+ All Categories
Home > Documents > Additional features of the LZQJ-XC: LZQJ-XC · EN EMH metering GmbH & Co. KG Neu-Galliner Weg 1...

Additional features of the LZQJ-XC: LZQJ-XC · EN EMH metering GmbH & Co. KG Neu-Galliner Weg 1...

Date post: 26-Jul-2018
Category:
Upload: vuongnguyet
View: 257 times
Download: 2 times
Share this document with a friend
2
EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-mail [email protected] Web www.emh-metering.com EN EMH metering GmbH & Co. KG • Neu-Galliner Weg 1 • 19258 Gallin • GERMANY • Tel. +49 38851 326-0 • [email protected] • www.emh-metering.com Edition: 07.05.2012 LZQJXC-DAB-E-3.10 Design acc. to VDEW-Specifications 2.1 Plugable communication module Exchangeable buffer battery Network analysis Optional with DLMS LZQJ-XC Additional features of the LZQJ-XC: Measuring of instantaneous P, Q, S (per phase and sum), U, I, power factor, line frequency, values phase failures Installation check via instantaneous values (service data) possible Optical fibre interface for connection of up to 4 optical fibre separation boxes Buffer battery exchangeable buffer battery for reading out the meter via the optical interface and reading the display without power Tamper detection opening of meter and terminal cover and magnetic fields Network analysis monitoring of U, I, THD, f, flicker, harmonics acc. to DIN EN 50160 The LZQJ-XC fulfils the following standards: DIN 43857-2 Watthour meters in moulded insulation case without instrument transformers, up to 60 A rated maximum current; principal dimensions for poly-phase meters EN 50470-1 Electricity metering equipment (a.c.) - Part 1: General requirements, ests and test conditions - Metering equipment (class indexes A, B and C) EN 50470-3 Electricity metering equipment (a.c.) - Part 3: Particular requirements - Static meters for active energy (class indexes A, B and C) IEC 61000-... Electromagnetic compatibility (EMC) IEC 60529 Degrees of protection provided by enclosures (IP code) IEC 61038 Time switches for tariff and load control IEC 62052-11 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 11: Metering equipment IEC 62053-21 Electricity metering equipment (a.c.) - Particular Requirements - Part 21: Static meters for active energy (classes 1 and 2) IEC 62053-22 Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0,2 S and 0,5 S) IEC 62053-23 Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3) IEC 62056-21 Electricity metering - Data exchange for meter reading, tariff and load control - Part 21: Direct local data exchange IEC 62056-46 Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol IEC 62056-53 Electricity metering - Data exchange for meter reading, tariff and load control - Part 53: COSEM application layer IEC 62056-61 Electricity metering - Data exchange for meter reading, tariff and load control - Part 61: Object identification system (OBIS) IEC 62056-62 Electricity metering - Data exchange for meter reading, tariff and load control - Part 62: Interface classes DIN 66348-1 Interfaces and basic data link control procedures for serial measurement data communication; start-stop-transmission, point-to-point connection ITU-T V.11 Electrical characteristics for balanced double-current interchange circuits operating at data signalling rates up to 10 Mbit/s TIA/EIA-485 Electrical characteristics of generators & receivers for use in balanced digital multipoint systems ITU-T V.24 List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE) ITU-T V.28 Electrical characteristics for unbalanced double-current interchange circuits
Transcript
Page 1: Additional features of the LZQJ-XC: LZQJ-XC · EN EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-mail info@emh-metering.com

EN

EMH meteringGmbH & Co. KG

Neu-Galliner Weg 119258 GallinGERMANYTel. +49 38851 326-0Fax +49 38851 326-1129

E-mail [email protected] www.emh-metering.com

EN

EMH metering GmbH & Co. KG • Neu-Galliner Weg 1 • 19258 Gallin • GERMANY • Tel. +49 38851 326-0 • [email protected] • www.emh-metering.com

Edition: 07.05.2012LZQJXC-DAB-E-3.10

Designacc.toVDEW-Specifications2.1

Plugablecommunicationmodule

Exchangeablebufferbattery

Networkanalysis

OptionalwithDLMS

LZQJ-XCAdditional features of the LZQJ-XC:

Measuringofinstantaneous P,Q,S(perphaseandsum),U,I,powerfactor,linefrequency, valuesphasefailuresInstallationcheck viainstantaneousvalues(servicedata)possibleOpticalfibreinterface forconnectionofupto4opticalfibreseparationboxesBufferbattery exchangeablebufferbatteryforreadingoutthemeterviatheopticalinterface andreadingthedisplaywithoutpowerTamperdetection openingofmeterandterminalcoverandmagneticfieldsNetworkanalysis monitoringofU,I,THD,f,flicker,harmonicsacc.toDINEN50160

The LZQJ-XC fulfils the following standards:

DIN43857-2 Watthourmetersinmouldedinsulationcasewithoutinstrumenttransformers, upto60Aratedmaximumcurrent;principaldimensionsforpoly-phasemetersEN50470-1 Electricitymeteringequipment(a.c.)-Part1:Generalrequirements, estsandtestconditions-Meteringequipment(classindexesA,BandC)EN50470-3 Electricitymeteringequipment(a.c.)-Part3:Particularrequirements- Staticmetersforactiveenergy(classindexesA,BandC)IEC61000-... Electromagneticcompatibility(EMC)IEC60529 Degreesofprotectionprovidedbyenclosures(IPcode)IEC61038 TimeswitchesfortariffandloadcontrolIEC62052-11 Electricitymeteringequipment(AC)-Generalrequirements, testsandtestconditions-Part11:MeteringequipmentIEC62053-21 Electricitymeteringequipment(a.c.)-ParticularRequirements -Part21:Staticmetersforactiveenergy(classes1and2)IEC62053-22 Electricitymeteringequipment(a.c.)-Particularrequirements -Part22:Staticmetersforactiveenergy(classes0,2Sand0,5S)IEC62053-23 Electricitymeteringequipment(a.c.)-Particularrequirements -Part23:Staticmetersforreactiveenergy(classes2and3)IEC62056-21 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part21:DirectlocaldataexchangeIEC62056-46 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part46:DatalinklayerusingHDLCprotocolIEC62056-53 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part53:COSEMapplicationlayerIEC62056-61 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part61:Objectidentificationsystem(OBIS)IEC62056-62 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part62:InterfaceclassesDIN66348-1 Interfacesandbasicdatalinkcontrolproceduresforserialmeasurement datacommunication;start-stop-transmission,point-to-pointconnectionITU-TV.11 Electricalcharacteristicsforbalanceddouble-currentinterchangecircuits operatingatdatasignallingratesupto10Mbit/sTIA/EIA-485 Electricalcharacteristicsofgenerators&receiversforuseinbalanceddigital multipointsystemsITU-TV.24 Listofdefinitionsforinterchangecircuitsbetweendataterminalequipment(DTE) anddatacircuit-terminatingequipment(DCE)ITU-TV.28 Electricalcharacteristicsforunbalanceddouble-currentinterchangecircuits

Page 2: Additional features of the LZQJ-XC: LZQJ-XC · EN EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-mail info@emh-metering.com

Direct connection version5(60) A, 10(60) A, 5(100) A, 10(100) A

Transformer connection versionCl. B (Cl. 1)

Precision MeterCl. C (Cl. 0,5 S)

Precision MeterCl. 0,2 S

Voltage 4-wiremeter

3-wiremeter

2-wiremeter(for16,7Hz)

3x127/220V...3x240/415V

---

---

3x58/100V...3x240/415V(optional3x57,7/100...3x277/480V)

orupto3x400/690V3x100V...3x415Vorupto3x690V100V...240V

3x58/100V...3x240/415V(optional3x57,7/100...3x277/480V)

orupto3x400/690V3x100V...3x415Vorupto3x690V100V...240V

Current 5(60)A,10(60)A,5(100)A,10(100)A 5||1A,1(6)A,1(10)A,5A,1A,5(20)A 5||1A,1(6)A,1(10)A,5A,1A,5(20)AFrequency 50Hz,60Hz 50Hz,60Hz,16,7Hz 50Hz,60Hz,16,7HzAccuracy activeenergy

reactiveenergyCl.A(Cl.2),optionalCl.B(Cl.1)

Cl.3,optionalCl.2Cl.B(Cl.1)

Cl.2Cl.C(Cl.0,5S)1%(Cl.2)

Cl.0,2S0,5%(Cl.2)

Measuring system designation compensatedcurrenttransformer compensatedcurrenttransformerMeasuring types activeenergy

reactiveenergyothers

+A,-A+R,-R,R1,R2,R3,R4

S,Ah,U2h,I2h

+A,-A+R,-R,R1,R2,R3,R4

S,Ah,U2h,I2hMeter constants LED(Imp./kWh[kvarh])

output(Imp./kWh[kvarh])

configurationability

500...100010000...100000(dependingonmetertype)(dependingonmetertype)

250...5005000...50000(dependingonmetertype)(dependingonmetertype)aftercertificationbymeansofthecertificationrelevantlogbook

10000...100000(dependingonmetertype)5000...50000(dependingonmetertype)

aftercertificationbymeansofthecertificationrelevantlogbook

Energy registers maximumnumber 32tariffregisters+16tarifflessregisters,eachwith15historicalvalues 32tariffregisters+16tarifflessregisters,eachwith15historicalvaluesMaximum registers maximumnumber

measuringperiod32tariffregisters,eachwith15historicalvalues

1,5,10,15,30,60min,adjustable32tariffregisters,eachwith15historicalvalues

1,5,10,15,30,60min,adjustableLoad profile maximumnumberofchannels

typicalmemorydepthat1channelregisteringperiodregisteringtype

32upto3yearswitharegisteringperiodlengthof15min

1,5,10,15,30,60min,adjustablepower,energy,energyfeed

32upto3yearswitharegisteringperiodlengthof15min

1,5,10,15,30,60min,adjustablepower,energy,energyfeed

Real Time Clock accuracysynchronisationrunningreservebattery/capacitor

within±5ppmviadatainterfaces,controlinputorDCF-module

>20years/approx.6days(150hours)

within±5ppmviadatainterfaces,controlinputorDCF-module

>20years/approx.6days(150hours)Ripple control receiver

numberofchannelstelegrams

6allcommontelegrams

6allcommontelegrams

Control inputs S0-input/systemvoltage max.1/max.5(intotalmax.5inputspossible)

max.2/max.9(intotalmax.10inputspossible)

max.2/max.9(intotalmax.10inputspossible)

Data retention time withoutvoltageintheEEPROM,atleast10years withoutvoltageintheEEPROM,atleast10yearsDisplay displayversion

heightofdigitsalternativedisplay

readingwithoutpowersupply

VDEW-display,84mmx24mm8mm

alphanumericaldisplay4x20characters;70,4mmx20,8mm;heightofdigits4mm

bybufferbattery(optional)

VDEW-display,84mmx24mm8mm

alphanumericaldisplay4x20characters;70,4mmx20,8mm;heightofdigits4mm

bybufferbattery(optional)Operation mechanicalbuttons

opticalsensorforoperationofdisplayandreset(sealableunderhingedmodulecover)

foroperationofdisplayforoperationofdisplayandreset(sealableunderhingedmodulecover)

foroperationofdisplayData interfaces opticaldatainterface

electricaldatainterfacedataprotocolsmaximumtransmissionrate

opticaldatainterfaceD0RS485,RS232orCL0IEC62056-21orDLMS

upto19200baud(fixedorModeC/E)

opticaldatainterfaceD0RS485,RS232orCL0IEC62056-21orDLMS

upto19200baud(fixedorModeC/E)Communication module (plugable)

modeminterfacemoduledataprotocolsmaximumtransmissionrate

GSM/GPRS,Ethernet,PSTN(analog)RS485,RS232

IEC62056-21orDLMSupto19200baud(fixedorModeC/E)

GSM/GPRS,Ethernet,PSTN(analog)RS485,RS232

IEC62056-21orDLMSupto19200baud(fixedorModeC/E)

Outputs maximumnumberOpto-MOSFETS0-outputrelayshighloadrelay

8max.250VAC/DC,100mA(makecontact[NO]orbreakcontact[NC])

max.27VDC,27mAmax.250VAC/DC,100mA(max.2makecontacts[NO])max.250VAC/DC,10A(max.2makecontacts[NO])

8max.250VAC/DC,100mA(makecontact[NO]orbreakcontact[NC])

max.27VDC,27mAmax.250VAC/DC,100mA(max.2makecontacts[NO])max.250VAC/DC,10A(max.2makecontacts[NO])

Energy supply switched-modepowersupplymainsbufferingtime

3-phase>500ms

3-phase>500ms

Auxiliary voltage supply long-range --- 48...300VAC/DC(optional) 48...300VAC/DC(optional) 48...300VAC/DCPower consumption per phase (Basic meter)

voltagepathwithauxiliaryvoltagewithoutauxiliaryvoltagecurrentpathauxiliaryvoltage

---<1,2VA/<0,75W

<0,01VA---

<0,02VA/<0,01W(3x58/100V)<1,2VA/<0,75W

<0,004VA<4,2VA...<2,5VA

<0,02VA/<0,01W(3x58/100V)<1,2VA/<0,75W

<0,004VA<4,2VA...<2,5VA

EMC-characteristics isolationresistancesurgevoltage

resistanceagainstHF-fields

4kVAC,50Hz,1min8kV,impulse1,2/50µs,2Ω(measuringpaths,auxiliaryvoltage)

6kV,impulse1,2/50µs,500Ω(outputs:Opto-MOSFET,relays;inputs:systemvoltage)

10V/m(underload)

4kVAC,50Hz,1min8kV,impulse1,2/50µs,2Ω(measuringpaths,auxiliaryvoltage)

6kV,impulse1,2/50µs,500Ω(outputs:Opto-MOSFET,relays;inputs:systemvoltage)

10V/m(underload)Temperature range specifiedoperatingrange

limitrangeforoperation,storageandtransport

-25°C...+55°C

-40°C...+70°C

-25°C...+55°C

-40°C...+70°CRelative humidity max.95%,non-condensingacc.toIEC62052-11,EN50470-1and

IEC60068-2-30max.95%,non-condensingacc.toIEC62052-11,EN50470-1and

IEC60068-2-30Housing dimensions

classofprotectiondegreeofprotection:housingdegreeofprotection:terminalblockhousingmaterialfirecharacteristics

approx.180x285x80(WxHxD)mm,acc.toDIN43857II

IP51(optionalIP54)IP31

polycarbonateglass-fibrereinforced,withouthalogen,recyclableacc.toIEC62052-11

approx.180x285x80(WxHxD)mm,acc.toDIN43857II

IP51(optionalIP54)IP31

polycarbonateglass-fibrereinforced,withouthalogen,recyclableacc.toIEC62052-11

Environmental conditions

mechanicalelectromagneticintendedlocation

M1acc.toMeasuringInstrumentsDirective(2004/22/EC)E2acc.toMeasuringInstrumentsDirective(2004/22/EC)

indooracc.toEN50470-1

M1acc.toMeasuringInstrumentsDirective(2004/22/EC)E2acc.toMeasuringInstrumentsDirective(2004/22/EC)

indooracc.toEN50470-1Weight 1,4kg 1,2kg 1,2kg

Productspecificationsaresubjecttochangewithoutnotice!

Meters from the series LZQJ-XC are designed foruniversal applications according to VDEW-speci-fications 2.1. Due to the the application of a triedand tested measuring procedure the meter isdistinguishedby itshighreliability.Thehighperfor-mingprocessorsystemguaranteesasolidbasisforfurtherextensions.

TheLZQJ-XCfunctionscanbeextentedwiththefollowingaccessories:

MetermodemVARIOMOD-XC(GSM/GPRS,Ethernet,PSTN)

Interfacemodule(RS232,RS485)

DCF-AerialDCF77-TH2

OpticalfibreseparationboxLTR

Communicationandparameterisationsoftware

Networkanalysis(optional)


Recommended