2018-19 AIR QUALITYRENTAL SOLUTIONS
APPLICATION GUIDE
www.airflorental.co.uk
ContentsVentilation fans 4-9
Exhaust filters 10-11
Air scrubbers 12-13
Dust extractors 14-15
Air conditioners 16-19
Heaters 20-23
Dehumidifiers 24-27
Refrigerant pumps 28-29
Protecting healthand the environment
We do what we do so that you do what you do.
We address air quality issues in the workplace with on-demandtemporary rental solutions, so you can breathe again.
Our focus is on you and your needs, maintaining sustainable andsafe-working environments, protecting workers’ health andincreasing productivity.
We take time and care to listen to what you are saying to us sothat we understand your challenges, which means that everyAirflo solution is simple and effective.
on-demandrental solutions
0800 289 191 [email protected] www.airflorental.co.uk
for temporaryair quality management
0800 289 191 [email protected] www.airflorental.co.uk
HIGH PRESSUREVENTILATION FORMINES, SHAFTS ANDTUNNELS
0800 289 191 [email protected] www.airflorental.co.uk
High pressure ventilation 5High pressure ventilation High pressure ventilation High pressure ventilation High pressure ventilation
For ventilation of shafts and tunnels, the HP-series centrifugal ventilatorsare inverter-driven for optimum performance and efficiency.
Model Maxvolume
m³/s
Maxpressure
Pa
Outletmm
Powersupply
Dimensionsmm
WeightKg
HP80 12.5 2500 500 x 1000 415V22KW
H: 2000W: 1500L: 2660
650
HP70 9 1000 600 415V15KW
H: 1900W: 1500L: 1300
550
HP60 5 1000 600 415V11KW
H: 1900W: 1100L: 1500
400
HP50 2.6 1000 450 415V4KW
H: 1500W: 850L: 1300
300
Attenuators and duct adaptors available, also flexible and rigid ducting options withfittings and suspension systems.
0800 289 191 [email protected] www.airflorental.co.uk
MEDIUM PRESSUREVENTILATION FORTUNNELS ANDCONFINED SPACES
0800 289 191 [email protected] www.airflorental.co.uk
Medium pressure ventilation 7
For high volume at medium pressure, the TX-series multi-stage contra-rotating axial fans are inverter-driven and fitted with silencers foroptimum performance.
Model Maxairflowm³/s
Maxpressure
Pa
Outletdiameter
mm
Powersupply
Dimensionsmm
WeightKg
TX125 18 1080 1250 415V11KW
H: 1425W: 1380L: 4120
720
TX80 9 720 800 415V8.0KW
H: 1080W: 890L: 2500
280
TX63 4.5 600 630 415V3.0KW
H: 800W: 710L: 2400
220
Flexible and rigid ducting options available including fittings and suspension systems
Medium pressure ventilation Medium pressure ventilation Medium pressure ventilation Medium pressure ventilation
0800 289 191 [email protected] www.airflorental.co.uk
LOW PRESSUREVENTILATION FORWORKSHOPS, FACTORIESAND WAREHOUSES
0800 289 191 [email protected] www.airflorental.co.uk
Low pressure ventilation 9
For high volume at low pressure, the AX-series single stage axial fansoffer a wide range of options for maximum flexibility.
Model Maxairflowm³/s
Maxpressure
Pa
Outletdiameter
mm
Powersupply
Dimensionsmm
WeightKg
AX125 18 450 1250 415V5.5KW
H: 1425W: 1380L: 860
260
AX80 9 300 800 415V4.0KW
H: 1080W: 930L: 560
90
AX63 4.5 250 630 415V/110V1.5KW
H: 900W: 800L: 635
57
AX40 1.75 500 400 110/240V1.7KW
H: 490W: 470L: 540
27
AX30 1 343 300 110/240V0.52KW
H: 400W: 370L: 440
14
Flexible and rigid ducting options available including fittings and suspension systems
For high volume at low pressure, the AX-series single stage axial fans
0800 289 191 [email protected] www.airflorental.co.uk
ULTRA-FINE GRADEDIESEL PARTICULATEFILTERS FOR PLANTAND MACHINERY
HT-series exhaust filters are designed for permanent use on dieselengines, effectively removing over 99% of diesel particles as small as0.4µm along with the mutagenic, cancerous and allergy-producingsubstances attaching to them.
Model Maxvolumem³/min
Maxtemp
°C
Hoseconnection
mm
Dimensionsmm
WeightKg
HT35 35 250 125 Ø: 500L: 795
50
HT20 20 250 90 Ø: 370L: 795
34
HT10 10 250 90 Ø: 370L: 475
23
For intermittent use
L20 n/a 300 50 Ø: 200L: 195
7
P15 n/a 200 50 Ø: 125L: 195
2
A range of high temperature flexible hoses and stainless steel tubing, bends, fittingsand fixings are available for easy installation.
0800 289 191 [email protected] www.airflorental.co.uk
Diesel Exhaust Filters 11
0800 289 191 [email protected] www.airflorental.co.uk
PERFORMANCEAIR SCRUBBERSFOR HIGH VOLUMESPACE CLEANING
For removal of airborne dusts and irritants, these powerful air scrubbersmay be used for re-circulation of air or for holding segregated areasunder either negative or positive pressure,
Model Maxairflowm³/hr
Maxpressure
Pa
Duct diametermm
Powersupply
Dimensionsmm
WeightKg
E320 5,400 1,250 450 110V3.0KW
H: 790W: 670L: 1030
73
MX400 3,600 400 315 110/240V550W
H: 690W: 620L: 750
15
A 2000 2,000 800 200 115V505W
H: 1020W:560L: 700
30
A 1000 1,000 600 125 115V210W
H: 380W:340L: 500
13
HEPA H13 filtration, tested and certified to 99.95% efficiency at the 0.15-0.3µm range.NOT CERTIFIED FOR HANDLING ASBESTOS
0800 289 191 [email protected] www.airflorental.co.uk
Air scrubbers 13
0800 289 191 [email protected] www.airflorental.co.uk
HIGH VACUUMDUST COLLECTORSFOR ON-TOOLEXTRACTION
For efficient at-source collection of dust, Husqvarna offers a range ofpowerful dust collectors complemented by a range of shrouds andfittings. The Longopac® bag hose system ensures simple, dust-free bagchanging.
Model Maxairflowm³/hr
Maxvacuum
kPa
Filters Powersupply
WeightKg
T 10000 900 30 3 415V11KW
336
T 7500* 600 28 2 415V5.5KW
206
S 36 600 24 2 110V3.6KW
47
S 26* 400 22 2 110V2.4KW
47
S 13* 200 22 1 110V1.2KW
29
W 70P 200 22 n/a 110v1.2KW
45
HEPA H13 filtration, tested and certified to 99.95% efficiency at the 0.15-0.3µm range.NOT CERTIFIED FOR HANDLING ASBESTOS
*Certified H-type extractor
0800 289 191 [email protected] www.airflorental.co.uk
Dust Collectors 15
For efficient at-source collection of dust, Husqvarna offers a range of
Industrial high-capacity packaged air conditioning units for process andpersonnel cooling. Configured for simple, fast installation and operationfor breakdowns, scheduled maintenance and supplementary cooling.
Model Coolingcapacity
KW
Air flowm³/hr
Outletdiameter
mm
Returnair
Powersupply
Dimensionsmm
WeightKg
MAC650 65 17,100 1 x 600 Option 415V23.8KW
H: 1,750W: 2,400L: 4,850
1900
DX40P 40 13,500 1 x 600 Option 415V13.9KW
H: 1,600W: 1,620L: 3,150
770
MAC340 34.5 7,560 2 x 300 Option 415V12.0KW
H: 1,550W: 1,760L: 3,050
670
MAC250 25.5 5,580 1 x 450or
2 x 300
Option 415V9.1KW
H: 1,400W: 1,460L: 2,800
560
MAC170 16.9 3,560 1 x 300 Option 415V5.5KW
H: 1,150W: 990L: 1,950
285
30H 10.0 1,500 1 x 300 No 415V4.0KW
H: 1,240W: 680L: 1,100
180
0800 289 191 [email protected] www.airflorental.co.uk
Package DX Units 17
0800 289 191 [email protected] www.airflorental.co.uk
MOBILE AIRCONDITIONERS FORPERSONNEL ANDOFFICE COOLING
Heavy duty mobile air conditioners for instant spot-cooling in offices andindustrial environments.
Model Coolingcapacity
KW
Air flowm³/hr
Outletdiameter
mm
Returnair
Powersupply
Dimensionsmm
WeightKg
MC27 7.9 1,870 No 240V2.65KW
H: 1,170W: 825L: 665
105
15SF 4.4 800 2 x 150 No 240V1,7KW
H: 1,054W: 407L: 670
76
SC14 4.1 600 No 240V1,7KW
H: 740W: 300L: 480
31
KY32 3.2 330 No 240V1,2KW
H: 856W: 450L: 370
45
0800 289 191 [email protected] www.airflorental.co.uk
Air Conditioners 19
Heavy duty mobile air conditioners for instant spot-cooling in offices andindustrial environments.Heavy duty mobile air conditioners for instant spot-cooling in offices andHeavy duty mobile air conditioners for instant spot-cooling in offices andHeavy duty mobile air conditioners for instant spot-cooling in offices and
0800 289 191 [email protected] www.airflorental.co.uk
INDUSTRIAL ELECTRICFAN HEATERS FORWORKSHOPS, FACTORIESAND WAREHOUSES
0800 289 191 [email protected] www.airflorental.co.uk
Electric Heaters 21
For rapid and efficient space-heating, electric heat is dry and clean.
Model Heatoutput
KW
Maxairflowm³/hr
Ductingmm
Powersupply
Dimensionsmm
WeightKg
FF29 29 2040 300up to 15m length
415V32A
H: 570W: 400L: 520
36
DE95 18 1520 300up to 5m length
415V28A
H: 570W: 410L: 470
32
80T 15 1000 150up to 15m length
415V24A
H: 470W: 530L: 980
27
HE6 6 340 n/a 415V/10A240V/25A
H: 475W: 363L: 375
7
HE3 3 250 n/a 240V/12.5A110V/27A
H: 355W: 363L: 350
5
0800 289 191 [email protected] www.airflorental.co.uk
INDIRECT OIL-FIREDHEATERS FOR CLEANAND EFFICIENTSPACE HEATING
0800 289 191 [email protected] www.airflorental.co.uk
Oil Space Heaters 23
Indirect oil-fired heaters
Model Heatoutput
KW
Maxairflowm³/hr
Outletdiameter
mm
Powersupply
Dimensionsmm
WeightKg
IMA200 200 10000 600 230V15A
H: 1520W: 910L: 2710
425
IMA150 150 7400 500 230V5.7A
H: 1510W: 840L: 2000
332
IMA111 110 5800 500 230V4.4A
H: 1340W: 780L: 1790
278
Direct oil-fired heaters
T80 93 2150 0 230V3.6AV
H: 900W: 630L: 1730
85
Flexible and rigid ducting options available including fittings and suspension systems
0800 289 191 [email protected] www.airflorental.co.uk
REFRIGERATIONDEHUMIDIFIERS FORBUILDING AND INDUSTRIALDRYING
0800 289 191 [email protected] www.airflorental.co.uk
Refrigeration Driers 25
Refrigeration dehumidifiers are economical to run and are most effectivein warm, damp environments.
Model Air flowm³/hr
Extractionat 20/70ltr/24hr
Room Volumemax m³
Powersupply
Dimensionsmm
WeightKg
PD600 750 59 600 240V/110V1.1KW
H: 1020W: 630L: 585
65
TBD6 500 31 350 240V/110V0.75KW
H: 520W:645L: 830
51
PD300 380 31 300 240V/110V0.65KW
H: 820W: 363L: 365
38
0800 289 191 [email protected] www.airflorental.co.uk
Desiccant Driers 27
Desiccant drying is a chemical dehumidifying process, especially efficientat low temperatures and low humidity levels, particularly suited toprocess drying
Model Airflowm³/hr
Extractionat 20/70ltr/24hr
Process airductmm
Powersupply
Dimensionsmm
WeightKg
M120 120 20 Inlet: 80Outlet: 100
110V1.3KW
12A
H: 425W: 425L: 481
29
M200R 200 23 Inlet: 80Outlet: 100
110V1.3KW
12A
H: 900W: 460L: 600
31
MD300 285 45 Inlet: grilleOutlet: 160
415V2.1KW
3A
H: 950W: 420L: 800
78
M650 650 103 Inlet: 205Outlet: 205
415V6.7KW
10A
H: 950W: 685L: 1220
105
M1200 1,200 164 Inlet: 205Outlet: 205
415V8.9KW
13A
H: 1050W: 700L: 1300
301
M5250 5,250 800 Inlet: 305Outlet: 305
415V52KW77A
H: 1440W: 1280L: 2161
1050
0800 289 191 [email protected] www.airflorental.co.uk
LARGE VOLUME LIQUID& GAS REFRIGERANTRECLAIM PUMPS
0800 289 191 [email protected] www.airflorental.co.uk
Refrigerant Reclaim Pumps 29
Professional heavy duty equipment for high capacity refrigeranthandling, saving cost and time. Only F-Gas certified engineers arequalified to use this equipment.
Model Reclaimcapacity
kg/hrNotes
Powersupply
Dimensionsmm
WeightKg
AP200 20055
Auto change-over liquid-
vapour
240V1.48KW
H: 930W: 480L: 880
92
OLE70 7020
Oil-less 240V0.37KW
H: 420W: 250L: 280
30
E55 -55
Vapour only 240V1.3KW
H: 902W: 420L: 450
54
E25 -25
Vapour only 240V0.85KW
H: 720W: 330L: 310
30
www.airflorental.co.uk
Protecting healthand the environment
On-demand rental solutions fortemporary air quality management
Copyright © 2018 Airflo Envirorental Ltd All Rights Reserved
Fresh Air. Anywhere.
Airflo Envirorental LtdBank StreetDoncasterDN1 3RB
01302 [email protected]
www.airflorental.co.uk