ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE · combustibles. It is also recommended that the...

Date post: 24-Aug-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
4
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com 1 0.750 17 5 8 " 12 15 16 " 1 4 " MAX ADJUSTMENT ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE W415-1870 / A / 02.04.19 Specifications Front Options Framing Dimensions Model BTU Width Height Depth Viewing Area Actual Framing Actual Framing Actual Framing L50N 30,000 65 5/16 65 13/16 41 3/16 73 17 11/16 17 15/16 52 3/4 X 18 5/8 L50N2 30,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8 single-sided Ref L50 E 17 15/16” (45.6cm) F 65 13/16” (167.2cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E J F minimum framing L note: The L series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Before framing the appliance, ensure to install the firestop first. see-thru Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after framing. * Minimum enclosure height maybe higher depending on vent- ing configuration (see minimum distance to combustibles). Ref L50 E 16 3/16” (41.1cm) F 65 13/16” (167.2cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E F J minimum framing L note: The L series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information. SSB50SS SLF50K / SS 1 1 4 " MAX ADJUSTMENT MIN. PROJECTION FROM FINISHING MATERIAL 3 8 " 53 7 16 " 47 3 8 " 19 3 4 " 12 15 16 " 51 7/8” 47 3/16”
Transcript
Page 1: ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE · combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Before

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

A

1

0.750

17 58 "

12 1516 "

35 316

"

14"

MAX ADJUSTMENT

ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE

W415-1870 / A / 02.04.19

Specifi cations

Front Options

Framing Dimensions

Model BTUWidth Height Depth

Viewing AreaActual Framing Actual Framing Actual Framing

L50N 30,000 65 5/16 65 13/16 41 3/16 73 17 11/16 17 15/16 52 3/4 X 18 5/8

L50N2 30,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8

single-sided

Ref L50

E 17 15/16” (45.6cm)

F 65 13/16” (167.2cm)

J Optional - Appliance does not need to be elevated above fl oor

*L 73” (185.4cm)

EJ

F

minimum framing

L

note:The L series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air.

note:Before framing the appliance, ensure to install the fi restop fi rst.

see-thru

Before framing the appliance, ensure to install the fi restop fi rst as it will not fi t between the studs if installed after framing.

* Minimum enclosure height maybe higher depending on vent-ing confi guration (see minimum distance to combustibles).

Ref L50

E 16 3/16” (41.1cm)

F 65 13/16” (167.2cm)

J Optional - Appliance does not need to be elevated above fl oor

*L 73” (185.4cm)

E F

Jminimum framing

L

note:The L series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air.

note:

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

SSB50SS SLF50K / SS

1 14"

MAX ADJUSTMENT

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"19 34

"12 15

16"

51 7/8”

47 3/16”

Page 2: ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE · combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Before

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

Dimensions

Wall Penetration

Appliance LocationCombustible Mantel Clearances

L50

A(Finishing Flange)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

17 11/16"

1/2"[12.7mm]

449mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

SAFETY BARRIER

*

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

Base of air collar

single-sided

L50

A(Finishing Flange)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

(

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

SAFETY BARRIER

**

Base of air collarsee-thru

single-sided

The L series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air.

note:

Shaded components (fi nish framing) must be non-combustible materials.

note:

3” [76mm] top (outside of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible fi nishing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to bottom of the appliance

0” to side standoffs

1/2” fi nishing fl ange

When passing through a ceiling, use fi restop spacer W500-0028 (not supplied)

When passing through a wall, use fi restop spacer W615-0162 (supplied with W010-4178 fi restop spacer assembly)

1” [25mm] minimum all sides for sections of vertical venting.

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all verti-cal runs to combustibles is required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

3” [76mm] top (outside of enclosure)

73”minimum

2” [51mm] sides / bottom (outside of enclosure)

see-thru

73”minimum

The L series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the appliance. For temperature requirements, this area must be left unobstruct-ed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. It is also recom-mended that the enclosure be ventilated at the top and bottom to circulate the hot air.

note:

Shaded components (fi nish framing) must be non-combustible materials.

note:

SAFETY BARRIER

1/2” fi nishing fl ange (4 sides)

3” [76mm] top (out-side of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible fi nish-ing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to side standoffs

0” to base of the appliance

When passing through a ceiling, use fi restop spacer W500-0028 (not supplied)

When passing through a wall, use fi restop spacer W615-0162 (sup-plied with W010-4178 fi restop spacer assembly)

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] top (outside of enclosure)

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

14”(35.6cm)

min.

2” [51mm] sides / bottom (outside of enclosure)

0

MANTEL DEPTH

1 2 3 4 5 6 7 8 9 10112468

1012141618202224

A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of fi nishing fl ange

Optional hearth extension (no

depth restriction)

MANTEL HEIGHT

MANTEL DEPTH

Min. height is 18” (45.7cm) for a 2” (50mm) protrusion as a starting point.

note:

Do not put objects in front of theappliance (minimum distance of 4 feet)

L50

*E 17 15/16” (45.6cm)

F 65 13/16” (167.2cm)

G 72 1/4” (183.5cm)

H 18 3/16” (46.2cm)

I 102 3/16” (259.5cm)

F

G

1” (2.54cm) min.

6” (15.2cm) min.

F

H

I

*E

minimum framing

W415-1870 / A / 02.04.19

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

Page 3: ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE · combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Before

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

A

1

0.750

17 58 "

12 1516 "

35 316

"

14"

MAX ADJUSTMENT

SÉRIE ACIESMD 50 FOYER À GAZ D’ÉVACUATION DIRECTE

W415-1870 / A / 02.04.19

Specifi cations

Façades Optionnel

Dimensions d’ossature

Modèle BTULargeur Hauteur Profondeur

Dimensions de VisioneRéel Ossature Réel Ossature Réel Ossature

L50N 30,000 65 5/16 65 13/16 41 3/16 73 17 11/16 17 15/16 52 3/4 X 18 5/8

L50N2 30,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8

Ref L50

E 17 15/16” (45.6cm)

F 65 13/16” (167.2cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

EJ

F

ossature minimum

L

note:La série L requis un minimum hauteur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains confi gurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles. Aussi, nous recom-mandons que l’enceinte soit ventiler en haut et en bas pour circuler l’air chaud.

note:Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu.

Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu premier avant qu’il ne soit pas adapté entre les goujouns après l’encadrement.

* L’hauteur mini-mum de l’enceinte peut être plus grand dépendant du confi guration d’évacuation (voir distance minimum aux matériaux combustibles).

Ref L50

E 16 3/16” (41.1cm)

F 65 13/16” (167.2cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

E F

Jossature minimum

L

note:La série L requis un minimum hauteur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains confi gurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles. Aussi, nous recom-mandons que l’enceinte soit ventiler en haut et en bas pour circuler l’air chaud.

note:

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

SSB50SS SLF50K / SS

1 14"

MAX ADJUSTMENT

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"19 34

"12 15

16"

51 7/8”

un seul côté voir à travers

47 3/16”

Page 4: ACIES™ 50 DIRECT VENT LINEAR GAS APPLIANCE · combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. note: Before

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

SÉRIE ACIESMD 50 FOYER À GAZ D’ÉVACUATION DIRECTE

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

Dimensions

Passage d’un section dans un mur

Location de l’appareilDégagements Combustible de la Tablette

L50

A(Bride de finition)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

17 11/16"

1/2"[12.7mm]

449mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

Barrière de protection

*

* La profondeur de la bride de finition (la bride de finition définit le périmètre de l’ouverture de la cheminée. Les matériaux de charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition.

Base du collet d’air

L50

A(Bride de finition)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

Barrière de protection

**

Base du collet d’air

La série L nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains confi gurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles. Nous recommandons ventiler l’enceinte en haut et en bas pour circuler l’air chaud.

note:

Les composants ombragés (encadrement de fi ni-tion) doivent être de matériaux incombustibles.

note:

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux fi nitions incom-bustibles telles que le brique et la pierre

6” [152mm] minimum(dedans l’enceinte)

0” vers le bas de l’appareil

0” aux contraintes latérales

1/2” bride de fi nition

Lorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

Sections d’évents horizontales: Un dégagement minimum aux matériaux combus-tibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégagement minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégagement minimum de 1” (25mm) autour du conduit d’évacuation.

3” [76mm] haut (hors de l’enceinte)

73”minimum

2” [51mm] côtés / bas (hors de l’enceinte)

73”minimum

La série L nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains confi gurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles. Nous recommandons ventiler l’enceinte en haut et en bas pour circuler l’air chaud.

note:

Les composants ombragés (encadrement de fi ni-tion) doivent être de matériaux incombustibles.

note:

Barrière de protection

1/2” bride de fi nition

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux fi nitions incombustibles telles que le brique et la pierre

6” [152mm] minimum(dedans l’enceinte)

0” aux contraintes latérales

0” vers le bas de l’appareil

When passing through a ceiling, use fi restop spacer W500-0028 (not supplied)

Lorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] haut (hors de l’enceinte)

Sections d’évents horizontales: Un dégage-ment minimum aux matériaux combustibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégage-ment minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégage-ment minimum de 1” (25mm) autour du conduit d’évacuation.

14”(35.6cm)

min.

2” [51mm] côtés / bas (hors de l’enceinte)

0

MANTEL DEPTH

1 2 3 4 5 6 7 8 9 10112468

1012141618202224

A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of fi nishing fl ange

Base de protec-tion optionnelle

MANTEL HEIGHT

MANTEL DEPTH

L’hauteur min. est 18” (45,7cm) pour une projection de 2” (50mm) comme point de départ.

note:

Do not put objects in front of theappliance (minimum distance of 4 feet)

L50

*E 17 15/16” (45.6cm)

F 65 13/16” (167.2cm)

G 72 1/4” (183.5cm)

H 18 3/16” (46.2cm)

I 102 3/16” (259.5cm)

F

G

1” (2.54cm) min.

6” (15.2cm) min.

F

H

I

*E

ossature minimum

W415-1870 / A / 02.04.19

un seul côté voir à travers

un seul côté voir à travers

En passant par un pla-fond, utilisez l’espaceur coupe-feu W500-0028 (non fourni)

1” [25mm] minimum tous les côtés pour les sections d’évacuation verticale.

MANTEL DEPTH

Hauteur de tablette

Profondeur de tablette

Hauteur de tablette

Profondeur de tablette

Ne placez pas d’objets devant l’appareil (distance minimale de 4 pi.)

* La profondeur de la bride de finition (la bride de finition définit le périmètre de l’ouverture de la cheminée. Les matériaux de charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition.


Recommended