+ All Categories
Home > Documents > Access & Power Integration Trove2HW2 THW2

Access & Power Integration Trove2HW2 THW2

Date post: 22-Feb-2022
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
12
Rev. THW2103017 Trove2HW2 - Trove2 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW2) THW2 - Altronix/Honeywell ProWatch/WinPak backplane only Trove3HW3 - Trove3 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW3) THW3 - Altronix/Honeywell ProWatch/WinPak backplane only Installation Guide All registered trademarks are property of their respective owners. More than just power.™ Installing Company: _____________________ Service Rep. Name: __________________________________________ Address: ________________________________________________________ Phone #: _________________________ Access & Power Integration
Transcript
Page 1: Access & Power Integration Trove2HW2 THW2

Rev. THW2103017

Trove2HW2 - Trove2 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW2)

THW2 - Altronix/Honeywell ProWatch/WinPak backplane only

Trove3HW3 - Trove3 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW3)

THW3 - Altronix/Honeywell ProWatch/WinPak backplane only

Installation Guide

All registered trademarks are property of their respective owners. More than just power.™

Installing Company: _____________________ Service Rep. Name: __________________________________________

Address: ________________________________________________________ Phone #: _________________________

Access & Power Integration

Page 2: Access & Power Integration Trove2HW2 THW2

- 2 - TroveHW

Overview:Trove2HW2 and Trove3HW3 accommodate various combinations of Honeywell ProWatch/WinPak boards with or without Altronix power supplies and accessories for access systems.

Specifications:

Installation Instructions:Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware.2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.3. Mount included UL Listed tamper switch(es) (Honeywell Model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.4. Mount Altronix/Honeywell boards to backplane, refer to pages 3-6.

Fig. 1

Trove2HW2- Trove2 enclosure with THW2 Altronix/Honeywell backplane.• Includes: tamper switch, cam lock, mounting hardware.• 16 Gauge grey enclosure with ample knockouts for convenient access. Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm). Accommodates up to four (4) 12VDC/7AH batteries.

THW2- THW2 Altronix/Honeywell backplane.• 16 Gauge backplane.• Includes mounting hardware. Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.6mm x 492.1mm x 7.9mm).

THW2 accommodates a combination of the following:Altronix:• Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.• Up to four (4) ACM8(CB) or ACM8S(CB).• Up to three (2) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), or VR6.Honeywell:• Up to six (6) PRO32IC, PRO32R2, PRO32IN, PRO32OUT, PW51KEN, PW6K1IC, PW6K1IN, PW6K1OUT, PW6K1R2 modules.• One (1) PRO32E1PS or PW6K2E2PS power supply.• Up to two (2) PW6K1ICE or PW6K1R1E modules.

Trove3HW3- Trove3 enclosure with THW3 Altronix/Honeywell backplane.• Includes: two (2) tamper switches, cam lock, mounting hardware.• 16 Gauge grey enclosure with ample knockouts for convenient access. Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm). Accommodates up to four (4) 12VDC/12AH batteries.

THW3- THW3 Altronix/Honeywell backplane.• 16 Gauge backplane.• Includes mounting hardware. Dimensions (H x W x D): 34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm).

THW3 accommodates a combination of the following:Altronix:• Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.• Up to four (4) ACM8(CB) or ACM8S(CB).• Up to six (6) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), or VR6.Honeywell:• Up to nine (9) PRO32IC, PRO32R2, PRO32IN, PRO32OUT, PW51KEN, PW6K1IC, PW6K1IN, PW6K1OUT, PW6K1R2 modules.• Up to two (2) PRO32E1PS or PW6K2E2PS power supplies.• Up to two (2) PRO22MX8 modules.

Edge of Enclosure

to Access Control Panel or U.L. Listed

Reporting Device

Enclosure

Honeywellmodel # 112

Tamper Switchor equivalent(provided)

Page 3: Access & Power Integration Trove2HW2 THW2

TroveHW - 3 -

Installation Instructions for Altronix Power Supplies and Sub-Assemblies to THW2:1. Fasten standoffs (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 2).2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2a, pg. 2).3. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models:Altronix Board Pem Mounting

Altronix Power Supply/Charger or Sub-Assembly

A

Altronix Sub-Assembly B

Pem

Standoff

AltronixPower Supply or Sub-Assembly

BackplanePan HeadScrew

Metal Standoff Placement

Metal Standoff Placement

Metal Standoff Placement

Metal Standoff Placement

A

AB

AB

AB

Fig. 2a

Fig. 2

Page 4: Access & Power Integration Trove2HW2 THW2

- 4 - TroveHW

Installation Instructions for Honeywell PRO32E1PS or PW6K2E2PS to THW2:1. Install four (4) mounting screws approximately halfway into mounting holes in the power supply’s frame.2. Position the power supply over four (4) keyholes (B) on THW2 so the AC Input terminal marked [CN1] (smaller opening in the frame) is positioned to the left.3. Slide the power supply to the left until secure. Tighten the mounting screws.

Installation Instructions for Honeywell Access Controllers to THW2:1. Fasten standoffs (provided) into pem configuration (A) or (C) of backplane (Fig. 3, pg. 4).2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 3a, pg. 4).3. Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Power Supply or Access Controller Position Chart for the Following Models:Honeywell Board Pem Mounting

3200 Series or WIN-PAK Series A

PRO32E1PS or PW6K2E2PS B

PW6K1ICE or PW6K1R1E C

Pem

Standoff

HoneywellAccess Controller

BackplanePan HeadScrew

Fig. 3a

AB

A

A

C

A

A

A

C

Fig. 3

Page 5: Access & Power Integration Trove2HW2 THW2

TroveHW - 5 -

Installation Instructions for Altronix Power Supplies and Sub-Assemblies to THW3:1. Fasten standoffs (provided) into pem configuration (A) or (B) of backplane (Fig. 4, pg. 5).2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 4a, pg. 5).3. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models:Altronix Board Pem Mounting

Altronix Power Supply/Charger or Sub-Assembly

A

Altronix Sub-Assembly B

Pem

Standoff

AltronixPower Supply or Sub-Assembly

BackplanePan HeadScrew

Metal Standoff Placement

A

Metal Standoff Placement

A

Metal Standoff Placement

AB

Metal Standoff Placement

AB

B B

B B

Fig. 4a

Fig. 4

Page 6: Access & Power Integration Trove2HW2 THW2

- 6 - TroveHW

Installation Instructions for Honeywell PRO32E1PS or PW6K2E2PS to THW3:1. Install four (4) mounting screws approximately halfway into mounting holes in the power supply’s frame.2. Position the power supply over four (4) keyholes (B) on THW3 so the AC Input terminal marked [CN1] (smaller opening in the frame) is positioned to the bottom.3. Slide the power supply to the left until secure. Tighten the mounting screws.

Installation Instructions for Honeywell Access Controllers to THW3:1. Fasten standoffs (provided) into pem configuration (A) or (C) of backplane (Fig. 5, pg. 6).2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 5a, pg. 6).3. Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Power Supply or Access Controller Position Chart for the Following Models:Honeywell Board Pem Mounting

3200 Series or WIN-PAK Series A

PRO32E1PS or PW6K2E2PS B

PRO22MX8 C

Pem

Standoff

HoneywellAccess Controller

BackplanePan HeadScrew

Fig. 5a

AA

A

A

A

A

A

A

A

B

B

C C

Fig. 5

Page 7: Access & Power Integration Trove2HW2 THW2

TroveHW - 7 -

eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network...

LINQ2 Mounts Inside any Trove Enclosure

LINQ2 - Network Communication ModuleLINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini-mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).

LINQ2

Features:- UL Listed in the U.S. and Canada.- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.- Access control and user managment: Restrict read/write, Restrict users to specific resources- Two (2) integral network controlled Form “C” Relays.- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.- Email and Windows Dashboard notifications- Event log tracks history.- Secure Socket Layer (SSL).- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Altronix eFlowPower Supply

Network Connection:Installation, Programmingand Monitoring

Page 8: Access & Power Integration Trove2HW2 THW2

- 8 - TroveHW

Notes:

Page 9: Access & Power Integration Trove2HW2 THW2

TroveHW - 9 -

2.2”(55.9mm)

2.2”(55.9mm)

7.5”(190.5mm)

25.375”(644.6mm)

19.375”(492.1mm)

12.625”(320.7mm)

0.45”(11.4mm)

1.0” (25.4mm)

1.0” (25.4mm)

9.2”(233.7mm)

8.5”(215.9mm)

16.25”(412.8mm)

0.156”( 3.96mm)

9.2”(233.7mm)

7.5”(190.5mm)

0.45”(11.4mm)

THW2 Dimensions (H x W x D):25.375” x 19.375” x 0.3125” (644.6mm x 492.1mm x 7.9mm)

Page 10: Access & Power Integration Trove2HW2 THW2

- 10 - TroveHW

Trove2 Enclosure Dimensions (H x W x D approximate):27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)

G

1.25”(31.75mm)

1.25”(31.75mm)

6.25”(158.75mm)

6.25”(158.75mm)

6.75”(171.45mm)

8.25”(209.54mm)

8.00”(203.2mm)

1.5”(38.1mm)

1.25”(31.75mm)

0.85”(21.59mm)

0.85”(21.59mm)

1.00”(25.4mm)

2.00”(50.8mm)

1.25”(31.75mm)

2.00”(50.8mm)

2.00”(50.8mm)

5.25”(133.35mm)

5.25”(133.35mm)

7.00”(177.79mm)

2.00”(50.8mm)

2.00”(50.8mm)

27.00”(685.8mm)

3.50”(88.9mm)

0.5625”(14.29mm)

2.415”(61.34mm)

0.685”(17.399mm)

1.77”(44.96mm)

3.50”(88.9mm)

21.50”(546.1mm)

19.80”(502.92mm)

5.25”(133.35mm)

5.25”(133.35mm)

0.885” (22.479mm)1.125” (28.32mm)Knockouts

Page 11: Access & Power Integration Trove2HW2 THW2

TroveHW - 11 -

0.45”(11.4mm) 2.5”

(63.5mm)

2”(50.8mm)

13.5”(342.9mm)

13.5”(342.9mm)

13.5”(342.9mm)

25”(635mm)

0.156”( 3.96mm)

1.0” (25.4mm)

1.0” (25.4mm)

34”(863.6mm)

28”(711.2mm)

THW3 Dimensions (H x W x D):34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm)

Page 12: Access & Power Integration Trove2HW2 THW2

- 12 - TroveHW

Altronix is not responsible for any typographical errors.

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056web site: www.altronix.com | e-mail: [email protected] | Made in U.S.A.IITroveHW I10R MEMBER

Trove3 Enclosure Dimensions (H x W x D approximate):36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)

G

G

2.00”(50.8mm)

8.75”(222.3mm)

8.75”(222.3mm)

8.62”(219mm)

7.06”(179.3mm)

1.25”(31.8mm)

1.25”(31.8mm)

2.00”(50.8mm)

7.12”(222.25mm)

9.5”(241.3mm)

30.12”(768.1mm)

14.01”(355.9mm)

14.01”(355.9mm)

9.5”(241.3mm)

1.25”(31.75mm)

1.55”(39.37mm)

1.78”(45.21mm)

1.25”(31.8mm)

1.07”(27.2mm)

1.10”(27.9mm)

2.00”(50.8mm)

10.75”(273.1mm)

10.75”(273.1mm)

10.62”(269.8mm)

2.00”(50.8mm)

10.75”(273.1mm)

10.75”(273.1mm)

10.62”(269.8mm)

36.12”(917.5mm)

33.63”(854.20mm)


Recommended