36
(en) Operating instructions 8068814 1701g [8068816] Adsorption dryer PDAD
Transcript
Page 1: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

(en) Operating instructions

80688141701g[8068816]

Adsorption dryer

PDAD

Page 2: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

2 | Festo PDAD 1701g

Original instructions

Installation and commissioning are to be carried out only by qualified personnel in accordance with the operating instructions.

Page 3: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 3

Table of contents

1. Introduction .................................................................................................................. 4

2. Safety ............................................................................................................................ 5

3. Component designation ................................................................................................ 73.1 Overview ....................................................................................................................... 73.2 Electronic controller 2 ................................................................................................ 93.3 Multiple distributor aJ ................................................................................................ 93.4 Desiccant cartridge with integrated dust filter 9 ........................................................ 93.5 Reservoir 7 ................................................................................................................. 9

4. Function ...................................................................................................................... 10

5. Installation .................................................................................................................. 115.1 Mounting the micro filter on the dryer ........................................................................ 115.2 Pneumatic connection ................................................................................................. 135.3 Assembling the mounting accessories on the dryer .................................................... 145.4 Changing the connections for the inlet and outlet ...................................................... 155.5 Installation conditions ................................................................................................ 16

6. Power supply .............................................................................................................. 176.1 Voltage connection ..................................................................................................... 176.2 Power supply socket connection ................................................................................. 186.3 Alarm connection ........................................................................................................ 19

7. Commissioning ........................................................................................................... 20

8. Maintenance and care ................................................................................................. 228.1 LED displays ................................................................................................................ 228.2 Decommissioning for maintenance purposes ............................................................. 248.3 Maintenance and service ............................................................................................ 248.4 Removing/installing the front or rear cover ................................................................ 258.5 Replacing or cleaning the air nozzle ............................................................................ 268.6 Cleaning the silencer ................................................................................................... 278.7 Resetting the controller .............................................................................................. 28

9. Troubleshooting .......................................................................................................... 299.1 General fault finding ................................................................................................... 299.2 Electrical troubleshooting ........................................................................................... 30

10. Accessories ................................................................................................................. 31

11. Technical data ............................................................................................................. 32

Page 4: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

4 | Festo PDAD 1701g English

1. Introduction

For all available product documentation www.festo.com/pk

The product described in these operating instructions may only be installed, operated and maintained if these operating instructions have been completely read and understood by the employees handling the product.

These operating instructions and in particular the safety instructions are to be kept with the product or as a print-out or copy. The operating instructions must be strictly adhered to.

Please keep the following information available if you need to contact Festo with regard to the product or the operating instructions.

• Part number and type designation

• Date commissioned

The part number and type designation can be found on the rating plate on the top right-hand side of the device. Please note this information in the operating instructions as a reminder and for future use.

The dryer is delivered in protective packaging. Use due diligence when transporting, loading and unloading the device.

On delivery, the dryer is configured with an air nozzle for an operating pressure of 7 to 9 bar. You must ensure that the correct air nozzle is attached for the anticipated operating pressure. For more information see the table with technical data in chapter 11.

Scope of delivery

Adsorption dryer PDAD

Micro filter MS6-LFM

Adapter kit Power supply socket

Tubing Operating instructions PDAD

Page 5: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 5

2. Safety

Festo expressly excludes any liability or responsibility for damages and/or injuries which result from violation of these operating instructions.

The device may only be used for its intended purpose. The cold regenerative adsorption dryer is only to be used according to its intended purpose for drying pressurised air under the conditions described in chapter 11 of these operating instructions. Any other use of the device is considered not for its intended purpose. Festo is not liable for damages which result from misuse.

The following symbols indicate a possible hazard. Where such hazards arise, the appropriate measures must be taken in order to reduce the risk for the user or operator of the product.

Caution:

Source of danger

Attention:

Danger due to electrical voltage

Attention:

Danger due to high pressures

Note on Pressure Equipment Directive

Classification of the dryers in pressure equipment categories

Category

Type

I

PDAD-09

I

PDAD-13

I

PDAD-22

I

PDAD-51

II

PDAD-73

II

PDAD-100

Notes on commissioning and maintenance

Vibrations can cause fatigue in the material and can decrease the endurance limit of the adsorption dryers and mounting components.

• Protect adsorption dryers and mounting components against mechanical vibrations.

Commissioning and the intervals for periodic inspections are subject to the applicable national regulations.

When carrying out maintenance work, inspect components visually for damage. Replace the device if necessary.

Page 6: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

6 | Festo PDAD 1701g English

The following safety regulations need to be strictly adhered to:

• These operating instructions or a print-out or copy thereof are to be left at the place where the product is installed.

• Repair work on the device is only to be carried out by personnel authorised by Festo.

• Operating, repair and maintenance personnel must be aware of the following information:

– Accident prevention regulations

– Safety information (general and device specific)

– Device safety equipment

– Measures to be taken in an emergency

• It is the installer's responsibility to ensure that the cables to and from the dryer are suitable for the task, correspond to the applicable laws and have been subjected to a visual check and tests before commissioning. All cables must be fitted in an appropriate manner.

• The device must be decommissioned before carrying out any maintenance or repair work. Operators and other personnel are exposed to a risk if work is carried out on a running device. Decommissioning the device means disconnecting it from the power supply and compressed air supply, and ensuring the pressure is completely reduced.

• Only trained specialists who are aware of the electrical requirements of the device as described in these operating instructions as well as the safety regulations and conditions are permitted to carry out work on the electrical components and the power supply of the device.

• Use suitable, correctly sized tools that are in good condition to carry out any work on the device.

• Only use accessories and spare parts from the manufacturer. There is no guarantee that non-original spare parts are designed and manufactured to correspond to the safety and operating requirements of the device. Festo takes no liability for device faults which result from the use of unapproved spare parts.

• Use suitable and safe work platforms or other secure work access options to carry out installation work above head height.

• Do not make any design changes to the product. Changes and modifications may only be carried out by Festo.

• All faults or defects which could impair safety must be eliminated before using the device.

• Used objects and materials must be correctly disposed of in line with the local laws and conditions. This applies in particular to the desiccant cartridges.

Page 7: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 7

3. Component designation

On the back of the dryer

ad

1 Upper valve block

2 Electronic controller

3 Lower valve block

4 Floor plate

5 Front cover

6 Mounting screw front cover

7 Reservoir

8 Mounting screw reservoir

9 Desiccant cartridge with integrated dust filter

aJ Multiple distributor

aA Cover plate

aB Cover plate mounting screw

aC Rear cover

aD Power supply socket

aE Reservoir seal screw

aF Seal

aG Silencer

aH Air nozzle

aB aHaJ aA

1

aC

8

7

9

3

aG

5

6

2

aF

4

aE

3.1 Overview

The figure below shows the main components of the dryer PDAD-09/13/22/51/73 .

Page 8: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

8 | Festo PDAD 1701g English

On the inside of the dryer

ad

1 Upper valve block

2 Electronic controller

3 Lower valve block

4 Floor plate

5 Front cover

6 Mounting screw front cover

7 Reservoir

8 Mounting screw reservoir

9 Desiccant cartridge with integrated dust filter

aJ Multiple distributor

aA Cover plate

aB Cover plate mounting screw

aC Rear cover with cable throughfeed for mains connection

aD Power supply socket

aE Reservoir seal screw

aF Seal

aG Silencer

aH Air nozzle

aI Multiple distributor connection screws

bJ Seal for connecting multiple distributor

The figure below shows the main components of the dryer PDAD-100.

aB aH

aJ

aAaI

1

aC

8

7

9

3

5

6

4

2

aG

aF

aE bJ

Page 9: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 9

3.2 Electronic controller 2

The valve blocks (on top and below) are actuated by solenoid valves in the controller which determine the pressure and direction of the air flow in the desiccant cartridge.

3.3 Multiple distributor aJ

The standard design of the dryer is configured in such a way that the inlet openings are on the left and the outlet openings on the right when looking at the front of the device. By using the opening nozzles several different opening requirements become available. See also section 5.4.

Inlet

See the direction of the arrows for inlet side of the dryer

Outlet

Installation in corners

3.4 Desiccant cartridge with integrated dust filter 9

The desiccant cartridges contain a drying agent which has been developed for drying compressed air. The drying agent is contained in a transparent tube with end pieces which allow the air to flow through at both ends. In the upper part of each cartridge is a 1 micron filter to separate residual dust from the drying agent. The cartridge length varies with the rated output of the dryer.

3.5 Reservoir 7

The desiccant cartridge is located in an extruded aluminium reservoir and has pressurised end caps. The operating pressure and the flow through the individual cartridges is controlled by the valve blocks positioned between the two reservoirs. The regenerative air flow (purge air flow) is controlled by an external air nozzle with a small opening (front, central) on the upper valve block, accessible by removing the cover.

Page 10: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

10 | Festo PDAD 1701g English

4. Function

During dry operation an even, uninterrupted supply of compressed air should be provided according to the specification.

This function is achieved with two compressed air reservoirs which operate in alternating cycles. If air is being dried in one reservoir, the drying agent in the second reservoir can regenerate.

In the adsorption dryer the main air flow is fed through the desiccant cartridge(s) of a reservoir. This removes the moisture so the required pressure dew point can be achieved. A small amount of the dry air (purge air) is fed to the other reservoir. The purge air flows through the desiccant cartridge(s), escapes into the atmosphere through a drain valve and thus regenerates the drying agent.

The regeneration cycle lasts 120 seconds. The corresponding drain valve is then closed. This means the regenerated reservoir can be brought up to system pressure with the purge air and can switch to the operating cycle. After a further 50 seconds the other reservoir starts a new regenerative operating cycle.

Page 11: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 11

In order to protect the drying agent from contaminated pressurised air the micro filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow). If an inlet on the right-hand side is required the multiple distributor in the cover of the dryer must be turned (see chapter 5.4).

1. Select an inlet opening. Remove any sealing plugs and attach them to the unused inlet.

2. Insert a lightly greased O-ring 2 in the slot of inlet 1.

3. Fit the module connecting plate 3 with hollow bolt 4 with spanner size 10 (for PDAD-...y) or max. 14 Nm (for PDAD-...½). The maximum tightening torque is 15 Nm (for PDAD-...y) or max 18 Nm (for PDAD-...½). The module connecting plate 3 can be adjusted 90° for horizontal instal-lation of the dryer.

5. Installation

5.1 Mounting the micro filter on the dryer

1

2

3

3

4

Page 12: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

12 | Festo PDAD 1701g English

4. Insert flat seal 5 in the slot of the module connecting plate 3 and O-ring 6 in the slot of micro filter MS 6-LFM.

5. Position micro filter MS6-LFM on the dryer. Observe the direction of flow from 1 to 2. The number 7 on the product housing serves as a guide.

6. Place module connector 8 between the micro filter MS6-LFM and the dryer and then fit it using two screws. The prominent edge of the modu-le connector should be pointing upwards. The tightening torque of the screws is 1.2 Nm ±10%.

7. Connect the supplied 4 mm tubing 9 (outside diameter) to the condensate drain of the micro filter. Connect the other end of the tubing with the screw QSL-F on the back of the dryer (upper connection 'condensate inlet').

8. Connect the tubing with 4 mm diame-ter (outside diameter) to screw QSL-F on the back of the dryer (lower con-nection 'condensate outlet'). Connect the other end of the tubing with suita-ble condensate collecting bowls.

8

9

5

3

6

7

Page 13: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 13

1

Note

The micro filter MS6-LFM must be placed vertically (±5°) regardless of the installation location of the dryer. Check that there is sufficient space below the filter bowl (min. 100 mm). When installing horizontally, support with suitable material.

5.2 Pneumatic connection

1. Turn the connection screw or piping into the threaded connection of the micro filter MS6-LFM. Note the screw-in depth of the threaded connection:

2. Turn the connection screw or pipeline into the outlet of the dryer.

Adapter assembly (only for PDAD-...-N...):

Turn the NPT adapter supplied 1 with sealing ring into the outlet of the dryer. The maximum tightening torque is 15 Nm (for PDAD-...N3/8) or max 18 Nm (for PDAD-...½).

Type

Max. screw-in depth [mm]

ISO 228

MS6(N)-LFM 12.0

(NPT)

10.3

Page 14: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

14 | Festo PDAD 1701g English

Note

It is recommended that you install a by-pass line around the dryer and the prefilter.

Note

The mounting accessories are not in the scope of the delivery of the adsorption dryer PDAD. These parts must be ordered separately.

O B

C D

Wall mounting ABMW-PDAD Foot mounting ABMF-PDAD

The maximum tightening torque is 10 Nm.

Note:

It is not possible to mount the micro filter MS6-LFM on the inlet on the back of the dryer.

The maximum tightening torque is 10 Nm.

5.3 Assembling the mounting accessories on the dryer

Page 15: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 15

5.4 Changing the connections for the inlet and outlet

1. Delivery state: three inlet options on the left-hand side of the dryer (viewed from the front).

5. Dryer after removing the multiple distributor.

Inlet

Outlet

2. Loosen both mounting screws (PZ 2) from the cover and remove the cover.

6. Turn the multiple distributor 180° and reinstall it with the help of the four mounting screws (max. tightening torque 20 Nm). Make sure both O-rings are properly seated.

3. Dryer after removing the cover 4. Release the four mounting screws of the multiple distributor (SW 5) and remove the multiple distributor.

7. Reinstall the cover using both mounting screws (max. tightening torque 1 Nm).

8. Location of the connections for the inlet and outlet after carrying out the steps described.

Inlet

Outlet

Page 16: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

16 | Festo PDAD 1701g English

5.5 Installation conditions

Correct Incorrect Correct Incorrect

The dryer is designed for safe operation under the following conditions:

• Use indoors

• Height of up to 2,000 m

• Maximum relative air humidity 80% for temperatures up to 31 °C declining in a linear fashion to 50% at 40 °C

Page 17: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 17

6. Power supply

6.1 Voltage connection

1. The dryer can be operated with alternating current (AC) or direct current (DC).

Make sure that only one power source is connected to the correct socket. The cover supplied must then be attached to the unoccupied power supply, see chapter 6.2.

A power source connected to the wrong power supply can destroy the electronics!

2. The power supply is provided using the power connection socket supplied.

Voltage Current intensity

12 V DC

24 V DC

100 V AC

115 V AC

230 V AC

240 V AC

0.8 A

0.4 A

0.16 A

0.14 A

0.07 A

0.067 A

3. The dryer is isolated for protection and therefore does not require earthing.

4. A suitable external fuse must be used.

5. The cable used must correspond to the local installation conditions as well as the power consumption.

Seal

1 (+) Phase

2 (–) Earthed conductor

Page 18: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

18 | Festo PDAD 1701g English

6.2 Power supply socket connection

Voltage: 100 to 240 V AC

Cover

Voltage: 12 to 24 V AC

Cover

Note

The connections for the network socket on the PDAD-100 are on the bottom behind the cover. These can be removed after unfastening the mounting screw (SW 5), see chapter 8.4.

Page 19: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 19

6.3 Alarm connection

The electronic controller has an alarm relay with DIN connection. A visual or acoustic remote alarm system can be connected outside the dryer with this DIN connection.

In the event of a fault or when servicing is required the alarm relay switches. At the same time, red LEDs on the display panel show the fault which has occurred, see chapter 8.1.

When the fault is eliminated, the alarm relay resets, but only after the current switching cycle has finished or the control device has been reset after a cartridge change.

In order to set up the remote alarm system a suitable cable must be fed through a rubber grommet in the rear wall for electronic control.

1. Connect the switching pin of an alarm installation with the external power supply to pins 1 and 2 of the DIN plug.

2. Remove the cover from the DIN connection marked 'Alarm' as described in number 1 while the power supply to the dryer is interrupted and connect the wired DIN con-nection. Make sure that the seal and screw are inserted correctly.

– Socket MSSD-E (Festo part no. 14098)

– Hirschmann GDS 207

Alarm relay current intensity Plug for DIN connection

Max. 3 A, 28 V DC

External power supply

Page 20: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

20 | Festo PDAD 1701g English

On delivery, the adsorption dryer is configured with an air nozzle for an operating pressure of 7 to 9 bar. The air nozzle must be changed for other operating pressures. The set with the remaining air nozzles is not part of the scope of delivery and must be ordered separately, see Accessories (chapter 10, see also www.festo.com/sp). Each air nozzle is engraved with a number for identification purposes.

1. Determine the suitable air nozzle for the anticipated operating pressure using the table with technical data in chapter 11.

2. If necessary, replace the air nozzle in the dryer. To do this, follow the steps in chapter 8.4 and chapter 8.5

1. Close valves A, B, C and D.

2. Switch on the compressor.

3. Slowly open valve A. Compressed air flows through the desiccant cartridge and escapes into the atmosphere via the silen-cer.

4. Check the dryer for leaks.

C D

O B

7. Commissioning

Page 21: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 21

5. Switch on the power supply. All four LEDs on the display panel simultaneously flash green four times and then red four times to confirm the power supply. The device is then ready for operation. Observe the display panel during an entire operating cycle. The following cycle is preset in the factory and starts automatically.

(i) The power supply LED POWER and the reservoir LED X light up green.

(ii) After 120 seconds the reservoir LED X goes out and the condensate drain LED Z lights up green. The condensate drain valve opens for approx. 2 seconds.

(iii) After a further 50 seconds the condensate drain LED Z goes out and the reservoir LED Y lights up green.

(iv) After a further 120 seconds the reservoir LED Y goes out.

(v) After a further 50 seconds the reservoir LED X lights up green.

(vi) The cycle described above repeats itself (i – v).

6. Reset the control device using the reset disc from the service package (not during initial commissioning – see chapter 8.7 „Resetting the controller“)

7. Leave the dryer to run for at least 6 hours in order to ensure that the correct pressure dew point is reached.

8. Slowly open valve B.

Z

X Y

POWER

Z

x Y

POWER

Page 22: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

22 | Festo PDAD 1701g English

8. Maintenance and care

OK

Warning

8.1 LED displays

Status LED colours and signals Description

Operating voltage off –

Cycle regeneration left reservoir

End of regeneration left reservoir and condensate drain

Cycle regeneration right reservoir

Right reservoir end of regeneration

Report (upcoming maintenance) after every 11,500 hours of operation

Order service package with new desiccant cartridge.

Action

Page 23: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 23

Service required

Status LED colours and signals Description

Maintenance interval after every 12,000 hours of operation

Replace desiccant cartridge, see assembly instructions service package PDAD.

Fault in right solenoid valve

Take device out of operation and contact a Festo service technician.

Fault in left solenoid valve Take device out of operation and contact a Festo service technician.

Fault in condensate drain valve

Take device out of operation and contact a Festo service technician.

Fault in control device Take device out of operation and contact a Festo service technician.

Fault in power supply Check power supply.

Action

Page 24: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

24 | Festo PDAD 1701g English

C D

O B

8.2 Decommissioning for maintenance purposes

1. If a bypass line has been installed, open valve C and D. Make sure that the air flowing through the bypass is not dried out.

2. Close valve B.

3. Close valve A.

4. Leave the dryer to run for 15 minutes to ensure the pressure is completely reduced.

5. Disconnect the device from all power supplies.

The desiccant cartridges can fail.

• Ensure that there is no compressed air in the adsorption dryer during longer interruptions to the power supply.

8.3 Maintenance and service

Before any maintenance work, the dryer must be decommissioned, seechapter 8.2.

The following maintenance tasks must be carried out by the user of the dryer:

• After every 12,000 operating hours: change the desiccant cartridges (see chapter 8.4) with the parts from the service package. The service package is to be ordered separately and contains the desiccant cartridges, O-rings, a reset disc and instructions.

• As required: clean the air nozzle (see chapter 8.5) or the silencer (see chapter 8.6).

Page 25: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 25

8.4 Removing/installing the front or rear cover

1. Dryer with mounted cover plate.

4. Dryers without covers.

2. Remove the mounting screw (SW5).

3. Pull the cover outwards and remove it by pushing it downwards.

5. Insert the cover, placing the insertion springs on the cover into the groove of the dryer. Then push the cover upwards and press it inwards.

6. Re-attach the mounting screw (max tightening torque 1 Nm).

Page 26: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

26 | Festo PDAD 1701g English

8.5 Replacing or cleaning the air nozzle

1. Remove the front and rear dryer covers (only for PDAD-100, see chapter 8.4. The air nozzle is in the upper valve block.

2. Remove the air nozzle mounting screw (PZ 2).

3. Pull the air nozzle out of the opening of the upper valve block.

4. Only when cleaning: clean the air nozzle with warm, soapy water. Then dry it thoroughly. Do not use any sharp aids or tools.

5. Push the replacement or cleaned air nozzle into the valve block. Ensure that the O-rings are in good condition and in the correct places.

6. Insert the mounting screw of the air nozzle back into the upper valve block and tighten it.

Page 27: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 27

1. Remove front and rear (only for PDAD-100) cover of the dryer; see chapter 8.5.

2. Disconnect silencer from valve block.

3. Remove silencer from dryer. 4. Clean threads on silencer.

8.6 Cleaning the silencer

5. Silencer can be thoroughly cleaned in warm soapy water. Do not use sharp instruments or tools.

6. Ensure silencer is thoroughly clean and dry then replace by following the above procedure in reverse.

Page 28: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

28 | Festo PDAD 1701g English

8.7 Resetting the controller

1. If the dryer is put into operation again after a cartridge has been replaced, the con-troller must be reset using the reset disc in the service package.

2. The disc must be held for five seconds on the blue part of the display.

3. During these five seconds the power supply LED POWER (network supply) flashes green. After a successful reset, the reservoir LED Y flashes red once as confirmation.

2

1

1 Reservoir LED Y

2. Power LED

Page 29: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 29

9. Troubleshooting

9.1 General fault finding

Before searching for a specific fault, the following general questions must be clarified:

• Has the device been externally damaged or are parts of the device missing?

• Is the device supplied with power?

• Was commissioning carried out as described in these operating instructions?

• Are all the external valves for drying set correctly?

• Do the current operating conditions correspond to the operating conditions when the product was selected and ordered?

The possible causes and actions for possible faults with the dryer are listed in the table below:

Jammed shuttle valve or faulty electric components

Problem Possible cause Actions

Bad dew point

Functional fault

Water at dryer inlet Check prefiltering and condensate drain

Air flow is too high Compare actual air flow with the highest indicated air flow

Inlet pressure is too low Compare to the value indicated

Inlet temperature too high Compare to the value indicated

Silencer blocked or damaged

Clean or replace silencer

Leakage Tighten connection points or replace seals

See section about electrical troubleshooting

Page 30: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

30 | Festo PDAD 1701g English

9.2 Electrical troubleshooting

(see also LED displays in chapter 8.1)

Problem Possible cause Display Priority Actions

No dry operation

No power supply None – Check supply

Faulty dry operation

Short-circuit or cable interruption, left solenoid valve

Reservoir LED X flashing red

P1 Take device out of operation and contact a Festo service technician.

Short-circuit or cable interruption, right solenoid valve

Reservoir LED Y flashing red

P1 Take device out of operation and contact a Festo service technician.

Controller fault Power supply LED POWER flashing red

P2 Take device out of operation and contact a Festo service technician.

Faulty power supply

Power supply LED POWER continuously lights up red

P1 Check supply

Drain not switched on

Solenoid drain valve open or short circuit

Condensate drain LED Z flashing red

P1

P2

Take device out of operation and contact a Festo service technician.

Controller fault Power supply LED POWER flashing red

Take device out of operation and contact a Festo service technician.

Page 31: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 31

10. Accessories

Accessories Service package with desiccant cartridges, O-rings, reset disc and manual

Air nozzle set with 3 air nozzles (PDAD-100: 6 air nozzles)

For PDAD-09 PDAD-09-SP-12000 ADNA-PDAD-09

For PDAD-13 PDAD-13-SP-12000 ADNA-PDAD-13

For PDAD-22 PDAD-22-SP-12000 ADNA-PDAD-22

For PDAD-51 PDAD-51-SP-12000 ADNA-PDAD-51

For PDAD-73 PDAD-73-SP-12000 ADNA-PDAD-73

For PDAD-100 PDAD-100-SP-12000 ADNA-PDAD-100

Page 32: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

32 | Festo PDAD 1701g English

11. Technical data

1) Without prefilter

Type PDAD-09 PDAD-13 PDAD-22 PDAD-51 PDAD-73 PDAD-100

Operating pressure

[bar] 4 … 16

Operating medium

Compressed air to ISO 8573-1:2010 [6:4:4],

Degree of protection

Drying agent

IP65 (as per EN 60529)

Zeolite, Na2O . Al2O3 . 2.5 SiO2 . n H2O

Desiccant lifetime 12,000 operating hours

Mounting position

Vertical

Horizontal

[°C]Ambient temperature

+5 … +50

[°C]Temperature of medium

+2 … +50

Pressure dew point

[°C] –40

[°C] –70 (with reduced flow rate)

Operating voltage range

[V DC] 8 … 26.4

Power consumption

CE marking, Declaration of

conformity www.festo.com/sp

[V AC] 90 … 264 (50 … 60 Hz)

For DC: approx. 9.6 W (24 V/0.4 A type) For AC: approx. 16 VA (230 V/0.07 A type)

According to EMV guidelines According to low voltage guidelines According to pressurised device guidelines

Air quality class at the outlet port

Compressed air to ISO 8573-1:2010 [2:1:2] at pressure dew point –70°

Compressed air to ISO 8573-1:2010 [2:2:2] at pressure dew point –40°

Product weight [kg] 13 14 16.5 24 31 47

Width1) [mm] 281 281 281 281 281 281

Depth1) [mm] 92 92 92 92 92 184

Internal volume [l] 4.2 4.6 6.0 11.0 15.8 22.0

Height1) [mm] 445 504 635 1 065 1 460 1 065

Page 33: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 33

PDAD-09 PDAD-13 PDAD-22 PDAD-51 PDAD-73 PDAD-100

Operating pressure p [bar]

Nominal flow rate for –40 °C pressure dew point (inlet temperature 25 °C saturated)

4 73.6 33.0 40.6

109.6 42.0 67.6

186.2 76.0

110.2

416.3 166.0 250.3

613.5 233.0 380.5

821.7 332.0 489.7

5 88.3 30.0 58.3

132.5 52.0 80.5

225.3 89.0

136.3

503.6 204.0 299.6

742.1 270.0 472.1

993.9 408.0 585.9

6 103.1 34.0 69.1

153.7 61.0 92.7

261.3 106.0 155.3

584.2 230.0 354.2

860.9 311.0 549.9

1,153.0 460.0 693.0

7 117.8 31.0 86.8

176.7 51.0

125.7

300.4 88.0

212.4

671.5 165.5 506.0

989.5 261.0 728.5

1,325.3 331.0 994.3

8 132.5 36.0 96.5

197.9 54.0

143.9

336.4 97.0

239.4

752.0 194.5 557.5

1,108.3 302.0 806.3

1,484.3 389.0

1 095.3

9 147.2 40.0

107.2

220.9 68.0

152.9

375.5 107.0 268.5

839.3 216.0 623.3

1,236.9 339.0 897.9

1,656.6 432.0

1 224.6

10 162.0 31.0

131.0

242.1 45.0

197.1

411.5 86.0

325.5

919.9 165.0 754.9

1,355.7 248.0

1 107.7

1,815.6 330.0

1 485.6

11 176.7 34.0

142.7

265.1 49.0

216.1

450.6 96.0

354.6

1,007.2 182.5 824.7

1,484.3 272.0

1 212.3

1,987.9 365.0

1 622.9

12 191.4 37.0

154.4

286.3 54.0

232.3

486.6 106.0 380.6

1,087.8 198.5 889.3

1,603.0 295.0

1 308.0

2,146.9 397.0

1 749.9

13 206.1 30.0

176.1

309.2 62.0

247.2

525.7 89.0

436.7

1,175.1 160.5

1,014.6

1,731.7 243.0

1,488.7

2,319.2 321.0

1,998.2

14 220.9 32.0

188.9

330.4 67.0

263.4

561.7 96.0

465.7

1,255.6 176.0

1,079.6

1,850.4 261.0

1,589.4

2,478.2 352.0

2,126.2

15 235.6 34.0

201.6

353.4 71.0

282.4

600.8 103.0 497.8

1,342.9 182.5

1,160.4

1,979.1 282.0

1,697.1

2,650.5 365.0

2,285.5

16 250.3 36.0

214.3

374.6 76.0

298.6

636.8 111.0 525.8

1,423.5 201.5

1,222.0

2,097.8 301.0

1,796.8

2,809.6 403.0

2,406.6

Inlet [l/min] Purge air [l/min] Outlet [l/min]

Page 34: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

34 | Festo PDAD 1701g English

PDAD-09 PDAD-13 PDAD-22 PDAD-51 PDAD-73 PDAD-100

Operating pressure p [bar]

Nominal flow rate for –70 °C pressure dew point (inlet temperature 25 °C saturated)

4 51.5 33.0 18.5

5 61.8 30.0 31.8

6 72.1 34.0 38.1

7 82.5 31.0 51.5

8 92.8 36.0 56.8

9 103.1 40.0 63.1

10 113.4 31.0 82.4

11 123.7 34.0 89.7

12 134.0 37.0 97.0

13 144.3 30.0

114.3

14 154.6 32.0

122.6

15 164.9 34.0

130.9

16 175.2 36.0

139.2

77.3 42.0 35.3

92.8 52.0 40.8

108.2 61.0 47.2

123.7 51.0 72.7

139.2 54.0 85.2

154.6 68.0 86.6

170.1 45.0

125.1

185.5 49.0

136.5

201.0 54.0

147.0

216.5 62.0

154.5

231.9 67.0

164.9

247.4 71.0

176.4

262.8 76.0

186.8

131.4 76.0 55.4

157.7 89.0 68.7

184.0 106.0 78.0

210.3 88.0

122.3

236.6 97.0

139.6

262.8 107.0 155.8

289.1 86.0

203.1

315.4 96.0

219.4

341.7 106.0 235.7

368.0 89.0

279.0

394.3 96.0

298.3

420.6 103.0 317.6

446.8 111.0 335.8

293.8 166.0 127.8

352.5 204.0 148.5

411.3 230.0 181.3

470.0 165.5 304.5

528.8 194.5 334.3

587.5 216.0 371.5

646.3 165.0 481.3

705.0 182.5 522.5

763.8 198.5 565.3

822.5 160.5 662.0

881.3 176.0 705.3

940.1 182.5 757.6

998.8 201.5 797.3

432.9 233.0 199.9

519.5 270.0 249.5

606.1 311.0 295.1

692.7 261.0 431.7

779.3 302.0 477.3

865.8 339.0 526.8

952.4 248.0 704.4

1,039.0 272.0 767.0

1,125.6 295.0 830.6

1,212.2 243.0 969.2

1,298.8 261.0

1,037.8

1,385.3 282.0

1,103.3

1,471.9 301.0

1,170.9

579.8 332.0 247.8

695.8 408.0 287.8

811.7 460.0 351.7

927.7 331.0 596.7

1,043.6 389.0 654.6

1,159.6 432.0 727.6

1,275.6 330.0 945.6

1,391.5 65.0

1,026.5

1,507.5 397.0

1,110.5

1,623.4 321.0

1,302.4

1,739.4 352.0

1,387.4

1,855.4 365.0

1,490.4

1,971.3 403.0

1,568.3

Inlet [l/min] Purge air [l/min] Outlet [l/min]

Page 35: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

Festo PDAD 1701g English | 35

77 8 12 17 24 17 (2x)

78 8 12 17 24 17 (2x)

79 8 12 17 24 17 (2x)

94 10 14 23 29 23 (2x)

PDAD-09 PDAD-13 PDAD-22 PDAD-51 PDAD-73 PDAD-100

95 10 14 23 29 23 (2x)

96 10 14 23 29 23 (2x)

610 7 10 14 17 14 (2x)

611 7 10 14 17 14 (2x)

612 7 10 14 17 14 (2x)

513 6 9 12 15 12 (2x)

514 6 9 12 15 12 (2x)

515 6 9 12 15 12 (2x)

516 6 9 12 15 12 (2x)

Operating pressure p [bar]

Number of the air nozzle

Allocating the air nozzles for various operating pressures

For correct and effective operation, there must be a certain amount of purge air, dependent on the operating pressure. By selecting the correct air nozzle, the amount of purge air is adjusted for the operating pressure. An incorrectly selected air nozzle can lead to premature failure of the dryer. The following table shows the allocation of the air nozzles for the various operating pressures. The grey area marks the permitted operating pressure range for the air nozzles included in the scope of delivery. If the operating pressure is outside the marked area, an air nozzle from the air nozzle set is required, see chapter 10

Page 36: Adsorption dryer PDAD · filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow).

The reproduction, distribution and utilisation of this document as well as the communication of its contents to others without express authorisation is prohibited. Offenders will be held liable for the payment of damages.. All rights reserved in the event that a patent, utility model or design patent is registered.

Copyright:© Festo AG & Co. KG,PO boxD-73726 Esslingen, Germany

Phone:+49 711 347-0

Fax:+49 711 347-2144

e-mail:[email protected]

Internet:http://www.festo.com

Original: deVersion: 1701g


Recommended