Date post: | 13-Apr-2015 |
Category: |
Documents |
Upload: | rajeshbodduna |
View: | 43 times |
Download: | 8 times |
WCDMA RAN and I-HSPA, Rel. RU30, Operating Documentation, Issue 05, Documentation Change Delivery 4
Equipment Lists for RNC2600
DN0938767
Issue 02BApproval Date 2012-02-09
Confidential
Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo-nents.
If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.
2 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d85d4Confidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2012. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.
DN0938767 3
Equipment Lists for RNC2600
Id:0900d805808d85d4Confidential
Table of contentsThis document has 34 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.2 Notations used in equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.1 Subracks and fan trays to the front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.2 Subracks for back interface units, panels, and cable supporting shelves to
the rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.3 Back interface unit for SF20/SFCO-A . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1.4 Back interface unit for SF20/SFA20. . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1.5 Back interface unit for MX1G6/-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1.6 Back interface unit for NP2GE-B/NP8S1-B . . . . . . . . . . . . . . . . . . . . . . 152.1.7 Installation set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.1.8 Setting modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.1.9 Cover plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.1.10 L3 Data collector mechanical set for RNC2600 RNAC. . . . . . . . . . . . . 162.2 RNAC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 172.3 RNAC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 212.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.1 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.1.1 Subracks and fan trays to the front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.1.2 Subracks for back interface units and cable supporting shelves to the rear
263.1.3 Back interface unit for MX1G6/-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.1.4 Back interface unit for NP8S1-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.1.5 Installation set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.1.6 Grounding set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.1.7 L3 Data collector mechanical set for RNC2600 RNBC. . . . . . . . . . . . . 293.2 RNBC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 303.3 RNBC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 333.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
4 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d85d4Confidential
List of figuresFigure 1 Notations used in the equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels . . . . . . . . . . . . . . . 13Figure 3 Functional units of the RNAC cabinet, capacity step 1 . . . . . . . . . . . . . . 17Figure 4 IPA2800 EC216 cabinet; the stickers in the figure, except the network ele-
ment name and marking strips,are attached to all cabinets . . . . . . . . . . 23Figure 5 IPA2800 EC216 cabinet, stickers equipped on delivery . . . . . . . . . . . . . 24Figure 6 Product collection and disposal within the European Union . . . . . . . . . . 25Figure 7 Grounding between RNAC and RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . 29Figure 8 Functional units of the RNBC cabinet, capacity steps 2 and 3 . . . . . . . . 30
DN0938767 5
Equipment Lists for RNC2600
Id:0900d805808d85d4Confidential
List of tablesTable 1 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 2 Subracks and fan trays to the front for the RNAC . . . . . . . . . . . . . . . . . 11Table 3 Subracks for back interfaces, connector panels, and cable supporting
shelves to the rear for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 4 Back interface unit for SF20/SFCO-A . . . . . . . . . . . . . . . . . . . . . . . . . . 13Table 5 Back interface unit for SF20/SFA20 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Table 6 Back interface unit for MX1G6/-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Table 7 Back interface unit for NP2GE-B/NP8S1-B . . . . . . . . . . . . . . . . . . . . . 15Table 8 Installation set EQIK216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Table 9 Setting modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Table 10 Cover plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Table 11 Panel brackets for cabinet EC216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Table 12 Connector panel for Ethernet interface . . . . . . . . . . . . . . . . . . . . . . . . . 16Table 13 Rubber covers for RJ-45 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . 16Table 14 Functional units, plug-in units, and memory modules of the RNAC . . . 18Table 15 Marking strips for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Table 16 Stickers for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Table 17 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Table 18 Subracks and fan trays to the front for the RNBC cabinet . . . . . . . . . . 26Table 19 Subracks for back interface units and cable supporting shelves to the rear
for the RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Table 20 Back interface unit for MX1G6/-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 21 Back interface unit for NP8S1-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 22 Installation set EQIS216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 23 Grounding sets for RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 24 Panel brackets for cabinet EC216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 25 Connector Panel for Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . 29Table 26 Rubber covers for RJ-45 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 27 Functional units, plug-in units, and memory modules of the RNBC . . . 31Table 28 Marking strips for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Table 29 Stickers for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d85d4Confidential
DN0938767 7
Equipment Lists for RNC2600 Summary of changes
Id:0900d805808d8b07Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes between Issues 02A (2011-06-09, RU30) and 02B (2012-02-09, RU30)Description part in this document is updated.
Introduction (1)
• Chapter title is changed from About Equipment Lists for RNC2600 to Introduction.
Setting modules (2.1)
• Table 9 Setting modules is updated.
Changes between Issues 02 (2010-12-23, WCDMA RAN RU30) and 02A (2011-06-9, WCDMA RAN RU30)
Cover plates5 (2.1.9)
• SHIM25 is replaced by SHIM25L.
L3 Data collector mechanical set for RNC2600 RNAC (2.1.10)
• Table 13 Rubber covers for RJ-45 connectors is updated.
Back interface unit for NPS1P (3.1.4)
• This chpater is new.
L3 Data collector mechanical set for RNC2600 RNBC (3.1.7)
• Table 25 Rubber covers for RJ-45 connectors is updated.
Changes between issue 1-0 and 02RNAC and RNBC cabinet mechanics are updated.
Cover plates table is added in RNAC cabinet chapter.
RNAC and RNBC configuration are updated.
CCP1D-A, HDS-C and ESA40 related information is added.
Chapter 2.1.10 L3 Data collector mechanical set for RNC2600 RNAC is added.
Chapter 3.1.6 L3 Data collector mechanical set for RNC2600 RNBC is added.
8 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b09Confidential
Introduction
1 IntroductionEquipment Lists for RNC2600 provides information of cabinet mechanics, subracks, and plug-in units installed in the RNAC and RNBC cabinets in new deliveries of RNC2600.
RNC2600 offers three capacity steps:
• Section RNAC cabinet lists the equipment for the RNC2600 capacity step 1. • Section RNBC cabinet lists the equipment for the RNC2600 capacity steps 2-3.
1.1 Related documentsCable ListsDetailed information on cabling and individual cables can be found in Cable Lists for RNC2600.
Engineering DescriptionBasic information on the equipment, hardware configurations and site planning can be found in WCDMA RNC Engineering Description.
Installation ManualDetailed information on the installation of the hardware can be found in Installing the MGW and RNC.
Cabinet Interfaces and CablingDetailed information on the cabinets' external interfaces and cables can be found in Cabinet Interfaces and External Cables of MGW and RNC.
1.2 Notations used in equipment listsThe equipment lists contain the columns shown in the figure below, with their contents described in the list which follows.
DN0938767 9
Equipment Lists for RNC2600 Introduction
Id:0900d805808d8b09Confidential
Figure 1 Notations used in the equipment lists
The positions are presented in the form of a table. The figure shows only one table type, but tables can have the following columns:
• Side indicates the side on which the unit in question is equipped. (F = front, B = back) • Mounting hole no. indicates the number of the mounting hole used for the installation
of the particular unit. • Subrack indicates the subrack position of a specific unit. • Position shows the coordinates inside the rack and the number of the slot in the car-
tridge. • ID (Identification) shows the identification code of the cabinet, cartridge, plug-in unit,
or accessory. • Name shows the abbreviated name of the hardware product for the identification
code in the previous column. • PIU indicates the name of the plug-in unit in question.
IPA2800 RNC / MGW cabinet,
front view
DN05158674
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
38
SUBRACK 3
front view
Plug-in unit position number
1
SUBRACK 1
SUBRACK 2
SUBRACK 3
SUBRACK 4
Position ID Name FU Notes
F01 C105546 CDSP-C DMCU 4
F02 C105546 CDSP-C DMCU 5
F03 C109093 ICSU 4
1
Subrack 3
CCP18-A Mounted
2GB memory
included
10 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b09Confidential
Introduction
• FU (Functional Unit) shows the name and index number of the functional unit equipped into the cartridge in this particular position.
• Use shows the name and number of the functional unit, which contains the plug-in units listed below and equipped in this cartridge position.
• Notes column includes additional information.
When two or more different hardware products can be equipped in the same position, the identification code and name of each type is given.
DN0938767 11
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
2 RNAC cabinetThis chapter lists all the equipment for the RNAC cabinet.
2.1 RNAC cabinet
2.1.1 Subracks and fan trays to the front
2.1.2 Subracks for back interface units, panels, and cable supporting shelves to the rear
Equipping Side ID Name Use
C109740 EC216 Cabinet
F C111704 D216 Cabinet EC216 door
B C111704 D216 Cabinet EC216 door
F C110052 CPD120-A Power distribution and fuse unit
F C110052 CPD120-A Power distribution and fuse unit
F C110505 CAIND-A Cabinet Alarm indicator
C110076 SCP216 Side cover plate
C110076 SCP216 Side cover plate
Table 1 RNAC cabinet
Side Mounting hole no.
ID Name Use
F 61 C109979 SRA3 Subrack
F 55 C109730 FTRA-B Fan tray
F 43 C109979 SRA3 Subrack
F 37 C109730 FTRA-B Fan tray
F 25 C109979 SRA3 Subrack
F 19 C109730 FTRA-B Fan tray
F 7 C109979 SRA3 Subrack
F 1 C109730 FTRA-B Fan tray
Table 2 Subracks and fan trays to the front for the RNAC
Side Mounting hole no./ Position
ID Name Use Notes
B 61 C110568 SRBI-C Subrack for back interface units
Table 3 Subracks for back interfaces, connector panels, and cable supporting shelves to the rear for the RNAC
12 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
B 58 C110730 CS216-A Cable supporting shelf
B 58 C110551 CPSY-A Connector panel for synchronisation
B 58 C110747 CPSY-B Connector panel for synchronisation
B 43 C110568 SRBI-C Subrack for back interface units
B 40 C110730 CS216-A Cable supporting shelf
B 40 C110487 CPAL-A Connector panel for alarm
B 22 C105864 CS216-A Cable supporting shelf
B 25 C110568 SRBI-C Subrack for back interface units
B 7 C110568 SRBI-C Subrack for back interface units
B 4 C105864 CS216-A Cable supporting shelf
Side Mounting hole no./ Position
ID Name Use Notes
Table 3 Subracks for back interfaces, connector panels, and cable supporting shelves to the rear for the RNAC (Cont.)
DN0938767 13
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels
2.1.3 Back interface unit for SF20/SFCO-A
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
CPSY-A
CPAL-A
CPSY-B
DN05160803
Position ID Name Use Notes
Subrack 1
2 C109973 BISFA Back interface unit for SF20/SFCO-A
Table 4 Back interface unit for SF20/SFCO-A
14 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
2.1.4 Back interface unit for SF20/SFA20
2.1.5 Back interface unit for MX1G6/-A
Subrack 2
2 C109973 BISFA Back interface unit for SF20/SFCO-A
Note: All panels are installed after (all) cables have been connected.
Position ID Name Use Notes
Table 4 Back interface unit for SF20/SFCO-A (Cont.)
Position ID Name Use Notes
Subrack 1
1 C109976 BISFD Back interface unit for SF20/SFA20
Subrack 2
1 C109976 BISFD Back interface unit for SF20/SFA20
Note: All panels are installed after (all) cables have been connected.
Table 5 Back interface unit for SF20/SFA20
Position ID Name Use Notes
Subrack 1
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 2
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 3
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 4
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Note: All panels are installed after (all) cables have been connected.
Table 6 Back interface unit for MX1G6/-A
DN0938767 15
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
2.1.6 Back interface unit for NP2GE-B/NP8S1-B
2.1.7 Installation set
The EQIK216 installation set contains the following items:
• washers • static control wrist strap • screws • locking pegs • cable ties
2.1.8 Setting modules
Position ID Name Use Notes
Subrack 1
17 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
18 C109975 BISFC Back interface unit for NP2GE-B 1)
Subrack 2
17 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
18 C109975 BISFC Back interface unit for NP2GE-B 2)
Subrack 3
15 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
17 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
Subrack 4
15 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
17 C109975 BISFC Back interface unit for NP2GE-B/NP8S1-B
1) Default: connected when NPGE/NPGEP 2 is in the configuration. Optional: removed when NPS1/NPS1P 0 is in the configuration.
2) Default: connected when NPGE/NPGEP 3 is in the configuration. Optional: removed when NPS1/NPS1P 1 is in the configuration.
Note: All panels are installed after (all) cables have been connected.
Table 7 Back interface unit for NP2GE-B/NP8S1-B
ID Name Use
C110720 EQIK216 Installation set for cabinet A
Table 8 Installation set EQIK216
Position ID Name Use Notes
1.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module
Table 9 Setting modules
16 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
2.1.9 Cover plates
2.1.10 L3 Data collector mechanical set for RNC2600 RNAC
1.0B 5.1U C108585 ADMOD01 SWU Subrack address setting module
2.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module
2.0B 5.1U C108689 ADMOD02 SWU Subrack address setting module
Position ID Name Use Notes
Table 9 Setting modules (Cont.)
Position ID Name Use Notes
F06 C73384 SHIM25 Cover plate for empty slots Subrack 1
F15 C112694 SHIM25L Cover plate for empty slots Subrack 1
F15 C112694 SHIM25L Cover plate for empty slots Subrack 2
Table 10 Cover plates
Quantity ID Name Use Notes
1 C112559 PBEC216 Panel bracket for EC216
Table 11 Panel brackets for cabinet EC216
Quantity ID Name Use Notes
1 C100740 CPLAN-A CPLAN-A Connector Panel For Ethernet Interface
Table 12 Connector panel for Ethernet interface
Quantity ID Name Notes
32 5466465 RJ45 DUST CAP
Table 13 Rubber covers for RJ-45 connectors
DN0938767 17
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
2.2 RNAC functional units and plug-in units
Figure 3 Functional units of the RNAC cabinet, capacity step 1
Equipping rulesAs a default, the cabinets are delivered equipped, but use these instructions if equipping is needed.
18 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
Capacity step 1 (RNC2600/step 1) includes all RNAC subracks. Capacity step 2 (RNC2600/step 2) includes also RNBC subracks 1 and 2. Capacity step 3 (RNC2600/step 3) includes all RNAC and RNBC subracks. All units are equipped in index order, starting from the lowest index.
1. Equip all plug-in units for the required capacity step.2. Check which interfaces are included in the delivery and equip the interface plug-in
units in index order, lowest first.a) NPGEP and NPGE units in index order, starting from index 0.b) NPS1P and NPS1 units in index order, starting from index 2. Equipping starts
from NPS1P/NPS1 2 (from RNAC subrack 3).c) In a pure STM-1 interface configuration there are also NPS1P/NPS1 0-1 units
equipped to RNAC subracks 1 and 2. In this case, back interface panels and cablings for NPGEP/NPGE 2-3 must be removed and redundancy cabling between NPS1P 0-1 units must be equipped. Redundancy cabling between NPS1P 0-1 units is provided on cabling shelves.
3. Equip the optional SWU1 unit.4. Install cover plates SHIM25 to empty equipping slots. Install cover plates SHIM25,
COP200 and COP25H to empty RNBC subracks 3 and 4 in RNC2600/step 2 deliv-eries.
5. If CCP1D-A is used for an OMU, the redundant OMU must be CCP1D-A. If CCP1D-A is used for an OMU, the replacement of HDS-B to HDS-C is mandatory and a standalone OMS should be used instead of an integrated OMS.
The following units are ordered separately:
• Optional second SWU (ESA40-A) • Optional NPS1(P) • Optional NPGE(P)
Position ID HW product or plug-in unit name
FU configuration Notes
Subrack 1
F01
F02
C110468 SF20H SFU 0 BISFD at the rear of the cabinet
BISFA at the rear of the cabinet. BISFA is two slots wide (B02-03).
F03 C111943 CCP1D-A ICSU 0 2*2GB memory included
F04 C111943 CCP1D-A RSMU 0 2*2GB memory included
F05 C111417 ESA40-A SWU 0 Cabinet address setting module in backplan: ADMOD01
Subrack address setting module in backplan: ADMOD01
F06 C73384 SHIM25 -
F07 C110830 CDSP-DH DMCU 0
Table 14 Functional units, plug-in units, and memory modules of the RNAC
DN0938767 19
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
F08 C110830 CDSP-DH DMCU 1
F09 C110911 MX1G6/-A MXU 0 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 1 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 2
F13 C110830 CDSP-DH DMCU 3
F14 C111977 HDS-C WDU 0 (OMU)
F15 C73384 SHIM25L -
F16 C111943 CCP1D-A OMU 0 2*2GB memory included
F17 C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 0
NPS1(P) 0
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
NPGE(P) 2 is only equipped with NPGE(P) 0.
F18 C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 2
NPS1(P) 0
F19 C111574 TSS3-A TBU 0
F38 C71700 TBUF TBU 1
Subrack 2
F01
F02
C100580 SF20H SFU 1 BISFD at the rear of the cabinet
BISFA at the rear of the cabinet. BISFA is two slots wide (B02-03).
F03 C111943 CCP1D-A ICSU 1 2*2GB memory included
F04 C111943 CCP1D-A RSMU 1 2*2GB memory included
F05 C111417 ESA-A SWU 1
F06 C111943 CCP1D-A ICSU 2 2*2GB memory included
F07 C110830 CDSP-DH DMCU 4
F08 C110830 CDSP-DH DMCU 5
F09 C110911 MX1G6/-A MXU 2 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 3 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 6
F13 C110830 CDSP-DH DMCU 7
F14 C111977 HDS-C WDU 1(OMU)
F15 C73384 SHIM25L -
F16 C111943 CCP1D-A OMU 1 2*2GB memory included
Position ID HW product or plug-in unit name
FU configuration Notes
Table 14 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
20 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
F17 C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 1
NPS1(P) 1
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
NPGE(P) 3 is only equipped with NPGE(P) 1.
F18 C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 3
NPS1(P) 1
F19 C71700 TBUF TBU 0
F38 C111574 TSS3-A TBU 1
Subrack 3
F01 C111943 CCP1D-A ICSU 3 2*2GB memory included
F02 C111943 CCP1D-A ICSU 4 2*2GB memory included
F03 C111943 CCP1D-A ICSU 5 2*2GB memory included
F04 C111943 CCP1D-A ICSU 6 2*2GB memory included
F05 C100880 EHAT EHU
F06 C110830 CDSP-DH DMCU 8
F07 C110830 CDSP-DH DMCU 9
F08 C110830 CDSP-DH DMCU 10
F09 C110911 MX1G6/-A MXU 4 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 5 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 11
F13 C110830 CDSP-DH DMCU 12
F14 C111943 CCP1D-A ICSU 7 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGEP/NPGE 4
NPS1P/NPS1 2
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGEP/NPGE 6
NPS1P/NPS1 4
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 4
F01 C111943 CCP1D-A ICSU 8 2*2GB memory included
F02 C111943 CCP1D-A ICSU 9 2*2GB memory included
F03 C111943 CCP1D-A ICSU 10 2*2GB memory included
F04 C111943 CCP1D-A ICSU 11 2*2GB memory included
F05 C111943 CCP1D-A ICSU 12 2*2GB memory included
F06 C110830 CDSP-DH DMCU 13
F07 C110830 CDSP-DH DMCU 14
Position ID HW product or plug-in unit name
FU configuration Notes
Table 14 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
DN0938767 21
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
2.3 RNAC cabinet stickers and marking strips
2.3.1 Marking strips
2.3.2 Stickers
F08 C110830 CDSP-DH DMCU 15
F09 C110911 MX1G6/-A MXU 6 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 7 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 16
F13 C110830 CDSP-DH DMCU 17
F14 C111943 CCP1D-A ICSU 13 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 5
NPS1(P) 3
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 7
NPS1(P) 5
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Position ID HW product or plug-in unit name
FU configuration Notes
Table 14 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
Position Name Use Note
F1 RNAC SRA3 Marking strip for subrack 1
F2 RNAC SRA3 Marking strip for subrack 2
F3 RNAC SRA3 Marking strip for subrack 3
F4 RNAC SRA3 Marking strip for subrack 4
Table 15 Marking strips for the RNAC
Position Name Use Notes
F Name sticker RNAC Network Element Sticker (front side - window)
B Name sticker RNAC Network Element Sticker (rear side)
F Identifier sticker Subrack position number sticker
F ESD sticker Each subrack 4 pcs
T Note sticker Top of the cabinet
Table 16 Stickers for the RNAC
22 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
F Earthing sticker 4 pcs
T B: HDD-0 OMS Optional choice after RN5.0
T A: WDU-0 OMU
T B: HDD-1 OMS Optional choice after RN5.0
T A: WDU-1 OMU
T UB 1 sticker Power sticker
T UB 2 sticker Power sticker
Position Name Use Notes
Table 16 Stickers for the RNAC (Cont.)
DN0938767 23
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
Figure 4 IPA2800 EC216 cabinet; the stickers in the figure, except the network element name and marking strips,are attached to all cabinets
24 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0bConfidential
RNAC cabinet
Figure 5 IPA2800 EC216 cabinet, stickers equipped on delivery
Guidelines for product collection and safe disposal of the equipment are indicated on a sticker placed on the equipment. The sticker is shown in the figure below.
DN0938767 25
Equipment Lists for RNC2600 RNAC cabinet
Id:0900d805808d8b0bConfidential
Figure 6 Product collection and disposal within the European Union
g Stickers attached on delivery include: ESD caution sticker, LOT ID label, Warning sticker about sharp edges, Earth Bonding Point sticker, WEEE sticker, and Equipping sticker.
26 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0dConfidential
RNBC cabinet
3 RNBC cabinetThis chapter lists all the equipment for the RNBC cabinet.
3.1 RNBC cabinet
3.1.1 Subracks and fan trays to the front
3.1.2 Subracks for back interface units and cable supporting shelves to the rear
Equipping Side
ID Name Use
C109740 EC216 Cabinet
F C111704 D216 Cabinet EC216 door
B C111704 D216 Cabinet EC216 door
F C110052 CPD120-A Power distribution and fuse unit
F C110052 CPD120-A Power distribution and fuse unit
Table 17 RNBC cabinet
Equipping Side
Mounting hole no.
ID Name Use
F 61 C109979 SRA3 Subrack
F 55 C109730 FTRA-B Fan tray
F 43 C109979 SRA3 Subrack
F 37 C109730 FTRA-B Fan tray
F 25 C109979 SRA3 Subrack
F 19 C109730 FTRA-B Fan tray
F 7 C109979 SRA3 Subrack
F 1 C109730 FTRA-B Fan tray
Table 18 Subracks and fan trays to the front for the RNBC cabinet
Side Mounting hole no.
ID Name Use
B 61 C110568 SRBI-C Subrack for back interface units
B 58 C105864 CS186-B Cable supporting shelf
B 43 C110568 SRBI-C Subrack for back interface units
B 40 C105864 CS186-B Cable supporting shelf
Table 19 Subracks for back interface units and cable supporting shelves to the rear for the RNBC cabinet
DN0938767 27
Equipment Lists for RNC2600 RNBC cabinet
Id:0900d805808d8b0dConfidential
3.1.3 Back interface unit for MX1G6/-A
3.1.4 Back interface unit for NP8S1-B
B 25 C110568 SRBI-C Subrack for back interface units
B 22 C105864 CS186-B Cable supporting shelf
B 7 C110568 SRBI-C Subrack for back interface units
B 4 C105864 CS186-B Cable supporting shelf
Side Mounting hole no.
ID Name Use
Table 19 Subracks for back interface units and cable supporting shelves to the rear for the RNBC cabinet (Cont.)
Position ID Name Use Notes
Subrack 1
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 2
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 3
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Subrack 4
9 C109974 BISFB Back interface unit for MX1G6/-A
11 C109974 BISFB Back interface unit for MX1G6/-A
Note: All panels are installed after (all) cables have been connected.
Table 20 Back interface unit for MX1G6/-A
Position ID Name Use Notes
Subrack 1
15 C109975 BISFC Back interface unit for NP8S1-B 1)
17 C109975 BISFC Back interface unit for NP8S1-B 1)
Subrack 2
15 C109975 BISFC Back interface unit for NP8S1-B 1)
17 C109975 BISFC Back interface unit for NP8S1-B 1)
Subrack 3
15 C109975 BISFC Back interface unit for NP8S1-B 1)
Table 21 Back interface unit for NP8S1-B
28 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0dConfidential
RNBC cabinet
3.1.5 Installation set
The EQIS216 installation set contains the following items:
• washers • static control wrist strap • screws • locking pegs • cable ties
3.1.6 Grounding setThe grounding cables between RNAC and RNBC cabinets need to be installed at the site.
The grounding set contains:
• 4 pcs grounding cables • washers • screws
17 C109975 BISFC Back interface unit for NP8S1-B 1)
Subrack 4
15 C109975 BISFC Back interface unit for NP8S1-B 1)
17 C109975 BISFC Back interface unit for NP8S1-B 1)
1) Don’t install BISFC back interface card before inter-cabinet cables are connected.
Position ID Name Use Notes
Table 21 Back interface unit for NP8S1-B (Cont.)
ID Name Use
C110721 EQIS216 Installation set for cabinet B
Table 22 Installation set EQIS216
Side Mounting hole no.
ID Name Use Notes
B 61, 43, 25, 7
C107156 Grounding set Grounding RNAC to RNBC
EC216 to EC216
Table 23 Grounding sets for RNBC
DN0938767 29
Equipment Lists for RNC2600 RNBC cabinet
Id:0900d805808d8b0dConfidential
Figure 7 Grounding between RNAC and RNBC
3.1.7 L3 Data collector mechanical set for RNC2600 RNBC
REAR SIDE OF CABINET DN0644085
EC216
EC216
Quantity ID Name Use Notes
1 C112559 PBEC216 Panel bracket for EC216
Table 24 Panel brackets for cabinet EC216
Quantity ID Name Use Notes
1 C100740 CPLAN-A CPLAN-A Connector Panel For Ethernet Interface
Table 25 Connector Panel for Ethernet Interface
Quantity ID Name Notes
32 5466465 RJ45 DUST CAP
Table 26 Rubber covers for RJ-45 connectors
30 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0dConfidential
RNBC cabinet
3.2 RNBC functional units and plug-in units
Figure 8 Functional units of the RNBC cabinet, capacity steps 2 and 3
Equipping rulesAs a default, the cabinets are delivered equipped, but use these instructions if equipping is needed.
DN0938767 31
Equipment Lists for RNC2600 RNBC cabinet
Id:0900d805808d8b0dConfidential
Subracks 1–2 of the RNBC cabinet form capacity step 2 (RNC2600/step 2) and subracks 3–4 form capacity step 3 (RNC2600/step3). NPS1(P)/NPGE(P) units are ordered separately as needed.
All units are equipped in index order, starting from the lowest index.
1. Equip all plug-in units for the required capacity step.2. Check which interfaces are included in the delivery and equip the interface plug-in
units in index order, lowest first.a) NPGEP and NPGE units in index order, starting from index 0.b) NPS1P and NPS1 units in index order, starting from index 2. Equipping starts
from NPS1P/NPS1 2 (from RNAC subrack 3).c) In a pure STM-1 interface configuration there are also NPS1P/NPS1 0-1 units
equipped to RNAC subracks 1 and 2. In this case, back interface panels and cabling for NPGEP/NPGE 2-3 must be removed and redundancy cabling between NPS1P 0-1 units must be equipped. Redundancy cabling between NPS1P 0-1 units is provided on cabling shelves.
3. Equip the optional SWU unit.4. Install cover plates SHIM25, COP200 and COP25H to empty RNBC subracks 3 and
4 in RNC2600/step 2 deliveries.
Position ID HW product or plug-in unit name
FU configuration Notes
Subrack 1
F01 C111943 CCP1D-A ICSU 14 2*2GB memory included
F02 C111943 CCP1D-A ICSU 15 2*2GB memory included
F03 C111943 CCP1D-A ICSU 16 2*2GB memory included
F04 C111943 CCP1D-A ICSU 17 2*2GB memory included
F05 C111943 CCP1D-A ICSU 18 2*2GB memory included
F06 C110830 CDSP-DH DMCU 18
F07 C110830 CDSP-DH DMCU 19
F08 C110830 CDSP-DH DMCU 20
F09 C110911 MX1G6/-A MXU 8 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 9 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 21
F13 C110830 CDSP-DH DMCU 22
F14 C111943 CCP1D-A ICSU 19 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 8
NPS1(P) 6
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 10
NPS1(P) 8
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
Table 27 Functional units, plug-in units, and memory modules of the RNBC
32 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0dConfidential
RNBC cabinet
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 2
F01 C111943 CCP1D-A ICSU 20 2*2GB memory included
F02 C111943 CCP1D-A ICSU 21 2*2GB memory included
F03 C111943 CCP1D-A ICSU 22 2*2GB memory included
F04 C111943 CCP1D-A ICSU 23 2*2GB memory included
F05 C111943 CCP1D-A ICSU 24 2*2GB memory included
F06 C110830 CDSP-DH DMCU 23
F07 C110830 CDSP-DH DMCU 24
F08 C110830 CDSP-DH DMCU 25
F09 C110911 MX1G6/-A MXU 10 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 11 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 26
F13 C110830 CDSP-DH DMCU 27
F14 C111943 CCP1D-A ICSU 25 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 9
NPS1(P) 7
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 11
NPS1(P) 9
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F19 C71700 TBUF TBU0
F38 C71700 TBUF TBU 1
Subrack 3
F01 C111943 CCP1D-A ICSU 26 2*2GB memory included
F02 C111943 CCP1D-A ICSU 27 2*2GB memory included
F03 C111943 CCP1D-A ICSU 28 2*2GB memory included
F04 C111943 CCP1D-A ICSU 29 2*2GB memory included
F05 C111943 CCP1D-A ICSU 30 2*2GB memory included
F06 C110830 CDSP-DH DMCU 28
F07 C110830 CDSP-DH DMCU 29
F08 C110830 CDSP-DH DMCU 30
F09 C110911 MX1G6/-A MXU 12 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 13 BISFB at the rear of the cabinet
Position ID HW product or plug-in unit name
FU configuration Notes
Table 27 Functional units, plug-in units, and memory modules of the RNBC (Cont.)
DN0938767 33
Equipment Lists for RNC2600 RNBC cabinet
Id:0900d805808d8b0dConfidential
3.3 RNBC cabinet stickers and marking stripsSee Figures of IPA2800 EC216 cabinet in Section RNAC cabinet stickers and marking strips for the locations of the marking strips and stickers.
F12 C110830 CDSP-DH DMCU 31
F13 C110830 CDSP-DH DMCU 32
F14 C111943 CCP1D-A ICSU 31 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 12
NPS1(P) 10
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 14
NPS1(P) 12
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 4
F01 C111943 CCP1D-A ICSU 32 2*2GB memory included
F02 C111943 CCP1D-A ICSU 33 2*2GB memory included
F03 C111943 CCP1D-A ICSU 34 2*2GB memory included
F04 C111943 CCP1D-A ICSU 35 2*2GB memory included
F05 C111943 CCP1D-A ICSU 36 2*2GB memory included
F06 C110830 CDSP-DH DMCU 33
F07 C110830 CDSP-DH DMCU 34
F08 C110830 CDSP-DH DMCU 35
F09 C110911 MX1G6/-A MXU 14 BISFB at the rear of the cabinet
F10 C109472 PD30 Subrack power
F11 C110911 MX1G6/-A MXU 15 BISFB at the rear of the cabinet
F12 C110830 CDSP-DH DMCU 36
F13 C110830 CDSP-DH DMCU 37
F14 C111943 CCP1D-A ICSU 37 2*2GB memory included
F15
F 16
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 13
NPS1(P) 11
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F17
F 18
C111587
C111323
NP2GE-B
NP8S1-B
NPGE(P) 15
NPS1(P) 13
BISFC at the rear of the cabinet
NP8S1-B is two slots wide
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Position ID HW product or plug-in unit name
FU configuration Notes
Table 27 Functional units, plug-in units, and memory modules of the RNBC (Cont.)
34 DN0938767
Equipment Lists for RNC2600
Id:0900d805808d8b0dConfidential
RNBC cabinet
3.3.1 Marking strips
3.3.2 Stickers
Position Name Use Note
F1 RNBC SRA3 Marking strip for subrack 1
F2 RNBC SRA3 Marking strip for subrack 2
F3 RNBC SRA3 Marking strip for subrack 3
F4 RNBC SRA3 Marking strip for subrack 4
Table 28 Marking strips for the RNBC
Position Name Use Notes
F Name sticker RNBC Network Element Sticker (front side - window)
B Name sticker RNBC Network Element Sticker (rear side)
F Identifier sticker Subrack position number sticker
F ESD sticker Each subrack 4 pcs
T Note sticker Top of the cabinet
F Earthing sticker 4 pcs
T UB 1 sticker Power sticker
T UB 2 sticker Power sticker
Table 29 Stickers for the RNBC