AIR DRYER06|
Reference Data [6] - 2
Refrigerated Air Dryer
KDHR Air cooled [6] - 7
KDHR-W Water cooled [6] - 11
KDHT High temperature [6] - 12
Desiccant Air Dryer
KDAH Heatless [6] - 13
KDAE Heater [6] - 14
KDAE-S Heater, skid [6] - 15
KDAO Oiless [6] - 16
KDAB Heater blower [6] - 17
KDNP Non-purge [6] - 18
KDH-C After Cooler [6] - 19
KDRC Chiller [6] - 20
SEPREMIUM Oil-Water Separator [6] - 21
KDRT Receiver Tank [6] - 22
KDHAD Auto Drain Trap [6] - 23
EZ-1 Electrical Trap [6] - 24
KDXF Filter [6] - 25
KDXE Filter Element [6] - 34
KCC Co., Ltd.
www.kccpr.com26 -
PNEUMATIC & HYDRAULIC
Refrigerated Type
Desiccant Type
R/D A/C A/D A B C D E F G H I
1. Food, beverage, dairy industry
2. Chemical (Clean transportation)
1. Hospital(Breathing system) Medical (Packing)
2. Photograph printing, Fiber
2. Powder coating
3. Measurement/Controlling Equipment
4. Common industry
5. Sand blasting
A/C R/D
C
C
C
F
D
E
E
B
G
G
H
I
Compressor
Refrigerated Air DryerAfter CoolerDesiccant Air DryerWater SeparatorCoalescing FilterCoalescing FilterCoalescing FilterActivated Carbon FilterPre-FilterSterile FilterDesiccant Air DryerOil-Water Separator
::::::::::::
2. Optical industry
1. Breathing system, surgery system
2. Paint spray, production
3. Transfer system (Antifreeze)
Microorganismn
Wet Air
Dry Air
A/DF
D
Compressor
F
E
G
E
G
I
Oil Mist
Solid Particle 1. Medical, food, beverage industry
Air Dryer
Reference Data
KCC Co., Ltd.
www.kccpr.com 36 -
Air Dryer
Reference Data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC
Desiccant Performance Table
■ Saturated vapor volume table shows absolute humidity is 30.3g/m3 at 30℃
■ Dew point under ATM conversion chart shows dew point -23℃ under ATM at 4℃ under 7kg/cm2G
Dew Point under ATM Conversion Chart
Relative Humidity (%)
Molecular Sieves
Absorption R
ate W (%
)
Silica Gel
Alumina(Spherical)
Alumina(Granular)
Saturated Vapor Volume Table (g/m3)
-50 0.0617 -16 1.48 18 15.4-49 0.0689 -15 1.61 19 16.3-48 0.0767 -14 1.74 20 17.3-47 0.0853 -13 1.88 21 18.3-46 0.0950 -12 2.03 22 19.4-45 0.106 -11 2.19 23 20.6-44 0.117 -10 2.46 24 21.8-43 0.130 -9 2.54 25 23.0-42 0.144 -8 2.74 26 24.4-41 0.159 -7 2.95 27 25.8-40 0.176 -6 3.17 28 27.2-39 0.194 -5 2.41 29 28.7-38 0.214 -4 3.66 30 30.3-37 0.236 -3 3.93 31 32.0-36 0.260 -2 4.22 32 33.8-35 0.286 -1 4.52 33 35.6-34 0.314 0 4.85 34 37.5-33 0.345 1 5.19 35 39.6-32 0.378 2 5.56 36 41.7-31 0.414 3 5.95 37 43.9-30 0.453 4 6.36 38 46.2-29 0.496 5 6.79 39 48.6-28 0.542 6 7.26 40 51.5-27 0.592 7 7.75 41 53.7-26 0.646 8 8.27 42 56.4-25 0.705 9 8.82 43 59.3-24 0.768 10 9.40 44 62.2-23 0.863 11 10.0 45 65.3-22 0.909 12 10.7 46 68.5-21 0.989 13 11.3 47 71.9-20 1.07 14 12.1 48 75.4-19 1.17 15 12.8 49 79.0-18 1.26 16 13.6 50 82.8-17 1.37 17 14.5
Air Dryer
Reference Data
Pres
sure
kgf/c
m2 G
ATM
Dew point under ATM (℃)
Dew
poi
nt u
nder
pre
ssur
e ( ℃
)
KCC Co., Ltd.
www.kccpr.com46 -
PNEUMATIC & HYDRAULIC
Functions Description
Warm and humid air enters air to air heat exchanger, not mixed with cold air. The cooled air condenses the saturated air to minimize heat load. The condensate is removed through drain, and the cooled air flows into air to refrigerant heat exchanger again to cool down to 4℃-10℃. The moisture of the compressed air is separated by the impingement separator, and automatically discharged. The cool air is reheated by the warm air flowed in, and flows out through air to air heat exchanger. Reheat increases the volume of air, decreasing relative humidity.
Installation
Please read carefully the following before installing Air Dryer for extended use without breakdown.
1) Appropriate installation place for air dryer● Flat place● Place without acidic or alkaline substances● Place without combustible gas● Place easy for air piping and electric wiring ● Place without dust and vibration● Place easy to check and repair the product● Place with appropriate ambient temperature in winter and summer (1.7℃ - 40℃)
2) Precautions for Installationa) A minimum space of 1.5M or more for the product shall be secured for sufficient fresh air and easy maintenance.b) The strength of the base for installation shall be considered before installation, and foundation work shall be done, if the ground is unstable.
※ Places to Particularly AvoidSlope, place with severe vibration, place exposed to direct sunlight, heated place, place exposed to rains, place with much dust and pollutants, place with bad ventilation, and place with standard service temperature (1.7℃ - 40℃) unavailable.
a) If the temperature falls below 2℃, the inside of drain trap may be frozen.
b) If the temperature rises above 40℃, air dryer may stop working.
Pressure & Temperature Conversion Multiplier Table
Inlet pressure (kgf/cm2) 3 4 5 6 7 8 9 10 11 12 13 14 15
Conversion factor(C1) 0.74 0.84 0.91 0.96 1.00 1.04 1.06 1.09 1.11 1.12 1.14 1.15 1.17
Ambient temperature (℃) 25 30 35 38 40 43 45 50
Conversion factor(C2) 1.16 1.11 1.06 1.00 0.95 0.89 0.84 0.78
Inlet temperature (℃) 30 35 38 40 43 45 50 55 60
Conversion factor(C3) 1.32 1.15 1.00 0.92 0.83 0.78 0.65 0.52 0.39
Processing Capacity Setting Method (FA)FA = Processing Flow x C1 x C2 x C3
Air Dryer
Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)
KCC Co., Ltd.
www.kccpr.com 56 -
Air Dryer
Reference Data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC
Wiring
a) Electric Wire
The capacity of power cable is as follows.
b) A single-phase circuit breaker for wiring shall be installed for overload protection and to prevent an electric shock due to leakage before installing air dryer.
c) Be sure to install Ground Cord. (Third-class grounding work is required.)
d) Dryer shall be operated within ±5 % of the standard voltage to meet the rated power.
Model KDHR-5-30
KDHR-50
KDHR-75-100 KDHR-500 ~
Rated Power AC 220V / 3PH / 60Hz 220V/380V/440V/3PH/60Hz
Power cable (mm2)
1.25 or more
2.0 or more 5.5 or more
How to Operate
1) Start-up
After installation is completed, start-up shall be provided after thoroughly checking the following.
※ Checkpointsa) Aren’t there any problems in the installed air-pressure pipe and line?b) Is the valve of BY-PASS pipe closed?c) Is the valve of Drain Discharge pipe opened?
※ Checkpoints for Powera) Is voltage normal?b) Isn’t the capacity of fuse circuit breaker for wiring different from the designated.
2) How to Operate
Press the ON button of the power switch.
※ If the power lamp is lighted, operation starts. If the needle on the refrigerant pressure gauge indicates 2.5~3.5kgf/cm2
(R-134c)~3.5~5.5kgf/cm2(R-22) in one minute after the refrigeration compressor has started to operate, it means a normal state.※ In 5 minutes after operation, compressed air flows in slowly while the air compressor is in operation. (Be careful that pressure is not loaded on air dryer at once.)
※ NoteTo restart after stop, an interval of 5 minutes or more is required.
Daily Opertion Method
1) Press the operation switch.2) The RUN lamp is lighted, and the refrigeration compressor is operated.3) Check if the needle on the refrigerant pressure gauge indicates 4~4.5kgf/cm2
4) Allow compressor air to flow in 5 minutes after operation.
Safety Device
For safe use, it has a safety device mounted. If the safety device functions,Air dryer stops automatically.1) Electric Circuit: Motor Protector If over current flows in Refrigeration Compressor, motor protector works to stop air dryer.2) How to Release a) Remove the cause of stop (see Causes of Failure and Measures.) b) Press the START button for operation.
Tips for Hot Gas Bypass Valve Adjustment
1) Since the hot gas bypass valve has been adjusted when shipped, it shall be adjusted only if abnormalities are found. Loosen the nut of the valve, and adjust the valve with a driver, seeing the refrigerant pressure gauge, until the needle on the refrigerant pressure gauge is within the normal scope.
Pressure Scope of Refrigerant R-22- Low Pressure : 0.4~0.45MPa(4~ 4.5kgf/cm2)- High Pressure : 1.3~1.75MPa(13 ~ 20kgf/cm2)
Air Dryer
Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)
Piping
The assembly of pipes shall be adjusted, using tools such as a wrench, and piping shall be provided for sections with defective screws to prevent air leakage. If not fixed, the case may be damaged.a) The inlet and outlet of air dryer shall be correctly connected in piping.b) Be careful that the weight of piping is not loaded on the body.c) Make sure that the vibration of air compressor is not transmitted to dryer, and avoid vertical piping.d) Install a by-pass pipe between inlet and outlet of air dryer.e) For convenience purpose, union or fl ange shall be applied to the inlet and outlet of dryer for connection.f) Zinc-plated pipe shall be used.g) The condensed water from the drain outlet shall be discharged to the outside through a separate drainpipe. Note: ※ Be sure to close by-pass valve while in use.※ Since if the drainpipe is vertical or extended, pressure is produced in the pipe, the condensed water may not be discharged.
KCC Co., Ltd.
www.kccpr.com66 -
PNEUMATIC & HYDRAULIC
Daily Check & Cleaning
1) Daily Checks a) Check the Auto Drain Trap. b) Check if the timer of Electronic Trap has been correctly set (ON 2 seconds, OFF 2 minutes). c) Check if there are any air leaks. d) Check if it works normally. (Check if water comes out.) e) Check inlet temperature for compressed air and ambient temperature, and clean Condenser and After cooler for the removal of dust on a regular basis.2) Cleaning a) Cleaning of Condenser • Clean the condenser on a regular basis, using a vacuum cleaner, a brush, or an air gun. • Dryer cases shall have both sides disassembled one by one. • If dust is accumulated on the condenser, it is not only good for heat exchange, but also may stop the operation of air dryer as safety device works, if severe.
※ Note Be careful not to deform the fins of Condenser while cleaning. b) Cleaning of Auto Drain Trap (Solenoid Valve) • Disassemble and clean the auto drain trap on a regular basis for a regular operation all the time.
Causes of Failure & Measures If failure is suspected while using, please check the following.
Causes
Symptoms
Refrigerant leaks
Thermal R
elay is defective
Bypass Valve is opened
Light from Lam
p is blocked
Sw
itch is defective
Pow
er voltage is too low
Refrigeration C
ompressor is
defective
Solenoid Valve is defective
Solenoid Valve has foreign
substance
Solenoid Valve has been
frozen
Air processing volum
e is too m
uch
Cooling capacity has
decreased
Hot G
as Bypass Valve is
defective
Condenser is clogged
The ambient tem
perature is too high
Fan Motor is defective
Com
presser Magnet is
defective
Pressure S
witch for fan control
is defective
Even though the switch is turned ON, it does not operate.
Operation Lamp is OFF ● ● ● ● ●
Operation Lamp is ON ● ●Water and oil come out while the needle on the refrigerant pressure gauge indicates normal. ● ● ● ● ●
he needle on the refrigerant pressure gauge indicates high pressure, and water and oil come out. ● ● ● ● ● ● ● ● ● ●
Condensed water is not discharged from the Auto Drain. ● ● ●
The temperature of Air Outlet is equal to or higher than that of Air Inlet. ● ● ● ● ●
The machine has stopped during operation. ● ● ● ● ● ● ● ● ●
High Pressure Alarm Lamp is lighted. ● ● ● ● ● ●
Over Current Alarm Lamp is lighted. ● ● ● ●
Measures
Check gas leak areas
Exchange
Close the B
ypass Valve
Exchange
Exchange
Use R
egulated Voltage
Exchange
Exchange
Disassem
ble and Clean
Set the am
bient temperature to m
ore than 2℃
Air processing volum
e shall be set at the normal
Check gas leakage and refrigerant am
ount
Exchange and A
djust
Clean
Lower the am
bient temperature
Exchange
Exchange
Exchange
Air Dryer
Reference Data of Air Cooled Refrigerated Air Dryer (KDHR)
KCC Co., Ltd.
www.kccpr.com 76 -
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)
KDHR - 5
① ②
① SeriesKDHR Air cooled type refreigerated air dryer
② Size5, 7, 10, 15, 20, 30, 50, 75, 100,
150, 200, 250, 300, 400, 500, 600, 800
How to Order
KDHR series
Specifi cations
ModelFlow Capacity(Nm3/min) Connection
Rc(PT) Freon GasElectrical Power Dimensions (mm)
Weight (kg)60Hz 50Hz V A KW Width Length Height
KDHR-5 0.62 0.57 3/4" (S)
R-134a
AC1Ph
220V60Hz
1.14 0.2 310 575 535 40
KDHR-7 0.97 0.89 3/4" (S) 1.14 0.2 310 575 535 40
KDHR-10 1.35 1.23 3/4" (S) 2.5 0.4 310 575 535 40
KDHR-15 1.96 1.8 3/4" (S) 3.5 0.8 310 670 560 45
KDHR-20 2.6 2.4 1" (S)
R22
6.1 0.9 320 700 670 84
KDHR-30 3.9 3.5 1" (S) 5.1 0.9 320 700 670 86
KDHR-50 7.2 6.6 2" (S) 6 1.0 411 1,020 940 117
KDHR-75 11.1 10.5 2" (S) 10 1.9 411 1,020 940 170
KDHR-100 14.6 13.3 2" (S) 12.5 2.8 411 1,030 1,030 196
KDHR-150 21.9 20.0 3" (F)
AC3Ph
220V/380V/440V60Hz
12.2 3.8 700 1,100 1,600 325
KDHR-200 31.3 28.6 3" (F) 17.0 5.2 700 1,100 1,600 380
KDHR-250 40.1 36.6 4" (F) 17.0 5.2 900 1,700 1,800 468
KDHR-300 47.6 43.5 4" (F) 17.0 5.2 900 1,700 1,800 660
KDHR-400 59.5 54.3 4" (F) 26.5 5.6 1,000 2,000 1,800 790
KDHR-500 73.9 67.5 6" (F) 16 12.2 2,500 1,250 2,500 1,560
KDHR-600 89.6 81.8 6" (F) 17 12.2 2,500 1,250 2,500 1,700
KDHR-800 112.5 102.7 8" (F) 21 13.8 2,500 1,250 2,500 1,780
※ In/Out Connection : (S) Screw, (F) Flange
Dew Point Operating Pressure Fluid Inlet Temperature Ambient Temperature Condenser
1.7℃~4℃7.0kg/cm2(0.7MPa)
Max:9.9kg/cm2(0.99MPa) Compressed Air 40℃ 1.7℃~40℃ Air Cooled
※ Coefficient of air flow capacity: inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating dew point 4℃
Features
● Specially designed heat exchanger eliminated minute moisture in the
high temperature and high humidity compressed air through rapid
cooling cycle.● Easy disassembling case serve for easy A/S and maintenance.
KCC Co., Ltd.
www.kccpr.com86 -
PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)
Dimensions (KDHR 05~15)
Unit:mm
Model A B C D E F G H I J K L N M O P Q S
KDHR5~10 6A 665 50 100 22 325 410 510 50 100 310 50 85 75 10 37 66 68
KDHR15 6A 700 50 100 22 360 410 510 50 100 310 85 85 75 10 37 66 68
Dimensions (KDHR 20~30)
KCC Co., Ltd.
www.kccpr.com 96 -
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)
Dimensions (KDHR 50~100)
Unit:mm
Model A B C D E F G H I K L N M O P Q S T W X Y
KDHR 50 940 60 180 420 180 60 60 20 37 66 68 15 490 15 640 60 700 60 140 820 1 1/2"(40A)
KDHR 75 1,090 60 180 570 180 60 50 20 37 66 68 15 570 15 930 70 830 70 175 970 2"(50A)
KDHR 100 1,190 60 180 670 180 60 50 30 37 66 68 15 570 15 990 80 910 80 175 1,070 2"(50A)
Dimensions (KDHR 150~400)
Unit:mm
Model A B C D E F G H I J K L N M O P Q S T W Y X
KDHR150~250 800 200 250 200 250 80 20 125 100 330 1,700 1,800 300 15 900 15 350 300 350 350 1,700 350
KDHR300~400 1,000 200 300 200 300 80 20 125 100 330 1,700 1,800 300 25 1,000 25 350 300 350 400 2,000 400
KCC Co., Ltd.
www.kccpr.com106 -
PNEUMATIC & HYDRAULIC KDHR seriesRefrigerated Air Dryer (Air Cooled Type)
Dimensions (KDHR 500~800)
Unit:mm
Model A B C D E F G H I J K L N M O P Q S T W Y X Z ZZ
KDHR 500 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 5" 1,122 1,200 1,272 6"
KDHR 600 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 5" 1,122 1,200 1,272 6"
KDHR 800 2,800 850 1,150 250 800 200 150 300 750 325 1,500 2,500 1,000 325 550 325 1,200 1,000 550 6" 1,122 1,200 1,272 8"
KCC Co., Ltd.
www.kccpr.com 116 -
Air Dryer
Reference Data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDHR-W seriesRefrigerated Air Dryer (Water Cooled Type)
KDHR - 400 W
① ② ③
① SeriesKDHR Refrigerated air dryer
② Size400, 500, 600, 750, 900, 1,200, 1,500,
2,000, 3,000, 4,000, 5,000, 6,000
How to Order
KDHR-W series
Specifi cations
ModelFlow Capacity (Nm3/min) In/Out Connection
(Air)Rc(PT)
In/Out Connection (Water)Rc(PT)
Cooling Water(ℓ/min)
Refrigeration Compressor
(HP)Weight
(Kg)60Hz 50Hz
KDHR-400W 63.6 58.1 4"(F) 1 1/2"(S) 53/105 7 1/2 640
KDHR-500W 79.1 72.2 6"(F) 2"(S) 64/127 10 1,490
KDHR-600W 95.8 87.5 6"(F) 2"(S) 80/159 10 1,570
KDHR-750W 120.3 109.8 8"(F) 2"(S) 105/210 15 1,620
KDHR-900W 155.3 141.8 8"(F) 2 1/2"(F) 158/315 20 1,740
KDHR-1200W 177.6 162.1 8"(F) 2 1/2"(F) 183/365 20 1,890
KDHR-1500W 221.9 202.6 10"(F) 2 1/2"(F) 210/420 30 1,970
KDHR-2000W 295.8 270.1 12"(F) 3"(F) 265/530 40 2,180
KDHR-3000W 473.3 432.1 14"(F) 3"(F) 424/848 60 2,320
KDHR-4000W 591.7 540.2 16"(F) 4"(F) 530/1,060 80 2,540
KDHR-5000W 709.9 648.1 18"(F) 5"(F) 636/1,272 100 2,760
KDHR-6000W 887.4 810.1 20"(F) 5"(F) 795/1,590 130 3,110
※ In/Out Connection : (S) Screw, (F) Flange
Refrigerant Dew Point Max Operating Pressure Fluid Inlet Temperature Ambient
Temperature Condenser Electrical Power
R22 1.7℃~4℃9.9kg/cm2
(0.95MPa) Compressed Air 45℃ 1.7℃~45℃ Water Cooled AC 3Ph 220V/380V/440V 60Hz
※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, cooling water inlet temperature 17℃~30℃, cooling pressure range 2kgf/cm2(0.2MPa) ~ 4.5kgf/cm2(0.45MPa), operating dew point 4℃
③ Cooling TypeW Water Cooled
Features
● Refrigerant is condesed by water cooled-condenser when going through
refrigeration cycle, it produces stable refrigeration cycle.
KCC Co., Ltd.
www.kccpr.com126 -
PNEUMATIC & HYDRAULIC KDHT seriesRefrigerated Air Dryer (High Temperature Type)
KDHT - 5
① ②
① SeriesKDHT High temperature type refrigerated air dryer
② Size5, 7, 10, 15, 20, 30, 50
How to Order
KDHT series
Specifi cations
ModelFlow Capacity (Nm3/min) In/Out
ConnectionRc(PT)
Freon GasDimensions (mm)
Weight (kg)60Hz 50Hz Width Length Height
KDHT-5 0.62 0.57 3/4"
R-134a
320 600 860 52
KDHT-7 0.97 0.89 3/4" 320 600 860 54
KDHT-10 1.35 1.23 3/4" 320 600 860 56
KDHT-15 1.96 1.8 3/4" 320 600 860 67
KDHT-20 2.63 2.4 1"
R22
400 800 1,060 93
KDHT-30 3.85 3.5 1" 400 800 1,060 98
KDHT-50 7.24 6.6 1" 700 1,100 1,250 130
Features
● A combination type air dryer with built-in after cooler make it easy to be
installed at narrow space. Standard specifi cations include main line fi lter.
Dew Point Operating Pressure Fluid Inlet Temperature Electrical Power
4℃7.0kg/cm2(0.7MPa)
Max:9.9kg/cm2(0.99MPa)
Compressed Air 55℃Max:80℃
1Ph 220V 60Hz
※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating dew point 4℃
KCC Co., Ltd.
www.kccpr.com 136 -
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDAH seriesDesiccant Air Dryer (Heatless Type)
KDAH - 5
① ②
① SeriesKDAH Desiccant Air Dryer
② Size5, 7, 10, 20, 30, 40, 50, 75, 100, 130,
150, 170, 200, 250, 300, 400, 450, 500, 600, 750, 900
How to Order
KDAH series
Specifi cations
Model Flow Capacity (Nm3/hr)
In/Out ConnectionRc(PT)
Gel/2 Tower (kg)
Dimensions (mm)Weight (kg)
Width Length Height
KDAH-5 28 1/2"(S) 10 700 500 1,050 70
KDAH-7 55 1/2"(S) 22 750 550 1,300 115
KDAH-10 91 3/4"(S) 30 750 550 1,600 158
KDAH-20 173 1"(S) 62 850 700 1,900 225
KDAH-30 247 1"(S) 90 950 750 1,800 275
KDAH-40 356 1 1/2"(S) 100 1,000 750 1,900 320
KDAH-50 526 1 1/2"(S) 136 1,050 900 1,950 380
KDAH-75 651 1 1/2"(S) 176 1,100 900 2,450 490
KDAH-100 838 2"(S) 222 1,250 1,000 2,550 590
KDAH-130 975 2"(S) 258 1,250 1,000 2,350 615
KDAH-150 1,247 2"(S) 283 1,300 1,000 2,500 675
KDAH-170 1,511 2 1/2"(F) 392 1,350 1,050 2,650 845
KDAH-200 1,778 2 1/2"(F) 490 1,450 1,100 2,750 985
KDAH-250 2,160 3"(F) 546 1,550 1,200 2,550 1,145
KDAH-300 2,576 3"(F) 656 1,650 1,300 2,550 1,225
KDAH-400 3,089 3"(F) 910 1,850 1,400 2,650 1,570
KDAH-450 3,557 4"(F) 1,276 2,100 1,550 2,850 2,190
KDAH-500 4,058 4"(F) 1,430 2,100 1,600 2,890 2,400
KDAH-600 5,796 6"(F) 2,032 2,400 1,850 3,080 3,220
KDAH-750 7,371 6"(F) 2,380 2,600 2,150 3,100 4,560
KDAH-900 8,946 6"(F) 3,088 3,000 2,150 3,100 5,600
※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet pressure 7.0kgf/cm2(0.7MPa), inlet temperature 38℃, ambient temperature 38℃, operating pressure 7kgf/cm2, dew point -40℃
Features
● KDAH series are designed for reliable dew point -40℃(Atm).● Suitable for 4 seasons and parts are easy to repair.
KCC Co., Ltd.
www.kccpr.com146 -
PNEUMATIC & HYDRAULIC KDAE seriesDesiccant Air Dryer (Heater Type)
KDAE - 20
① ②
① SeriesKDAE Desiccant air dryer with heater
② Size20, 40, 50, 75, 100, 130, 150, 200, 250, 280, 300, 400, 500, 600,
750, 900, 1,200, 1,500, 2,000
How to Order
KDAE series
Specifi cations
Model Flow Capacity(Nm3/hr)
In/Out Connection
Rc(PT)Gel/Tower
(kg)Heater
(kw)Dimensions (mm)
Weight (kg)Width Length Height
KDAE-20 158 1"(S) 74 2 1,250 900 1,700 340
KDAE-40 391 1 1/2"(S) 136 3 1,450 1,000 1,950 540
KDAE-50 523 1 1/2"(S) 174 4.5 1,450 1,100 2,380 745
KDAE-75 627 1 1/2"(S) 223 5.5 1,550 1,100 2,450 905
KDAE-100 914 2"(S) 300 7.5 1,550 1,150 2,450 1,130
KDAE-130 998 2"(S) 394 9.5 1,750 1,150 2,600 1,380
KDAE-150 1311 2 1/2"(F) 490 12 1,850 1,500 2,600 1,620
KDAE-200 1,764 2 1/2"(F) 558 15 1,900 1,500 2,800 1,850
KDAE-250 2,048 3"(F) 750 18.5 1,950 1,500 2,800 2,060
KDAE-280 2,394 3"(F) 882 20 2,000 1,600 2,800 2,440
KDAE-300 2,804 3"(F) 1,052 25 2,200 1,600 2,650 2,990
KDAE-400 3,517 4"(F) 1,430 32 2,400 1,800 2,950 3,930
KDAE-500 4,486 4"(F) 1,688 40 2,550 1,900 2,900 4,500
KDAE-600 5,130 6"(F) 2,448 60 3,000 2,150 3,200 5,960
KDAE-750 6,930 6"(F) 2,864 70 3,300 2,150 3,100 6,750
KDAE-900 9,006 6"(F) 3,100 100 3,700 2,750 3,650 10,630
KDAE-1,200 11,028 8"(F) 4,590 110 4,200 3,000 3,150 11,200
KDAE-1,500 12,600 9"(F) 5,264 125 4,200 3,350 3,900 12,800
KDAE-2,000 15,750 10"(F) 6,580 160 4,600 3,200 3,300 16,700
※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet temperature 38℃, ambient temperature 38℃, operating pressure 7kgf/cm2, dew point -50℃
Features
● KDAE Series are designed for reliable dew point under -70℃(Atm) with
minimizing overheating of heater. 2 way butterfly valve is installed in all
products. Dehumidification time can be extended regarding to load.
● Option
Dew Point Control:Dehumidification time can be extended regarding to
load.
KCC Co., Ltd.
www.kccpr.com 156 -
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDAE-SDesiccant Air Dryer (Heater, Skid Type)
KDAE - 20 S
① ② ③
① SeriesKDAE Deciccant air dryer with heater
③ TypeS Skid
② Size50, 75, 100, 130, 150, 200, 250, 300, 400, 500, 600, 750, 1550,
3000, 4100
How to Order
KDAE-S series
Specifi cations
Model Flow Capacity(Nm3/hr)
In/Out Connection
Rc(PT)Gel/ Tower
(kg)Heater
(kw)Dimensions (mm)
Weight (kg)Width Length Height
KDAE-50S 523 1 1/2'' 174 4.5 1,450 1,500 2,380 890
KDAE-75S 627 1 1/2'' 223 5.5 1,550 1,500 2,450 985
KDAE-100S 914 2'' 300 7.5 1,750 1,700 2,450 1,320
KDAE-130S 998 2'' 394 9.5 1,750 1,700 2,600 1,550
KDAE-150S 1,311 2 1/2'' 490 12 1,850 1,800 2,600 1,820
KDAE-200S 1,764 2 1/2'' 558 15 1,900 1,850 2,800 2,100
KDAE-250S 2,048 3'' 750 18.5 2,800 1,600 2,800 2,320
KDAE-300S 2,804 3'' 1,052 25 2,800 1,600 2,650 3,200
KDAE-400S 3,517 4'' 1,430 32 3,200 2,500 2,950 5,050
KDAE-500S 4,486 4'' 1,688 40 3,300 2,550 2,900 5,100
KDAE-600S 5,130 6'' 2,448 60 3,400 2,500 3,200 7,300
KDAE-750S 6,930 6'' 2,864 70 3,600 2,800 3,900 9,500
KDAE-1550S 2,952 4'' 1,388 32 3,200 1,700 2,880 4,900
KDAE-3000S 5,400 6'' 2,376 60 3,600 2,500 3,165 7,200
KDAE-4100S 6,600 6'' 2,864 70 3,600 2,800 3,900 9,500
Features
● KDAE-S series are designed for reliable dew point -40℃(Atm) with
minimizing overheating of heater. Pre fi lter and after fi lter is designed in
skid type, easier piping work.
KCC Co., Ltd.
www.kccpr.com166 -
PNEUMATIC & HYDRAULIC KDAO seriesDesiccant Air Dryer (Oiless Type)
KDAO - 5
① ②
① SeriesKDAO Desiccant air dryer
② Size5, 7, 10, 20, 30, 40, 50, 75, 100, 130,
150, 170, 200, 250, 300, 400, 450, 500, 600, 750, 900
How to Order
KDAO series
Specifi cations
Model Flow Capacity(Nm3/hr)
In/Out Connection
Rc(PT)SOMA
(kg)Gel/2 Tower
(kg)Dimensions (mm)
Weight (kg)Width Length Height
KDAO-5 28 1/2''(S) 3 10 1,000 500 1,050 80
KDAO-7 55 1/2''(S) 6 22 1,000 550 1,300 175
KDAO-10 91 3/4''(S) 9 30 1,150 550 1,600 221
KDAO-20 173 1''(S) 18 62 1,100 700 1,900 300
KDAO-30 247 1''(S) 26 90 1,250 750 1,800 365
KDAO-40 356 1 1/2''(S) 29 100 1,600 750 1,900 442
KDAO-50 526 1 1/2''(S) 40 136 1,550 900 1,950 510
KDAO-75 651 1 1/2''(S) 55 176 1,600 900 2,450 700
KDAO-100 838 2''(S) 69 222 1,750 1,000 2,550 850
KDAO-130 975 2''(S) 80 258 1,850 1,000 2,350 895
KDAO-150 1,247 2''(S) 88 283 1,900 1,000 2,500 1,000
KDAO-170 1,511 2 1/2''(F) 121 392 2,000 1,050 2,650 1,260
KDAO-200 1,778 2 1/2''(F) 151 490 2,100 1,100 2,750 1,455
KDAO-250 2,160 3''(F) 172 546 2,100 1,200 2,550 1,505
KDAO-300 2,576 3''(F) 206 656 2,400 1,300 2,550 1,745
KDAO-400 3,089 3''(F) 287 910 2,600 1,400 2,750 2,380
KDAO-450 3,557 4''(F) 402 1,276 3,000 1,550 2,750 3,190
KDAO-500 4,058 4''(F) 451 1,430 3,000 1,600 2,900 3,500
KDAO-600 5,796 6''(F) 660 2,032 3,500 1,850 3,080 4,790
KDAO-750 7,371 6''(F) 773 2,380 3,900 2,150 3,100 5,670
KDAO-900 8,946 6''(F) 1,003 3,088 4,200 2,150 3,100 6,890
※ In/Out Connection : (S) Screw, (F) Flange
Features
● KDAO series is specially designed to eliminate oil mist. Heatless type or
heater type can be custom made depending on the dew point limit.
KCC Co., Ltd.
www.kccpr.com 176 -
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDAB seriesDesiccant Air Dryer (Heater Blower Type)
KDAB - 110
① ②
① SeriesKDAB Desiccant air dryer
② Size110, 130, 150, 200, 250, 280, 300, 400,
500, 600, 750, 1,200, 1,500, 2,000
How to Order
KDAB series
Specifi cations
Model Flow Capacity(Nm3/hr)
In/Out Connection
Rc(PT)
Electrical Power Gel/2 Tower (kg)
Dimensions (mm)Weight (kg)
Heater (kw) Blower (Hp) Width Length Height
KDAB-110 873 2'' 13 3 400 2,700 1,400 2,350 1,080
KDAB-130 970 2 1/2'' 13 3 480 2,700 1,400 2,400 1,320
KDAB-150 1,260 2 1/2'' 17 3 610 3,000 1,450 2,400 1,520
KDAB-200 1,520 3'' 20 5 730 3,300 1,500 2,400 1,770
KDAB-250 1,845 3'' 25 5 900 3,500 1,600 2,430 2,060
KDAB-280 2,180 3'' 32 5 1,080 3,550 1,700 2,470 2,450
KDAB-300 3,010 4'' 40 7.5 1,440 3,750 1,900 2,550 3,240
KDAB-400 3,490 4'' 46 7.5 1,700 3,850 2,000 2,550 3,720
KDAB-500 4,365 6'' 55 10 2,100 4,500 2,200 2,960 4,410
KDAB-600 5,820 6'' 80 10 2,800 4,800 2,200 3,000 5,390
KDAB-750 7,760 6'' 100 15 3,720 5,000 2,200 3,000 6,860
KDAB-1,200 9,800 8'' 130 20 4,600 6,200 2,400 3,100 11,270
KDAB-1,500 11,650 8'' 150 20 5,600 6,200 2,400 3,100 12,250
KDAB-2,000 15,550 10'' 180 25 6,970 7,500 2,500 3,300 13,900
Features
● KDAB is an energy saving product which minimized usage of compressed
air, and blower is used to inhale air for desiccant regeration. ● Dehumidifi cation time can be extended regarding to load.
Cycle Time■ Total Cycle : 8hr (Two Tower)■ Drying Cycle : 4hr (Per Tower)■ Regenaration Cycle : 4hr (Per Tower) - Heating : Using external air - Cooling : Using internal air
KCC Co., Ltd.
www.kccpr.com186 -
PNEUMATIC & HYDRAULIC
Desiccant Air Dryer (Non-Purge Type)
KDNP series
KDNP - 1100
① ②
① SeriesKDNP Desiccant air dryer (Non-purge type)
② Size1,100, 1,550, 2,100, 3,000, 4,100, 5,400,
6,000, 7,000, 9,000
How to Order
KDNP series
Specifi cations
Model Flow Capacity(Nm3/hr)
In/Out Connection(Flange)
Gel/2 Tower (kg)
Dimensions (mm)Weight (kg)
Width Length Height
KDNP-1100 1,950 3''(F) 858 2,600 1,750 2,500 2,500
KDNP-1550 2,952 4''(F) 1,388 2,800 1,900 2,800 3,000
KDNP-2100 3,702 5''(F) 1,640 3,200 2,200 2,900 4,100
KDNP-3000 5,400 6''(F) 2,376 4,000 2,400 3,000 5,500
KDNP-4100 6,600 6''(F) 2,510 4,550 2,400 3,100 7,500
KDNP-5400 9,498 8''(F) 3,100 5,200 3,000 3,300 10,800
KDNP-6000 10,500 8''(F) 4,590 5,600 3,100 3,500 12,500
KDNP-7000 12,000 8''(F) 5,264 5,800 3,100 3,500 13,800
KDNP-9000 15,000 10''(F) 6,580 6,500 3,500 3,610 17,100
Features
● KDNP Series regenerate desiccant using waste heat from compressor
(approx. 150℃). This energy saving air dryer have no compressed air
loss in flowing partial compressed air into dryer inlet after desiccant
regeneration● Dehumidifi cation time can be extended regarding to load.
Cycle time■ Total Cycle : 8hours (Two Tower)■ Drying Cycle : 4hours (Per Tower)■ Regenaration Cycle : 4hours (Per Tower) - Heating : Air compressor compress waste heat circulation - Cooling : Partial compressed air circulation
KCC Co., Ltd.
www.kccpr.com 196 -
PNEUMATIC & HYDRAULIC
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
KDH-C seriesAfter Cooler
KDH - 1C
① ②
① SeriesKDH After cooler
② Size1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C, 10C, 11C, 12C
How to Order
KDH-C series
Specifi cations
Model
Flow Capacity(Nm3/hr)
In/Out Connection
Rc(PT)
Max. pressure(kg/cm2)
Inlet Temp(℃)
Ambient Temp(℃)
Fan(Ø)
Fan Motor(W)
PowerDimensions (mm) Weight
(kg)60Hz 50Hz Width Length Height
KDH-1C 2.2 2.0 3/4"(S)
9.9 80℃↓ 38℃↓
250 16 AC 1Ph 220V60Hz 490 270 545 23
KDH-2C 3.3 3.0 1"(S) 300 66 AC 1Ph 220V 60Hz AC 3Ph 380V/440V
option
578 300 582 25
KDH-3C 5.2 4.7 1 1/2"(S) 350 100 738 300 692 35
KDH-4C 8.0 7.3 2" 350 100×2
AC 3Ph 220V/380V60Hz
1,070 350 765 69
KDH-5C 13.5 12.3 2 1/2"(F) 350X2 200×2 1,210 450 970 83
KDH-6C 17.5 15.9 3"(F) 400X2 0.2×2 1,385 460 990 100
KDH-7C 30 27.4 4"(F) 500X2 0.4×2 1,630 600 1,100 159
KDH-8C 41 37.4 4"(F) 550X2 0.4×2 1,850 600 1,220 180
KDH-9C 52 47.5 5"(F) 650X2 0.75×2 2,080 710 1,300 240
KDH-10C 80 73 5"(F) 500X4 0.4×2 2,200 650 1,850 280
KDH-11C 125 114 6"(F) 600X4 0.4×2 2,510 650 2,110 350
KDH-12C 155 142 8"(F) 650X4 0.75×2 2,610 750 2,110 420
※ In/Out Connection : (S) Screw, (F) Flange※ Coefficient of air flow capacity: Inlet temperature 38℃, ambient temperature 30~45℃, outlet temperature 30℃(△P 8℃), operating pressure 7kgf/cm2.
Features
● After cooler is an essential refrigeration supporting equipment which
is installed before air dryer to cool hot and high humidity air, support air
dryer to operate more effi ciency without malfunction.● Easy installment and maintenance without cooling water.● Low noise
KCC Co., Ltd.
www.kccpr.com206 -
PNEUMATIC & HYDRAULIC KDRC seriesChiller
KDRC - 1A
① ②
① SeriesKDRC Chiller
② Size1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 30A, 40A
How to Order
KDRC series
Specifi cations
Features
● Built-in high efficient and low noise compressor provide excellent
refrigeration. Accurate temperature control and wide range temperature
control is available by its digital temperature control devise.
ModelCooling Capacity(Kcal/hr)
Temp Range
(℃)
Ambient Temp (℃)
Cooling Water Pressure Range
kg/cm2(MPa)
Cooling Water Circulation
Volume Range(LPM)
Cooling Water Tank Capacity
(Liter)
Cooling Water Flow Rate
(LPM)Refrigerant
Compressor Capacity
(kw)
Circulation Pump
Capacity(kw)
KDRC-1A 2,800
5~30(±2℃) 0~45
1.0~2.5(0.1~0.25) 5~20 20 15
FreonR-22
0.75 0.35
KDRC-2A 5,600 1.5~3.5(0.15~0.35) 15~80 40 20 1.5 0.75
KDRC-3A 8,400 1.5~3.5(0.15~0.35) 15~80 60 20 2.25 0.75
KDRC-5A 14,000 3.0~6.0(0.3~0.6) 15~80 80 25 3.75 1.1
KDRC-7.5A 21,000 1.0~2.5(0.1~0.25) 30~130 100 25 5.63 1.1
KDRC-10A 28,000 1.5~3.5(0.15~0.35) 30~130 135 25 7.5 1.1
KDRC-15A 42,000 2.5~4.0(0.25~0.4) 100~210 165 32 11.25 2.2
KDRC-20A 56,000 3.0~5.0(0.3~0.5) 100~210 280 40 15 3
KDRC-30A 84,000 2.0~3.5(0.2~0.35) 160~430 350 50 22.5 4
KDRC-40A 112,000 3.5~5.5(0.35~0.55) 160~430 500 65 30 5.5
ModelCooling
Fan Motor Capacity (kw)
Power Consumption
(kw)Power Control circuit
powerDimensions (mm)
Width Length Height
KDRC-1A 0.1 1.2 AC 220V 1Ø 50/60Hz
AC 220V1Ø
470 760 870
KDRC-2A 0.2 2.45
AC 220V/380V/440V 3Ø 50/60Hz
580 960 1,050
KDRC-3A 0.2 3.2 580 960 1,050
KDRC-5A 0.4 5.25 660 1,060 1,130
KDRC-7.5A 0.75 7.48 760 1,100 1,345
KDRC-10A 0.4X2 9.4 760 1,600 1,350
KDRC-15A 0.4X2 14.95 945 1,750 1,595
KDRC-20A 0.75X2 19.5 1,050 2,100 1,768
KDRC-30A 0.75X3 28.75 1,050 2,900 1,921
KDRC-40A 0.75X3 37.75 1,200 3,800 2,140
※ Specifications might be change without notice. ※ Motor and other parts might be different depeding on production specifications.※ Cooling efficiency : Temperature control range 5~30℃, Ambiet temperature 0~45℃, operating pressure 7kgf/cm2(0.7MPa), operating dew point -50℃
KCC Co., Ltd.
www.kccpr.com 216 -
PNEUMATIC & HYDRAULIC
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
SEPREMIUM seriesOil-Water Separator
SEPREMIUM 10
① ②
① SeriesSEPRMIUM Oil-water separator
② Capacity10, 20, 30
How to Order
SEPREMIUM series
Specifi cations
Model Capacity(Nm3/min)
In/Out Connection Dimensions (mm)
In Out Width Length Height
SEPREMIUM 10 10 1/2" 1" 650 240 750
SEPREMIUM 20 20 1/2" 1" 780 305 900
SEPREMIUM 30 30 1/2" 1" 970 380 900
Features
● Oil-water separator is designed to eliminated oil after oil and
water is being separated effi ciently.● Easy installment, easy maintenance● Condensed water discharged by intelegent drain
Indicator In/Out Connection
KCC Co., Ltd.
www.kccpr.com226 -
PNEUMATIC & HYDRAULIC
Features
● Service tank is assential at the outlet of compressor for provide
air in uniform pressure without pulsation.● Capacity of tank is determined by the usage of compressor
such as capacity, working pressure and etc.● Tank is corresponding with occupation safety and health acts,
user shall use the product after inspection by occupation safety
and heatlh admisistration.● The whole tank's design and performance is after inspection of
occupation safety and heatlh admisistration.
KDRT seriesReceiver Tank
KDRT - 500-A
① ②
① SeriesKDRT Receiver tank
② Size500-A, 800-A, 1,000-A, 1,500-A, 2,000-A, 3,000-A,
5,000-A, 8,000-A, 10K, 20K, 30K, 56K
How to Order
KDRT series
Specifi cations
How to Select Receiver Tank
Dimensions
ModelFlow
Capacity (m3)
In/Out Connection
Dimensions (mm) Weight (kg)D H
KDRT-500-A 0.5 PT 50A 660 1,733 184
KDRT-800-A 0.8 PT 50A 760 2,088 306
KDRT-1,000-A 1.0 PT 50A 850 2,132 392
KDRT-1,500-A 1.5 PT 50A 946 2,486 521
KDRT-2,000-A 2.0 FL 80A 1,110 2,567 764
KDRT-3,000-A 3.0 FL 80A 1,310 2,666 993
KDRT-5,000-A 5.0 FL 100A 1,485 3,361 1,628
KDRT-8,000-A 8.0 FL 125A 1,845 3,539 2,528
KDRT-10K 10.0 FL 150A 2,025 3,648 3,020
KDRT-20K 20.0 FL 200A 2,400 5,200 5,500
KDRT-30K 30.0 FL 250A 2,800 5,950 6,500
KDRT-56K 56.0 FL 350A 2,620 11,232 19,000
DDH
■ Air receiver tank capacity formula
V Volume of the receiver tank (m3)t Time allowed for pressure drop to occur (min)
Q1 Air demand by compressor (m3)Q2 Surplus air volume from compressor (m3)P1 Free air pressure (kgf/cm2)P2 Receiver tank proof pressure (kgf/cm2)P3 Compressor working pressure (kgf/cm2)
V = {P1×(Q1-Q2)×t} / (P2-P3)
■ Air discharge by compressor is 550 ℓ/min and the pressure of discharged air is 8.5kgf/cm2,what is the size of receiver should be selected if the compressor eject 1500ℓ air in 40 seconds?
P1 1.03323 kgf/cm2 P2 9.53323kgf/cm2(a)Q1 1.5m3 P3 6.03323kgf/cm2(a)Q2 0.55m3×40sec/60sec≒0.37m3 t 0.67min(40sec)
V = {1.0332×(1.5-0.37)×0.67} / (9.5332-6.0332)
= 0.223(m3)≒230ℓ= 0.23m3
Install a receiver tank which the volume is greater than 0.23m3
� Operating pressure: 9.9kgf/cm2 (Custom made of other specification is available upon customer request)
KCC Co., Ltd.
www.kccpr.com 236 -
PNEUMATIC & HYDRAULIC
Air Dryer
ReferenceData
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
KDHAD seriesAuto Drain Trap
KDHAD - 125
① ②
① SeriesKDHAD Auto drain trap
② In/Out Connection125 Rc(PT) 1/2300 M30
How to Order
KDHAD series
Specifi cations Dimensions
Model KDHAD-125 KDHAD-300
In/Out Connection Rc(PT)1/2 M30
Operation Pressure 1.5~9.9kgf/cm2 (0.15~0.99MPa)
Max. Pressure 13kgf/cm2 (1.3MPa)
Inlet Temp ℃ 60℃
Application Filter (20A~150A), Tank
KDHAD-125KDHAD-300
Applications
● Automatic discharge condensate water in the
compressed air of air compressor, receiver tank,
water cooler, air dryer and etc.
163
93
Ø6
Inlet port
KCC Co., Ltd.
www.kccpr.com246 -
PNEUMATIC & HYDRAULIC
EZ-1 series
Timer Valve
Operating interval 0.5-45 min, Adjustable Operation 2/2 Way, direct acting
Valve open/close time 0.5-10 sec, Adjustable In/Out port 1/2'' BSP
Manual switch Micro switch Operating pressure 0~16.0kgf/cm2(0~1.6MPa)
Voltage 230 VAC/DC, 50/60Hz (±10%) Ambient Temperature 2℃ ~ 55℃
Current consumption Max. 7mA Seal material FPM (Viton)
Operation temperature -40℃ ~ 60℃ Fluid temperature Max. 90˚ C
Protect class IP 65 Valve material Brass
Material ABS plastic FR grade UL94Vo Insulation class Grade F
Connection DIN 43650A ISO 440/6952 Protect class IP 65
Display lamp1 LED (Yellow) Display ON Orifi ce 4.0 mm
1 LED (Yellow) Display OFF Voltage 230VAC 50/60 Hz (±10%)
EZ-1 series
Electrical Trap(Timer Valve)
EZ-1 series
Specifi cations
Features
● Easy installment
● Large orifi ce (4mm) prevent blockage
● Seal material : FPM (Viton)
● Valve connection port : 1/2'' BSP or NPT
● Standard opeartig pressure: 0~1.6MPa
Dimensions
KCC Co., Ltd.
www.kccpr.com 256 -
Air Dryer
Reference data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
KDXF 320 -
① ② ③
① SeriesKDXF High performance air fi lter
② Type370 Main Filter(20㎛)320 Pre Filter(3㎛)310 Line Filter(1㎛)130 Coalescent Filter(0.01㎛)150 Adsorbent Filter(0.01ppm)
③ In/Out Connection15A Rc(PT)1/2 100A Rc(PT)420A Rc(PT)3/4 125A Rc(PT)525A Rc(PT)1 150A Rc(PT)640A Rc(PT)1 1/2 200A Rc(PT)850A Rc(PT)2 250A Rc(PT)1065A Rc(PT)2 1/2 300A Rc(PT)1280A Rc(PT)3
How to Order
KDXF series
Specifi cations
ModelIn/Out
ConnectionRc(PT)
Flow Capacity (Nm3/min) Dimensions
Weight (kg)
Main Filter(20㎛)
Pre Filter(3㎛)
Line Filter(1㎛)
Coalescent Filter
(0.01㎛)
Adsorbent Filter
(0.01ppm)Width(mm)
High(mm)
370 320 310 130 150KDXF 15A 1/2'' (S) 2.2 1.8 1.2 1.0 1.0 88 278 1.25
KDXF 20A 3/4'' (S) 5.7 3.5 2.8 1.9 1.9 89 500 3.5
KDXF 25A 1'' (S) 8.0 5.7 5.0 3.4 3.4 100 600 4.5
KDXF 40A 1 1/2'' (S) 17.0 14.0 11.0 10.0 10.0 138 835 13.7
KDXF 50A 2'' (S) 29.0 25.0 22.0 14.0 14.0 148 900 21
KDXF 65A 2 1/2'' (F) 58.0 50.0 48.0 28.0 28.0 570 1,210 85
KDXF 80A 3'' (F) 88.0 75.0 72.0 42.0 42.0 570 1,220 95
KDXF 100A 4'' (F) 145.0 125.0 110.0 70.0 70.0 620 1,305 125
KDXF 125A 5'' (F) 174.0 150.0 132.0 84.0 84.0 620 1,305 140
KDXF 150A 6'' (F) 282.0 221.0 176.0 112.0 112.0 812 2,060 250
KDXF 200A 8'' (F) 447.0 331.0 308.0 196.0 196.0 1,000 2,325 340
KDXF 250A 10'' (F) 733.0 555.0 528.0 336.0 336.0 1,200 2,130 400
KDXF 300A 12'' (F) 1,103.0 850.0 792.0 504.0 504.0 1,450 2,130 450
※ For port size : (S) : Screw type, (F) : Flange type.
Features
● Excellent in fi ltering solid material and moisture.● Filter with HEPA absorbent can effi ciently eliminate fi ne particles and
blazed and carbonized particles from air compressor. ● Made of stainess steel, long service life.
Element Model Quantity
KDXE-15A 1
KDXE-20A 1
KDXE-25A 1
KDXE-40A 1
KDXE-50A 1
KDXE-65A 2 (KDXE-50A)
KDXE-80A 3 (KDXE-50A)
KDXE-100A 5 (KDXE-50A)
KDXE-125A 6 (KDXE-50A)
KDXE-150A 11 (KDXE-50A)
KDXE-200A 14 (KDXE-50A)
KDXE-250A 24 (KDXE-50A)
KDXE-300A 36 (KDXE-50A)
Element Quantity
KCC Co., Ltd.
www.kccpr.com266 -
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF15A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D
Rc(PT)E
Rc(PT) Element
370 2.2 89 278 262 1/2'' 1/4'' Main Element (40μ)
320 1.8 89 278 262 1/2'' 1/4'' Pre Element (5μ)
310 1.2 89 278 262 1/2'' 1/4'' Line Element (1μ)
130 1.0 89 278 262 1/2'' 1/4'' Coalescent Element (0.01μ)
150 1.0 89 278 262 1/2'' 1/4'' Adsorbent Element (0.01ppm)
No. Element
1 UPPER HOUSING
2 ELEMENT
3 CAP
4 FLOAT
5 NUT
6 DOWN HOUSING
7 STUD BOLT
Structure & Dimensions (KDXF20A-370, 320, 310, 130)
Model Air volume(Nm3/hr) A B C D
Rc(PT)E
Rc(PT) Element
370 5.7 112 490 464 3/4'' 1/4'' Main Element (40μ)
320 3.5 112 490 464 3/4' 1/4'' Pre Element (5μ)
310 2.8 112 490 464 3/4' 1/4'' Line Element (1μ)
130 1.9 112 490 464 3/4' 1/4'' Coalescent Element (0.01μ)
150 1.9 112 490 464 3/4' 1/4'' Coalescent Element (0.01ppm)
No. Element
1 UPPER HOUSING
2 MIDDLE HOUSING
3 ELEMENT COVER CAP
4 DOWN HOUSING
5 AUTO TRAP (PT 1/2'')
6 STUD BOLT
7 ELEMENT
8 CAP
9 BALL VALVE
①
⑦
②
⑥③④
⑤
①
②
⑥③④
⑤
①②⑥⑦③
④⑧
⑤⑨
①②
④
⑤
KCC Co., Ltd.
www.kccpr.com 276 -
Air Dryer
Reference data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF25A-370, 320, 310, 130)
No. Element
1 UPPER HOUSING
2 MIDDLE HOUSING
3 ELEMENT COVER CAP
4 DOWN HOUSING
5 AUTO TRAP (PT 1/2'')
6 STUD BOLT
7 ELEMENT
8 CAP
9 BALL VALVE
Model Air volume(Nm3/hr) A B C D
Rc(PT)E
Rc(PT) Element
370 8.0 112 700 674 1'' 1/4'' Main Element (40μ)
320 5.7 112 700 674 1'' 1/4' Pre Element (5μ)
310 5.0 112 700 674 1'' 1/4' Line Element (1μ)
130 3.4 112 700 674 1'' 1/4'Coalescent
Element (0.01μ)
150 3.4 112 700 674 1'' 1/4'Coalescent
Element (0.01ppm)
Structure & Dimensions (KDXF40A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D
Rc(PT)E
Rc(PT) Element
370 29 164 930 892 1/2'' 1/4'' Main Element (40μ)
320 25 164 930 892 1/2'' 1/4'' Pre Element (5μ)
310 22 164 930 892 1/2'' 1/4'' Line Element (1μ)
130 14 164 930 892 1/2'' 1/4''Coalescent
Element (0.01μ)
150 14 164 930 892 1/2'' 1/4'' Adsorbent Element (0.01ppm)
No. Element
1 UPPER HOUSING
2 ELEMENT
3 DOWN HOUSING
4 WRENCH BOLT
5 AUTO TRAP (PT1/2'')
6 DICFLACTAR
7 STUD BOLT
8 ELEMENT COVER CAP
9 CAP
①②⑥⑦
③⑧④
⑤
⑨
①
②
⑨
⑤
④
①⑥④⑦②⑧⑨③⑤
①⑥④⑦②⑧⑨③⑤
KCC Co., Ltd.
www.kccpr.com286 -
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF50A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D
Rc(PT)E
Rc(PT) Element
370 29 181 1180 1141 2'' 1/4'' Main Element (40μ)
320 25 181 1180 1141 2'' 1/4' Pre Element (5μ)
310 22 181 1180 1141 2'' 1/4' Line Element (1μ)
130 14 181 1180 1141 2'' 1/4'Coalescent
Element (0.01μ)
150 14 181 1180 1141 2'' 1/4'Coalescent
Element (0.01ppm)
No. Element
1 UPPER HOUSING
2 ELEMENT
3 DOWN HOUSING
4 WRENCH BOLT
5 AUTO TRAP (PT 1/2'')
6 DICFLACTAR
7 STUD BOLT
8 ELEMENT COVER CAP
9 CAP
Structure & Dimensions (KDXF65A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D E
Rc(PT) F G H Element
370 58.0 570 1,210 860 140 1/2'' 70 70 (F)2 1/2 Main Element (40μ)
320 50.0 570 1,210 860 140 1/2'' 70 70 (F)2 1/2 Pre Element (5μ)
310 48.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Line Element (1μ)
130 28.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Coalescent Element (0.01μ)
150 28.0 570 1,110 760 140 1/2'' 70 70 (F)2 1/2 Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 10''
3 IN/OUTLET FLANGE 2 1/2''
4 PRESSURE GAUGE (SOCKET 1/4'')
5 PIPE 10''
6 ELEMENT
7 BOLT (M22×75)
8 FLANGE ANSI 150# SO.RF(10'')
9 NUT (M22)
10 DRAIN NOZZLE (SOCKET 1/2'')
①⑥④⑦②⑧⑨③⑤
①⑥④⑦②⑧⑨③
⑤
①②③
④
⑤
⑥
⑦⑧⑨⑩
①②③
④
⑤
⑥
⑦⑧⑨⑩
KCC Co., Ltd.
www.kccpr.com 296 -
Air Dryer
Reference data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF80A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D E
Rc(PT) F G H Element
370 88.0 570 1,220 860 140 1/2'' 70 70 (F)3'' Main Element (40μ)
320 75.0 570 1,220 860 140 1/2'' 70 70 (F)3'' Pre Element (5μ)
310 72.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Line Element (1μ)
130 42.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Coalescent Element (0.01μ)
150 42.0 570 1,120 760 140 1/2'' 70 70 (F)3'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 10''
3 IN/OUTLET FLANGE 3''
4 PRESSURE GAUGE (SOCKET 1/4'')
5 PIPE 10''
6 ELEMENT
7 BOLT (M22×75)
8 FLANGE ANSI 150# SO.RF(10'')
9 NUT (M22)
10 DRAIN NOZZLE(SOCKET 1/2'')
Structure & Dimensions (KDXF100A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D E
Rc(PT) F G H Element
370 145.0 620 1,305 860 140 1/2'' 70 70 (F)4'' Main Element (40μ)
320 125.0 620 1,305 860 140 1/2'' 70 70 (F)4'' Pre Element (5μ)
310 110.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Line Element (1μ)
130 70.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Coalescent Element (0.01μ)
150 70.0 620 1,205 760 140 1/2'' 70 70 (F)4'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 12''
3 IN/OUTLET FLANGE 4''
4 PRESSURE GAUGE (SOCKET 1/4'')
5 PIPE 12''
6 ELEMENT
7 BOLT (M22×75)
8 FLANGE (12'')
9 NUT (M22)
10 DRAIN NOZZLE (SOCKET 1/2'')
①②
③
④
⑤
⑥
⑦⑧⑨⑩
①②
③
④
⑤
⑥
⑦⑧⑨⑩
①②
③
④
⑤
⑥
⑦⑧⑨⑩
①②
③
④
⑤
⑥
⑦⑧⑨⑩
KCC Co., Ltd.
www.kccpr.com306 -
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF125A-370, 320, 310, 130, 150)
Model Air volume(Nm3/hr) A B C D E
Rc(PT) F G H Element
370 174.0 620 1,306 860 140 1/2'' 70 70 (F)5'' Main Element (40μ)
320 150.0 620 1,305 860 140 1/2'' 70 70 (F)5'' Pre Element (5μ)
310 132.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Line Element (1μ)
130 84.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Coalescent Element (0.01μ)
150 84.0 620 1,205 760 140 1/2'' 70 70 (F)5'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 12''
3 IN/OUTLET FLANGE 5''
4 PRESSURE GAUGE (SOCKET 1/4'')
5 PIPE 12''
6 ELEMENT
7 BOLT (M22×75)
8 FLANGE (12'')
9 NUT (M22)
10 DRAIN NOZZLE (SOCKET 1/2'')
Structure & Dimensions (KDXF150A-370, 320, 310)
Model Air volume(Nm3/hr) A B C D E F G H Element
370 282.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Main Element (40μ)
320 221.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Pre Element (5μ)
310 176.0 812 2,059.8 970 850 406.4 100 1/4'' (F) 6'' Line Element (1μ)
No. Element
1 EYE BOLT 3/4''
2 CAP 16''
3 IN/OUTLET FLANGE 6''
4 PRESSURE GAUGE NOZZLE1/4''
5 PIPE 16''
6 ELEMENT
7 BOLT (B24×80)
8 FLANGE (16'')
9 NUT (M24)
10 DRAIN NOZZLE (1/2'')
①②③
④
⑤
⑥
⑦⑧⑨⑩
①②
③
④
⑤
⑥
⑦⑧⑨⑩
①②③
④
⑤
⑥
⑦⑧⑨⑩
①②③
④
⑤
⑥
⑦⑧⑨⑩
KCC Co., Ltd.
www.kccpr.com 316 -
Air Dryer
Reference data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF150A-130, 150)
Model Air volume(Nm3/hr) A B C D E F G H Element
130 112.0 812 2,059.8 970 850 406.4 100 1/4'' (F)6'' Coalescent Element (0.01μ)
150 112.0 812 2,059.8 970 850 406.4 100 1/4'' (F)6'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 16''
3 IN/OUTLET FLANGE 6''
4 PRESSURE GAUGE 1/4''
5 PIPE 16''
6 ELEMENT
7 BOLT (B24×80)
8 FLANGE (16'')
9 NUT (M22)
10 DRAIN NOZZLE (SOCKET 1/2'')
Structure & Dimensions (KDXF200A-370, 320)
Model Air volume(Nm3/hr) A B C D E F G H Element
370 447.0 1,000 2,326 1,327 673 508 130 1/4'' (F)8'' Main Element (40μ)
320 331.0 1,000 2,626 1,327 673 508 130 1/4'' (F)8'' Pre Element (5μ)
No. Element
1 EYE BOLT 3/4''
2 CAP 20''
3 IN/OUTLET FLANGE 8''
4 PRESSURE GAUGE NOZZLE 1/4''
5 PIPE 20''
6 ELEMENT
7 BOLT (B24×95)
8 FLANGE (20'')
9 NUT (M24)
10 DRAIN NOZZLE 1/2''
①②③
④
⑤
⑥
⑦⑧⑨
⑩
①②③
④
⑤
⑥
⑦⑧⑨
⑩
KCC Co., Ltd.
www.kccpr.com326 -
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF200A-310, 130, 150)
Model Air volume(Nm3/hr) A B C D E F G H Element
310 308.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Line Element (1μ)
130 196.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Coalescent Element (0.01μ)
150 196.0 1000 2326 1327 673 508 130 1/4'' (F)8'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 20''
3 IN/OUTLET FLANGE 8''
4 PRESSURE GAUGE NOZZLE 1/4''
5 PIPE 20''
6 ELEMENT
7 BOLT (B24×95)
8 FLANGE (20'')
9 NUT (M24)
10 DRAIN NOZZLE 1/2''
Structure & Dimensions (KDXF250A-370, 320)
Model Air volume(Nm3/hr) A B C D E F G H Element
370 733.0 1,200 2,130 990 745 609.6 80 1/4'' (F)10'' Main Element (40μ)
320 555.0 1,200 2,130 990 745 609.6 80 1/4'' (F)10'' Pre Element (5μ)
No. Element
1 EYE BOLT 3/4''
2 CAP 24''
3 IN/OUTLET FLANGE 10''
4 PRESSURE GAUGE NOZZLE1/4''
5 PIPE 24''
6 ELEMENT
7 BOLT (B24×80)
8 FLANGE (24'')
9 NUT (M30)
10 DRAIN NOZZLE (1/2'')
①②③
④
⑤
⑥
⑦⑧⑨
⑩
①②③
④
⑤
⑥
⑦
⑧⑨
⑩
KCC Co., Ltd.
www.kccpr.com 336 -
Air Dryer
Reference data
KDHR
KDHR-W
KDHT
KDAH
KDAE
KDAE-S
KDAO
KDAB
KDNP
KDH-C
KDRC
SEPREMIUM
KDRT
KDHAD
EZ-1
KDXF
KDXE
PNEUMATIC & HYDRAULIC KDXF seriesHigh Performance Air Filter
Structure & Dimensions (KDXF250A-310)
Model Air volume(Nm3/hr) A B C D E F G H Element
310 528.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Line Element (1μ)
No. Element
1 EYE BOLT 3/4''
2 CAP 26''
3 IN/OUTLET FLANGE 10''
4 PRESSURE GAUGE 1/4''
5 PIPE 26''
6 ELEMENT
7 BOLT (B24×80)
8 FLANGE (26'')
9 NUT (M30)
10 DRAIN NOZZLE 1/2'')
Structure & Dimensions (KDXF250A-130, 150)
Model Air volume(Nm3/hr) A B C D E F G H Element
130 336.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Coalescent Element (0.01μ)
150 336.0 1,200 2,130 990 745 660.4 80 1/4'' (F)10'' Adsorbent Element (0.01ppm)
No. Element
1 EYE BOLT 3/4''
2 CAP 26''
3 IN/OUTLET FLANGE 10''
4 PRESSURE GAUGE NOZZLE1/4''
5 PIPE 26''
6 ELEMENT
7 BOLT (B24×80)
8 FLANGE (246')
9 NUT (M30)
10 DRAIN NOZZLE (1/2'')
①②③
④
⑤
⑥
⑦
⑧
⑨⑩
①②③
④
⑤
⑥
⑦⑧⑨⑩
KCC Co., Ltd.
www.kccpr.com346 -
PNEUMATIC & HYDRAULIC KDXE seriesFilter Element
KDXE 370 - 15A
① ② ③
How to Order
KDXE series
Specifi cations
KDXE370KDXE320 KDXE310 KDXE130 KDXE150
ModelMAIN PRE LINE COALESCENT ADSORBENT
KDXE-370, 320 KDXE-310 KDXE-130 KDXE-150
Structure
Filtering 100% remove solid substance above 20㎛
100% remove solid substance above1㎛
100% remove solid substance above0.1㎛
100% remove solid substance above0.01㎛
Material Sintered resin Hepa Hepa/Polyester Hepa/Polyester/Active carbon paper
Application
Eliminate liquid, oil, rust debris and any particle larger than 3㎛. Most commonly used.
For shear tools or general air tools.
Eliminate 99% of spray paint and oil vapor. Does not remove smell.
Strengthened elimination of oil vapor. For precision electronics, semiconductor, pharmaceutical manufacturing process.
Installation place
Installed at the production main line or before refrigerated air dryer and filter (KDXE-310m 130, 150).Essential for long piping line to prevent flow in of condensate water.
Installed at the end of production line or on a desiccant dryer. And, by installed it before filter KDXE-130 or KDXE-150 will extend service life of the filter.
Installed at the part where oil and water need to be totaly eliminated. Install it before desiccant air dryer will strengthen dehumidification efficiency and prolong the life of the adsorbent.
It is the filter installed at the end of the line to eliminate solid object which is greater than 0.01㎛. An essential equipment for the site requires clear compressed air.
Maintenance & replacement
Clean element with neutral cleaser when pressure difference become 0.07MPa (0.7kg/cm2). Do not use gasoline or thinner.
Replace a new cartridge if the differential pressure become 0.5kg/cm2(0.05MPa) or above.
Features
● One-touch attaching type element allows easy replacement. ● Various media type element to eliminate corpuscles, oil
mist, moisture, gas and etc.
One-touch attaching type element
Type 15A 20A 25A 40A 50A
Dimensions (mm) 48×105 48×150 48×200 78×450 78×460
Dimensions
① SeriesKDXE Filter element
② Type370 Main Filter(20㎛)320 Pre Filter(3㎛)310 Line Filter(1㎛)130 Coalescent Filter(0.01㎛)150 Adsorbent Filter(0.01ppm)
③ Applicable Dimensions15A For 1/2 20A For 3/425A For 140A For 1 1/250A For 2