Page No. 4.........Hydro Tester
5........ Water Bath
6........Tensile Tester
7........ CNC Milling
8........OIT Tester
9........MFI Tester
10......Carbon Content
11......Dispersion Tester
12......Density Tester
13......Falling Dart
15......RCP Tester
16......SCG Tester
17......Falling Weight
18......Cruch Tester
19......Hot Press
20......Roto Molding
21......Opacity Tester
22.......DiChloromethane Tester
23......ESCR Tester
24......Leakage Under Bending
25.......Leakage Under Vacuum
26.......HDT/Vicat Tester
27......Dripping Pipe Tester
28...... PVC Duct Bending
29....... Bulk Density
31.......Thermal Cycling
33....... Oven
34.......Circometers
35.......Furnace
36.......Adjustable Calibrator
37......Gravimetric
38......Ultrasonic
30.......Notch Maker
The internal pressure creep test is a test procedure for determining the strength of thermoplastic
pipes. The samples are subjected to a constant hydrostatic internal pressure at a constant
temperature. The AHP Airless model provides customers with small test volumes with compact
option for carrying out the tests.
Description
Airless Hydrostatic and Burst Tester
Data communica-
tion via USBRemote main -
tenance via Internet
Standards
ISO 1167
ASTM D 1598
ASTM D 1599
Pressure range up to bar 100
Integrated high-pressure pump l
Pump capacity l/min 11
Stainless steel pressure reservoir l
Number of stations 4
Pressure regulation via microprocessor controller l
SensLine connection l
10-bar pressure transducer
16-bar pressure transducer
25-bar pressure transducer
40-bar pressure transducer
60-bar pressure transducer
100-bar pressure transducer
Accuracy class for pressure transducer 0.50% of full scale of pressure transducer
External control unit (PC) l
Data interface to internal programs USB
Specifications
Width mm 600
Depth mm 600
Height mm 1400
Weight kg 200
Voltage data 230/400 V, 50/60 Hz
l included ¡ available/optional
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
4
The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes.
The samples are subjected to a constant hydrostatic internal pressure at a constant temperature. The high
reliability, durability of the material used and the constant temperatures in the test tank with respect to
both volume and time provide particularly reliable test conditions. Wide range of tank dimensions and
connection options, enables flexibly to various operating conditions.
Description
Test Tanks for Pipe Testing
Double insulation of
inner tank
Standards
ISO 1167
ASTM D 1598
ASTM D 1599
Spatial temperature constancy
Quick plugs
V1
V2
V3
Water depth mm 1000 1500 1500
Width (internal) mm 900 1200 1500
Length (internal) mm 1200 1500 1500
Width (external) mm 1000 1300 1600
Length (external) mm 1600 2100 2100
Height closed (external) mm 1300 1800 1800
Height open (external) mm 2200 3000 3300
Number of manifold slots on request
Number of suspension rails (included) 2 2 2
Heating power kW 6 6 9
Inner tank material
All parts coming into contact with water stainless
SS304
l
Water temperature °C
Water temperature (with chiller) °C 20 -95
2
Water temperature adjustable increments °C
Temperature constancy °C
Circulation system l
Connection and interface for chiller l
Overtemperature shutdown l
Voltage data 380 V-3Ph, 50/60 Hz
l included ¡ available/optional
Specifications
Pneumatic door l
1
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
RT -95
5
Description
Tensile tester
The universal tensile tester is used for performing tension, pressure or bending tests. The
classic application is the tensile test. This involves subjecting a sample to an increasing tensile
load until it breaks.
Integrated touch
display (optional)Data export to Excel Standards
ISO 527
ISO 6259
ASTM D 638
2 To
ns
5 To
ns
Test force kN 5 10
Structure
Max. crosshead travel excluding grips mm 1000 1000
Crosshead speed mm/min 0.001 –
3000.001 –
300
Speed accuracy %
Extensometer ¡
Wedge grips ¡
Grips for large wall thickness ¡
Peel test fi xture for composite pipes ¡
Compression plates ¡
Permissible ambient temperature °C -10 to +40
Permissible relative humidity 10-90%
Width mm 800 800
Depth mm 500 500
Height mm 1500 1500
Weight kg 160 190
Voltage data 230 V, 50/60 Hz
l included ¡ available/optional
Specifications
+-0.1
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
6
The test bar milling machine enables bar-shaped plastic samples to be produced for tension, pressure, bending and flexural impact tests in accordance with a wide range of standards.
Description
CNC Tensile Test Sample Milling Machine
Pneumatic
clamping (Option)CNC-controlled
positioning of
3 axes
Standards
ISO 179/180 ISO 16770
ISO 527 ASTM D 638
ISO 6259 ASTM D 1822
Replaceable milling table
Milling table with mechanical clamping device l
Max thickness of samples Max. thickness 50 mm
- Number of test bars Max. 1
Rotational speed of spindle Between 3000 and 18000 per minute
Hard metal milling cutter Ø 10 mm l
Diamond milling cutter ¡
Milling program MACH3
Operation via PC l
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%
X Axis travel mm
Y Axis travel mm 400
Width mm 600
Depth mm 800
Height mm 900
Weight kg 250
Voltage data 230 V, 50 Hz
300
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
¡
Y Axis travel mm 90
7
Standards
ISO 11357-6 ASTM D 3895
EN 728
ASTM D 3418
DSC for determining the oxidation induction time for polymer pipe and
protective pipe systems as well as moulded elements made of
polyolefin.
Description
OIT measuring device
Specifications
Temperature range when cooling with compressed air °C RT* to +300
Sensor with high resolution l
Software-controlled switching valves for two gases l
Integrated mass flow controller for two gases ¡
Calibration kit l
Sensitivity µV/mW 3,6 to 4,0
Gas fl ow ml/minute (0) to 5 to 250
Heating rate K/minute 0.001 to 500
Temperature accuracy K 0.1
Operation via PC l
PC including software l
Permissible environmental temperature °C 20 ± 5
Permissible relative humidity % 60 ± 20
Dimensions of measuring device (width, x depth x height) mm 300 x 500 x 180
Weight of the measuring device kg approx. 30
Voltage data 230 V, 50 Hz
l included ¡ available/optional
* RT = room temperature
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
8
Description
MFR tester
The MFR Tester used to determine the material output from 2.095mm diameter hole in specified
loading and temperature condition.
PID Control Timer Controlled Standards
ISO 1133
ASTM D 1238
Test temperature °C 50 to 300 in increments of 0.1 K
Increase in the temperature range up to 450 °C
Temperature regulating accuracy 1 K at the nozzle
0.325-kg load weight ¡
1.200-kg load weight ¡
2.160-kg load weight l
3.800-kg load weight ¡
5.000-kg load weight l
10.000-kg load weight ¡
11.600-kg load weight ¡
Automatic cutting device
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 540
Depth mm 440
Height mm 920
Weight (without weight discs) kg 98
Voltage data 230 V, 50/60 Hz
l included ¡ available/optional
Specifications
¡l
¡¡l
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Thermal Printer ¡¡l
9
The test method is based on pyrolitic decomposition of the material in an inert gas flow (nitrogen).
Description
Carbon Black Tester
Over temperature
protection
Standards
ISO 6964
ASTM D 1603
Furnace temperature range °C 0 – 900
Furnace accuracy 1 K
Flow meter 8-80 ml/min
Power kW 1
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%
Width mm 700
Depth mm 600
Height mm 900
Weight kg Approx. 50
Voltage 230 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Easy sample handling. Thanks to special design sample trolley
10
Description
Microscope and digital camera
A microscope is required to examine the agglomerates in
polyelefins for determining the degree of dispersion. The digital
camera is used for images acquisition, documentation and archiving.
It is supplied with image processing software and a PC for automatic
determining the dispersion grade.
Standards
ISO 18553
ASTM D 5596
Microscope
Phototube Binocular 30°/23 (50:50)
Stand With manual stage focusing
Coarse drive 2 mm/revolution
Fine drive 0.2 mm/revolution
Lifting range Max. 25 mm
Height stop Mechanically adjustable
Object lenses Multiple nosepiece
5 x 0.12
10 x 0.25
20 x 0.45
Eye pieces 10X, 16X
Light source Halogen lamp
Digital camera incl. software
Max. resolution 1280 x 1024 pixels
Image refresh rate Max. 25 images/s
Exposure time 9 µs – 17209 ms
Digital interface USB 2.0 (incl. USB cable)
PC l
Permissible ambient temperature +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 300
Depth mm 721
Height mm 505
Weight kg Approx. 20
Voltage data 100-127 V, 200-240 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
11
DescriptionIt is used in important tests such as MFR, carbon black content, K-value, degree of crosslinking,
volatile matter, water absorption, etc.
Analytical Balance+Density Kit
Specifications
HR
200
Weighing capacity g 200,210,220
Readability mg 0.1
Repeatability (standard deviation) $±mg 0.1
Linearity deviation $±mg 0.2
Typical response time s 2
Pan size diameter mm 85
Height of the weighing chamber mm 209
Net weight, approx. kg 5.7
Dimensions, D x W x H mm 213(W)x319(D)x301(H)
CE-conformity l
Draft shield for analytical balance - Analytical draft shield chamber - Interior chamber with spill-proof design
- All panes can be exchanged
Housing Chemically resistant housing
Weigh cell - Mounted on a heavy-duty die-cast plate - Stable and repeatable weighing results
In-use cover Provides added protection against dirt
Underfl oor weighing Integrated
Built-in application programs Special lab applications such as Mixing, Components Conversion, Weighing, Density,Percentage, Peak Hold, Counting and Unstable Conditions
Voltage data 100-240 V, -15%/+10%, 50-60 Hz, 0,2A
Relative humidity Max. 70%, non-condensing
Ambient temperature °C + 10°C to +30 °C
l included ¡ available/optional
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
ISO 1183
12
Before starting the test, choose test method, and estimate an initial mass and Δm. Start the test. If the first
specimen fails, decrease the mass of the falling dart by Δm. If the first specimen is not a failure, increase the
mass of the falling dart by Δm. Continue the test according to this rule. In brief, increase or decrease by Δm
according to whether the former specimen is a failure or not. After 20 specimens, calculate the total number of
failed specimens N. If N equals to 10, the test is over. If N is less than 10, add specimens and continue to test
until N equals to 10. If N is greater than 10, add specimen and continue the test until the number of non-failure
specimens reaches 10. Then the tester calculates the test results automatically according to specific formulas.
Description
Falling Dart Impact Tester for Films7" Touch Monitor Standards
ISO 7765-1-1988
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Thermal Printer USB Data Out
Specifications FDI-03Test Method Method A or Method B is optional
Test Range Method A: 50 ~2000 g (weights on request)Method B: 300 ~2000 g (weights on request)
Accuracy 0.1 g (0.1J)
Specimen Clamp Pneumatic Clamp
Gas Supply Pressure 0.6 MPa (outside of supply scope)
Port Size Φ6 mm
Specimen Size >150 mm x150 mm
Power Supply 220VAC 50Hz / 120VAC 60Hz
Net Weight 70 kg
Instrument Dimension Method A: 500 mm (L) x 450 mm (W) x1320 mm (H) Method B: 500 mm (L) x 450 mm (W) x2160 mm (H)
Standard
Configurations Method A Accessories, Touch Screen and Micro Printer Method B Accessories
Note 1. The air supply port of this instrument is Φ6 mm ;2. Customers will need to prepare for compressed air supply.
ASTM D1709
13
n Basic unit with containment cage up to 250 mm
n Three strike speeds: 10, 15 and 20 m/s
n Touch controller
n Options: Freeze Cabin
External Compressed air supply
Standard equipment
Test unit for rapid crack propagation (RCP S4) Variable knife
speeds
Sample feed trolly Standards
ISO 13477
The RCP tester conveniently and accurately determines
the critical pressure and critical temperature for rapid
crack propagation in PE pressure pipes.
Description
Sample dimensions mm 32 – 250
Regulation of fi lling pressure Manually
Regulation of test pressure Automatic
Pressure transducer bar 25
Absolute measuring accuracy 0.5% of full scale of pressure transducer
Operation via Touch display 16"
Display of fi lling pressure At manometer (max. 25 bar)
Display of test pressure On Monitor
Compressed air supply 40-bar compressed air supply unit min 750 l/min
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width of test unit mm 790
Depth of test unit mm 2050
Height of test unit mm 2250
Weight of test unit kg 345
Width of control panel mm 600
Depth of control panel mm 600
Height of control panel mm 1200
Weight of control panel kg 100
Voltage data 230/400 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
14
It is used for making V-shaped nothes in polyolefin pipes in accordance with ISO 13479 for slow crack growth testing.
Description
Notch milling machine
Standards
ISO 13479
Pipe outside diameter mm63 – 25063 – 630
Max. pipe length mm 2000
Notch length mm 50 – 630
Wall thickness mm >5
V milling head (standard parameters) l
Diameter mm 200
Number of teeth 20
Rotational speed of motor 703 rpm
Rapid longitudinal feed rate mm/min 800
Slow longitudinal feed rate mm/min 140
0.01 (mm/rev)/tooth
Face milling cutter for wall thicknesses >50 mm ¡
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 2200
Depth mm 1200
Height mm 2100
Weight kg 550
Voltage data 230/400 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Cutting feed rate (standard value)
15
The falling weight tester is used to determine the external impact resistance of thermoplastic
pipes using the staircase or round-the-clock method according to EN744.
Description
Falling weight tester 25 impacts per
minute at a drop
height of 2 m
Standards
EN 744 ASTM D 2444
EN 1411
ISO 3127
V1
V2
Max. drop height m 2 2
Max. sample diameter mm 710 1600
Max. impact frequency per minute (dependent on operator) 25 25
Accuracy of height adjustment mm ±10
Drop weights kg Max. 16
Nose design Depending on the applicable standards
Lowest drop height without double impact m Typically 0.5 (dependent on sample)
Operation/visualisation 5" Touch display
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width of tester mm 900 2000
Depth of tester mm 800 800
Height of tester mm 3900 5000
Width of control cabinet mm 600
Depth of control cabinet mm 400
Height of control cabinet mm 1000
Voltage data 230/400 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
16
DescriptionImpact testing is used to determine material behavior at higher deformation speeds. AHP offers a
wide range of pendulum Charpy/Izod impact testers for tests according to the relevant test
standards. These pendulum Izod/Charpy impact testers cover a range from 0.5 Joules to 50
Joules for plastics testeing. These are available with digital touch displays and with a range of
different options especially made for your tests (e.g. tensile impact tests for UPVC profiles, ....).
Pendulum Impact Tester
Specifications
Energy 5.5J, 11J, 22J (Izod Testing)7.5J, 15J, 25J, 50J (Charpy Testing)
Span of Charpy 62
Izod testing Impact Speed m/s 3.5
Radius of striking edge
Location of striking edge above top surface of support 22±0.05
Notch A
Notch B
Charpy testing Impact Speed 3.8
Radius of striking edge 2±0.5
Angle of striking edge 30°±1°
Notch A
Notch B
Notch C
Voltage data 230 V, 50 Hz
l included ¡ available/optional
45º±1º Radius of the notch bottom R=0.25±0.05mm
45º±1º Radius of the notch bottom R=1±0.05mm
0.8±0.2
Standards
ASTM D256
ISO 179
ISO 180
m/s
mm
ASTM D6110
J
mm
mm
45º±1º Radius of the notch bottom R=0.25±0.05mm
45º±1º Radius of the notch bottom R=1±0.05mm
45º±1º Radius of the notch bottom R=0.10±0.02mm
Gross Weight 100Kg
Integrated touch
display (optional)Data export to PC
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
17
Description
ElectroFusion fittings are specifically designed for reliable, high performance pipe joining and
long system life. AHP offers a diverse range of electro fusion mechanical testing machines including
ISO 13954 Peel Decohesion Testing ISO 13955 Crush Testing ISO 13956 Decohesion testing of Saddle
fusion joints.
Also we offer dual use machine for both PE pipes squeeze-off tests and mechanical tests of EF joints.
Crush-Squeeze Tester
Specifications
Moving plate speed mm/min Adjustable (!00+-10 mm/min)
Force mechanism Hydraulic
Max press force T 10
Force indicator
Stop mechanism Standard spacers or sliding switch
Max pipe size
Column shafts Hard chrome plated
Hydraulic pack Electrically controlled
Squeeze-off bars
Total power W 2000
2-Column design
Weight kg 400
Voltage data 230 V, 50 Hz
l included ¡ available/optional
225
l
l
mm
¡
Standards
ISO 13955
ISO 13956
ISO 13954
EN 1555
Quick Change from Squeeze to crush tester
Hydraulic Type
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
18
DescriptionAHP manufacture a range of heated platen presses for compression molding of rubber, plastics and
composites; also for laminating, laboratory and R&D.
Electrically or oil heated platens are uniquely designed for uniform heat distribution and fine
temperature control. Compressed air or water cooling is also available for controlled cooling of the
sample.
Enhanced programmable press controls for multiple ramp profiles, data
logging of press load and position in addition to the platen temperature
parameters are also available as option.
Manual Hot Press
Specifications
Max. plate temperature °C 300
Temperature constancy °C ±2
Max press force Kg 200
Heating method Rod element
Platen size
Force mechanism
Temperature controller PID digital on both platens
Cooling method Air
Water circulation cooling
Heating power W 2000
Total power W 2500
Platens teflon cover
Weight kg 25
Voltage data 230 V, 50 Hz
l included ¡ available/optional
30*40
Manual
l
mm
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
19
DescriptionAHP manufacture a range of laboratory roto-moulding machine for compound manufactureres
research purposes to study mould melt flow properties.
Laboratory Roto-Molding Machine
Specifications
Max. temperature °C 350
Temperature constancy °C ±2
Max rotational speed rpm 50
Heating method Resistance heating elements
Chamber diameter
Control type
Mould type Aluminum
Cooling method Air
Carrier
Heating power W 2000
Total power W 9000
Computer
Computer Connection USB
Voltage data 230 V, 50 Hz
l included ¡ available/optional
600
PLC and computer software
mm
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
Manual
20
Description
The Pipe Opacity Tester is used to determine the opacity of pipes and fittings. It is an ideal device for pipe
manufacturers, research and inspection institutions. It consists of optical source, Luminous flux
collection system, sliding sample chamber and specimen support.
Opacity Tester
Specifications
Light source Parallel optical source
Lux meter 24 bit luminous flux collection
Diameter range of pipes mm 20-63 mm
Resolution
Accuracy <0.05% FS
Display
Lux range
Lux display resolution 1
Operating temp. 0-50
Operating humidity Max. 80% RH
Zero adjust function
Hold function
Weight kg 12
Voltage data 230 V, 50 Hz
l included ¡ available/optional
13 mm LCD
0-2200
l
l
0.01 % FS
Standards
ASTM D 1003
EN587
ISO7686
Lux
Lux
C
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
21
n stainless steel tank
n Integrated cooling unit
n Sample cage lift
Standard equipment
Methylene chloride tester High temperature
constancy
Maximum health
protectionStandards
EN 580
ISO 9852
The methylene chloride tester is used to determine the re-sistance of
PVC pipes to dichloromethane at a specifi ed temperature.
Description
Temperature range °C 10 – 30
Regulating accuracy °C ±0.5
Cooling Integrated cooling unit
Test fl uid Approx.25 l, dichloromethane CH2Cl
2* Density
at 20 °C: 1.32-1.33 g/cm3
Height of medium level mm Approx. 100
Height of water layer mm Approx. 100
Controller PID controller
Permissible ambient temperature °C +5 to +35
Permissible relative humidity Max. 70%, non-condensing
Width (internal) mm 480
Depth (internal) mm 300
Height (internal) mm 360
Width (external) mm 610
Depth (external) mm 540
Height (external) mm 850
Weight kg 80
Voltage data 230 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
22
A key attribute of plastic is its resistance to environmental stress cracking. It can be tested easily with AHP ESCR tester.
It consists of:
> Test bath with digital temperature control
>sample holder
>Punch and die
> Notch device
> Bending clamp
>Sample transfer tool
>10 glass tubes and rubber plugs
Description
ESCR Tester Constant test
temperatures
water circulation Precise PID temperature control
Standards
ASTM D 1693
Temperature range °C 50 (method A/B), 100 (method C)
Temperature accuracy ±0.5
Temperature and control display Digital
Max. number of test tubes 10
Max. number of samples in test tubes 10
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 770
Depth mm 460
Height mm 380
Weight kg 35
Voltage data 230 V, 50/60 Hz
l included ¡ available/optional
Specification
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
23
DescriptionThis unit is used for performing leak tests on mechanical joints between fittings and
pressure pipes under hydrostatic internal pressure while subjected to bending.
Test chamber for leak test (subjected to internal pressure and bending)
Specifications Test pressure bar Max. 100
Display of pressure Manometer
Sample diameter mm 32 to 80
Sample length 10 x outside diameter
Test temperature °C Ambient temperature
Splash protection l
Endclosure and bending template for each pipe dimension ¡
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 1500
Depth mm 600
Height mm 1600
Weight kg Approx. 200
Voltage data 230/400 V, 50 Hz
l included ¡ available/optional
Pneumatic Standards
EN 921
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
24
DescriptionThis unit is used for performing leak tests on mechanical joints between fittings and pressure pipes under hydrostatic external pressure.
Test chamber for leak test (subjected to external pressure)
Specifications Test pressure bar Max. -2 bars
Display of pressure 7" Touch
Sample diameter mm 32 to 125
Sample length 1000
Test temperature °C Ambient temperature
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 800
Depth mm 600
Height mm 1600
Weight kg Approx. 100
Voltage data 230/400 V, 50 Hz
l included ¡ available/optional
Standards
EN 911
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
mm
Pneumatic type 7" Touch Monitor Thermal Printer USB Data Out
25
Standards
ISO 75 ASTM D 1525
ISO 306
ASTM D 648
The tester is used to determine the Vicat softening temperature and the
heat deflection temperature under load for plastics and thermoplastics.
Description
Vicat/HDT tester Pneumaticlifting platform
PID Temperaturecontroller
Number of stations 2
Temperature range °C +20 to +200
Resolution K ±0.1
Inductive distance measurement
Distance measurement accuracy mm 0.01
Temperature gradient K/h 50, 120
Variable HDT span mm 64 or 110
Bath volume l Approx. 13
Heat transfer oil
Software
PC
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 580
Depth mm 700
Height mm 500
Weight kg 78
Voltage data 230/240 V, 50/60 Hz
included available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
26
Dripping Pipe and Tape Tester 19" Display Auto Flow
MeasurementStandards
ISO9261
In order to assure the quality of the manufactured drip
emitting pipe, in an efficient and accurate manner, AHP
offers AHP-DPT unit is made all-round of stainless-steel,
is designed robust, with fast-connectors & easy
positioning of the measuring elements, making the testing
bench suitable for the most demanding production floor.
The AHP-DPT is equipped with 10 precise measuring
elements, resulting with high precision and reliable test
measurements according to ISO9261 standard.
Description
Type 10 measuring stations
Pipe diameter mm 12-22
Pipe wall thickness 0.15-1.2mm
Dripper Flow Range L/h 0.4-8
Pressure Range 0.3-6
Burst Test
Voltage data 230 V, 50/60 Hz
l included ¡ available/optional
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
The unit performs several tests, such as flow at nominal pressure, burst tests and more. These are easily selected
and monitored during production with user-friendly interface.
Automatic transfer of the product info from the production line can be chosen and QC reports can be easily made.
mm
bar
l
27
DescriptionAHP Offers broad range of testing equipment for pvc conduit pipes including impact, bending, flame,
electrical resistance , .... testing equipment.
Bending tester is used to check the quality of pvc conduitcs where it is need for bending. Based on
standard it should not break during this testing. metal srping goes inside the conduit and using
pneumatic machine the pipe bends for 180 degress.
Electrical PVC Conduit Bending Tester
Specifications
Force type Pneumatic
Size change Manual
Springs mm 16,20,25,32
Rollers Aluminum
Pipe sizes
Speed adjustment
Air input 8 bars-6mm connector
Guide shafts Chrome plated
Weight kg 50
Voltage data 230 V, 50 Hz
l included ¡ available/optional
16,20,25,32
Air flow valve
mm
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
IEC 61386
28
DescriptionIt is a simple and reliable option for checking the uniform structure of moulding compounds. By flowing
a defined mass of powder or grain through a funnel, bulk density can be measured.
Bulk Density Tester
Specifications
V1
V2
V3
V4
ISO 60ASTM D 1895
method A
ASTM D 1895
method B
ASTM D 1895
method C
Funnel with spring-loaded trap cm³ 200 235 1000
Measuring cup capacity cm³ 100 ± 0,5 100 ± 0,5 400 ± 2 1000 ± 20
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width mm 200 190 190 190
Depth mm 160 160 160 160
Height mm 250 260 560 560
Weight (approximate) kg 2.6 2.6 2.6 4.7
l included ¡ available/optional
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
ISO 60
ASTM D 1895
29
DescriptionAHP Notch milling device is used to make Izod/Charpy nothed on the samples accordign to the related
standards.
Izod/Charpy Notch Milling Device
Specifications
Depth adjustment Manual
Depth reading Micrometer
Tool movement Handle
Maximum samples 5
Guide shafts
Weight kg 30
l included ¡ available/optional
Chrome plated
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Standards
ISO 179
ISO 180
30
DescriptionThe temperature cycling tester is designed to determine the resistance of
thermoplastic pipe network and connections consisting of stiff or flexible parts to
alternating thermal shock. This applies to pipe systems intended to be used for
conveying hot and cold pressurized water.
Thermal cycling test unit According to EN 12293 | ISO 10508
Pressure range bar 4 - 16
Temperature cold range °C 15 - 30
Temperature hot range °C 50 - 95
Temperature accuracy °C at 95 °C ±2 °K, at 20 °C ±4 °K
Adjustment accuracy of controller °C ± 0,5
Pressure accuracy % 1 % of full scale
Flow rate accuracy % ± 5%
Max. number of cycles each test 90
hot and cold water tank capacity l 500
Pumps capacity at 10 bar m³/h 12
Pumps capacity at 16 bar m³/h 10
Heat exchanger for connection to external cooling water supply l
External cooling unit ¡
Controller PLC Based+Desktop PC
Permissible operating ambient temperature °C +5 up to +25
Max. relative air humidity 70 %, noncondensing
Power supply voltage 230/400 V, 50 Hz
Max. number of test lines 3
Sliding doors l
l inclusive ¡ available/optional
Specification
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
31
Thermal cycling test unit
* High-quality components guarantee high reliability* PLC-controlled, self-learning PID pressure regulation* Constant test temperatures* high pressure accuracy* Precise flow regulation* Convenient visualisation via PC control* Windows based software* Large sliding doors of sample cabin guarantee easy access to the testchamber * Sampl Rack for easy installation* Data logging software included* Manual tensioning system with digital load display to apply initial tensilestress
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
32
DescriptionThe forced air oven is used to condition samples for tests such as longitudinal reversion
and as a drying oven (e.g. for water absorption, etc.).
Forced air oven
Specifications
Max. operating temperature °C 250
Spatial temperature constancy °C ±1.5
Temporal temperature constancy °C ±0.3
Digital temperature display l
Usable space l 55
Stainless steel cabin l
Shelves 2
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width (internal) mm 470
Depth (internal) mm 310
Height (internal) mm 440
Width (external) mm 620
Depth (external) mm 450
Height (external) mm 730
Weight kg 40
Voltage data 230 V, 50 Hz
l included ¡ available/optional
Standards
ISO 2505
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
0.1 °C Resolution Japanese Controller
33
The circometer is the easiest way of determining the outside diameter of pipes ranging from 15 to 630 mm.
Description
Circometer
Standards
ISO 3126
Specifications
Measuring range mm 15 - 115 50 - 300 300 - 600 100 - 200 200 - 350 300 - 500 500 - 700
Other measuring ranges available on request
Reading accuracy mm 0.05 with vernier scale
Reference temperature °C +20
Operating temperature °C +10 to +30
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
34
DescriptionIt is used for ash content testing in plastic materials.
High Temperature Furnace
Specifications
Max. operating temperature °C 1200
Spatial temperature constancy °C ±2
Temporal temperature constancy °C ±1
Digital temperature display l
Usable space l 2.5
Permissible ambient temperature °C +5 to +30
Permissible relative humidity Max. 70%, non-condensing
Width (external) mm 600
Depth (external) mm 500
Height (external) mm 500
Weight kg 50
Voltage data 230 V, 50 Hz
l included ¡ available/optional
Standards
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
1 °C Resolution Japanese Controller German Heating Element
35
DescriptionThe AHP calibration sleeves are practice-oriented solutions to optimize the plastic pipe Extrusion. It is used for
pipe diameter and ovality adjustment during extrusion process.
> Greater adjustment range with two adjustment points
> Easy handling with high flexibility
> Make larger or smaller adjustments during ongoing production
> Adjustment range for all SDR classes
Adjustable Calibration Sleeves for Pipe Extrusion Lines
Specifications
Data subject to change. All rights reserved.
No.78, A Block, Perlavista Bld., Beylikduzu, Istanbul, Turkey
www.ahp-makina.com
Sea Water ResistantAlloy
Two Point Adjustment
Wide Adjustment Range
36
37
38