Div. of TMP Technologies Inc.Advanced Rubber Products
ADVANCED RUBBER PRODUCTS
Silicone Polymer Horizontal & Vertical Line Post Insulators
15KV, 25KV, 35KV, 46KV, & 69KV
6110 Lamb Road • Wyoming, NY 14591 www.arp-hivoltageinsulators.comPhone: 585.495.6231 • Fax: 585.495.6526 email: info.arp-hivoltageinsulators.com
Cat
alog
Num
ber
Volta
ge
Cla
ss
Gai
nBa
se T
oHo
rizon
tal
Fitti
ngCe
nter
Lin
e
Bas
e To
H
oriz
onta
l Fi
tting
Cen
ter
Line
Shed
Dim
ensi
ons
Fibe
rgla
ss
Rod
D
iam
eter
Num
ber
of
Shed
s
Leak
age
Dis
tanc
e In
ch/
mm
Dry
Arc
D
ista
nce
Inch
/mm
Spec
ified
Cant
ileve
rLo
ad
Max
Desi
gnCa
ntile
ver
Load
Tens
ile
Stre
ngth
Low
Fre
quen
cy
Flas
hove
rIm
puls
e Fl
asho
ver
RIV
Pack
agin
g In
fo
MIN
OR
DIA
MA
JOR
DIA
DRY
WET
POS
NEG
60H
z Te
stM
AX
RIV
@
1MH
zN
et W
eigh
t Ea
chN
o. In
St
d. B
ox
AR
P-L
PH
-15S
K15
kV11
.44”
10.0
4”/2
55m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”4
12.6
8”/3
22m
m7.
72”/1
96m
m28
10lb
s13
48lb
s49
45lb
s86
kV66
kV14
6kV
193k
V10
kV10
0uV
7.5
lbs.
6
AR
P-L
PH
-25S
K25
kV15
.93”
14.5
3”/3
69m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”6
20.3
1”/5
16m
m12
.28”
/312
mm
2810
lbs
1348
lbs
4945
lbs
122k
V10
3kV
208k
V27
1kV
15kV
100u
V8.
0 lb
s.6
AR
P-L
PH
-35S
K35
kV18
.21”
16.8
1”/4
27m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”7
24.1
3”/6
13m
m14
.57”
/370
mm
2810
lbs
1348
lbs
4945
lbs
141k
V12
2kV
239k
V30
9kV
22kV
100u
V9.
5 lb
s.6
AR
P-L
PH
-35S
KH
P35
kV22
.01”
20.6
1”/5
23.5
mm
n/a
6.69
”/170
mm
1.77
”5
33.8
6”/8
60m
m14
.13”
/359
mm
5000
lbs
2500
lbs
4945
lbs
138k
V12
3kV
228k
V27
7kV
22kV
100u
V10
.9 lb
s.1
AR
P-L
PH
-46S
K46
kV27
.01”
25.6
1”/6
50.5
mm
n/a
6.69
”/170
mm
1.77
”7
47.0
5”/1
195m
m19
.17”
/487
mm
2450
lbs
1225
lbs
4945
lbs
188k
V16
8kV
310k
V37
6kV
44kV
200u
V16
.0 lb
s.1
AR
P-L
PH
-69S
K69
kV29
.51”
28.1
1”/7
14m
mn/
a6.
69”/1
70m
m1.
77”
854
.61”
/138
7mm
21.6
5”/5
50m
m24
50lb
s12
25lb
s49
45lb
s23
0kV
200k
V38
0kV
470k
V44
kV20
0uV
17.6
lbs.
1
AR
P-L
PH
-69S
K-H
P69
kV29
.51”
28.1
1”/7
14m
mn/
a6.
69”/1
70m
m1.
77”
1591
.73”
/233
0mm
22.0
5”/1
560m
m28
00lb
s12
25lb
s49
45lb
s23
0kV
200k
V38
0kV
470k
V44
kV20
0uV
22 lb
s.1
Gai
n-ba
se A
RP
-GB
HA
llH
oriz
onta
l Gai
n-B
ase
9.0
lbs.
AR
P-L
PE
-35S
K35
kV20
.91”
19.7
2”/5
01m
mn/
a6.
69”/1
70m
m1.
77”
533
.86”
/860
mm
14.1
3”/3
59m
m24
50lb
s12
25lb
s49
45lb
s13
8kV
123k
V22
8kV
277k
V22
kV10
0uV
-6
AR
P-L
PE
-46S
K46
kV26
.12”
24.7
2”/6
28m
mn/
a6.
69”/1
70m
m1.
77”
747
.05”
/119
5mm
19.1
7”/4
87m
m24
50lb
s12
25lb
s49
45lb
s18
8kV
168k
V31
0kV
376k
V44
kV20
0uV
-1
AR
P-L
PE
-69S
K69
kV28
.62”
27.2
2”/6
91.5
mm
n/a
6.69
”/170
mm
1.77
”8
54.6
1”/1
387m
m21
.65”
/550
mm
2450
lbs
1225
lbs
4945
lbs
210k
V19
0kV
350k
V42
5kV
44kV
200u
V-
1
Cat
alog
Num
ber
Volta
ge
Cla
ss
Bas
e To
H
oriz
onta
l Fi
tting
Cen
ter
Line
Shed
Dim
ensi
ons
Fibe
rgla
ss
Rod
D
iam
eter
Num
ber
of
Shed
s
Leak
age
Dis
tanc
e In
ch/
mm
Dry
Arc
D
ista
nce
Inch
/mm
Spec
ified
Cant
ileve
rLo
ad
Max
Desi
gnCa
ntile
ver
Load
Tens
ile
Stre
ngth
Low
Fre
quen
cyFl
asho
ver
Impu
lse
Flas
hove
rR
IVPa
ckag
ing
Info
MIN
OR
DIA
MA
JOR
DIA
DRY
WET
POS
NEG
60H
z Te
stM
AX
RIV
@
1MH
zN
et W
eigh
t Ea
chN
o. In
St
d. B
ox
AR
P-L
PV-
15S
K15
kV10
.2”/2
59m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”4
12.6
8”/3
22m
m7.
72”/1
96m
m28
10lb
s13
48lb
s49
45lb
s86
kV66
kV14
6kV
193k
V10
kV10
0uV
8.5
lbs.
6
AR
P-L
PV-
25S
K25
kV14
.69”
/373
mm
3.54
”/90m
m4.
53”/1
15m
m1.
57”
620
.31”
/516
mm
12.2
8”/3
12m
m28
10lb
s13
48lb
s49
45lb
s12
2kV
103k
V20
8kV
271k
V15
kV10
0uV
9.0
lbs.
6
AR
P-L
PV-
35S
K35
kV16
.97”
/431
mm
3.54
”/90m
m4.
53”/1
15m
m1.
57”
724
.13”
/613
mm
14.5
7”/3
70m
m28
10lb
s13
48lb
s49
45lb
s14
1kV
122k
V23
9kV
309k
V22
kV10
0uV
9.5
lbs.
6
AR
P-L
PV-
46S
K46
kV25
.57”
/649
.5m
mn/
a6.
69”/1
70m
m1.
77”
747
.05”
/119
5mm
19.1
7”/4
87m
m24
50lb
s12
25lb
s49
45lb
s18
8kV
168k
V31
0kV
376k
V44
kV20
0uV
16.0
lbs.
1
AR
P-L
PV-
69S
K69
kV28
.07”
/713
mm
n/a
6.69
”/170
mm
1.77
”8
54.6
1”/1
387m
m21
.65”
/550
mm
2450
lbs
1225
lbs
4945
lbs
230k
V20
0kV
380k
V47
0kV
44kV
200u
V17
.8 lb
s.1
AR
P-L
PV-
69S
K-H
P69
kV28
.07”
/713
mm
5.91
”/150
mm
6.69
”/170
mm
1.77
”15
91.7
3”/2
330m
m22
.05”
/156
0mm
2800
lbs
1225
lbs
4945
lbs
230k
V20
0kV
380k
V47
0kV
44kV
200u
V22
lbs.
1
Gai
n-ba
se A
RP
-GB
VA
llVe
rtica
l Gai
n-B
ase
10.0
lbs
Camden Printing Form 14325 - Rev. 2-15 (23679)
NO
TE:
1.E
nd F
ittin
gs a
re m
ade
from
Sph
eroi
dal G
raph
ite C
ast I
ron.
2.Fi
berg
lass
sol
id c
ore
rod
is m
ade
usin
g E
poxy
Res
in.
3.C
lam
p an
d S
tud
Bas
e di
men
sion
s ar
e in
acc
orda
nce
with
AN
SI C
29.7
.4.
Bas
e an
d In
sula
tor a
re jo
ined
with
a 3
/4” B
olt &
Loc
k W
ashe
r.5.
15, 2
5, &
35K
V In
sula
tors
- 3/
4-10
UN
C G
alva
nize
d B
olt s
uppl
ied
with
Gai
n B
ase.
6.46
& 6
9KV
Insu
lato
rs -
7/8-
10 U
NC
Gal
vani
zed
Bol
t sup
plie
d w
ith G
ain
Bas
e.7.
Cat
alog
Num
ber “
HP
” des
igna
tes
Hig
h P
erfo
rman
ce
Cat
alog
Num
berin
g Sy
stem
A R
P
- L
P H
-
1 5
S K
G B
-
1
Line
Pos
t
Volta
ge
Mat
eria
l & F
acto
ry L
ocat
ion
H :
Hor
izon
tal
V :
Verti
cal
E :
Eye
End
GB
V :
Gai
n B
ase
Verti
cal
GB
H :
Gai
n B
ase
Hor
izon
tal
1 : T
SC
-106
™
ARP-LPH-15SKGB
12.0
2.5
49.5
7.0
1.0
Silicone Polymer Horizontal Line Post Insulators Silicone Polymer Vertical Line Post Insulators
ARP-LPV-15SK ARP-LPV-25SK
ARP-LPV-35SK ARP-LPV-69SK
ARP-LPV-46SK
GAIN BASE ARP-GBV
ARP Hor izon ta l Gain Base is inter- changeable with most other industry bases and can be mounted to existing 6" center to center pole mounting holes.
4”
14.3
”
3”
5”
1.1
”
2.9”
4”4”
14.3
”
3”
5”
1.1
”
2.9”
4”4”
14.3
”
3”
5”
1.1
”
2.9”
4”
5.31 in
2.0
in
.56 in
.9 in
3.8
5 in
CABLE CLAMP
ARP-LPH-35SKGB
ARP-LPH-69SKGB
ARP-LPH-25SKGB
GAIN BASE ARP-GBH
ARP-LPH-46SKGBARP-LPH-35SKGBHP
ARP-LPH-69SKGBHP
11.44" 15.93"18.21"
27.01"
29.51" 29.51"
22.01"
PART NUMBERCONDUCTOR RANGE
MIN MAX
ARP-TSC-106 .375” 1.06”
ARP-LPH-15SKGB
12.0
2.5
49.5
7.0
1.0
Silicone Polymer Horizontal Line Post Insulators Silicone Polymer Vertical Line Post Insulators
ARP-LPV-15SK ARP-LPV-25SK
ARP-LPV-35SK ARP-LPV-69SK
ARP-LPV-46SK
GAIN BASE ARP-GBV
ARP Hor izon ta lGain Base is inter-changeable withmost other industrybases and can bemounted to existing6" center to centerpole mounting holes.
4”
14.3
”
3”
5”
1.1
”
2.9”
4”4”
14.3
”
3”
5”
1.1
”
2.9”
4”4”
14.3
”
3”
5”
1.1
”
2.9”
4”
5.31 in
2.0
in
.56 in
.9 in
3.8
5 in
CABLE CLAMP
ARP-LPH-35SKGB
ARP-LPH-69SKGB
ARP-LPH-25SKGB
GAIN BASE ARP-GBH
ARP-LPH-46SKGBARP-LPH-35SKGBHP
ARP-LPH-69SKGBHP
11.44" 15.93"18.21"
27.01"
29.51" 29.51"
22.01"
PART NUMBERCONDUCTOR RANGE
MIN MAX
ARP-ATC-150 .375” 1.06”
Div. of TMP Technologies Inc.Advanced Rubber Products
ADVANCED RUBBER PRODUCTS
Silicone Polymer Horizontal & Vertical Line Post Insulators
15KV, 25KV, 35KV, 46KV, & 69KV
6110 Lamb Road • Wyoming, NY 14591 www.arp-hivoltageinsulators.comPhone: 585.495.6231 • Fax: 585.495.6526 email: info.arp-hivoltageinsulators.com
Cat
alog
Num
ber
Volta
ge
Cla
ss
Gai
n Ba
se T
o Ho
rizon
tal
Fitti
ng
Cent
er L
ine
Bas
e To
H
oriz
onta
l Fi
tting
Cen
ter
Line
Shed
Dim
ensi
ons
Fibe
rgla
ss
Rod
D
iam
eter
Num
ber
of
Shed
s
Leak
age
Dis
tanc
e In
ch/
mm
Dry
Arc
D
ista
nce
Inch
/mm
Spec
ified
Ca
ntile
ver
Load
Max
De
sign
Ca
ntile
ver
Load
Tens
ile
Stre
ngth
Low
Fre
quen
cy
Flas
hove
rIm
puls
e Fl
asho
ver
RIV
Pack
agin
g In
fo
MIN
OR
DIA
MA
JOR
DIA
DRY
WET
POS
NEG
60H
z Te
stM
AX
RIV
@
1MH
zN
et W
eigh
t Ea
chN
o. In
St
d. B
ox
AR
P-L
PH
-15S
K15
kV11
.44”
10.0
4”/2
55m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”4
12.6
8”/3
22m
m7.
72”/1
96m
m28
10lb
s13
48lb
s49
45lb
s86
kV66
kV14
6kV
193k
V10
kV10
0uV
7.5
lbs.
6
AR
P-L
PH
-25S
K25
kV15
.93”
14.5
3”/3
69m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”6
20.3
1”/5
16m
m12
.28”
/312
mm
2810
lbs
1348
lbs
4945
lbs
122k
V10
3kV
208k
V27
1kV
15kV
100u
V8.
0 lb
s.6
AR
P-L
PH
-35S
K35
kV18
.21”
16.8
1”/4
27m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”7
24.1
3”/6
13m
m14
.57”
/370
mm
2810
lbs
1348
lbs
4945
lbs
141k
V12
2kV
239k
V30
9kV
22kV
100u
V9.
5 lb
s.6
AR
P-L
PH
-35S
KH
P35
kV22
.01”
20.6
1”/5
23.5
mm
n/a
6.69
”/170
mm
1.77
”5
33.8
6”/8
60m
m14
.13”
/359
mm
5000
lbs
2500
lbs
4945
lbs
138k
V12
3kV
228k
V27
7kV
22kV
100u
V10
.9 lb
s.1
AR
P-L
PH
-46S
K46
kV27
.01”
25.6
1”/6
50.5
mm
n/a
6.69
”/170
mm
1.77
”7
47.0
5”/1
195m
m19
.17”
/487
mm
2450
lbs
1225
lbs
4945
lbs
188k
V16
8kV
310k
V37
6kV
44kV
200u
V16
.0 lb
s.1
AR
P-L
PH
-69S
K69
kV29
.51”
28.1
1”/7
14m
mn/
a6.
69”/1
70m
m1.
77”
854
.61”
/138
7mm
21.6
5”/5
50m
m24
50lb
s12
25lb
s49
45lb
s23
0kV
200k
V38
0kV
470k
V44
kV20
0uV
17.6
lbs.
1
AR
P-L
PH
-69S
K-H
P69
kV29
.51”
28.1
1”/7
14m
mn/
a6.
69”/1
70m
m1.
77”
1591
.73”
/233
0mm
22.0
5”/1
560m
m28
00lb
s12
25lb
s49
45lb
s23
0kV
200k
V38
0kV
470k
V44
kV20
0uV
22 lb
s.1
Gai
n-ba
se A
RP
-GB
HA
llH
oriz
onta
l Gai
n-B
ase
9.0
lbs.
AR
P-L
PE
-35S
K35
kV20
.91”
19.7
2”/5
01m
mn/
a6.
69”/1
70m
m1.
77”
533
.86”
/860
mm
14.1
3”/3
59m
m24
50lb
s12
25lb
s49
45lb
s13
8kV
123k
V22
8kV
277k
V22
kV10
0uV
-6
AR
P-L
PE
-46S
K46
kV26
.12”
24.7
2”/6
28m
mn/
a6.
69”/1
70m
m1.
77”
747
.05”
/119
5mm
19.1
7”/4
87m
m24
50lb
s12
25lb
s49
45lb
s18
8kV
168k
V31
0kV
376k
V44
kV20
0uV
-1
AR
P-L
PE
-69S
K69
kV28
.62”
27.2
2”/6
91.5
mm
n/a
6.69
”/170
mm
1.77
”8
54.6
1”/1
387m
m21
.65”
/550
mm
2450
lbs
1225
lbs
4945
lbs
210k
V19
0kV
350k
V42
5kV
44kV
200u
V-
1
Cat
alog
Num
ber
Volta
ge
Cla
ss
Bas
e To
H
oriz
onta
l Fi
tting
Cen
ter
Line
Shed
Dim
ensi
ons
Fibe
rgla
ss
Rod
D
iam
eter
Num
ber
of
Shed
s
Leak
age
Dis
tanc
e In
ch/
mm
Dry
Arc
D
ista
nce
Inch
/mm
Spec
ified
Ca
ntile
ver
Load
Max
De
sign
Ca
ntile
ver
Load
Tens
ile
Stre
ngth
Low
Fre
quen
cy
Flas
hove
rIm
puls
e Fl
asho
ver
RIV
Pack
agin
g In
fo
MIN
OR
DIA
MA
JOR
DIA
DRY
WET
POS
NEG
60H
z Te
stM
AX
RIV
@
1MH
zN
et W
eigh
t Ea
chN
o. In
St
d. B
ox
AR
P-L
PV-
15S
K15
kV10
.2”/2
59m
m3.
54”/9
0mm
4.53
”/115
mm
1.57
”4
12.6
8”/3
22m
m7.
72”/1
96m
m28
10lb
s13
48lb
s49
45lb
s86
kV66
kV14
6kV
193k
V10
kV10
0uV
8.5
lbs.
6
AR
P-L
PV-
25S
K25
kV14
.69”
/373
mm
3.54
”/90m
m4.
53”/1
15m
m1.
57”
620
.31”
/516
mm
12.2
8”/3
12m
m28
10lb
s13
48lb
s49
45lb
s12
2kV
103k
V20
8kV
271k
V15
kV10
0uV
9.0
lbs.
6
AR
P-L
PV-
35S
K35
kV16
.97”
/431
mm
3.54
”/90m
m4.
53”/1
15m
m1.
57”
724
.13”
/613
mm
14.5
7”/3
70m
m28
10lb
s13
48lb
s49
45lb
s14
1kV
122k
V23
9kV
309k
V22
kV10
0uV
9.5
lbs.
6
AR
P-L
PV-
46S
K46
kV25
.57”
/649
.5m
mn/
a6.
69”/1
70m
m1.
77”
747
.05”
/119
5mm
19.1
7”/4
87m
m24
50lb
s12
25lb
s49
45lb
s18
8kV
168k
V31
0kV
376k
V44
kV20
0uV
16.0
lbs.
1
AR
P-L
PV-
69S
K69
kV28
.07”
/713
mm
n/a
6.69
”/170
mm
1.77
”8
54.6
1”/1
387m
m21
.65”
/550
mm
2450
lbs
1225
lbs
4945
lbs
230k
V20
0kV
380k
V47
0kV
44kV
200u
V17
.8 lb
s.1
AR
P-L
PV-
69S
K-H
P69
kV28
.07”
/713
mm
5.91
”/150
mm
6.69
”/170
mm
1.77
”15
91.7
3”/2
330m
m22
.05”
/156
0mm
2800
lbs
1225
lbs
4945
lbs
230k
V20
0kV
380k
V47
0kV
44kV
200u
V22
lbs.
1
Gai
n-ba
se A
RP
-GB
VA
llVe
rtica
l Gai
n-B
ase
10.0
lbs
Camden Printing Form 14325 - Rev. 8-15 (23679)
NO
TE:
1.E
nd F
ittin
gs a
re m
ade
from
Sph
eroi
dal G
raph
ite C
ast I
ron.
2.Fi
berg
lass
sol
id c
ore
rod
is m
ade
usin
g E
poxy
Res
in.
3.C
lam
p an
d S
tud
Bas
e di
men
sion
s ar
e in
acc
orda
nce
with
AN
SI C
29.7
.4.
Bas
e an
d In
sula
tor a
re jo
ined
with
a 3
/4” B
olt &
Loc
k W
ashe
r.5.
15, 2
5, &
35K
V In
sula
tors
- 3/
4-10
UN
C G
alva
nize
d B
olt s
uppl
ied
with
Gai
n B
ase.
6.46
& 6
9KV
Insu
lato
rs -
7/8-
10 U
NC
Gal
vani
zed
Bol
t sup
plie
d w
ith G
ain
Bas
e.7.
Cat
alog
Num
ber “
HP
” des
igna
tes
Hig
h P
erfo
rman
ce
Cat
alog
Num
berin
g Sy
stem
A R
P
- L
P H
-
1 5
S K
G B
-
1
Line
Pos
t
Volta
ge
Mat
eria
l & F
acto
ry L
ocat
ion
H :
Hor
izon
tal
V :
Verti
cal
E :
Eye
End
GB
V :
Gai
n B
ase
Verti
cal
GB
H :
Gai
n B
ase
Hor
izon
tal
1 : T
SC
-106