2
12'-0" 4'-0" TYP. SOUTH UNISTRUT P1000T 2x2x3/16 L 2x2x3/16 L UNISTRUT P1000T BURIED STEEL 'L' ANCHORS 2x2x3/16 L 2x2x3/16 L KD205GX-LP 6 EA. KYOCERA PV MODULES UNISTRUT P1000T UNDER PANELS UNDER PANELS 59.1 49.1 A A SET IN CONCRETE UNISTRUT P1000T DETAIL ANCHOR 8" 3" 1'-0" 11 1 2 " TYPICAL SEE DETAIL 28° 4'-0" TYP. BURIAL DEPTH 80% + WET/COMPACT SOIL CONCRETE @ HOLE BOTTOM, 3" STEEL COVER PV MODULES 2x2x3/16 L SOUTH 4'-0" C-C TYP. 11'-4" C-C TYP. UNISTRUT P1000T HDG METAL 2"x2"x3/16" HDG STEEL BOLTS 1/2"x1" HDG TOUCH UP ALL CUTS/DRILL HOLES w/ RUSTOLEUM HARDHAT COLD GALV. NOTES: 90° 5 ' - 3 3 4 " 6'-4 7 8 " 6'-4 7 8 " 4'-0" + - GND 600 VDC rated Fused Disc. 15A Sunny Boy 4000 Inv. 30 Amp Nema 3 Disc. 30 N Gnd N Gnd + - + - + - + - - + - + - GND GND GND GND GND GND + - + - + - - + + - + - GND GND GND GND GND GND #1 #2 #3 #4 #5 #6 Mod Mod Mod Mod Mod Mod #7 #8 #9 #10 #11 #12 Mod Mod Mod Mod Mod Mod Existing Utility Meter Inside Bldg Outside Bldg Existing House Panel 2 #10 eg in 1" Sch 40 PVC Fused 3 #10 THWN & #10 eg in 3 #10 THWN & #10 eg in 150 Amp MCB NOTES: 2 #10 USE-2 & #10 eg in 3. 30 Amp circuitbreaker to be located in House Panel, as required by NEC 690.64(B)(7). 1. 30 Amp Disc shall be loacated adjacent to utility service entrance. 2. All signage shall be provided as required by the NEC. Gnd Rod 45' 8' 2 #10 OEM Type TC K2 90 C, 600v w/2 spare & 3/4" Sch 40 PVC 3/4" Sch 40 PVC 3/4" Sch 40 PVC # 6 GEC Nema 3 J-Box 4. All electrical connections are to be made in compliance with manufacturer's specifications and NEC ed. 2008. #10 eg (typ) OEM MC type 4m cable, #10 USE-2 (typ) http://www.kyocerasolar.com/pdf/specsheets/kd_205gx-lp_081508_web.pdf OWNER: WIND LOAD: DESIGNED FOR 110 MPH LEGAL DESCRIPTION: FOREST HILLS UNREC A TRACT IN NE1/4 OF NE1/4 OF 33-21-20 AKA N1/2 OF TRACT 199 WIND EXPOSURE: EXPOSURE CATEGORY B SHEET NO: DATE SAVED: PUBLISHED: SHEET NAME: ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com DRAWN: 06 SCALE: N.T.S. CONSTRUCTION DETAILS SCALE: 1/4" = 1'-0" ISOMETRIC PARTIAL EXPLODED ASSEMBLY SCALE: 1/4" = 1'-0" SECTION A APPLICABLE CODE: FLORIDA BUILDING CODE 2007 FLORIDA ELEC. 2007 CODE W/09 SUPP REVISIONS: THIS SHEET 1 OF 2 DESIGNED PER: ASCE 7-05 CHECKED: SB/JT AG 0025_Brooksville-Blackjack.dwg COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE William Daughrity 26330 Blackjack St Brooksville, FL 34601 (352) 799-5117. 8/30/2009 9:42 PM 8/30/2009 9:42:34 PM 26330 Blackjack St. Brooksville, FL 34601 NEC 2008 05 SCALE: N.T.S. PV WIRING / SCHEMATIC 02 SCALE: N.T.S. PROPERTY LOCATION 03 SCALE: N.T.S. INSTALLATION LOCATION 01 SCALE: N.T.S. INSTALLATION NOTES I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE AND NATIONAL ELECTRICAL CODE. RATED VALUES FOR SOLAR WORLD, SW-175 PV MODULES * *QUANTITIES MEASURED @ 25 DEGREES CELSIUS PMAX=175 W VSC=44.4 V VMP=35.8 V ISC=5.30 A IMP=4.89 A MINIMUM AC & DC WIRING SIZE #10 AWG COPPER (OEM WIRING & HARNESS EXCLUDED) SMA SUNNY BOY 4000 GRID TIED INVERTER Photo-Voltaic Solar Energy System Installation Notes: This plan gives site-specific installation details for a photovoltaic (solar electric) system to be installed at the above location. The solar modules shall be 12-each Koycera model KD205GX-LP wired in series. This shall be a grid-tied system using an SMA SunnyBoy model 4000 inverter. Manufacturer information may be viewed at the following links: http://www.kyocerasolar.com/pdf/specsheets/kd_205gx-lp_081508_web.pdf http://www.sma-america.com/en_US/products/grid-tied-inverters/sunny-boy/sunny-boy-3000us-4000us.html Wiring shall be as shown in Figure 03. All Contractor AC & DC wiring shall use 10 AWG copper (minimum). OEM wiring and harnesses, regardless of wire size, are acceptable when applied to the OEM use intended such as PV-module to PV-module connections. My wind calculations may be viewed at the following hyperlink: http://www.gezelmanpe.com/Installationdwgs.html This plan may be viewed at a magnification of your choice at that site. Special considerations: The PV modules will be installed as a ground-mount on the rack shown on this plan sheet. PV-modules produce electricity when exposed to sunlight. Keep covered with opaque material until all wiring is completed. Twisted (wire nut) connections are not permitted for DC wiring. Use OEM plug connector harness between PV modules. Terminate in watertight junction or combiner boxes with screw terminals/busses at the electrical output end of the PV module strings -multiple strings terminate in one box. Make solid mechanical connections to ensure electrical conductivity between all PV module enclosures and framing members with no electrically isolated components, use #10 AWG bare copper with screwed connections for bonding jumpers as needed. Do not leave loose unsecured wires/harness between PV-modules, tie to the mounting rails or frame with UV resistant zip ties or approved wire clips in neat, professional manner. Use approved means and methods per 2008 NEC 04 SCALE: N.T.S. SYSTEM CALCULATIONS & MANUFACTUER SPECS SCALE: 1/4" = 1'-0" FOUNDATION PLAN SCALE: 1/4" = 1'-0" PARTIAL FRAME PLAN ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/ 0025_Brooksville-Blackjack.dwg ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/ 0025_Brooksville-Blackjack.dwg THIS PLAN AND ITS USE ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENTS COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) . EJCDC C-700 MAY BE REVIEWED AT THE FOLLOWING HYPERLINK: HTTP://WWW.DOUGLASAZ.GOV/PUBLICWORKS/DOCUMENTS/RFP/SEWER_REHAB_PHASE_I/00700%20-%20EJCDC.PDF PV MODULE: HTTP://WWW.KYOCERASOLAR.COM/PDF/SPECSHEETS/KD_205GX-LP_081508_WEB.PDF INVERTER:HTTP://WWW.SMA-AMERICA.COM/EN_US/PRODUCTS/GRID-TIED-INVERTERS/SUNNY-BOY/SUNNY-BOY-3000US-4000US.HTML UNISTRUT: HTTP://WWW.UNISTRUT.COM/LITERATURE/INDEX.PHP?DOC=NO14&PG=1 UNIRAC (SOLARMOUNT MID CLAMP DETAILS ON PAGE 20): HTTP://WWW.UNIRAC.COM/PDF/II227.PDF IN EVENT OF CONFLICT BETWEEN THIS PLAN AND OEM INSTRUCTIONS, OEM SHALL PREVAIL. PV MODULES ANCHORED TO UNISTRUT P1000T CHANNEL USING UNIRAC SOLARMOUNT MID CLAMP SHOWN IN PHOTO THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL. THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS. EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN. 2.5 KW PV SYSTEM NOTES & CALCULATIONS MODULES: KYOCERA KD205GX-LP, 205 WATTS X12 MODULES MODULE PERFORMANCE CHARACTERISTICS: PEAK POWER WP = 205 WATTS MAX. VOLTAGE VMP = 26.6 VOLTS MAX. CURRENT IMP = 7.71 AMPS VOC = 33.2 VOLTS ISC = 8.36 AMPS MAX SERIES FUSE = 15 AMPS ** ALL MEASUREMENTS ARE AT STANDARD TEST CONDITIONS OF 1000 WATTS/M2 IRRADIANCE AT 25 DEGREES C ** INVERTERS: SONNY BOY 4000 MAX INPUT VOLTAGE = 600 VOLTS DC MIN. VOLTAGE = 285 VOLTS STRING INFORMATION: 1 STRINGS TOTAL; 12 MODULES CONNECTED IN SERIES, VOC = 12 MODULES IN SERIES AT 33.2 VOC = 12 X 33.2V = 398.4 VOLTS VMP = 12 MODULES IN SERIES AT 26.6 VMP = 12 X 26.6V = 319.2 VOLTS ISC = 8.36 AMPS IMP = 7.71 AMPS POWER = 12 MODULES AT 205 WATTS = 12 X 205 W= 2460 WATTS TEMPERATURE CORRECTION FOR CRYSTALLINE MODULES: LOWEST RECORDED TEMPERATURE FOR FLORIDA IS -4 TO -4 DEG.F. PER NEC 2008-T690.7 MAX SYSTEM VOLTAGE CORRECTION FACTOR OF 1.18 12 PANELS IN SERIES X 33.2 VOC = 398.4V X 1.18= 470.1V 470.1 < 600 VOLTS MAXIMUM ALLOWED. PASSED MAXIMUM CURRENT: OVER IRRADIATION: EACH STRING HAS AN ISC OF 8.36 AMPS 125% CORRECTION PER NEC 690.8(A)(1)= 8.36 AMPS X 1.25=10.45 AMPS CONTINUOUS CURRENT: 125% CORRECTION PER NEC 690.8(B)(1) =10.45 AMPS X 1.25 = 13.1 AMPS VOLTAGE DROP: FROM 12 MODULE STRING TO INVERTER: % VD = 2 (70FT) 1.29OHMS (13.1 AMPS) 100% / ((1000FT) 319.2V) %VD = 0.74% CONDUCTOR AMPACITY #10 THWN: NEC TABLE 310.16 W/CORRECTION FACTOR @ 40 DEG. C 40 AMPS X .88 = 35.2 AMPS NEC TABLE 310.16 W/CORRECTION FACTOR @ 40 DEG. C AND TABLE 310.15(B) (2) (A) 4 COND. (IF FUTURE USE OF SPARES) 35.2 AMPS X .8 = 28.16 AMPS 01 APPLICATION # 1236137 PLAN EXAMINER COMMENTS 01 01 01 FLORIDA SOLAR ENERGY CENTER CERTIFICATION NUMBER KC09-NT90-0239 I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE THE BELOW ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL: kyocerasolar.com FSEC CERTIFIED :KC09-NT90-0239 01 01 01 01 08.29.09 ELECTRICAL ENGINEER: BRUCE A. TOZIER, P.E. FMR. SGT. USMC TOZIER ENGINEERING, INC. 209 S. GLEN ARVEN AVE. TEMPLE TERRACE, FL 33617 OFF. (813) 988-3578 CELL (813) 951-4727 FAX (813) 988-3578 ! NO COMBINER BOX NEEDED, ONE STRING DESIGN ! 01 01 01 01 01 01
Transcript

12'-0"

4'-0"

TYP.

SOUTH

UNISTRUTP1000T

2x2x3/16 L

2x2x3/16 L

UNISTRUTP1000T

BURIED STEEL 'L' ANCHORS

2x2x3/16 L

2x2x3/16 L

KD205GX-LP6 EA. KYOCERA

PV MODULES

UNISTRUTP1000T

UNDER PANELS

UNDER PANELS

59.1

49.1

A

A

SET IN CONCRETE

UNISTRUTP1000T

DETAILANCHOR

8"

3"

1'-0"

1112"

TYPICAL

SEE DETAIL

28°

4'-0"

TYP.

BURIAL DEPTH 80% + WET/COMPACT SOILCONCRETE @ HOLE BOTTOM, 3" STEEL COVER

PV MODULES

2x2x3/16 L SOUTH

4'-0"

C-C

TYP.

11'-4"

C-CTYP.

UNISTRUT P1000T HDGMETAL 2"x2"x3/16" HDG STEEL

BOLTS 1/2"x1" HDGTOUCH UP ALL CUTS/DRILL HOLES w/ RUSTOLEUM HARDHAT COLD GALV.

NOTES:

90°

5'-33 4"

6'-4 78 "

6'-47 8"

4'-0"

+-GND

600 VDC ratedFused Disc.

15A

Sunny Boy

4000 Inv.

30 AmpNema 3

Disc.

30

N

Gnd

NGnd

+ - + -+ - + -

-

+ -+ -

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

+-+- +- - + +-

+-

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D#

1

#2

#3

#4

#5

#6

Mo

d

Mo

d

Mo

d

Mo

d

Mo

d

Mo

d

#7

#8

#9

#1

0

#1

1

#1

2

Mo

d

Mo

d

Mo

d

Mo

d

Mo

d

Mo

d

Existing UtilityMeter

Inside Bldg Outside Bldg

Existing

House Panel

2 #10 eg in 1" Sch 40 PVC

Fused

3 #10 THWN & #10 eg in

3 #10 THWN & #10 eg in

150 Amp MCB

NOTES:

2 #10 USE-2 & #10 eg in

3. 30 Amp circuitbreaker to be

located in House Panel, as

required by NEC 690.64(B)(7).

1. 30 Amp Disc shall be loacated

adjacent to utility service entrance.

2. All signage shall be provided as

required by the NEC.

Gnd Rod

45' 8'

2 #10 OEM Type TC K2 90 C, 600v w/2 spare &

3/4" Sch 40 PVC

3/4" Sch 40 PVC

3/4" Sch 40 PVC

# 6 GEC

Nema 3 J-Box

4. All electrical connections are to be made in compliance with

manufacturer's specifications and NEC ed. 2008.

#10 eg (typ)

OEM MC type 4m cable, #10 USE-2 (typ)

http://www.kyocerasolar.com/pdf/specsheets/kd_205gx-lp_081508_web.pdf

OWNER: WIND LOAD:

DESIGNED FOR 110 MPH

LEGAL DESCRIPTION:

FOREST HILLS UNREC A TRACT IN NE1/4 OF

NE1/4 OF 33-21-20 AKA N1/2 OF TRACT 199

WIND EXPOSURE:

EXPOSURE CATEGORY B

SHEET NO:

DATE SAVED:

PUBLISHED:

SHEET NAME:

ALLEN GEZELMAN

16502 HANNA RD.

LUTZ, FLORIDA 33549

PH. 813 650 7246

FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

DRAWN:

06SCALE: N.T.S.

CONSTRUCTION DETAILS

SCALE: 1/4" = 1'-0"

ISOMETRIC PARTIAL EXPLODED ASSEMBLY

SCALE: 1/4" = 1'-0"

SECTION A

APPLICABLE CODE:

FLORIDA BUILDING CODE 2007

FLORIDA ELEC. 2007 CODE W/09 SUPP

REVISIONS:

THIS SHEET 1 OF 2

DESIGNED PER:ASCE 7-05

CHECKED:SB/JT AG

0025_Brooksville-Blackjack.dwg

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

William Daughrity

26330 Blackjack St

Brooksville, FL 34601

(352) 799-5117.

8/30/2009 9:42 PM

8/30/2009 9:42:34 PM

26330 Blackjack St. Brooksville, FL 34601

NEC 2008

05SCALE: N.T.S.

PV WIRING / SCHEMATIC

02SCALE: N.T.S.

PROPERTY LOCATION03

SCALE: N.T.S.

INSTALLATION LOCATION01

SCALE: N.T.S.

INSTALLATION NOTES

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEREQUIREMENTS OF THE CURRENTFLORIDA BUILDING CODE ANDNATIONAL ELECTRICAL CODE.

RATED VALUES FOR SOLAR WORLD,SW-175 PV MODULES *

• *QUANTITIES MEASURED @ 25 DEGREES CELSIUSPMAX=175 WVSC=44.4 VVMP=35.8 VISC=5.30 AIMP=4.89 A

MINIMUM AC & DC WIRING SIZE #10 AWG COPPER

(OEM WIRING & HARNESS EXCLUDED)

SMA SUNNY BOY 4000 GRID TIED INVERTER

Photo-Voltaic Solar Energy System Installation Notes:

This plan gives site-specific installation details for a photovoltaic (solar electric) system to be installed at the above location. The solar

modules shall be 12-each Koycera model KD205GX-LP wired in series. This shall be a grid-tied system using an SMA SunnyBoy model4000 inverter. Manufacturer information may be viewed at the following links:

http://www.kyocerasolar.com/pdf/specsheets/kd_205gx-lp_081508_web.pdf

http://www.sma-america.com/en_US/products/grid-tied-inverters/sunny-boy/sunny-boy-3000us-4000us.html

Wiring shall be as shown in Figure 03. All Contractor AC & DC wiring shall use 10 AWG copper (minimum). OEM wiring and harnesses,

regardless of wire size, are acceptable when applied to the OEM use intended such as PV-module to PV-module connections.

My wind calculations may be viewed at the following hyperlink: http://www.gezelmanpe.com/Installationdwgs.html

This plan may be viewed at a magnification of your choice at that site.

Special considerations:

• The PV modules will be installed as a ground-mount on the rack shown on this plan sheet.

• PV-modules produce electricity when exposed to sunlight. Keep covered with opaque material until all wiring is completed.

• Twisted (wire nut) connections are not permitted for DC wiring. Use OEM plug connector harness between PV modules. Terminate

in watertight junction or combiner boxes with screw terminals/busses at the electrical output end of the PV module strings

-multiple strings terminate in one box.

• Make solid mechanical connections to ensure electrical conductivity between all PV module enclosures and framing members with

no electrically isolated components, use #10 AWG bare copper with screwed connections for bonding jumpers as needed.

• Do not leave loose unsecured wires/harness between PV-modules, tie to the mounting rails or frame with UV resistant zip ties or

approved wire clips in neat, professional manner.

• Use approved means and methods per 2008 NEC

04SCALE: N.T.S.

SYSTEM CALCULATIONS & MANUFACTUER SPECS

SCALE: 1/4" = 1'-0"

FOUNDATION PLANSCALE: 1/4" = 1'-0"

PARTIAL FRAME PLAN

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

K A

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E A

CC

ES

SE

D A

T:

WW

W.G

EZ

ELM

AN

PE

.CO

M/P

V/0025_Brooksville-Blackjack.dwg

ENLARGED VIEWING & HYPERLINKS:PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS.

ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS ANDABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT:

WWW.GEZELMANPE.COM/PV/0025_Brooksville-Blackjack.dwg

THIS PLAN AND ITS USE ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTIONDOCUMENTS COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) . EJCDC C-700 MAY BE REVIEWED AT THE FOLLOWING HYPERLINK:

HTTP://WWW.DOUGLASAZ.GOV/PUBLICWORKS/DOCUMENTS/RFP/SEWER_REHAB_PHASE_I/00700%20-%20EJCDC.PDF

PV MODULE: HTTP://WWW.KYOCERASOLAR.COM/PDF/SPECSHEETS/KD_205GX-LP_081508_WEB.PDF

INVERTER:HTTP://WWW.SMA-AMERICA.COM/EN_US/PRODUCTS/GRID-TIED-INVERTERS/SUNNY-BOY/SUNNY-BOY-3000US-4000US.HTML

UNISTRUT: HTTP://WWW.UNISTRUT.COM/LITERATURE/INDEX.PHP?DOC=NO14&PG=1

UNIRAC (SOLARMOUNT MID CLAMP DETAILS ON PAGE 20): HTTP://WWW.UNIRAC.COM/PDF/II227.PDF

IN EVENT OF CONFLICT BETWEEN THIS PLAN AND OEM INSTRUCTIONS, OEM SHALL PREVAIL.

PV MODULES ANCHORED TO

UNISTRUT P1000T CHANNEL USING

UNIRAC SOLARMOUNT MID CLAMP

SHOWN IN PHOTO

THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL.

THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS.

EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN.

2.5 KW PV SYSTEM NOTES & CALCULATIONS

MODULES: KYOCERA KD205GX-LP, 205 WATTS X12 MODULES

MODULE PERFORMANCE CHARACTERISTICS:

PEAK POWER WP = 205 WATTSMAX. VOLTAGE VMP = 26.6 VOLTSMAX. CURRENT IMP = 7.71 AMPSVOC = 33.2 VOLTSISC = 8.36 AMPSMAX SERIES FUSE = 15 AMPS

** ALL MEASUREMENTS ARE AT STANDARD TEST CONDITIONS

OF 1000 WATTS/M2 IRRADIANCE AT 25 DEGREES C **

INVERTERS: SONNY BOY 4000

MAX INPUT VOLTAGE = 600 VOLTSDC MIN. VOLTAGE = 285 VOLTS

STRING INFORMATION:

1 STRINGS TOTAL; 12 MODULES CONNECTED IN SERIES,

VOC = 12 MODULES IN SERIES AT 33.2VOC = 12 X 33.2V = 398.4 VOLTSVMP = 12 MODULES IN SERIES AT 26.6VMP = 12 X 26.6V = 319.2 VOLTSISC = 8.36 AMPSIMP = 7.71 AMPSPOWER = 12 MODULES AT 205 WATTS = 12 X 205 W= 2460 WATTS

TEMPERATURE CORRECTION FOR CRYSTALLINE MODULES:

LOWEST RECORDED TEMPERATURE FOR FLORIDA IS -4 TO -4 DEG.F.PER NEC 2008-T690.7 MAX SYSTEM VOLTAGE CORRECTIONFACTOR OF 1.1812 PANELS IN SERIES X 33.2 VOC = 398.4V X 1.18= 470.1V470.1 < 600 VOLTS MAXIMUM ALLOWED. PASSED

MAXIMUM CURRENT:

OVER IRRADIATION:EACH STRING HAS AN ISC OF 8.36 AMPS

125% CORRECTION PER NEC 690.8(A)(1)= 8.36 AMPS X1.25=10.45 AMPS

CONTINUOUS CURRENT:

125% CORRECTION PER NEC 690.8(B)(1) =10.45 AMPS X 1.25= 13.1 AMPS

VOLTAGE DROP:

FROM 12 MODULE STRING TO INVERTER:

% VD = 2 (70FT) 1.29OHMS (13.1 AMPS) 100% / ((1000FT)

319.2V) %VD = 0.74%

CONDUCTOR AMPACITY #10 THWN:

NEC TABLE 310.16 W/CORRECTION FACTOR @ 40 DEG. C40 AMPS X .88 = 35.2 AMPS

NEC TABLE 310.16 W/CORRECTION FACTOR @ 40 DEG. C AND

TABLE 310.15(B) (2) (A) 4 COND. (IF FUTURE USE OF SPARES)

35.2 AMPS X .8 = 28.16 AMPS

01 APPLICATION # 1236137PLAN EXAMINER COMMENTS

01

01

01

FLORIDA SOLAR ENERGY CENTER CERTIFICATION NUMBER KC09-NT90-0239

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TOBY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.

ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE

THE BELOW ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL:

kyocerasolar.com FSEC CERTIFIED :KC09-NT90-0239

01

01

01

01

08.29.09

ELECTRICAL ENGINEER:

BRUCE A. TOZIER, P.E.

FMR. SGT. USMC

TOZIER ENGINEERING, INC.

209 S. GLEN ARVEN AVE.

TEMPLE TERRACE, FL 33617

OFF. (813) 988-3578

CELL (813) 951-4727

FAX (813) 988-3578

! NO COMBINER BOX NEEDED,

ONE STRING DESIGN !

01

01

01

01

01

01

dv8230us
Released

INSTALLATIONLOCATION OF

EXISTING SINGLE STORY HOME

B L A C K J A C K S T R E E T

D A N M

A R A V E N U E

E X I S

T I N

G

D R

I V E

W A

Y

,ON INTERIOR WALL.

Existing Fence Line

SHEET NO:

DATE SAVED:

PUBLISHED:

SHEET NAME:

ALLEN GEZELMAN

16502 HANNA RD.

LUTZ, FLORIDA 33549

PH. 813 650 7246

FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

DRAWN: CHECKED:JT AG

0025_Brooksville-Blackjack.dwg

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

8/30/2009 9:42 PM

8/30/2009 9:42:39 PM

26330 Blackjack St. Brooksville, FL 34601

01SCALE: 1/16"=1'-0"

PARTIAL SITE PLAN

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEREQUIREMENTS OF THE CURRENTFLORIDA BUILDING CODE ANDNATIONAL ELECTRICAL CODE.

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

K A

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E A

CC

ES

SE

D A

T:

WW

W.G

EZ

ELM

AN

PE

.CO

M/P

V/0025_Brooksville-Blackjack.dwg

OWNER: WIND LOAD:

DESIGNED FOR 110 MPH

LEGAL DESCRIPTION:

FOREST HILLS UNREC A TRACT IN NE1/4 OF

NE1/4 OF 33-21-20 AKA N1/2 OF TRACT 199

WIND EXPOSURE:

EXPOSURE CATEGORY B

APPLICABLE CODE:

FLORIDA BUILDING CODE 2007

FLORIDA ELEC. 2007 CODE W/09 SUPP

DESIGNED PER:ASCE 7-05

William Daughrity

26330 Blackjack St

Brooksville, FL 34601

(352) 799-5117. NEC 2008

THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL.

THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS.

EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN.

THIS SHEET 2 OF 2

01

THIS DRAWING IS THE LARGEST PRACTICABLE SCALE WHICH CAN REASONABLY

SHOW THE REQUIRED INFORMATION AND THE SPATIAL RELATIONSHIPS INVOLVED01 APPLICATION # 1236137

PLAN EXAMINER COMMENTS08.29.09

ELECTRICAL ENGINEER:

BRUCE A. TOZIER, P.E.

FMR. SGT. USMC

TOZIER ENGINEERING, INC.

209 S. GLEN ARVEN AVE.

TEMPLE TERRACE, FL 33617

OFF. (813) 988-3578

CELL (813) 951-4727

FAX (813) 988-3578

DIMENSIONS ON THIS PLAN HAVE BEEN OBTAINED

AND SCALED FROM HERNANDO PROPERTY APPRAISER

DATA. ACCURACY +/- 3% VERIFY DIMS IN FIELD

dv8230us
Released

Recommended