1 Exam Prep SMACNA Architectural Sheet Metal 1 1 Exam Prep SMACNA Architectural Sheet Metal Questions 1. Which of the following is not an advantage of terne? A Lightweight B High expansion rate C Low expansion rate D Durable 2. Downspouts should be constructed with conductor heads every___________. A 40 feet B 50 feet C 25 feet D 30 feet 3. To limit effects of thermal expansion in gutters the maximum length of gutter should be_________. A 40 feet B 50 feet C 30 feet D 25 feet 4. The rule of 50 feet maximum length for gutters is satisfied by which of the following? A Using a pull tape B Measuring twice C Subcontracting the gutter work D Locating 2 gutter outlets at the same anchor point 5. The minimum length of the outlet tube should be how many inches total? A 4 B 4 3/8 C 6 D 12 6. A corrugated round aluminum downspout shall be a minimum_______ A. .025 inches B 5 feet C 40 feet D .032 inches
Transcript
  • 1 Exam Prep – SMACNA Architectural Sheet Metal 1

    1 Exam Prep

    SMACNA Architectural Sheet Metal Questions

    1. Which of the following is not an advantage of terne?

    A Lightweight

    B High expansion rate

    C Low expansion rate

    D Durable

    2. Downspouts should be constructed with conductor heads every___________.

    A 40 feet

    B 50 feet

    C 25 feet

    D 30 feet

    3. To limit effects of thermal expansion in gutters the maximum length of gutter should be_________.

    A 40 feet

    B 50 feet

    C 30 feet

    D 25 feet

    4. The rule of 50 feet maximum length for gutters is satisfied by which of the following?

    A Using a pull tape

    B Measuring twice

    C Subcontracting the gutter work

    D Locating 2 gutter outlets at the same anchor point

    5. The minimum length of the outlet tube should be how many inches total?

    A 4

    B 4 3/8

    C 6

    D 12

    6. A corrugated round aluminum downspout shall be a minimum_______

    A. .025 inches B 5 feet

    C 40 feet

    D .032 inches

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 2

    7. The minimum flange width for outlets is__________

    A 1/4 inch

    B 1/2 inch

    C 3/8 inch

    D 3/4 inch

    8. Metal counter-flashing should cover how many inches of the base flashing?

    A 12

    B 10

    C 8

    D 4

    9. The reglet should be attached__________

    A After the concrete is poured

    B Before the concrete sets

    C During the progress of the work

    D Before the concrete is poured

    10. Reglets should be fastened___________

    A 24 inches on center

    B Using termination bars

    C 18 inches on center

    D 12 inches on center

    11. Flashing is generally formed in__________

    A 10 foot sections

    B 12 foot sections

    C 20 foot sections

    D On the jobsite

    12. Flashing should be lapped__________

    A 8 inches in the opposite direction of flow

    B 10 inches in the direction of flow

    C 8 inches in the direction of flow

    D 12 inches in the direction of flow

    13. The minimum gauge stainless steel to be used for roof penetration flashing is___________

    A 16

    B 24

    C 22

    D 26

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 3

    14. No counter flashing should be more than how many brick high?

    A 2

    B 3

    C 4

    D 6

    15. Base flashing should extend up the wall a minimum of how many inches?

    A 4

    B 6

    C 8

    D 10

    16. Saddle flashing must be flanged how many inches?

    A 4

    B 6

    C 8

    D 10

    17. Pans are installed with cleats double nailed with one cleat per_________ square feet.

    A 6

    B 4

    C 2

    D 1

    18. Stainless steel corner guards are fabricated using a minimum gauge of__________

    A 26

    B 24

    C 20

    D 18

    19. Which of the following is not allowed for aluminum seams?

    A Rivets

    B Sealants

    C Welding

    D Soldering

    20. Some areas of air leakage are?

    A Windows, doors and vent stacks

    B Seams, roof edges and wall outlets

    C Flashings, vent stacks and chimneys

    D Seams, roof edges and flashings

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 4

    21. Corrugated round downspouts with 25.97 square inches of area have a nominal size

    of___________ inches.

    A 3

    B 6

    C 8

    D 10

    22. The maximum length of gutter between ends is_________ feet.

    A 50

    B 100

    C 10

    D 75

    23. The minimum gauge for aluminum gutter girthed at 10" is____________

    A .040

    B 1.032

    C .032

    D .051

    24. Gutter straps when used to girth 22" and when made of aluminum should be____________

    inches.

    A 1/2 x 1

    B 1/4 x 2

    C 1/2 x 2

    D 1/4 x 1 ½

    25. The minimum recommended gauge for counter flashing is ___________inches when applying

    aluminum.

    A 16 oz

    B 26 ga

    C .032

    D .050

    26. 24 gauge steel gravel stop facia with a 13" vertical design requires a "J" design of_________

    A 221

    B 5 or higher

    C 4

    D 2

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 5

    27. Sixteen ounce copper has an approximate thickness of___________

    A .0243

    B .0216

    C .0202

    D 4"

    28. Sheet metal 16 gauge galvanized is__________ inches thick.

    A .06

    B .0538

    C .05

    D .0198

    29. Aluminum has a tensile strength of___________ P.S.I.

    A 15,000

    B 17,000

    C 22,000

    D 24,000

    30. Corrugated round downspouts with 25.97 square inches of area have a nominal size

    of___________ inches.

    A 3

    B 6

    C 8

    D 10

    31. The maximum length of gutter between ends is_________ feet.

    A 50

    B 100

    C 10

    D 75

    32. The minimum gauge for aluminum gutter girthed at 10" is____________

    A .040

    B 1.032

    C .032

    D .051

    33. Gutter straps when used to girth 22" and when made of aluminum should be____________

    inches.

    A 1/2 x 1

    B 1/4 x 2

    C 1/2 x 2

    D 1/4 x 1 ½

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 6

    34. The minimum recommended gauge for counter flashing is ___________inches when applying

    aluminum.

    A 16 oz

    B 26 ga

    C .032

    D .050

    35. 24 gauge steel gravel stop facia with a 13" vertical design requires a "J" design of_________

    A 221

    B 5 or higher

    C 4

    D 2

    36. Sixteen ounce copper has an approximate thickness of___________

    A .0243

    B .0216

    C .0202

    D 4"

    37. Sheet metal 16 gauge galvanized is__________ inches thick.

    A .06

    B .0538

    C .05

    D .0198

    38. Aluminum has a tensile strength of___________ P.S.I.

    A 15,000

    B 17,000

    C 22,000

    D 24,000 39. The design area for a pitched roof with five inches per running foot measurement is________

    A 1.05

    B 4.20

    C 1.00

    D 5.25

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 7

    40. According to the Architectural Sheet Metal Manual, a plain round standard downspout with an area of

    12.57 square inches requires a nominal size of______________ inches.

    A 3

    B 4

    C 5

    D 6

    41. The recommended gage for a galvanized gutter with a girth of 20 inches is_____________

    A 19

    B 21

    C 23

    D 24

    42. When installing gutters on a sloped roof and the facia board is less than ___________ inches thick, the

    spikes must be driven into the rafter ends.

    A 1

    B 2

    C 3

    D 4

    43. Splash pans require a back height_____________ inches greater than the downspout.

    A 1

    B 2

    C 3

    D 4

    44. When using formed gravel stop facia, ____________corners are not recommended.

    A Glued

    B Formed

    C Seam locked

    D Welded

    45. Whenever gravel stop is installed with quarter inch openings between the sections, the opening should be

    covered by a_______ inch cover plate formed to the profile of the gravel stop.

    A 4

    B 6

    C 8

    D 9

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 8

    46. A reglet is defined as a cut in the masonry joint to a depth of at least __________ inches.

    A 1/2

    B 3/4

    C 1 1/4

    D 1 ½

    47. When reglets are not used as counter flashing systems, masonry anchors should be installed how many

    inches on center?

    A 18

    B 24

    C 36

    D 16

    48. Closed valley flashing should be how wide for a 5 in 12 roof?

    A 18

    B 24

    C 36

    D 16

    49. When installing valley flashing, valley flashings should be lapped _________inches in the?

    A 8, heading of the flow

    B 8, following the head of the flow

    C 8, direction of the flow

    D 6, direction of the flow

    50. Hip and ridge flashing is generally formed in__________ foot lengths and is lapped a minimum of how

    many inches?

    A 12, 6

    B 10, 8

    C 12, 4

    D 10, 4

    51. The ridge cap should extend onto the shingled roof a minimum of how many inches?

    A 2

    B 4

    C 6

    D 8

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 9

    52. Roll pans of up to___________ feet might be used.

    A 30

    B 20

    C 10

    D 5

    53. The recommended gage for galvanized metal counter flashing is what galvanized steel?

    A 22 gauge

    B 24 gauge

    C 26 gauge

    D 29 gauge

    54. Standing seam metal roofs with 23 34-inch wide sheets require a minimum seam height

    of ___________inches.

    A 3/4

    B 7/8

    C 1

    D 1 ½

    55. When installing aluminum, an important fact to remember is the joints cannot be__________

    A Riveted

    B Welded

    C Soldered

    D Sealed

    56. Corner guards are fabricated of __________

    A Galvanized metal

    B Terne

    C Stainless steel

    D Copper

    57. The "E" value for aluminum 75 degrees Fahrenheit 10 feet long is __________ inches.

    A 3/16

    B 3/4

    C 11/16

    D 1/ 4

    58. Twenty gauge galvanized metal weighs how many pounds per square foot?

    A 1.9

    B 2.1

    C 3.9

    D 1.7

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 10

    59. Whenever gravel stop is installed with quarter inch openings between the sections, the

    opening should be covered by a _______ inch cover plate formed to the profile of the gravel stop.

    A 4

    B 6

    C 8

    D 9

    60. Formed gravel stop should not be______________

    A Plated

    B Soldered

    C Formed

    D Sealed

    61. The elevation difference in rectangular gutters should be __________ inch.

    A 1

    B 1 /4

    C 1/12

    D 1 /2

    62. The recommended gage for copper gutters girthed 24 inches is____________

    A 22

    B 20

    C 26

    D 29

    63. Continuous cleats should not exceed how many feet?

    A 8

    B 10

    C 12

    D 2

    64. Corrugated rectangular downspouts with 18.75 square inches of area have a nominal size of __________

    inches.

    A 3

    B 5

    C 8

    D 10

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 11

    65. Maximum roof area for 5" gutters on sloped roofs with 1/8 inch per foot of slope is_________

    A 2,040

    B 5,000

    C 3,520

    D 2,880

    66. The open portion of a valley for a slate roof is how many inches?

    A 3

    B 4

    C 5

    D 6

    67. The maximum length of a gutter between expansion joints is _____________

    A 50 feet

    B 100 feet

    C 75 feet

    D 25 feet

    68. A six-inch downspout requires a minimum splash pan back height of __________

    A 6 inches

    B 8 inches

    C 10 inches

    D 12 inches

    69. The recommended gage for galvanized steel when used for reglet installation is __________

    A .0220 inches

    B .0179 inches

    C .0299 inches

    D .0320 inches

    70. Pans installed with cleats should be ______________

    A Double nailed

    B Double nailed every 24 inches

    C Single nailed every 12 inches

    D Single nailed every 24 inches

    71. Metal counter flashing is installed so that a minimum of how many inches of the base flashing is covered?

    A 3

    B 4

    C 6

    D 8

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 12

    72. The pan width for a .018 stainless steel standing seam roof with a seam height of 1 ½ inches is___________

    A 15 3/4

    B 17 3/4

    C 19 3/4

    D 21 3/4

    73. When using aluminum the roofing contractor must remember to use all except__________

    A Soldering

    B Rivets

    C Sealer

    D Welding

    74. The width of the pan is 20 3/4 inches. The seam height is 1 inch. The minimum ounce copper that can be

    used is ____________

    A 16 gage

    B 16 ounce

    C 26 gage

    D .032

    75. The minimum gage for stainless steel gutter is___________

    A 26

    B 16

    C 18

    D 28

    76. Which metal should not be soldered?

    A Aluminum

    B Brass

    C Copper

    D Die cast

    77. The minimum gage for galvanized expansion joint covers is ____________

    A 20

    B 22

    C 24

    D 26

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 13

    78. The rectangular gutter has a girth of 24 inches. The minimum gage galvanized steel to be used is

    _____________

    A 20

    B 22

    C 24

    D 26

    79. Gutter thermal expansion joints should be installed every _______________

    A 25 feet

    B 50 feet

    C 75 feet

    D 100 feet

    80. When fastening to concrete and not using reglets, the fasteners must be how many inches apart?

    A 8

    B 10

    C 12

    D 18

    81. To limit the effects of thermal expansion in gutters, the maximum practical gutter length to be served by a

    downspout is how many feet?

    A 12

    B 32

    C 42

    D 50

    82. A nail without a head is a ____________

    A Headless nail

    B Driver nail

    C Sinker nail

    D Slick head nail

    83. Nail sizes start at _____________

    A 1d

    B 2d

    C 3d

    D 4d

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 14

    84. Which is not a common description of the shank of a screw?

    A Standard thread

    B Reverse thread

    C Butress thread

    D Modified butress thread

    85. Which is not a physical factor affecting the screw's withdrawal resistance?

    A Size

    B Color

    C Pitch

    D Type

    86. The number of degrees in a standard thread is ____________

    A 30

    B 40

    C 90

    D 110

    87. The copper gutter has a girth of 22 inches. The minimum strap size should be ____________

    A 1/8 X 1

    B 1/4 X 1 1/2

    C 3/16 X 1

    D I/8 X 2

    88. The minimum gage for galvanized metal used as an expansion joint is ______________

    A 20

    B 22

    C 24

    D 26

    89. The scupper is installed through a raised roof and will discharge into a conductor head and downspout. The

    conductor head should be ___________ inches wider than the scupper.

    A 2

    B 4

    C 6

    D 8

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 15

    90. A conductor head used to move water into a downspout should be at least how many inches wider overall

    than the scupper?

    A 4

    B 3

    C 2

    D 1

    91. Horizontal cleats should be _______________

    A Continuous

    B Lapped

    C "Short" (by SMACNA definition)

    D "Long" (by SMACNA definition)

    92. Horizontal cleats should be in lengths ________________

    A Of at least 2 feet with 1/2 inch clearance between the ends

    B Of at least 3 feet with 1/4 inch clearance between the ends

    C Not to exceed 10 feet with 1/2 inch clearance between the ends

    D Not to exceed 12 feet with 1/4 inch clearance between the ends

    93. One type of joint approved for formed gravel-stop-fascia systems ______________

    A Involves welding

    B Uses a "lock-down" system

    C Is called the "combination joint"

    D Uses a cover plate

    94. On shingle, slate or tile roofs, the edges of valleys should be formed with hook edges and cleated on

    ____________ inch centers.

    A 24

    B 22

    C 20

    D 18

    95. Given a 2 1/2 x 3 inch diameter downspout leader and a 7.50 inches squared cross sectional area, the

    downspout leader capacity should be ___________

    A 30

    B 54

    C 92

    D 192

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 16

    96. Flashings are generally formed in ___________ foot sections.

    A 6

    B 8

    C 10

    D 12

    97. It is recommended that the depth of the conductor head's top opening equal of

    __________ its width.

    A 1/2

    B 2/3

    C 3/4

    D 7/8

    98. Where stationary louver blades exceed 36 inches in width, what should be used to connect the louvers?

    A 3 Number 8 sheet metal screws

    B A stiffener bar

    C A heel stiffener

    D A side latch with mobile vibrators

    99. The gutter is 6 inches wide. The elevation difference between the front and the back of the gutter should be

    how many inches?

    A .5

    B 1

    C 1.5

    D 2

    100. The copper for a 22-inch girthed gutter is ____________ ounce.

    A 16

    B 20

    C .042

    D 26

    101. The minimum width of a built-in gutter at the bottom is how many inches?

    A 3

    B 4

    C 6

    D 8

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 17

    102. The closure flange should be a minimum of how many inches wider than the conductor head on each side?

    A 6

    B 3

    C 1

    D 1/2

    103. Which of the following is considered an adequate roof support system?

    A Copper tin allow supports

    B Pressure treated wood sleepers

    C Metal "Z" bars running parallel to the roofing

    D Grid insulation and fasteners

    104. The cover plate on formed gravel-stop fascia should overlap each side how many inches?

    A 3

    B 6

    C 12

    D 18

    105. The minimum width of the chimney flashing base over the chimney cricket above the high side of the

    chimney is how many inches?

    A 12

    B 24

    C 36

    D 48

    106. Terne is Type 304 stainless steel coated with ______________

    A Zinc

    B Copper

    C Acid

    D Lead-tin alloy

    107. For standing seam roofs, the lap at the valley should be how many inches according to the Architectural

    Sheet Metal Manual?

    A 3

    B 5

    C 8

    D 12

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 18

    108. When installing a plain rectangular standard downspout 3 inches by 4 inches, the total square inches

    should be ___________

    A 12

    B 20

    C 10

    D 24

    109. An 8 inch wide gutter should have a depth of how many inches?

    A 4

    B 6

    C 8

    D 10

    110. To limit the effects of thermal expansion, gutters should be limited to a maximum of how many feet?

    A 40

    B 50

    C 75

    D 100

    111. The recommended gage for stainless steel counter flashing is ____________

    A 16

    B 24

    C 26

    D 28

    112. Gutter straps with an 18 inch girth made of stainless steel should be ___________

    A 1/8 X 1

    B 1/8 X 2

    C 1/4 X 1 1/2

    D 3/16 X 1

    113. Stainless steel rectangular gutter with an 18 inch girth should be what gage?

    A 24

    B 26

    C 22

    D 20

    114. To limit the effects of thermal expansion, the practical maximum gutter length is ___________

    A 40 feet

    B 50 feet

    C 75 feet

    D 100 feet

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 19

    115. Continuous means in lengths not to exceed ____________

    A 10 feet

    B 12 feet

    C 20 feet

    D 24 feet

    116. Metal coping single lap joints should be _____________ inches minimum width.

    A 2

    B 3

    C 4

    D 6

    117. Reglets cut in masonry should be a minimum of how many inches in depth?

    A 1

    B 1.5

    C 2

    D 3

    118. According to the Architectural Sheet Metal Manual, to determine the design area of a roof for a roof

    drainage system with a pitch of 6 to 8 inches per foot, multiply the plan area by the factor .

    A. 1.00

    B. 1.05

    C. 1.10

    D. 1.20

    119. According to the Architectural Sheet Metal Manual, downspouts should be selected to drain a maximum

    of feet of gutter.

    A. 20'

    B. 30'

    C. 40'

    D. 50'

    120. A plain round downspout having a nominal size of 4 inches has an area of square inches.

    A. 5.94

    B. 7.07

    C. 11.04

    D. 12.57

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 20

    121. The recommended minimum thickness of aluminum required to fabricate a rectangular design gutter

    having a girth of 24 inches is aluminum.

    A. 0.025

    B. 0.032

    C. 0.051

    D. 0.064

    122. The maximum distance between expansion joint and downspout for a built-in gutter fabricated out of 24

    gage stainless steel having a gutter bottom width of 10 inches and side angles of 90 degrees is feet.

    A. 19

    B. 20

    C. 22

    D. 27

    123. A copper gutter that is girthed at 18 inches should have brackets or straps a minimum of in size.

    A. 1/8" x 1"

    B. 1/4" x 1"

    C. 1/4" x 1 - 1/2"

    D. 1/4" x 2"

    124. A continuous cleat should be used at the drip edge when a gravel stop-fascia exceeds inches.

    A. 3 - 1/12

    B. 4

    C. 4- 1/2

    D. 5

    125. According to Architectural Sheet Metal Manual, the recommended minimum gage stainless steel required

    for counter flashings is gage stainless steel.

    A. 28

    B. 26

    C. 24

    D. 22

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 21

    126. The nominal thickness for 20 gage stainless steel sheets is millimeters.

    A. 0.4

    B. 0.6

    C. 0.8

    D. 1.0

    127. Standing seam metal roof pans should be installed with cleats nailed inches on center.

    A. 6

    B. 12

    C. 18

    D. 24

    128. Given: A 6" x 6" downspout, assuming a maximum storm, how much roof area can be drained of roof in

    Tampa, Florida is square feet.

    A. 110 square feet

    B. 660 square feet

    C. 1,980 square feet

    D. 3,960 square feet

    129. According to the Architectural Sheet Metal Manual, the area of a plain round 4 inch standard downspout

    is square inches.

    A. 5.94 square inches

    B. 7.07 square inches

    C. 11.04 square inches

    D. 12.5 7 square inches

    130. According to Architectural Sheet Metal Manual, the minimum gage galvanized steel gutter with a 22

    inch girth is .

    A. 16 gage

    B. 20 gage

    C. 22 gage

    D. 26 gage

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 22

    131. According the Architectural Sheet Metal Manual, gutterer bracket size for galvanized steel at 18 inch girth

    is .

    A. 3/16" x 1"

    B. 1/8” x 2"

    C. 1/8” x 1”

    D. 1/4" x'1/2"

    132. According to the Architectural Sheet Metal Manual, the minimum front width of a downspout splash pan

    is inches.

    A. 30 inches

    B. 18 inches

    C. 12 inches

    D. 1 inch

    133. According to the Architectural Sheet Metal Manual, the maximum distance between joints on formed

    gravel stop is feet.

    A. 8 feet

    B. 10 feet

    C. 12 feet

    D. 16 feet

    134. The minimum width for valley flashing on a roof with .a slope less than 6/12 is inches.

    A. 20inches

    B. 16 inches

    C. 10 inches

    D. 5 inches

    135. According to the Architectural Sheet Metal Manual, the minimum gage for copper valley flashing

    is gage.

    A. 22 gage

    B. 23 gage

    C. 24 gage

    D. 25 gage

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 23

    136. According to the Architectural Sheet Manual, the size of roof pans used on a flat seam roof is inches.

    A. 20" x 28"

    B. 18" x 26"

    C. 12" x 24"

    D. 10" x 8"

    137. The seam height of a pan 24” x 20-3/4” for a standing rood seam is inches.

    A. 3/4

    B. 1"

    C. 1-1/4"

    D. 1-1 /2"

    138. In a stationary formed louver with blades over 36 inches a size stiffener bar should be used

    to connect the louver blades.

    A. 1" x 1"

    B. 1-1 /2" x 1

    C. 1-1 /4" x 1"

    D. 1/8" x 1"

    139. According to the Architectural Sheet Metal Manual, the base gravity ventilator must be larger

    than the curb.

    A. 1 inch

    B. 2 inches

    C. 3 inches

    D. 4 inches

    140. Given: A six-inch gravel stop, the minimum lap on the nailer edge is inches.

    A. 1 inch

    B. 2 inches

    C. 3 inches.

    D. 4 inches

    141. Given: 16 inch coping with a 16-inch joint top width, the minimum thickness aluminum to fabricate the

    coping is gage.

    A. 26 gage

    B. 24 gage

    C. 22 gage

    D. 20 gage

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 24

    ANSWER KEY

    1. B SMACNA Architectural Sheet Metal Manual, 7 th Edition B.9

    2. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.1

    3. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    4. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.20

    5. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.58

    6. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.72

    7. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.76

    8. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.6

    9. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.8

    10. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.8

    11. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    12. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    13. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 8.16

    14. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.14

    15. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.14

    16. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.26

    17. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.14

    18. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 10.4

    19. D SMACNA Architectural Sheet Metal Manual, 7 th Edition B.1

    20. D SMACNA Architectural Sheet Metal Manual, 7 th Edition F.5

    21. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    22. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    23. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    24. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.34

    25. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.12

    26. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 3.3

    27. B SMACNA Architectural Sheet Metal Manual, 7 th Edition A.2

    28. A SMACNA Architectural Sheet Metal Manual, 7 th Edition A.1

    29. C SMACNA Architectural Sheet Metal Manual, 7 th Edition B.1

    30. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    31. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 25

    32. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    33. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.34

    34. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.12

    35. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 3.3

    36. B SMACNA Architectural Sheet Metal Manual, 7 th Edition A.2

    37. A SMACNA Architectural Sheet Metal Manual, 7 th Edition A.1

    38. C SMACNA Architectural Sheet Metal Manual, 7 th Edition B.1

    39. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.1

    40. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    41. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    42. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.46

    43. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.82

    44. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.2

    45. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.8

    46. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.6

    47. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.10

    48. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.20

    49. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    50. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.22

    51. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.22

    52. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.14

    53. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.12

    54. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.14

    55. C SMACNA Architectural Sheet Metal Manual, 7th Edition B.1

    56. C SMACNA Architectural Sheet Metal Manual, 7th Edition 10.4

    57. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.20

    58. D SMACNA Architectural Sheet Metal Manual, 7 th Edition A.1

    59. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.8

    60. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.2

    61. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    62. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    63. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.2

    64. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 26

    65. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.6

    66. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    67. A SMACNA Architectural Sheet Metal Manual, 7th Edition 1.4

    68. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.82

    69. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.6/A.1

    70. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.14

    71. B SMACNA Architectural Sheet Metal Manual, 7th Edition 4.6

    72. D SMACNA Architectural Sheet Metal Manual, 7th Edition 6.14

    73. A SMACNA Architectural Sheet Metal Manual, 7th Edition B.1

    74. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.14

    75. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    76. A SMACNA Architectural Sheet Metal Manual, 7 th Edition B.1

    77. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 5.12

    78. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    79. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    80. D SMACNA Architectural Sheet Metal Manual, 7th Edition 4.10

    81. D SMACNA Architectural Sheet Metal Manual, 7th Edition 1.4

    82. A SMACNA Architectural Sheet Metal Manual, 7 th Edition J.2

    83. B SMACNA Architectural Sheet Metal Manual, 7 th Edition J.3

    84. B SMACNA Architectural Sheet Metal Manual, 7 th Edition J.4

    85. B SMACNA Architectural Sheet Metal Manual, 7 th Edition J.4

    86. B SMACNA Architectural Sheet Metal Manual, 7 th Edition J.4

    87. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.34

    88. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 5.2

    89. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.66

    90. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.62

    91. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.2

    92. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.2

    93. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.8

    94. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    95. C SMACNA Architectural Sheet Metal Manual, 7 th Edition G.4

    96. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.18

    97 B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.60

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 27

    98. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 9.4

    99. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.10

    100. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    101. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.16

    102. D SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.62

    103. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.6

    104. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 2.8

    105. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.27

    106. D SMACNA Architectural Sheet Metal Manual, 7th Edition B.9

    107. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 6.17

    108. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    109. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.10

    110. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    111. C SMACNA Architectural Sheet Metal Manual, 7 th Edition 4.8

    112. A SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.34

    113. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.11

    114. B SMACNA Architectural Sheet Metal Manual, 7 th Edition 1.4

    115. A SMACNA Architectural Sheet Metal Manual 2.2

    116. B SMACNA Architectural Sheet Metal Manual 3.1

    117. B SMACNA Architectural Sheet Metal Manual 4.6

    118. C SMACNA Architectural Sheet Metal Manual 1.1

    119. D SMACNA Architectural Sheet Metal Manual 1.4

    120. D SMACNA Architectural Sheet Metal Manual 1.4

    121. C SMACNA Architectural Sheet Metal Manual 1.11

    122. D SMACNA Architectural Sheet Metal Manual 1.18

    123. A SMACNA Architectural Sheet Metal Manual 1.34

    124. D SMACNA Architectural Sheet Metal Manual

    125. B SMACNA Architectural Sheet Metal Manual 4.8

    126. D SMACNA Architectural Sheet Metal Manual A.1

    127. B SMACNA Architectural Sheet Metal Manual 6.14

    128. D SMACNA Architectural Sheet Metal Manual 1.2

    129. D SMACNA Architectural Sheet Metal Manual 1.4

    130. C SMACNA Architectural Sheet Metal Manual 1.11

  • 1 Exam Prep – SMACNA Architectural Sheet Metal 28

    131. C SMACNA Architectural Sheet Metal Manual 1.34

    132. B SMACNA Architectural Sheet Metal Manual 1.82

    133. C SMACNA Architectural Sheet Metal Manual 2.1

    134. A SMACNA Architectural Sheet Metal Manual 4.21

    135. B SMACNA Architectural Sheet Metal Manual 4.20

    136. A SMACNA Architectural Sheet Metal Manual 6.10

    137. B SMACNA Architectural Sheet Metal Manual 6.14

    138. D SMACNA Architectural Sheet Metal Manual 7.2

    139. B SMACNA Architectural Sheet Metal Manual 8.3

    140. A SMACNA Architectural Sheet Metal Manual 2.3

    141. D


Recommended