SHEET INDEX1 AT ELECTRICAL LAYOUT AND DEVICES2 AT DATA LAYOUT3 CT ELECTRICAL LAYOUT AND DEVICES L3 CLEARSCAN4 CT DATA LAYOUT L3 CLEARSCAN5 CT ELECTRICAL LAYOUT AND DEVICES IDSS DETECT 10006 CT DATA LAYOUT IDSS DETECT 10007 CT ELECTRICAL LAYOUT AND DEVICES ANALOGIC CONNECT8 CT DATA LAYOUT ANALOGIC CONNECT9 CT ELECTRICAL LAYOUT AND DEVICES SMITHS DETECTION HI-SCAN
10 CT DATA LAYOUT SMITHS DETECTION HI-SCAN11 CT ELECTRICAL LAYOUT AND DEVICES SCANTECH SENTINEL III12 CT DATA LAYOUT SCANTECH SENTINEL III13 ASL ELECTRICAL LAYOUT MACDONALD HUMFREY14 ASL ELECTRICAL DEVICES MACDONALD HUMFREY15 ASL DATA LAYOUT MACDONALD HUMFREY STANDALONE16 ASL DATA LAYOUT MACDONALD HUMFREY CENTRALIZED SERVER17 ASL ELECTRICAL LAYOUT VANDERLANDE INDUSTRIES18 ASL ELECTRICAL DEVICES VANDERLANDE INDUSTRIES19 ASL DATA LAYOUT VANDERLANDE INDUSTRIES STANDALONE20 ASL DATA LAYOUT VANDERLANDE INDUSTRIES CENTRALIZED SERVER21 ASL ELECTRICAL LAYOUT SCARABEE SYSTEMS22 ASL ELECTRICAL DEVICES SCARABEE SYSTEMS23 ASL DATA LAYOUT SCARABEE SYSTEMS STANDALONE24 ASL DATA LAYOUT SCARABEE SYSTEMS CENTRALIZED SERVER25 ASL ELECTRICAL LAYOUT SMITHS DETECTION26 ASL ELECTRICAL DEVICES SMITHS DETECTION27 ASL DATA LAYOUT SMITHS DETECTION STANDALONE28 ASL DATA LAYOUT SMITHS DETECTION CENTRALIZED SERVER29 ASL ELECTRICAL LAYOUT RAPISCAN SYSTEMS30 ASL ELECTRICAL DEVICES RAPISCAN SYSTEMS31 ASL DATA LAYOUT RAPISCAN SYSTEMS STANDALONE32 ASL DATA LAYOUT RAPISCAN SYSTEMS CENTRALIZED SERVER33 DATA CABLE REQUIREMENTS - AT/CT34 DATA CABLE REQUIREMENTS - ASL35 NETWORK REQUIREMENTS36 CONDUCTOR REQUIREMENTS37 POWER DATA STANCHION38 POWER DATA SURFACE MOUNT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL AND DATA DESIGN-COVER
AutoCAD SHX TextNOTE: REFERENCE CHECKPOINT DESIGN GUIDE 6.1 FOR ADDITIONAL ELECTRICAL AND DATA REQUIREMENTS FOR A COMPLETE CHECKPOINT INSTALLATION.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text1
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextX-RAY
AutoCAD SHX Text620DV AT2
AutoCAD SHX TextRAPISCAN
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextX-RAY
AutoCAD SHX Text6040 aTiX
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextX-RAY
AutoCAD SHX Text6040 aTiX
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextFRONT XRAY OUTLET (A)
AutoCAD SHX TextREAR XRAY OUTLET (B)
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextQUEUE CONV.
AutoCAD SHX TextCONVENIENCE
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextAIT
AutoCAD SHX TextAT XRAY
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextAT 1
AutoCAD SHX TextAT 2
AutoCAD SHX TextAVS/AT 1
AutoCAD SHX TextAVS/AT 2
AutoCAD SHX TextAIT 1
AutoCAD SHX TextAIT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextBLANK/ EXPANDABLE
AutoCAD SHX TextAVS/ETD/BLS/AVS/AVS (C)
AutoCAD SHX TextAVS/AT 1
AutoCAD SHX TextAVS/AT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAVS/AT 1
AutoCAD SHX TextAVS/AT 2
AutoCAD SHX TextBLS 1
AutoCAD SHX TextBLS 2
AutoCAD SHX TextPRIVATE SCREENING ROOM (E)
AutoCAD SHX TextPSR 1
AutoCAD SHX TextPSR 2
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextDUPLEX DEDICATED FOR PSR ONLY
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED POWER STRIP ONLY
AutoCAD SHX TextCT SCANNER
AutoCAD SHX TextDEDICATED DEVICE TBD
AutoCAD SHX Text208/240 1PHASE 20 OR 30 AMP
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURESS ALARM & CHRONOS CLOCK (F)
AutoCAD SHX TextDEDICATED REPEATER ONLY
AutoCAD SHX TextPOTS
AutoCAD SHX TextPHONE LINE
AutoCAD SHX TextDEDICATED RECEIVER ONLY
AutoCAD SHX TextRECEIVER
AutoCAD SHX TextCHRONOS CLOCK
AutoCAD SHX TextDATA LINES
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextETD1
AutoCAD SHX TextSPARE
AutoCAD SHX TextPOWER REQUIREMENTS
AutoCAD SHX TextEQUIPMENT
AutoCAD SHX TextMAX NUMBER OF EQUIPMENT ALLOWED PER DEDICATED CIRCUIT
AutoCAD SHX TextNOTES
AutoCAD SHX TextTDC [CAT/E GATE/BAT]
AutoCAD SHX Text1
AutoCAD SHX Text1 20A CIRCUIT DEDICATED, 2 LOCATIONS PER LANE
AutoCAD SHX TextWTMD
AutoCAD SHX Text10
AutoCAD SHX TextL5-15R SIMPLEX RECEPTACLE
AutoCAD SHX TextAT X-RAY
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextQUEUING CONVEYOR
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH CO-LOCATED ETD OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAIT
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text1
AutoCAD SHX TextRECEPTACLE TO BE DETERMINED, PROVIDE DEDICATED 208/240 1PHASE 20 OR 30AMP
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH QUEUING CONVEYOR OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAVS/ETD/BLS/AVS
AutoCAD SHX Text1 SHARED LOCATION
AutoCAD SHX TextOUTLET(S) POWERS RELOCATEABLE POWER TAP
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX Text1
AutoCAD SHX TextONE OUTLET INSIDE AND ONE OUTLET OUTSIDE OF PRIVATE SCREENING ROOM
AutoCAD SHX TextSTSO PODIUM
AutoCAD SHX Text2
AutoCAD SHX TextPROVIDE DUPLEX OUTLET
AutoCAD SHX TextIT CABINET
AutoCAD SHX Text1
AutoCAD SHX Text30A L5-30R RECEPTACLE
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO REPEATERS PER DUPLEX
AutoCAD SHX TextDURESS ALARM REPEATER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO PER DUPLEX
AutoCAD SHX TextGENERIC POWER POLE DEVICE SYMBOL
AutoCAD SHX TextGENERIC RECESSED FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC MODULAR FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL POTS PHONE LINE SYMBOL
AutoCAD SHX TextGENERIC WALL DATA DEVICE SYMBOL
AutoCAD SHX TextOR
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EQUIPMENT SHOWN REPRESENTS TWO DIFFERENT X-RAY MANUFACTURERS FOR EXAMPLE EQUIPMENT SHOWN REPRESENTS TWO DIFFERENT X-RAY MANUFACTURERS FOR EXAMPLE OF OUTLET PLACEMENT, EACH CHECKPOINT TYPICALLY INCLUDES ONLY ONE MANUFACTURER. 2. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 3. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 4. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.)
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL DESIGN-AT2
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 1
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
NOTES BY SYMBOL " "
X-RAY DEVICE LOCATIONS
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text1
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextX-RAY
AutoCAD SHX Text620DV AT2
AutoCAD SHX TextRAPISCAN
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextX-RAY
AutoCAD SHX Text6040 aTiX
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX Text"POTS PHONE LINE"
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextX-RAY
AutoCAD SHX Text6040 aTiX
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextPASSENGER FLOW
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX Text1
AutoCAD SHX TextX-RAY UNIT CENTERLINE
AutoCAD SHX Text4
AutoCAD SHX TextCOORDINATE WITH ALARM BAG CUTOUT
AutoCAD SHX Text1
AutoCAD SHX TextCT/AT MACHINE BODY
AutoCAD SHX TextPOWER POLE ON OPERATOR SIDE OF X-RAY UNIT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EQUIPMENT SHOWN REPRESENTS TWO DIFFERENT X-RAY MANUFACTURERS FOR EXAMPLE EQUIPMENT SHOWN REPRESENTS TWO DIFFERENT X-RAY MANUFACTURERS FOR EXAMPLE OF OUTLET PLACEMENT, EACH CHECKPOINT TYPICALLY INCLUDES ONLY ONE MANUFACTURER. 2. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 3. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 4. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 5. AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF NECESSARY.
AutoCAD SHX TextTSA CHECKPOINT DATA TYPOLOGY -AT2
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 2
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX Text1. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. 2. ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN HATCHED AREA. 3. ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH DEVICE SERVING WTMD IF PREFERRED LOCATION EXCEEDS 13'-0" CORD LENGTH. 4. PREFERRED LOCATION OF POWER POLE. COORDINATE POWER PREFERRED LOCATION OF POWER POLE. COORDINATE POWER POLE LOCATION WITH ANY INTERFERING CEILING EQUIPMENT SUCH AS LIGHT FIXTURES, DIFFUSERS, GRILLES, SPRINKLER HEADS, ETC.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURESS ALARM & CHRONOS CLOCK (F)
AutoCAD SHX TextDEDICATED REPEATER ONLY
AutoCAD SHX TextPOTS
AutoCAD SHX TextPHONE LINE
AutoCAD SHX TextDEDICATED RECEIVER ONLY
AutoCAD SHX TextRECEIVER
AutoCAD SHX TextCHRONOS CLOCK
AutoCAD SHX TextDATA LINES
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextETD1
AutoCAD SHX TextSPARE
AutoCAD SHX TextPOWER REQUIREMENTS
AutoCAD SHX TextEQUIPMENT
AutoCAD SHX TextMAX NUMBER OF EQUIPMENT ALLOWED PER DEDICATED CIRCUIT
AutoCAD SHX TextNOTES
AutoCAD SHX TextTDC [CAT/E GATE/BAT]
AutoCAD SHX Text1
AutoCAD SHX Text1 20A CIRCUIT DEDICATED, 2 LOCATIONS PER LANE
AutoCAD SHX TextWTMD
AutoCAD SHX Text10
AutoCAD SHX TextL5-15R SIMPLEX RECEPTACLE
AutoCAD SHX TextAT X-RAY
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextQUEUING CONVEYOR
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH CO-LOCATED ETD OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAIT
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text1
AutoCAD SHX TextRECEPTACLE TO BE DETERMINED, PROVIDE DEDICATED 208/240 1PHASE 20AMP
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH QUEUING CONVEYOR OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAVS/ETD/BLS/AVS
AutoCAD SHX Text1 SHARED LOCATION
AutoCAD SHX TextOUTLET(S) POWERS RELOCATEABLE POWER TAP
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX Text1
AutoCAD SHX TextONE OUTLET INSIDE AND ONE OUTLET OUTSIDE OF PRIVATE SCREENING ROOM
AutoCAD SHX TextSTSO PODIUM
AutoCAD SHX Text2
AutoCAD SHX TextPROVIDE DUPLEX OUTLET
AutoCAD SHX TextIT CABINET
AutoCAD SHX Text1
AutoCAD SHX Text30A L5-30R RECEPTACLE
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO REPEATERS PER DUPLEX
AutoCAD SHX TextDURESS ALARM REPEATER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO PER DUPLEX
AutoCAD SHX TextGENERIC POWER POLE DEVICE SYMBOL
AutoCAD SHX TextGENERIC RECESSED FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC MODULAR FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL POTS PHONE LINE SYMBOL
AutoCAD SHX TextGENERIC WALL DATA DEVICE SYMBOL
AutoCAD SHX TextOR
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextFRONT XRAY OUTLET (A)
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextQUEUE CONV.
AutoCAD SHX TextCONVENIENCE
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextBLANK/ EXPANDABLE
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextAVS/ETD/BLS/AVS/AVS (C)
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextBLS 1
AutoCAD SHX TextBLS 2
AutoCAD SHX TextPRIVATE SCREENING ROOM (E)
AutoCAD SHX TextPSR 1
AutoCAD SHX TextPSR 2
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDUPLEX DEDICATED FOR PSR ONLY
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED POWER STRIP ONLY
AutoCAD SHX TextREAR XRAY OUTLET (B)
AutoCAD SHX TextCT 1
AutoCAD SHX TextCT 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextAIT 1
AutoCAD SHX TextAIT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAIT
AutoCAD SHX TextAT XRAY
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextSPARE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text208/240 1PHASE 20 AMP
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL DESIGN - L3 CT CLEARSCAN
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 3
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
NOTES BY SYMBOL " "
X-RAY DEVICE LOCATIONS
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX Text"POTS PHONE LINE"
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX TextL3
AutoCAD SHX TextCLEAR-SCAN
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextPASSENGER FLOW
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX Text1
AutoCAD SHX TextX-RAY UNIT CENTERLINE
AutoCAD SHX Text4
AutoCAD SHX TextCOORDINATE WITH ALARM BAG CUTOUT
AutoCAD SHX Text1
AutoCAD SHX TextCT/AT MACHINE BODY
AutoCAD SHX TextPOWER POLE ON OPERATOR SIDE OF X-RAY UNIT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF NECESSARY.
AutoCAD SHX TextTSA CHECKPOINT DATA TYPOLOGY - CT L3 CLEARSCAN
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 4
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX Text1. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. 2. ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN HATCHED AREA. 3. ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH DEVICE SERVING WTMD IF PREFERRED LOCATION EXCEEDS 13'-0" CORD LENGTH. 4. PREFERRED LOCATION OF POWER POLE. COORDINATE POWER PREFERRED LOCATION OF POWER POLE. COORDINATE POWER POLE LOCATION WITH ANY INTERFERING CEILING EQUIPMENT SUCH AS LIGHT FIXTURES, DIFFUSERS, GRILLES, SPRINKLER HEADS, ETC.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text4
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text4
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURESS ALARM & CHRONOS CLOCK (F)
AutoCAD SHX TextDEDICATED REPEATER ONLY
AutoCAD SHX TextPOTS
AutoCAD SHX TextPHONE LINE
AutoCAD SHX TextDEDICATED RECEIVER ONLY
AutoCAD SHX TextRECEIVER
AutoCAD SHX TextCHRONOS CLOCK
AutoCAD SHX TextDATA LINES
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextETD1
AutoCAD SHX TextSPARE
AutoCAD SHX TextPOWER REQUIREMENTS
AutoCAD SHX TextEQUIPMENT
AutoCAD SHX TextMAX NUMBER OF EQUIPMENT ALLOWED PER DEDICATED CIRCUIT
AutoCAD SHX TextNOTES
AutoCAD SHX TextTDC [CAT/E GATE/BAT]
AutoCAD SHX Text1
AutoCAD SHX Text1 20A CIRCUIT DEDICATED, 2 LOCATIONS PER LANE
AutoCAD SHX TextWTMD
AutoCAD SHX Text10
AutoCAD SHX TextL5-15R SIMPLEX RECEPTACLE
AutoCAD SHX TextAT X-RAY
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextQUEUING CONVEYOR
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH CO-LOCATED ETD OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAIT
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text1
AutoCAD SHX TextRECEPTACLE TO BE DETERMINED, PROVIDE DEDICATED 208/240 1PHASE 30AMP
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH QUEUING CONVEYOR OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAVS/ETD/BLS/AVS
AutoCAD SHX Text1 SHARED LOCATION
AutoCAD SHX TextOUTLET(S) POWERS RELOCATEABLE POWER TAP
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX Text1
AutoCAD SHX TextONE OUTLET INSIDE AND ONE OUTLET OUTSIDE OF PRIVATE SCREENING ROOM
AutoCAD SHX TextSTSO PODIUM
AutoCAD SHX Text2
AutoCAD SHX TextPROVIDE DUPLEX OUTLET
AutoCAD SHX TextIT CABINET
AutoCAD SHX Text1
AutoCAD SHX Text30A L5-30R RECEPTACLE
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO REPEATERS PER DUPLEX
AutoCAD SHX TextDURESS ALARM REPEATER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO PER DUPLEX
AutoCAD SHX TextGENERIC POWER POLE DEVICE SYMBOL
AutoCAD SHX TextGENERIC RECESSED FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC MODULAR FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL POTS PHONE LINE SYMBOL
AutoCAD SHX TextGENERIC WALL DATA DEVICE SYMBOL
AutoCAD SHX TextOR
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextFRONT XRAY OUTLET (A)
AutoCAD SHX TextREAR XRAY OUTLET (B)
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextQUEUE CONV.
AutoCAD SHX TextCONVENIENCE
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextCT 1
AutoCAD SHX TextCT 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextAIT 1
AutoCAD SHX TextAIT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextBLANK/ EXPANDABLE
AutoCAD SHX TextAVS/ETD/BLS/AVS/AVS (C)
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextBLS 1
AutoCAD SHX TextBLS 2
AutoCAD SHX TextPRIVATE SCREENING ROOM (E)
AutoCAD SHX TextPSR 1
AutoCAD SHX TextPSR 2
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextDUPLEX DEDICATED FOR PSR ONLY
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED POWER STRIP ONLY
AutoCAD SHX TextAIT
AutoCAD SHX TextAT XRAY
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextSPARE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text208/240 1PHASE 30 AMP
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL DESIGN - IDSS CT DETECT 1000
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 5
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
NOTES BY SYMBOL " "
X-RAY DEVICE LOCATIONS
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextL
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX Text"POTS PHONE LINE"
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX Text3
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text4
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX TextDETECT 1000
AutoCAD SHX TextTABLE 24x24 S.S.
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextLANE 1
AutoCAD SHX TextLANE 2
AutoCAD SHX TextLANE 3
AutoCAD SHX TextPASSENGER FLOW
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX Text1
AutoCAD SHX TextX-RAY UNIT CENTERLINE
AutoCAD SHX Text4
AutoCAD SHX TextCOORDINATE WITH ALARM BAG CUTOUT
AutoCAD SHX Text1
AutoCAD SHX TextCT/AT MACHINE BODY
AutoCAD SHX TextPOWER POLE ON OPERATOR SIDE OF X-RAY UNIT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF NECESSARY.
AutoCAD SHX TextTSA CHECKPOINT DATA TYPOLOGY - IDSS CT DETECT 1000
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 6
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX Text1. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. 2. ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN HATCHED AREA. 3. ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH DEVICE SERVING WTMD IF PREFERRED LOCATION EXCEEDS 13'-0" CORD LENGTH. 4. PREFERRED LOCATION OF POWER POLE. COORDINATE POWER PREFERRED LOCATION OF POWER POLE. COORDINATE POWER POLE LOCATION WITH ANY INTERFERING CEILING EQUIPMENT SUCH AS LIGHT FIXTURES, DIFFUSERS, GRILLES, SPRINKLER HEADS, ETC.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX TextLANE 1
AutoCAD SHX TextLANE 2
AutoCAD SHX TextLANE 3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURESS ALARM & CHRONOS CLOCK (F)
AutoCAD SHX TextDEDICATED REPEATER ONLY
AutoCAD SHX TextPOTS
AutoCAD SHX TextPHONE LINE
AutoCAD SHX TextDEDICATED RECEIVER ONLY
AutoCAD SHX TextRECEIVER
AutoCAD SHX TextCHRONOS CLOCK
AutoCAD SHX TextDATA LINES
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextETD1
AutoCAD SHX TextSPARE
AutoCAD SHX TextPOWER REQUIREMENTS
AutoCAD SHX TextEQUIPMENT
AutoCAD SHX TextMAX NUMBER OF EQUIPMENT ALLOWED PER DEDICATED CIRCUIT
AutoCAD SHX TextNOTES
AutoCAD SHX TextTDC [CAT/E GATE/BAT]
AutoCAD SHX Text1
AutoCAD SHX Text1 20A CIRCUIT DEDICATED, 2 LOCATIONS PER LANE
AutoCAD SHX TextWTMD
AutoCAD SHX Text10
AutoCAD SHX TextL5-15R SIMPLEX RECEPTACLE
AutoCAD SHX TextAT X-RAY
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextQUEUING CONVEYOR
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH CO-LOCATED ETD OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAIT
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text1
AutoCAD SHX TextRECEPTACLE TO BE DETERMINED, PROVIDE DEDICATED 208/240 1PHASE 30AMP
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH QUEUING CONVEYOR OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAVS/ETD/BLS/AVS
AutoCAD SHX Text1 SHARED LOCATION
AutoCAD SHX TextOUTLET(S) POWERS RELOCATEABLE POWER TAP
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX Text1
AutoCAD SHX TextONE OUTLET INSIDE AND ONE OUTLET OUTSIDE OF PRIVATE SCREENING ROOM
AutoCAD SHX TextSTSO PODIUM
AutoCAD SHX Text2
AutoCAD SHX TextPROVIDE DUPLEX OUTLET
AutoCAD SHX TextIT CABINET
AutoCAD SHX Text1
AutoCAD SHX Text30A L5-30R RECEPTACLE
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO REPEATERS PER DUPLEX
AutoCAD SHX TextDURESS ALARM REPEATER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO PER DUPLEX
AutoCAD SHX TextGENERIC POWER POLE DEVICE SYMBOL
AutoCAD SHX TextGENERIC RECESSED FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC MODULAR FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL POTS PHONE LINE SYMBOL
AutoCAD SHX TextGENERIC WALL DATA DEVICE SYMBOL
AutoCAD SHX TextOR
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextFRONT XRAY OUTLET (A)
AutoCAD SHX TextREAR XRAY OUTLET (B)
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextQUEUE CONV.
AutoCAD SHX TextCONVENIENCE
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextCT 1
AutoCAD SHX TextCT 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextAIT 1
AutoCAD SHX TextAIT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextBLANK/ EXPANDABLE
AutoCAD SHX TextAVS/ETD/BLS/AVS/AVS (C)
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextBLS 1
AutoCAD SHX TextBLS 2
AutoCAD SHX TextPRIVATE SCREENING ROOM (E)
AutoCAD SHX TextPSR 1
AutoCAD SHX TextPSR 2
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextDUPLEX DEDICATED FOR PSR ONLY
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED POWER STRIP ONLY
AutoCAD SHX TextAIT
AutoCAD SHX TextAT XRAY
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextSPARE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text208/240 1PHASE 30 AMP
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL DESIGN - ANALOGIC CT CONNECT
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 7
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
NOTES BY SYMBOL " "
X-RAY DEVICE LOCATIONS
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextR
AutoCAD SHX TextL
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX Text"POTS PHONE LINE"
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX TextANALOGIC
AutoCAD SHX TextCONNECT
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextPASSENGER FLOW
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX Text1
AutoCAD SHX TextX-RAY UNIT CENTERLINE
AutoCAD SHX Text4
AutoCAD SHX TextCOORDINATE WITH ALARM BAG CUTOUT
AutoCAD SHX Text1
AutoCAD SHX TextCT/AT MACHINE BODY
AutoCAD SHX TextPOWER POLE ON OPERATOR SIDE OF X-RAY UNIT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF NECESSARY.
AutoCAD SHX TextTSA CHECKPOINT DATA TYPOLOGY - ANALOGIC CT CONNECT
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 8
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX Text1. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. 2. ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN HATCHED AREA. 3. ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH DEVICE SERVING WTMD IF PREFERRED LOCATION EXCEEDS 13'-0" CORD LENGTH. 4. PREFERRED LOCATION OF POWER POLE. COORDINATE POWER PREFERRED LOCATION OF POWER POLE. COORDINATE POWER POLE LOCATION WITH ANY INTERFERING CEILING EQUIPMENT SUCH AS LIGHT FIXTURES, DIFFUSERS, GRILLES, SPRINKLER HEADS, ETC.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURESS ALARM & CHRONOS CLOCK (F)
AutoCAD SHX TextDEDICATED REPEATER ONLY
AutoCAD SHX TextPOTS
AutoCAD SHX TextPHONE LINE
AutoCAD SHX TextDEDICATED RECEIVER ONLY
AutoCAD SHX TextRECEIVER
AutoCAD SHX TextCHRONOS CLOCK
AutoCAD SHX TextDATA LINES
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextETD1
AutoCAD SHX TextSPARE
AutoCAD SHX TextPOWER REQUIREMENTS
AutoCAD SHX TextEQUIPMENT
AutoCAD SHX TextMAX NUMBER OF EQUIPMENT ALLOWED PER DEDICATED CIRCUIT
AutoCAD SHX TextNOTES
AutoCAD SHX TextTDC [CAT/E GATE/BAT]
AutoCAD SHX Text1
AutoCAD SHX Text1 20A CIRCUIT DEDICATED, 2 LOCATIONS PER LANE
AutoCAD SHX TextWTMD
AutoCAD SHX Text10
AutoCAD SHX TextL5-15R SIMPLEX RECEPTACLE
AutoCAD SHX TextAT X-RAY
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextQUEUING CONVEYOR
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH CO-LOCATED ETD OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAIT
AutoCAD SHX Text1
AutoCAD SHX TextPROVIDE SIMPLEX RECEPTACLE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text1
AutoCAD SHX TextRECEPTACLE TO BE DETERMINED, PROVIDE DEDICATED 208/240 1PHASE 20AMP
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text2
AutoCAD SHX TextMAY BE SHARED WITH QUEUING CONVEYOR OUTLET WITHIN THE SAME MODULE SET
AutoCAD SHX TextAVS/ETD/BLS/AVS
AutoCAD SHX Text1 SHARED LOCATION
AutoCAD SHX TextOUTLET(S) POWERS RELOCATEABLE POWER TAP
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX Text1
AutoCAD SHX TextONE OUTLET INSIDE AND ONE OUTLET OUTSIDE OF PRIVATE SCREENING ROOM
AutoCAD SHX TextSTSO PODIUM
AutoCAD SHX Text2
AutoCAD SHX TextPROVIDE DUPLEX OUTLET
AutoCAD SHX TextIT CABINET
AutoCAD SHX Text1
AutoCAD SHX Text30A L5-30R RECEPTACLE
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO REPEATERS PER DUPLEX
AutoCAD SHX TextDURESS ALARM REPEATER PANEL
AutoCAD SHX Text2
AutoCAD SHX TextCIRCUITS SHARED CAN BE MORE THAN TWO THROUGHOUT CHECKPOINT BUT ONLY CAN INSTALL TWO PER DUPLEX
AutoCAD SHX TextGENERIC POWER POLE DEVICE SYMBOL
AutoCAD SHX TextGENERIC RECESSED FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC MODULAR FLOOR DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL DEVICE SYMBOL
AutoCAD SHX TextGENERIC WALL POTS PHONE LINE SYMBOL
AutoCAD SHX TextGENERIC WALL DATA DEVICE SYMBOL
AutoCAD SHX TextOR
AutoCAD SHX TextWTMD 1
AutoCAD SHX TextFRONT XRAY OUTLET (A)
AutoCAD SHX TextWTMD 2
AutoCAD SHX TextQUEUE CONV.
AutoCAD SHX TextCONVENIENCE
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextBLANK/ EXPANDABLE
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextDEDICATED ETD & QUEUE ONLY
AutoCAD SHX TextAVS/ETD/BLS/AVS/AVS (C)
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextBLS 1
AutoCAD SHX TextBLS 2
AutoCAD SHX TextPRIVATE SCREENING ROOM (E)
AutoCAD SHX TextPSR 1
AutoCAD SHX TextPSR 2
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDUPLEX DEDICATED FOR PSR ONLY
AutoCAD SHX TextETD/BLS/AVS TO POWER STRIP
AutoCAD SHX TextDEDICATED POWER STRIP ONLY
AutoCAD SHX TextREAR XRAY OUTLET (B)
AutoCAD SHX TextCT 1
AutoCAD SHX TextCT 2
AutoCAD SHX TextAVS/CT 1
AutoCAD SHX TextAVS/CT 2
AutoCAD SHX TextAIT 1
AutoCAD SHX TextAIT 2
AutoCAD SHX TextETD 1
AutoCAD SHX TextETD 2
AutoCAD SHX TextAIT
AutoCAD SHX TextAT XRAY
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextSPARE
AutoCAD SHX TextCT SCANNER
AutoCAD SHX Text208/240 1PHASE 20 AMP
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS THIS CONFIGURATION IS FOR STANDALONE CT INSTALLATIONS, SEE ASL CONFIGURATIONS FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX TextTSA CHECKPOINT ELECTRICAL DESIGN - SMITHS DETECTION CT
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 9
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX TextOPTIONAL 120V/ 30A, SEE OEM REQUIREMENTS
NOTES BY SYMBOL " "
X-RAY DEVICE LOCATIONS
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextR
AutoCAD SHX TextL
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX Text"POTS PHONE LINE"
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text6 x CAT 6
AutoCAD SHX Text2 x CAT 6
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX Text3
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX TextETD
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX TextSMITHS DETECTION HI-SCAN 6040 CTiX
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX Text4 x CAT 6
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextPASSENGER FLOW
AutoCAD SHX Text3
AutoCAD SHX Text2
AutoCAD SHX Text1
AutoCAD SHX TextX-RAY UNIT CENTERLINE
AutoCAD SHX Text4
AutoCAD SHX TextCOORDINATE WITH ALARM BAG CUTOUT
AutoCAD SHX Text1
AutoCAD SHX TextCT/AT MACHINE BODY
AutoCAD SHX TextPOWER POLE ON OPERATOR SIDE OF X-RAY UNIT
AutoCAD SHX TextU.S DEPARTMENT OF HOMELAND SECURITY
AutoCAD SHX TextD:\TEDS\!CDG\Electrical Diagram.dwg
AutoCAD SHX Text601 SOUTH 12TH STREET, ARLINGTON, VA 22202
AutoCAD SHX TextREVISION 19 - ISSUED MAY 10, 2018
AutoCAD SHX TextNOTES: 1. EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, EACH EQUIPMENT LOCATION SHALL UTILIZE EITHER FLOOR OUTLETS OR POWER POLES, BUT NOT BOTH TYPES OF POWER/DATA DEVICES (SELECTION DEPENDS ON AIRPORT BUILDING CONSTRUCTION.) 2. IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO IT IS RECOMMENDED THAT THE PRIVATE SCREENING ROOM, IT ROOM, AND THE STSO PODIUM BE BUILT INTO THE SPACE OF THE AIRPORT. 3. POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, POWER/DATA DEVICES SHOWN ARE REPRESENTATIVE OF THE TYPICAL OUTLETS REQUIRED, REFER TO THE CHECKPOINT DESIGN GUIDE FOR ALTERNATIVE TYPES OF POWER/DATA DEVICES (POWER POLES, MODULAR BOXES, ETC.) 4. AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF AVS DATA LINES FROM THE REAR XRAY OUTLET MAY ROUTE THRU THE IT ROOM IF NECESSARY.
AutoCAD SHX TextTSA CHECKPOINT DATA TYPOLOGY - SMITHS DETECTION CT
AutoCAD SHX TextSPECIAL SCOPE NOTE: PLEASE NOTE THAN ANY COSTS ASSOCIATED WITH THE PLANNING, DESIGN AND/OR OTHER ASPECTS OF THIS PROJECT ARE THE SOLE RESPONSIBILITY OF THE AIRPORT AND/OR AIRLINE AND TSA WILL NOT BE LIABLE FOR ANY COSTS OR REIMBURSEMENT FOR ANY ASPECT OF THE PROJECT.
AutoCAD SHX TextSHEET 10
AutoCAD SHX TextSPECIAL IT NOTE: ALL IT ROOMS, I/O ROOMS AND PRIVATE SCREENING ROOMS ARE NON-LEASED SPACE. ALL IT ROOMS NEED TO BE CLEARED THROUGH LOCAL/TSA HQ IT AND TSA HQ OFFICE OF REAL ESTATE FOR AWARENESS. THE LOCAL TSA IS RESPONSIBLE TO MAKE ALL NOTIFICATIONS.
AutoCAD SHX Text1. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. PREFERRED LOCATION OF SURFACE OR FLUSH DEVICE. 2. ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN ACCEPTABLE LOCATION OF SURFACE OR FLUSH DEVICE WITHIN HATCHED AREA. 3. ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH ACCEPTABLE ALTERNATE LOCATION OF SURFACE OR FLUSH DEVICE SERVING WTMD IF PREFERRED LOCATION EXCEEDS 13'-0" CORD LENGTH. 4. PREFERRED LOCATION OF POWER POLE. COORDINATE POWER PREFERRED LOCATION OF POWER POLE. COORDINATE POWER POLE LOCATION WITH ANY INTERFERING CEILING EQUIPMENT SUCH AS LIGHT FIXTURES, DIFFUSERS, GRILLES, SPRINKLER HEADS, ETC.
AutoCAD SHX TextSTANDARD POWER/DATA LAYOUT
AutoCAD SHX TextREVISED 5/9/185/9/18
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 3
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text3
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTABLE630
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextR
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 2
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextTABLE630
AutoCAD SHX TextTABLE630
AutoCAD SHX TextLANE 1
AutoCAD SHX TextL
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text2
AutoCAD SHX TextL3
AutoCAD SHX TextAIT
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextTCOP
AutoCAD SHX TextL
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX Text3
AutoCAD SHX Text1
AutoCAD SHX TextETD
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextAVS
AutoCAD SHX TextETD
AutoCAD SHX TextBLS
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextSTSO
AutoCAD SHX TextAVS
AutoCAD SHX TextAVS
AutoCAD SHX TextIT
AutoCAD SHX TextRACK
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextFRONT X-RAY OUTLET (A)(A)
AutoCAD SHX TextREAR X-RAY FLOOR OUTLET (B) (B)
AutoCAD SHX TextREAR X-RAY OUTLET (B) (B)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS OUTLET (C) (C)
AutoCAD SHX TextPRIVATE SCREENING ROOM OUTLET & POWER POLE (E) (E)
AutoCAD SHX TextSINGLE LANE WALL OUTLET (D) (D)
AutoCAD SHX TextSTSO WALL OUTLET (MAY BE FLUSH MOUNTED)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextREAR X-RAY POWER POLE (B) (B)
AutoCAD SHX TextPRIVATE SCREENING ROOM
AutoCAD SHX TextIT ROOM LOCATION VARIES
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextFRONT X-RAY POWER POLE (A)(A)
AutoCAD SHX TextAVS/ETD/BLS POWER POLE (C) (C)
AutoCAD SHX TextAVS/ETD/BLS/AVS POWER POLE (C) (C)
AutoCAD SHX TextSINGLE LANE POWER POLE (D) (D)
AutoCAD SHX TextSTSO POWER POLE
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextIT RACK POWER POLE
AutoCAD SHX TextIT RACK OUTLET
AutoCAD SHX TextDURESS ALARM RECEIVER PANEL WALL OUTLET (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL POWER POLE (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextDURESS ALARM REPEATER PANEL WALL OUTLET (GENERAL LOCATION AND QUANTITY PER CHECKPOINT TBD)
AutoCAD SHX TextPOTS PHONE LINE (GENERAL LOCATION TBD)
AutoCAD SHX TextDATA LINE FOR CHRONOS CLOCK (F) (F) (GENERAL LOCATION TBD)
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX Text*NOTE: MORE THAN ONE REPEATER MAY BE NECESSARY PER CHECKPOINT
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX TextBINS
AutoCAD SHX TextEMPTY
AutoCAD SHX Text1
AutoCAD SHX TextR
AutoCAD SHX TextADA GATE
AutoCAD SHX TextWTMD CEIA
AutoCAD SHX TextL3 PROVISION2 AIT2
AutoCAD SHX TextENTER
AutoCAD SHX TextEXIT
AutoCAD SHX TextETD
AutoCAD SHX Text1
AutoCAD SHX Text1
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextTDC/CAT OUTLET (G) (G)
AutoCAD SHX TextTDC/CAT POWER POLE (G) (G)
AutoCAD SHX TextScan Tech
AutoCAD SHX TextSentinel III
AutoCAD SHX TextScan Tech
AutoCAD SHX TextSentinel III
AutoCAD SHX TextScan Tech
AutoCAD SHX TextSentinel III
AutoCAD SHX TextTDC1 A
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 B
AutoCAD SHX TextTDC2 A
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC/ ETD
AutoCAD SHX TextTDC [CAT/E GATE/BAT], STSO (G)
AutoCAD SHX TextDEDICATED, 2 PER LANE FOR TDC LOCATONS
AutoCAD SHX TextAIT
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextCO-LOCATED ETD
AutoCAD SHX TextDEDICATED
AutoCAD SHX TextL5-15R SIMPLEX
AutoCAD SHX TextWTMD
AutoCAD SHX TextDEDICATED WTMD ONLY
AutoCAD SHX TextSINGLE LANE WALL (D)
AutoCAD SHX TextREPEATER
AutoCAD SHX TextDURES