Page 1: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

Catalogue 2011

a Nexans company

Page 2: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

1

01/2

011

While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.

EUROMOLDEuromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of cold-shrinkable terminations and joints from 12 to 42 kV.Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group.

ISO 9001 CertificateSince 1992, Euromold’s commitment to quality is demonstrated by its ISO 9001 certification.

Laboratory accreditationSince June 2000, Euromold’s independent ELAB laboratory obtained the BELAC accreditation no.144-TEST conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards HD 623 and HD 629.

International standardsAll our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4… or country speci-fications. Official certificates, CESI, KEMA, ATEX… prove the conformity of our products. Long duration tests of existing or new products are con-tinuously performed in our test fields.

Nexans Network SolutionsDiv. Euromold

COMPANY PRESENTATION

Page 3: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

2

01/2

011

SEPARABLE CONNECTORSAND BUSHINGS

INTERFACE C

Interface CDimensions according to European CENELEC EN 50180 and 50181 (in mm).

Table of contents400LB - elbow connector430TB - tee connector400TB - tee connector434TB - tee connector440TB - tee connector300PBM - coupling connector430TBM-P2/P3 - dual/triple cable arrangement440PBM - coupling connector434TBM-P2 - dual cable arrangement400AR-3 - equipment bushing400AR-4 - equipment bushing400AR-5 - equipment bushing400AR-6 - equipment bushing400SFR-B - equipment bushing400A-24B - in-air bushing300SA - surge arrester400PB-XSA - surge arrester400TR & 400TR-LB - test rod400TK-400SW installation toolsAccessoriesPossible arrangements

90±0.2

Dia. 46±0.2

Dia. 56±0.2

Dia. 70±0.2

0-0.51.5M16 x 2 - 6H

29min

11min

Dia. 22 min for C1Dia. 32 nominal for C2

Page 4: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

3 01/2

011

Connecting possibilities

CONNECTIONBUSHINGS /ACCESSORIES

CONNECTORS /ACCESSORIES

(K)(M)300PBM/GCoupling connector

300SASurge arrester

dead-endingof equipment (K)(M)400DR-B

Dead-end receptacle

cableearthing

tap-off630/250A

in-linejunction

in-linejunction

(K)400LB/GElbow connector

(K)(M)(P)400TB/GTee connector

(K)(M)(P)440TB/GTee connector

(K)(M)430TB/GTee connector

Equipmentinterface

(K)(M)400AR-3Equipment bushing

400A-24BIn-air bushing

(K)(M)400SOP-BStand-off plug

400GP-BEarthing plug

(K)400RTPAReducing tap plug

(K)(M)440CPConnecting plug

(K)(M)400CP-SCConnecting plug

(K)(M)400SFR-BEquipment bushing

(K)(M)400AR-6Equipment bushing

(K)(M)400AR-4Equipment bushing

(K)(M)400AR-5Equipment bushing

cable toequipment

cableisolation

400PB-XSASurge arrester

(K)(M)440PBM/GCoupling connector

(K)(M)434TB/GTee connector

Page 5: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

4

01/2

011

Specifications and standardsThe 400LB separable connector meets the requirements of CENELEC HD 629.1.

Up to 24 kV - 630 A

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Conductor sizes (mm2)

min max

400LB/G

K400LB/G

12

24

630

630

25

25

300

300

DesignSeparable connector comprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer moulded between the insert and the jacket.4. Type C - 630 A interface as described by CENELEC EN 50180 and 50181.5. Conductor connector (not included in the standard kit).6. Insulating plug.7. Cable reducer.8. Earthing lead.9. Transition contact M10/M16.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

400LBINTERFACE C

ELBOW CONNECTOR

ApplicationSeparable elbow connector designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...).Also connects cable to cable, using the appropriate mating part.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

Technical characteristics ������������ �����������

jacket provides a total safe to touch screen which ensures safety for personnel.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

330 mm

205 mm

9

4

1

5

2

38

7

6

Page 6: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

5

Kit contentsThe complete (K)400LB/G elbow connector kit comprises 3 x the following components:

Ordering instructionsSelect the part numberwhich gives the best centring to the cable core insulation diameter.Add a 'K' for use up to 24 kV.

Orderingpart number

Dia. over core insulation (mm)

min max

3 x 400LB/G-11

3 x 400LB/G-15

3 x 400LB/G-19

3 x 400LB/G-22

3 x 400LB/G-25

3 x 400LB/G-27

12.0

16.0

20.0

23.5

26.5

28.5

17.5

22.0

26.5

31.0

32.5

37.5Example:The copper wire screened cables are 24 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 32.2 mm.Order 3 x K400LB/G-27 elbow connector kit.

Can be suppliedwith cable lugs.

For applicationsoutdoors and in humid climate.

Order: +MWS.

Components can be ordered individually.

For use withcopper tape

screened cables. Order: Kit MT.

For use with Alupe orC 33-226 cables.

Please contact our representative.

For use with fabric tape (graphite) screened cables.

Order additionalsemi-conductive tape

(type TSC).

3 x (K)400LB/G-W(-X)connector kit

Table W

Notes:We do not supply the compression lugs in the standard kit. All types of cable lugs can be used. The lugs must be within the dimensions specified and the palm of the lug must be copper or any equivalent alloy.

Transitioncontact +

screw assembly400LTS

Insulatingplug

400LBPCable reducer

411CA-WConnector housing

(K)400BLB

2 max

Dia. 10.2 or 13

24 max

112 max 135 max

38max

Dia. 36max

10.5max

The kit also comprises silicone grease, field control mastic and installation instructions.

Page 7: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

6

01/2

011

ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors, ...).Also connects cable to cable when using the appropriate mating parts.

Technical characteristics���������� �����������

jacket provides a total safe to touch screen.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

Specifications and standardsThe 430TB separable connector meets the requirements of CENELEC HD 629.1.

Up to 36 kV630 A (800 A)

430TBINTERFACE C

TEE CONNECTOR

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

DesignSeparable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

185 mm

290 mm

(350 mmfor 36 kV)

4 9

6

1

2

3

10

7

5

8

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Current Ir (A)Conductor sizes (mm2)

When installed on an appropriate equipment bushing and when using a copper (-11-2) or a

bolted (-12-5 or -14-5) conductor contact min max

430TB/GK430TB/GM430TB/G

122436

630630630

800800800

353550

300300240

Page 8: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

7

3 x (K)(M)430TB/G-W-X connector kit

When installed on an appropriate equipment

bushing: 800 A continuously

Kit contentsThe complete (K)(M)430TB/G tee connector kit comprises 3 x the following components:

The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart.

Table W

Table X

Connector housing(K)(M)430BT/G

Cable reducer430CA-W

(411CA-Wfor 36 kV)

Clamping screw

430TCS

For use withcopper tape

screened cables. Order: Kit MT.

Orderingpart number

Voltage(Um)(kV)

Dia. over core insulation (mm)

min max

3 x 430TB/G-11-X3 x 430TB/G-16-X3 x 430TB/G-18-X

3 x K430TB/G-11-X3 x K430TB/G-16-X3 x K430TB/G-18-X

3 x M430TB/G-11-X3 x M430TB/G-15-X3 x M430TB/G-19-X3 x M430TB/G-22-X3 x M430TB/G-25-X3 x M430TB/G-27-X

121212

242424

363636363636

12.017.019.0

12.017.019.0

12.016.020.023.526.528.5

17.523.532.6

17.523.532.6

17.522.026.531.032.537.5

Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.

Example:The cable is 24 kV, 150 mm2 compact stranded copper with a diameter over core insulation of 27.5 mm.Order 3 x K430TB/G-18-95.240-14-5 tee connector kit.

Conductorcontact TMBC-X

Conductor contact TBC-X

For use with Alupe orC 33-226 cables.

Please contact our representative.

For use withother cable types.

Please contact our representative.

For applicationsoutdoors and in humid climate.

Order: +MWS.

For use witheasy strip semi-conductive screened cables. Order: Field control mastic

(type MFC).

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

35 35(K)M-10-2 35KM-10-1 35(K)M-11-250 50(K)M-10-2 50(K)M-10-1 50(K)M-11-270 70(K)M-10-2 70(K)M-10-1 70(K)M-11-295 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2300 300(K)M-10-2 – 300(K)M-11-2

16.9

5-14

-5

95.2

40-1

4-5

50.1

50-1

4-5

120.

300-

12-5

16.9

5-14

-5

50.1

50-1

4-5

95.2

40-1

4-5

120.

300-

12-5

Basic insulatingplug

(K)(M)300BIPA +rubber cap

Page 9: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

8

01/2

011

Up to 41.5 kV630 A (800 A)

400TBINTERFACE C

TEE CONNECTOR

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

20.8/36 (41.5) kV

Technical characteristics ������������ �����������

jacket provides a total safe to touch screen which ensures safety for personnel.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors, ...).Also connects cable to cable when using the appropriate mating parts.

DesignSeparable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer. 4. Type C - 630 A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

Specifications and standardsThe 400TB separable connector meets the requirements of CENELEC HD 629.1 S1.

220 mm

350 mm

8

4 9

1

2

3

10

7

56

255 mm

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Current Ir (A)Conductor sizes (mm2)

When installed on an appropriate equipment bushing and when using a copper (-11-2) or a

bolted (-12-5 or -14-5) conductor contact min max

400TB/GK400TB/GM400TB/GP400TB/G

122436

41.5

630630630630

800800800800

35353535

300300240240

Page 10: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

9

For use withcopper tape

screened cables. Order: Kit MT.

For use in potentiallyexplosive atmospheres

(for 12 kV max). Add -/ATEX to part number.

Kit contentsThe complete (K)(M)(P)400TB/G tee connector kit comprises the following components:

Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV, add a 'P' for use up to 41.5 kV.

Orderingpart number

Dia. over core insulation (mm)

min max

400TB/G-11-X400TB/G-15-X400TB/G-19-X400TB/G-22-X400TB/G-25-X400TB/G-27-X

12.0

16.0

20.0

23.5

26.5

28.5

17.5

22.0

26.5

31.0

32.5

37.5

Example:The copper wire screened cable is 36 kV, 150 mm2 stranded copper with a diameter over core insulation of 32.5 mm.Order a M400TB/G-27-150(K)M-11-2 tee connector kit.

Table W

Table X

(K)(M)(P)400TB/G-W-Xconnector kit

Connector housing(K)(M)(P)400BT/G

Clampingscrew

400TCS

Basic insulatingplug

(K)(M)(P)400BIPA+ rubber cap

Cable reducer411CA-W

Conductorcontact TMBC-X

Conductor contact TBC-X

For use withother cable types.

Please contact our representative.

Components can be ordered individually.

For applicationsoutdoors and in humid climate.

Order: +MWS.

When installed on an appropriate equipment

bushing: 800 A continuously

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

35 35(K)M-10-2 35KM-10-1 35(K)M-11-250 50(K)M-10-2 50(K)M-10-1 50(K)M-11-270 70(K)M-10-2 70(K)M-10-1 70(K)M-11-295 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2300 300(K)M-10-2 – 300(K)M-11-2

16.9

5-14

-5

95.2

40-1

4-5

50.1

50-1

4-5

120.

300-

12-5

16.9

5-14

-5

50.1

50-1

4-5

95.2

40-1

4-5

120.

300-

12-5

The kit also comprises silicone grease, field control mastic, installation instructions and crimp chart.

Page 11: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

10

01/2

011

Up to 36 kVUp to 1250 A

434TBINTERFACE C

TEE CONNECTOR

Technical characteristics ������������ �����������

jacket provides a total safe to touch screen which ensures safety for personnel.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors, ...).Also connects cable to cable when using the appropriate mating parts.

DesignSeparable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

Specifications and standardsThe 434TB separable connector meets the test requirements of CENELEC HD 629.1.

Separable connector

type

VoltageUm(kV)

CurrentIr (A)

When installed on anappropriate equipment bushing

Conductor sizes (mm2)

Cable with reducedcore insulation thickness

Cable with unreducedcore insulation thickness

min max min max434TB/GK434TB/GM434TB/G

122436

up to 1250up to 1250up to 1250

185185185

800800800

185185185

800800630

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

185 mm

84 9

1

2

3

10

7

355 mm

5

6

Page 12: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

11

Kit contentsThe complete (K)(M)434TB/G tee connector kit comprises the following components:

The kit also comprises silicone grease, field control mastic, installation instructions and crimp chart.

Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV.

Example:The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37.0 mm.Order a M434TB/G-32-240(K)M-12-2 tee connector kit.

Orderingpart number

Dia. over core insulation (mm)min max

434TB/G-22-X434TB/G-27-X434TB/G-32-X434TB/G-37-X434TB/G-43-X

23.5

28.5

34.0

39.0

45.5

31.0

37.5

42.5

48.5

56.0

When installed on an appropriate equipment

bushing: 1250 A continuously

For use withcopper tape

screened cables. Order: Kit MT.

Table W

Table X

For use withother cable types.

Please contact our representative.

Components can be ordered individually.

(K)(M)434TB/G-W-Xconnector kit

Connector housing(K)(M)434BT/G

Basic insulatingplug

(K)(M)300BIPA +rubber cap

Cable reducer611CA-W

Conductorcontact TMBC-X

Conductor contact TBC-X

For applicationsoutdoors and in humid climate.

Order: +MWS.

Clampingscrew

430TCS

For use with Alupe orC 33-226 cables.

Please contact our representative.

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

185 185(K)M-12-2 185(K)M-12-1

185(K)M-11-2

240 240(K)M-12-2 240(K)M-12-1 240(K)M-11-2

300 300(K)M-12-2 300(K)M-12-1 300(K)M-11-2

400 400(K)M-12-2 400(K)M-12-1 400(K)M-11-2

500 500(K)M-12-2 500(K)M-12-1 500(K)M-11-2

630 630(K)M-12-2 630(K)M-12-1 630(K)M-11-2 –

800 800(K)M-12-2 800(K)M-12-1 – 800(K)M-11-2 –

400.

630-

14-5

Page 13: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

12

01/2

011

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

20.8/36 (41.5) kV

Up to 41.5 kV630 A (1250 A)

440TBINTERFACE C

TEE CONNECTOR

Technical characteristics ������������ �����������

jacket provides a total safe to touch screen which ensures safety for personnel.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors, ...).Also connects cable to cable when using the appropriate mating parts.

DesignSeparable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - 630 A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

Specifications and standardsThe 440TB separable connector meets the requirements of CENELEC HD 629.1.

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

CurrentIr (A)

When installed on anappropriate equipment bushing

Conductor sizes (mm2)

min max440TB/GK440TB/GM440TB/GP440TB/G

122436

41.5

630630630630

1250125012501250

185185185185

630630630630

4 9

1

2

3

10

7

5 8

255 mm

220 mm

355 mm

6

Page 14: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

13

Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV, add a 'P' for use up to 41.5 kV.

Example:The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37.0 mm.Order a M440TB/G-32-240(K)M-12-2 tee connector kit.

Orderingpart number

Dia. over core insulation (mm)

min max

440TB/G-22-X440TB/G-27-X440TB/G-32-X440TB/G-37-X440TB/G-43-X

23.5

28.5

34.0

39.0

45.5

31.0

37.5

42.5

48.5

56.0

When installed on an appropriate equipment

bushing: 1250 A continuously

Table W

Table X

Components can be ordered individually.

Kit contentsThe complete (K)(M)(P)440TB/G tee connector kit comprises the following components:

The kit also comprises silicone grease, field control mastic, installation instructions and crimp chart.

(K)(M)(P)440TB/G-W-Xconnector kit

Connector housing(K)(M)(P)440BT/G

Clampingscrew

430TCSCable reducer

611CA-W

Conductorcontact TMBC-X

Conductor contact TBC-X

Basic insulatingplug

(K)(M)(P)400BIPA+ rubber cap

For use withcopper tape

screened cables. Order: Kit MT.

For use in potentiallyexplosive atmospheres

(for 12 kV max). Add -/ATEX to part number.

For use withother cable types.

Please contact our representative.

For applicationsoutdoors and in humid climate.

Order: +MWS.

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

185

240

300

400

500

630

185(K)M-12-2

240(K)M-12-2

300(K)M-12-2

400(K)M-12-2

500(K)M-12-2

185KM-12-1

240KM-12-1

300KM-12-1

400KM-12-1

500KM-12-1

630KM-12-1

185(K)M-11-2

240(K)M-11-2

300(K)M-11-2

400(K)M-11-2

500(K)M-11-2

630(K)M-11-2

400.

630-

14-5

Page 15: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

14

01/2

011

ApplicationSeparable coupling connector (bolted type) for dual cable arrangement. It has been designed to be used with 430TB separable Tee connector.

Technical characteristics���������� �����������

jacket provides a total safe to touch screen.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

Up to 36 kV630 A (1250 A)

300PBMCOUPLING CONNECTOR

FOR 430TB/G

Specifications and standardsThe 300PBM coupling connector meets the requirements of CENELECHD 629.1.

Design 1. Interface designed to fit 430TB connector. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. Conductor connector (hexagonal crimping, deep indent crimping or bolted). 9. Cable reducer. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

290 mm(350 mmfor 36 kV)

105 mm

300PBMcouplingconnector

290 mm

1

2

8

3

4

5

9

7

6

10

430TBconnector

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Current Ir (A)Conductor sizes (mm2)

When installed on an appropriate equipment bushing and when using a copper (-11-2) or a

bolted (-12-5 or -14-5) conductor contact min max

300PBM/GK300PBM/GM300PBM/G

122436

630630630

125012501250

353550

300300240

Page 16: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

15

Kit contentsThe complete (K)(M)300PBM/G coupling connector kit comprises 3 x the following components:

The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart.

For use withcopper tape

screened cables. Order: Kit MT.

For use witheasy strip semi-conductive screened cables. Order: Field control mastic

(type MFC).

For use with copperwire screened cables.

No earthingdevice is

necessary.

For use withother cable types.

Please contact our representative.

For outdoorapplications.

Order: +MWS.

Connector housing(K)(M)300BP/G

For use with fabric tape (graphite) screened cables.

Order additionalsemi-conductive tape

(type TSC).

Contact rod 300PB-CR

3 x (K)(M)300PBM/G-W-X coupling connector kit

Cable reducer430CA-W

(411CA-Wfor 36 kV)

Conductorcontact TMBC-X

Conductor contact TBC-X

Table W

Table X

Orderingpart number

Voltage(Um)(kV)

Dia. over core insulation (mm)

min max

3 x 300PBM/G-11-X3 x 300PBM/G-16-X3 x 300PBM/G-18-X

3 x K300PBM/G-11-X3 x K300PBM/G-16-X3 x K300PBM/G-18-X

3 x M300PBM/G-11-X3 x M300PBM/G-15-X3 x M300PBM/G-19-X3 x M300PBM/G-22-X3 x M300PBM/G-25-X3 x M300PBM/G-27-X

121212

242424

363636363636

12.017.019.0

12.017.019.0

12.016.020.023.526.528.5

17.523.532.6

17.523.532.6

17.522.026.531.032.537.5

Ordering instructionsTo order the coupling connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.

Example:The cable is 24 kV, 150 mm2 compact stranded copper with a diameter over core insulation of 27.5 mm.Order 3 x K300PBM/G-18-95.240-14-5 coupling connector kit.

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

35 35(K)M-10-2 35KM-10-1 35(K)M-11-250 50(K)M-10-2 50(K)M-10-1 50(K)M-11-270 70(K)M-10-2 70(K)M-10-1 70(K)M-11-295 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2300 300(K)M-10-2 – 300(K)M-11-2

16.9

5-14

-5

95.2

40-1

4-5

50.1

50-1

4-5

120.

300-

12-5

16.9

5-14

-5

50.1

50-1

4-5

95.2

40-1

4-5

120.

300-

12-5

Page 17: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

16

01/2

011

ApplicationSeparable connectors (bolted type) for dual (P2) and triple (P3) cable arrangements.

Technical characteristics���������� �����������

jacket provides a total safe to touch screen.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

Specifications and standardsThe 430TBM-P2/P3 connectors meet the requirements of CENELEC HD 629.1.

Up to 36 kV630 A (1250 A)

Design 1. Type C interface as described by CENELEC EN 50180 and 50181. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. Conductor connector. 9. Cable reducer. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

430TBM-P2/P3DUAL/TRIPLE CABLE ARRANGEMENT

FOR 430TB CONNECTOR

Non-sizesensitive:290 mm

Sizesensitive:350 mm

105 mm

430TBMconnector

300PBMcouplingconnector

290 mm

1 2

8

3

4

5

9

7

6

10

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Current Ir (A)Conductor sizes (mm2)

When installed on an appropriate equipment bushing and when using a copper (-11-2) or a

bolted (-12-5 or -14-5) conductor contact min max

430TBM-P2/P3K430TBM-P2/P3M430TBM-P2/P3

122436

630630630

125012501250

353550

300300240

Page 18: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

17

Kit contentsThe complete (K)(M)430TBM-P2 connector kit comprises 3 x the following components:

Ordering instructionsTo order the separable connectors for dual cable arrangement, use the tables beside to substitute for W and X in the formula:3 x 430TBM-P2-W-X,for use up to 12 kV.Add a 'K' for use up to 24 kV:3 x K430TBM-P2-W-X.Add an 'M' for use up to 36 kV:3 x M430TBM-P2-W-X.

For triple cable arrangement:3 x 430TBM-P3-W-X,for use up to 12 kV.Add a 'K' for use up to 24 kV:3 x K430TBM-P3-W-X.Add an 'M' for use up to 36 kV:3 x M430TBM-P3-W-X.

Example:The two cables are 24 kV, 150 mm2 stranded aluminium with a diameter over core insulation of 27.5 mm.Order 3 x K430TBM-P2-22-150(K)M-10-2.

Table W

Dia. over coreinsulation (mm) W

min max

12.0

16.0

20.0

23.5

26.5

28.5

17.5

22.0

26.5

31.0

32.5

37.5

11

15

19

22

25

27

1. From table W: select the symbol which gives the best centring of your core insulation diameter.

2. From table X: according to your conductor size and type, select the designation which completes the part number.

The complete (K)(M)430TBM-P3 connector kit comprises 3 x the following components:

In mm.

Table X

When installed on an appropriate equipment

bushing: 1250 A continuously

For use withother cable types.

Please contact our representative.

For use withcopper tape

screened cables. Order: Kit MT.

For use with Alupe orC 33-226 cables.

Please contact our representative.

For applicationsoutdoors and in humid climate.

Order: +MWS.

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

35 35(K)M-10-2 35KM-10-1 35(K)M-11-250 50(K)M-10-2 50(K)M-10-1 50(K)M-11-270 70(K)M-10-2 70(K)M-10-1 70(K)M-11-295 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2300 300(K)M-10-2 – 300(K)M-11-2

16.9

5-14

-5

95.2

40-1

4-5

50.1

50-1

4-5

120.

300-

12-5

16.9

5-14

-5

50.1

50-1

4-5

95.2

40-1

4-5

120.

300-

12-5

For use witheasy strip semi-conductive screened cables. Order: Field control mastic

(type MFC).

110 105

430TB teeconnector

300PBMcouplingconnector

290

300BIPAbasicinsulatingplug

300BIPAbasicinsulatingplug

300PBMcouplingconnectors

430TB teeconnector

Page 19: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

18

01/2

011

ApplicationSeparable coupling connector (bolted type) for dual cable arrangement. It has been designed to be used with 440TB separable Tee connector.

Technical characteristics���������� �����������

jacket provides a total safe to touch screen.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

Up to 36 kV630 A (1250 A)

440PBMCOUPLING CONNECTOR

FOR 440TB

Specifications and standardsThe 440PBM coupling connector meets the requirements of CENELECHD 629.1.

Design 1. Interface designed to fit 440TB connector. 2. Bus for 440PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug. 8. Conductor connector (hexagonal crimping, deep indent crimping or bolted). 9. Cable reducer. 10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

CurrentIr (A)

When installed on anappropriate equipment bushing

Conductor sizes (mm2)

min max

440PBM/GK440PBM/GM440PBM/G

122436

630630630

125012501250

185185185

630630630

400 mm

155 mm

440TBconnector

410 mm

440PBMcouplingconnector

1

2

8

3

4

5

9

7

6

10

Page 20: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

19

Kit contentsThe complete(K)(M)440PBM/G coupling connector kit comprises 3 x the following components:

The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart.

For use withcopper tape

screened cables. Order: Kit MT.

For use witheasy strip semi-conductive screened cables. Order: Field control mastic

(type MFC).

For use with copperwire screened cables.

No earthingdevice is

necessary.

For use withother cable types.

Please contact our representative.

For outdoorapplications.

Order: +MWS.

Connector housing(K)(M)440BP/G

For use with fabric tape (graphite) screened cables.

Order additionalsemi-conductive tape

(type TSC).

3 x (K)(M)440PBM/G-W-X coupling connector kit

Conductorcontact TMBC-X

Conductor contact TBC-X

Ordering instructionsTo order the coupling connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV.

Example:The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37.0 mm.Order 3 x M440PBM/G-32-240(K)M-12-2 coupling connector kit.

Orderingpart number

Dia. over core insulation (mm)

min max

3 x 440PBM/G-22-X3 x 440PBM/G-27-X3 x 440PBM/G-32-X3 x 440PBM/G-37-X3 x 440PBM/G-43-X

23.5

28.5

34.0

39.0

45.5

31.0

37.5

42.5

48.5

56.0

Table W

Contact rod 440PB-CR

+ M16 studCable reducer

611CA-W

Table X

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

185

240

300

400

500

630

185(K)M-12-2

240(K)M-12-2

300(K)M-12-2

400(K)M-12-2

500(K)M-12-2

185KM-12-1

240KM-12-1

300KM-12-1

400KM-12-1

500KM-12-1

630KM-12-1

185(K)M-11-2

240(K)M-11-2

300(K)M-11-2

400(K)M-11-2

500(K)M-11-2

630(K)M-11-2

400.

630-

14-5

Page 21: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

20

01/2

011

ApplicationSeparable connectors (boltedtype) for dual cable arrangements.

Technical characteristics���������� �����������

jacket provides a total safe to touch screen.

���������������������������tested for AC withstand and partial discharge prior to leaving the factory.

Specifications and standardsThe 434TBM-P2 connectors meet the requirements of CENELEC HD 629.1.

Up to 36 kV630 A (1250 A)

Design 1. Type C interface as described by CENELEC EN 50180 and 50181. 2. Bus for 440PB. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. Conductor connector. 9. Cable reducer. 10. Earthing lead. 11. Threaded M16 stud for the equipment bushing.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

434TBM-P2DUAL CABLE ARRANGEMENT FOR

434TB CONNECTOR

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Current Ir (A)Conductor sizes (mm2)

When installed on an appropriate equipment bushing and when using a copper (-11-2) or a

bolted (-12-5 or -14-5) conductor contact min max

434TBM-P2K434TBM-P2M434TBM-P2

122436

630630630

125012501250

185185185

630630630

155 mm

345 mm

18

3

4

5

9

7

6

2

440PBcoupling

connector434TBconnector

11

10

Page 22: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

21

Kit contentsThe complete (K)(M)434TBM-P2 connector kit comprises 3 x the following components:

In mm.

When installed on an appropriate equipment

bushing: 1250 A continuously

For use withother cable types.

Please contact our representative.

For use withcopper tape

screened cables. Order: Kit MT.

For use with Alupe orC 33-226 cables.

Please contact our representative.

For applicationsoutdoors and in humid climate.

Order: +MWS.

For use witheasy strip semi-conductive screened cables. Order: Field control mastic

(type MFC).

Ordering instructionsTo order the coupling connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, add an 'M' for use up to 36 kV.

Example:The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37.0 mm.Order 3 x M434TBM-P2-32-240(K)M-12-2 coupling connector kit.

Orderingpart number

Dia. over core insulation (mm)

min max

3 x 434TBM-P2-22-X3 x 434TBM-P2-27-X3 x 434TBM-P2-32-X3 x 434TBM-P2-37-X3 x 434TBM-P2-43-X

23.5

28.5

34.0

39.0

45.5

31.0

37.5

42.5

48.5

56.0

Table W

Table X

110 155

440PBcouplingconnector

434TBteeconnector

300BIPAbasicinsulatingplug

345

Conduc-tor sizes (mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

BoltedDIN

hexagonalBolted

185

240

300

400

500

630

185(K)M-12-2

240(K)M-12-2

300(K)M-12-2

400(K)M-12-2

500(K)M-12-2

185KM-12-1

240KM-12-1

300KM-12-1

400KM-12-1

500KM-12-1

630KM-12-1

185(K)M-11-2

240(K)M-11-2

300(K)M-11-2

400(K)M-11-2

500(K)M-11-2

630(K)M-11-2

400.

630-

14-5

Page 23: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

22

01/2

011

Up to 36 kV - 630 A

400AR-3INTERFACE C

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

Specifications and standardsThe bolted type equipment bushings 400AR-3 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137.

Ordering instructionsTo order the equipment bushing, specify the type.The bushings can be supplied with an earth jumper (/J).E.g. M400AR-3/J.For use in potentially explosive atmospheres (for 12 kV max), order: 400AR-3/ATEX. Minimum oil level:

-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm

40

Dia. 128

133

144

330

Dia. 88

Dia.25

Dia. 70M16

10

30

In mm.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

400AR-3K400AR-3M400AR-3

122436

630630630

Page 24: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

23

In mm.

FIXINGS FOR EQUIPMENT BUSHINGS

400AR-3/J Bushing

Fixing dimensions standards DIN 42 538German standards.

M10

55

Dia. 140Dia. 90

25

6 fixingstuds

equipmentconnection

fixing studs

bushing interface

equipment

sealing gasket

fixing flangeB DIN 42 538

E DIN 42 538stud clamp

earth jumper

Bushing clamping kitTo order the bushing clamping kit, according to DIN 42 538 standards, simply specify KBCD-400B.Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket.

Page 25: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

24

01/2

011

Up to 36 kV - 1250 A

400AR-4INTERFACE C

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

Specifications and standardsThe bolted type equipment bushings 400AR-4 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137.

Ordering instructionsTo order the equipment bushing, specify the type.The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering.E.g. M400AR-4/GS.

In mm.

40

10

138

329

Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm

36

139

Dia. 150Dia. 100Dia. 70

M16

Dia. 32

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

400AR-4K400AR-4M400AR-4

122436

125012501250

Page 26: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

25

FIXINGS FOR EQUIPMENT BUSHINGS

400AR-4/GS Bushing

Bushing clamping kitTo order the bushing clamping kit, according to NFC 52-053standards, simply specify KBCNF-400.Contents: - 4 x claw clamp NF - 1 x sealing gasket.

In mm.

Fixing dimensions standards NF C 52-053French standards.

400AR-4/J Bushing

NF C 52-053claw clamp

earth plate

bushing interface

fixing studs

equipment

equipmentconnection

sealing gasket

earth jumper

F DIN 42 538stud clamp

fixing flange

Bushing clamping kitTo order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400.Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN 42 538 - 1 x sealing gasket.

Fixing dimensions

Dia. 105Dia. 171

6030

6 fixingstuds

M10M10 or

M12

Dia. 105Dia. 171

50 to70 25

4 fixingstuds

Page 27: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

26

01/2

011

Up to 36 kV - 1250 A

400AR-5INTERFACE C

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

Ordering instructionsTo order the equipment bushing, specify the type.The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering.E.g. M400AR-5/GS.

In mm.

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

400AR-5K400AR-5M400AR-5

122436

125012501250

32

72

245

Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm

36

139

Dia. 150Dia. 76

M16

Dia. 32

Specifications and standardsThe bolted type equipment bushings 400AR-5 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137.

Page 28: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

27

FIXINGS FOR EQUIPMENT BUSHINGS

400AR-5/GS Bushing

In mm.

NF C 52-053claw clamp

earth plate

bushing interface

fixing studs

equipment

equipmentconnection

sealing gasket

earth jumper

F DIN 42 538stud clamp

fixing flange

Bushing clamping kitTo order the bushing clamping kit, according to NFC 52-053standards, simply specify KBCNF-400.Contents: - 4 x claw clamp NF - 1 x sealing gasket.

Fixing dimensions standards NF C 52-053French standards.

Bushing clamping kitTo order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400.Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN 42 538 - 1 x sealing gasket.

Fixing dimensions

Dia. 105Dia. 171

6030

6 fixingstuds

M10M10 or

M12

Dia. 105Dia. 171

50 to70 25

4 fixingstuds

400AR-5/J Bushing

Page 29: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

28

01/2

011

Up to 36 kV - 630 A

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

400AR-6

K400AR-6

M400AR-6

12

24

36

630

630

630

400AR-6INTERFACE C

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

Ordering instructionsTo order the equipment bushing, specify the type.The bushings can be supplied with an earth jumper (/J). This earth connection must be specified when ordering.E.g. M400AR-6/J.

In mm.

Specifications and standardsThe bolted type equipment bushings 400AR-6 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137.

40

Dia. 128Dia. 74Dia. 70

10

213

398

Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm

30

133

Dia.25

M16

Page 30: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

29

FIXINGS FOR EQUIPMENT BUSHINGS

400AR-6/J Bushing Bushing clamping kitTo order the bushing clamp-ing kit, according to DIN 42 538 standards, simply specify KBCD-400B.Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket.

In mm.

Fixing dimensions standards DIN 42 538German standards.

equipmentconnection

fixing studs

bushing interface

equipment

sealing gasket

fixing flangeB DIN 42 538

E DIN 42 538stud clamp

earth jumper

M10

55

Dia. 140Dia. 80

25

6 fixingstuds

Page 31: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

30

01/2

011

Up to 36 kV630 A & 1250 A

400SFR-BINTERFACE C

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with SF6 gas.

DesignThe equipment bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The 400SFR-B bushing has a shank outside this standard, adapted to use in SF6 gas.

Technical characteristics Each bushing is tested forAC withstand and partialdischarge prior to leaving thefactory.

Ordering instructionsTo order the equipment bushing, simply specify the type.

Specifications and standardsThe bolted type equipment bushing 400SFR-B meets the requirements of CENELEC EN 50180 and IEC 60137.

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

Dia. D(mm)

400SFR-B

K400SFR-B

M400SFR-B

400SFR-B 1250 A

K400SFR-B 1250 A

M400SFR-B 1250 A

12

24

36

12

24

36

630

630

630

1250

1250

1250

25

25

25

32

32

32

Dia. 70

95

33

219.5

Dia. 70

Dia. 109

Dia. D

M12

In mm.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Page 32: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

31

FIXINGS FOR EQUIPMENT BUSHINGS

400SFR-B Bushing for gas insulated switchgear

In mm.

MOUNTED

equipment

sealingO-ringgasket

equipmentconnection

bushinginterface 6 fixing

screwsM6

60°

60°60°

UNMOUNTED

Dia. 91.5Dia. 103.1

83

earthconnection

M4

M6

M4

Page 33: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

32

01/2

011

400A-24BINTERFACE C

IN-AIR BUSHING

Up to 24 kV - 630 A

Ordering instructionsTo order the equipment bushing, specify the type.The bushings are supplied with an earth jumper.To include the ring clamp, add:������������������������� �� �����������������!������� �� ����"���������"��������� �� �#E.g. 400A-24B/D.For use in potentially explosive atmospheres (for 12 kV max), order: -/ATEX.

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

Creepage distanceA-B

(mm)

400A-24B

400A-24B

12

24

630

630

520

520

In mm.Dia. 80

30

20

Dia. 80

Dia. 110

40

250

434

M16 B

A

Dia.25

ApplicationFor use in equipment insulated with air, typically for dry type transformers, motors, switchgear, capacitors...

Specifications and standardsThe bolted type equipment bushings 400A-24B are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180, IEC 60071 and IEC 60137.

Page 34: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

33

400A-24B In-air bushing

In mm

FIXINGS FOR EQUIPMENT BUSHINGS

10

Dia.12

Type BCA-B : BS 2562 British standardsType BCA-D : DIN 42 538 German standards

4Dia. 94.5

Dia. 111

BS 2562 stand.: 120DIN 42 538 stand.: 123

Dia. 150

F

120°

120°

Type BCA-F : NFC 52-053 French standards

Dia. 150

10

Dia.124

Dia. 94.5

Dia. 111

126

fixing studs andnuts M10

bushing interface

earth jumper

equipment

gasket

equipmentconnection

fixing flangeBCA-B orBCA-D

fixing flangeBCA-F

Fixing dimensions standards NF C 52-053French standards.

Fixing dimensions standards DIN 42 538German standards.

M10

Dia. 123Dia. 82

5520

4 fixingstuds

3 fixingstuds

Dia. 82

5220

M10

Dia. 126

Page 35: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

34

01/2

011

ApplicationSurge arrester designed to protect 12, 24 and 36 kV class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching.It has been designed to be used with the 430TB or 434TB separable tee connector.

Up to 36 kV

300SASURGE ARRESTER

FOR 430TB AND 434TB CONNECTOR

Technical characteristics ����������$����������������!�����

oxide varistor surge arrester in an elbow configuration.

����������������������� ������%�withstand, partial discharge and critical voltage prior to leaving the factory.

Surgearrester

type

Nominal discharge

currentIn (kA)

Rated voltageUr (kV)

Max. continuousoperatingvoltageUc (kV)

Dimensions(mm)

L1 L2

300SA-10-15N300SA-10-18N300SA-10-22N300SA-10-24N300SA-10-30N300SA-10-36N300SA-10-45N

10101010101010

15182224303645

12.014.417.619.224.028.836.0

230230230320320320430

270270270360360360470

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Dia.65 mm

170 mm

105 mm

Dia.75 mm

L2

L1

5

2

1

3

4

6

7

8

9

DesignSurge arrester comprising:1. Interface designed to fit the 430TB/G or 434TB/G tee connector. 2. Conductive EPDM insert.3. Conductive EPDM jacket.4. Insulating EPDM layer moulded between the insert and the jacket.5. Receptacle for contact rod.6. Metal oxide valve elements.7. Steel cap.8. Earth connection.9. Earth lead.

Specifications and standardsThe 300SA surge arresters meet the test requirements of IEC 60099-4.

Page 36: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

35

Typical application anddimensions

Ordering instructionsTo order the surge arrester, specify the surge arrester type, as described on previous page.

Example:For a maximum continuous operating voltage (r.m.s.) of 24 kV and a nominal discharge current of 10 kA.Order a 300SA-10-30N surge arrester.

Technical data

Surgearrester

type

Steep currentresidual

voltage @ 10 kA[1/20 μs] (kV)

Lightning currentresidual voltage[8/20 μs] (kV)

Switching impulseresidual voltage[36/90 μs] (kV)

High currentimpulse

withstand(kA)@ 5 kA @ 10 kA @ 20 kA @ 125 A @ 500 A

300SA-10-15N300SA-10-18N300SA-10-22N300SA-10-24N300SA-10-30N300SA-10-36N300SA-10-45N

48.158.170.177.097.0

115.9144.1

39.748.057.963.680.195.7

119.0

43.252.263.069.287.2

104.2129.5

48.458.570.677.697.7

116.8145.1

30.536.844.448.861.573.591.3

32.539.247.352.065.578.397.3

100100100100100100100

290 mm

180 mm 107 mm

Type430TB or

434TBtee connector

Type 300SAsurge arrester

Page 37: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

36

01/2

011

ApplicationSurge arrester designed to protect medium voltage components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching.

Up to 36 kV

400PB-XSAINTERFACE C

SURGE ARRESTER

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Surgearrester

type

Nominal discharge

currentIn (kA)

Rated voltageUr (kV)

Max. continuousoperatingvoltageUc (kV)

Dimensions(mm)

L1 L2

400PB-5SA-15L400PB-5SA-18L400PB-5SA-22L400PB-5SA-24L400PB-5SA-30L

400PB-10SA-15N400PB-10SA-18N400PB-10SA-22N400PB-10SA-24N400PB-10SA-30N400PB-10SA-36N400PB-10SA-45N

55555

10101010101010

151822243015182224303645

12.014.417.619.224.012.014.017.619.224.028.836.0

250250350350350250250350350350350450

290290390390390290290390390390390490

Technical characteristics ����������$����������������!�����

oxide varistor surge arrester in an elbow configuration.

����������������������� ������%�withstand, partial discharge and critical voltage prior to leaving the factory.

4

1

2

3

8

7

6

5

9

252 mm

150 mm

Dia.80 mm

L2L1

Dia.70 mm

DesignSurge arrester comprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer moulded between the insert and the jacket.4. Contact rod.5. Earthing lead.6. Earth connection.7. Steel cap.8. Metal oxide valve elements.9. Type C - 630 A interface as described by CENELEC EN 50180 and 50181.

Specifications and standardsThe 400PB-XSA surge arresters meet the test requirements of IEC 60099-4.

Page 38: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

37

Typical applications anddimensions

Ordering instructionsTo order the surge arrester, specify the surge arrester type, as described on previous page.

Example:For a maximum continuous operating voltage (r.m.s.) of 24 kV and a nominal discharge current of 10 kA.Order a 400PB-10SA-30N surge arrester.

Technical data

Surgearrester

type

Steep currentresidual

voltage @ 10 kA[1/20 μs] (kV)

Lightning currentresidual voltage[8/20 μs] (kV)

Switching impulseresidual voltage[36/90 μs] (kV)

High currentimpulse

withstand(kA)@ 5 kA @ 10 kA @ 20 kA @ 125 A @ 500 A

400PB-5SA-15L400PB-5SA-18L400PB-5SA-22L400PB-5SA-24L400PB-5SA-30L

400PB-10SA-15N400PB-10SA-18N400PB-10SA-22N400PB-10SA-24N400PB-10SA-30N400PB-10SA-36N400PB-10SA-45N

47.156.569.275.294.048.158.170.177.097.0

115.9144.1

38.946.757.162.177.639.748.057.963.680.195.7

119.0

42.350.862.267.684.543.252.263.069.287.2

104.2129.5

47.456.969.775.894.748.458.570.677.697.7

116.8145.1

29.835.843.847.759.630.536.844.448.861.573.591.3

31.838.246.750.863.532.539.247.352.065.578.397.3

6565656565100100100100100100100

185 mm

410 mm

220 mm

Type400TB

or 440TBtee connector

Type 400PB-5SAor 400PB-10SAsurge arrester

Page 39: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

38

01/2

011

400TR and 400TR-LBINTERFACE C

TEST RODS

Application������������� ���������� ����* - cable fault location - cable testing - phasing checks, etc.��%����������!�;����!� ��

with a cable lug, a 4 mm plug or spring clips.

InstallationThe test rod is mounted onto the clamping screw in the type C interface tee and coupling connectors. The test cable is connected to the threaded stem and the insulating shroud moved to its final position over the end of the test rod.

Design1. Insulating shroud.2. Threaded rod for test connection.3. Two nuts M12.4. Insulation.5. Copper test rod stem.6. Wing nut.

An insulating shroud isprovided to allow theapplication of test voltageswhen bushings are closelyspaced.

Test rod type

Maximum A.C.test voltage

(50 Hz - 1 min)

Maximum D.C.test voltage

(8 x U0 - 30 min)

Impulse voltage (1.2 x 50 μs)

min

400TR

400TR-LB

36 kV

36 kV

96 kV

96 kV

95 kV

95 kV

Technical characteristics ������<==�>�������� ����

be used with 400TE, 430TB, 400TB and 440TB connectors.

������<==�>?@�������������Q����the 400LB connector.

In mm.

400TR 400TR-LB

Ordering instructionsSimply specify:400TR or 400TR-LB test rod.

465

310

M10

Dia.25

60

1

2

6

4

5

1

2

4 288

480

403

5

M12

Page 40: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

39

01/2

011

400TK & 400SWINSTALLATION TOOL

Application��������Y����������� ���Y�

spanner key are designed to facilitate assembly of 400TE, 400TB and 440TB connectors.

������<==�Z���Y������������used to install the 400TEF clamping pin contact or 400TCS clamping screw.

Ordering instructionsSimply specify:- 400TK box spanner- 400SW box spanner key

������<==[\���Y���������key fits on the hex nut of the 400BIPA basic insulating plug.

400TK

400SW

Page 41: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

40

01/2

011

ACCESSORIESINTERFACE C

Up to 36 kVApplicationFor use with connectors and bushings with an interface C as described by CENELEC EN 50180 and 50181.

Technical characteristics All these products, except theearthing plugs, are tested forAC withstand and partial discharge prior to leavingthe factory.

400SOP-BStand-off plugIs designed to support and 'dead-end' connectors with a type C interface when removed from equipment.

Ordering instructionsOrder 400SOP-B for 12 kV,K400SOP-B for 24 kV,M400SOP-B for 36 kV orP400SOP-B for 41.5 kVapplications.

400GP-BEarthing plugIs designed to support and earth connectors with a type C interface when removed from equipment.

Ordering instructionsOrder 400GP-B for 12, 24, 36 or41.5 kV applications.

300GP-BEarthing plugIs designed to earth the 430TB and 434TB connectors when it is fixed-mounted to the equipment (maintenance earthing).

Ordering instructionsOrder 300GP-B for 12, 24, 36 or41.5 kV applications.

400DR-BDead-end receptacleFits over a bushing with a type C interface to provide 'dead-end' facility.

Ordering instructionsOrder 400DR-B for 12 kV,K400DR-B for 24 kV orM400DR-B for 36 kVapplications.The dead-end receptacle canbe supplied with an earth lead.Order with suffix -/G.E.g. K400DR-B/G.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Page 42: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

41

Kit MTEarthing kit for copper tape screened cablesContains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and some water sealing mastic.

Ordering instructionsOrder Kit MT for 12 kV, 24 kV 36 kV or 41.5 kV applications.

400RTPAReducing tap plugProvides a type A interface to connectors with a type C interface.A 'C' spanner, 600SW, is used to tighten the reducing tap plug on to its mating part.

Ordering instructionsOrder 400RTPA for 12 kV or K400RTPA for 24 kVapplications.

Order 600SW for the 'C'spanner.

400CP-SCConnecting plugFor connecting two or more connectors with a type C interface together, thus creating a separable cable joint or a multiple cable connection to equipment.

Ordering instructionsOrder 400CP-SC for 12 kV, K400CP-SC for 24 kV orM400CP-SC for 36 kVapplications.

400BIPABasic insulating plugActs as a tightening nut for the 400TB and 440TB tee connector kits.The plug contains a voltage detection point.The conductive rubber protection cap is included.

Ordering instructionsOrder 400BIPA for 12 kV, K400BIPA for 24 kV M400BIPA for 36 kV orP400BIPA for 41.5 kVapplications.

440CPConnecting plugFor connecting two or more 440TB connectors, thus creating a separable cable joint or a multiple cable connection to equipment.For use up to 1250 A.Only for use with 440TB.

Ordering instructionsOrder 440CP for 12 kV, K440CP for 24 kV orM440CP for 36 kVapplications.

Order (K)(M)440CP + 676SA for connection to an already installed 440TB connector.

430CPConnecting plugFor connecting two or more 430TB connectors, thus creating a separable cable joint or a multiple cable connection to equipment.

Ordering instructionsOrder 430CP for 12 kV orK430CP for 24 kV applications.

Page 43: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

42

01/2

011

POSSIBLE ARRANGEMENTSINTERFACE C

430TBSingle cable arrangement.Order 430TB for 12 kV,K430TB for 24 kV or M430TB for 36 kV applications.

430TBM-P2Dual cable arrangement.Order 430TBM-P2 for 12 kV,K430TBM-P2 for 24 kV or M430TBM-P2 for 36 kV applications.

In mm.

430TBM-P3Triple cable arrangement.Order 430TBM-P3 for 12 kV,K430TBM-P3 for 24 kV or M430TBM-P3 for 36 kV applications.

430TBM-L33-way connection.Order 430TBM-L3 for 12 kV,K430TBM-L3 for 24 kV or M430TBM-L3 for 36 kV applications.

185

300BIPAbasicinsulatingplug

430TB teeconnector

425

300PBMcouplingconnectors

430TB tee connector

400BIPA basic

insulating plug

300BIPAbasicinsulatingplug

110 105

430TB teeconnector

300PBMcouplingconnector

290

300BIPAbasicinsulatingplug

300BIPAbasicinsulatingplug

300PBMcouplingconnectors

430TB teeconnector

Page 44: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

43

434TBSingle cable arrangement.Order 434TB for 12 kV,K434TB for 24 kV or M434TB for 36 kV applications.

110 155

440PBcouplingconnector

434TBteeconnector

300BIPAbasicinsulatingplug

345

434TBM-P2Dual cable arrangement.Order 434TBM-P2 for 12 kV,K434TBM-P2 for 24 kV or M434TBM-P2 for 36 kV applications.

434TBM-P2 + 300SADual cable arrangement with surge arrester.Order 434TBM-P2+300SA for 12 kV, K434TBM-P2+300SA for 24 kV or M434TBM-P2+300SA for 36 kV applications.

440TB + 400PB-XSACable arrangement with surge arrester.Order 440TB+400PB-XSA for 12 kV, K440TB+400PB-XSA for 24 kV or M440TB+400PB-XSA for 36 kV applications.

110

185

300BIPAbasicinsulatingplug

434TB teeconnector

110

400BIPA basicinsulatingplug

400PB-XSAsurge arrester

440TBtee connector

410

110 155

450

300BIPA basicinsulatingplug

440PBcouplingconnector

300SAsurge arrester

434TBtee connector

Page 45: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

44

In mm.

400TB/GSingle cable arrangement.Order 400TB/G for 12 kV, K400TB/G for 24 kV,M400TB/G for 36 kV or P400TB/G for 41.5 kV applications.

400TB/G-P2Dual cable arrangement.Order 400TB/G-P2 for 12 kV, K400TB/G-P2 for 24 kV or M400TB/G-P2 for 36 kV applications.

400TB/G-L22-way connection.Order 400TB/G-L2 for 12 kV, K400TB/G-L2 for 24 kV or M400TB/G-L2 for 36 kV applications.

250

teeconnector

basicinsulatingplug

110

400TB/G-L33-way connection.Order 400TB/G-L3 for 12 kV, K400TB/G-L3 for 24 kV or M400TB/G-L3 for 36 kV applications.

500

110 245

basicinsulating

plug

connectingplug

Page 46: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

45

Connector on stand-off plugOrder 400SOP-B for 12 kV, K400SOP-B for 24 kV or M400SOP-B for 36 kV applications.

In mm.

400TB/G-L4Disconnectable tap-off.Order 400TB/G-L4 for 12 kV, K400TB/G-L4 for 24 kV or M400TB/G-L4 for 36 kV applications.

400TB/G-L52-way connection with tap-off.Order 400TB/G-L5 for 12 kV or K400TB/G-L5 for 24 kV applications.

505

400TB/G teeconnectorstand-off

plug

400BIPAbasicinsulatingplug

430TB teeconnector

stand-offplug

300BIPAbasicinsulatingplug

Page 47: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

46

Earthing plug on connectorOrder 300GP-B for 12 kV, 24 kV and 36 kV applications.

In mm.

Cable and equipment testing

Connector on earthing plugOrder 400GP-B for 12 kV, 24 kV and 36 kV applications.

Page 48: a Nexans company - Nexans Power Accessories Germany · PDF file1 01/2011 While every care is taken to ensure that the information contained in this publication is correct, no legal

Additional catalogue information on power cable accessoriesis available by contacting us at the address below: