LZQJ-XCAdditional features of the LZQJ-XC:

Measuringofinstantaneous P,Q,S(perphaseandsum),U,I,powerfactor,linefrequency, valuesphasefailuresInstallationcheck viainstantaneousvalues(servicedata)possibleOpticalfibreinterface forconnectionofupto4opticalfibreseparationboxesBufferbattery exchangeablebufferbatteryforreadingoutthemeterviatheopticalinterface andreadingthedisplaywithoutpowerTamperdetection openingofmeterandterminalcoverandmagneticfieldsNetworkanalysis monitoringofU,I,THD,f,flicker,harmonicsacc.toDINEN50160

The LZQJ-XC fulfils the following standards:

DIN43857-2 Watthourmetersinmouldedinsulationcasewithoutinstrumenttransformers, upto60Aratedmaximumcurrent;principaldimensionsforpoly-phasemetersEN50470-1 Electricitymeteringequipment(a.c.)-Part1:Generalrequirements, estsandtestconditions-Meteringequipment(classindexesA,BandC)EN50470-3 Electricitymeteringequipment(a.c.)-Part3:Particularrequirements- Staticmetersforactiveenergy(classindexesA,BandC)IEC61000-... Electromagneticcompatibility(EMC)IEC60529 Degreesofprotectionprovidedbyenclosures(IPcode)IEC61038 TimeswitchesfortariffandloadcontrolIEC62052-11 Electricitymeteringequipment(AC)-Generalrequirements, testsandtestconditions-Part11:MeteringequipmentIEC62053-21 Electricitymeteringequipment(a.c.)-ParticularRequirements -Part21:Staticmetersforactiveenergy(classes1and2)IEC62053-22 Electricitymeteringequipment(a.c.)-Particularrequirements -Part22:Staticmetersforactiveenergy(classes0,2Sand0,5S)IEC62053-23 Electricitymeteringequipment(a.c.)-Particularrequirements -Part23:Staticmetersforreactiveenergy(classes2and3)IEC62056-21 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part21:DirectlocaldataexchangeIEC62056-46 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part46:DatalinklayerusingHDLCprotocolIEC62056-53 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part53:COSEMapplicationlayerIEC62056-61 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part61:Objectidentificationsystem(OBIS)IEC62056-62 Electricitymetering-Dataexchangeformeterreading,tariffandloadcontrol -Part62:InterfaceclassesDIN66348-1 Interfacesandbasicdatalinkcontrolproceduresforserialmeasurement datacommunication;start-stop-transmission,point-to-pointconnectionITU-TV.11 Electricalcharacteristicsforbalanceddouble-currentinterchangecircuits operatingatdatasignallingratesupto10Mbit/sTIA/EIA-485 Electricalcharacteristicsofgenerators&receiversforuseinbalanceddigital multipointsystemsITU-TV.24 Listofdefinitionsforinterchangecircuitsbetweendataterminalequipment(DTE) anddatacircuit-terminatingequipment(DCE)ITU-TV.28 Electricalcharacteristicsforunbalanceddouble-currentinterchangecircuits

Page 2: Additional features of the LZQJ-XC: LZQJ-XC · EN EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-mail info@emh-metering.com

Direct connection version5(60) A, 10(60) A, 5(100) A, 10(100) A

Transformer connection versionCl. B (Cl. 1)

Precision MeterCl. C (Cl. 0,5 S)

Precision MeterCl. 0,2 S

Voltage 4-wiremeter

3-wiremeter

2-wiremeter(for16,7Hz)

3x127/220V...3x240/415V

---

---

3x58/100V...3x240/415V(optional3x57,7/100...3x277/480V)

orupto3x400/690V3x100V...3x415Vorupto3x690V100V...240V

3x58/100V...3x240/415V(optional3x57,7/100...3x277/480V)

orupto3x400/690V3x100V...3x415Vorupto3x690V100V...240V

Current 5(60)A,10(60)A,5(100)A,10(100)A 5||1A,1(6)A,1(10)A,5A,1A,5(20)A 5||1A,1(6)A,1(10)A,5A,1A,5(20)AFrequency 50Hz,60Hz 50Hz,60Hz,16,7Hz 50Hz,60Hz,16,7HzAccuracy activeenergy

reactiveenergyCl.A(Cl.2),optionalCl.B(Cl.1)

Cl.3,optionalCl.2Cl.B(Cl.1)

Cl.2Cl.C(Cl.0,5S)1%(Cl.2)

Cl.0,2S0,5%(Cl.2)

Measuring system designation compensatedcurrenttransformer compensatedcurrenttransformerMeasuring types activeenergy

reactiveenergyothers

+A,-A+R,-R,R1,R2,R3,R4

S,Ah,U2h,I2h

+A,-A+R,-R,R1,R2,R3,R4

S,Ah,U2h,I2hMeter constants LED(Imp./kWh[kvarh])

output(Imp./kWh[kvarh])

configurationability

500...100010000...100000(dependingonmetertype)(dependingonmetertype)

250...5005000...50000(dependingonmetertype)(dependingonmetertype)aftercertificationbymeansofthecertificationrelevantlogbook

10000...100000(dependingonmetertype)5000...50000(dependingonmetertype)

aftercertificationbymeansofthecertificationrelevantlogbook

Energy registers maximumnumber 32tariffregisters+16tarifflessregisters,eachwith15historicalvalues 32tariffregisters+16tarifflessregisters,eachwith15historicalvaluesMaximum registers maximumnumber

measuringperiod32tariffregisters,eachwith15historicalvalues

1,5,10,15,30,60min,adjustable32tariffregisters,eachwith15historicalvalues

1,5,10,15,30,60min,adjustableLoad profile maximumnumberofchannels

typicalmemorydepthat1channelregisteringperiodregisteringtype

32upto3yearswitharegisteringperiodlengthof15min

1,5,10,15,30,60min,adjustablepower,energy,energyfeed

32upto3yearswitharegisteringperiodlengthof15min

1,5,10,15,30,60min,adjustablepower,energy,energyfeed

Real Time Clock accuracysynchronisationrunningreservebattery/capacitor

within±5ppmviadatainterfaces,controlinputorDCF-module

>20years/approx.6days(150hours)

within±5ppmviadatainterfaces,controlinputorDCF-module

>20years/approx.6days(150hours)Ripple control receiver

numberofchannelstelegrams

6allcommontelegrams

6allcommontelegrams

Control inputs S0-input/systemvoltage max.1/max.5(intotalmax.5inputspossible)

max.2/max.9(intotalmax.10inputspossible)

max.2/max.9(intotalmax.10inputspossible)

Data retention time withoutvoltageintheEEPROM,atleast10years withoutvoltageintheEEPROM,atleast10yearsDisplay displayversion

heightofdigitsalternativedisplay

readingwithoutpowersupply

VDEW-display,84mmx24mm8mm

alphanumericaldisplay4x20characters;70,4mmx20,8mm;heightofdigits4mm

bybufferbattery(optional)

VDEW-display,84mmx24mm8mm

alphanumericaldisplay4x20characters;70,4mmx20,8mm;heightofdigits4mm

bybufferbattery(optional)Operation mechanicalbuttons

opticalsensorforoperationofdisplayandreset(sealableunderhingedmodulecover)

foroperationofdisplayforoperationofdisplayandreset(sealableunderhingedmodulecover)

foroperationofdisplayData interfaces opticaldatainterface

electricaldatainterfacedataprotocolsmaximumtransmissionrate

opticaldatainterfaceD0RS485,RS232orCL0IEC62056-21orDLMS

upto19200baud(fixedorModeC/E)

opticaldatainterfaceD0RS485,RS232orCL0IEC62056-21orDLMS

upto19200baud(fixedorModeC/E)Communication module (plugable)

modeminterfacemoduledataprotocolsmaximumtransmissionrate

GSM/GPRS,Ethernet,PSTN(analog)RS485,RS232

IEC62056-21orDLMSupto19200baud(fixedorModeC/E)

GSM/GPRS,Ethernet,PSTN(analog)RS485,RS232

IEC62056-21orDLMSupto19200baud(fixedorModeC/E)

Outputs maximumnumberOpto-MOSFETS0-outputrelayshighloadrelay

8max.250VAC/DC,100mA(makecontact[NO]orbreakcontact[NC])

max.27VDC,27mAmax.250VAC/DC,100mA(max.2makecontacts[NO])max.250VAC/DC,10A(max.2makecontacts[NO])

8max.250VAC/DC,100mA(makecontact[NO]orbreakcontact[NC])

max.27VDC,27mAmax.250VAC/DC,100mA(max.2makecontacts[NO])max.250VAC/DC,10A(max.2makecontacts[NO])

Energy supply switched-modepowersupplymainsbufferingtime

3-phase>500ms

3-phase>500ms

Auxiliary voltage supply long-range --- 48...300VAC/DC(optional) 48...300VAC/DC(optional) 48...300VAC/DCPower consumption per phase (Basic meter)

voltagepathwithauxiliaryvoltagewithoutauxiliaryvoltagecurrentpathauxiliaryvoltage

---<1,2VA/<0,75W

<0,01VA---

<0,02VA/<0,01W(3x58/100V)<1,2VA/<0,75W

<0,004VA<4,2VA...<2,5VA

<0,02VA/<0,01W(3x58/100V)<1,2VA/<0,75W

<0,004VA<4,2VA...<2,5VA

EMC-characteristics isolationresistancesurgevoltage

resistanceagainstHF-fields

4kVAC,50Hz,1min8kV,impulse1,2/50µs,2Ω(measuringpaths,auxiliaryvoltage)

6kV,impulse1,2/50µs,500Ω(outputs:Opto-MOSFET,relays;inputs:systemvoltage)

10V/m(underload)

4kVAC,50Hz,1min8kV,impulse1,2/50µs,2Ω(measuringpaths,auxiliaryvoltage)

6kV,impulse1,2/50µs,500Ω(outputs:Opto-MOSFET,relays;inputs:systemvoltage)

10V/m(underload)Temperature range specifiedoperatingrange

limitrangeforoperation,storageandtransport

-25°C...+55°C

-40°C...+70°C

-25°C...+55°C

-40°C...+70°CRelative humidity max.95%,non-condensingacc.toIEC62052-11,EN50470-1and

IEC60068-2-30max.95%,non-condensingacc.toIEC62052-11,EN50470-1and

IEC60068-2-30Housing dimensions

classofprotectiondegreeofprotection:housingdegreeofprotection:terminalblockhousingmaterialfirecharacteristics

approx.180x285x80(WxHxD)mm,acc.toDIN43857II

IP51(optionalIP54)IP31

polycarbonateglass-fibrereinforced,withouthalogen,recyclableacc.toIEC62052-11

approx.180x285x80(WxHxD)mm,acc.toDIN43857II

IP51(optionalIP54)IP31

polycarbonateglass-fibrereinforced,withouthalogen,recyclableacc.toIEC62052-11

Environmental conditions

mechanicalelectromagneticintendedlocation

M1acc.toMeasuringInstrumentsDirective(2004/22/EC)E2acc.toMeasuringInstrumentsDirective(2004/22/EC)

indooracc.toEN50470-1

M1acc.toMeasuringInstrumentsDirective(2004/22/EC)E2acc.toMeasuringInstrumentsDirective(2004/22/EC)

indooracc.toEN50470-1Weight 1,4kg 1,2kg 1,2kg

Productspecificationsaresubjecttochangewithoutnotice!

Meters from the series LZQJ-XC are designed foruniversal applications according to VDEW-speci-fications 2.1. Due to the the application of a triedand tested measuring procedure the meter isdistinguishedby itshighreliability.Thehighperfor-mingprocessorsystemguaranteesasolidbasisforfurtherextensions.

TheLZQJ-XCfunctionscanbeextentedwiththefollowingaccessories:

MetermodemVARIOMOD-XC(GSM/GPRS,Ethernet,PSTN)

Interfacemodule(RS232,RS485)

DCF-AerialDCF77-TH2

OpticalfibreseparationboxLTR

Communicationandparameterisationsoftware

Networkanalysis(optional)


Top Related