437
FAP WALL THERMOSTATS
WALL THERMOSTATSROUND SERIES
24 VOLT HEATING/COOLING THERMOSTAT AND SUB- BASES... SINGLE STAGE
THERMOSTATS
• FOR HEATING ONLY WITHOUT SUB-BASE• QUIET SPDT MERCURY SWITCH• HEATING ANTICIPATOR: .1-1.2 AMP ADJ• INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING
SCREWS• 1H/1C WITH SUB-BASES LISTED BELOW
SUB-BASES
• PROVIDE MOUNTING AND MANUAL SWITCHING FORHH01AD060
• FAN SWITCH: ON-AUTO• COOLING ANTICIPATOR: FIXED
P/N LOGOHH01AD060 HONEYWELLHH621201 BRYANTHH621401 PAYNE
P/NGENERAL
USEAUTOFAN
SYSTEMSWITCH
HH93AZ050GAS/ELECTRIC
SPLIT SYSTEMS &SELF CONTAINED
COOLINGONLY
COOLOFFHEAT
HH93AZ051HP, COOLING
WITH ACCESSORYELECTRIC HEAT
HEATING &COOLING
COOL OFFHEAT
HH93AZ053COOLING ONLY
SYSTEMCOOLING
ONLY
COOL OFFHEAT
HH93AZ055COOLING ONLY
SYSTEMCOOLING
ONLY
COOL OFF
ONLY
P564
STANDARD SERIES24 VOLT HEATING/COOLING THERMOSTAT...SINGLE STAGES
FOR USE ON:
• QUIET SPDT MERCURY BULB SWITCH• HEATING ANTICIPATOR: .18-10 AMP
P/N LOGOGENERAL
USEAUTO FAN
OPERATION
HH07AT184 CARRIER
GAS/ELECTRICSPLIT SYSTEMS
ANDSELF-CONTAINED
COOLING ONLYEXTRA HTG. & CLG.
TERMINALS:HEATING ONLY
HH07AT183 BDP
GAS/ELECTRICSPLIT SYSTEMS
ANDSELF-CONTAINED
COOLING ONLYEXTRA HTG. & CLG.
TERMINALS:HEATING ONLY
HH641601 HONEYWELL
GAS/ELECTRICSPLIT SYSTEMS
ANDSELF-CONTAINED
COOLING ONLYEXTRA HTG. & CLG.
TERMINALS:HEATING ONLY
P563
438
FAP WALL THERMOSTATS
WALL THERMOSTATSHEAT ONLY THERMOSTAT24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASES... SINGLE STAGE
THERMOSTAT
• FOR HEATING ONLY WITHOUT SUB-BASE • 1H/1C WITH SUB-BASE LISTED BELOW• QUIET SPDT MERCURY SWITCH• HEATING ANTICIPATOR:.1-1.2 AMP ADJ.• INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING
SCREWS
WITH CARRIER LOGO
SUB-BASE
• PROVIDES MOUNTING AND MANUAL SWITCHING FOR THERMOSTAT
• SYSTEM SWITCH: COOL - OFF - HEAT• FAN SWITCH: ON - AUTO• COOLING ANTICIPATOR: FIXED
FOR USE ON:
P/N: HH01AD040
P/NGENERAL
USE
AUTOFAN
OPERATION
HH93AZ040
GAS ELECTRICSPLIT SYSTEMS
ANDSELF-CONTAINED
COOLINGONLY
P566
SPECIAL HEAT PUMP SERIES24 VOLT HEATING/COOLING THERMOSTATS AND SUB-BASES
THERMOSTAT
• SILENT, DUST-FREE MERCURY SWITCHES• SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND
COOLING• SUB-BASE REQUIRED FOR MOUNTING, AND FOR SYSTEM AND
FAN SWITCHING• PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO
SUB-BASE• COVER HAS TAPPED HOLES FOR LOCKING SCREWS
SUB-BASES
• FOR USE WITH SPECIAL HEAT PUMP THERMOSTAT• PROVIDE WIRING TERMINALS, MOUNTING BASE AND SYSTEM/FAN
SWITCHING• EMERGENCY HEAT INDICATOR LIGHT• MOUNT ON WALL OR HORIZONTAL OUTLET BOX
P/N USE ON SUB-BASESYSTEMSTAGES
H/CANTICIPATORS
HH07AT171HH93AZ175
338QTHEAT PUMPS
ONLYHH93AZ171
1H/1C2H/2C
FIXED
HEATPUMPS
CHANGE-OVER TYPE
SWITCH POSITIONSP/N
SYSTEM FAN
38AND
MISC.
AUTOON,OFFSUPL HT
ON,AUTO
HH93AZ173
MANHT, COOL
SUPL HT, OFFON,
AUTO,HH93AZ175
38SQAND
TECH2000
AUTOSUPL HT,
ON, OFFON,
AUTOHH93AZ183
MANSUPL HT,
HT, OFF, COOLON,
AUTOHH93AZ186
50QTONLY
MANHEAT,COOL
SUPL HT, OFFON,
AUTOHH93AZ171
P567
439
FAP WALL THERMOSTATS
WALL THERMOSTATS (HONEYWELL)MULTI-STAGE SERIES THERMOSTATS
• 24 VOLT HEATING/COOLING THERMOSTAT• SILENT, DUST FREE MERCURY SWITCHES• SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND
COOLING• SUB-BASE REQUIRED FOR MOUNTING• PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO SUB-BASE• COVER HAS TAPPED HOLES FOR LOCKING SCREWS• ANTICIPATORS:1ST AND 2ND STAGES
HEAT:.1-1.2 AMP ADJUSTABLECOOL:FIXED
• GENERAL USE: LOW VOLTAGE CONTROL OF MULTI-STAGE HEATING, COOLING, AND HEATING-COOLING SYSTEMS INCLUDING HEAT PUMPS
SYSTEM STAGESP/N LOGO
HEAT COOL2 1 HH07AT170 CARRIER LOGO2 2 HH07AT172 CARRIER LOGO1 1 HH07AT174 CARRIER LOGO2 1 HH621603 HONEYWELL LOGO2 2 HH621606 HONEYWELL LOGO1 1 HH621602 HONEYWELL LOGO
MATCHING SUB-BASES
• FOR MULTI-STAGE THERMOSTATS HH07AT170, 172, 174• PROVIDE WIRING TERMINALS, MOUNTING BASE, AND SYSTEM AND FAN SWITCHING MOUNT ON WALL OR HORIZONTAL OUTLET BOX
*A = Fan circuit energized automatically during cooling cycle only.B = Fan circuit energized automatically during cooling and heating cycles.C = Removable jumper for use on two-transformer systems.D = Extra terminal provided for heating circuit.
CHANGEOVER TYPESPECIAL
FEATURES* P/N
AUTOMATIC MANUALSWITCH POSITIONS
SYSTEM FANNONE HEAT COOL AUTO OFF EMER-HEAT NONE ON, AUTO
� � � � � � � � A, F HH93AZ174� � � � � � � A, C, D HH93AZ176� � � � � � � A, C, G HH93AZ177
� � � � � B, C, E, G HH93AZ179� � � � � A, C, E HH93AZ184
P567
E = Extra terminal provided for heating and cooling circuits.
F = Indicator light for emergency heat.G = Indicator for lock-out or lockout.
440
FAP WALL THERMOSTATS
WALL THERMOSTATS (HONEYWELL)CLOCK THERMOSTAT
• 24 VOLT HEATING/COOLING CLOCK THERMOSTAT• EQUIPPED WITH A RECHARGEABLE BATTERY TO POWER THE
QUARTZ CLOCK• PROVIDES COMPLETE AUTOMATIC HIGH AND LOW• TEMPERATURE CONTROL WITH UP TO THREE SET-
BACK/SET-UP PERIODS• HEAT ANTICIPATOR IS ADJUSTABLE FROM.1 TO 1.2 AMP FOSSIL
FUEL HEATING WALL PLATE IS INCLUDED WITH EACH THERMOSTAT.
THERMOSTAT WITH CARRIER LOGO
SUB-BASES
• MANUAL CHANGEOVER
WALL PLATE
HH99AZ161 – for L.P. Gas
P/N: HH10AD144
P/NFAN
SWITCHSYSTEMSWITCH
HH93AZ160 ON-AUTO HEAT-OFF-COOLSINGLE
TRANSFORMERSYSTEMS
HH93AZ161 ON-AUTO HEAT-OFF-COOLINDEPENDENT
HEAT-COOLSYSTEMS
P562
WALL HUMIDISTAT
Humidistat has outdoor temperatures and corresponding recom-mended humidity settings on face plate for reference.
ADAPTER PLATE
P/N: HL38MG026
P/N: HH92AZ001
• RANGE 10-60%• POSITIVE ON AND OFF
POSITION• ELECTRICAL• RATING:• 50 VA @ 24 VOLT• NYLON SENSING
ELEMENTP591
• THIS ADAPTER PLATE IS USED WITH T87F THERMOSTAT
• COVERS OLD THERMOSTAT MOUNTING MARKS
• 5-1/2 IN. DIAMETER
P565
441
WHITE-RODGERS WALL THERMOSTATS
.COMFORT-SET 11 DIGITAL THERMOSTATS WITH AUTOMATIC CHANGEOVER
COMFORT-SET 11 DIGITAL THERMOSTATS
• AUTOMATIC HEAT/COOL CHANGEOVER ALLOWS YOU TO SET THE SYSTEM SWITCH IN ONE POSITION ALL YEAR
• SIMULTANEOUS HEATING AND COOLING PROGRAM STORAGE ELIMINATES THE NEED TO REPROGRAM AS THE SEASONS CHANGE
• PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS
• FOUR SEPARATE TIME/TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS
• COMPUTED EMRTM (ENERGY MANAGEMENT RECOVERY) PROGRAM ALLOWS FOR A HEAD START ON RECOVERY FROM SETBACK OR SETUP PROGRAM TEMPERATURE IS REACHED WHEN DESIRED
• PROGRAMMABLE FAN CONTROL PERMITS CONTINUOUS FAN DURING ANY GIVEN PROGRAM PERIOD
• BACKLIT DISPLAY - ENERGIZES WHENEVER THE KEYPAD OR TEMPERATURE BUTTONS ARE PRESSED
• AUDIO PROGRAM PROMPTING - THERMOSTAT BEEPS TO SIGNAL THAT A CHANGE HAS BEEN MADE
• BATTERY BACKUP CAPABILITY - SUPPLIED WITH THREE “AA” EVEREADY ALKALINE BATTERIES
• KEYPAD LOCKOUT• ELIMINATES NEED FOR ISOLATION RELAYS• COMPATIBLE WITH 3-WIRE ZONE OR 750 MILLIVOLT SYSTEMS• SUITABLE FOR USE ON CENTRAL ELECTRIC HEAT SYSTEMS WHERE BLOWER
IS ENERGIZED BY FAN RELAY ON HEAT AND COOL• REMOTE SENSING - WHEN USED WITH F145-1049 REMOTE SENSOR (ORDER
SEPARATELY)• “HOLD TEMP” KEY PROVIDES MANUAL OVERRIDE OF PROGRAM • °F/ °C DISPLAY• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING• COMPRESSOR SHORT CYCLE PROTECTION• TEMPERATURE SET-POINTS RESET AND HOLD AT 64° F IN HEATING OR 82° F
COOLING IN CASE OF POWER FAILURE AND NO BATTERY BACKUP• ARM-CHAIR PROGRAMMING• RED LED INDICATOR LIGHT GLOWS WHENEVER THE HEATING, COOLING OR
FAN IS IN OPERATION
P/N: 1F90-0711F97-071
1F90-071 SHOWN
1F97-071 SHOWN
P569
P569
• DUAL PROGRAM STORAGE ON ALL HEAT AND COOL MODELS.• BACKLIT DISPLAY WHEN ANY KEY IS IN USE.• THREE “AA” EVEREADY ALKALINE BATTERIES INCLUDED.• SYSTEM COMPATIBILITY ON 24 VOLT SYSTEMS INCLUDING SYSTEMS WITH
INTERMITTENT IGNITION CONTROLS OR VENT DAMPERS (NO NEED FOR RELAYS FOR ISOLATING CIRCUITS)
• EMR (ENERGY MANAGEMENT RECOVERY) FOR AN EARLY START TEMPERATURE RECOVERY IN HEATING OR COOLING
• PROGRAMMABLE FAN FEATURE ON HEAT/COOL MODELS• WIDER 40-99° F TEMPERATURE RANGE.• ALSO SUITABLE FOR CENTRAL ELECTRIC HEAT SYSTEMS. NO NEED FOR A
SPECIAL THERMOSTAT MODEL
P/N.: 1F90-0511F97-051
1F90-051 SHOWN
P569
442
WHITE-RODGERS WALL THERMOSTATS
DIGITAL MULTI-STORAGE COMFORT-SET THERMOSTATS
DIGITAL HEAT PUMP COMFORT-SET THERMOSTATS
• SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND• FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS• FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD• AUDIO/VISUAL PROGRAM PROMPTING• LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM
MODES.• “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM.• RED LED SHOWS SYSTEM IS OPERATING (lF91-1)• EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE
OVERRIDE.• BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE).• °F/ °C DISPLAY OPTION.• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING.• COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR
EXTENDED POWER OUTAGES.• BACK-LIT DISPLAY• PROGRAMMABLE BLOWER CONTROL• COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM• OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE).
P/N: 1F91-071
1F91-071 SHOWNP569
• SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND• FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS• FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD• AUDIO/VISUAL PROGRAM PROMPTING• LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM
MODES.• “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM.• EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE
OVERRIDE.• BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE).• °F/°C DISPLAY OPTION.• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING.• COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR
EXTENDED POWER OUTAGES.• BACK-LIT DISPLAY• PROGRAMMABLE BLOWER CONTROL• COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM• OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE).• FOUR LED INDICATOR LIGHTS
EMER (RED) - SYSTEM IN EMERGENCY MODEMALF (RED) - HEAT PUMP SYSTEM MALFUNCTIONINGPUMP (GREEN) - COMPRESSOR OPERATIONAUX (YELLOW) - AUXILIARY HEAT ACTIVITY
P/N: 1F92-071
1F92-071 SHOWN
P573
443
WHITE-RODGERS WALL THERMOSTATS
HEATING/COOLING AND COOLING ONLY ASTRO* STATS WITH SELECTOR-SWITCHES
• DUSTPROOF SEALED MERCURY CELLS OR SNAP-ACTION CONTACTS WITH DUSTCOVER• BEIGE CASE WITH GOLD TONE DIAL• POSITIVE CONTACT SNAP-SWITCHES ON SUBBASE• BIMETAL THERMOMETER• CLEAR FACEPLATE - REMOVABLE FOR EASY CLEANING• HEATING AND COOLING ANTICIPATORS PROVIDE NARROW DIFFERENTIAL CONTROL OF
ROOM TEMPERATURE
P/N: 1D56-3101F56-3011F56-4441E56-444
1D56-301 SHOWN 1F56-444 SHOWN 1E56-444 SHOWN
P574
P574 P574 P577
ASTRO����STATS WITH SNAP ACTION SWITCH
P5781D30-316 SHOWN
• SNAP ACTION CONTACTS WITH DUST COVER• NON-SUSCEPTIBLE TO SLIGHT JARS AND VIBRATIONS• IDEAL FOR MOBILE HOME USE• HEATING AND/OR COOLING ANTICIPATORS PROVIDE A NARROW DIFFERENTIAL CONTROL
OF ROOM TEMPERATURE
P/N: 1D30-3161C30-302
P5771C30-302
444
WHITE-RODGERS WALL THERMOSTATS
AUTOMATIC COMFORT-SET CLOCK THERMOSTATS• ALLOWS INSTALLATION OF SET BACK THERMOSTAT WITHOUT ADDITIONAL WIRING.• SOLID STATE QUARTZ TIMER POWERED BY STANDARD “AA:” ALKALINE BATTERY
ELIMINATES SYSTEM COMPATIBILITY PROBLEMS• BATTERY MAINTAINS CORRECT TIME IN EVENT OF POWER INTERRUPTION• COLOR-CODES, SNAP ON INDICATORS MAY BE POSITIONED TO RAISE OR LOWER
TEMPERATURE FOR ONE OR MORE PERIODS OF TIME FOR INTERVALS AS SHORT AS TWO HOURS
• EQUIPPED WITH ADJUSTABLE HEAT ANTICIPATOR FOR NARROW DIFFERENTIAL CONTROL OF ROOM TEMPERATURE. ANTICIPATOR IS FIELD REPLACEABLE
• SNAP-ON COVER HAS CLEAR, REMOVABLE FACEPLATE FOR CLEANING.
P/N: 1F72-360
1F76-357
1F72-360 SHOWN
1F76-357 SHOWN
P580
P581
P582
HEAT PUMP THERMOSTAT
BASIC MODEL1F78-144 Non-Programmable
STANDARD SERIES
1F80-261 Programmable 5/2 Day
1F86-244 Non-Programmable
P583
• MANUAL CHANGEOVER • DUAL MERCURY CELL ARRANGEMENT ON A SINGLE BI-METAL PROVIDES CONTROL
WITHOUT COMPLICATED GEAR AND LEVER ARRANGEMENTS• THERMOSTAT MOUNTS TO SUBBASE WITH POSITIVE CAPTIVE SCREWS• SUBBASE TERMINAL SCREWS SPACED AND IDENTIFIED FOR EASY INSTALLATION
P/N: 1F58-058
• SELECTABLE ENERGY MANAGEMENT RECOVERY• B & O TERMINALS• 60% LARGER DISPLAY• 4 TIME AND 4 TEMPERATURE SETTINGS (HEAT & COOL)
P4275
445
FAP WALL THERMOSTATS
STANDARD WALL THERMOSTATS (ROBERTSHAW AND WHITE-RODGERS)STANDARD SERIES
THERMOSTAT
• SINGLE STAGE - FOR HEATING OR COOLING ONLY WITHOUT SUB-BASE
• CONVERTS TO HEATING/COOLING WITH SUB-BASE BELOW• SNAP ACTING SPDT SWITCH• HEAT ANTICIPATOR: .18-1.0 AMP ADJUSTABLE• COOLING ANTICIPATOR: FIXED• MOUNTS DIRECTLY ON WALL
SUB-BASE
• MANUAL CHANGEOVER• SYSTEM SWITCH: HEAT-OFF-COOL• FAN SWITCH: ON-AUTO
FOR USE ON:
P/N LOGOHH01YA092 CARRIER
CM-260 ROBERTSHAW
P/NGENERAL
USE
AUTOFAN
OPERATIONUSE ON
SB-4A-12
GAS ELECTRIC SPLIT SYSTEMS
AND SELF-CONTAINED
COOLINGONLY
ONE OR TWO TRANSFORMER
SYSTEMS
HH93YZ094
HEAT PUMP,COOLING WITH
ACCESSORY ELECTRIC HEAT
HEATINGAND
COOLING
SINGLETRANSFORMER
SYSTEMSONLY
P585
24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASE
SINGLE STAGE
THERMOSTAT
• FOR HEATING ONLY WITHOUT SUB-BASE• CONVERTS TO SINGLE STAGE HEATING AND COOLING WITH
SUB-BASE BELOW• SNAP ACTION BI-METAL SWITCH• HEATING ANTICIPATOR: .18-1.0 AMP• INCLUDES CONCEALED WALL PLATE AND TWO MOUNTING
SCREWS
SUB-BASES
• MANUAL CHANGEOVER FOR THERMOSTAT• SYSTEM SWITCH: COOL-OFF-HEAT• FAN SWITCH: ON-AUTO• COOLING ANTICIPATOR: FIXED
FOR USE ON:
P/N: HH01PD042
P/NGENERAL
USE
AUTOFAN
OPERATION
EXTRA TERMINAL
PROVIDED ONHEATING SIDE
USE ON
HH93PZ094
SPLIT SYSTEMS,SELF-CONTAINED
ANDGAS ELECTRIC
COOLINGONLY
ONE OR TWO TRANSFORMER
SYSTEMS
HH93PZ096COOLING WITH
ACCESSORY ELECTRIC HEAT
COOLINGAND
HEATING
P586
446
FAP WALL THERMOSTATS
WALL THERMOSTATS (HONEYWELL)LINE VOLTAGE THERMOSTAT
THERMOSTAT P/N: T651A2028
• SNAP ACTING SPDT DUAL BI-METAL SWITCH• HEATING - CONTACTS OPEN ON TEMP. RISE• COOLING - CONTACTS CLOSE ON TEMP. RISE• FOR HEATING, COOLING AND HEAT/COOL SYSTEMS• CONTROLS FAN COILS, FANS, MOTOR STARTERS, VALVES,
CONTACTORS AND CIRCULATOR MOTORS• FIXED COOLING ANTICIPATOR• MOUNTS ON STANDARD VERTICAL OUTLET BOX• ELECTRICAL RATING (A/C AMPS)
SUB-BASE
• PROVIDES MANUAL SYSTEM SWITCHING• SWITCH POSITIONS: HEAT-OFF-COOL• MOUNTS ON STANDARD VERTICAL OUTLET BOX
WITH HONEYWELL LOGO
WITH CARRIER LOGO
P/N: Q473A2006
20V 208/240V 277VFULL LOAD 8.0 4.0 4.0LOCKED ROTOR 48.0 24.0 4.0RESISTIVE RATING: 7.2 AMPPILOT DUTY RATING: 125VA
7-DAY PROGRAMMABLE THERMOSTAT
• 2 STAGE HEAT AND 2 STAGE COOL • TIME OF DAY DISPLAY • ROOM TEMPERATURE DISPLAY • PROVIDES COMPLETE AUTOMATIC HIGH AND LOW
TEMPERATURE CONTROL • 7 DAY PROGRAMMING • 4 HEAT AND 4 COOL TEMPERATURE SELECTIONS PER DAY • AUTO-CHANGEOVER • INCLUDES SUBBASE AND BATTERIES
P/N: HH641103 WITH CARRIER LOGO
P584
P589
447
MISCELLANEOUS WALL THERMOSTATS
RESIDENTIAL - HEATING - HEATING/COOLING
SUBBASES
HEAT PUMP
LOGOVENDOR &
VENDOR P/NFUNCTION
TEMPRANGE (°F)
HEAT ANTIC.AMPS
NOTES P/N
RobertshawRobertshaw
CM 65Heating-Cooling
50 - 90 0.18 to 1.0Add Subbase SB-6A-12 for switching(Magnetic Contacts)
CM-65
Bryant, Day &Night, Payne
W/RIF56-427
Heating-Cooling
50 - 90 0.15 to 1.2Includes subbase isolated “G” circuit (Mercury Switch)
HH642501
Bryant, Day &Night, Payne
W/RID56-340
Heating-Cooling
50 - 90 0.15 to 1.2Includes subbase isolated “G” circuit(Magnetic Contacts)
HH642502
VENDOR &VENDOR P/N
FANFUNCTION
SWITCH NOTES P/N
RobertshawSB-6A-12
Heating-Off-Cooling Auto-On Use with Thermostat CM-65 SB-6A-12
LOGOVENDOR &
VENDOR P/NFUNCTION
TEMPRANGE
(°F)
HEAT ANTIC.AMPS
NOTES P/N
Bryant, Day &Night, Payne
GE3AAT83Dl4Cl
Normal-EM-HeatingHeating-Auto-Cooling
50 - 900.15 to 0.70
Heat pumpAutomatic changeover
HH643503
Bryant, Day &Night, Payne
GE3AAT83D20Hl
Auto-Heating-Cooling-Off
50 - 900.15 to 0.70
Heat pumpAutomatic changeover
HH07QW002
Bryant, Day &Night, Payne
GE3AAT83D20Bl
Heating-Off-Cooling 50 - 900.15 to 0.70
Heat pumpManual changeover
HH07QW001
Bryant, Day &Night, Payne
M/HY594G-1245
Off-EM Ht-Hi-Auto-Cool
0 to 1.0.1 to 1.2
Heat pumpAutomatic changeover
HH641502
448
ROOM AIR CONDITIONER THERMOSTATS
ROOM AIR CONDITIONER THERMOSTATS
*Bulb length included**Contact Rating FLA @120/240 V
***Thermostats have overtravel at each end of rotation and there is no control in overtravel area.
†Has compressor lockout feature at tend of warm rotation.
OPER.RANGE
(F)
CAP*LENGTH
(in.)
CONTACT ROT.SEEFIG.#
SHAFTLENGTH
(in.)P/N
ARR. FLA**
KNOB TYPE61-89 34 SPDT 20 1 .8 HH22UD06361-89 40 SPDT 20 8 1.1 HH22UC06461-89 18 SPDT 25 2 .9 HH22AD06161-89 18 SPDT 25 7 .6 51DV66000265-92 24 SPDT 25 3 .9 HH22QD06461-91 34 SPDT 30 4 1.0 51HK66001161-90 21 SPDT 20 9 .8 51QF660002†61-89 28 SPDT 20 10 .6 HH22LB065
LEVER ACTUATED***61-92 24 SPDT 25 5 - HH22GD06167-87 18 SPDT 25 6 - 51SW66000467-87 27 SPDT 25 5 - HH22QD067
• BULB TYPE, CROSS- AMBIENT CHARGE
• USED WITH THERMOTUBE
• 51RQ500041• ROTATION DIAGRAMS
APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE
P597
SHAFT SHOWN IN WARM POSITION
W
C W
C W
CW C
W
C W
C
W
C WC
W
CW
C
#1 #2 #3 #4
#5 #6 #7 #8
#9 #10
*Bulb Length included.**Contact Rating FLA @120/240 V
***Thermostats have overtravel at each end of rotation and there is no control in overtravel area.
OPER.RANGE
(F)
CAP*LENGTH
(in.)
CONTACT ROT.SEEFIG.#
SHAFTLENGTH
(in.)P/N
ARR. FLA**
KNOB TYPE25-63 36 SPDT 20 5 .6 HH22UC06759-92 18 SPST 20 1 .5 51KR68005861-83 18 SPST 20 2 .5 51KY13095661-89 18 SPST 20 11 1.9 HH22YB06361-90 18 SPDT 25 3 .6 51PC68009061-90 18 SPDT 25 4 .5 51PH12925661-90 22 SPST 20 6 .9 51EH66000361-90 24 SPST 23 4 .9 HH22GB06266-89 12 SPST 20 8 .6 HH22QB06260-85 24 SPST 25 10 .8 51NT42302007
LEVER ACTUATED***61-90 24 SPST 23 9 - HH22GB06065-91 24 SPDT 25 9 - HH22QD06665-91 36 SPST 30 9 - 51YC660007
• CAPILLARY TYPE, VAPOR CHARGE
• USED WITH THERMOTUBE
• 51RA500131• ROTATION DIAGRAMS
APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE
P598
SHAFT SHOWN IN WARM POSITION
W
C
#3
#6 #8
W C#1
W
C
#2W
CW
C
#4
WC
W
C#10
W
C#11
#5
WC
W
C
#9
449
ROOM AIR CONDITIONER THERMOSTATS
CAC COMPONENTSBELLOWS HEATER
TEMPERATURE SWITCH... SNAP ACTION
VOLTS HEATER RATING (WATTS) P/N115 2.8 51PG098642230 2.7 51PG098517
• BELLOWS HEATERS FOR GENERAL ELECTRIC RAC THERMOSTATS
• USED ON UNITS WHERE A COLD CONTROL BOX CAUSES THERMOSTAT TO CONTROL POORLY
• 5 INCH LEADS• HEATERS MOUNT WITH 51PG098675
CLIP• LEADS TERMINATE IN.25 DOUBLE
QUICK -CONNECTS
P597
• OPENS ON TEMPERATURE RISE
• DISC TYPE
• AUTOMATIC RESET
• SPST CONTACT ARRANGEMENT
• QUICK CONNECT TERMINALS
• 125 VA PILOT DUTYP598
*ENC. - Enclosed bimetal; EX. - Exposed bimetal**Manual reset†1DPST contact arrangement.
Flush mount.
OPEN TEMP.(°F)
CLOSE TEMP.(°F)
FLA 120 VAC FLA 240 VACINSERT DEPTH
(in.)HOLE SIZE
(in.)BIMETAL P/N
40 32 13 10 3/8 1-3/16 ENC. HH17JB03250 40 23 23 3/8 15/16 ENC. HH18HA05070 60 5.8 2.9 3/16 5/8 ENC. HH18HA074
110 85 13 10 3/8 1-3/16 ENC. HH13HA210110 90 10 5 3/8 15/16 EXP. HH18HA110115 85 10 5 11/32 15/16 EXP. HH12HV115†115 90 10 5 3/8 15/16 EXP. HH18HA117120 90 10 5 3/8 15/16 EXP. HH18HA120125 90 10 5 3/8 15/16 EXP. HH18HA125130 90 10 5 3/8 15/16 ENC. HH18HA127130 100 10 5 3/8 15/16 EXP. HH18HA130140 100 10 5 3/8 15/16 EXP. HH18HA141150 110 10 5 3/8 15/16 EXP. HH18HA150150 130 10 5 3/8 15/16 EXP. HH18HA129160 105 4.4 2.2 3/8 15/16 EXP. HH12HA163**160 110 10 5 3/8 15/16 EXP. HH18HA161160 110 13 10 3/8 1-3/16 ENC. HH12HA159160 120 10 5 3/8 15/16 EXP. HH18HA160160 145 4.4 2.2 3/16 13/16 ENC. HH12HA161165 120 4.4 2.2 5/32 13/16 EXP. HH12HA120170 110 10 5 3/8 15/16 EXP. HH18HA173175 120 10 5 3/8 15/16 EXP. HH18HA176180 140 10 5 3/8 15/16 EXP. HH18HA182180 140 10 5 3/8 15/16 ENC. HH18HA194**180 160 10 5 3/8 15/16 EXP. HH18HA179185 145 10 5 3/8 15/16 EXP. HH18HA186185 145 4.4 2.2 3/16 13/16 EXP. HH12HA185190 150 10 5 3/8 15/16 EXP. HH18HA191195 155 10 5 3/8 15/16 ENC. HH18HA195**200 160 7.2 3.6 13/32 1-7/32 EXP. HH12HA199200 135 10 5 ENC. HH18HA199**215 175 10 5 25/64 15/16 ENC. HH18HA215**220 175 10 5 5/32 13/16 EXP. HH12HA225275 230 7.2 3.6 5/32 13/16 EXP. HH12HA275290 250 10 5 25/64 15/16 ENC. HH18HA291**325 280 7.2 3.6 3/16 13/16 EXP. HH12HA325350 280 10 5 25/64 15/16 ENC. HH18HA350**
450
MISCELLANEOUS PARTSMISCELLANEOUS PARTSROOM AIR CONDITIONER SERVICE CORDS
ROOM AIR CONDITIONER FILTERThe 51YA680001 polyure-thane foam replacement room air conditioner filter measures 22-3/4 in. x14-1/2 in. x 1/4 in. thick. It can be trimmed to fit most RAC’s in use today. P/N: 51YA680001
FIGUREWIREGAGE
AMPS VOLTSLENGTH
(in.)P/N
E14
20 25066 52BQ400434
12 92 51SW400063
G10
30 25060 51FL401524
10 100 51YA40059312 66 52BO400444
• 1/4 IN. QUICK CONNECT TERMINALS ON POWER LEADS
• RING TERMINAL ON GROUND WIRE
• IVORY COLOR EXCEPT 51PC CORDS ARE GRAY
FIGUREWIRE
GAUGEAMPS VOLTS
LENGTH(in.)
P/N
A 14 15 125 93 51SA400353
B14
15 25066 52BQ400424
16 113 60AA400084
D12
20 12560 51FA402483
12 113 60AA400094
FIG. A FIG. B FIG. C FIG. D FIG. E FIG. F FIG. GP402
P729
451
TOTALINE® THERMOSTAT GUARDSTHERMOSTAT GUARDS
• Metal: beige
• Plastic: beige or clear
• Sizes fit most thermostats
• Solid and ring bases
• Have key lock
• Virtually tamper proof
Metal
Plastic
P593
P594
Metal
Plastic
WIDTH (in.) HEIGHT (in.) DEPTH (in.) BASE STYLE P/N3-7/8 3-1/2 2-1/2 Solid Beige P269-00105-1/4 4-5/8 3 Solid Beige P269-00115-1/4 4-5/8 3-1/4 Ring Beige P269-00126-3/8 3-1/2 3 Solid Beige P269-00136-3/8 3-1/2 3-1/4 Ring Beige P269-0014
6 3-3/16 3-1/8 Ring Beige P269-00156-1/4 4-3/4 3 Solid Beige P269-00167-1/4 5-3/8 3-1/2 Solid Beige P269-00176-3/4 4-1/4 3-9/16 Ring Beige P269-0018
WIDTH (in.) HEIGTH (in.) DEPTH (in.) BASE STYLE P/N3-7/8 3-1/2 2-1/2 Solid--- Clear- P269-00013-7/8 3-1/2 2-1/2 Solid Beige P269-00025-1/4 4-5/8 3 Solid Clear
P269-00035-1/4 4-5/8 3-1/4 Ring Clear5-1/4 4-5/8 3 Solid Beige
P269-00045-1/4 4-5/8 3-1/4 Ring Beige6-3/8 3-1/2 3 Solid Clear
P269-00056-3/8 3-1/2 3-1/4 Ring Clear6-3/8 3-1/2 3 Solid Beige
P269-00066-3/8 3-1/2 3-1/4 Ring Beige8-1/4 5-3/8 3-1/2 Ring Clear P269-00078-1/4 5-3/8 3-1/2 Ring Beige P269-0008
®
452
SWITCHESROCKER SWITCHES
ROTARY SWITCHES
DESCRIPTION FIGURE P/NOn-Off Action, SPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects, Indicator Light A HR51680001
On-On Action, SPDT Contacts, 20 Amps @ 125 V/250 V, 1-1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects
B
51KX680007
On-Off-Momentary On Action, SPDT Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V 1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects
HR54ZZ001
On-Off Action, DPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 250 V, 1/4 In. Quick Connects
HR54AF042
On-On Action, DPDT Contacts, 10 Amps @ 125 V, 5 Amps @ 250 V,1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects
HR54ZJ001
On-Off Action, SPDT Contacts, 12 Amps @ 125 VAC, 6 Amps @ 250 VAC 3/16 In. Quick Connects
HR54ZD001
On-Off Action, SPST Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V,1/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects C HR51ZA130
Lighted, On-Off Action, SPST Contacts, 16 Amps @ 125 V, 20 Amps @ 250 V, 1/4 In. Quick Connects D (125 V) -
(250 V) -HR54ZA001HR54ZA002
FIG. E FIG. F FIG. GP684
P683P685
DESCRIPTION FIGURE P/NOn-Off Action, SPST Contact, 6 Amps @ 125 V, 3 Amps @ 250 V,1/4 In. Quick Connects E HR56BZ030
On-On Action, SPDT Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/10 HP Rating @ 125 V, 1/4 HP Rating @ 250 V, .25 Shaft, Push In Connections F HR56KH277
On-On Action, SPDT Contacts, 20 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects
G
HR56KE044
Off-1 On-1 & 2 On Action, 35 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @250 V, .25 Shaft, Screw Connections
HR56WL001
Off-1 On-1 & 2 On-2 & 3 On Action, 20 Amps @ 125/250 V, 1-1/4 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects
HR56ZZ010
FIG. A FIG. B FIG. C FIG. DP679
P682P680 P681
453
SWITCHESPUSH BUTTON SWITCHES
TOGGLE SWITCHES
DESCRIPTION FIGURE P/NLighted, normally Off-Momentary On Action, SPST Contacts, 8.5 Amps @ 125 V,1/4 In. Quick Connects, Indicator Light A
HR54ZA020
Lighted, On-Off Action, DPST Contacts, One Pole N.O. and One Pole N.C.,1/4 In. Quick Connects
HR52ZD040
On-Off Action, SPST Contacts, 3 Amps @ 125 V, 1 Amp @ 250 V, Solder Terminals
B
41CA680147Normally Off-Momentary On Action, SPST Contacts, 3 Amps @ 125 V,1 Amp @ 250 V, Leads
HR54BV001
Normally On-Momentary Off Action, SPST Contacts, 6 Amps @ 125 V,3 Amps @ 250 V, 1/4 In. Quick Connects
HR54BV010
Normally On-Momentary Off Action, SPST Contacts, 10 Amps @ 125/250 V,Screw Connections C HR54KX030
On-Off Action, TPST Contacts, 10 Amps @ 125/250 V, Screw Connections HR54KY030On-Off Action, DPST Contacts, 16 Amps @ 125 V, 8 Amps @ 250 V,Screw Connections D HR54BC040
On-Off Action, SPST Contacts, 20 Amps @ 125 V, 10 Amps @ 250 V,3/4 HP Rating @ 125 V/250 V, 1/4 In. Quick Connects (Door Switch) E HR54ZA003
FIG. A FIG. B FIG. C FIG. D FIG. E
P686
P689P687 P688
P690
# (M) stands for momentary.*Rated 30A, 2HP @ 480V.
FIGURE ACTION #CONTACT
ARRANGE- MENT
CONTACT RATINGTERMINAL
CONN.P/NAMPS HP
125V 250V 125V 250V
F
ON-OFF SPST 15 10 1/2 3/4 1/4″ Q.C. HR53ZA035ON-ON SPDT 6 3 1/4 1/4 LEADS HR53ZE050ON-ON SPDT 6 3 1/4 1/4 1/4″ Q.C. HR53AE070ON-ON SPDT 15 10 3/4 3/4 SCREW HR53BE019ON-ON SPDT 15 15 1/2 1 SOLDER HR53ME040
ON-OFF-ON SPDT 15 7.5 1/2 - SCREW HR53VR026ON-(M)ON SPDT 15 10 3/4 3/4 3/16″ Q.C. HR53ZE010
(M)ON-OFF-(M)ON SPDT 6 3 - - 1/4″ Q.C. HR53ED010ON-OFF DPST 15 10 3/4 3/4 SCREW HR53SF015ON-ON DPDT 15 15 1/2 1 SOLDER HR53MJ010ON-ON DPDT 15 10 3/4 3/4 1/4″ Q.C. HR53VK121
ON-OFF-ON DPDT 15 10 3/4 3/4 1/4″ Q.C. HR53VK120ON-OFF-ON DPDT 20 MA - - - 1/4″ Q.C. HR53ZK001
H ON-OFF DPST - x5 - 2 SCREW HR53KA040*
P691FIG. F
P692FIG. H
454
SWITCHESMICRO SWITCHES
*Miniature type.**Used in H-W S952 step controller.†Used in H-W S984 step controller.
FIG.OPER. FORCE
(OZ.)
RELEASE FORCE (OZ.)
CON- TACT ARR.
ELECTRICAL RATING
P/N
A 6-14 4 SPDT10A @
125/250VHR54MA010 *
B 8 2 SPDT5A @ 24V
7A 120/240VHR54MA020 *
C 2.5 .5 SPDT
30A @ 125-460V
HR64TE0403/4 HP @
120V1-1/2 HP @
240V
D 5 1 SPDT10A @ 125V
HR64TE0101 HP @ 125V **2 HP @ 250V
E 6 1 SPDT15A @
125-460VHR64TE038
F 35 8 SPDT 570 VA HR64TE020
FIG. A FIG. B
FIG. C FIG. D
FIG. EFIG. F
P694
P695
P696
P698
P699
P697
MISCELLANEOUS SWITCHES
INDICATOR LIGHTS
• FURNACE DOOR INTERLOCK SWITCH
• SPST-NORMALLY OPEN• 16 AMPS @ 125/250 V
• 10 AMPS @ 125/250 V
P/N: 58SGB4310407
P/N: HR54ZA101P701
P700
• SLIDE ACTION ON-OFF(SPST) SWITCH
• RATED 6 AMPS @ 125 V3 AMPS @ 125V
• 6 IN. LEADS
P/N: 51TJ660012
FIG. VOLTAGELENS
COLORHOLE
SIZE (IN.)TERM.CONN.
P/N
G
24 RED 1/2 3/16″ Q.C HY19AZ02524 AMBER 1/2 3/16″ Q.C HY19AZ024120 RED 1/2 3/16″ Q.C HY19AZ002120 AMBER 1/2 3/16″ Q.C HY19AZ004240 RED 1/2 3/16″ Q.C HY19AZ007240 AMBER 1/2 3/16″ Q.C HY19AZ009
H115 RED 1 1/4″ Q.C HY19UC018230 RED 1 1/4″ Q.C HY19UC014
I24 RED 1/2 3/16″ Q.C 41CA68014324 GREEN 1/2 3/16″ Q.C 41CA68014424 AMBER 1/2 3/16″ Q.C 41CA680145
J 12 WHITE, 1/2 LEADS 31TC113750
FIG. GFIG. H
FIG. I
FIG. J
P702
P703
P704P705
455
TEMPERATURE ACTUATED SWITCHESTEMPERATURE SWITCH... SNAP ACTION
TEMPERATURE SWITCH... SNAP ACTION, FLUSH MOUNT
• SPDT SWITCHING• 1-9/16 IN. MOUNTING HOLE
SPACING• AUTO RESET
*FLA 14 @ 120 VAC and 240 VAC.**Enclosed Disk.
OPEN TEMP (°F) CLOSE TEMP (°F) P/N
100 85 HH19ZA100120 90 HH19ZA120125 90 HH19ZA125130 95 HH19ZA130135 95 HH19ZA135140 100 HH19ZA140145 105 HH19ZA145150 110 HH19ZA150155 105 HH19ZA156155 115 HH19ZA155165 125 HH19ZA165170 130 HH19ZA170175 135 HH19ZA175175 - HH19ZH175*180 130 HH19ZA181180 140 HH19ZA180190 150 HH19ZA190195 155 HH19ZA195195 - HH19ZH195*200 130 HH19ZA201220 - HH19ZA220165 150 HH680302195 155 HH680305205 165 HH680306210 170 HH680307**200 160 HH680311330 250 HH680313**340 300 HH680315
TEMP (°F) AMP.RTG.@ 240 V
INSERTDEPTH
(in.)
HOLESIZE(in.)
P/N1-3OPEN
1-3CLOSE FLA RES.
61 75 2.9 5 3/8 1-1/16 HH18HD07580 65 2.9 5 7/16 1-1/16 HH18HD07095 87 2.9 5 7/16 1-1/16 HH18HD117
105 97 2.9 5 7/16 1-1/16 HH18HD105118 110 2.9 5 7/16 1-1/16 HH18HD118110 90 5 25 3/8 15/16 HH18HV110120 90 5 25 3/8 15/16 HH18HV120125 95 5 25 3/8 15/16 HH18HV125135 110 5 25 3/8 15/16 HH18HV135145 115 5 25 3/8 15/16 HH18HV145155 125 5 25 3/8 15/16 HH18HV155160 130 5 25 3/8 15/16 HH18HV160170 130 3.6 25 3/8 1-7/32 HH12HC171170 140 5 25 3/8 15/16 HH18HV170180 140 2.9 25 5/32 13/16 HH12JC180185 155 5 25 3/8 15/16 HH18HV185205 175 5 25 3/8 15/16 HH18HV205230 190 3.6 25 5/32 13/16 HH12HC230
• SPST• INSERT DEPTH: 3/8 IN.• OPENS ON TEMPERATURE
RISE• FLA: 10 @ 120 VAC
5 @ 230 VAC• HOLE SIZE: 15/16 IN.• HEIGHT MOUNTED:
11/16 IN. P613
P612
• CLOSES ON TEMPERATURE RISE
• SPST. CONTACT ARRANGEMENT
• DISC TYPE• AUTOMATIC RESET
• SPST. CONTACT ARRANGEMENT
• SWITCH RATING: 25 AMPS NON-INDUCTIVE, 25 VA PILOT DUTY @ 120-277 VAC
*Flush mount over hole specified.**Flush mount on surface.
TEMP (°F) FLA120VAC
FLA240VAC
INSERTDEPTH
(in.)
HOLESIZE(in.)
P/NOPEN CLOSE
95 125 13 10 * 1-1/32 HH12HC009*110 135 1 1 ** - HH17JA110**116 175 10 5 3/8 15/16 HH19ZB175190 210 7.2 3.6 7/16 1-7/32 HH12HB210
*SPDT contact arrangement.
TEMP (°F)RESET
CAPIL. LENGTH
(in.)
ELEC.CONN.
P/NOPEN CLOSE
160 140 AUTO. 24 QC HH22HA141190 150 AUTO. 48 QC HH22HA191225 185 AUTO. 48 QC HH22HA225225 185 MAN. 30 QC HH22HA231*240 200 AUTO. 66 SCREW HH22HA240
285 245 AUTO. 96 QC HH22HA284
P613P615
456
TEMPERATURE ACTUATED SWITCHESTEMPERATURE SWITCH ... FLUSH MOUNT
TEMPERATURE SWITCH ... TUBE MOUNTED
• FLUSH SWITCH SURFACE
• SNAP ACTION
• SEALED CONTACTS
• WITH LEADS
• FLUSH SWITCH SURFACE
• SNAP ACTION
• EXPOSED BIMETAL DISC
*Non-inductive rating.**Clip mounted.
***Contacts rated for electromechanical & electronic defrost control.†Contacts make on temperature rise.
TEMP (°F)CONTACT RTG.
(FLA) @CON-TACTARR
LEADLENGTH
(in.)P/N
OPEN CLOSE 120 V 240 V
40 52 *** *** SPST 36 HH18HB04045 35 25* 25* SPST 20 HH22HB07855 65 10 5 SPST 60 HH22HB075†60 70 10 5 SPST 60 HH22HB076†
65 28 6 3.6 SPST 48 HH18JA06670 80 10 5 SPST 60 HH22HB077†80 65 5.8 2.9 SPST 45 HH18HA080S90 120 6 3.6 SPST 48 HH18JB086**†85 65 5.8 2.9 SPDT 27 HH18HC071
105 43 6 3.6 SPST 36 HH18JA105115 100 *** *** SPST 36 HH18HA116278 178 13 10 SPST 30 HH18HB278290 210 25* 25* SPST 72 HH18HA210
†Contacts make on temperature rise.
TEMP (°F)CONTACT RTG.
(FLA) @CON-TACTARR.
ELEC.CONN.
P/NOPEN CLOSE 120 V 240 V
45 35 10 5 SPST QC HH22HB07847 57 10 5 SPST QC HH18HB052†
130 100 - 35 SPST SCREW HH18HA132140 110 - 35 SPST SCREW HHI8HA139150 110 10 5 SPST QC HHI8HA149
150 110 - 35 SPST SCREW HH18HA152155 110 - 35 SPST SCREW HH18HA155175 120 - 35 SPST SCREW HH18HA178190 140 - 35 SPST SCREW HH18HA192140 125 - - SPST HH680101
170 130 - - SPST HH680102160 145 - - SPST HH680103190 150 - - SPST HH680104
P616P618
*Clip mounted.**Contacts rated for electromechanical & electronic defrost control.†Contacts make on temperature rise.‡Used on aluminum tube.
TUBEDIA.(in.)
TEMP (°F)CONTACTRTG. (FLA) CON-
TACTARR.
LEADLENGTH
(in.)P/N
@120 V
@240 V
OR CL.
5/8 5 45 125VA 125VA SPST QC HH18JA005t†5/8 28 48 13 10 SPST 43 HH18HA028†5/8 65 35 5.8 2.9 SPST 48 HH18HA0595/8 65 45 5.8 2.9 SPST 36 HH18HA0695/8 85 65 5.8 2.9 SPDT 63 HH19HC263*5/8 85 65 5.8 2.9 SPDT 18 HH18HA0855/8 1265 1651 13 10 SPST 36 HH18HA265
TUBE DIA.(in.)
TEMP (°F))CONTACT RTG. (FLA) CON-
TACTARR.
LEADLENGTH
(in.)P/N
@120 V
@240 V
OP. CL.
3/8 25 53 5.8 2.9 SPDT 36 HH18HC025†3/8 30 45 5.8 2.9 SPST 48 HH18HB0303/8 65 35 13 10 SPST 48 HH18HA0363/8 80 27 * * * * SPST 95 HH18HA0943/8 80 27 * * * * SPST 95 HH18HA098‡
3/8 80 40 * * * * SPST 48 HH18HH0913/8 85 65 5.8 2.9 SPST 45 HH18HA0863/8 90 80 5.8 2.9 SPST 35 HH18HA0803/8 100 135 5.8 2.9 SPST 24 HH18HA100†3/8 140 125 5.8 2.9 SPST 24 HH18HA142
3/8 50 27 * * * * SPST QC HH18HA0811/2 5 45 125VA 125VA SPST QC HH18JA004†1/2 25 53 5.8 2.9 SPDT 102 HH18HC102†1/2 60 40 5.8 2.9 SPST 75 HH18HA0471/2 61 35 6 3.6 SPST 36 HH18JA062
1/2 65 28 6 3.6 SPST 48 HH18JA0671/2 65 35 13 10 SPST 36 HH18HA0351/2 65 45 5.8 2.9 SPDT 36 HH18HC0651/2 80 27 * * * * SPST 55 HH18HA095‡1/2 85 65 1.5 1.5 SPST 19 HH18HA054
• TUBE MOUNTED
• SNAP ACTION
• SEALED CONTACTSP617
457
TEMPERATURE ACTUATED SWITCHESNON-ADJUSTABLE TEMPERATURE ACTUATED SWITCHES
ADJUSTABLE REMOTE BULB THERMOSTATS
• FIXED DIFFERENTIAL
• VAPOR FILLED
• CONTACTS RATED 20 FLA @ 240 VOLTS
• REMOTE BULB NON-ADJUSTABLE THERMOSTAT
• SPST CONTACTS OPEN ON TEMPERATURE RISE
CONTACTS(°F)
CONTACT RTG.(FLA) @
CAPIL.LENGTH
(ft)
BULBSIZE(in.)
P/NOPEN CLOSE 120V 240V
275 200 16 8 3 3/8 x 3 HH22YC275
SPDT SWITCHING
CONTACTS (°F)DIFFER-
ENTIAL (°F )
CAPIL. LENGTH
(in.)P/N
OPEN CLOSE
26 55 29 36 50BB66000135 39 4 35 HH22UA035
72.5 67.5 5 18 HH22UA070
TEMP.SETTINGS (°F) DIFFER-ENTIAL
(°F)
CAPIL.LENGTH
(in.)P/N
2-1 MAKE 2-3 MAKE
15 35 20 42 HH22UC03420 45 25 27 HH22UC02036 42 6 24 HH22UC03840 44 4 27 HH22UC04087 91 4 18 HH22UC090
• DPST SWITCHING ACTION WITH ONE SIDE COMMON
• 24 VOLT MAXIMUM AC ROSS TERMINALS
• Tl CONTACTSCLOSE @ 50 ° FT2 CONTACTSCLOSE @ 54 ° F
P/N: HH21PD055
1
2
3
P339-2
P623
P619
*Opens on temperature rise.**Close on temperature rise.
FIGURECAPILLARYLENGTH (ft)
BULB SIZE(in.)
RANGE(°F)
DIFFER-ENTIAL (°F)
CONTACTARR.
CONTACT RATING. (FLA) P/N
@ 120 V @ 240 VB 6 3/8 x 5.5 -20 to 70 6 SPST* - 25 HH22YA070C 10 3/8 x 5 -10 to 55 5 SPST* - 30 HH22VA040D 4 3/8 x 3.7 0 to 50 6 SPST* - 6 HH22PA050G 4 3/8 x 7.2 50 to 70 2 SPDT 20 20 HH22UA078G 3 3/8 x 7 58 to 85 3 SPDT 20 20 HH22UZ101E 2 3/8 x 5 60 to 96 3 SPDT - 20 50BQ580-07
FIG. B FIG. C FIG. D FIG. F
P621P627
P626P624P622
FIG. G
458
TEMPERATURE ACTUATED SWITCHESADJUSTABLE REMOTE BULB THERMOSTATS
• STAGED REMOTE BULB THERMOSTATS• 2, 3 AND 4 -SPDT TYPES AVAILABLE • 140° F MAX. BULB TEMPERATURE• 15 FT CAPILLARY
• TWO STAGE REMOTE BULB THERMOSTATS
• TWO SPST SWITCHES OPEN ON A DROP IN TEMPERATURE
• 7-1/2 FT CAPILLARY• 160° F MAX. BULB TEMPERATURE• CONTACT RATING: 8A @ 120/240 V
• SINGLE STAGE REMOTE BULB THERMOSTATS
• SCREWDRIVER ADJUSTABLE FOR LIMITED ACCESS APPLICATIONS
FIG. A FIG. B FIG. C
*Closes on temperature drop.**See contact arrangement diagram by photo, Figure C.
FIGURERANGE
(°F)
SWITCHDIFFERENTIAL
(°F)
INTERSTAGEDIFFERENTIAL
(°F)
CONTACTARR.
CONTACT RATING.(FLA) @ - BULB SIZE
(in.)
CAPIL.LENGTH
(in.)P/N
@ 120 V @ 240 V
A20 to 8010 to 8010 to 80
3.5 6 2-SPDT 16 8 3/8 x 5.6 - HH24CZ0203 3.5 3-SPDT 10 5 3/8 x 4 - HH24CZ0213 2.5 4-SPDT 10 5 3/8 x 4 - HH24CZ022
B 55 to 105 5 13 - - - 1/2 x 3 - HH29AA080
C-15 to 4525 to 6135 to 62
8 - SPST - 5 - 36 HH22QA040*4 - SPDT - 20 - 30 HH22UC063**4 - SPDT - 20 - 33 HH22UC062*
1
2
3
P629 P630P628
459
TEMPERATURE ACTUATED SWITCHESREMOTE BULB THERMOSTATS
• ACCURATELY REGULATES TEMP. OF AIR OR LIQUIDS IN DUCTS, PIPES OR TANKS WHERE CONTROLLER MUST BE PLACED OUTSIDE THE SENSING AREA
• HH22AN100 AND HH22AL090 ARE TWO STEP CONTROLS. HH22AN100 HAS AN ADJUSTABLE INTERSTAGE DIFFERENTIAL OF 3 TO 10 DEGREES. HH22AL090 HAS A FIXED INTERSTAGE DIFFERENTIAL OF 2-1/2 DEGREES.
• REMOTE BULB TEMPERATURE CONTROLS WITH SPST CONTACTS THAT CLOSE ON TEMPERATURE RISE
• HH22PB030 AND HH22PB036 ARE MANUAL RESET DEVICES
• REMOTE BULB TEMPERATURE CONTROL
• BULB WELL IS SUPPLIED WITH CONTROL
• MAY BE MOUNTED IN ANY POSITION
FIG. FFIG. EFIG. D
*HH22AL090, HH22AC090 do not have an enclosure.
FIGURERANGE
( °F)DIFFER-
ENTIAL ( °F)CONTACT
ARR.CONTACT RATING. (FLA) CAPILLARY
LENGTH (ft)BULB SIZE
(in.)MAX.
TEMP ( °F)P/N
@120 V @240 V
D
-30 to 90 Adj. 5 to 40 SPDT 7.4 3.7 8 3/8 x 5.0 155 HH22PC0200 to 100 Adj. 3 to 10 SPDT 8 5.1 20 1/2 x 4.5 125 HH22AG1060 to 100 Non-Adj.3 2-SPDT 8 5.1 20 1/2 x 4.5 125 HH22AN10055 to 90 Non-Adj. 2 SPDT 3.2 1.6 5 5/16 x 11.7 135 HH22AC090*55 to 90 Non-Adj. 2 2-SPDT 8 5.1 5 1/2 x 11.7 135 HH22AL090*
E-20 to 50 - SPST 7.4 3.7 10 3/8 x 5.7 120 HH22PB03020 to 75 Adj.3 to 20 SPST 13 6.5 8 3/8 x 7.2 120 HH22PB03233 to 55 - SPST 7.4 3.7 20 5/16 x 11 120 HH22PB036
F 50 to 200 Adj. 6 to 24 SPDT 16 8 20 3/8 x 4 290 HH680-608
P631 P632P633
460
TEMPERATURE ACTUATED SWITCHESREMOTE BULB PROPORTIONAL TEMPERATURE CONTROLLER
CONTROL BULB
• PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS
• USED IN 24 VOLT CIRCUIT• AMBIENT COMPENSATED• 135 OHM POTENTIOMETER• HONEYWELL TYPE T991A
• PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS
• USED IN 24 VOLT CIRCUIT• AMBIENT COMPENSATED• 135 OHM POTENTIOMETER• HONEYWELL TYPE T915,
PENN TYPE A80
FIG. A FIG. B
*Control has 76 inch sensing element.
FIGURESET POINT ADJ.
RANGE ( °F)THROTTLINGRANGE (°F)
MAX.BULBTEMP ( °F)
CAPILLARYLENGTH (ft)
SIZE OF BULB(in.)
P/N
A0 to 100 3 to 30 125 20 1/2 x 4 HH23AG0450 to 100 3 to 30 125 9.6 1/2 x 76 HH22AG103*
B10 to 90 7 to 38 130 11 11/16 x 7 HH23AG03015 to 90 7 to 38 200 20 1/2 x 4 HH23AG085
P631
P635
• CONTROL BULB WELLS FOR USE WITH TEMPERATURE CONTROLLERS
• BUSHING INCLUDED
FOR BULBDIA. (in.)
DIMENSIONS (in.) THREADSIZE NPT
P/NA B C D
5/16 13.0 11.5 1.2 .4 1/2-14 HL79PZ0013/8 6.3 5.0 .7 .4 1/2-14 30HH4061023/8 7.6 5.8 1.4 .4 1/2-14 HL79ZZ0021/2 8.7 4.2 3.7 .7 1/2-14 HL79MZ0011/2 8.7 4.2 3.7 .7 3/4-14 HL79MZ0051/2 5.7 4.2 .7 .7 1/2-14 HL79MZ007
A
BCD
461
TEMPERATURE ACTUATED SWITCHESAQUASTAT CONTROLLERS
SWITCHING RELAYS
P4320
P/N P672-L4006
• TOTALLY ENCLOSED MICRO SWITCH SNAP-ACTING SWITCHES OPERATE ON TEMPERATURE RISE TO SET POINT.
• VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING.
• HORIZONTAL OR VERTICAL INSERTION AND DIRECT OR WELL IMMERSION OF SENSING ELEMENT.
P/N P672-L6006C
• OPERATE IN RESPONSE TO TEMPERATURE CHANGES IN HYDRONIC HEATING SYSTEMS.
• PROVIDES SPDT SWITCHING FOR THREE-WIRE APPLICATIONS.
• COMBINES CIRCULATOR CONTROL WITH HIGH AND LOW LIMITS.
• HORIZONTAL OR VERTICAL SURFACE MOUNTING.
• VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING.
P4321
P/N P672-L7124U UNIVERSAL OIL ELECTRONIC AQUASTAT CON-TROLLER
• PROVIDES ELECTRONIC TEMPERATURE SENSING IN A UL LIMIT-RATED CONTROL WITH A SINGLE SENSING PROBE.
• CONTROLS CIRCULATOR, OIL BURNER, AND BOILER TEMPERATURE.• REPLACES THE L8124A, L8124C, L8148A CONTROLLERS.• THE L7124U HAS A CASE THAT CAN BE CONVERTED FOR EITHER
HORIZONTAL OR VERTICAL MOUNTING.
PART NUMBERHONEYWELL
PART NUMBERP672-L4006A L4006A1009P672-L4006B L4006B1007P672-L6006C L6006C1018P672-L7124U L7124U1003
P4325
P/N P673-RA889A SWITCHING RELAY (HYDRONIC)
• HIGH LOAD SWITCHING RELAY.• TROUBLESHOOTING LED.• REPLACEABLE TRANSFORMER FUSE.• LONG LIFE DC RELAY DRIVE CONTROL
TECHNOLOGY.• RELAY FOR USE WITH EXTERNAL 24 VAC
OR 24 VDC SUPPLY, WITH LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER SUPPLY.
P/N P673-R8845A UNIVERSAL SWITCH-ING RELAY (HYDRONIC)
• REPLACEABLE, SOCKETED RELAY.• TWO TROUBLESHOOTING LED’S.• PUSH-TO-TEST BUTTON.• REPLACEABLE TRANSFORMER FUSE.• LOW VOLTAGE CONTACTS FOR POWERPILE
APPLICATIONS.• RELAYS CAN BE USED WITH EXTERNAL
24-VAC OR 24-VDC SUPPLY, LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER.
PART NUMBERHONEYWELL
PART NUMBERP673-RA889A RA889A1001P673-R8845A R8845U1003