+ All Categories
Home > Documents > 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing...

2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing...

Date post: 14-Apr-2020
Category:
Upload: others
View: 6 times
Download: 0 times
Share this document with a friend
10
2.9GHz SPECTRUM ANALYZER
Transcript
Page 1: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

2.9GHz SPECTRUM ANALYZER

Page 2: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Introducing a new 2.9GHz Spectrum Analyzer

Field Service

Research and Development Manufacturing Research and Development

Field Service Education

Page 3: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Powerful capacity by advanced digital synthesizer

Page 4: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Revolutionary features of SA-9270A

Page 5: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Versatile functions, simple operation, and convenient portability

Page 6: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Revolutionary test modes of SA-9270A

Page 7: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education
Page 8: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Tuning Range: 9 kHz to 2.9 GHz Tuning Resolution: 1 Hz minimum Frequency Span Width: 100Hz/div to 290 MHz/div

:1,2,5 step selections (auto selected) plus ZEROSpan, and FULL Span (9 kHz to 2.9 GHz). start,stop Span - Manual selections

Span Accuracy: 3% of the indicated Span Width. Readout accuracy Span accuracy+ frequency

Standard accuracy 50% of RBW.Frequency Counter:

Resolution: 1 kHz, 100 Hz, 10 Hz, 1 Hz Accuracy (Reference frequency error + counter resolution +/- 1 count)Sensitivity: -70 dBm (50kHz~2.9 GHz)

Stability:Residual FM: <100 Hzp-p 200ms @ 1 kHz RBW, 1 kHz VBW

(P-P in 20 ms)Noise Sidebands: -90 dBc/Hz @ 10 kHz offset

Measurement range +30dBm to displayed average noise levelAverage Displayed Noise Level: 50 kHz to 100 kHz: -95 dBm

100 kHz to 1 MHz: -105 dBm1 MHz to 2.9 GHz: -110 dBm(1kHz RBW, 10 Hz Video Filter)

1dB Compression Point: -10 dBm 100 kHz to 2.9 GHz (0dB attenuation)Displayed Range: 100 dB in 10 dB/div log scale.

50 dB in 5 dB/div log scale.20 dB in 2 dB/div log scale.10 dB in 1 dB/div log scale.10 divisions with linear amplitude scale.

Amplitude Units :Log Scale Mode : dBmV or dBm units.Linear Scale Mode : V(uV, mV, etc.), or dBV(dBmV only)Quasi Peak Enabled : dBuV, dBmV, or dBm only

Display Linearity : 5 or 10 dB/div, 0.15 dB/dB, 1.5 dB over 10 divisions.1 or 2 dB/div, 0.5 dB over 10 divisions.Linear, 10% of Reference Level over 10 divisions

Frequency Response: -3.0~ +1 dB, 9 kHz to 10 MHz, +/-1.5 dB, 10 MHz to 2.9 GHz(10 dB RF Attenuation)

Attenuator :Range 0 to 50 dB, Selected manually or automatically

coupled to reference level.Resolution 10 dB steps.Accuracy : 0.5 dB/step up to 1.5 dB maximum at 100MHz

Reference Level:Accuracy : +/- 1.5 dB (50 kHz to 2.9 GHz)Range : -110 dBm to +30 dBm with 1k Hz filter using 1dB/div scaleResolution : 0.1 dB Step minimum

Residual Spurious -85 dBm (input terminated, 0 dB attenuation)Harmonic Distortion : -60 dBc, -40 dBm input, 0 dB attenuation.Intermodulation Distortion : -70 dBc, 100MHz to 2.9 GHz, -30 dBm input

(3rd order) 0 dB attenuation -60 dBc, 1MHz to 100MHz, -30 dBm inputOther input related spurious : -60 dBc, 10MHz to 2.9 GHz, -30 dBm inputResolution Bandwidth:

Selections: 300Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz,300 kHz, 1 MHz, 3 MHz

Accuracy : 20%Selectivity: 60 dB/3 dB ratio <15:1

60 dB/6 dB ratio <12:1; 9 kHz & 120 kHz (Quasi Peak Option).

Switching Error: 1.0 dB (3kHz Reference RBW)Video Bandwidth Selection: 10 Hz to 1 MHz in 1-3-10 steps plus None.

Rate: 50 ms to 1000 sec in 1-2-5 sequence,25us to 20 sec (ZERO SPAN)

Sweep rate accuracy : 20%, <100msec10%, for all other sweep rates

Trigger:Source : External (rear), Line, Video, Freerun.Modes : continuous, Single.

External rear level : TTL LevelDelay : +/- one sweep time (zero span)

Page 9: 2.9GHz SPECTRUM ANALYZER · Introducing a new 2.9GHz Spectrum Analyzer Field Service Manufacturing Research and Development Research and Development Field Service Education

Trace storage: Maximum 1,000 stored traces (*. TRC)Setup storage: Maximum 2,000 stored states (*. STS)

DisplayType : 6.4 color TFT LCDDigital resolution : 640 H x 480 V active display areaMarker Modes : peak Search, Peak Track, Delta Marker, 1/Delta

Marker, Marker Track; Marker to Center,Marker to Reference (9 markers maximum)

RF input:Connector: N type Female, 50ohm nominal.VSWR: 150kHz to 2.9 GHz, VSWR<1.5:1. (with 10 dB Input attenuation)Maximum input level : 50 Vdc, +30 dBm (with 40 dB attenuation)LO Emissions -70 dBm (with 10 dB attenuation)

OutputIF output 10.7 MHz, Nominal Video output 0 to 5V DC

STANDARD HIGH STABILITY OptionTemperature stability : 2 ppm 0.1 ppmAging : 1 ppm/year 0.1 ppm/yearConnector : BNC female connector.Input level -5 dBm to + 15 dBmOutput level 10 MHz @ +5 dBm nominal

Conforms to : IEEE-Standards 488.1 -1987. 488.2 - 1992.Implemented subsets : SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, C0, LE0, TE0

Type : 110, 300 bps Baud Rate : 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19.2 kbps ,

38.4 kbps , 57.6 kbps , 115.2 kbps Parity Check : Odd, Even or None, Mark, Space Data Length : 7 bits, 8 bits.Stop Bits : 1 bit, 2 bit.Protocol: None, Xon-Xoff, RTS-CTS, DTR-DSR

Drivers : PCL3 or higherConnection : Standard 25 Pin female D-Sub parallel printer

Power Probe HP 85024A compatiblePower 3 pins (+15V, -12V, GND)

Dimensions: 350 mm : width (including handle)185 mm : height381 mm : depth

Weight: 9.4 KgWarm-up time : 15 minutes for specified accuracyPower requirements (Standards)

Source voltage and frequency : 100-240 VAC at 50/60HzPower consumption : 90 watts maximum (without options)

Fuse requirementF1 and F2100 to 120 VAC 3.15A, 250V, Type T220 to 240 VAC 3.15A, 250V, Type TEnvironmental range

Use IndoorsOperating temperature 0 to 40 .Storage temperature -20 to 70 .Temperature / Humidity : MIL-T-28800E : Type 2, Class 5

( Operating : 85% , Storage : 90% )Vibration / Shock: MIL-T-28800E : Type 2, Class 5Altitude : Operation up to 3,000 meters

Non-operational up to 40,000

Product safety EN61010-1Main supply voltage fluctuations : nominal voltage 10%Transient overvoltage : Installation Category II Pollution degree : 2

RF emissions and immunityRF emissions EN 55011: 1991, Class A RF Immunity EN 50082-1: 1997