22
The Generang Set The complete generang set is mounted as a whole onto a heavy duty fabricated steel baseframe. An-vibraon pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibraon isolaon of the rotang assembly. Stringent factory tests are carried out on the generang set, with a full load test completed prior to despatch. All protecve devices, control funcons and site load condions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design. Control System The control starng system is an Auto-Start Control Module and is fied standard. Starng is remote or local to the machine with push Start/Stop buon and includes the following: Alternator frequency & speed sensing Fully configurable via the interface or PC using USB Generator/load power monitoring Accumulated power monitoring Generator overload protecon Fuel and start outputs Engine speed protecon Engine run-me scheduler Baery voltage monitoring Stac baery charger Can also be configured to operate with an Automac Transfer Switch with logic. Engine Kubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme condions. Whatever you throw at them, you just know they’ll keep working day aſter day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian condions. The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internaonally recognised Australian leader in the manufacture and supply of diesel generang sets for industrial or commercial applicaons. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products. We have the experse to provide sound advice on your power generang needs. Whether your requirements are prime (connuous) power or standby power applicaons, you can choose from our standard build sets, or we can tailor to suit your applicaon requirements. Model: ED8.8KYE 8.8kVA www.wellcross.com.au Powered by Alternator Crossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotang field design and are self-excited with power derived from main output windings using the Automac Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminaons impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starng and short circuit protecon of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V). Image may vary from actual model.
Transcript
Page 1: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED8.8KYE

8.8kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 2: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2000 x 900 x 1153 mmWeight 700 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 71 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED8.8KYE

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model D1105Engine Speed 1500 rpmCylinders 3Cubic Capacity 1.498 LBore/Stroke 78 x 78.4 mmCompression Ratio 21:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 8.4 kWCombustion Air Flow 1 m3/minCooling Air flow 35 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 8 kWExhaust Gas Flow 2.2 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 2.75 L/hFuel Consumption (Standby) 3.0 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Single PhaseActive Power 8.8 kVA at 0.8 pf

(Standby)Power 7.04 kWVoltage 240 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 3: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED9KYE/3

9kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 4: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2000 x 900 x 1153 mmWeight 700 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 71 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED9KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model D1105Engine Speed 1500 rpmCylinders 3Cubic Capacity 1.498 LBore/Stroke 78 x 78.4 mmCompression Ratio 21:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 8.4 kWCombustion Air Flow 1 m3/minCooling Air flow 35 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 8 kWExhaust Gas Flow 2.2 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 2.75 L/hFuel Consumption (Standby) 3.0 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 9 kVA at 0.8 pf

(Standby)Power 7.2 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 5: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED10.5KYE

10.5kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 6: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2000 x 900 x 1153 mmWeight 770 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 71 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED10.5KYE

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V1505Engine Speed 1500 rpmCylinders 4Cubic Capacity 1.498 LBore/Stroke 78 x 78.4 mmCompression Ratio 16.8:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 12.2 kWCombustion Air Flow 1.1 m3/minCooling Air flow 40 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 12 kWExhaust Gas Flow 2.5 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 2.9 L/hFuel Consumption (Standby) 3.2 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Single PhaseActive Power 10.5 kVA at 0.8 pf

(Standby)Power 8.4 kWVoltage 240 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 7: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED12KYE/3

12kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 8: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2000 x 900 x 1153 mmWeight 770 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 71 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED12KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V1505Engine Speed 1500 rpmCylinders 4Cubic Capacity 1.498 LBore/Stroke 78 x 78.4 mmCompression Ratio 16.8:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 12.2 kWCombustion Air Flow 1.1 m3/minCooling Air flow 40 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 12 kWExhaust Gas Flow 2.5 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 4.0 L/hFuel Consumption (Standby) 4.4 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 12 kVA at 0.8 pf

(Standby)Power 9.6 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 9: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED14.5KYE/3

14.5kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 10: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2000 x 900 x 1153 mmWeight 830 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 74 dB(A) at 1 metre from the machine (65 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED14.5KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model D1703Engine Speed 1500 rpmCylinders 3Cubic Capacity 1.647 LBore/Stroke 87 x 92.4 mmCompression Ratio 17:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 14 kWCombustion Air Flow 1.3 m3/minCooling Air flow 48 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 12.8 kWExhaust Gas Flow 3.4 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 4.1 L/hFuel Consumption (Standby) 4.6 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 14.5 kVA at 0.8 pf

(Standby)Power 11.6 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 11: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED18KYE

18kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 12: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2150 x 900 x 1153 mmWeight 880 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 78 dB(A) at 1 metre from the machine (70 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED18KYE

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V2203Engine Speed 1500 rpmCylinders 4Cubic Capacity 2.197 LBore/Stroke 87 x 92.4 mmCompression Ratio 16:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 19 kWCombustion Air Flow 1.6 m3/minCooling Air flow 55 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 17 kWExhaust Gas Flow 4.8 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 5.13 L/hFuel Consumption (Standby) 5.7 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Single PhaseActive Power 18 kVA at 0.8 pf

(Standby)Power 14.4 kWElectric Potential 240 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 13: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED20KYE/3

20kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 14: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2150 x 900 x 1153 mmWeight 880 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 78 dB(A) at 1 metre from the machine (70 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED20KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V2203Engine Speed 1500 rpmCylinders 4Cubic Capacity 2.197 LBore/Stroke 87 x 92.4 mmCompression Ratio 16:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 19 kWCombustion Air Flow 1.6 m3/minCooling Air flow 55 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 17 kWExhaust Gas Flow 4.8 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 5.13 L/hFuel Consumption (Standby) 5.7 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 20 kVA at 0.8 pf

(Standby)Power 16 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 15: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED24KYE

24kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 16: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2150 x 900 x 1153 mmWeight 900 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 80 dB(A) at 1 metre from the machine (73 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED24KYE

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V2003TEngine Speed 1500 rpmCylinders 4TCubic Capacity 2.0 LBore/Stroke 83 x 92.4 mmCompression Ratio 16:1Aspiration TurbochargedStarter Voltage 12 VFlywheel (Max. Continuous Power) 22.44 kWCombustion Air Flow 1.9 m3/minCooling Air flow 60 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 20.5 kWExhaust Gas Flow 4.2 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 6.1 L/hFuel Consumption (Standby) 6.71 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Single PhaseActive Power 24 kVA at 0.8 pf

(Standby)Power 19.2 kWElectric Potential 240 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 17: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED24KYE/3

24kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 18: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2150 x 900 x 1153 mmWeight 900 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 80 dB(A) at 1 metre from the machine (73 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED24KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V2003TEngine Speed 1500 rpmCylinders 4TCubic Capacity 2.0 LBore/Stroke 83 x 92.4 mmCompression Ratio 16:1Aspiration TurbochargedStarter Voltage 12 VFlywheel (Max. Continuous Power) 22.44 kWCombustion Air Flow 1.9 m3/minCooling Air flow 60 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 20.5 kWExhaust Gas Flow 4.2 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 6.1 L/hFuel Consumption (Standby) 6.71 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 24 kVA at 0.8 pf

(Standby)Power 19.2 kWVoltage 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 19: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED30KYE/3

30kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 20: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2300 x 1000 x 1373 mmWeight 1100 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 80 dB(A) at 1 metre from the machine (73 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED30KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V3300Engine Speed 1500 rpmCylinders 4Cubic Capacity 3.3 LBore/Stroke 98 x 110 mmCompression Ratio 16:1Aspiration NaturalStarter Voltage 12 VFlywheel (Max. Continuous Power) 26.3 kWCombustion Air Flow 2.1 m3/minCooling Air flow 60 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 23 kWExhaust Gas Flow 6.0 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 8.7 L/hFuel Consumption (Standby) 9.5 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 30 kVA at 0.8 pf

(Standby)Power 24 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.

Page 21: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

The Generating SetThe complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

Stringent factory tests are carried out on the generating set, with a full load test completed prior to despatch. All protective devices, control functions and site load conditions are simulated. The generator and its systems are thoroughly checked prior to leaving our factory. Warranty on the genset is for 12 months or 1000 hours from date of supply (whichever occurs first) and covers against faulty workmanship, materials and design.

Control SystemThe control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:• Alternator frequency & speed sensing• Fully configurable via the interface or PC using USB• Generator/load power monitoring• Accumulated power monitoring• Generator overload protection• Fuel and start outputs• Engine speed protection• Engine run-time scheduler• Battery voltage monitoring• Static battery chargerCan also be configured to operate with an Automatic Transfer Switch with logic.

EngineKubota has an unparalleled track record for providing reliable, hard-working and efficient engines that won’t let you down, even in the most extreme conditions. Whatever you throw at them, you just know they’ll keep working day after day. With over 90 years of proven performance, you can depend on a Kubota engine for uninterrupted performance, durability and unbeatable fuel economy. These engines are built tough, for our harsh Australian conditions.

The Diesel Generator ExpertsWelling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated since 1926, Welling & Crossley is an internationally recognised Australian leader in the manufacture and supply of diesel generating sets for industrial or commercial applications. Also available is a complete range of portable generators, inverter generators, back up generators, diesel engines and fire products.

We have the expertise to provide sound advice on your power generating needs. Whether your requirements are prime (continuous) power or standby power applications, you can choose from our standard build sets, or we can tailor to suit your application requirements.

Model: ED40KYE/3

40kVA

www.wellcross.com.au

Powered by

AlternatorCrossley SLG Series Alternators are single bearing, 4-pole, with a brushless, rotating field design and are self-excited with power derived from main output windings using the Automatic Voltage Regulator (AVR). Manufactured using the highest quality copper and steel with all laminations impregnated with epoxy resins, the SLG Series are of a modern design with a precision AVR that allows overloads of 10% for one hour in 12, and overloads for motor starting and short circuit protection of up to 300%. Available in either Single Phase (240V), 2-Phase (480V) or 3-Phase (415V).

Image may vary from actual model.

Page 22: 8.8kVA The Diesel Generator Experts...The Diesel Generator Experts Welling & Crossley is Australia’s largest diesel generator and engine specialist. Australian owned and operated

GENERATOR SPECIFICATIONSDimensions (L x W x H) 2300 x 1000 x 1373 mmWeight 1200 kg

These ratings are applicable for supplying continuous electrical power at variable load in the event of a utility power failure. No overload is permitted on these ratings.

CanopyA weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powdercoat paint finish, this acoustic canopy reduces the noise level of the generating set to approximately 80 dB(A) at 1 metre from the machine (73 dB(A) @ 7 m).

TECHNICAL SPECIFICATIONS

Specifications are subject to variation without notice.

Model: ED40KYE/3

Design Features• Heavy duty fabricated steel baseframe• Bunded Fuel Tank• Battery Charger• Control Panel with Emergency Stop button• Anti-vibration mounting pads fitted• Weather protected acoustic canopy

The generating set is load tested before dispatch.All protective devices control functions and site load conditions are simulated.

ENGINE SPECIFICATIONSEngine Model V3300TEngine Speed 1500 rpmCylinders 4TCubic Capacity 3.3 LBore/Stroke 98 x 110 mmCompression Ratio 16:1Aspiration TurbochargedStarter Voltage 12 VFlywheel (Max. Continuous Power) 36 kWCombustion Air Flow 2.8 m3/minCooling Air flow 80 m3/minCooling System Radiator CooledHeat Rejection to Cooling System 31 kWExhaust Gas Flow 8.0 m3/minExhaust Gas Temperature 550 °CFuel Type DieselFuel Tank Capacity 90 LFuel Consumption (Continuous) 9.4 L/hFuel Consumption (Standby) 10.4 L/h

ALTERNATOR SPECIFICATIONSAlternator Model CrossleyElectric Power Three PhaseActive Power 40 kVA at 0.8 pf

(Standby)Power 32 kWElectric Potential 415 VFrequency 50 Hz

Powered by

victoria new south wales queensland south australia western australia

1300 656 276www.wellcross.com.au

Note: Standby reference conditions 27°C (80°F) air inlet temperature 152.4 m (500ft) ASL. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with a specific gravity of 0.85 and conforming to BS29869:1988, Class A2.


Recommended