Date post: | 25-Dec-2015 |
Category: |
Documents |
Upload: | emerald-harrington |
View: | 213 times |
Download: | 0 times |
1 Range presentation‘10
Wall / V 12
Introduction
Arguments
Technical details
Installation
V 12
2 Range presentation‘10
V 12 / Introduction
The V 12 rangeThe V 12 range includes 2.5, 3.5, 5.0 and 6.5 kW mono split units, as well as 2x1 multi splits. All of them working with ON-OFF technology.
V 12 models have a modern design with a new bright digital display. Moreover, it includes an enhanced health air purifying system, and functions such as Low Noise, Sleep Function and Light Control.
Type Power Model
Single ON-OFF
025 V 12-025 W
035 V 12-035 W
050 V 12-050 W
065 V 12-060 W
Multi 2x1 ON-OFF 025+035 V 12-060 M2W
Introduction Arguments Technical details Installation
3 Range presentation‘10
2x1 DUST FILTER VERTICAL AIR SWING
TIMER
BIO BACTERIA KILLING
DC INVERTER
V 12 / Arguments / Features
COLORFUL LCD DIGITAL DISPLAY
SLEEP FUNCTION
AUTO OPERATION
HIGH EFFICIENCY
LOW NOISE
REMOTE CONTROL
LIGHT CONTROL
Modern DesignThe series comes with elegant blue color display which provides useful information for the user.
Air purifyingThis series includes a complete health air purifying system consisting of three filters; a cold catalyst filter, a bio filter and 2x1 anti dust filter.
High ComfortCustomer focused design and improved functions like Low noise and Vertical air swing provide more comfort to end users.
High EfficiencyThe majority of the range is A class energy efficiency.
Our DC Inverter Solution – Inverter TechnologyHigh modulating DC Inverter technology provides high efficiency, low sound and high comfort.
COLD CATALYST FILTER
Introduction Arguments Technical details Installation
4 Range presentation‘10
V 12 / Arguments / USPs
New displayBright digital display with elegant blue colour provides users with useful information such as Operation mode, Sleep function and Set temperature. It is a clear differentiation when compared with more simple LED lamps displays.
Modern design
Easily controlled by remote controlWith several functions including green light ON-OFF function on indoor display.
Introduction Arguments Technical details Installation
5 Range presentation‘10
V 12 / Arguments / USPs
Air purifying
Anti dust 2x1 filterThis filter neutralizes and protects the ambient air from acarus, microbes and dust through its unique 2 in 1 effect (it is also antiallergenic and antibacterial).
Bio filterA layer of special material is installed in the filtration network of the unit. When the unit starts working, slow release technology purifies the ambient air, providing moisturization and improving health effects on the skin.Cold catalyst filterThis filter has anti-odour and sterilization effects. It can completely degrade methyl oxide (which has cancerogenic effects) from the ambient air. It also effectively removes odd odours like those of methyl hydrosulfate, ethyl mercaptan etc. Compared with optical catalyst filters, the cold catalyst has the advantage of recycling without going through the regeneration process.
Introduction Arguments Technical details Installation
6 Range presentation‘10
Customer focused design provides more comfort to end users.Special functions such as Sleep function, Auto operation, a complete Health Air Purifying system, Light control via remote button, Universal indoor and Low noise are designed to bring comfort to the final users.
V 12 / Arguments / USPs
Comfort
SLEEP LOW NOISE
HEALTH AIR PURIFYING
AUTO (it is possible to choose the temperature in this mode)
LIGHT CONTROL
Introduction Arguments Technical details Installation
7 Range presentation‘10
V 12 / Arguments / USPs
High efficiency
Less efficient
More efficient
Less efficient Less savings
More savingsMore efficient
‘A’ Class range provides optimum comfort with minimum consumption of energy.
Cost SavingsEnergy
Introduction Arguments Technical details Installation
8 Range presentation‘10
V 12 / Technical Details / Technical Specifications
Introduction ArgumentsTechnical detailsInstallation
Feature UnitsModel
V 12-025 W V 12-035 W V 12-050 W V 12-060 W
Indoor Unit V 12-025 HWI V 12-035 HWI V 12-050 HWI V 12-060 HWI
Outdoor Unit V 12-025 HWO V 12-035 HWO V 12-050 HWO V 12-060 HWO
Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50
Cooling capacitykW 2.86 3.21 5.40 6.70
BTU 9,761 10,955 18,429 22,866
Power Input kW 0.89 1.00 1.68 2.09
EER 3.21 3.21 3.21 3.21
Energy level class A A A A
Heating capacitykW 2.95 3.43 6.06 7.05
BTU 10,068 11,706 20,682 24,060
Power input kW 0.81 0.94 1.68 2.05
COP 3.64 3.65 3.61 3.44
Energy level class A A A B
Air flow volume m3/h 355/391/450 391/455/500 672/736/800 708/804/900
Catalogue sound pressure IU dB(A) 28/34/40 29/35/40 32/39/43 33/40/44
Catalogue sound pressure OU dB(A) 50 50 53 53
Compressor type Rotary Rotary Rotary Rotary
Expansion system Capillary Capillary Capillary Capillary
9 Range presentation‘10
V 12 / Technical Details / Technical Specifications
Introduction ArgumentsTechnical detailsInstallation
Feature UnitsModel
V 12-060 M2W
Indoor Unit 1 & 2 V 12-025 MHWI & V 12-035 MHWI
Outdoor Unit V 12-060 M2NHWO
Power supply V/Ph/Hz 230/1/50
Cooling capacitykW 5.80
BTU 19,794
Capacity by indoor 1 & 2 kW 2.60 & 3.20
Power Input kW 1.71
EER 3.39
Energy level class A
Heating capacitykW 6.38
BTU 21,774
Capacity by indoor 1 & 2 kW 2.86 & 3.52
Power input kW 1.86
COP 3.44
Energy level class B
Air flow volume 1 & 2 m3/h 300/400/500 & 300/400/500
Catalogue sound pressure IU 1 & 2 dB(A) 28/34/40 & 28/34/40
Catalogue sound pressure OU dB(A) 52
Compressor type Rotary
Expansion system Capillary
10 Range presentation‘10
V 12 / Technical Details / Temperature range
Introduction ArgumentsTechnical detailsInstallation
Model
Cooling (ºC) Heating (ºC)
Indoor low Outdoor lowOutdoor
highIndoor high Outdoor low
Outdoor high
V 12-025 W 16 8 43 32 -7 32
V 12-035 W 16 8 43 32 -7 32
V 12-050 W 16 8 43 32 -7 32
V 12-060 W 16 8 43 32 -7 32
V 12-060 M2W
16 8 43 32 -7 32
11 Range presentation‘10
V 12 / Technical Details / Drawings
Introduction ArgumentsTechnical detailsInstallation
Indoor dimensions
Model HxLxD (mm) Weight (kg)
V 12-025 HWI 250x745x195 9
V 12-035 HWI 250x745x195 9
V 12-050 HWI 292x900x215 14
V 12-060 HWI 292x900x215 14
V 12-025 MHWI 280x800x190 10
V 12-035 MHWI
280x800x190 10
Outdoor dimensions
Model HxLxD (mm) – I/J (mm)Weight
(kg)
V 12-025 HWO 500x700x225 – 260/510 25
V 12-035 HWO 540x795x255 – 280/510 36
V 12-050 HWO 540x795x255 – 280/510 38
V 12-060 HWO 605x850x295 – 305/500 45
V 12-060 M2HWO
645x925x430 – 400/692 64
12 Range presentation‘10
V 12 / Installation
Model Units V 12-025 W V 12-035 W V 12-050 W V 12-060 W
Pipe connection liq/gas inches 1/4” – 3/8” 1/4” – 3/8” 1/4” – 1/2” 1/4” – 1/2”
Max. pipe length m 20 20 25 25
Max. height IU under OU m 10 10 15 15
Max. height OU under IU m 10 10 15 15
Refrigerant type gr R410A R410A R410A R410A
Refrigerant charge gr 560 1,120 1,500 1,900
Additional charge per meter
gr 28 28 40 50
Mono split
Max. Pipe Length = a + b + c = a + d + eMax. Height IU under OU = h2Max. Height OU under IU = h1
Introduction Arguments InstallationTechnical details
13 Range presentation‘10
V 12 / Installation
Multi splitModel Units V 12-060 M2W
Pipe connection liq/gas IU 1 & 2 inches 1/4”–3/8” & 1/4”–1/2”
Pipe connection liq/gas OU inches 1/4”–3/8” & 1/4”–1/2”
Max. pipe length m 20 + 20
Max. height IU under OU m 10
Max. height OU under IU m 10
Refrigerant type gr R410A
Refrigerant charge gr 1,000 + 1,200
Additional charge per meter gr 30 - 35
Total Max. Length = L1 + L2 + L3Max. Height IU under OU = h2Max. Height OU under IU = h1L1 = a + b + cL2 = dL3 = e + f + gMax. single pipe length = L1 = L2 = L3
Introduction Arguments InstallationTechnical details
14 Range presentation‘10
Controls / Remote controls / Description / V 12
Adapts the temperature during night time
Selects the mode:
AUTO/COOL/DRY/HEAT/FAN
Activates the ion operation (function not available)
Directs the airflow up/down
Selects the Timer start-up time
Switches off the light of the indoor display
Directs the airflow up or down
Starts working at maximum fan speed
Locks the remote control button
Switches the device ON-OFF
Increases/Decreases the temperature by 1ºC and sets the timer