8
NPT 16.00 [406] 20.00 [508] 21.25 [540] Displa Window [ 9.35 [237] .63 [16] 3.00 [76] 2X .44 [11] Slot 8.00 [203] 0 [89] 0 [127] 3.00 [76] 2X 1 Inch NPT Port 3.00 [76] 4.00 [102] 3.43 [87] 6.18 [157] View A-A 12.87 [327] A 1 Vertical Flow Applications Horizontal Flow Applications 5.00 ± .25 [127] .5 -13 UNC - 2B, 1.00 U - Length 9.25 ±.25 [235] ø2.06 Max 4.25 [108] 1.50 [38] 1.50 [38] 1 Inch NPT Conduit Port 5.00 [127] 2 Inch NPT 11.50 [292] ] 20.56 Sq. [522] .60 4 PL. [15] 19.75 [502] 10.75 Max 8.59 [218] 3rd Port Pr J16 J16 J15 J15 J14 J14 J13 J13 J12 J12 J11 J11 J10 J10 J9 J9 J8 J8 J7 J7 PO POWER SUPPL WER SUPPL Y 2 1 C O N T R O L L E R S C H S E N S O R I N P U T S C H S E N S O R I N P U T 18.312 18.312 [465] [465] 19.00 19.00 [483] [483] 7.50 7.50 [190] [190] 10.47 10.47 [266] [266] 3 Y N 4 5 6 > . 7 E 0 # H U 8 9 < P FLUID COMPONENTS INTL FLUID COMPONENTS INTL Port 3.43 [87] 6.18 [157] 10.75 [273] 6.50 [165] 12.87 [327] A 5.75 ±.25 [146] .50 [13] 4 PL. .5 - 13 UNC - 2B 1.00 U - Length 11.93 ±.25 [303] 1/2 X" X" (3 Inch Flange) Ve FCI MT Series: Multipoint Mass Flowmeters for Gas or Air Service and CEMS Stack Monitoring. FCI MT SERIES
Transcript
Page 1: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

4X 1 Inch NPT

16.00

[406]

20.00

[508]21.25

[540]

Display

Window[

9.35[237]

.63[16]

3.00[76]

2X .44 [11] Slot8.00[203]

3X 3.50 [89]

5.00 [127]

3.00 [76]

2X 1 Inch NPT Port

3.00[76]

4.00[102]

3.43 [87]

6.18 [157]

View A-A

12.87 [327]

A

1

Vertical

Flow

Applications

Horizontal

Flow

Applications5.00 ± .25

[127]

.5 -13 UNC - 2B, 1.00

U - Length

9.25 ±.25

[235]

ø2.06 Max

4.25[108]

1.50

[38]

1.50[38]

2X 1 Inch NPT Conduit Port5.00[127]

2 Inch NPT

11.50

[292]

[152]

20.56 Sq.

[522]

.604 PL.

[15]

19.75

[502]

10.75

Max

8.59[218]

3rd Port Provided with 6 & 8

J16 J16

J15 J15

J14 J14

J13 J13

J12 J12

J11 J11

J10 J10

J9J9

J8J8

J7J7

PO

PO

WE

R S

UP

PL

WE

RS

UP

PLYY

2211

CCOONNTTRROOLLLLEERR

SSCCHH

SSEENNSSOORR

IINNPPUUTT

SSCCHH

SSEENNSSOORR

IINNPPUUTT

18 .31218 .312

[465 ][ 465 ]

19 .0019 .00

[483 ][ 483 ]

7 . 507 .50

[190 ][ 190 ]

10 .4710 .47

[266 ][ 266 ]

33YY

NN

4455

66>>

..

77

EE00

##HH

UU8899

<< PP

FLUID COMPONENTS INTL

FLUID COMPONENTS INTL

Port

3.43 [87]

6.18 [157]

10.75

[273]

6.50 [165]

12.87 [327]

A

5.75 ±.25

[146]

.50 [13]

4 PL.

.5 - 13 UNC - 2B 1.00

U - Length

11.93 ±.25

[303] 1/2 X"

X"

(3 Inch Flange)

Vertical

FCI MT Series:

Multipoint

Mass Flowmeters for

Gas or Air Service and

CEMS Stack Monitoring.

FC

IM

T

SE

RI

ES

Page 2: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

FCI’s MT Series Multipoint Mass Flowmeters are ideal fortoday's most challenging industrial air or gas handling applicationsand continuous emissions monitoring systems (CEMS). Insidelarge combustion or preheater systems, HVAC units, ducts or flue stacks, MT Series multipoint flowmeters measure flow withexceptional precision under variable thermodynamic conditions.They are an excellent choice for measuring mass flow almostanywhere variable conditions limit single-point flowmeter effec-tiveness. Harsh environments, in which temperature, vibration,abrasion and corrosion pose difficulties for other meters, are no problem for the rugged MT Series multipoint flowmeters.Instrument accuracy is available to ± 2% of reading, withrepeatability of ± 0.5%.

Key Product Performance Features� High accuracy -- up to 16 flow sensing points per meter.� Diagnoses duct temperature stratification with dynamic

temperature output capability.� Wide temperature range from –50° to +850°F [-45° to +454°C].� Pressures up to 50 psig [3.4 bar(g)].� Continuous built-in testing and calibration adjustment prevent

drift for superior repeatability.� Averaging filter dampens response to rapid process fluctuations.� RS232C serial ports for communication with field devices.� Choose 4 to 20 mA, 1 to 5 or 0 to 10 Vdc outputs.� Menu-driven control for ease of service.

� Rack mountable with card slots for expansion and option modules.

� Stainless steel flow element construction; electronics enclosure rated NEMA/CSA Type 4.

� Simple maintenance with modular design and inter-changeable components.

MT86 and MT91 Series Multipoint Flowmeters The MT86 and MT91 Series flowmeters are installed in thou-sands of applications worldwide. The MT91 Series flowmeter ishighly versatile, with a wide turndown range available (from5:1 to 100:1) and flow sensitivity from 0.25 to 150 SFPS [0.08to 46 NMPS]. With its smart digital flow transmitter and advancedthermal dispersion technology flow-sensing elements, the MT91flowmeter meets federal environmental requirements for CEMSper CFR Title 40, Part 75.

The MT86 and MT91 are multipoint flowmeters with sensorarrays of up to 8 (MT86 unit) or 16 (MT91 unit) independentthermal flow sensors with a variable insertion length attached toa junction box and connected via cable to a remote electronicsassembly. Individual flow sensors are placed along a supportassembly to meet application-specific requirements. The flowelement assembly for both the MT86 and MT91 flowmeters isavailable with flanged, threaded or retractable process connectionswith a NEMA /CSA Type 4 junction box or optional explosion-proofflow element enlosure.

Dual sensing point flow element assembly with rack mount MT91 transmitter

Page 3: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

The transmitter package for both the MT86 and MT91flowmeters also is housed in a NEMA/CSA Type 4 or optionalexplosionproof enclosure. The MT86 flowmeter's electronicspackage is connected remotely by cable to the flow elementassembly up to 500 ft [152 m] away, while the MT91 flowmeter'selectronics package is similarly connected up to 1000 ft [305 m]away. The MT91 flowmeter's electronics package is also availablein an optional 19-inch DIN or ANSI /EIA rack mount assembly.

Thermal Flow Sensing Element FCI's advanced flowsensing element design, based on thermal dispersion technology,measures air or gas mass flow with exceptional accuracy andrepeatability over a wide range of temperatures and environmentalconditions. Each all-metal flow element features a fouling immuneno-moving-parts design for simple maintenance and long life.The flow element incorporates two platinum resistance-temper-ature detectors (RTDs) for temperature and flow measurement.All wetted surfaces are 316 stainless steel with nickel brazedjoints per AMS 4777 (standard) or Hastelloy C-276 as an option.Coating materials, such as electroless nickel plating or chromiumcarbide are also available.

Mass flow rate is determined by the MT Series multipointflowmeter in the process stream by heating one of its RTDswhile the other senses the temperature of the flowing media.The temperature differential between the RTDs relates to the

mass flow rate and properties of the process media. Higherflow rates or denser media, for example, cause increased cooling of the heated RTD and a reduction in the temperaturedifferential.

Smart Flow Transmitter The MT91 flow transmitterfeatures a powerful microprocessor-driven design for superiorsignal processing and data collection. The design includes a

5.2 ft.

7.4 ft.

9 ft.

Area A

Area B

Equal-Area Sensing Point Placement

Dual sensing point flow element assembly with remote MT86 transmitter

Page 4: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

user-friendly menu-driven structure with LCD screen and keypadfor programming the control, monitoring, display, and driver/alarm functions. A nonvolatile EEPROM chip stores applicationand calibration data, and protects this data in the event of apower disturbance.

RS232C and HART communication ports offer easy linkswith controllers or other field devices. Signal outputs availableare 4 to 20 mA, 1 to 5 or 0 to 10 Vdc. Other features includereal-time temperature compensation, dynamic process temper-ature indication, built-in testing and self-diagnostics, dynamicconversion, display of application statistics and security safe-guards against unauthorized access or tampering.

Typical Applications� Stack monitoring for Continuous Emissions Monitoring

Systems (CEMS)� Primary air flow monitoring� Air flow monitoring for performance efficiency� Air monitoring to low NOX burners � Combustion air flow monitoring � Flue gas recirculation monitoring � Scrubber and precipitator balancing

Single-pointFlowmeter Output

100%

MT SeriesMultipoint

Flowmeter Output20303020

100%Even Flow Profile

Single-point = Multipoint =Actual Flow

ActualFlow

in Duct100%

Single-pointFlowmeter Output

90%

MT SeriesMultipoint

Flowmeter Output15204025

100%Slightly Irregular Flow Profile

Single-point = 10% ErrorMultipoint = Actual

ActualFlow

in Duct100%

Single-pointFlowmeter Output

75%

MT SeriesMultipoint

Flowmeter Output5

155030

100%Grossly Irregular Flow Profile

Single-point = 25% ErrorMultipoint = Actual

ActualFlow

in Duct100%

� Induced or forced draft fan monitoring � Preheater air to boilers or furnaces � Heavy-duty industrial HVAC

Multipoint Versus Single-point Sensing The unstableair currents and gases, often with particulates, that are found inlarge industrial facility ducts or flue stacks and in air or gas han-dling systems turn the task of mass flow measurement into a complexprocess. This task is often beyond the capabilities of single-pointflowmeters or differential pressure averaging devices.

As depicted in the accompanying illustration below, inaccurateflow rate readings can result when single-point metering instrumentsare used in ducts and stacks where large cross-sectional areas orlimited straight-run lengths create irregular flow profiles.

Designed especially for such air/gas handling systems, the MTSeries offers up to 16 sensing points which meter the mass flowrate of individual segments of the flow stream. Representing thoserates, the signal outputs of each sensor element are summed bythe instrument’s control logic to provide an accurate reading oftotal mass flow rate through the entire duct.

Typical Stack Installation

Page 5: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

MT Series

MT Series

MT Series

MT Series

MT Series MT Series

MT Series

MT Series

AirPreheater

Furnace

Boiler

Scrubber

Exhaust

ForcedDraft Fans

Dampers

To Stack

GasRecirculation

Fan

Improving the Efficiency of Industrial Air/Gas Systemswith the MT Series Multipoint Mass Flowmeters1. Combustion Air and Preheater AirTo keep boilers, furnaces, and cogeneration units operating at maxi-mum efficiency, individual combustion and preheater air flow feedlines are metered with the MT Series.2. Stack EmissionsReliable and accurate measurement of flow from effluent stacksin power, cogeneration, chemical, paper, refinery, and otherindustrial plants is critical to properly calculate total emissions.The MT Series can be used alone or in conjunction with envi-ronmental and/or radiation monitors for this purpose.3. Flue Gas/Scrubber BalancingIndustrial pollution control systems can be operated far moreeffectively by utilizing the MT Series to meter and balance the flowof flue gas through scrubbers, precipitators and bag houses. Ultra-sensitive, the MT Series offers unsurpassed accuracy across broadflow ranges. The unit’s low-profile, no-moving-parts design causesvirtually no pressure drop in large lines, and the optional abra-sion-resistant probe coating provides outstanding protectionagainst fly ash and other particulate matter.

4. Heating, Ventilation & Air ConditioningUltra-low flow sensitivity, wide turndown and easy duct mountingmake the MT Series the choice for HVAC flow metering. Accurate atthe low flow rates typical in such systems, the MT Series not onlymeasures and totals air flow, it can also be used for controllinglouvers to balance flow within the system.

32

4

1

Page 6: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

J16

J15

J14

J13

J12

J11

J10

J9

J8

J7

J6

J5

J4

J3

J2

J1

DIS

PLAY

BO

AR

D

PO

WE

R S

UP

PLY

TB1

PowerSupply

7.30[185]

1.50[38]

Fuse

TB1

21

CONTROLLER

SCH

SENSOR

INPUT

SCH

SENSOR

INPUT

1 8 . 3 1 2[ 4 6 5 ]

1 9 . 0 0[ 4 8 3 ]

7 . 5 0[ 1 9 0 ]

1 0 . 4 7[ 2 6 6 ]

3 Y N

4 5 6 > .

7

E 0 # H U

8 9 < P

1 7 . 2 5[ 4 3 8 ]

FLUID COMPONENTS INTLFLUID COMPONENTS INTL

22.60[574]

13.00[330]

4 X 1 Inch NPT Port [25]

14.00[356]

4.25[108]

3.50[89]

21.75[553]

1.25[32]

Optional Window

3.50[89]

3.50[89]

.68[17]

22.60[574] CL

CL

Remote MT91 Transmitter Assembly -- NEMA/CSA Type 4 and Explosion Proof

Remote MT91 Transmitter -- Rack Mount

FLUID COMPONENTS INTL

4X 1 Inch NPT16.00[406]

(14.00)

20.00[508] 21.25

[540]

DisplayWindow

9.35[237]

10.00[254]

.63[16]

3.00[76]

2X Ø.44 [11]

2X .44 [11] Slot

8.00[203]

3X 3.50 [89]

5.00 [127]

3.00 [76]

[mm]

[mm]

[mm]

Page 7: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

10.75[273]

6.50 [165]

2X 1 Inch NPT Port

3.00[76]

4.00[102]

3.43 [87]

6.18 [157]

View A-A

12.87 [327]

A A11.50[292]

.50 [13]4 PL.

.5 - 13 UNC - 2B 1.00

U - Length

8.93 ±.25[252]

1/2 X"

X"

(3 Inch Flange)

HorizontalFlow

Applications

VerticalFlow

Applications

HorizontalFlow

Applications

VerticalFlow

Applications

3.35 ±.25[85]

.3 -18 UNC - 2B, 1.00

U - Length

7.6 ±.25[193]

ø2.06 Max

4.25[108]

1.50 [38]

1.50[38]

2X 1 Inch NPT Conduit Port

5.00[127]

2 Inch NPT

8.00[203]

(14.00)

11.50 [292]

10.75[273]

6.00[152]1.00

[25.4]

MT Series Flow Element Assembly -- Explosion Proof

MT Series Flow Element Assembly -- NEMA/CSA Type 4

3.75[95]

2 x 1 Inch NPT Conduit Port

12.50[318]

1 Inch NPT Port

17.87[454]

4X ø.31[8]

1.50[38]

14.93[379]

6.12[155]

11.00[279] 3rd Port Provided with 6 & 8

Point Systems

Shown withOptional RateDisplay &Totalizer

2.25[57]

(14.00)

16.75[425]

12.00[305]

Remote MT86 Transmitter Assembly -- NEMA/CSA Type 4 and Explosion Proof20.56 Sq.

[522]

11.00[279]

2 X 1 Inch NPT Port

.604 PL.[15]

19.75[502]

10.75[273] Max

8.59[218]

4.03 [102]

4.25[108]

4.78[121]

Shown with Optional RateDisplay & Totalizer

3rd Port Provided with 6 & 8Point Systems

6.53[166]

[mm]

[mm]

[mm]

[mm]

Page 8: 22313 MT Series Bro-F 11278 - Applied Measurement and Controlappliedmc.com/content/images/MT-Brochure.pdf · 2008-10-01 · The transmitter package for both the MT86 and MT91 flowmeters

©Copyright 2006 by Fluid Components International LLC. All rights reserved. Subject to change without notice. Doc. No. 02MK011278H0606-4K

Flow ElementProcess Connection: 2 inch male NPT or 3 inch, 150 lb. raisedface carbon steel flange. Other flange sizes and materials available.Insertion Length: Variable insertion lengths; customer specified.Materials of Construction: All wetted surfaces are 316 stainlesssteel nickel brazed per process specification AMS 4777. HastelloyC-276 is also available. Electroless nickel or chromium carbideplating is also available.Number of Sensing Points per System: Up to 8 points, total.Flow Range: 0.25 to 150 SFPS [0.08 to 46 NMPS] in air at stan-dard conditions of 70°F and 14.7 psia [20°C and 1.013 bar(a)].Consult factory or manufacturer’s representative for applicationinformation pertaining to gases other than air.Enclosure: NEMA/CSA Type 4 and equivalent to IP66, optionalexplosion-proof, groups B, C, D - Divisions 1 and 2.Operating Temperature:

Standard: -50° to +350°F [-45° to +177°C]Optional: -50° to +850°F [-45° to +454°C]

Operating Pressure: To 50 psig [3.4 bar(g)]Design Pressure: To 500 psig [34 bar(g)]

Transmitter� MT86Analog Outputs:

Standard (1 output): 4 to 20 mA, 1000 watts maximumOptional (up to 4 outputs): 10 to 50 mA, 400 watts maximum

0 to 5 Vdc, 2 mA maximum1 to 5 Vdc, 2 mA maximum 0 to 10 Vdc, 2 mA maximum

Relay Outputs: Dual DPDT alarm: 2 amp contact rating optional.Input Power:

Standard: 115 Vac, 50/60 Hz, 50 watts maximum, 1/2 amp fuseOptional: 230 Vac, 50/60 Hz, 50 watts maximum, 1/4 amp fuse

100 Vac, 50/60 Hz, 50 watts maximum, 1/2 amp fuse24 Vdc, 1.5 amp fuse

Enclosure: Remote NEMA/CSA Type 4 and equivalent to IP66.Explosion-proof optional.Conduit Connection: 1 inch female NPTLCD Display: OptionalOperating Temperature:

Without LCD Display: -50° to +150°F [-45° to +66°C];With LCD Display: 0° to 150°F [-18° to +66°C]

Accuracy: ±2% rdg, ±0.5% full scale.Repeatability: ±1% of reading.Turndown: 5:1 to 100:1 maximum

Transmitter� MT91Analog Outputs: Dual module, field programmable for flow ortemperature outputs configured as:

4 to 20 mA into a maximum of 600 watts, or0 to 10 Volts into a minimum of 5000 watts, or1 to 5 Volts into a minimum of 2500 watts

Relay Outputs: Dual DPDT alarm: 2 amp contact rating. Field programmable for flow, temperature, or sensing point fault.Input Power: 85 to 265 Vac, 47 to 63 Hz, 3.5 amp fused; 20 to 32Vdc, 24 Vdc nominal. Consult factory for special power requirements.Enclosure: Remote NEMA/CSA Type 4 and equivalent to IP66 electricalenclosure. Optional 19 inch rack in accordance with DIN 41494part 1, ANSI/EIA-RS-310C.Conduit Connection: 1 inch female NPT.Communication Port: RS-232C or HART.Operating Temperature:

With local display: 32° to 140°F [0° to 60°C]Without local display: 0° to 140°F [-18° to 60°C]

LCD Display: 4 lines by 20 characters/line. Menu driven systemprompts the user for system commands.Keypad: 20 keys provide easy touch programming for changingzero, span, switch points, units of measure, etc.

Flow Accuracy:For ±30°F [±17°C] range: ±2% reading or ±0.2 SFPS [± 0.06 NMPS]For over ±100°F [±55°C] range: ±4% reading or ±0.5 SFPS[±0.15 NMPS]Flow Repeatability: ±0.5% reading.Turndown: 5:1 to 100:1 maximum. Stated flow performance from 1 to 100 SFPS [0.3 to 30 NMPS].Contact factory for accuracy in applications beyond this flow range.

Temperature Output Accuracy: For 32° to 212°F [0° to 100°C]: ±0.9°F [±0.5°C]For < 32°F [0°C] and/or > than 212°F [100°C]: ±1.8°F [±1°C]Temperature Output Repeatability:For 32° to 212°F [0° to 100°C]: ±0.2% readingFor < 32° F [0°C] and/or > 212°F [100°C]: ±0.5% readingStated temperature performance at a minimum flow rate of 5 SFPS [1.5 NMPS]. Contact factory for accuracy of temperatureindication when flow rate is below 5 SFPS [1.5 NMPS].

Calibration -- MT86 and MT91Performed on NIST traceable equipment.

MT86 and MT91 Multipoint Mass Flowmeter Specifications

Web: www.fluidcomponents.com 1755 La Costa Meadows Drive, San Marcos, California 92078 USA | Phone: 760-744-6950 | Toll free: 800-854-1993 | Fax: 760-736-6250

European Office: Persephonestraat 3-01 5047 TT Tilburg, The Netherlands | Phone: 31-13-5159989 | Fax: 31-13-5799036ISO 9001:2000 and AS9100 certified


Recommended