Page 1: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

1 Range presentation‘10

Wall / V 12

Introduction

Arguments

Technical details

Installation

V 12

Page 2: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

2 Range presentation‘10

V 12 / Introduction

The V 12 rangeThe V 12 range includes 2.5, 3.5, 5.0 and 6.5 kW mono split units, as well as 2x1 multi splits. All of them working with ON-OFF technology.

V 12 models have a modern design with a new bright digital display. Moreover, it includes an enhanced health air purifying system, and functions such as Low Noise, Sleep Function and Light Control.

Type Power Model

Single ON-OFF

025 V 12-025 W

035 V 12-035 W

050 V 12-050 W

065 V 12-060 W

Multi 2x1 ON-OFF 025+035 V 12-060 M2W

Introduction Arguments Technical details Installation

Page 3: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

3 Range presentation‘10

2x1 DUST FILTER VERTICAL AIR SWING

TIMER

BIO BACTERIA KILLING

DC INVERTER

V 12 / Arguments / Features

COLORFUL LCD DIGITAL DISPLAY

SLEEP FUNCTION

AUTO OPERATION

HIGH EFFICIENCY

LOW NOISE

REMOTE CONTROL

LIGHT CONTROL

Modern DesignThe series comes with elegant blue color display which provides useful information for the user.

Air purifyingThis series includes a complete health air purifying system consisting of three filters; a cold catalyst filter, a bio filter and 2x1 anti dust filter.

High ComfortCustomer focused design and improved functions like Low noise and Vertical air swing provide more comfort to end users.

High EfficiencyThe majority of the range is A class energy efficiency.

Our DC Inverter Solution – Inverter TechnologyHigh modulating DC Inverter technology provides high efficiency, low sound and high comfort.

COLD CATALYST FILTER

Introduction Arguments Technical details Installation

Page 4: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

4 Range presentation‘10

V 12 / Arguments / USPs

New displayBright digital display with elegant blue colour provides users with useful information such as Operation mode, Sleep function and Set temperature. It is a clear differentiation when compared with more simple LED lamps displays.

Modern design

Easily controlled by remote controlWith several functions including green light ON-OFF function on indoor display.

Introduction Arguments Technical details Installation

Page 5: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

5 Range presentation‘10

V 12 / Arguments / USPs

Air purifying

Anti dust 2x1 filterThis filter neutralizes and protects the ambient air from acarus, microbes and dust through its unique 2 in 1 effect (it is also antiallergenic and antibacterial).

Bio filterA layer of special material is installed in the filtration network of the unit. When the unit starts working, slow release technology purifies the ambient air, providing moisturization and improving health effects on the skin.Cold catalyst filterThis filter has anti-odour and sterilization effects. It can completely degrade methyl oxide (which has cancerogenic effects) from the ambient air. It also effectively removes odd odours like those of methyl hydrosulfate, ethyl mercaptan etc. Compared with optical catalyst filters, the cold catalyst has the advantage of recycling without going through the regeneration process.

Introduction Arguments Technical details Installation

Page 6: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

6 Range presentation‘10

Customer focused design provides more comfort to end users.Special functions such as Sleep function, Auto operation, a complete Health Air Purifying system, Light control via remote button, Universal indoor and Low noise are designed to bring comfort to the final users.

V 12 / Arguments / USPs

Comfort

SLEEP LOW NOISE

HEALTH AIR PURIFYING

AUTO (it is possible to choose the temperature in this mode)

LIGHT CONTROL

Introduction Arguments Technical details Installation

Page 7: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

7 Range presentation‘10

V 12 / Arguments / USPs

High efficiency

Less efficient

More efficient

Less efficient Less savings

More savingsMore efficient

‘A’ Class range provides optimum comfort with minimum consumption of energy.

Cost SavingsEnergy

Introduction Arguments Technical details Installation

Page 8: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

8 Range presentation‘10

V 12 / Technical Details / Technical Specifications

Introduction ArgumentsTechnical detailsInstallation

Feature UnitsModel

V 12-025 W V 12-035 W V 12-050 W V 12-060 W

Indoor Unit V 12-025 HWI V 12-035 HWI V 12-050 HWI V 12-060 HWI

Outdoor Unit V 12-025 HWO V 12-035 HWO V 12-050 HWO V 12-060 HWO

Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50

Cooling capacitykW 2.86 3.21 5.40 6.70

BTU 9,761 10,955 18,429 22,866

Power Input kW 0.89 1.00 1.68 2.09

EER 3.21 3.21 3.21 3.21

Energy level class A A A A

Heating capacitykW 2.95 3.43 6.06 7.05

BTU 10,068 11,706 20,682 24,060

Power input kW 0.81 0.94 1.68 2.05

COP 3.64 3.65 3.61 3.44

Energy level class A A A B

Air flow volume m3/h 355/391/450 391/455/500 672/736/800 708/804/900

Catalogue sound pressure IU dB(A) 28/34/40 29/35/40 32/39/43 33/40/44

Catalogue sound pressure OU dB(A) 50 50 53 53

Compressor type Rotary Rotary Rotary Rotary

Expansion system Capillary Capillary Capillary Capillary

Page 9: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

9 Range presentation‘10

V 12 / Technical Details / Technical Specifications

Introduction ArgumentsTechnical detailsInstallation

Feature UnitsModel

V 12-060 M2W

Indoor Unit 1 & 2 V 12-025 MHWI & V 12-035 MHWI

Outdoor Unit V 12-060 M2NHWO

Power supply V/Ph/Hz 230/1/50

Cooling capacitykW 5.80

BTU 19,794

Capacity by indoor 1 & 2 kW 2.60 & 3.20

Power Input kW 1.71

EER 3.39

Energy level class A

Heating capacitykW 6.38

BTU 21,774

Capacity by indoor 1 & 2 kW 2.86 & 3.52

Power input kW 1.86

COP 3.44

Energy level class B

Air flow volume 1 & 2 m3/h 300/400/500 & 300/400/500

Catalogue sound pressure IU 1 & 2 dB(A) 28/34/40 & 28/34/40

Catalogue sound pressure OU dB(A) 52

Compressor type Rotary

Expansion system Capillary

Page 10: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

10 Range presentation‘10

V 12 / Technical Details / Temperature range

Introduction ArgumentsTechnical detailsInstallation

Model

Cooling (ºC) Heating (ºC)

Indoor low Outdoor lowOutdoor

highIndoor high Outdoor low

Outdoor high

V 12-025 W 16 8 43 32 -7 32

V 12-035 W 16 8 43 32 -7 32

V 12-050 W 16 8 43 32 -7 32

V 12-060 W 16 8 43 32 -7 32

V 12-060 M2W

16 8 43 32 -7 32

Page 11: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

11 Range presentation‘10

V 12 / Technical Details / Drawings

Introduction ArgumentsTechnical detailsInstallation

Indoor dimensions

Model HxLxD (mm) Weight (kg)

V 12-025 HWI 250x745x195 9

V 12-035 HWI 250x745x195 9

V 12-050 HWI 292x900x215 14

V 12-060 HWI 292x900x215 14

V 12-025 MHWI 280x800x190 10

V 12-035 MHWI

280x800x190 10

Outdoor dimensions

Model HxLxD (mm) – I/J (mm)Weight

(kg)

V 12-025 HWO 500x700x225 – 260/510 25

V 12-035 HWO 540x795x255 – 280/510 36

V 12-050 HWO 540x795x255 – 280/510 38

V 12-060 HWO 605x850x295 – 305/500 45

V 12-060 M2HWO

645x925x430 – 400/692 64

Page 12: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

12 Range presentation‘10

V 12 / Installation

Model Units V 12-025 W V 12-035 W V 12-050 W V 12-060 W

Pipe connection liq/gas inches 1/4” – 3/8” 1/4” – 3/8” 1/4” – 1/2” 1/4” – 1/2”

Max. pipe length m 20 20 25 25

Max. height IU under OU m 10 10 15 15

Max. height OU under IU m 10 10 15 15

Refrigerant type gr R410A R410A R410A R410A

Refrigerant charge gr 560 1,120 1,500 1,900

Additional charge per meter

gr 28 28 40 50

Mono split

Max. Pipe Length = a + b + c = a + d + eMax. Height IU under OU = h2Max. Height OU under IU = h1

Introduction Arguments InstallationTechnical details

Page 13: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

13 Range presentation‘10

V 12 / Installation

Multi splitModel Units V 12-060 M2W

Pipe connection liq/gas IU 1 & 2 inches 1/4”–3/8” & 1/4”–1/2”

Pipe connection liq/gas OU inches 1/4”–3/8” & 1/4”–1/2”

Max. pipe length m 20 + 20

Max. height IU under OU m 10

Max. height OU under IU m 10

Refrigerant type gr R410A

Refrigerant charge gr 1,000 + 1,200

Additional charge per meter gr 30 - 35

Total Max. Length = L1 + L2 + L3Max. Height IU under OU = h2Max. Height OU under IU = h1L1 = a + b + cL2 = dL3 = e + f + gMax. single pipe length = L1 = L2 = L3

Introduction Arguments InstallationTechnical details

Page 14: 1 Range presentation ‘1 0 Wall / V 12 Introduction Arguments Technical details Installation V 12.

14 Range presentation‘10

Controls / Remote controls / Description / V 12

Adapts the temperature during night time

Selects the mode:

AUTO/COOL/DRY/HEAT/FAN

Activates the ion operation (function not available)

Directs the airflow up/down

Selects the Timer start-up time

Switches off the light of the indoor display

Directs the airflow up or down

Starts working at maximum fan speed

Locks the remote control button

Switches the device ON-OFF

Increases/Decreases the temperature by 1ºC and sets the timer