2020
P R O D U C T C ATA LO G U E
2
A B O U T T H E D A N T H E R M G R O U P
Control your climate
The Dantherm Group is a leading provider of climate control products and solutions. The group companies have more than 60 years of experience in designing and manufacturing high quality and energy efficient equipment for heating, cooling, drying and ventilation for a wide range of mobile and fixed applications.
Every year Dantherm Group uses significant resources on product development to stay in the forefront and are constantly adapting the products to changing market demands and legislation.
The Dantherm Group has strong brands with well-established market positions in the mobile, pool, commercial/industrial and residential markets.
Dantherm Group customers benefit from our comprehensive knowledge base and the experience and expertise that we have gained from more than three million climate control
products and solutions sold worldwide.
Global reach
The Dantherm Group is headquartered in Skive, Denmark and has companies in Norway, Sweden, United Kingdom, Germany, France, Switzerland, Italy, Spain, Poland, Russia, China and United Arab Emirates and a global distribution network.
In 2016 the Dantherm Group was acquired by the Swedish equity fund Procuritas Capital Investors V LP – a strong owner with the ambition to continue the development and growth of the company.
3
P R O D U C T C ATA LO G U E
I N D E X
POOL
POOL WATER HEAT PUMPS – AIR SOURCE
DOMESTIC ............................................................................................ 10
COMMERCIAL .................................................................................... 14
POOL WATER COOLING – AIR COOLED HEAT PUMPS
DOMESTIC AND COMMERCIAL ............................................. 18
COMMERCIAL .................................................................................... 19
POOL DEHUMIDIFIERS
WALL MOUNTED ............................................................................. 22
FLOOR STANDING ........................................................................... 24
POOL AIR HANDLING UNITS
AA 300/500 .......................................................................................... 28
VARIHEAT SYSTEMS ........................................................................ 29
DELTA SYSTEMS ................................................................................ 32
HRD SYSTEMS .................................................................................... 35
COMMERCIAL & INDUSTRIAL
WATER HEATING – AIR SOURCE HEAT PUMPS
DOMESTIC ............................................................................................ 38
COMMERCIAL .................................................................................... 39
WATER HEATING – WATER SOURCE HEAT PUMPS
COMMERCIAL .................................................................................... 41
WATER COOLING – AIR COOLED HEAT PUMPS
COMMERCIAL ................................................................................... 44
TECHNOLOGIES
REFRIGERANT VS DESICCANT ................................................. 48
DEHUMIDIFIERS
WALL MOUNTED ............................................................................. 49
FLOOR STANDING ........................................................................... 52
HIGH CAPACITY DEHUMIDIFIERS
FLOOR STANDING ........................................................................... 53
DUCTED ................................................................................................. 56
HIGH TEMPERATURE PROCESS DRYING ........................... 57
MOBILE
PORTABLE AIR-CONDITIONING
COMMERCIAL .......................................................................................4
AIR-CONDITIONING
INDUSTRIAL ............................................................................................5
PORTABLE REFRIGERANT DEHUMIDIFIERS
COMMERCIAL .......................................................................................6
INDUSTRIAL ............................................................................................7
4
Accessories
Specifications Units ACT 7 (EU) ACT 7 (UK)
Performance*Cooling capacity kW 7.0 7.0Power supply V/Hz 230/1ph/50 230/1ph/50Fuse A 16 13Nominal running current A 11.2 11Nominal power consumption kW 2.6 2.5Air flow (variable) m3/h 930-1310 930-1310Sound level @ 3m dB(A) 56 56Operating range (room) oC 8-35 8-35Operating range (outdoor) oC 0-40 0-35Product size (h x w x d) mm 1070 x 852 x 420 1070 x 852 x 420
Hex size (h x w x d) mm 520 x 560 x 280 520 x 560 x 280
Weight kg 117 117
* Outside conditions 28°C/60% RH
AC T 7
Features
� Whole-room cooling without the need to continually exhaust internal air.
� Smooth, low-sound operation with low energy consumption.
� Resistant to wear and tear even when moved and reinstalled several times.
� No cooling knowledge or special training required to install the unit.
� Easy power connection with standard 230V CEE 7/7 power supply (EU only).
� Easy-to-clean surfaces due to high-gloss painting.
� Stepless, variable fan speed for improved control and user comfort.
� Direct air towards desired spot using the adjustable grille.
� Easy to move both the indoor and outdoor unit. Easily fits through narrow doors and in elevators.
� Quick-connect cooling line connectors make installation easy and eliminate the need to recharge water lines.
� Slim water and glycol hose connection eliminates need for large air ducts, meaning that only a small outdoor opening is required.
� Indoor and outdoor units can be placed up to 30 metres apart and at different heights (up to 10 metres) for increased flexibility.
� Outdoor unit can stand on ground or hang outside building (chains included).
Applications
� Rental companies
� Event organisations
� Data centres and server rooms
� Facility management companies
� Retail premises
� Small workshops
� Industrial kitchens
� Fitness rooms
� Temporary cold room cooling
The hex unit features a speed controlled EC fan (non-UK only) that automatically adjusts to differing outside air temperatures so that the ACT 7 is always operating at its best efficiency.
Additional 5m or 15m line sets (maximum length 30m per unit)T-split for connection of two outdoor units to one indoor unit for extended operational range ≥ 40°CDuct spigot kitForklift guides
P O R TA B L E A I R - CO N D I T I O N I N G
CO M M E R C I A L
5
TO
CO
OL
Features
�High capacity space chiller
�Rapid installation and flexibility of positioning
�No external refrigerant connections required
�No external ventilation or ductwork to exterior required
�Fully automatic operation
�Robust construction
�Ducted cool air when required
�Ideal for locations requiring a low temperature storage facility
Applications
� Food packing and process areas
� Factories and workplaces
� Industrial processes
� Warehouses storing perishable goods
� Emergency back-up for cold stores
� High capacity cooling for social events
Specifications Units ACT 35
Power supplyStarting currentMax. running currentMin. generator required
V/HzAA
KVA
380-415/3ph/501353730
Product size (indoor) (w x d x h)Weight
mmkg
1730 x 1250 x 1600497
Product size (outdoor) (w x d x h)Weight
mmkg
1196 x 1032 x 1616360
AC T 35
KW C
OO
LIN
G (A
IR)
M3
ROOM TEMPERATURE °C
(ASSU
MES STD
‘U’ VA
LUES FO
R APPLICATIO
N)
1,000
800
600
400
200
0-15-10-5051015202530
0
5
10
15
20
25
30
35ACT35
A I R - CO N D I T I O N I N G
I N D U S T R I A L
6
Features
� Robust
� Easy to use
� Can be cleaned by jet-wash
� Operation in temperatures down to 3°C – hot gas defrost supplied with units
� Dual voltage – units can be supplied with 110/240 volt option
� Non-marking wheels – no tyre marks left on floors
Applications
� Building industry, restoration work
� Moisture removal in new houses
� Drying during construction
� Water removal after painting
Specifications Units PD 300
Maximum capacity l/24h 53
Capacity (20°C/70% RH) l/24h 31
Capacity (30°C/80% RH) l/24h 46
Air flow m³/h 380
Power supply (AX model) V/Hz 230/1ph/50
Dual voltage option (AJX model) V/Hz 110/230/1ph/50
Recommended size of dual voltage transformer VA 800
Recommended supply fuse A 13
Nominal power consumption kW 0.65
Product size (h x w x d) mm 850 x 510 x 480
Weight kg 45
P D 300
Options
� Condensate pump kit, humidistat, hours-run meter
Note: European version of the Porta-Dry is called a DHM
P O R TA B L E R E F R I G E R A N T D E H U M I D I F I E R S
CO M M E R C I A L
7
TO
DR
Y
Applications
� Industrial and commercial
� Preservation
� Sewage treatment, waterworks
� Agriculture
� Data centres
P D 1500
Specifications Units PD 1500
Maximum capacity l/24h 300Capacity (20°C/60% RH) l/24h 100Capacity (30°C/80% RH) l/24h 220Air flow m3/h 2500Sound level @ 3m dB(A) 58Supply (no neutral required) V/Hz 400/3ph/50Power input kW 2.7Nominal power consumption A 6.75Recommended fusing A 16Required starting current A 30Recommended room size construction drying m3/m2 1700/600Product size (l x w x h)Weight
mmkg
1100 x 700 x 1313130
Features
� Plastisol coated galvanised steel cabinet
� Self contained with fully automatic operation
� Integral humidistat
� Polyester coated evaporator and condenser
� Usable from 3°C
� Ultra-powerful compressor
� High lift condensate pump
� Hot gas defrost for low temperature operation
� In-built transformer so power supply neutral not required
� Service-optimised construction for quick cleaning and inspections
� Suitable for connecting to ducted air systems
� Easily exchangeable and washable air filter
P O R TA B L E R E F R I G E R A N T D E H U M I D I F I E R S
I N D U S T R I A L
T H E C H A L L E N G ETo provide a solution to temperature control which will reliably and economically heat or cool a swimming pool, regardless of ambient air temperature and location.
Enjoyable swimming
Dependable swimming pool temperature control is a key feature to enjoyable swimming.
For a swim to be refreshing and invigorating the pool water must be the right temperature for the swimmer, regardless of the influence of seasonal weather.
Winter heating
During winter, swimming pools continually evaporate water and radiate heat. The combination of these factors causes heat loss which must be replaced through a heater if comfortable water temperatures are to be maintained.
Summer cooling
During summer, swimming pools are subjected to massive solar gain. Coupled with high ambient humidities which prevent pools from cooling through evaporation, swimming pool water will become uncomfortably hot unless dynamically cooled.
COOL GASHOT GAS
HEATEXCHANGER
EVAPORATOR
COLD LIQUIDREFRIGERANT
HIGH PRESSURE SIDE
CONDENSEDREFRIGERANT
COMPRESSOR
EXPANSIONVALVE
AMBIENTAIR
LOW PRESSURE SIDE
WATER OUT
WATER IN
THE HEAT PUMP CYCLE
The heat pump cycle
8
Our products
Calorex heat pumps are specifically designed for swimming pool heating and cooling.
This means that all components used in their construction are designed to give maximum efficiency and reliability at swimming pool conditions, even in the toughest climates.
Why heat pumps?
Heat pumps are recognised as the most sustainable way to dynamically heat or cool swimming pool water saving both energy and operating costs.
Unlike electric flow heaters and boilers that can only provide pool heating. Calorex heat pumps will automatically either heat or cool your pool without the need for additional equipment.
As an added bonus, a Calorex heat pump will produce up to five times the energy it consumes, dramatically reducing the energy consumption of your swimming pool.
Rapid installation, flexible operation
Fully self-contained units, Calorex heat pumps easy to install and when it comes to operation, units offer quiet, reliable and safe performance.
Year round operation
Calorex heat pumps have various operating temperatures and will suit different environments and climates.
T H E S O LU T I O NThe answer to this problem is the Calorex range of purpose built heat pumps, chillers and heat cool systems for use in any size pool and plant room.
Benefits
�Up to 400% operating cost and carbon saving against direct electric heaters
�Up to 47% operating cost saving against fossil fuel boilers
�Up to 60% carbon saving against fossil fuel boilers
�No flues or fuel storage tanks
�Simple installation and long service life
�Minimal maintenance
�Easy to retrofit to existing swimming pool systems
9
Calorex heat pumps can be used for either heating a pool, cooling a pool or both making them the ultimate temperature control product.
10
Features
�Quiet, aesthetically pleasing design
�Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
�ABS cabinet
�Scroll or Rotary compressor
�Titanium heat exchanger
�Reverse cycle defrost – operation to -10°C air temperature
�Can heat water to 40°C
�Multifunction operation functions can be set to heating, heat/cool and cooling
�‘Smart’ pool pump control
�Condensate collection
�Water flow switch
�Three year limited parts supply warranty, first year includes labour
�Designed by Calorex in the UK
Applications
�Outdoor pools
�Private pools
�Spa pools
�Above ground pools
�Wellness centres
�Therapy pools
CO M - PAC +
Options
�Winter protection cover
Output and input calculated @ 26°C water temperature
Specifications Units CPT 6Y CPT 8Y CPT 12Y CPT 15Y CPT 20Y
Air temperature rangeWater temperature range
Output @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ +5°C/100% RH ambientInput @ +5°C/100% RH ambient
COP 15°C ambientPower supplyMax. power inputMax. currentRefrigerantMin./max. pressureAir flowSound level @ 3mSound level @ 10mProduct size (w x d x h)Weight
°C°C
kWkW
kWkW
kWkW
V/HzkWA
Pam3/hdB(A)dB(A)mmkg
-10-3510-40
7.21.3
5.71.2
4.71.1
4.75230/1ph/50
2.3310.59R32
1.5/4.152200
3728
654 x 405 x 96851
-10-3510-40
8.61.6
6.81.4
5.11.3
4.85230/1ph/50
2.7112.32R32
1.5/4.152000
3829
654 x 405 x 96853
-10-3510-40
12.42.2
9.82.0
8.21.9
4.90230/1ph/50
3.8317.41R32
1.5/4.153900
3930
709 x 490 x 113072
-10-3510-40
17.23.1
13.92.9
10.62.7
4.79230/1ph/50
5.9427.00R32
1.5/4.153800
3930
709 x 490 x 113093
-10-3510-40
22.84.5
18.54.1
14.13.9
4.60400/3ph/50
7.5012.30R32
1.5/4.157000
4132
1299 x 520 x 809117
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
D O M E S T I C
11
TO
HE
AT
TO
CO
OL
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
D O M E S T I C
Features
�Average COP 9.7 = +2 x more efficient than on/off heat pumps
�Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
�Inverter heat pump
�Increased range of power ratings from 8 to 25kW
�9-11 dB(A) sound reduction than on/off heat pump, with ‘Whisper Mode’
�27% to 46% reduction in size of dimensional footprint
�Increased operating range
�Multifunction operation functions can be set to heating, heat/cool and cooling
�Soft start-up
�Aluminium alloy
�Built-in Wi-Fi module
�Designed by Calorex in the UK
Applications
�Outdoor pools
�Private pools
�Spa pools
�Above ground pools
�Wellness centres
�Therapy pools
Options
�Remote LED control kit
�Winter protection cover
I - PAC 16 A L X
I - PAC 16 A L X
12
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
D O M E S T I C
Specifications Units IPT 8ALX IPT 12ALX IPT 16ALX IPT 22ALX
Air temperature range °C -5-43 -5-43 -5-43 -5-43Water temperature range °C 12-40 12-40 12-40 12-40Performance – air 27°C 80% RH, Water 27°CHeating capacity kW 9.5 13.0 20.0 25.0COP range 13.2-5.4 13.5-5.6 13.5-5.7 13.8-5.8Average COP at 50% speed 8.9 9.7 9.3 9.6Performance – air 15°C 70% RH, Water 26°CHeating capacity kW 7.0 9.5 13.5 17.0COP range 6.9-4.2 7.0-4.0 7.0-4.2 7.2-4.0Average COP at 50% speed 6.3 6.1 6.3 6.4Performance – air 35°C 80% RH, Water 28°CCooling capacity kW 3.9 5.2 7.4 9.4Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50 230/1ph/50Rated input power kW 0.03-1.79 0.40-2.38 0.57-3.21 0.69-4.25Rated input current A 1.38-7.58 1.82-10.80 2.60-14.61 3.16-19.32Maximum input current A 9.5 12.5 19.5 20.0Water flow m3/h 3.0-5.0 4.0-6.0 7.0-10.0 10.0-12.0Water connection mm2 1½" or 50mm 1½" or 50mm 1½" or 50mm 1½" or 50mmCompressor Inverter Inverter Inverter InverterCondenser Titanium Titanium Titanium TitaniumR32 gas weight g 600 900 1100 2000Sound level @ 10m dB(A) 19.6-31.5 21.9-32.0 24.3-36.1 24.9-36.7Sound level @ 1m dB(A) 39.6-51.5 41.9-52.0 44.3-56.1 44.9-56.7Product size (w x d x h) mm 864 x 359 x 648 864 x 359 x 648 954 x 359 x748 1084 x 429 x 948Net Weight kg 47 49 68 90
Specifications Units IPT 12ALY IPT 16ALY IPT 22ALY IPT 22BLY IPT 28BLY
Air temperature range °C -10-43 -10-43 -10-43 -10-43 -10-43Water temperature range °C 12-40 12-40 12-40 12-40 12-40Performance – air 27°C 80% RH, Water 27°CHeating capacity kW 15.0 21.0 27.5 27.5 36.0COP range 15.0-6.6 14.8-6.4 15.0-6.5 15.0-6.8 14.8-6.0Average COP at 50% speed 10.6 10.3 10.3 10.3 10.2Performance – air 15°C 70% RH, Water 26°CHeating capacity kW 11.5 14.5 18.0 18.0 23.9COP range 7.7-4.6 7.1-4.6 7.5-4.6 7.5-4.6 7.5-4.6Average COP at 50% speed 6.4 6.3 6.3 6.3 6.3Performance – air 35°C 80% RH, Water 28°CCooling capacity kW 6.7 9.5 11.9 11.9 16.0Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50 400/3ph/50 400/3ph/50Rated input power kW 0.27-2.28 0.41-3.15 0.48-3.91 0.48-3.91 0.64-5.20Rated input current A 1.17-9.91 1.78-13.69 2.08-17.00 0.69-5.66 0.92-7.53Maximum input current A 13.5 17.0 20.0 7.0 9.5Water flow m3/h 5.0-7.0 8.0-10.0 10.0-12.0 10.0-12.0 12.0-18.0Water connection mm2 1½" or 50mm 1½" or 50mm 1½" or 50mm 1½" or 50mm 1½" or 50mmCompressor Inverter Inverter Inverter Inverter InverterCondenser Titanium Titanium Titanium Titanium TitaniumR32 gas weight g 900 1200 2000 2000 2700Sound level @ 10m dB(A) 20.8-24.5 20.4-33.7 23.0-34.4 23.0-34.4 22.1-34.2Sound level @ 1m dB(A) 40.8-54.5 40.4-53.7 43.0-54.4 43.0-54.4 42.1-54.2Product size (w x d x h) mm 954 x 359 x 648 954 x 429 x 755 1084 x 429 x 948 1084 x 429 x 948 1154 x 539 x 948Net Weight kg 52 68 90 93 120
13
TO
HE
AT
TO
CO
OL
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
D O M E S T I C
Features
�Average COP 9.7 = +2 x more efficient than on/off heat pumps�Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)�Inverter heat pump�Increased range of power ratings from 8 to 25kW�9-11 dB(A) sound reduction than on/off heat pump,
with ‘Whisper Mode’ �27% to 46% reduction in size of dimensional footprint�Increased operating range�Multifunction operation functions can be set to heating and cooling�Soft start-up�ABS alloy�Designed by Calorex in the UK
Options
�Winter protection cover
V - PAC 12 A L X
Specifications Units VPT 12ALX VPT 16ALX VPT 22ALX
Air temperature range °C 0-43 0-43 0-43Water temperature range °C 8-40 8-40 8-40Performance – air 27°C 80% RH, Water 27°CHeating capacity kW 14.11 18.5 24.4COP range 13.5-6.28 13.5-6.03 13.5-5.14Average COP at 50% speed 9.7 9.3 8.8Performance – air 15°C 70% RH, Water 26°CHeating capacity kW 10.64 13.61 17.8COP range 8.5-5.11 8.4-5.02 6.2-4.14Average COP at 50% speed 6.5 6.4 4.7Performance – air 35°C 80% RH, Water 28°CCooling capacity kW 6.23 6.7 10.3Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50Rated input power kW 0.20-2.24 0.40-2.38 0.75-4.75Rated input current A 1.21-8.9 1.23-12.0 3.45-19.6Maximum input current A 12.5 15.5 24.5Water flow m3/h 4.97 6.5 8.98Water connection mm2 1½" or 50mm 1½" or 50mm 1½" or 50mmCompressor Inverter Inverter InverterCondenser Titanium Titanium TitaniumR32 gas weight g 800 800 1700Sound level @ 10m dB(A) <29 <30 <30Sound level @ 1m dB(A) <47 <48 <48Product size (w x d x h) mm 650 x 650 x 760 650 x 650 x 760 750 x 750 x 860Net Weight kg 70 80 95
14
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
CO M M E R C I A L
Features
�Designed for the Gulf climate
�Zero ozone depleting R134a refrigerant – ensures reliable, efficient operation regardless of air temperature
�Titanium or CuNi heat exchanger
�Fully automatic operation
�Scroll compressors
�Water flow switch on all models
�Comprehensive circuit protection
�Quiet, efficient owlet axial fans
�Weather-proof construction
�Digital thermostat – choice of in-built positions
Options
�Chiller or heater only
�3ph, 60Hz versions
�Soft start
�High pressure fan
�Condensate insulation kit for plant room installations
Specifications Units PPT 16BHC PPT 22BHC
Air temperature rangeWater temperature range
Heating output @ +20°C/85% RH ambientHeating input @ +20°C/85% RH ambient
Cooling output @ +45°C/50% RH ambientCooling input @ +45°C/50% RH ambient
°C°C
kWkW
kWkW
10-5510-38
11.82.1
9.83.2
10-5510-38
15.02.7
12.44.1
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5010164825
400/3ph/5013204825
Nominal air flowFan external resistance (standard)
m3/hPa
40000
50000
Water flow ±10% (CuNi/Titanium heat exchanger)Pressure drop (water)Water connectionsCondensate water connectionsCompressorFanSound level @ 3m
l/minm hdinch
" BSPMTypeTypedB(A)
n/a/123n/a/0.2
1½ F/PVC½ ABS
1 x Scroll1 x Axial
48
n/a/123n/a/0.2
1½ F/PVC½ ABS
1 x Scroll1 x Axial
52Product size (w x d x h)Weight
mmkg
1264 x 600 x 725131
1264 x 600 x 725145
Applications
�Outdoor and indoor pools (Gulf and SE Asia)
�Health clubs and wellness centres
�Hotels and spa pools
P R O - PAC 16 B H C
Output and input calculated at water temperature 26°C for heating, and 32° for cooling
15
TO
HE
AT
TO
CO
OL
Options
�Chiller or heater only
�3ph, 60Hz versions
�Soft start
�High pressure fan
�Condensate insulation kit for plant room installations
Applications
�Outdoor and indoor pools (Gulf and SE Asia)
�Health clubs and wellness centres
�Hotels and spa pools
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
CO M M E R C I A L
Features
�Zero ozone depleting R134a refrigerant – ensures reliable, efficient operation regardless of air temperature
�Titanium or CuNi heat exchanger
�Fully automatic operation
�Scroll compressors
�Water flow switch on all models
�Comprehensive circuit protection
�Quiet, efficient owlet axial fans
�Weather-proof construction
�Digital thermostat
P R O - PAC 30 B H C
Specifications Units PPT 30BHC PPT 45BHC PPT 70BHC PPT 90BHC PPT 140BHC
Air temperature rangeWater temperature range
Heating output @ +20°C/85% RH ambientHeating input @ +20°C/85% RH ambient
Cooling output @ +45°C/50% RH ambientCooling input @ +45°C/50% RH ambient
°C°C
kWkW
kWkW
10-5510-40
31.05.5
25.58.3
10-5510-40
36.46.7
30.010.0
10-5510-40
61.910.5
51.016.2
10-5510-40
72.713.3
59.920.0
10-5510-40
123.821.0
102.132.4
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5021309633
400/3ph/502540
10234
400/3ph/5042609633
400/3ph/505070
10234
400/3ph/5084
1259633
Nominal air flowFan external resistance (standard)
m3/hPa
55000
110000
140000
220000
280000
Water flow ±10% (CuNi/Titanium heat exchanger)
Pressure drop (water)Water connectionsCondensate water connectionsCompressorFanSound level @ 3m
l/minm hdinch inchTypeTypedB(A)
n/a/250n/a/0.7
n/a/2 union1½ BSPM1 x Scroll1 x Axial
64
66/3004.5/0.4
1½ BSPM/2 union1½ BSPM1 x Scroll1 x Axial
65
133/5003.4/1.5
1½/3 BSPM1½ BSPM2 x Scroll1 x Axial
70
166/6004.5/1.7
1½/3 BSPM1½ BSPM2 x Scroll2 x Axial
65
266/10005.3/2.1
2/4 BSPM1½ BSPM4 x Scroll2 x Axial
70Width DepthHeightWeight
mmmmmmkg
1525790
1080219
166510601310329
181011901310549
206511901330599
2210165013401065
Output and input calculated at water temperature 26°C for heating, and 32° for cooling
16
Features
�Capacities from 32kW to 125kW
�Purpose designed components for pool heating
�Can be installed outside or in a plant room
�High efficiency spiral wound full flow titanium condenser
�Leading brand scroll compressors
�Quiet, efficient owlet axial fans
�Plastisol coated cabinet
�Water flow switch
�Condensate collector
� Standard models operate in air temperatures above +10°C. These models are designed for seasonal use
� Pro-Pac Y models are fitted with reverse cycle defrost and will operate in air temperatures as low as -15°C, therefore they are suitable for all season use and indoor swimming pools
Applications
�Indoor or outdoor pools
�Water parks
�Hotel pools
�Holiday parks and campsites
P R O - PAC 30 B M
Options
�Soft start
�High pressure fan
* Y model only -15 - +40°COutput and input calculated @ 26°C water temperature
Specifications Units PPT 30BM PPT 45BM PPT 70BM PPT 90BM PPT 140BM
Air temperature rangeWater temperature range
Output @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ -3°C/100% RH ambient*Input @ -3°C/100% RH ambient*
Power supplyMinimum supply capacityRecommended supply fuseNominal air flowWater flowPressure dropWater connectionsCompressorCondenserSound level @ 10mSound level @ 3mProduct size (w x d x h)Weight - Standard modelsWeight - Y models
°C°C
kWkW
kWkW
kWkW
V/HzAA
m3/hl/minm hdinchTypeTypedB(A)dB(A)mmkgkg
10-4010-38
36.36.7
29.66.2
17.45.4
400/3ph/502030
55002500.7
2 Union1 x Scroll Titanium
5464
1585 x 790 x 1080219233
10-4010-38
45.28.6
36.98.0
21.76.9
400/3ph/502230
120003000.4
2 Union1 x Scroll Titanium
5565
1695 x 1060 x 1330330337
10-4010-38
68.312.3
55.711.4
32.79.8
400/3ph/503550
140005001.5
3 BSPM1 x Scroll Titanium
5970
1840 x 1190 x 1310417435
10-4010-38
96.318.1
78.516.8
46.114.5
400/3ph/504360
240006001.4
3 BSPM2 x Scroll Titanium
5565
2095 x 1190 x 1350633661
10-4010-38
136.624.7
111.322.8
65.419.6
400/3ph/5067
1002800010002.1
4 BSPM2 x ScrollTitanium
5970
2250 x 1650 x 1340816880
P O O L WAT E R H E AT P U M P S – A I R S O U R C E
CO M M E R C I A L
17
TO
CO
OL
Cold plunge pool water
Cold-water treatments have been used for thousands of years all over the world to maintain physical health. It improves circulation and the immune system, makes for healthy skin and hair and increases energy.
A Calorex water chiller can provide a plunge pool in your home or business with the temperature you need. The chemical resistant cupro-nickel material of the heat exchangers and the use of R134a refrigerant means that these chillers can be connected directly to the pool water circuit and chill the water to10°C. Also, due to the weatherproof construction of the chillers, you have a range of installation options for both plants rooms and outside areas.
When cool is not cold enough
Whether you are a professional footballer, athlete or keen sports person, cold-water immersion is a very popular treatment method for repairing muscles and speeding up recovery from injuries. In certain situations, where 10°C is not cold enough, the water for these treatments is required to be as low as 4°C. Water may also need to be as low as this in some commercial and industrial processes. In these cases, the chillers can be connected in line with a stainless steel plate heat exchanger, and connected to the water. This allows a glycol mix to be used in the chiller to get the temperatures required.
WAT E R C H I L L E R SCalorex water chillers are ideal for plunge pools in spas and water immersion pools for sports recovery.
Plunge pool
Calorex WA 634 water chiller
Circulating pump @ 33 l/min
Water circulating pump
Plunge pool
Insulated shellIsolating valves
Water circulating pumpPlate heat exchanger
Mains fill
Isolating valves
Expansion tank 10L/KW
For correct sizing of the chiller and/or plate heat exchanger for all applications please contact our dedicated sales team who can assist in tailoring the selection for your project.
17
18
Features
�Domestic sizes giving up to 900 litres per hour of cold water production
�Mono-block design with choice of in-built thermostat positions
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134a)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
Applications
�Sports academies
�Sports training facilities
�Plunge pools
�Therapy pools
P R O - PAC 16 B C
P O O L WAT E R CO O L I N G – A I R CO O L E D H E AT P U M P S
D O M E S T I C A N D CO M M E R C I A L
Options
�Available in 60Hz
Specifications Units PPT 16BC PPT 22BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-38
9.83.2
5.92.5
10-5510-38
12.44.1
7.53.3
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5010164825
400/3ph/5013204825
Nominal air flowFan external resistance (standard)
m3/hPa
40000
50000
Water flow ±10%Pressure drop (water)Water connections
l/minm hdinch
334.2
1½ BSPF
334.2
1½ BSPFCompressorFanSound pressure level @ 3mProduct size (w x d x h)Weight
TypeTypedB(A)mmkg
1 x Scroll1 x Axial
481264 x 600 x 725
131
1 x Scroll1 x Axial
521264 x 600 x 725
145Cooling output and input calculated at +45°C/50% RH ambient air
19
TO
CO
OL
Features
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134a)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
Applications
�Sports academies
�Sports training facilities
�Plunge pools
�Therapy pools
P R O - PAC 140 B C
P O O L WAT E R CO O L I N G – A I R CO O L E D H E AT P U M P S
CO M M E R C I A L
Options
�Available in 60Hz
Specifications Units PPT 30BC PPT 45BC PPT 70BC PPT 90BC PPT 140BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-38
25.58.3
15.56.6
10-5510-38
30.0 10.0
18.28.0
10-5510-38
51.0 16.2
30.912.8
10-5510-38
59.920.0
36.316.0
10-5510-38
102.132.4
61.925.5
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5021309633
400/3ph/502540
10234
400/3ph/5042609633
400/3ph/505070
10234
400/3ph/5084
1259633
Nominal air flowFan external resistance (standard)
m3/hPa
55000
110000
140000
220000
280000
Water flow ±10%Pressure drop (water)Water connections
l/minm hdinch
662.1
1½ BSPM
664.5
1½ BSPM
1333.4
1½ BSPM
1664.5
1½ BSPM
2665.3
2 BSPMCompressorFanSound pressure level @ 3mProduct size (w x d x h)Weight
TypeTypedB(A)mmkg
1 x Scroll1 x Axial
621525 x 790 x 1080
219
1 x Scroll1 x Axial
641665 x 1060 x 1310
329
2 x Scroll1 x Axial
681810 x 1190 x 1310
549
2 x Scroll2 x Axial
702065 x 1190 x 1330
599
4 x Scroll2 x Axial
712210 x 1650 x 1340
1065Cooling output and input calculated at +45°C/50% RH ambient air
T H E C H A L L E N G EPool hall air contains moisture which when left unresolved can lead to discomfort, mould or possible structural damage.
Why dehumidify?
An indoor swimming pool is a wonderful leisure and exercise environment but the evaporation from the water surface poses real problems for the building structure. Prolonged exposure to high humidity causes walls, decorative finishes and roofs to deteriorate rapidly.
Personal comfort is also of prime importance. High humidity causes personal discomfort and unless the environment is controlled, bathers will be prevented from enjoying the swimming pool. Bathers appreciate comfortable humidity in the range 55%-65%.
Evaporation
When a pool is uncovered, evaporation is inevitable leading to excess humidity in the air. The problems caused by this excess humidity include discomfort, condensation, misting, damp, mould, mildew, corrosion and building deterioration.
As water evaporates from the pool, it takes a significant amount of heat with it. The traditional approach came in the form of wasteful extraction that removes this energy from the pool hall.
Dehumidifier
A dehumidifier not only removes the humidity but also recovers the energy it contains to help with heating the building. The advanced range of Calorex dehumidifiers provide an efficient and economical solution.
Humid Air Dry, WarmAir
Expansion
Evaporator Condenser
Condensateto waste
20˚C28˚C
80%40%
Compressor
How a Calorex dehumidifier works
The process of dehumidification involves moisture-laden air being drawn into a dehumidifier where the air passes across a refrigerated coil. The air is rapidly cooled below its dew point, condensing the water vapour and recovering its latent heat energy for re-use. The cooled air is then passed across the condenser where it is reheated and returned to the served area at the required lower relative humidity.
20
Our products
High-performance low-cost Calorex dehumidifiers minimise the need for costly air extraction. Operating on the heat pump principle, these high-performance units recirculate pool air – removing the moisture content and delivering warm, dry air back to the pool hall. By working in this way, they maintain a comfortable humidity, reduce condensation and keep heating costs at the lowest possible level.
Rapid installation, flexible operation
Fully self-contained units, Calorex dehumidifiers require minimal installation. When it comes to operation, units offer quiet, reliable and safe performance. Flexibility is built-in. DH 33 and DH 55 models come with a specially styled barrel type discharge that allows air to be directed in an 80° range between horizontal and vertical, thus allowing installation at high or low level.
Energy saving
Removing humidity from the air enables the Calorex dehumidifier to absorb latent energy and return it to the pool air as useful air heating. Its heat pump technology converts 2.5kW to air heating for every 1kW of electricity consumed – a real bonus for running costs!
So that the best choice can be made, a full range of units is available. Each is supplied with full installation kit, and sound insulation. The Calorex dehumidifier range includes wall mounted and floor standing units.
Low temperature operation
Your pool hall still needs protection when you aren’t using it, but economy dictates that you drop the air heating levels when you are away. The standard defrost function allows operation down to temperatures just above freezing to ensure moisture control even in cold conditions.
T H E S O LU T I O NThe Calorex range of purpose built, stylish dehumidifiers for humidity control and energy recovery in indoor swimming pools.
Benefits
�Energy efficient
�Low temperature operation
�Available with air heating option
�Automatic operation
�Quality construction
�Optional features
�Simple installation
�Heat recovery to air21
Calorex dehumidifiers maintain a comfortable humidity, minimise condensation and keep heating costs at the lowest possible level.
22
P O O L D E H U M I D I F I E R S
WA L L M O U N T E D
Features
�High moisture extraction for low power consumption
�Zero ozone depleting refrigerant
�Low internal operating pressures = long useful life
�Fan cycle or continuous mode
�Air outlet adjustable to horizontal or vertical
�Hot gas defrost (allows operation to 5°C air temperature)
�Many options for flexible installation
�Remote humidistat and on/off function
Applications
� Indoor pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
� Holiday parks and campsites
Specifications Units DH 33
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-351.251.9440
048
R407c230/1ph/50
0.754.41015
Optional LPHW35
780 x 255 x 6533716
D H 33
Options
�Through the wall version
�LPHW air heater
�Air filter
�Floor stand kit
Performance data
4.03.63.22.82.21.61.20.80.40.0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C
Defrost Zone
2.01.81.61.41.21.00.80.60.40.20.0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C
40%RH 50%RH 60%RH 70%RH 80%RH
Defrost Zone
40%RH 50%RH 60%RH 70%RH 80%RH
23
TO
DR
Y
P O O L D E H U M I D I F I E R S
WA L L M O U N T E D
Features
�High moisture extraction for low power consumption
�Zero ozone depleting refrigerant
�Low internal operating pressures = long useful life
�Fan cycle or continuous mode
�Air outlet adjustable to horizontal or vertical
�Hot gas defrost (allows operation to 5°C air temperature)
�Many options for flexible installation
�Remote humidistat and on/off function
Applications
� Indoor pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
� Holiday parks and campsites
Specifications Units DH 55
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-352.53.5740
048
R407c230/1ph/50
1.27.51330
Optional LPHW55
1245 x 255 x 6535816
D H 55
Options
�Through the wall version
�LPHW air heater
�Air filter
�Floor stand kit
Performance data
4.03.63.22.82.21.61.20.80.40.0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C
Defrost Zone
2.01.81.61.41.21.00.80.60.40.20.0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C
40%RH 50%RH 60%RH 70%RH 80%RH
Defrost Zone
40%RH 50%RH 60%RH 70%RH 80%RH
24
P O O L D E H U M I D I F I E R S
F LO O R S TA N D I N G
7
6
5
4
3
2
1
0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C 40˚C
40%RH 50%RH 60%RH 70%RH 80%RH
40%RH 50%RH 60%RH 70%RH 80%RH
Defrost Zone
7
6
5
4
3
2
1
0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C 40˚C
Defrost Zone
Performance data
DH 75 DH 110
7
6
5
4
3
2
1
0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C 40˚C
40%RH 50%RH 60%RH 70%RH 80%RH
40%RH 50%RH 60%RH 70%RH 80%RH
Defrost Zone
7
6
5
4
3
2
1
0
Litre
s/hr
5˚C 10˚C 15˚C 20˚C 25˚C 30˚C 35˚C 40˚C
Defrost Zone
D H 110Features
�High moisture extraction for low power consumption
�Corrosion free, easy to clean aluminium air grille with easy clean air filter
�Zero ozone depleting refrigerant
�Low internal operating pressures = long useful life
�Adjustable air outlet
�Quiet centrifugal fans, two speeds
�Hot gas defrost (allows operation to 5°C air temperature)
�Remote humidistat and on/off function
Applications
�Indoor pools
�Therapy pools
�Health clubs and wellness centres
�Hotels and spa pools
�Holiday parks and campsites
Options
�Through the wall version
�LPHW air heater complete with 3 way valve and 12V thermostat interlock
�400V-3ph option for DH 110
25
TO
DR
Y
P O O L D E H U M I D I F I E R S
A I R F LO W – H O W I T W O R K S
Warm Dry Air
Warm Wet Air
Calorex
Ground LevelBoiler
BoilerGround Level
Warm Wet Air
Condensate Water to Waste
Warm Dry Air
Calorex
Boiler
Warm Wet AirCondensateWater to Waste
Warm Dry Air
Calorex
Ground Level
Ground Level Pool WaterApprox 26˚C
Warm Wet Air
Hall Air Temperature Approx 28˚C
Condensate Water to Waste
Warm Dry Air
Calorex
Warm Dry Air
Ground Level Pool WaterApprox 26˚C
Warm Wet AirCalorex
Ground LevelPool WaterApprox 26˚C
Pool WaterApprox 26˚C
Pool WaterApprox 26˚C
Pool WaterApprox 26˚C
Warm Wet Air
Hall Air Temperature Approx 28˚C
CondensateWater to Waste
Warm Dry Air
Calorex
Wall mounted air �ow
Wall mounted with air heating
Through the wall
Floor standing air �ow
Floor standing with air heating
Through the wall with air heating
Each Calorex unit includes an adjustable humidistat controlling relative humidity (RH) in the ideal range of 55% – 65%. With RH under control, condensation can be minimised by selecting the most appropriate installation from the schematics shown below. Note: vulnerable areas such as windows, roof lights or other cold bridges may form condensation at low external air temperatures unless dry air is blown directly onto them.
Specifications Units DH 75AX DH 110AX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (brass compression)
°Cl/hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-353.64.0
11800
53R407c
230/1ph/501.59.51355
Optional LPHW8.99.6
1520 x 385 x 79614315
5-354.55.2
11800
53R407c
230/1ph/502.1122066
Optional LPHW8.99.6
1520 x 385 x 79614415
T H E C H A L L E N G EProviding co-ordinated environmental control, moisture removal and fresh air provision without wasting energy or compromising operating conditions.
Why control the environment?
There are many important factors to consider when planning and designing an indoor swimming pool. These include optimising the internal environment to provide a comfortable, safe and enjoyable experience for swimmers, safeguarding the building structure from dangerous condensation and humidity related degradation. At the same time, minimising running costs and energy use are critical for commercial and environmental reasons.
Evaporation
Maintaining a comfortable pool environment requires the pool water and air to be heated and held at approximately 28°C and 30°C respectively. Commercial and leisure pools are uncovered for long periods so high rates of evaporation are inevitable leading to excess humidity in the air.
As water evaporates from the pool, it takes a significant amount of heat with it. As a result of this continuous evaporation, uncomfortable humid air containing vast amounts of valuable heat
in the form of latent energy must be removed from the pool hall. The traditional approach came in the form of wasteful extraction that removes this energy from the pool hall, and heat exchangers fed by fossil fuel boilers to continuously replace heat lost from the pool and to heat the fresh air used to replace the extracted warm humid air.
Heat pump heat recovery
In contrast to most indoor environments, swimming pool buildings contain substantially more energy in the air, so a conventional air handling unit is not designed to handle this challenge.
Calorex AHUs, with heat pump dehumidification, not only remove the excess humidity but also recover the energy it contains to recycle it back to the pool water and reheat the air. This creates a continuous heat cycle, which is typically sufficient to provide for all the evaporation heat losses from the pool, removing most of the need to supply new heat to the water. The potential energy savings are huge, helping to keep running costs to a minimum.
26
Our products
Calorex are a leading manufacturer of swimming pool environmental control systems that provide dehumidification, heat recovery and ventilation solutions based around heat pump technology.
A swimming pool environmental control unit must carry out its primary task of dehumidifying the pool hall air, be designed and constructed to withstand aggressive pool air, and provide a variable quantity of fresh air for occupants.
Calorex AHUs will provide the complete answer to humidity control, water/air temperature control and dynamic fresh air requirements.
By recovering the latent energy in the moisture laden air of a pool hall, a Calorex AHU will return this energy to heat the pool water or use it to assist with the air heating.
Furthermore, there is usually sufficient recovered energy to provide all the evaporation water heating requirements with the surplus used for air heating.
Energy efficiency and CO2 savings
Local authorities and leisure operators find themselves under more pressure than ever to demonstrate effective energy efficiency.
Typically for every unit of power that a Calorex heat pump AHU consumes, it will convert up to three times this amount into usable heat. Compared to traditional extract and ventilation solutions, cost savings of over 50% are achievable while associated CO2 emissions may be reduced by up to 70%.
T H E S O LU T I O NThe Calorex range of purpose built, sophisticated air handling units incorporating heat pump and fresh air dehumidification technology.
Benefits
�Dehumidification and ventilation systems with dynamic heat pump heat recovery to air and water
�Purpose built to withstand aggressive swimming pool atmospheres
�Automatic operation
�Energy efficient with running costs reduced by up to 70%
�Carbon emissions reduced by up to 70%27
Calorex air handling units take care of heating, humidity control, ventilation and energy recovery in an efficient and economical way.
28
Features
All models:
� Pool hall dehumidification
� Dynamic heat pump heat recovery
� Constant flow fan with two speed settings
� Remote control panel (12V) with 1.8m lead (10m cable optional)
LPHW Air models add:
� Integral LPHW heat exchanger for air heating
LPHW Air+Water models add:
� Integral LPHW heat exchangers for pool and air
A A 300A A 500
Applications
� Indoor pools
� Private pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
Specifications Units AA 300 AA 500
Air flowExternal available static pressureDehumidification @ 30°C/60% RH
m³/hPal/h
1300 ± 10% 2503.6
1800 ± 10% 2504.5
Heat to airVia heat pump kW 4.4 6.1Via LPHW (LPHW Air models) kW 7.3 7.5Total (heat pump + LPHW) kW 9.8 11.7Heat to waterVia LPHW (LPHW Air + Water models) kW 9.5 9.5Product size (h x w x d) mm 850 x 1027 x 730 850 x 1027 x 730Weight kg 111 111
Options
� Flexible flange kit to reduce vibration
F L A N G E K I T
Ducted heat pump dehumidification
P O O L A I R H A N D L I N G U N I T S
A A 300/500
29
TO
DR
Y
Features
� Pool hall dehumidification
� Dynamic heat pump heat recovery to pool and air
� Constant flow EC fan (models 600, 900, 1200)
� Speed controllable EC fan (model 1500)
� PLC control with 3.5" touchscreen user interface
� Remote monitoring/control
AA+LPHW models add:
� Integral LPHW heat exchanger for air heating
AW models add:
� Dynamic heat pump heat recovery to pool and air
� Integral LPHW heat exchangers for pool and air
Applications
�Spa and therapy pools
�Hotel pools and wellness centres
�Holiday parks & campsites
AW 1200
Options
� Fresh air module
� Upgraded LPHW heat exchanger for air
� Electric resistance air heaters (6/12/18kW)
� Air cooling with remote condenser
� Titanium pool condenser (AW models only)
Electrical heater option notes
� In lieu of LPHW heat exchangers
� 6kW or 12kW is available for 600 and 900 models
� 12kW or 18kW is available for 1200 and 1500 models
VA R I H E AT TO U C H S C R E E N
Ducted heat pump dehumidification with heat recovery
P O O L A I R H A N D L I N G U N I T S
VA R I H E AT S YS T E M S
30
Installation options
Top outlet
Basement outlet Remote condensing unit option
Bottom outlet
Horizontal outlet Top outlet Bottom outlet
P O O L A I R H A N D L I N G U N I T S
VA R I H E AT S YS T E M S
31
TO
DR
Y
Specifications Units AW 600 AA 600 AW 900 AA 900 AW 1200 AA 1200 AW 1500 AA 1500
Air flowExternal available static pressureFresh air flow (option)External available static pressureDehumidifcation @ 30oC/60% RHDehumidifcation @ 30oC/70% RH
m3/hPa
m3/hPal/hl/h
2000330
0-9001004.65.5
2000330
0-9001004.65.5
2500220
0-9001006.57.8
2500220
0-9001006.57.8
3500290
0-9001008.5
10.8
3500290
0-9001008.5
10.8
4300350
0-90010010.513.2
4300350
0-90010010.113.2
Heat to airNet via heat pump (Mode B)Via standard LPHW @ 80oCMax. available (Mode B + standard LPHW)Via upgraded LPHW @ 55oCMax. available (Mode B + upgraded LPHW)
kWkWkWkWkW
5.111.014.09.4
12.7
5.111.014.09.4
12.7
7.113.518.611.516.9
7.113.518.611.516.9
10.024.030.020.427.0
10.024.030.020.427.0
14.028.036.023.836.8
14.028.036.023.836.8
Heat to waterNet via heat pump (Mode A)Via LPHW @ 80oCMax. available (Mode A + LPHW)
kWkWkW
5.518.023.5
000
7.430.037.4
000
10.030.040.0
000
12.540.052.5
000
Nominal power consumed kW 2.1 2.1 2.8 2.8 3.6 3.6 4.7 4.7
AW denotes heat recovery to air/water and LPHW heaters for air/water AA denotes heat recovery to air and optional LPHW heater for air only
Variheat 600/900fig 1 fig 2 fig 3 fig 4
H 1574 1574 977 1028L 842 1180 1574 1929D 839 839 700 700
fig 1 fig 2 fig 3 fig 4H 1778 1778 1110 1130L 942 1295 1778 2133D 955 955 800 800
Configurations
Variheat 1200/1500
fig 1 fig 2 fig 3 fig 4
H
L L L L
H H H
fig 1 fig 2 fig 3 fig 4
H
L L L L
H H H
Example configurations are shown but alternative configurations are available.
P O O L A I R H A N D L I N G U N I T S
VA R I H E AT S YS T E M S
32
Features
�Dynamic heat pump heat recovery to pool and air
�Self-regulating fresh air control with heat recovery
�Automatic control of exhaust air volume to match pool usage
�Free-cooling (Delta 1-2)
�Free-cooling and heat pump air cooling (Delta 4-16)
�Integral LPHW heat exchangers for pool and air
�Speed controllable EC/inverter fans in all models
�PLC control with 5.7" touchscreen user interface
�Remote monitoring/control
Remote monitoring/control
As standard the following remote connectivity is available:
�Screen mirroring to Android/iOS mobile devices using third-party app
�Screen mirroring to web browser with ActiveX
�BMS interfaces for Modbus, BACnet IP and BACnet MS/TP
�Wired remote control interfaces
D E LTA 4
D E LTA TO U C H S C R E E N
Applications
�Health clubs and wellness centres
�Holiday parks and campsites
�Hotel and spa pools
�Leisure centres
�Water parks
Ducted heat pump dehumidification, ventilation and heat recoveryDucted heat pump dehumidification, ventilation and heat recovery
P O O L A I R H A N D L I N G U N I T S
D E LTA S YS T E M S
33
TO
VE
NT
ILA
TE
Delta operating on maximum dehumidification of pool air with full heat recovery to pool water and air. Available energy is removed from exhaust air stream. Supplementary heat, if required, supplied by LPHW (water or air).
CONDENSATE
Retu
rn A
ir
Supp
ly A
ir
WARM DRY AIR
Full dehumidification and heat recovery
HOT DRY AIR COOL DRY AIR WARM HUMID AIR
How the air flows through the Delta
Delta operating on light dehumidification with full heat recovery and reduced fresh air stream – control system automatically selects correct operating mode and damper position. LPHW heat available when required.
CONDENSATE
Retu
rn A
ir
Supp
ly A
ir
WARM DRY AIR
Light dehumidification and heat recovery
HOT DRY AIR COOL DRY AIR WARM HUMID AIR
Delta models 4 and above provide an air conditioning facility to minimise the effects of solar gain from larger glazed areas or very high usage. Automatic damper and mode control.
Supp
y A
ir
Retu
rn A
ir
CONDENSATE
WARM DRY AIR
Air-conditioning
HOT DRY AIR COOL DRY AIR WARM HUMID AIR
Air temperature set back control is incorporated as standard in all Delta units and controlled by a time clock. Pool hall air is dropped to a lower temperature for maximum economy. Air recirculation is maintained, dampers allow low fresh air flow.
CONDENSATE
Retu
rn A
ir
Supp
y A
ir
WARM DRY AIR
Night set back
HOT DRY AIR COOL DRY AIR WARM HUMID AIR
P O O L A I R H A N D L I N G U N I T S
D E LTA S YS T E M S
34
Specifications Units DT 1 DT 2 DT 4 DT 6 DT 8 DT 10 DT 12 DT 14 DT 16
Nominal recirculation air flow m3/h 2500 2600 3000 4000 5000 6000 7000 10000 12000Exhaust/fresh air flow (stepped control) m3/h 120-1200 130-1300 150-1500 200-2000 250-2500 300-3000 350-3500 670-6700 850-8000Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air l/h 9.8 10.9 12.5 16.6 20.8 25.0 29.2 56.5 62.4Heat to airVia heat pump (Mode B)Via standard LPHW @ 80°CVia upgraded LPHW @ 55°CTotal Mode B + standard LPHW
kWkWkWkW
3.82017
23.8
4.92219
26.9
5.12521
30.1
6.63026
36.6
8.03530
43.0
10.03832
48.0
12.14236
54.1
30.08572
115.0
35.09077
125.0Heat to pool waterVia heat pump (Mode A)Via LPHW @ 80°CVia LPHW @ 55°CTotal Mode A + LPHW
kWkWkWkW
4.02311
27.0
5.52311
28.5
5.83316
38.8
8.03316
41.0
10.03316
43.0
12.54020
52.5
15.04020
55.0
35.06532
100.0
43.06532
108.0Cooling dutyTotalSensible
kWkW
00
00
-4.2-2.9
-5.5-3.9
-6.7-4.7
-8.4-5.9
-10.1-7.1
-23.0-13.0
-28.0-15.0
Nominal power consumed kW 2.6 2.9 2.9 3.4 4.4 5.9 7.4 12.3 17.0WidthDepthHeightWeight
mmmmmmkg
1740654
1685300
1740654
1685310
1840704
1970350
1840704
1970360
1840704
1970370
1840854
1970410
1840854
1970460
286011262120954
2860112621201020
Options
�Delta 1-6 single or three phase
�Delta 8-16 three phase only
�Upgraded LPHW heat exchanger for air heating
�Left-hand or right-hand orientation (Delta 4-16)
�Top, side or bottom supply fan outlet
�Front or rear supply fan outlet (Delta 14-16)
�Rear exhaust and fresh air connections (Delta 14-16)
P O O L A I R H A N D L I N G U N I T S
D E LTA S YS T E M S
35
TO
VE
NT
ILA
TE
Applications
�Leisure centres
�Olympic pools
�Hotel pools
�Wellness centres
�Health clubs
�Holiday parks & campsites
Features
�Dynamic heat pump heat recovery to pool and air
�Self-regulating fresh air control
�Automatic control of exhaust air volume to match pool usage
�Free-cooling (HRD 15-20)
�Free-cooling and heat pump air cooling (HRD 25-30)
�Integral LPHW heat exchanger for air heating
�Double skinned insulated cabinet
�Bespoke fan specifications
Options
�Upgraded LPHW heat exchanger for air heating
�Left-hand or right-hand orientation
�Choice of supply fan outlet orientations
�Choice of fan static pressures
�BMS interface
H R D 30
Specifications Units HRD 15 HRD 20 HRD 25 HRD 30
Nominal recirculation air flowExhaust/fresh air flow (stepped control)Dehumidification @ 28°C/60% RH by heat pumpTotal by heat pump and maximum fresh air
m³/hm³/h
l/hl/h
120006000
3163
1950013500
45116
2500018000
68152
3500023000
88210
Heat to airVia heat pump (Mode B)Via standard LPHW @ 80°CMaximum available (Mode B + standard LPHW)Heat to waterVia heat pump (Mode A)
kWkWkW
kW
3770
107
40
55100155
60
72150222
95
90210300
117Cooling dutySensible Mode ASensible Mode B
kWkW
-20 -30
-49-30
-67-37
Nominal power consumed (dependent upon main fan duty) kW 17 23 31 44
P O O L A I R H A N D L I N G U N I T S
H R D S YS T E M S
36
W H Y A C A LO R E X H E AT P U M P ?Calorex heat pumps provide a sustainable heating solution which, compared to fossil fuel or direct electric systems, will dramatically cut operating costs and carbon emission.
Calorex air source heat pumps can use source heat from every climatic condition and are available in different designs to suit space or hot water heating.
Calorex products offer industry leading standards of efficiency and durability and are supported by comprehensive technical support that guarantees correct product specification and after sales care.
Unrivalled efficiency
Unlike fossil fuel and direct electric heating systems, a Calorex heat pump is capable of delivering up to five times more energy than it consumes, and unlike solar systems, Calorex heat pumps do not need the sun to shine in order to provide this efficiency.
COOL GASHOT GAS
HEATEXCHANGER
EVAPORATOR
COLD LIQUIDREFRIGERANT
HIGH PRESSURE SIDE
CONDENSEDREFRIGERANT
COMPRESSOR
EXPANSIONVALVE
AMBIENTAIR
LOW PRESSURE SIDE
WATER OUT
WATER IN
THE HEAT PUMP CYCLE
The heat pump cycle
Heat pump efficiency at differing air temperatures
Free heat from the air
Energy consumed
Total heat recovered
C.O.P. 5 : 1 4 : 14.5 : 1 3.5 : 1 2.5 : 1
2 paid for units 2 paid for units 2 paid for units 2 paid for units 2 paid for units
10 units recovered 9 units recovered 8 units recovered 7 units recovered 5 units recovered
8 free units
7 free units6 free units
5 free units 3 free units
Total heat recovered ÷ energy consumed = Coe�cient of Performance (C.O.P.)
25° 20° 15° 10° 0°
37
TO
HE
AT
E A S Y I N S TA L L AT I O NThe Calorex range of hot water heat pumps are a quality range of packaged units specifically designed for hot water heating to 68°C.
Calorex heat pumps are simple to install, require little maintenance and alleviate the need for fuel storage tanks and flues that are normally associated with fossil fuel heating systems. Further, due to their unique ability to collect and enhance "free" heat from the air around them, they are kinder to the environment than traditional heating systems and exceptionally inexpensive to operate.
Calorex Pro-Pac range
Pro-Pac heat pumps can be installed outside or in a plant room that has adjacent outside walls. Pro-Pac can be supplied with high speed axial fans.
Typical installation diagram for Calorex hot water heat pump
WRAS approved
WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
37
Harness the heat you don’t have to pay for with Calorex’s range of air source heat pumps.
38
WAT E R H E AT I N G – A I R S O U R C E H E AT P U M P S
D O M E S T I C
Features
�Efficiencies of up to 500% – most of the energy that is provided is absorbed completely free of charge from ambient air around the heat pump
�Monobloc construction with choice of inbuilt thermostat positions. Alternatively, the unit can be controlled by a remote water tank thermostat
�High efficiency, sound insulated scroll compressor.
�Quiet, efficient owlet axial fan
�Plastic coated, galvanised case
�Certified cupronickel WRAS approved heat exchanger to allow the unit to be used in a direct system with potable water
Options
�R134a refrigerant – allows the unit to operate up to 65°C water temperature
� Soft start
� RS 485 compatible thermostat
Applications
� Hotels
� Hospitals
� Schools
� Swimming pools
� Apartment buildings
� Nursing homes
� Large private houses
P R O - PAC 16 A M Y
Specifications Units PP 16AMY
Air temperature rangeWater temperature range
Output – water 30°COutput @ 15°C ambientOutput @ 7°C ambientOutput @ 0°C ambientInput @ 15°C ambient
°C°C
kWkWkWkW
-15 - +3510-55
11.99.57.93.0
Power supplyMinimum supply capacityRecommended supply fuse
V/Hz(A) 1ph(A) 1ph
230/1ph/5019.830
Air flow m3/h 3500Flow ratePressure dropWater connections
l/minm hdinch
335.0
¾ BSPMCompressorCondenserSound level @ 10mSound level @ 3mProduct size (w x d x h)Weight
TypeTypedB(A)dB(A)mmkg
1 x ScrollWRAS Cu-Ni
4148
1237 x 535 x 725136
39
TO
HE
AT
WAT E R H E AT I N G – A I R S O U R C E H E AT P U M P S
CO M M E R C I A L
P R O - PAC 140 H
Features
�Hot water production to 68°C
�Space heating through fan coils, radiators, underfloor system
�Heat recovery from soil, rivers, lakes and chilled water systems
�Space cooling as a by product of the heating process
�Up to 400% running cost and carbon savings against electric heating
�Up to 48% running cost and carbon savings against fossil fuel system
�No flues or storage tanks
�Easy to retrofit
�Minimal service requirements
�Certified cupronickel WRAS approved heat exchanger to allow the unit to be used in a direct system with potable water
�Range of capacities from 6kW to 140kW
�R134a ozone friendly refrigerant ensures reliable operation up to 68 oC
�Fully weatherproof polyester or epoxy coated cabinet
�Quiet, efficient owlet axial fans
�Choice of centrifugal fans (34 range only) – allows ducting from plant rooms or distribution of cold air for space cooling
�Air source heat pumps for hot water up to 68°C during ambient temperature from 10°C to 50°C (-15°C to 50°C optional)
Applications
� Hotels
� Hospitals
� Clubs
� Leisure centres
AW 1234 H
For technical data see overleaf.
Options
�Reverse cycle defrost allows operation down to -15oC (excluding 834,1234 and 1534)
�Soft start
�High pressure fans
40
WAT E R H E AT I N G – A I R S O U R C E H E AT P U M P S
CO M M E R C I A L
Specifications Units AW 834H AW 1234H AW 1534H
Air temperature rangeWater temperature range
Duty – output to water @ 30°C/55°COutput @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ +5°C/100% RH ambientInput @ +5°C/100% RH ambient
°C°C
kWkW
kWkW
kWkW
7-5010-68
7.5/7.11.5/2.3
6.7/6.01.4/2.1
5.8/5.21.3/2.0
7-5010-68
11.9/10.62.1/3.3
10.1/9.02.0/3.1
8.8/7.91.9/2.9
7-5010-68
15.1/13.52.7/4.3
12.8/11.42.6/4.0
11.2/10.92.4/3.8
Power supply
Minimum supply capacity
Recommended supply fuse
V/HzV/Hz
A (1ph)A (3ph)A (1ph)A (3ph)
230/1ph/50400/3ph/50
15.77.82513
230/1ph/50400/3ph/50
22.712.53220
-400/3ph/50
-13.7
-20
Nominal air flowExternal static (standard units)External static (uprated units)
m3/hPaPa
26500
150
32000
150
40000
Variable to 250Pa
Water flow ±10%Pressure drop (water)Water connections
l/minm hdinch
335.8
¾ BSPM
337.0
¾ BSPM
338.3
¾ BSPMFanCompressorCondenserSound pressure level @ 10mSound pressure level @ 3mProduct size (w x d x h)Weight
TypeTypeTypedB(A)dB(A)mmkg
1 x Centrifugal1 x Recip
4557
1060 x 705 x 807119
1 x Centrifugal1 x Scroll
4859
1060 x 705 x 807130
1 x Centrifugal1 x Scroll
5162
1210 x 755 x 807156
Specifications Units PP 30H PP 45H PP 70H PP 90H PP 140H
Air temperature rangeWater temperature range
Duty – output to water @ 30°C/55°COutput @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ +5°C/100% RH ambientInput @ +5°C/100% RH ambient
°C°C
kWkW
kWkW
kWkW
7-5010-68
25.0/22.34.5/7.1
21.1/18.94.3/6.6
18.4/16.54.1/6.3
7-5010-68
31.2/27.85.9/9.1
26.3/23.65.6/8.5
23.0/20.65.3/8.1
7-5010-68
47.0/41.98.2/13.1
39.8/35.67.8/12.2
34.7/31.07.4/11.6
7-5010-68
62.3/55.511.7/18.2
52.7/47.111.1/17.0
46.0/41.110.6/16.1
7-5010-68
94.0/83.816.5/26.2
79.5/71.115.6/24.4
69.4/62.114.8/23.1
Power supplyMinimum supply capacityRecommended supply fuse
V/HzAA
400/3ph/502030
400/3ph/502230
400/3ph/503550
400/3ph/504460
400/3ph/5070
100Nominal air flowExternal static (standard units)External static (uprated units)
m3/hPaPa
55000
N/A
100000
60
140000
60
200000
60
280000
100Water flow ±10%Pressure drop (water)Water connections
l/minm hdinch
662.1
1½ BSPM
664.2
1½ BSPM
1303.9
1½ BSPM
1304.2
1½ BSPM
2605.3
1½ BSPMFanCompressorCondenserSound pressure level @ 10mSound pressure level @ 3mProduct size (w x d x h)Weight
TypeTypeTypedB(A)dB(A)mmkg
1 x Axial1 x Scroll
5464
1555 x 790 x 1080247
1 x Axial1 x Scroll
5565
1665 x 1060 x 1330329
1 x Axial1 x Scroll
5970
1810 x 1190 x 1310490
1 x Axial2 x Scroll
5565
2065 x 1190 x 1350632
1 x Axial2 x Scroll
5970
2210 x 1650 x 1340858
Cu tube in shell (WRAS approved Cu-Ni optional)
Cu tube in shell (WRAS approved Cu-Ni optional)
41
TO
HE
AT
WAT E R H E AT I N G – WAT E R S O U R C E H E AT P U M P S
CO M M E R C I A L
Features
�Hot water production to 68°C
� Space heating through fan coils, radiators, underfloor system
� Heat recovery from soil, rivers, lakes and chilled water systems
� Space cooling as a by product of the heating process
� Range of capacities from 20kW to 120kW
� R134a refrigerant – wide operating range
� Certified cupronickel WRAS approved heat exchanger to allow the unit to be used in a direct system with potable water
� High efficiency scroll compressors
� Acoustically lined cabinets
� High electrical and mechanical circuit protection
Applications
� Hotels
� Hospitals
� Schools
� Swimming pools
� Apartment buildings
� Nursing homes
� Large private houses
W W 604 B H
Specifications Units WW 304BH WW 604BH WW 1004BH WW 1254BH
Water temperature range HeatingSource water/brine @ 10°COutput to water @ 55°CElectrical inputOutput to water @ 35°CElectrical inputSource water/brine @ 15°COutput to water @ 55°CElectrical inputOutput to water @ 35°CElectrical inputCoolingSource water/brine @ 12°COutput to water @ 55°C sinkElectrical inputOutput to water @ 35°C sinkElectrical input
°C
kWkWkWkW
kWkWkWkW
kWkWkWkW
10-68
26.07.7
29.05.1
31.07.7
34.55.2
18.08.5
25.05.6
10-68
52.015.459.010.2
62.015.567.010.4
36.017.050.011.2
10-68
84.023.792.016.1
100.024.0
109.016.2
60.026.481.017.7
10-68
104.030.8
118.020.4
124.031.0
134.020.8
72.034.0
100.022.4
Power supplyMax. starting current (LRA)Min. supply capacityMax. supply fuseCompressor
V/HzAAA
Type
400/3ph/50102.023.632.0
1 x Scroll
400/3ph/50102.047.363.0
2 x Scroll
400/3ph/5096.079.2
125.04 x Scroll
400/3ph/50102.094.6
125.04 x Scroll
Source flow rate (±10%)Process flow rate (±10%)Water pressure drop (at rated flow)Process water temperature (max.)Water connections (Copper/PVC)
l/minl/minm hd
°Cinch
66.066.04.6
68.01½ BSPM
132.0132.0
4.668.0
1½ BSPM
264.0264.0
5.368.0
2 BSPM
330.0330.0
7.168.0
2½/2 BSPMSound level @ 1mRefrigerantProduct size (w x d x h)Weight
dB(A)
mmkg
68R134a
1665 x 1060 x 1310312
71R134a
1500 x 1500 x 1255625
75R134a
2250 x 1650 x 1215977
75R134a
2250 x 1650 x 12151100
42
Cool domestic water
Calorex water chillers are equipped with cupronickel WRAS approved heat exchangers. This means that you can connect this chiller directly in line with the potable water giving you a more efficient and much simpler installation.
Installation to cool domestic water
Installation when existing storage tank is inadequately insulated or greater than 500 litre capacity
WRAS approved
WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
To domestic cold water services
Circulating pump @ 33 l/min
Calorex WA 634 water chiller
Existing cold water storage tank (insulated), up to 500L capacity
Existing cold water storage tank
Fill
Circulating pump @ 33 l/min
Buffer tank (direct type) normal capacity 125-250 L
Calorex WA 634 water chiller
To prevent the deadly growth of legionella bacteria, algae and contamination of mosquitoes in water storage tanks.
CO L D WAT E R S TO R AG E
42
43
TO
CO
OL
Calorex water chillers are ideal for cooling water for cold-water showers, water immersion pools, therapy pools and water process cooling.
CO L D P LU N G E P O O L WAT E RCold-water treatments have been used for thousands of years all over the world to maintain physical health. It improves circulation and the immune system, makes for healthy skin and hair and increases energy.
A Calorex water chiller can provide a plunge pool in your home or business with the temperature you need. The chemical resistant cupro-nickel material of the heat exchangers and the use of R134a refrigerant means that these chillers can be connected directly to the pool water circuit and chill the water to10°C. Also, due to the weatherproof construction of the chillers, you have a range of installation options for both plants rooms and outside areas.
Indirect chiller system
When cool is not cold enough
Whether you are a professional footballer, athlete or keen sports person, cold-water immersion is a very popular treatment method for repairing muscles and speeding up recovery from injuries. In certain situations, where 10°C is not cold enough, the water for these treatments is required to be as low as 4°C.
Water may also need to be as low as this in some commercial and industrial processes. In these cases, the chillers can be connected in line with a stainless steel plate heat exchanger, and connected to the water. This allows a glycol mix to be used in the chiller to get the temperatures required.
Water circulating pump
Plunge pool
Insulated shellIsolating valves
Water circulating pumpPlate heat exchanger
Mains fill
Isolating valves
Expansion tank 10L/KW
43
44
WAT E R CO O L I N G – A I R CO O L E D H E AT P U M P S
CO M M E R C I A L
Features
�Domestic sizes giving up to 900 litres per hour of cold water production
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS approved heat exchanger to allow the unit to be used in a direct system with potable water
�Non ozone depleting refrigerant (R134a)
WA 1234 B C
Applications
�Water tanks
�Buildings & commercial spaces
�Hotels and clubs
�Offices
�Agriculture
Options
�Available in 60Hz
Specifications Units WA 634ACL WA 634ACH WA 1234BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
0-5510-40
5.51.9
2.81.4
10-5510-40
5.51.9
2.81.4
10-5510-40
9.83.2
5.92.5
Nominal cold water productionMin./max. tank size
l/hl
50060/500
50060/500
900110/1000
Electrical inputPower supplyMax. supply fuseStarting current
kWV/Hz
AA
1.9220-240/1ph/50
2032
1.9220-240/1ph/50
2032
3.2400/3ph/50
1648
Water flow ±10%Flow resistanceConnections
l/minmhdinch
332.1
¾ BSPM
332.1
¾ BSPM
332.1
¾ BSPMNominal air flowFan external resistance (standard)
m³/hPa
150050
150050
300050
FanSound pressure level @ 3mProduct size (w x d x h)Weight
TypedB(A)mmkg
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal65
1060 x 705 x 807157
Cooling output and input calculated at +45°C/50% RH ambient air
45
TO
CO
OL
Features
�Mono-block design with choice of in-built thermostat positions
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS approved heat exchanger to allow the unit to be used in a direct system with potable water
�Non ozone depleting refrigerant (R134a)
Applications
�Water tanks
�Buildings & commercial spaces
�Sports academies
�Sports training facilities
�Plunge pools
�Therapy pools
P R O - PAC 140
Specifications Units PP 16BC PP 22BC PP 30BC PP 45BC PP 70BC PP 90BC PP 140BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-38
9.83.2
5.92.5
10-5510-38
12.44.1
7.53.3
10-5510-38
25.58.3
15.56.6
10-5510-38
30.010.0
18.28.0
10-5510-38
51.016.2
30.912.8
10-5510-38
59.920.0
36.616.0
10-5510-38
102.132.4
61.925.5
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5010164825
400/3ph/5013204825
400/3ph/5021309633
400/3ph/502540
10234
400/3ph/5042609633
400/3ph/505070
10234
400/3ph/5084
1259633
Nominal air flowFan external resistance (standard)
m3/hPa
40000
50000
55000
110000
140000
220000
280000
Water flow ±10%Pressure drop (water)Water connections
l/minm hdinch
334.2
1½ BSPF
334.2
1½ BSPF
662.1
1½ BSPM
664.5
1½ BSPM
1333.4
1½ BSPM
1664.5
1½ BSPM
2665.3
2 BSPMCompressorFanSound pressure level @ 3mProduct size (w x d x h)Weight
TypeTypedB(A)mmkg
1 x Scroll1 x Axial
481264 x 600 x 725
131
1 x Scroll1 x Axial
521264 x 600 x 725
145
1 x Scroll1 x Axial
621525 x 790 x 1080
219
1 x Scroll1 x Axial
641665 x 1060 x 1310
329
2 x Scroll1 x Axial
681810 x 1190 x 1310
549
2 x Scroll2 x Axial
702065 x 1190 x 1330
599
4 x Scroll2 x Axial
712210 x 1650 x 1340
1065
WAT E R CO O L I N G – A I R CO O L E D H E AT P U M P S
CO M M E R C I A L
Options
�Available in 60Hz
Cooling output and input calculated at +45°C/50% RH ambient air
46
T H E C H A L L E N G EAtmospheric air contains moisture which is a problem to materials and manufacturing processes.
Protect your environment
Even when you cannot see it, moisture in the form of water vapour is all around us, held in suspension in the air. The relative humidity of the air in many cases determines the extent of corrosion of certain materials, the speed at which moulds develop and the rate of increase of bacteria that cause decay. Most materials and goods are best stored under cool dry conditions.
Corrosion speed of steel
Relative humidity
Relative humidity (RH) is the expression used to define how much water vapour can be held in the air at a given temperature as a percentage of what it could contain at saturation (100% RH). That is when the relative humidity reaches the level at which air can hold no more moisture. The maximum amount can vary according to its temperature – warmer air is capable of holding more moisture than colder air.
A false economy
Traditionally the problem was disguised by the use of heat or ventilation. This process is exceptionally energy inefficient and reliant on introducing outside air that is generally not suitable unless expensively heated. Drying by traditional heating involves continuously warming a stream of outside air on a constant ‘in and out’ cycle.
100
12
9
6
3
020 40 60 80
Relative humidity in %
Rust
incr
ease
in 5
5 da
ys, g
ram
mes
per
squ
are
met
re
With an RH of over 60% the rate of corrosion on steel rises rapidly
At an RH of approximately 50% virtually no corrosion occurs
46
47
TO
HE
AT
47
A better way
Dehumidification is much more sophisticated than heating. It recirculates the same air and physically removes moisture from it. This alleviates the need to continuously reheat incoming air. Not only that, a dehumidifier will cleverly convert energy taken out of the room as moisture (latent energy), to create ‘sensible energy’ that can be used to heat the room, accelerating the drying process.
Problem solved
Our wide range of units and operating temperatures ensure there is a system to fit every need. From high tech problems requiring sophisticated ‘total loss’ or ‘keep dry recirculation’ systems to a simple off the shelf mobile dehumidifier to plug in and go – our Calorex sales team are unique problem solvers in their field.
T H E S O LU T I O NThe answer to this problem is Calorex's wide range of dehumidifiers suitable for every environment from warehouses and sub-stations to data centres, museums and garages.
Humid Air Dry, WarmAir
Expansion
Evaporator Condenser
Condensateto waste
20˚C28˚C
80%40%
Compressor
How a Calorex dehumidifier works
The process of dehumidification involves moisture-laden air being drawn into a dehumidifier where the air passes across a refrigerated coil. The air is rapidly cooled below its dew point, condensing the water vapour and recovering its latent heat energy for re-use. The cooled air is then passed across the condenser where it is reheated and returned to the served area at the required lower relative humidity.
47
Take control of humidity and condensation with our leading range of dehumidifiers.
48
Refrigerant dehumidifier
The process of dehumidification involves moisture-laden air (return air) being drawn into a dehumidifier where the air passes across a refrigerated coil. The air is rapidly cooled below its dew point, condensing the water vapour and recovering its latent heat energy for re-use. The cooled air is then passed across the condenser where it is reheated and (supply air) returned to the served area at the required lower humidity.
Advantages:
�Low energy consumption
�Minimal maintenance required
�High specific moisture extraction (kg/kWh)
�Easy installation
�Small diameter condensate drain
Disadvantages:
�Low performance in cold conditions below 3°C
�Smaller dehumidifiers less suitable for ducting
Where used:
Generally, in recirculation applications where the humidity requirement is above 40% RH.
�Preservation during storage
�Data centres
�Substations and switch gear rooms
�Clothes drying
�Food drying
�Swimming pools
Where not used:
�Single pass (total loss) ventilations systems
�Below 40% RH
�Below 3°C
�Explosive environments
Desiccant dehumidifier
The air to be dehumidified (process air), passes through a slowly rotating silica gel rotor. The desiccant material attracts the moisture to its surface, removing it from the air stream (dry air). A second, smaller air stream (reactivation air) usually heated to around 120°C, is required to remove the moisture from the rotor. This (wet) air must then be exhausted to atmosphere using a duct. Slowly rotating the rotor through both airstreams creates a continuous dehumidification process.
Advantages:
�High moisture removal rate in a single air pass
�Can achieve very low absolute humidity levels
�Can work in low temperatures
�Can work in very low humidity
Disadvantages:
�High energy consumption
�Low specific moisture extraction (kg/kWh)
�Ducting from/to outside for reactivation air and wet air
�High rotor replacement costs
Where used:
Generally, where a very low relative humidity or absolute humidity is required, and/or where the operating temp is below 3°C.
�Pharmaceutical
�Food
�Confectionery
�Specialist manufacturing that requires very low RH
�Low temp storage and freezer rooms
Where not used:
�Recirculation applications that require RH above 40%
�Applications that are sensitive to high supply air temperature
�Swimming pools
�Sites with limited power supply (unless mains gas or steam reactivation is available)
�Areas that have no access to outside walls
T E C H N O LO G I E S
R E F R I G E R A N T V S D E S I CC A N T
Humid Air Dry, WarmAir
Expansion
Evaporator Condenser
Condensateto waste
20˚C28˚C
80%40%
Compressor
Humid Air Warm Dry Air
Rotor
Warm VeryHumid Air Fresh Air
60% REACTIVATION AIR
DRY AIR
WET AIR
PROCESS AIR
20°C50°C
40%
Heater
60%
20°C
38°C
9%
Unlike most suppliers, the Dantherm Group product ranges include both refrigerant AND desiccant drying equipment. With products that span both technologies, we can offer impartial advice that provides a solution specifically suited for your application.
49
TO
DR
Y
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 15Features
�Compact design for installation in small areas
�Self contained with fully automatic operation
�Integral humidistat
�Tamper proof controls
�Epoxy polyester painted zintec steel cabinet
�Hot gas defrost for low temperature operation
�Air filter
Applications
� Drying rooms
� Public buildings
� Changing rooms
� Store rooms
� Modular buildings
� Stairwells, cellars and basements
� Museums and galleries
� Unheated premises
� Garages
Specifications Units DH 15AX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Product size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
mmkg
mm ID
0-35150.9225
053
R407c230/1ph/50
0.433.81018
825 x 363 x 3203310
Options
�Through the wall version
Performance data
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 5 10 15 20 25 30
40% 50% 60% 70%
80%
1.0
0.9
0.8
0.7
0.6
0.5
0.60
0.55
0.50
0.45
0.40
0.35
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
OTW15
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120 140 160 180
5.9
5.2
4.2
3.4
2.7
2.1
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
DH110
40% 50% 60% 70% 80%
50
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 30Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Hot gas defrost for low temperature operation
�Quiet centrifugal fans
�Remote humidistat and on/off function
Applications
� Drying rooms
� Modular buildings
� Electrical sub-stations
� Sports clubs and changing rooms
� Warehousing and storage
� Museums, libraries and galleries
� Garages
Specifications Units DH 30AX DH 30AXP
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm ID
0-35301.9700
052
R407c230/1ph/50
0.754.410
15.8Optional LPHW
3.05.0
782 x 270 x 6484016
0-35301.9700
052
R407c230/1ph/50
0.7512.720
15.8Standard Electric
2.0-
782 x 270 x 6484016
Options
�Through the wall version
�Electric air heater
�Floor stand kit
Performance data
15˚C
10˚C
Litres/24 hours0 5 10 15 20 25 30
0.6
0.5
0.40
0.35
*AT 60% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 10 20 30 40 50 60
2.15
1.9
1.7
1.5
1.35
1.2
0.8
0.75
0.7
0.65
0.6
0.55
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH30
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120
4.1
3.5
3.1
2.6
2.3
1.9
1.3
1.2
1.1
1.0
0.9
0.8
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH60
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 5 10 15 20 25 30
0.8
0.7
0.6
0.5
0.50
0.45
0.40
0.35
*AT 60% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 10 20 30 40 50 60
2.15
1.9
1.7
1.5
1.35
1.2
0.8
0.75
0.7
0.65
0.6
0.55
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH30
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
4.1
3.5
3.1
2.6
2.3
1.9
1.3
1.2
1.1
1.0
0.9
0.8
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH60
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
51
TO
DR
Y
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 60Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Hot gas defrost for low temperature operation
�Quiet centrifugal fans
�Remote humidistat and on/off function
Specifications Units DH 60AX DH 60AXP
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm ID
0-35603.5
12800
54R407c
230/1ph/501.27.51330
Optional LPHW5.05.0
1247 x 270 x 6486016
0-35603.5
12800
54R407c
230/1ph/501.2
24.23230
Standard Electric4.0-
1247 x 270 x 6486016
Applications
� Archives and museums
� Churches
� Changing rooms
� Waterworks
� Garages and car storage
Options
�Through the wall version
�Electric air heater
�Floor stand kit
Performance data
15˚C
10˚C
Litres/24 hours0 5 10 15 20 25 30
0.6
0.5
0.40
0.35
*AT 60% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 10 20 30 40 50 60
2.15
1.9
1.7
1.5
1.35
1.2
0.8
0.75
0.7
0.65
0.6
0.55
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH30
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120
4.1
3.5
3.1
2.6
2.3
1.9
1.3
1.2
1.1
1.0
0.9
0.8
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH60
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 5 10 15 20 25 30
0.8
0.7
0.6
0.5
0.50
0.45
0.40
0.35
*AT 60% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 10 20 30 40 50 60
2.15
1.9
1.7
1.5
1.35
1.2
0.8
0.75
0.7
0.65
0.6
0.55
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH30
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
4.1
3.5
3.1
2.6
2.3
1.9
1.3
1.2
1.1
1.0
0.9
0.8
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH60
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
52
D E H U M I D I F I E R S
F LO O R S TA N D I N G
D H 110 Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Stove enamelled aluminium cabinet
�Hot gas defrost for low temperature operation
�Quiet centrifugal fans, two speeds
�Remote humidistat and on/off function
Applications
� Data centres
� Warehousing and storage
� Museums, archives, art galleries, offices
� Sports halls and gyms
Specifications Units DH 75AX DH 110AX DH 110BX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (brass compression)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-35864.0
11800
53R407c
230/1ph/501.59.51355
Optional LPHW8.99.6
1520 x 385 x 79614315
5-351085.2
11800
53R407c
230/1ph/502.1
12.02066
Optional LPHW8.99.6
1520 x 385 x 79614415
5-351085.2
11800
53R407c
400/3ph/502.05.51030
Optional LPHW8.99.6
1520 x 385 x 79614415
Performance data DH 75
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120 140 160 180
5.9
5.2
4.2
3.4
2.7
2.1
2.5
2.1
1.8
1.6
1.4
1.3
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH110
40% 50% 60% 70% 80%
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120 140 160
4.8
4.0
3.3
2.8
2.3
1.7
1.6
1.5
1.4
1.3
1.2
1.1
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*40% 50% 60% 70% 80%
Options
�Through the wall version
�LPHW air heater
�Remote humidistat
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120 140 160 180
5.9
5.2
4.2
3.4
2.7
2.1
2.5
2.1
1.8
1.6
1.4
1.3
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH110
40% 50% 60% 70% 80%
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 20 40 60 80 100 120 140 160
4.8
4.0
3.3
2.8
2.3
1.7
1.6
1.5
1.4
1.3
1.2
1.1
*AT 60% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*40% 50% 60% 70% 80%
Performance data DH 110
53
TO
DR
Y
H I G H C A PA C I T Y D E H U M I D I F I E R S
F LO O R S TA N D I N G
D H 150
Features
�Self contained with fully automatic operation
�Integral humidistat
� Constant flow fan – automatically adjusts to ducting
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Hot gas defrost for low temperature operation
For options see page 55
Applications
� Warehousing and equipment storage
� Metal and spare parts storage
� Electrical sub-stations
� Museums and furniture storage
� Car storage facilities
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
7.0
6.2
5.4
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 200 400 600 800 1000 1200
43
38
34
29
25
22
13.0
12.0
11.3
10.5
9.8
9.0
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
9.4
8.2
7.0
6.2
5.4
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
Air
tem
pera
ture
˚C
43
38
34
29
25
13.0
12.0
11.3
10.5
9.8
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
10.8
9.4
8.2
7.0
6.2
5.4
3.2
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
Air
tem
pera
ture
˚C
43
38
34
13.0
12.0
11.3
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
Performance data
Specifications Units DH 150AX DH 150BX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLA (electrical)Maximum supply fuseLRA (compressor start)LRA (compressor soft-start)Heater typeHeat outputPower supplyFLA (heater)Maximum fuse sizeProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAAA
OptionalkW
V/HzAA
mmkg
inch
0-351507.4
25000-200
58R407c
230/1ph/502.521306128
Top box electric9
230/1ph/503650
660 x 660 x 1313130
¾ BSPM
0-351507.4
25000-200
58R407c
400/3ph/502.511163013
Top box electric9
400/3ph/501216
660 x 660 x1313130
¾ BSPM
54
H I G H C A PA C I T Y D E H U M I D I F I E R S
F LO O R S TA N D I N G
D H 300 BY
Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Reverse cycle defrost for very low temperature operation
For options see page 55
Applications
� Warehousing and equipment storage
� Metal and spare parts storage
� Electrical sub-stations
� Museums and furniture storage
� Car storage facilities
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
7.0
6.2
5.4
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 200 400 600 800 1000 1200
43
38
34
29
25
22
13.0
12.0
11.3
10.5
9.8
9.0
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
9.4
8.2
7.0
6.2
5.4
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
Air
tem
pera
ture
˚C
43
38
34
29
25
13.0
12.0
11.3
10.5
9.8
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
10.8
9.4
8.2
7.0
6.2
5.4
3.2
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
Air
tem
pera
ture
˚C
43
38
34
13.0
12.0
11.3
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
Performance data
Specifications Units DH 300BY
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)LRA (compressor soft-start)Product size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAAA
mmkg
inch
-15 - +3530014.75000
6066
R407c400/3ph/50
6.71924
10134
980 x 826 x 1475220
1½ BSPM
55
TO
DR
Y
H I G H C A PA C I T Y D E H U M I D I F I E R S
F LO O R S TA N D I N G
D H 600
Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Reverse cycle defrost for very low temperature operation
For applications see page 53
Options
� Top or rear fan outlet (DH 150/600 only)
� High pressure fan
� Return air filter
� Condensate pump
� Compressor soft start
� Top discharge box
� Heat recovery to water
� External condenser unit
� Remote humidistat
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
7.0
6.2
5.4
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 200 400 600 800 1000 1200
43
38
34
29
25
22
13.0
12.0
11.3
10.5
9.8
9.0
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
9.4
8.2
7.0
6.2
5.4
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
20˚C
15˚C
Air
tem
pera
ture
˚C
43
38
34
29
25
13.0
12.0
11.3
10.5
9.8
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 50 100 150 200 250 300
10.8
9.4
8.2
7.0
6.2
5.4
3.2
3.0
2.8
2.7
2.6
2.5
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
35˚C
30˚C
25˚C
20˚C
15˚C
10˚C
Air
tem
pera
ture
˚C
Litres/24 hours0 100 200 300 400 500 600
22.4
19.8
17.5
15.1
13.3
11.4
6.8
6.2
5.9
5.5
5.1
4.7
*AT 75% RH
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH300
35˚C
30˚C
25˚C
Air
tem
pera
ture
˚C
43
38
34
13.0
12.0
11.3
SENSIBLE HEATOUTPUT kW* TO AIR
ELECTRICALINPUT kW*
DH600
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
30% 40% 50% 60% 70% 80%
Performance data
Specifications Units DH 600BY
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)LRA (compressor soft-start)Product size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAAA
mmkg
inch
-15 - +3560029.79000
8063
R407c400/3ph/50
102635
13555
1730 x 1250 x 1600497
1½ BSPM
56
Specifications Units AA 600 AA 900 AA 1200 AA 1500
Air flowExternal available static pressureFresh air flow (option)External available staticDehumidifcation @ 30oC/60% RHDehumidifcation @ 30oC/70% RH
m3/hPa
m3/hPal/hl/h
2000330
0-9001004.65.5
2500220
0-9001006.57.8
3500290
0-9001008.5
10.8
4300350
0-90010010.113.2
Heat to airNet via heat pumpVia standard LPHW @ 80oCMax available (heat pump + standard LPHW)Via upgraded LPHW @ 55oCMax available (heat pump + upgraded LPHW)
kWkWkWkWkW
5.111.014.09.4
12.7
7.113.518.611.516.9
10.024.030.020.427.0
14.028.036.023.836.8
Nominal power consumed kW 2.1 2.8 3.6 4.7
AA denotes heat recovery to air and optional LPHW heater for air only
Features
� Dynamic heat pump heat recovery
� Constant flow EC fan (models 600, 900, 1200)
� Speed controllable EC fan (model 1500)
� PLC control with 3.5" touchscreen user interface
� Remote monitoring/control
Options
� Fresh air module
� Integral LPHW heat exchanger for air heating
� Upgraded LPHW heat exchanger for air
� Electric resistance air heaters (6/12/18kW)
� Air cooling with remote condenser
Applications
�Data centres
�Electronic equipment rooms
�Sensitive materials storage
Electrical heater option notes
� In lieu of LPHW heat exchangers
� 6kW or 12kW is available for 600 and 900 models
� 12kW or 18kW is available for 1200 and 1500 models
TO U C H S C R E E N
H I G H C A PA C I T Y D E H U M I D I F I E R S
D U C T E D
57
TO
DR
Y
H I G H T E M P E R AT U R E P R O C E S S D R Y I N G
F LO O R S TA N D I N G
Features
�Rapid moisture removal at lowest cost per litre extracted
�Latent energy reclaimed to reduce power consumption
�Drying at lower temperatures reduces risk of heat damage
�Even drying improves product quality
�Low maintenance
Options
�Range of Calorex control panels
�Stainless steel cabinet
�Steam or LPHW heat exchangers for initial heat input
�Castors for portability to aid cleaning and maintenance
�Air inlet filters
Applications
� Ceramics and timber
� Confectionery and food manufacturing
� Brick, block and tile
� Textiles, paper and cardboard
D H 334
Specifications Units DH 334BH
Operating temperature rangeDehumidification @ 50°C/60% RHHeat to air via dehumidificationHeat to air via resistance heaters and dehumidificationAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumedMin. supply capacityMax. supply fuse Heater ratingFLANominal power consumedLRARLANominal running currentProduct size (w x d x h)Weight
°Cl/hkWkW
m³/hPa
dB(A)
V/HzkWAA
kWA
kWAAA
mmkg
30-701710
18.55800
069
R134a400/3ph/50
14.129359
124.972129
985 x 700 x 1476170
Performance data
20
15
10
5
0
0 10 20 40 60 80 10030 50 70 90
Overheat zone
Overload zone
Defrost zone
30°C
25°C
40°C50°C
60°C
70°C
Air %RH
Litr
es/h
our
Dantherm Ltd.Unit 12, Galliford RoadMaldon CM9 4XDUnited Kingdom +44 (0)1621 [email protected]