+ All Categories
Home > Documents > Anaerobic Digester Optimization NYWEA

Anaerobic Digester Optimization NYWEA

Date post: 07-Jul-2018
Category:
Upload: benjamin-long
View: 218 times
Download: 0 times
Share this document with a friend
32
8/19/2019 Anaerobic Digester Optimization NYWEA http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 1/32 Anaerobic Digester Optimization with Bio-Organic Catalyst ® NYWEA 81 st Annual Meeting February 3, 2009 One Year Study November ‘07 - November ‘08 2/2/09 1
Transcript
Page 1: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 1/32

Anaerobic Digester Optimization with Bio-Organic Catalyst ®

NYWEA 81 st Annual Meeting February 3, 2009One Year Study November ‘07 - November ‘08

2/2/09 1

Page 2: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 2/32

! Overview Ridgewood Water Pollution Control Facility

(WPCF)

!Description of Operating Baselines:

! Biogas Production

! Sludge Volumes

! Secondary Aeration Energy Usage

! Anaerobic Digestion Optimization with BOC

! Summary & Potential Economic Values

Municipal Anaerobic Digester OptimizationProgram Index

2/2/09 2

Page 3: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 3/32

The Village of Ridgewood located in Bergen County, New Jersey, is the fourth largest community in Bergen County, with a population of 25,500and land area of 5.79 square miles.

The Department of Public Works - Division of Water Pollution Control,operates the wastewater treatment plant (WPCF) and the sewagecollection system.

The Ridgewood, NJ WPCF receives an average daily flow of 2.6 - 3.0 MGD.

The sewage collection system is 92 miles in length, a combination of gravity and force mains. The lines range from 8 inches to 30 inches indiameter.

There are 6 pumping stations which pump influent flow into the WPCF.

The WPCF is operated as an activated sludge plant: with primary clarifiers,secondary aeration, secondary clarifiers, and anaerobic digester. It concentrates digested sludge prior to sending it off-site for incineration.

Water Pollution Control Facility Ridgewood, N.J.

02/02/09 3

Page 4: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 4/32

Ridgewood NJ WPCF Layout and BOC Injection Point

BOCInjection

Point

02/02/09 4 4

Page 5: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 5/32

Ridgewood NJ WPCFAnaerobic Digestion (AD) System

! The anaerobic digester functions in the mesophilic temperaturerange of 38.3 o C/101 oF.

! The anaerobic digester has a volume of 500,000 gallons/1893 cubicmeters.

! The baseline average primary feed sludge loading was 27,500gallons /104 cubic meters daily.

! The average HRT was 18.3 days.! Biomethane generated is burned in a boiler to heat incoming

primary feed sludge and to maintain the digester temperature.Excess biomethane is flared off.

! The clear liquid "supernatant" is withdrawn from the top of a500,000 gallons/1893 cubic meter holding tank and recycled to theinfluent wet well.

02/02/09 5

Page 6: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 6/32

Analytical Values of Anaerobic Digestion duringBOC Optimization Program

Anaerobic Digestion analytical values: Biomethane yields;

! Per cubic feet (CuFt 3) ! Per dry lb. of T.S. & T.V.S.! Per dry Kilo T.S. & T.V.S.! Per gal. of primary feed sludge.! Per 100 gals. of influent flow.

! Reduction/replacement in the consumption of natural gas in boilerheating anaerobic digesters (AD).

! Reduction of digester sludge volumes and weight.

! Reduction of aeration energy consumption in secondary aerationchannels, i.e. energy used (kWh/Lb of CBOD 5 ).! Reduction of volatile organics for odor reduction in digester dewatering

operation and dewatered sludge.

02/02/09 6

Page 7: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 7/32

Operating Baseline ValuesBOC Injection Period

02/02/0977

Page 8: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 8/32

Comparison Of Flows & Loading-Baseline Values Vs. BOC Injection Period

Influent Flow & LoadingConditions

BaselinePeriodAver.

03/07-7/07

BOC OptimumInjection PeriodAver.-3/08-7/08

Notes:Increased or (Decreased)

% Increase(Decrease )

Over Baseline

Influent Flow& LoadingConditions

Average DailyInfluent Flow

MGD 3.45 2.45 Decreased Decreased (29 %)(29 %)

100 GPD 34,510 24,559 Decreased Decreased

Cum 3 /Day 13,060 9,274 Decreased Decreased

Cum 3 /Sec 0.151 0.107 Decreased Decreased

TEMPERATURE TEMP.- 0C 19.1 17.9 Decreased Decreased (6.5 %)(6.5 %)

CBOD 5 mg/L 194.9 202.0 Increased 3.6%3.6%

T.S.S. mg/L 232.3 266.3 Increased 14.6%14.6%

AMMONIA-N mg/L 10.9 18.5 Increased 69.7%69.7%

TOTAL P mg/L 4.89 6.3 Increased 28.8%28.8%

Grit Removal CubicFt/Month

259 367 Improved

2/2/09 8

Page 9: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 9/32

Comparison Of Primary Effluent-Baseline Values Vs. BOC Injection Period

Primary Effluent ConditionsPrimary Effluent Conditions Baseline

Period Aver.03/07-7/07

BOCOptimumInjection

Period Aver.-3/08-7/08

Notes:Increased or (Decreased)

%Increase:

(Decrease)Over

Baseline

PrimaryEffluent

Primary Effluent:CBOD 5

mg/L 86.3 79.1 (Decreased)(Decreased) 8.3 %8.3 %

Primary Effluent:T.S.S.

mg/L 102 104.0 Increased 2 %2 %

% Removal Of CBOD 5

(Infl. vs. Primary Effluent) 56.2% 59.3 % Improved 5.5 %5.5 %

% Removal Of T.S.S.-(Infl. vs. Primary Effluent) 56.3 % 61.0 % Improved 8.3 %8.3 %

2/2/09 9

Page 10: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 10/32

Plant Effluent ConditionsPlant Effluent Conditions Baseline PeriodAver. 03/07-7/07

BOC OptimumInjection PeriodAver.-3/08-7/08

Notes:Increased or (Decreased)

% Increase(Decrease )

Over Baseline

PlantEffluent

CBOD 5 mg/L 7.1 6.8 (Decreased)(Decreased) 4.2%4.2%

CBOD 5 Removal % (Influent vs. Effluent) 96.3 % 96.5 % Improved 0.2%

T.S.S. mg/L 6.4 6.74

T.S.S.-Removal % (Influent vs. Effluent) 97.3 % 97.4 % Improved

D.O. mg/L 6.71 6.82 Improved

AMMONIA-N mg/L 1.25 .95 Improved 24.0%

AMMONIA-N-Removal %(Influent vs. Effluent) 88 % 94.5 % Improved 7.4%

Total P mg/L 2.98 3.46

Total P-Removal % (Influent vs.. Effluent) 40.4 % 42.6 % Improved 5.4%

2/2/09

Plant Effluent-Comparison Of Baseline ValuesVs. BOC Injection Period

10

Page 11: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 11/32

Comparison Of Biomethane Yields

(Baseline BOC Injection Period)

02/02/091111

Page 12: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 12/32

Comparison Of Biomethane Yields(Baseline & BOC Injection Period) !

2/2/09

Comparison Of Baseline vs.Comparison Of Baseline vs.Optimum BOC Injection PeriodOptimum BOC Injection Period

BaselinePeriodAver.

03/07-7/07

BOC OptimumInjection Period

Aver.-3/08-7/08

Notes:Increased

or (Decreased)

% Increase(Decrease)

Over Baseline

Daily Ave Cu m 3 of Bio-Gas Produced 609 1,031 Increased 69%

Daily Ave- CuFt 3 Of Biogas Produced 21,518 36,400 Increased 69%

HRT-Days 18.4 15.4 (Decreased) (16%)

Cu m 3 Biogas /Day Of HRT 33.1 67.3 Increased 103 %

Cu Ft3

of Biogas /Day Of HRT 1,167 2,376 Increased 103 %

% TS Reduction-(Max) 17.9% 27.2%( 65%) Increased 52%

% TVS Reduction with -(Max) 49.6% 54.0%(75%) Increased 8.9%

12

Page 13: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 13/32

Comparison Of Biomethane Yields(Baseline & BOC Injection Period) !

2/2/09

Comparison Of Baseline vs.Comparison Of Baseline vs.Optimum BOC Injection PeriodOptimum BOC Injection Period

BaselineBaselinePeriodPeriodAver.Aver.03/07-7/0703/07-7/07

BOC OptimumBOC OptimumInjection Period Injection Period

Aver.-3/08-7/08 Aver.-3/08-7/08

Notes:Notes:IncreasedIncreased

or or (Decreased)(Decreased)

% Increase% Increase(Decrease)(Decrease)

Over BaselineOver Baseline

TS Biogas Yield: Cu. ft 3 / Lb (DryRemoved) 8.5 15.9 Increased 87.1%

TS Biogas Yield:m 3 /Kilo (DryRemoved) 0.530 0.992 Increased 87.1%

TVS Biogas Yield: Cu.ft 3 / Lb (DryRemoved) 9.0 14.3 Increased 58.9%

TVS Biogas Yield:m 3 /Kilo DryRemoved 0.562 0.892 Increased 58.9%

Yield Of Biogas- Cu.ft 3 / 100 Gal Of Influent Flow .68 1.44 Increased 112%

13

Page 14: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 14/32

Increased Minimum & Daily AverageBiomethane Production (CuFt 3)

02/02/09 14

Page 15: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 15/32

Comparison Of Biomethane Yields(Baseline & BOC Injection Period) !

Comparison Of Baseline vs.Optimum BOC Injection Period

BaselinePeriod Aver.03/07-7/07

BOC OptimumInjection Period

Aver.-3/08-7/08

Notes:Increased

or (Decreased)

% Increase(Decrease)

Over Baseline

Gallons of primary sludge to AD-dailyaverage 27,172 32,433 Increased 19%

Daily average-cu ft 3 of biogas produced 21,518 36,400 Increased 69%

Daily Ave m 3 of Bio-Gas produced 609 1,031 Increased 69%

Cu Ft 3 Of bio-gas required heat primaryfeed sludge to aver. AD Temp. @ 600BTU’s / Cu Ft 3(*1 )

16,200 15,676 Decreased 3%

Daily Ave-BTU's Of Biogas Produced 12,910,800 21,840,000 Increased 95%

Daily BTU's required heat primary feedsludge to aver. AD temp. 8,100,070 9,405,563 Increased 16%

Excess daily biogas BTU’s produced 2,659,168 12,434,437 Increased 335%

Excess daily cu ft of biogas produced toheat primary feed sludge to aver. AD temp 5,318 20,724 Increased 263%

152/2/09

Page 16: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 16/32

Reduction Of NG Cost/ Month & ThermUsage with BOC Optimization

02/02/09 16

Page 17: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 17/32

Reduction In Total Cost and NG Therm Usage

02/02/09 17

Page 18: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 18/32

Comparison of Baseline Values & Lower NG Usage and Cost

02/02/09 18

Comparison Of Baseline vs.Optimum BOC Injection Period

BaselinePeriod Aver.03/07-7/07

BOC OptimumInjection Period

Aver.-3/08-7/08

Notes:Increased

or (Decreased)

% Increase(Decrease)

Over Baseline

Daily BTU's required to heat primaryfeed sludge to aver. AD temp. 8,100,070 9,405,563 Increased 16%

Excess daily cu ft of biogasproduced to heat primary feedsludge To aver. AD temp

5,318 20,724 Increased 263%

NG-Therms used daily aver 151 75 (Decreased)(Decreased) (101%)(101%)

NG-Therms/ M gallons of primaryfeed sludge 5.42 2.34 ((Decreased)Decreased) (132%)(132%)

Aver.-Nat Gas Cost/month $8,455.69 $ 2,953.76 (Decreased)(Decreased) (186% )(186% )

Excess daily biogas BTU’s produced 2,659,168 12,434,437 Increased 335%

Page 19: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 19/32

Reduction Of Sludge Volumes

02/02/0919

2/2/0919

Page 20: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 20/32

Comparison Of Baseline vs.....Optimum BOC Injection Period Baseline Period

Aver. 03/07-7/07

BOC OptimumInjection Period Aver.-

3/08-7/08

Influent Flow-MGD 3.45 2.45 ((28.9%)28.9%) Decreased Primary feed gallons per gallon

of influent flow 0.0085 0.0128 33.4% Increased

% Waste Haulage Gallons VsPrimary Feed Gallons 12.2% 9.1% (25.2%)(25.2%) Decreased

Primary Feed Sludge(GPD) 27,426 32,216 15% Increased

Primary Feed Sludge % T.S. 1.88% 1.81% (3.8%)(3.8%) Decreased Decreased

Primary Feed Sludge % T.V.S. 85.65% 85.21% (.5 %)(.5 %) Decreased Decreased

Sludge haulage daily gallon aver 3,166 2,713(14.3%)(14.3%) Decreased Decreased

Actual Sludge Haulage Volumereduction ( Corrected for

increased AD loading) 29.3% Decreased Decreased

Comparison of Sludge Baseline Values& BOC Injection Period

02/02/09 20

Notes: Increased

or (Decreased)

% Increase (Decrease)

Over Baseline

Page 21: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 21/32

02/02/0921

Reduction Of Secondary Aeration Energy

21

Page 22: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 22/32

Reduction Of Secondary Aeration Energy

There is a reduction of energy consumption within the facility’s aerationchannels from the “carry-over-effect” of the BOC injection into theanaerobic digester (AD) as the sludge thickening supernatant is returnedto the front end influent wastewater, thereby enhancing the transfer of

dissolved oxygen in secondary aeration channels.! This aeration energy savings provides an important secondary

economic value to the BOC process optimization of the anaerobicdigester (AD) application.

! The aeration energy savings offers the wastewater operator anadditional energy conservation strategy within a volatile energy

marketplace.! Overall aerobic processes and BNR exhibit positive performance

characteristics due to improvement of transfer of dissolved oxygenand management of optimum dissolved oxygen levels.

02/02/09 22

Page 23: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 23/32

Reduction Of Secondary Aeration Energy

! 20.8% reduction in Measured Demand On-Peak 1 kW.

! 24.5 % reduction in Measured Demand Off-Peak 1 kW.

! 19.7% reduction in Measured Demand Off-Peak 2 kW.

! 29.4% reduction in total kWh’s per Kg of CBOD 5 removed.

! 20% reduction in kWh’s used per day.

02/02/09 23

Page 24: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 24/32

Reducing Measured Peak and Off Peak kWh Usage

!"#

$%&

!"!

!'&

!$(

!"#

$!%

!#%

$%%

!&&

!!&

!'&

!(&

!#&

$&&

$!&

$'&

E34<A23? J3546?< /67F34G G) E34<A23? J3546?</HH7F34G7% G) E34<A23? J3546?</HH7F34G7! G)

.4<39*63K+42+ ;H

./01234+536+

F2;D245

/L+*5*M3? ./0 1234+536+ B3>39<

!&N# O P3?A:+*;6 *6E34<A23? J3546?</6 7F34G G)

02/02/09 24

Page 25: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 25/32

Reduced kWh's Usage Per Day, per Kg

02/02/09 252/2/09 25

Page 26: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 26/32

Secondary Aeration Energy SavingsPer Day & Annually

Based on the average prior baseline kWh usage of 5,224/day and thereduction of 1,000 kWh per day, daily and annual electrical savingsare calculated as follows:

The average daily energy cost (kWh) during the early baseline period

(12/15/06-1/16/07) was $.099/kWh, during which 5,224 kWh’s wereused. The prior average daily energy cost per day was $519.64.

During the BOC Optimization period the average daily energy cost roseto $.1327/kWh, or the equivalent of $693.22 per day

At a savings of 1,000 kWh daily, this translates to a savings of $132.67per day, and a savings of $48,424.55 per year.

02/02/09 26

Page 27: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 27/32

02/02/0927

Anaerobic Digestion OptimizationWith BOC

27

Page 28: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 28/32

The Anaerobic Digestion Sequence

02/02/09 28

Page 29: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 29/32

Anaerobic Digestion Optimization with BOC

The bio-catalytic action of BOC on the various organic componentsof a sludge waste stream, including the lipids, indicates that there is an accelerated release of high nutrient values toindigenous microbiological populations within the bio-digestersystem.

This leads to a faster transition to the Methanogenesis phase, alongwith higher microbiological vigor, producing a more completebiological consumption of TS & TVS.

This study showed a correlation to biomethane yield improvementsand TS & TVS consumption rates. This 1 year studydemonstrates these trend lines as optimization is reached.

Distinct qualitative characteristics of sludge discharged from ADexhibited substantial odor reductions, which follows from a morecomplete consumption of TVS components.

02/02/09 29

Page 30: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 30/32

Summary Of Results

02/02/093030

Page 31: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 31/32

Summary Of BOC Anaerobic DigestionOptimization

! 69% increased biogas production produced an annual savings of

$38,500 in NG purchases against the baseline period.

! Increased biomethane yields offer potential further annual NG savings

of $24,500 - $31,000 through a reduction, or elimination, of NG usage inBuilding Boiler.

! 29.3% reduction of sludge volumes offers projected savings annually of

$18,945.38.

! Reduction of secondary aeration energy usage on total kWh’s used perKg of CBOD 5 has been reduced by 29.4%, for a savings of $132.67 per

day, or a savings of $48,424.55 per year.

02/02/09 31

Page 32: Anaerobic Digester Optimization NYWEA

8/19/2019 Anaerobic Digester Optimization NYWEA

http://slidepdf.com/reader/full/anaerobic-digester-optimization-nywea 32/32

NEW YORK WATER ENVIRONMENT ASSOCIATIONNEW YORK WATER ENVIRONMENT ASSOCIATION

The study participants and authors would like to thank theNEW YORK WATER ENVIRONMENT ASSOCIATION for theopportunity to present this study on Anaerobic Digestion

Optimization at their 2009 Annual Meeting - February 3, 2009

NEW YORK WATER ENVIRONMENT ASSOCIATIONNEW YORK WATER ENVIRONMENT ASSOCIATION

Mr. Chris Rutishauser, P.E., CPWM, Village of RidgewoodMr. Bob Gillow, Superintendent, Village Of Ridgewood ,Water Pollution Control Facility

Mr. Greg Burde, Senior Sales Executive, Hydra-Numatic Sales Co.Mr. Jay Johnston, Executive Vice President, Bio-Organic Catalyst,Inc

Mr. Parker D. Dale, President, Bio-Organic Catalyst,Inc

02/02/09

32

2/2/09

32


Recommended