Intrusion Alarm Systems | AMAX panel 3000 AMAX panel 3000 www.boschsecurity.com u 32 Hardwired zones / 8 Areas / 64 User codes u 3 x 256 Events log stamped with date and time u On-board voice dialer u Macro functionality u USB direct connection The intrusion alarm system AMAX panel 3000 is designed for residential and small to medium-sized businesses. It offers 32 zones and 8 areas and comes with an enclosure and a transformer. An on-board PSTN dialer transmits an alarm via the common telephone network to a phone and/or a communication center while at the same time a voice message is sent to the owner’s landline or mobile phone to inform him about an intruder’s presence. Commissioning the system is simple and involves minimum programming: the default settings already cover 90 % of the available functionality. Programming can either be done via the AMAX TEXT, LCD and LED keypads or via the programming software (A-Link Plus). The intrusion system can be used with both RADION wireless peripherals, operating at 433 Mhz and hardwired detectors from Bosch. System overview Phone Option Bus AMAX panel 3000 CMS Programming SW A-Link Plus PSTN Telephone Network
Transcript
  • Intrusion Alarm Systems | AMAX panel 3000

    AMAX panel 3000

    www.boschsecurity.com

    u 32 Hardwired zones / 8 Areas / 64 User codes

    u 3 x 256 Events log stamped with date and time

    u On-board voice dialer

    u Macro functionality

    u USB direct connection

    The intrusion alarm system AMAX panel 3000 isdesigned for residential and small to medium-sizedbusinesses. It offers 32 zones and 8 areas and comeswith an enclosure and a transformer. An on-boardPSTN dialer transmits an alarm via the commontelephone network to a phone and/or acommunication center while at the same time a voicemessage is sent to the owner’s landline or mobilephone to inform him about an intruder’s presence.Commissioning the system is simple and involvesminimum programming: the default settings alreadycover 90 % of the available functionality. Programmingcan either be done via the AMAX TEXT, LCD and LEDkeypads or via the programming software (A-LinkPlus).The intrusion system can be used with both RADIONwireless peripherals, operating at 433 Mhz andhardwired detectors from Bosch.

    System overview

    Phone

    Option Bus

    AMAX panel 3000

    CMS Programming SW

    A-Link Plus

    P S T NTelephone

    Network

  • Functions

    AMAX panel 3000 is a 32 zone / 8 area intrusioncontrol panel with enclosure and transformer. Thesystem includes a PSTN dialer to transmit an alarm viathe common telephone network. An alarm can betransmitted to a phone and a communication center.Program the control panel easily with the AMAX TEXT,LCD and LED keypads or via the remote programmingsoftware, A-Link Plus.

    Basic functions• Keypad Code STAY / AWAY Arming• One Button STAY / AWAY Arming• On-board dialer with CID / SIA transmission format.

    Voice dialer transmits up to 4 recorded messages tolandline/mobile phones in case of an alarm. Recordmessages with a PC and send to the control panelwith the remote programming software, A-Link Plus.

    • Program up to 16 weekly schedules and exceptions inthe calendar.

    • 3 programmable macros: several single functionsfrom the keypad are combined to one customermacro function. Execute by pressing one button.

    • Program the control panel with the new release ofremote programming software, A-Link Plus. All controlpanel and status information are accessible.

    • Execute remote maintenance operations (eg. WalkTest, Bypass)

    • In multi-area set-up (direct and multiple arming),“area status” is displayed.

    • Display Area Name in the master keypad• 3 on-board outputs (two monitored)• Use any zone with four-wire fire detectors• Use any zone for Chime Mode (Door Bell)• Use any zone to detect Sensor Tamper (DEOL)• Test Mode for outputs and zones

    Optional functions• Wireless devices (433 MHz) RADION from Bosch• Zone inputs on extension modules (with DX2010)• Relay outputs on extension modules (with DX3010)• Connect outdoor sirens and IP cameras to an optional

    8 relay module (DX3010)• Programming key

    Optional Alarm Transmission• IP communication with Bosch Conettix IP / SIA DC09

    (UDP) Protocol via B426 module• GPRS communication with Bosch Conettix IP l / SIA

    DC09 (UDP) Protocol via B450 module

    Optional Remote Programming• IP (B426 module)• GPRS (B450 module)

    Optional Video Alarm VerificationOptional video alarm verification is possible incombination with DX3010 8 relay module and IP 200camera series of Bosch. The live video verificationensures a location check and false alarm reduction viaInternet from every location worldwide. This meansthat you or the monitoring center can get alarm

    notification in order to detect the exact location wherethe alarm was triggered and if a real intruder ispresent.

    Compatibility Information

    Basic

    PSTN Communicator (Integrated) Formats:Contact ID, SIA

    Magnetic Contacts (1) All magnetic contacts, includingrecessed, terminal connection,miniature over-head door, andsurface mount.

    Intrusion Detectors (1) All conventional intrusiondetectors, including Blue Line,seismic, PIR, TriTech,photoelectric and TriTech PIRMicrowave.

    Four-wire Smoke Detectors (1, 2) Conventional 12V smoke, heatand photoelectric smokedetectors.

    Optional (1, 2)

    Zone DX2010 zone input module

    Relays DX3010 output module

    IP-Communicator B426 Ethernet Network InterfaceModule

    GPRS/GSM Communicator B450 Module

    Assorted literature is available. Refer to theappropriate datasheet, brochure, and installationguide for additional data.Availability varies according to sales region.

    Certifications and approvals

    Region Certification

    Europe EN50131

    EN-ST-000166 AMAX panel 2100/3000

    Parts included

    CTN Pcs Description

    AMAX panel 3000 1 32 zone / 8 areas intrusion panelwith enclosure and transformer,tamper, integrated PSTN-Comm-unicator

    1 User Guide, multilingual

    Technical specifications

    Panel

    Enclosure:

    Dimensions (HxWxD): • 260 x 280 x 83,5 mm(L x W x H)

    Weight: • 1950g

    2 | AMAX panel 3000

  • Environmental Considerations:

    Relative Humidity: • 10%-95%

    OperatingTemperature:

    • -10°C - +55°C

    Supervised Zones:

    Onboard:

    Z1 – Z8 COM: • 8 Single or dual end-of-line (EOL2,2KΩ) tamper point support

    Tamper: • Enclosure tamper input (does notreduce point capacity)

    Programmable Outputs (PO):

    Onboard:

    PO -1: • supervised output max 500mA

    PO -2: • supervised output max 500mA

    Relay: • -12V output max 100mA

    Number of...

    Zones: • 32

    Users: • 128

    Key Fobs: • 128

    Events: • 256 history events, stamped withtime and date

    • 256 EN history events, stamped withtime and date

    • 256 dialer history events, stampedwith time and date

    Pin Code variations: • 1.000.000

    Keypads: • 8

    DX 2010 • 3

    DX 3010: • 2

    B426: • 2

    B450: • 1

    Wireless Receiver: • 1

    Wireless Devices: • 32

    Power:

    Power Supply Type: • A

    Transformer: • 230V Input/18VAC 20VAFuse=500mA

    AC Input: • AC Input Voltage: 195 VAC to 253VAC

    • Line Voltage Frequency: 50 Hz• Panel AC Input Voltage: 18-22V AC

    DC Output: • maximum current for all components1100mA

    • max current for all componentsBattery 7Ah standby 12h (rechargeBatt 80% in 72h) = 550mA

    Aux (+12V/GND)Output:

    • 500mA maximum

    Option Bus : • 500mA maximum

    Cable requirements: • four wire, AWG18 or AWG22• maximum length 200m (Panel to last

    KP)• maximum BUS 1 length 700m ( max

    14 devices, max 8 KPs)

    Panel PCB: • Quiescent current maximum 100mA

    Battery: • 12V/7 Ah, lead acid rechargeable

    Ordering information

    AMAX panel 3000Language Package 1: English, Polish, TurkishOrder number ICP-AMAX3-P1

    AMAX keypad 2000 D8AMAX keypad 2000 D8, 8 zones LCD Icon keypad.Order number IUI-AMAX-LCD8

    Accessories

    AMAX keypad 2000 L8AMAX keypad 2000 L8, 8 zone LED keypad.Order number IUI-AMAX-LED8

    AMAX keypad 3000 L8AMAX keypad 3000 L8 is a 8 zone LED keypad.Approval: EN 50131-3 Grade 2Order number IUI-AMAX3-LED8

    AMAX keypad 3000 L16AMAX keypad 3000 L16 is a 16 zone LED keypad.Approval: EN 50131-3 Grade 2Order number IUI-AMAX3-LED16

    AMAX keypad 4000 TAMAX keypad 4000 T, LCD text keypad, two lines witheach 18 characters.Order number IUI-AMAX4-TEXT

    ICP-EZPKProgramming KeyOrder number ICP-EZPK

    AE20ENAE20EN plastic enclosure for DX2010/DX3010.Order number AE20EN

    DX2010 Input ExpanderZone expansion module with 8 DOEL zone inputs.Order number DX2010

    DX3010 Octo‑output ExpanderPackage includes only the DX3010 board.Order number DX3010

    3 | AMAX panel 3000

  • B426 Ethernet Communication ModuleSupports two-way communications over Ethernetnetworks for compatible control panels.Order number B426

    B442 Conettix Plug-in GPRS Cellular CommunicatorMulti-function cellular communicator that provides IPcommunication over a (GPRS) cellular network.Order number B442

    B443 Conettix Plug-in HSPA+ Cellular CommunicatorMulti-function 3G/4G cellular communicator providingIP communication over a GPRS/EDGE/UMTS/HSPA+cellular network.Order number B443

    B450 Conettix Plug-in Communicator InterfaceSupports two-way IP communication over commercialcellular networks using a plug-in CellularCommunicator for compatible control panels.Order number B450

    4 | AMAX panel 3000

    Represented by:

    Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

    Bosch Security Systems B.V.P.O. Box 800025617 BA Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

    Robert Bosch (SEA) Pte Ltd, SecuritySystems11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 [email protected]

    Bosch (Shanghai) Security Systems Ltd.201 Building, No. 333 Fuquan RoadNorth IBPChangning District, Shanghai200335 ChinaPhone +86 21 22181111Fax: +86 21 22182398www.boschsecurity.com.cn

    Robert Bosch Ltda Security Systems DivisionVia Anhanguera, Km 98CEP 13065-900Campinas, Sao Paulo, BrazilPhone: +55 19 2103 2860Fax: +55 19 2103 [email protected]

    © Bosch Security Systems 2014 | Data subject to change without notice13940070283 | en, V6, 09. Dec 2014


Recommended