METZ CONNECT GmbH Im Tal 2 | 78176 Blumberg | Germany | Phone +49 7702 533-0 | Fax +49 7702 533-433 Mounting instruction see www.metz-connect.com 1. Description The NG4 power supply supplies regulated direct voltages for supplying power to the respective devices of the product family of I/O components. The device supplies regulated direct voltage 24 V DC at a power of 16 watts. A parallel operation of several power supply units is not allowed. The secondary voltage can only be tapped at the right side of the plug connector and at the screw-type terminals on the top of the module. The bus communication is looped through on both sides of the plug connectors. 8038/899243-01 Power Supply NG4 110561-01 3. Technical Data Input Operating voltage 110 - 240 V AC, 50 - 60 Hz Internal fuse T1AL/250 V soldered fuse Output Output voltage DC +24 V (SELV) Output current (max) 700 mA Output power 16 W Load and control accuracy ±3% (Tu = 20 °C) Protection and monitoring Continuous short circuit protection yes Idle test yes Mains failure backup > 40 ms at 230 V AC and full load Dielectric strength 4000 V AC input/output Device security Standard Conformity was proofed. The declaration of conformity is available at the manufacturer BTR NETCOM GmbH. Output Safety Extra Low Voltage (SELV) according EN 60950 Protection class 2 EMV CE conformity Emitted interference/ Immunity to interference the device was tested according to the applicable standards; conformity was proofed, the declaration of conformity is available at BTR NETCOM Contacting Primary and secondary screw type terminal blocks Cover no Type of protection IP20 (nach EN 60529) Wire cross section 1.5 mm 2 Housing Dimensions WxHxD 1.968 x 2.756 x 2.559 in. 50 x 70 x 65 mm) Front dimension 1.772 in. / 45 mm Weight 108 g Mounting position any Mounting standard rail TH35 per IEC 60715 Material Housing Polyamide 6.6 V0 Terminal blocks Polyamide 6.6 V0 Cover plate PolycarbonateB Mounting in series without space Type of protection (IEC 60529) Housing IP40 Terminal blocks IP20 Terminal blocks Wire cross section max. AWG 12 (4.0 mm²) solid wire max. AWG 14 (2.5 mm²) stranded wire Wire diameter min. 0.3 mm up to max 2.7 mm Temperature range Operation -10 °C to +55 °C Storage -25 °C to +85 °C 4. Connection Diagram +24V L N L N Operating voltage 110 - 240 V AC 1 A +24V Output voltage 24 V DC 0,7 A +24V +24V A- B+ L N 5. Wiring Diagram 2. Important Notes Declaration of Conformity The device was tested according to the applicable standards. Confor- mity was proofed. The declaration of conformity is available at the manufacturer BTR NETCOM GmbH. Notes Regarding Device Description These instructions include indications for use and mounting of the device. In case of questions that cannot be answered with these in- structions please consult supplier or manufacturer. The indicated installation directions or rules are applicable to the Federal Republic of Germany. If the device is used in other countries it applies to the equipment installer or the user to meet the national directions. Safety Instructions Keep the applicable directions for industrial safety and prevention of accidents as well as the VDE rules. Technicians and/or installers are informed that they have to electrically discharge themselves as prescribed before installation or maintenance of the devices. Only qualified personnel shall do mounting and installation work with the devices, see section “qualified personnel”. The information of these instructions have to be read and understood by every person using this device. Symbols Warning of dangerous electrical voltage Danger means that non-observance may cause risk of life, grievous bodily harm or heavy material damage. Qualified Personnel Qualified personnel in the sense of these instructions are persons who are well versed in the use and installation of such devices and whose professional qualification meets the requirements of their work. This includes for example: Qualification to connect the device according to the VDE specifications and the local regulations and a qualification to put this device into operation, to power it down or to activate it by respecting the internal directions. Knowledge of safety rules. Knowledge about application and use of the device within the equipment system etc.
Transcript
Page 1: +24V Power SupplyMount the module on standard rail (TH35 per IEC 60715 in junction boxes and/or on distribution panels). Installation Electric installation and device termination shall

METZ CONNECT GmbHIm Tal 2 | 78176 Blumberg | Germany | Phone +49 7702 533-0 | Fax +49 7702 533-433Mounting instruction see www.metz-connect.com

1. DescriptionThe NG4 power supply supplies regulated direct voltages for supplying power to the respective devices of the product family of I/O components. The device supplies regulated direct voltage 24 V DC at a power of 16 watts. A parallel operation of several power supply units is not allowed. The secondary voltage can only be tapped at the right side of the plug connector and at the screw-type terminals on the top of the module. The bus communication is looped through on both sides of the plug connectors.

8038

/899

243-

01

Power SupplyNG4110561-01

3. Technical DataInputOperating voltage 110 - 240 V AC, 50 - 60 Hz Internal fuse T1AL/250 V soldered fuse

OutputOutput voltage DC +24 V (SELV) Output current (max) 700 mA Output power 16 W Load and control accuracy ±3% (Tu = 20 °C)

Protection and monitoringContinuous short circuit protection yesIdle test yesMains failure backup > 40 ms at 230 V AC and full loadDielectric strength 4000 V AC input/output

Device securityStandard Conformity was proofed. The declaration of conformity is available at the manufacturer BTR NETCOM GmbH.Output Safety Extra Low Voltage (SELV) according EN 60950Protection class 2

EMV CE conformityEmitted interference/ Immunity to interference the device was tested according to the applicable standards; conformity was proofed, the declaration of conformity is available at BTR NETCOM

ContactingPrimary and secondary screw type terminal blocks Cover no Type of protection IP20 (nach EN 60529) Wire cross section 1.5 mm2

HousingDimensions WxHxD 1.968 x 2.756 x 2.559 in. 50 x 70 x 65 mm)Front dimension 1.772 in. / 45 mmWeight 108 gMounting position anyMounting standard rail TH35 per IEC 60715Material Housing Polyamide 6.6 V0 Terminal blocks Polyamide 6.6 V0 Cover plate PolycarbonateBMounting in series without space Type of protection (IEC 60529) Housing IP40 Terminal blocks IP20

Terminal blocksWire cross section max. AWG 12 (4.0 mm²) solid wire max. AWG 14 (2.5 mm²) stranded wireWire diameter min. 0.3 mm up to max 2.7 mm

Temperature rangeOperation -10 °C to +55 °C Storage -25 °C to +85 °C

4. Connection Diagram

+24

V

L N

L NOperating voltage110 - 240 V AC1 A+24V Output voltage24 V DC0,7 A

+24

V

+24

V

A- B+

L N

⊥ ⊥ ⊥

5. Wiring Diagram

2. Important NotesDeclaration of Conformity The device was tested according to the applicable standards. Confor-mity was proofed. The declaration of conformity is available at the manufacturer BTR NETCOM GmbH.

Notes Regarding Device DescriptionThese instructions include indications for use and mounting of the device. In case of questions that cannot be answered with these in-structions please consult supplier or manufacturer. The indicated installation directions or rules are applicable to the Federal Republic of Germany. If the device is used in other countries it applies to the equipment installer or the user to meet the national directions.

Safety InstructionsKeep the applicable directions for industrial safety and prevention of accidents as well as the VDE rules. Technicians and/or installers are informed that they have to electrically discharge themselves as prescribed before installation or maintenance of the devices.Only qualified personnel shall do mounting and installation work with the devices, see section “qualified personnel”. The information of these instructions have to be read and understood by every person using this device.

SymbolsWarning of dangerous electrical voltage

Danger means that non-observance may cause risk of life, grievous bodily harm or heavy material damage.

Qualified PersonnelQualified personnel in the sense of these instructions are persons who are well versed in the use and installation of such devices and whose professional qualification meets the requirements of their work. This includes for example: • Qualification to connect the device according to the VDE specifications and the local regulations and a qualification to put this device into operation, to power it down or to activate it by respecting the internal directions. • Knowledge of safety rules. • Knowledge about application and use of the device within the equipment system etc.

Page 2: +24V Power SupplyMount the module on standard rail (TH35 per IEC 60715 in junction boxes and/or on distribution panels). Installation Electric installation and device termination shall

METZ CONNECT GmbHIm Tal 2 | 78176 Blumberg | Germany | Phone +49 7702 533-0 | Fax +49 7702 533-433Mounting instruction see www.metz-connect.com

• The module can be aligned without interspace. Use the jumper plug to connect bus and supply voltage when the modules are mounted in series. • The maximum quantity of modules connected in line is limited to 15 or to a maximum power consumption of 2 Amps (AC or DC) per connection to the power supply. For any similar block of additional modules a separate connection to the power supply is mandatory.

Preparing cable for connection. Strip the wire by 7 mm, attach an end sleeveif necessary, insert the wire into the contact and tighten the terminal screw with a screwdriver.

2

3 4

7 mm

1

6. MountingPower down the equipmentMount the module on standard rail (TH35 per IEC 60715 in junction boxes and/or on distribution panels).InstallationElectric installation and device termination shall be done by qualified persons only, by respecting all applicable specifications and regulations.

+24V

NG4

B+A-

B+A-

24 VGND

L

24V

24V

24V

T T T

L

N

N

A-

B+

24V24V 24V24V 24V24V24V 24V24V 24V

B+B+ B+B+ B+A-A- A-A- A-

B+B+ B+B+ B+A-A- A-A- A-

24 V24 V 24 V24 V 24 VGNDGND GNDGND GND

24 V24 V 24 V24 V 24 VGNDGND GNDGND GND

2+

2+

2+

2+

2+

2-

2-

2-

2-

2-

1+

1+

1+

1+

1+

1-

1-

1-

1-

1-

3+

3+

3+

3+

3+

3-

3-

3-

3-

3-

4+

4+

4+

4+

4+

4-

4-

4-

4-

4-

B+A-

B+A-

24 V24 V

B+B+GNDGNDB+B+

No 24 V DC transmission!

No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!No 24 V DC transmission!

24 V DC output voltage

L / N operating voltage 110-240 V AC

7. Termination possibility

• Connection on the right side of the NG4 for voltage feeding and bus tap to the following bus modules (with jumper connection for example) • Conneciton on the left side of the NG4 transfer of the bus connection by jumper connection. No 24 V DC connection! • Parallel connection of several NG4 devices is not possible.