

PNEUMATIC & HYDRAULIC

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

SEPREMIUM seriesOil-Water Separator

SEPREMIUM 10

① ②

① SeriesSEPRMIUM Oil-water separator

② Capacity10, 20, 30

How to Order

SEPREMIUM series

Specifi cations

Model Capacity(Nm3/min)

In/Out Connection Dimensions (mm)

In Out Width Length Height

SEPREMIUM 10 10 1/2" 1" 650 240 750

SEPREMIUM 20 20 1/2" 1" 780 305 900

SEPREMIUM 30 30 1/2" 1" 970 380 900

Features

● Oil-water separator is designed to eliminated oil after oil and

water is being separated effi ciently.● Easy installment, easy maintenance● Condensed water discharged by intelegent drain

Indicator In/Out Connection

Page 22: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com226 -

PNEUMATIC & HYDRAULIC

Features

● Service tank is assential at the outlet of compressor for provide

air in uniform pressure without pulsation.● Capacity of tank is determined by the usage of compressor

such as capacity, working pressure and etc.● Tank is corresponding with occupation safety and health acts,

user shall use the product after inspection by occupation safety

and heatlh admisistration.● The whole tank's design and performance is after inspection of

occupation safety and heatlh admisistration.

KDRT seriesReceiver Tank

KDRT - 500-A

① ②

① SeriesKDRT Receiver tank

② Size500-A, 800-A, 1,000-A, 1,500-A, 2,000-A, 3,000-A,

5,000-A, 8,000-A, 10K, 20K, 30K, 56K

How to Order

KDRT series

Specifi cations

How to Select Receiver Tank

Dimensions

ModelFlow

Capacity (m3)

In/Out Connection

Dimensions (mm) Weight (kg)D H

KDRT-500-A 0.5 PT 50A 660 1,733 184

KDRT-800-A 0.8 PT 50A 760 2,088 306

KDRT-1,000-A 1.0 PT 50A 850 2,132 392

KDRT-1,500-A 1.5 PT 50A 946 2,486 521

KDRT-2,000-A 2.0 FL 80A 1,110 2,567 764

KDRT-3,000-A 3.0 FL 80A 1,310 2,666 993

KDRT-5,000-A 5.0 FL 100A 1,485 3,361 1,628

KDRT-8,000-A 8.0 FL 125A 1,845 3,539 2,528

KDRT-10K 10.0 FL 150A 2,025 3,648 3,020

KDRT-20K 20.0 FL 200A 2,400 5,200 5,500

KDRT-30K 30.0 FL 250A 2,800 5,950 6,500

KDRT-56K 56.0 FL 350A 2,620 11,232 19,000

DDH

■ Air receiver tank capacity formula

V Volume of the receiver tank (m3)t Time allowed for pressure drop to occur (min)

Q1 Air demand by compressor (m3)Q2 Surplus air volume from compressor (m3)P1 Free air pressure (kgf/cm2)P2 Receiver tank proof pressure (kgf/cm2)P3 Compressor working pressure (kgf/cm2)

V = {P1×(Q1-Q2)×t} / (P2-P3)

■ Air discharge by compressor is 550 ℓ/min and the pressure of discharged air is 8.5kgf/cm2,what is the size of receiver should be selected if the compressor eject 1500ℓ air in 40 seconds?

P1 1.03323 kgf/cm2 P2 9.53323kgf/cm2(a)Q1 1.5m3 P3 6.03323kgf/cm2(a)Q2 0.55m3×40sec/60sec≒0.37m3 t 0.67min(40sec)

V = {1.0332×(1.5-0.37)×0.67} / (9.5332-6.0332)

= 0.223(m3)≒230ℓ= 0.23m3

Install a receiver tank which the volume is greater than 0.23m3

� Operating pressure: 9.9kgf/cm2 (Custom made of other specification is available upon customer request)

Page 23: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 236 -

PNEUMATIC & HYDRAULIC

Air Dryer

ReferenceData

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

KDHAD seriesAuto Drain Trap

KDHAD - 125

① ②

① SeriesKDHAD Auto drain trap

② In/Out Connection125 Rc(PT) 1/2300 M30

How to Order

KDHAD series

Specifi cations Dimensions

Model KDHAD-125 KDHAD-300

In/Out Connection Rc(PT)1/2 M30

Operation Pressure 1.5~9.9kgf/cm2 (0.15~0.99MPa)

Max. Pressure 13kgf/cm2 (1.3MPa)

Inlet Temp ℃ 60℃

Application Filter (20A~150A), Tank

KDHAD-125KDHAD-300

Applications

● Automatic discharge condensate water in the

compressed air of air compressor, receiver tank,

water cooler, air dryer and etc.

163

93

Ø6

Inlet port

Page 24: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com246 -

PNEUMATIC & HYDRAULIC

EZ-1 series

Timer Valve

Operating interval 0.5-45 min, Adjustable Operation 2/2 Way, direct acting

Valve open/close time 0.5-10 sec, Adjustable In/Out port 1/2'' BSP

Manual switch Micro switch Operating pressure 0~16.0kgf/cm2(0~1.6MPa)

Voltage 230 VAC/DC, 50/60Hz (±10%) Ambient Temperature 2℃ ~ 55℃

Current consumption Max. 7mA Seal material FPM (Viton)

Operation temperature -40℃ ~ 60℃ Fluid temperature Max. 90˚ C

Protect class IP 65 Valve material Brass

Material ABS plastic FR grade UL94Vo Insulation class Grade F

Connection DIN 43650A ISO 440/6952 Protect class IP 65

Display lamp1 LED (Yellow) Display ON Orifi ce 4.0 mm

1 LED (Yellow) Display OFF Voltage 230VAC 50/60 Hz (±10%)

EZ-1 series

Electrical Trap(Timer Valve)

EZ-1 series

Specifi cations

Features

● Easy installment

● Large orifi ce (4mm) prevent blockage

● Seal material : FPM (Viton)

● Valve connection port : 1/2'' BSP or NPT

● Standard opeartig pressure: 0~1.6MPa

Dimensions

Page 25: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 256 -

Air Dryer

Reference data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

KDXF 320 -

① ② ③

① SeriesKDXF High performance air fi lter

② Type370 Main Filter(20㎛)320 Pre Filter(3㎛)310 Line Filter(1㎛)130 Coalescent Filter(0.01㎛)150 Adsorbent Filter(0.01ppm)

③ In/Out Connection15A Rc(PT)1/2 100A Rc(PT)420A Rc(PT)3/4 125A Rc(PT)525A Rc(PT)1 150A Rc(PT)640A Rc(PT)1 1/2 200A Rc(PT)850A Rc(PT)2 250A Rc(PT)1065A Rc(PT)2 1/2 300A Rc(PT)1280A Rc(PT)3

How to Order

KDXF series

Specifi cations

ModelIn/Out

ConnectionRc(PT)

Flow Capacity (Nm3/min) Dimensions

Weight (kg)

Main Filter(20㎛)

Pre Filter(3㎛)

Line Filter(1㎛)

Coalescent Filter

(0.01㎛)

Adsorbent Filter

(0.01ppm)Width(mm)

High(mm)

370 320 310 130 150KDXF 15A 1/2'' (S) 2.2 1.8 1.2 1.0 1.0 88 278 1.25

KDXF 20A 3/4'' (S) 5.7 3.5 2.8 1.9 1.9 89 500 3.5

KDXF 25A 1'' (S) 8.0 5.7 5.0 3.4 3.4 100 600 4.5

KDXF 40A 1 1/2'' (S) 17.0 14.0 11.0 10.0 10.0 138 835 13.7

KDXF 50A 2'' (S) 29.0 25.0 22.0 14.0 14.0 148 900 21

KDXF 65A 2 1/2'' (F) 58.0 50.0 48.0 28.0 28.0 570 1,210 85

KDXF 80A 3'' (F) 88.0 75.0 72.0 42.0 42.0 570 1,220 95

KDXF 100A 4'' (F) 145.0 125.0 110.0 70.0 70.0 620 1,305 125

KDXF 125A 5'' (F) 174.0 150.0 132.0 84.0 84.0 620 1,305 140

KDXF 150A 6'' (F) 282.0 221.0 176.0 112.0 112.0 812 2,060 250

KDXF 200A 8'' (F) 447.0 331.0 308.0 196.0 196.0 1,000 2,325 340

KDXF 250A 10'' (F) 733.0 555.0 528.0 336.0 336.0 1,200 2,130 400

KDXF 300A 12'' (F) 1,103.0 850.0 792.0 504.0 504.0 1,450 2,130 450

※ For port size : (S) : Screw type, (F) : Flange type.

Features

● Excellent in fi ltering solid material and moisture.● Filter with HEPA absorbent can effi ciently eliminate fi ne particles and

blazed and carbonized particles from air compressor. ● Made of stainess steel, long service life.

Element Model Quantity

KDXE-15A 1

KDXE-20A 1

KDXE-25A 1

KDXE-40A 1

KDXE-50A 1

KDXE-65A 2 (KDXE-50A)

KDXE-80A 3 (KDXE-50A)

KDXE-100A 5 (KDXE-50A)

KDXE-125A 6 (KDXE-50A)

KDXE-150A 11 (KDXE-50A)

KDXE-200A 14 (KDXE-50A)

KDXE-250A 24 (KDXE-50A)

KDXE-300A 36 (KDXE-50A)

Element Quantity

Page 26: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com266 -

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF15A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D

Rc(PT)E

Rc(PT) Element

370 2.2 89 278 262 1/2'' 1/4'' Main Element (40μ)

320 1.8 89 278 262 1/2'' 1/4'' Pre Element (5μ)

310 1.2 89 278 262 1/2'' 1/4'' Line Element (1μ)

130 1.0 89 278 262 1/2'' 1/4'' Coalescent Element (0.01μ)

150 1.0 89 278 262 1/2'' 1/4'' Adsorbent Element (0.01ppm)

No. Element

1 UPPER HOUSING

2 ELEMENT

3 CAP

4 FLOAT

5 NUT

6 DOWN HOUSING

7 STUD BOLT

Structure & Dimensions (KDXF20A-370, 320, 310, 130)

Model Air volume(Nm3/hr) A B C D

Rc(PT)E

Rc(PT) Element

370 5.7 112 490 464 3/4'' 1/4'' Main Element (40μ)

320 3.5 112 490 464 3/4' 1/4'' Pre Element (5μ)

310 2.8 112 490 464 3/4' 1/4'' Line Element (1μ)

130 1.9 112 490 464 3/4' 1/4'' Coalescent Element (0.01μ)

150 1.9 112 490 464 3/4' 1/4'' Coalescent Element (0.01ppm)

No. Element

1 UPPER HOUSING

2 MIDDLE HOUSING

3 ELEMENT COVER CAP

4 DOWN HOUSING

5 AUTO TRAP (PT 1/2'')

6 STUD BOLT

7 ELEMENT

8 CAP

9 BALL VALVE

⑥③④

⑥③④

①②⑥⑦③

④⑧

⑤⑨

①②

Page 27: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 276 -

Air Dryer

Reference data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF25A-370, 320, 310, 130)

No. Element

1 UPPER HOUSING

2 MIDDLE HOUSING

3 ELEMENT COVER CAP

4 DOWN HOUSING

5 AUTO TRAP (PT 1/2'')

6 STUD BOLT

7 ELEMENT

8 CAP

9 BALL VALVE

Model Air volume(Nm3/hr) A B C D

Rc(PT)E

Rc(PT) Element

370 8.0 112 700 674 1'' 1/4'' Main Element (40μ)

320 5.7 112 700 674 1'' 1/4' Pre Element (5μ)

310 5.0 112 700 674 1'' 1/4' Line Element (1μ)

130 3.4 112 700 674 1'' 1/4'Coalescent

Element (0.01μ)

150 3.4 112 700 674 1'' 1/4'Coalescent

Element (0.01ppm)

Structure & Dimensions (KDXF40A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D

Rc(PT)E

Rc(PT) Element

370 29 164 930 892 1/2'' 1/4'' Main Element (40μ)

320 25 164 930 892 1/2'' 1/4'' Pre Element (5μ)

310 22 164 930 892 1/2'' 1/4'' Line Element (1μ)

130 14 164 930 892 1/2'' 1/4''Coalescent

Element (0.01μ)

150 14 164 930 892 1/2'' 1/4'' Adsorbent Element (0.01ppm)

No. Element

1 UPPER HOUSING

2 ELEMENT

3 DOWN HOUSING

4 WRENCH BOLT

5 AUTO TRAP (PT1/2'')

6 DICFLACTAR

7 STUD BOLT

8 ELEMENT COVER CAP

9 CAP

①②⑥⑦

③⑧④

①⑥④⑦②⑧⑨③⑤

①⑥④⑦②⑧⑨③⑤

Page 28: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com286 -

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF50A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D

Rc(PT)E

Rc(PT) Element

370 29 181 1180 1141 2'' 1/4'' Main Element (40μ)

320 25 181 1180 1141 2'' 1/4' Pre Element (5μ)

310 22 181 1180 1141 2'' 1/4' Line Element (1μ)

130 14 181 1180 1141 2'' 1/4'Coalescent

Element (0.01μ)

150 14 181 1180 1141 2'' 1/4'Coalescent

Element (0.01ppm)

No. Element

1 UPPER HOUSING

2 ELEMENT

3 DOWN HOUSING

4 WRENCH BOLT

5 AUTO TRAP (PT 1/2'')

6 DICFLACTAR

7 STUD BOLT

8 ELEMENT COVER CAP

9 CAP

Structure & Dimensions (KDXF65A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D E

Rc(PT) F G H Element

370 58.0 570 1,210 860 140 1/2'' 70 70 (F)2 1/2 Main Element (40μ)

320 50.0 570 1,210 860 140 1/2'' 70 70 (F)2 1/2 Pre Element (5μ)

310 48.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Line Element (1μ)

130 28.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Coalescent Element (0.01μ)

150 28.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 10''

3 IN/OUTLET FLANGE 2 1/2''

4 PRESSURE GAUGE (SOCKET 1/4'')

5 PIPE 10''

6 ELEMENT

7 BOLT (M22×75)

8 FLANGE ANSI 150# SO.RF(10'')

9 NUT (M22)

10 DRAIN NOZZLE (SOCKET 1/2'')

①⑥④⑦②⑧⑨③⑤

①⑥④⑦②⑧⑨③

①②③

⑦⑧⑨⑩

①②③

⑦⑧⑨⑩

Page 29: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 296 -

Air Dryer

Reference data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF80A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D E

Rc(PT) F G H Element

370 88.0 570 1,220 860 140 1/2'' 70 70 (F)3'' Main Element (40μ)

320 75.0 570 1,220 860 140 1/2'' 70 70 (F)3'' Pre Element (5μ)

310 72.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Line Element (1μ)

130 42.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Coalescent Element (0.01μ)

150 42.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 10''

3 IN/OUTLET FLANGE 3''

4 PRESSURE GAUGE (SOCKET 1/4'')

5 PIPE 10''

6 ELEMENT

7 BOLT (M22×75)

8 FLANGE ANSI 150# SO.RF(10'')

9 NUT (M22)

10 DRAIN NOZZLE(SOCKET 1/2'')

Structure & Dimensions (KDXF100A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D E

Rc(PT) F G H Element

370 145.0 620 1,305 860 140 1/2'' 70 70 (F)4'' Main Element (40μ)

320 125.0 620 1,305 860 140 1/2'' 70 70 (F)4'' Pre Element (5μ)

310 110.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Line Element (1μ)

130 70.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Coalescent Element (0.01μ)

150 70.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 12''

3 IN/OUTLET FLANGE 4''

4 PRESSURE GAUGE (SOCKET 1/4'')

5 PIPE 12''

6 ELEMENT

7 BOLT (M22×75)

8 FLANGE (12'')

9 NUT (M22)

10 DRAIN NOZZLE (SOCKET 1/2'')

①②

⑦⑧⑨⑩

①②

⑦⑧⑨⑩

①②

⑦⑧⑨⑩

①②

⑦⑧⑨⑩

Page 30: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com306 -

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF125A-370, 320, 310, 130, 150)

Model Air volume(Nm3/hr) A B C D E

Rc(PT) F G H Element

370 174.0 620 1,306 860 140 1/2'' 70 70 (F)5'' Main Element (40μ)

320 150.0 620 1,305 860 140 1/2'' 70 70 (F)5'' Pre Element (5μ)

310 132.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Line Element (1μ)

130 84.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Coalescent Element (0.01μ)

150 84.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 12''

3 IN/OUTLET FLANGE 5''

4 PRESSURE GAUGE (SOCKET 1/4'')

5 PIPE 12''

6 ELEMENT

7 BOLT (M22×75)

8 FLANGE (12'')

9 NUT (M22)

10 DRAIN NOZZLE (SOCKET 1/2'')

Structure & Dimensions (KDXF150A-370, 320, 310)

Model Air volume(Nm3/hr) A B C D E F G H Element

370 282.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Main Element (40μ)

320 221.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Pre Element (5μ)

310 176.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Line Element (1μ)

No. Element

1 EYE BOLT 3/4''

2 CAP 16''

3 IN/OUTLET FLANGE 6''

4 PRESSURE GAUGE NOZZLE1/4''

5 PIPE 16''

6 ELEMENT

7 BOLT (B24×80)

8 FLANGE (16'')

9 NUT (M24)

10 DRAIN NOZZLE (1/2'')

①②③

⑦⑧⑨⑩

①②

⑦⑧⑨⑩

①②③

⑦⑧⑨⑩

①②③

⑦⑧⑨⑩

Page 31: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 316 -

Air Dryer

Reference data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF150A-130, 150)

Model Air volume(Nm3/hr) A B C D E F G H Element

130 112.0 812 2,059.8 970 850 406.4 100 1/4'' (F)6'' Coalescent Element (0.01μ)

150 112.0 812 2,059.8 970 850 406.4 100 1/4'' (F)6'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 16''

3 IN/OUTLET FLANGE 6''

4 PRESSURE GAUGE 1/4''

5 PIPE 16''

6 ELEMENT

7 BOLT (B24×80)

8 FLANGE (16'')

9 NUT (M22)

10 DRAIN NOZZLE (SOCKET 1/2'')

Structure & Dimensions (KDXF200A-370, 320)

Model Air volume(Nm3/hr) A B C D E F G H Element

370 447.0 1,000 2,326 1,327 673 508 130 1/4'' (F)8'' Main Element (40μ)

320 331.0 1,000 2,626 1,327 673 508 130 1/4'' (F)8'' Pre Element (5μ)

No. Element

1 EYE BOLT 3/4''

2 CAP 20''

3 IN/OUTLET FLANGE 8''

4 PRESSURE GAUGE NOZZLE 1/4''

5 PIPE 20''

6 ELEMENT

7 BOLT (B24×95)

8 FLANGE (20'')

9 NUT (M24)

10 DRAIN NOZZLE 1/2''

①②③

⑦⑧⑨

①②③

⑦⑧⑨

Page 32: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com326 -

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF200A-310, 130, 150)

Model Air volume(Nm3/hr) A B C D E F G H Element

310 308.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Line Element (1μ)

130 196.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Coalescent Element (0.01μ)

150 196.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 20''

3 IN/OUTLET FLANGE 8''

4 PRESSURE GAUGE NOZZLE 1/4''

5 PIPE 20''

6 ELEMENT

7 BOLT (B24×95)

8 FLANGE (20'')

9 NUT (M24)

10 DRAIN NOZZLE 1/2''

Structure & Dimensions (KDXF250A-370, 320)

Model Air volume(Nm3/hr) A B C D E F G H Element

370 733.0 1,200 2,130 990 745 609.6 80 1/4'' (F)10'' Main Element (40μ)

320 555.0 1,200 2,130 990 745 609.6 80 1/4'' (F)10'' Pre Element (5μ)

No. Element

1 EYE BOLT 3/4''

2 CAP 24''

3 IN/OUTLET FLANGE 10''

4 PRESSURE GAUGE NOZZLE1/4''

5 PIPE 24''

6 ELEMENT

7 BOLT (B24×80)

8 FLANGE (24'')

9 NUT (M30)

10 DRAIN NOZZLE (1/2'')

①②③

⑦⑧⑨

①②③

⑧⑨

Page 33: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com 336 -

Air Dryer

Reference data

KDHR

KDHR-W

KDHT

KDAH

KDAE

KDAE-S

KDAO

KDAB

KDNP

KDH-C

KDRC

SEPREMIUM

KDRT

KDHAD

EZ-1

KDXF

KDXE

PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter

Structure & Dimensions (KDXF250A-310)

Model Air volume(Nm3/hr) A B C D E F G H Element

310 528.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Line Element (1μ)

No. Element

1 EYE BOLT 3/4''

2 CAP 26''

3 IN/OUTLET FLANGE 10''

4 PRESSURE GAUGE 1/4''

5 PIPE 26''

6 ELEMENT

7 BOLT (B24×80)

8 FLANGE (26'')

9 NUT (M30)

10 DRAIN NOZZLE 1/2'')

Structure & Dimensions (KDXF250A-130, 150)

Model Air volume(Nm3/hr) A B C D E F G H Element

130 336.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Coalescent Element (0.01μ)

150 336.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Adsorbent Element (0.01ppm)

No. Element

1 EYE BOLT 3/4''

2 CAP 26''

3 IN/OUTLET FLANGE 10''

4 PRESSURE GAUGE NOZZLE1/4''

5 PIPE 26''

6 ELEMENT

7 BOLT (B24×80)

8 FLANGE (246')

9 NUT (M30)

10 DRAIN NOZZLE (1/2'')

①②③

⑨⑩

①②③

⑦⑧⑨⑩

Page 34: 06| AIR DRYER - zmtechnik.sk · KDRT KDHAD EZ-1 KDXF KDXE PNEUMATIC & HYDRAULIC Desiccant Performance Table Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃

KCC Co., Ltd.

www.kccpr.com346 -

PNEUMATIC & HYDRAULIC KDXE seriesFilter Element

KDXE 370 - 15A

① ② ③

How to Order

KDXE series

Specifi cations

KDXE370KDXE320 KDXE310 KDXE130 KDXE150

ModelMAIN PRE LINE COALESCENT ADSORBENT

KDXE-370, 320 KDXE-310 KDXE-130 KDXE-150

Structure

Filtering 100% remove solid substance above 20㎛

100% remove solid substance above1㎛

100% remove solid substance above0.1㎛

100% remove solid substance above0.01㎛

Material Sintered resin Hepa Hepa/Polyester Hepa/Polyester/Active carbon paper

Application

Eliminate liquid, oil, rust debris and any particle larger than 3㎛. Most commonly used.

For shear tools or general air tools.

Eliminate 99% of spray paint and oil vapor. Does not remove smell.

Strengthened elimination of oil vapor. For precision electronics, semiconductor, pharmaceutical manufacturing process.

Installation place

Installed at the production main line or before refrigerated air dryer and filter (KDXE-310m 130, 150).Essential for long piping line to prevent flow in of condensate water.

Installed at the end of production line or on a desiccant dryer. And, by installed it before filter KDXE-130 or KDXE-150 will extend service life of the filter.

Installed at the part where oil and water need to be totaly eliminated. Install it before desiccant air dryer will strengthen dehumidification efficiency and prolong the life of the adsorbent.

It is the filter installed at the end of the line to eliminate solid object which is greater than 0.01㎛. An essential equipment for the site requires clear compressed air.

Maintenance & replacement

Clean element with neutral cleaser when pressure difference become 0.07MPa (0.7kg/cm2). Do not use gasoline or thinner.

Replace a new cartridge if the differential pressure become 0.5kg/cm2(0.05MPa) or above.

Features

● One-touch attaching type element allows easy replacement. ● Various media type element to eliminate corpuscles, oil

mist, moisture, gas and etc.

One-touch attaching type element

Type 15A 20A 25A 40A 50A

Dimensions (mm) 48×105 48×150 48×200 78×450 78×460

Dimensions

① SeriesKDXE Filter element

② Type370 Main Filter(20㎛)320 Pre Filter(3㎛)310 Line Filter(1㎛)130 Coalescent Filter(0.01㎛)150 Adsorbent Filter(0.01ppm)

③ Applicable Dimensions15A For 1/2 20A For 3/425A For 140A For 1 1/250A For 2


Recommended