Auto Switch Guide
Applicable Cylinder Series
ø20
to
ø10
0C
HD
QB
P.1
262
ø20
, ø25
ø32
, ø40
CH
DK
DP
.128
4ø
50
ø63
to
ø10
0
ø32
to
ø10
0
ø20
, ø25
CH
DK
GP
.129
9
ø20
to
ø40
CH
NP
.131
7
ø20
to
ø40
CH
DM
P.1
336
ø40
, ø50
ø63
to
ø10
0C
HD
SD
P.1
353
ø32
ø40
to
ø80
ø10
0
CH
DS
GP
.136
4
ø32
ø40
to
ø10
0C
HD
2E
ø32
ø40
to
ø10
0C
HD
2F
ø32
ø40
to
ø10
0C
HD
2H
P.13
78, 1
404
ø40
, ø50
ø63
ø80
, ø10
0
CH
DA
P.1
416
D-C7/C8D-C73C/C80CD-B5/B6D-B59WD-A3/A4D-A7/A8D-A7H/A80HD-A73C/A80CD-A79WD-A5/A6D-A59WD-A9D-A9VD-Z7/Z8
D-H7D-H7CD-H7BAD-H7NFD-H7WD-G5/K5D-G5BAD-G59FD-G5NTD-G5W/K59WD-G39/K39D-F7/J7D-J79CD-F79FD-F7BAD-F7BAVD-F7VD-F7NTD-F7W(V)D-F5/J5D-F5BAD-F5W/J59WD-F59FD-F5NTD-M9D-M9VD-M9WD-M9WVD-M9AM9AVD-Y5/Y6/Y7/Y7VD-Y7BAD-Y7W/Y7WVD-F9G/H (Normally closed)D-Y7G/H (Normally closed)
Cylinder series
Bore size
Actuator page reference
Applicable Cylinder Series
So
lid s
tate
au
to s
wit
ches
Ree
d a
uto
sw
itch
es
1452
Best Pneumatics 8Auto Switch Variations
Function Type Electrical entry Auto switch model PageAuto switch
mounting style
Band
Rail
Tie-rod
Grommet
Connector
Terminal conduit
DIN terminal
Grommet
Connector
Grommet
1499
1500
1501
1502
1502
1503
1504
1505
1506
1466
1467
1468
1469
1470
1471
1472
1473
Band
Rail
Tie-rod
Grommet
Connector
Terminal conduit
Grommet
Connector
Grommet
D-H7A1/H7A2/H7B
D-G59/G5P/K59
D-H7C
D-G39/K39
D-F79/F7P/J79
D-F7NV/F7PV/F7BV
D-J79C
D-F59/F5P/J59/J51
Band mounting Rail mounting Tie-rod mounting
D-C73/C76/C80
D-B53/B54/B64
D-C73C/C80C
D-A33/A34
D-A44
D-A72/A73/A80
D-A72H/A73H/A76H/A80H
D-A73C/A80C
D-A53/A54/A56/A64/A67
Direct Grommet1498
1507
D-A90/A93/A96∗
D-A90V/A93V/A96V∗
D-Z73/Z76/Z80∗∗
∗ These auto switches can be mounted with a band, a rail, a tie-rod or a square groove when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
∗∗ These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
1462
1463
1464
1465
Direct Grommet
D-M9N/M9P/M9B∗
D-M9NV/M9PV/M9BV∗
D-F9G/F9H (Normally closed)∗
D-Y59A/Y59B/Y7P∗∗
D-Y69A/Y69B/Y7PV∗∗
D-Y7G/Y7H (Normally closed)∗∗
Auto Switch Variations 1
Gen
eral
pu
rpo
se a
uto
sw
itch
es
So
lid s
tate
Ree
d
1453
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
Band mounting Rail mounting Tie-rod mounting Direct mounting
OFFOperatingrange
ON
Red Green Red
Proper operating range
GreenRed
Red
A green light lights upat the proper operating range.
Auto Switch Guide
Auto Switch Variations
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
D-H7NW/H7PW/H7BW
D-G59W/G5PW/K59W
D-F79W/F7PW/J79W
D-F7NWV/F7BWV
D-F59W/F5PW/J59W
1476
1477
1478
1479
1480
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
D-B59W
D-A79W
D-A59W
1508
1509
1510
∗ These auto switches can be mounted with a band, a rail, a tie-rod or a square groove when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
∗∗ These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
Function Type Electrical entry Auto switch model PageAuto switch
mounting style
Direct Grommet
D-M9NW/M9PW/M9BW∗
D-M9NWV/M9PWV/M9BWV∗
D-Y7NW/Y7PW/Y7BW∗∗
D-Y7NWV/Y7PWV/Y7BWV∗∗
1474
1475
2-color indication
Auto Switch Variations 2
Even if 2-color indication solid state auto switches are fixed at the proper operating range (the green light lights up), the operation may become unstable depending on the installation environment or magnetic field disturbance. (Magnetic body, external magnetic field, proximal installation of cylinders with built-in magnet and actuators, temperature change, other factors for magnetic force fluctuation during operation, etc.)
So
lid s
tate
Ree
d
2-co
lor
ind
icat
ion
Easily identifiable, proper operating rangeMounting positions can be set easily. Proper operating ranges can be set while watching the lights.
Displacement of the detecting position can be visually checked. Trouble caused by incorrect detection can be prevented beforehand.
1454
Best Pneumatics 8
2-color indication type with diagnostic output Water resistant 2-color indication type With timer
Auto Switch Variations
Function Type Electrical entry Auto switch model PageAuto switch
mounting style
2-co
lor
ind
icat
ion
auto
sw
itch
wit
hd
iag
no
stic
ou
tpu
t
The diagnostic output signal can be detected in an unsteady detecting area.
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
D-H7NF
D-G59F
D-F79F
D-F59F
1481
1482
1483
1484
Wat
er r
esis
tan
t 2-
colo
rin
dic
atio
n a
uto
sw
itch
Water resistant (coolant) type
So
lid s
tate
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
1487
1488
1489
1490
Auto
sw
itch
with
tim
er
With built-in OFF-delay timer (200 ms)
Sol
id s
tate
D-H7BA
D-G5BA
D-F7BA
D-F7BAV
D-F5BA
So
lid s
tate
Direct Grommet1485
1486
D-M9A∗
D-M9AV∗
D-Y7BA∗∗
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
D-G5NT
D-F7NT
D-F5NT
1491
1492
1493
∗ These auto switches can be mounted with a band, a rail, a tie-rod or a square groove when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
∗∗ These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. For details, refer to “How to Mount and Move the Auto Switch” of each series.
1455
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
Prior to UseAuto Switches Common Specifications 1
Auto Switches Common Specifications
Type
Leakage current
Operating time
Impact resistance
Insulation resistance
Withstand voltage
Ambient temperature
Enclosure
Reed auto switch
None
1.2 ms
300 m/s2
1500 VAC for 1 minute ∗1)
(Between lead wire and case)
Solid state auto switch
3-wire: 100 µA or less, 2-wire: 0.8 mA or less
1ms or less ∗3)
1000 m/s2 ∗4)
1000 VAC for 1 minute
(Between lead wire and case)
50 MΩ or more (500 VDC measured via megohmmeter) (Between lead wire and case)
−10 to 60°C
IEC60529 Standard IP67 ∗2)
Refer to the Auto Switch Precautions on pages 1237 to 1241 before using auto switches.
∗ 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min.(Between lead wire and the case)
∗ 2) The terminal conduit type (D-A3/A3A/A3C/G39/G39A/G39C/K39/K39A/K39C), DIN terminal type (D-A44/A44A/A44C) and heat resistant auto switch (D-F7NJ) conform to IEC60529 Standard IP63. The trimmer type amplifier section (D-RK) conforms to IP40.
∗ 3) Excluding the solid state auto switches with a timer (D-M5T/G5NT/F7NT/F5NT types) and magnetic field resistant 2-color indication solid state auto switch (D-P3DW/P4DW).The operating time for D-J51 is 2 ms or less and for D-P3DW/P4DW are 40 ms or less.
∗ 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.
Lead wire length indication
L(Example)
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
Part No. of Lead Wires with Connectors(Applicable only for connector type)
D-M9BW
NilMLZ
N ∗1)
SAPCMAPCSBPCMBPCSDPCMDPCLDPC
Length0.5 m1 m3 m5 m
None0.5 m1 m
0.5 m1 m
0.5 m1 m3 m
Tolerance±15 mm±30 mm±90 mm
±150 mm−
±15 mm±30 mm±15 mm±30 mm±15 mm±30 mm±90 mm
Connector Specifications
M8-3 pinPlug connector
M8-4 pinPlug connector
M12-4 pin A code (Normal key)Plug connector
Solid state
∗2)
Reed
−
∗3)
−−−−−−−
Symbol
Lead wire length
: Standard : Produced upon receipt of order (Standard)
∗ 1) Applicable to the connector type (D-C) only.∗ 2) Applicable to the D-M9 (V), D-M9W (V), and D-M9A (V) only.∗ 3) Applicable to the D-B53/B54, D-C73(C)/C80C, D-A93(V), D-A73(C)/A80C, D-
A53/A54, D-Z73, and D-90/97/90A/93A only.∗ 4) For reed auto switches M8 and M12 type with connector, please contact SMC.∗ 5) The standard lead wire length of the trimmer auto switch is 3 m.∗ 6) The standard lead wire length of the solid state auto switch with the timer except
for the D-P3DW and D-M9A (V), water-resistant 2-color display solid state auto switch, wide range detection auto switch, heat resistant 2-color display solid state auto switch, and strong magnetic field resistant 2-color display solid state auto switch is 3 m or 5 m. (Product with a lead wire length of 0.5 m is not avail-able.)
Auto switchmodel
Lead Wire
Lead wires with a connector indication
1456
Prior to UseAuto Switches Common Specifications 2
Refer to the Auto Switch Precautions on pages 1237 to 1241 before using auto switches.
A position (sensor layout position) where the sensitivity is highest on the detection surface of the auto switch enclosure.When the center of the magnet is aligned with this position, this becomes almost the center of the operating range and stable operation can be obtained.
One of elements making up the sequence control.The PLC is so designed that it receives signals, such as auto switch output and outputs them to other devices so as to perform the electrical control according to the preset program.
A temperature range, in which the auto switch can be used.If significant temperature change or freezing occurs even in this temperature range, this may cause the auto switch to malfunction.
A voltage, at which the auto switch can be used.The operating voltage is indicated using generally used voltage (24 VDC or 100 VAC, etc.).For 2-wire type, the operating voltage has the same meaning as the power supply voltage or load voltage.
A range of the current value that can be flowed to the output of the auto switch.If the operating current is lower than this range, the auto switch does not operate correctly. Conversely, if the operating current is higher than this range, this may cause the auto switch to break.
This current value is necessary for the 3-wire type auto switch to operate the circuit through the power cable.For 2-wire type, as the current consumption is a part of the load current, it is not defined.
A resistance between the electric circuit and enclosure.Unless otherwise described particularly, 50MΩ (Min) is used for auto switch.
An auto switch, for which measures against effects arising from external (welding) magnetic field generated in the spot weld-ing process, etc. are taken.The solid state auto switch functions as it detects the frequency of the applied magnetic field. If the external magnetic field (AC) is applied, the last signal is retained not to be affected by the external magnetic field. This system can be used by the cylinder with normal magnetic force.The reed auto switch built-in a magnetic field shielded sensor with a low sensitivity to make the effect of the external mag-netic field (DC or AC magnetic field) insusceptible. Therefore, a dedicated cylinder built-in the strong magnet needs to be selected and there is also an operable range (conditions).
A minimum acceleration that may cause the auto switch to malfunction or break when the standard impact is applied.
A model, long-term water resistance of which is improved by taking structural measures for the general (general purpose) product.
A tolerance dose when the voltage is applied to the portion between the electrical circuit and enclosure.The withstand voltage shows a strength level of the product against the voltage. If a voltage exceeding the withstand voltage is applied, this may cause the product to break. (The voltage described here is different from the power supply voltage nec-essary to operate the product.)
A dimension that shows the mounting position when the position is detected at the stroke end of the cylinder.As this position is set, the maximum sensitivity position is aligned with the center of the magnet. However, make the adjust-ment with the actual machine by considering the characteristic difference during actual setting.When an adjustment allowance is needed for the detection before the stroke, set a value with an adjustment allowance added to the proper mounting position.
A device that is assumed as a target load of the auto switch.
A period of time until the auto switch output becomes stable after the magnetic force to operate the auto switch has been received.
An auto switch operating range in response to the cylinder piston movement (ON length in response to the stroke). The oper-ating range is determined by the magnetic force of the magnet (range, in which the magnetic force acts) and switch sensitivity. So, the operating range may vary as these conditions are changed by the ambient environment, etc.The operating range in the standard status (normal temperature, single cylinder, magnetic force, and sensitivity, etc.) is described in the catalog.
Note) Hysteresis may fluctuate due to the operating environment.Please contact SMC if hysteresis causes an operational problem.
MeaningTerm
Hysteresis Auto switch
Switch operating position(ON) Hysteresis Reed auto switch: 2 mm or less
Solid state auto switch: 1 mm or less
Switch operating position(OFF)
Most sensitive position
Programmable LogicController (PLC)
Operatingtemperature range
Operating voltage
Operatingcurrent range
Current consumption
Insulation resistance
Magnetic field resistantauto switch
Impact resistance valueWater-resistant type auto switchWithstand voltage
Proper mountingposition
Operating range
Operating timeApplicable load
A deviation amount between the ON position and OFF position caused by auto switch characteristics (difference in sensitivity between ON and OFF).When the switch is turned ON once and the switch (or piston) is moved in the opposite direction, a symptom occurs that the position where the switch turns OFF deviates to a position where it is further returned from the ON po-sition. This deviation amount is called “hysteresis”.
1457
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Prior to UseAuto Switches Common Specifications 3
Refer to the Auto Switch Precautions on pages 1237 to 1241 before using auto switches.
A switch that detects the magnetic field by the MR element and incorporates the judgement circuit to turn ON or OFF the out-put regardless of the contact or non-contact of the mechanical contact like transistor (non-contact part).A current that flows to operate the internal circuit when the ON-OFF output is OFF. In particular, if this leak current exceeds the detection current in the 2-wire type auto switch or PLC, this may cause reset fault. So, take great care when selecting a device.A switch that uses the reed switch to detect the magnetic field and turn ON or OFF the output by the contact or non-contact of the mechanical contact (contact part is provided like relay or limit switch).
A load that has the coil. The connection target of the auto switch is a relay.A minimum bending radius (reference value) of the lead wire when the lead wire is secured and constructed (oscillation or ro-tation is not considered).(As the temperature or current value conforms to the auto switch specifications, this lead wire bending radius differs from the value disclosed by the electric wire manufacturer.)A structure, in which the lead wire of the auto switch is taken out in the horizontal direction when the cylinder is laid out hori-zontally (cylinder rod is horizontal), is called “in-line entry”. A structure, in which the lead wire is taken out in a direction per-pendicular to the cylinder axis center, is called “perpendicular entry”.
MeaningTerm
Minimum Stroke forAuto Switch Mounting
Internal voltage drop
Solid state auto switch
Leak current
Reed auto switch
Induction loadRecommended leadwire bending radius
Electrical entry
2-Color Indication
Load
Load current
Enclosure
IP
First characteristic numeral
Second characteristic numeral
Example) In the case of stipulated as IP65, we can know the degrees of protection is dusttight and water jet-proof on the grounds that the first characteristic numeral is 6 and the second characteristic numeral is 5 respectively, that gives it will not be adversely affected by direct water jets from any direction.
Non-protectedProtected against vertically falling water dropsProtected against vertically falling water drops when enclosure tilted up to 15°Protected against rainfall when enclosure tilted up to 60°Protected against splashing waterProtected against water jetsProtected against powerful water jetsProtected against the effects of temporary immersion in waterProtected against the effects of continuous immersion in water
01
2
345678
Second Characteristics: Degrees of protection against water
Non-protectedProtected against solid foreign objects of 50 mm ø and greaterProtected against solid foreign objects of 12 mm ø and greaterProtected against solid foreign objects of 2.5 mm ø and greaterProtected against solid foreign objects of 1.0 mm ø and greaterDust-protectedDusttight
0123456
First Characteristics: Degrees of protection against solid foreign objects
A minimum stroke value of the auto switch that can be mounted on the cylinder.The minimum stroke is determined by the specification limit (auto switch operation or position setting ability, etc.) and physi-cal limit (mechanical interference associated with the auto switch mounting).Note that the catalog shows the value assuming that the position detection is performed at the stroke end and this value does not consider the adjustment allowance.When an adjustment allowance is needed, such as detection before the stroke, a value is set that this adjustment allowance is added to the minimum stroke.
A voltage that is applied to the portion between the COM and signal line when the auto switch is ON.As only a value that the internal voltage drop is subtracted from the power supply voltage is applied to the input side of the PLC, the detection fault (incorrect input) may occur if this value is lower than the minimum operating voltage. So, take great care when selecting a device.
As the end part of the auto switch operating range (boundary between ON and OFF) is an area where is susceptible to the external disturbance or stroke change during cylinder operation, this function is intended to quickly and properly make the setting at the center of the operating range where the stable operation can be obtained by changing the operation indication color of the auto switch.
A device that is connected to the output of the auto switch so as to do any work is called “load”.For example, the load is a relay or PLC, etc.To check the operation of the auto switch, a device equivalent to the load (such as resistor, etc.) is connected.
A current that flows to the load when the ON-OFF output is ON.
A class of protection against solid or water entry of the electrical machinery and apparatus specified in IEC60529.
1458
Reed Auto Switches
Solid State Auto Switches
Contact Protection Box/CD-P11, CD-P12
Contact Protection Box SpecificationsPart no.
Load voltage
Max. load current
CD-P11 CD-P12
∗Lead wire length — Auto switch connection side 0.5 m Load connection side 0.5 m
100 VAC or less
25 mA
200 VAC
12.5 mA
24 VDC
50 mA
To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire
coming out of the switch unit. Keep the switch as close as possible to the contact protection box, with a lead wire length of no more than 1 meter.
Contact Protection Box Connection
Contact Protection Box/Dimensions
Contact Protection Box Internal Circuit
<Applicable switch models>D-A7/A8, D-A7H/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, D-A79WThe auto switches above do not have a built-in contact protection circuit.A contact protection box is not required for solid state auto switches due to their construction.1. Where the operation load is an inductive load.2. Where the wiring length to load is greater than 5 m.3. Where the load voltage is 100/200 VAC.
Therefore, use a contact protection box with the switch for any of the above cases:The contact life may be shortened (due to permanent energizing conditions.)D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads.(Where the load voltage is 110 VAC)When the load voltage is increased by more than 10% to the rating of applicable auto switches (except D-A73C/A80C/C73C/C80C/90/97/A79W) above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the range of the load current range, 110 VAC.
Even for the built-in contact protection circuit type (D-A34[A][C], DA44[A][C], D-A54/A64, D-A59W, D-B59W), use the contact protection box when the wiring length to load is very long (over 30 m) and PLC (Programmable Logic Controller) with a large inrush current is used.
CD-P11
CD-P12
Prior to UseAuto Switches/Internal Circuit
2-Colorindication
circuit
2-wire (Reed switch)
Load
2-wire (Reed switch)
Load2-Colorindication
circuitLoad
Black
2-wire (Reed switch)
LoadContactprotection
box
Contactprotection
box
Contactprotection
box
2-wire (Reed switch)
Load
3-wire (Reed switch, NPN)
Indicatorcircuit
Indicatorcircuit
2-wire (Reed switch)
LoadContactprotection
circuit
Contactprotection
circuit
Contactprotection
circuit
2-wire (Reed switch)
Load
Brown
Blue Blue
Blue
(Power supply for switch and load are separate)
2-wire (Solid state)Solid state 3-wire, PNPSolid state 3-wire, NPN
Load
Load
LoadLoad
Load
Blue
BlueBlue
Black
Blue
Black
Blue
BlackBrown Brown Brown
BrownBrown
Main curcuitof switch
Main curcuitof switch
Main curcuitof switch
Main curcuitof switch
Main curcuitof switch
No.
Circ
uit d
iagr
amC
ircui
t dia
gram
No.
Indicatorcircuit
Brown Brown
BrownBrownBrown
Brown
Blue
Blue
Blue
Blue
Brown
Blue Blue(−)
Brown(+)
Load sideAuto switch sideChoke coilZenerdiode
Brown
Blue Blue(∼)
Brown(∼)
Load sideAuto switch sideChoke coilSurgeabsorber
1459
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Input
COM
COM
Input
COM
Input
COM
Input
(PLC internal circuit)
(PLC internal circuit)
(PLC internal circuit)
(PLC internal circuit)
2-wire
3-wire, PNP
2-wire
3-wire, NPN
Blue
Brown
Blue
Brown
Blue
Black
Brown
Blue
Black
Brown
Auto switch
Auto switch
Auto switch
Auto switch
Relay
Relay
3-wire OR connection for PNP output
(Performed with auto switches only)(Using relays)
3-wire AND connection for PNP output
3-wire OR connection for NPN output(Performed with auto switches only)(Using relays)
3-wire AND connection for NPN output
Load
Load
Load
Load Load
Load
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
Blue
Black
Brown
Auto switch 2
Blue
Black
Brown
Auto switch 1
2-wire OR connection2-wire AND connection
Load Load
Blue
Brown
Auto switch 2
Blue
Brown
Auto switch 1
Blue
Brown
Auto switch 2
Blue
Brown
Auto switch 1
Prior to UseAuto Switch Connection and Example
Example of AND (Series) and OR (Parallel) Connection
Sink Input Specifications Source Input Specifications
Load voltage at ON = Power supply voltage – Residual voltage x 2 pcs.
= 24 V − 4 V x 2 pcs.= 16 V
Example: Power supply is 24 VDCInternal voltage drop in auto switch is 4 V.
Load voltage at OFF = Leakage current x 2 pcs. x Load impedance
= 1 mA x 2 pcs. x 3 kΩ= 6 V
Example: Load impedance is 3 kΩ.Leakage current from auto switch is 1 mA.
(Solid state) (Reed)When two auto switches are connected in series, a load may malfunction because the load voltage will decline when in the ON state.The indicator lights will light up when both of the auto switches are in the ON state.Auto switches with load voltage less than 20V cannot be used.
When two auto switches are connected in parallel, malfunction may occur because the load voltage will increase when in the OFF state.
Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches.
Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications.
∗ When using solid state auto switches, ensure the application is setup so the signals for the first 50 ms are invalid.
1460
FunctionType Electrical entry Auto switch model PageAuto switch
mounting style
Gen
eral
pu
rpo
se
Band
Rail
Tie-rod
Grommet
Connector
Terminal conduit
Grommet
Connector
Grommet
2-co
lor
ind
icat
ion
2-co
lor i
ndic
atio
n wi
th d
iagn
ostic
ou
tput
With
tim
erW
ater
res
ista
nt
2-co
lor
ind
icat
ion
1466
1467
1468
1469
1470
1471
1472
1473
D-H7A1/H7A2/H7B
D-G59/G5P/K59
D-H7C
D-G39/K39
D-F79/F7P/J79
D-F7NV/F7PV/F7BV
D-J79C
D-F59/F5P/J59/J51
D-H7NF
D-G59F
D-F79F
D-F59F
D-H7BA
D-G5BA
D-F7BA
D-F7BAV
D-F5BA
Grommet
Grommet
Grommet
Grommet
Grommet
Grommet
Band
Rail
Tie-rod
Band
Rail
Tie-rod
D-H7NW/H7PW/H7BW
D-G59W/G5PW/K59W
D-F79W/F7PW/J79W
D-F7NWV/F7BWV
D-F59W/F5PW/J59W
1476
1477
1478
1479
1480
Grommet
Grommet
Grommet
Band
Rail
Tie-rod
D-G5NT
D-F7NT
D-F5NT
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
1491
1492
1493
1487
1488
1489
1490
1481
1482
1483
1484
So
lid S
tate
Au
to S
wit
ch
D-M9N/M9P/M9B
D-M9NV/M9PV/M9BV
D-F9G/F9H (Normally closed)
D-Y59A/Y59B/Y7P
D-Y69A/Y69B /Y7PV
D-Y7G/Y7H (Normally closed)
Direct Grommet
1462
1463
1464
1465
Direct Grommet
D-M9NW/M9PW/M9BW
D-M9NWV/M9PWV/M9BWV
D-Y7NW/Y7PW/Y7BW
D-Y7NWV/Y7PWV/Y7BWV
1474
1475
D-M9NA/M9PA/M9BA
D-M9NAV/M9PAV/M9BAV
D-Y7BA
GrommetDirect1485
1486
Solid State Auto Switch Variations
Solid State Auto SwitchesGeneral Purpose Type, 2-color Indication Type, 2-color Indication Type with Diagnostic Output, Water Resistant 2-color Indication Type, Timer Equipped Type, Wide Range Detection Type
1461
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
PrecautionsCaution
Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.
Weight
Auto switch model
0.5 m (Nil)1 m (M)
3 m (L)
5 m (Z)
8
14
41
68
D-M9P(V) D-M9B(V)D-M9N(V)7
13
38
63
(g)
Lead wire length
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
DimensionsD-M9 D-M9V
2-wire load current is reduced (2.5 to 40 mA).
Flexibility is 1.5 times greater than the conventional model (SMC comparison).
Using flexible cable as standard spec.
(mm)
2 cores (Brown/Blue)
Auto switch model D-M9N D-M9P D-M9B
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
2.7 x 3.2 (ellipse)
ø0.9
0.15
ø0.05
20
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto SwitchDirect Mounting StyleD-M9N(V)/D-M9P(V)/D-M9B(V)
Auto Switch Specifications
Auto switch model D-M9NVD-M9N D-M9B D-M9BV
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less
D-M9PVD-M9P
Red LED illuminates when turned ON.
CE marking, RoHS
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
10 mA or less
40 mA or less
0.8 V or less at 10 mA (2 V or less at 40 mA)
100 µA or less at 24 VDC
In-line Perpendicular In-line Perpendicular In-line Perpendicular
NPN PNP
28 VDC or less —
D-M9, D-M9V (With indicator light)PLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
M2.5 x 4 L
2.7
22
2.6
4
2.8
3.2
6
Slotted set screw
Indicator light
Most sensitive position
4
2.6
9.5
2.7
4.62
20
M2.5 x 4 L
2.8
83.2
4
Indicator lightSlotted set screw
6 Most sensitive position
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
1462
Weight (g)
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-F9G D-F9H7
37
61
Lead wire length
PrecautionsCaution
Output signal turns on when no magnetic force is detected.
Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.
Auto switch model D-F9G D-F9HSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø2.7
3 cores (Brown/Blue/Black)
ø0.91
0.15
ø0.08
17
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Normally Closed Solid State Auto SwitchDirect Mounting StyleD-F9G/D-F9H
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F9G, D-F9H (With indicator light)D-F9G
NPN
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less at 10 mA load current)
D-F9H
PNP
—
80 mA or less
0.8 V or less
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Red LED illuminates when detecting nothing.
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Dimensions (mm)
M2.5 x 4 L
4
SMC D-F9H NC
2.8
22
2.6
6
ø2.
7
2
Slotted set screw
Indicator light
Most sensitive position
Auto switch model
1463
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-Y59B D-Y69BD-Y69AD-Y59A D-Y7P(V)
9
50
83
10
53
87
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Most sensitive position
Grommet
Using flexible cable as standard spec.
2 cores (Brown/Blue)
Auto switch model D-Y9A D-Y7P D-Y9B
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.0
0.15
ø0.05
21
Oilproof Flexible Heavy-duty Lead Wire Specifications
RoHS
Auto Switch Specifications
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-Y5, D-Y6, D-Y7P, D-Y7PV (With indicator light)D-Y59A
In-line
Red LED illuminates when turned ON.
CE marking, RoHS
D-Y69A
Perpendicular
D-Y69B
Perpendicular
D-Y7PV
Perpendicular
D-Y59B
In-line
D-Y7P
In-line
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
1.5 V or less(0.8 V or less
at 10 mA load current)
100 µA or less at 24 VDC
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
NPN
28 VDC or less
40 mA or less
PNP
—
80 mA or less
0.8 V or less
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
3-wire
Dimensions (mm)
D-Y59A/D-Y7P/D-Y59B D-Y69A/D-Y7PV/D-Y69B
SM
C
SM
C
6.2
5
2.5
29
ø3.
4
12.5
27.3
6.2
5
12.5
8.5
2.5
ø3.4
Most sensitive position
M2.5 x 4 L
Slotted set screw
Slotted set screw
Indicator light
Indicator light
Most sensitive position
M2.5 x 4 L
Auto switch model
AB
AB
Solid State Auto SwitchDirect Mounting StyleD-Y59 /D-Y69 /D-Y7P(V)
1464
Weight (g)
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-Y7G D-Y7H10
53
87
Lead wire length
Most sensitive position
Auto switch model
D-Y7G, D-Y7H (With indicator light)D-Y7G
NPN
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less at 10 mA load current)
D-Y7H
PNP
—
80 mA or less
0.8 V or less
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Red LED illuminates when detecting nothing.
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Output signal turns on when no magnetic force is detected.
Using flexible cable as standard spec.
Auto switch model D-Y7G D-Y7HSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
3 cores (Brown/Blue/Black)
ø1.0
0.15
ø0.05
21
Oilproof Flexible Heavy-duty Lead Wire Specifications
RoHS
Normally Closed Solid State Auto SwitchDirect Mounting StyleD-Y7G/D-Y7H
SM
C
D-Y7G
NC6.2
5
2.5
29
ø3.
4
12.5
M2.5 x 4 LSlotted set screw
Indicator light
Dimensions (mm)
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
1465
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Dimensions (mm)
Indicator light
ø3.5 mounting hole
Most sensitive position
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
57
92
11
50
81
D-H7A1 D-H7A2 D-H7B
(g)
Grommet
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-H7A1 D-H7A2 D-H7B
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto SwitchBand Mounting StyleD-H7A1/D-H7A2/D-H7B
D-H7 (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-H7A1
NPN
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA load current)
D-H7A2
PNP
—
80 mA or less
0.8 V or less
Red LED illuminates when turned ON.
CE marking, RoHS
D-H7B
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
1466
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
20
78
124
18
68
108
D-G59 D-G5P D-K59
(g)
Grommet
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-G59 D-G5P D-K59
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto SwitchBand Mounting StyleD-G59/D-G5P/D-K59
D-G5, D-K59 (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-G59
NPN
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA load current)
D-G5P
PNP
—
80 mA or less
0.8 V or less
Red LED illuminates when turned ON.
CE marking, RoHS
D-K59
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Dimensions (mm)
Indicator light
ø4.5 mounting hole
Most sensitive position
1467
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
15
54
85
D-H7C
(g)
Connector
Lead wire length
1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. Refer to Best Pneumatics No.2 for the details.
PrecautionsCaution
Lead wires with a connector indication
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
Part No. of Lead Wires with Connectors(Applicable only for connector type)
RoHS
D-H7C (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-H7C
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Dimensions (mm)
Indicator light
ø3.5 mounting hole
Most sensitive position
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Lead wires with a connector may be shipped with switches.
Solid State Auto SwitchBand Mounting StyleD-H7C
1468
Terminal conduit
RoHS
Solid State Auto SwitchBand Mounting StyleD-G39/D-K39
1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance.
2. After wiring, confirm that tightening gland and all screws are tightened.
PrecautionsCaution
D-G39, D-K39 (With indicator light)Auto switch model D-G39
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA of load current)
100 µA or less at 24 VDC
D-K39
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Note) Refer to page 1456 for solid state auto switch common specifications.
Red LED illuminates when turned ON.
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Auto switch model
None 116
D-G39 D-K39
Weight (g)
Lead wire
Dimensions (mm)
(Applicable cable O.D. ø6.8 to ø9.6)
Tightening gland
G (PF) 1/2
Indicator light Most sensitive position
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
1469
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-F79 D-F7P D-J79
(g)
Grommet
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
11
50
81
13
57
92
2 cores (Brown/Blue)
Auto switch model D-F79 D-F7P D-J79
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto SwitchRail Mounting StyleD-F79/D-F7P/D-J79
Auto Switch Specifications
D-F7, D-J79 (With indicator light)PLC: Programmable Logic Controller
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F79
NPN
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA load current)
D-F7P
PNP
—
80 mA or less
0.8 V or less
Red LED illuminates when turned ON.
CE marking, RoHS
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
D-J79
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Refer to SMC website for the details of the products conforming to the international standards.
Dimensions (mm)
Indicator light
Most sensitive position
ø3.2 mounting hole
1470
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
57
92
11
50
81
D-F7NV D-F7PV D-F7BV
(g)
GrommetElectrical entry: Perpendicular
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-F7NV D-F7PV D-F7BV
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
D-F7V (With indicator light)Auto switch model D-F7NV
NPN
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA load current)
D-F7PV
PNP
—
80 mA or less
0.8 V or less
Red LED illuminates when turned ON.
CE marking, RoHS
D-F7BV
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
PLC: Programmable Logic Controller
Dimensions (mm)
Indicator light
Most sensitive position
ø3.2 mounting hole
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
Solid State Auto SwitchRail Mounting StyleD-F7NV/D-F7PV/D-F7BV
1471
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
52
83
D-J79C
(g)
Connector
Lead wire lengthLead wires with a connector indication
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
Part No. of Lead Wires with Connectors(Applicable only for connector type)
RoHS
Solid State Auto SwitchRail Mounting StyleD-J79C
1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. Refer to page Best Pneumatics No.2 for the details.
PrecautionsCaution
D-J79C (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-J79C
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
PLC: Programmable Logic Controller
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Lead wires with a connector may be shipped with auto switches.
Dimensions (mm)
ø3.2 mounting hole
Indicator light
Most sensitive position
1472
Dimensions
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
23
81
127
D-F59 D-F5P D-J59 D-J5121
71
111
(mm)
Lead wire length
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
D-F59/D-F5P/D-J59 D-J51
2 cores (Brown/Blue)
Auto switch model D-F59 D-F5P D-J5
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto SwitchTie-rod Mounting StyleD-F59/D-F5P/D-J59/D-J51
D-F5, D-J5 (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F59
NPN
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less at
10 mA load current)
D-F5P
PNP
—
80 mA or less
0.8 V or less
D-J59
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less
at 24 VDC
D-J51
—
AC Relay, PLC
—
—
80 to 260 VAC
5 to 80 mA
14 V or less
1 mA or less at 100 VAC
1.5 mA or less at 200 VAC
RoHS
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
2-wire
Refer to SMC website for the details of the products conforming to the international standards.(Except D-J51)Auto Switch Specifications
PLC: Programmable Logic Controller
Weight (g)
Mounting hole
Indicator light
Most sensitive position
11
ø7
1.4
16
10
D-J51
Most sensitive position
33
ø4
4.5
12
1466
22
125
7Indicator light
1473
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight (g)
(mm)Dimensions
Auto switch model
0.5 m (Nil)1 m (M)
3 m (L)
5 m (Z)
D-M9NW(V)8
14
41
68
D-M9PW(V) D-M9BW(V)7
13
38
63
Lead wire length
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2-wire load current is reduced (2.5 to 40 mA).
Flexibility is 1.5 times greater than the conventional model (SMC comparison).
Using flexible cable as standard spec.
The proper operating range can be determined by the color of the light. (Red → Green ← Red)
D-M9W D-M9WV
RoHS
2 cores (Brown/Blue)
Auto switch model D-M9NW D-M9PW D-M9BW
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
2.7 x 3.2 (ellipse)
ø0.9
0.15
ø0.05
20
Oilproof Flexible Heavy-duty Lead Wire Specifications
2-Color Indication Type Solid State Auto SwitchDirect Mounting StyleD-M9NW(V)/D-M9PW(V)/D-M9BW(V)
PrecautionsCaution
Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-M9NWVD-M9NW D-M9BW D-M9BWV
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less
D-M9PWVD-M9PW
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
10 mA or less
40 mA or less
0.8 V or less at 10 mA (2 V or less at 40 mA)
100 µA or less at 24 VDC
CE marking, RoHS
In-line Perpendicular In-line Perpendicular In-line Perpendicular
NPN PNP
28 VDC or less —
D-M9W, D-M9WV (With indicator light)
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
M2.5 x 4 LSlotted set screw
Indicator light
2.7
22
2.6
4
2.8
3.2
6 Most sensitive position 4
2.6
9.5
M2.5 x 4 L
Indicator light
Slotted set screw
2.8
4.6
4
20
28
3.2
6 Most sensitive position
2.7
1474
Dimensions
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-Y7NW(V) D-Y7PW(V) D-Y7BW(V)
11
54
88
(g)
(mm)
Lead wire length
D-Y7W D-Y7WV
2 cores (Brown/Blue)
Auto switch model D-Y7NW D-Y7PW D-Y7BW
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.0
0.15
ø0.05
21
Oilproof Flexible Heavy-duty Lead Wire Specifications
RoHS
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
Using flexible cable as standard spec.
D-Y7W, D-Y7WV (With indicator light)Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-Y7NW
In-line
D-Y7NWV
Perpendicular
D-Y7BWV
Perpendicular
D-Y7PWV
Perpendicular
D-Y7BWD-Y7PW
In-line
1.5 V or less(0.8 V or less
at 10 mA load current)
CE marking, RoHS
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
In-line
PNP
—
80 mA or less
0.8 V or less
NPN
28 VDC or less
40 mA or less
5, 12, 24 VDC (4.5 to 28 VDC)
100 µA or less at 24 VDC
10 mA or less
IC circuit, Relay, PLC
3-wire
M2.5 x 4 LSlotted set screw
Indicator light
Most sensitive position
SM
C
6.2
5
2.5
29
ø3.
4
12.5
M2.5 x 4 LSlotted set screw
Indicator light
SM
C
27.3
6.2
5
12.5
8.5
2.5
ø3.4
Most sensitive position
2-Color Indication Type Solid State Auto SwitchDirect Mounting StyleD-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V)
1475
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight (g)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
57
92
11
50
81
D-H7NW D-H7PW D-H7BW
Lead wire length
Grommet
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-H7NW D-H7PW D-H7BW
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type Solid State Auto SwitchBand Mounting StyleD-H7NW/D-H7PW/D-H7BW
D-H7W (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-H7NW
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less(0.8 V or less
at 10 mA load current)
100 µA or less at 24 VDC
D-H7BW
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-H7PW
PNP
—
80 mA or less
0.8 V or less
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
4.6
29
9
4.3
10.5Most sensitive position
6.58
811.5
Indicator light
ø3.
4
ø3.5 mounting hole
1476
Weight (g)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
20
78
124
18
68
108
D-G59W D-G5PW D-K59W
Lead wire length
Grommet
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-G59W D-G5PW D-K59W
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type Solid State Auto SwitchBand Mounting StyleD-G59W/D-G5PW/D-K59W
D-G5W, D-K59W (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-G59W
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
100 µA or less at 24 VDC
D-K59W
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-G5PW
PNP
—
80 mA or less
0.8 V or less1.5 V or less(0.8 V or less
at 10 mA load current)
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
Indicator light
ø4.5 mounting hole
Most sensitive position
1477
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight (g)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
57
92
11
50
81
D-F79W D-F7PW D-J79W
Lead wire length
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-F79W D-F7PW D-J79W
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type Solid State Auto SwitchRail Mounting StyleD-F79W/D-F7PW/D-J79W
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
D-F7W, D-J79W (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F79W
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
100 µA or less at 24 VDC
D-J79W
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F7PW
PNP
—
80 mA or less
0.8 V or less1.5 V or less(0.8 V or less
at 10 mA load current)
CE marking, RoHS
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Indicator light
ø3.2 mounting hole
8
23
4.6
15
7
Most sensitive position8.5
11
6.2
3.2
ø3.
4
Dimensions (mm)
1478
Weight (g)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
57
92
11
50
81
D-F7NWV D-F7BWV
GrommetElectrical entry: Perpendicular
RoHS
2-Color Indication Type Solid State Auto SwitchRail Mounting StyleD-F7NWV/D-F7BWV
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-F7NWV D-F7BWV
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
D-F7WV (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F7BWV
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F7NWV
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
100 µA or less at 24 VDC
1.5 V or less(0.8 V or less
at 10 mA load current)
CE marking, RoHS
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
ø3.2 mounting hole
Indicator light
Most sensitive position
Lead wire length
1479
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Dimensions (mm)
Mounting hole
Indicator light
Most sensitive position
Weight (g)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
23
81
127
21
71
111
D-F59W D-F5PW D-J59W
Lead wire length
Grommet
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
2 cores (Brown/Blue)
Auto switch model D-F59W D-F5PW D-J59W
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type Solid State Auto SwitchTie-rod Mounting StyleD-F59W/D-F5PW/D-J59W
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
D-F5W, D-J59W (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F59W
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
100 µA or less at 24 VDC
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
D-J59W
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F5PW
PNP
—
80 mA or less
0.8 V or less1.5 V or less(0.8 V or less
at 10 mA load current)
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
CE marking, RoHS
1480
ø3.
4
Indicator light
ø3.5 mounting hole
Most sensitive position
Dimensions
Grommet
Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
(mm)
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
56
90
D-H7NF
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-H7NFSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
4 cores (Brown/Blue/Black/Orange)
ø0.98
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type with Diagnostic OutputSolid State Auto Switch: Band Mounting StyleD-H7NF
D-H7NF (With indicator light)Auto switch model
Wiring type
Output type
Diagnostic output
Applicable load
Power voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Current leakage
Indicator light
Standard
D-H7NF
4-wire
NPN
Normal operation
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
50 mA or less at the total amount of normal output and diagnostic output
1.5 V or less (0.8 V or less at each output 5 mA)
100 µA or less at 24 VDC
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Diagnostic Output Operation
Indicator light
OUT(Normal output)
Diagnosis OUT(Diagnostic output)
OFF OFF
ON
Red Green Red Red
The diagnostic output signal is output within the red display area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the proper operating range (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON.
1481
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
ø4.5 mounting hole
Most sensitive position
Dimensions
Grommet
Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
(mm)
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
20
74
117
D-G59F
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-G59FSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
4 cores (Brown/Blue/Black/Orange)
ø1.29
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type with Diagnostic OutputSolid State Auto Switch: Band Mounting StyleD-G59F
D-G59F (With indicator light)Auto switch model
Wiring type
Output type
Diagnostic output
Applicable load
Power voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Current leakage
Indicator light
Standard
D-G59F
4-wire
NPN
Normal operation
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
50 mA or less at the total amount of normal output and diagnostic output
1.5 V or less (0.8 V or less at 5 mA)
100 µA or less at 24 VDC
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
ø4
Indicator light
Diagnostic Output OperationThe diagnostic output signal is output within the red display area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the proper operating range (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON.
Indicator light
OUT(Normal output)
Diagnosis OUT(Diagnostic output)
OFF OFF
ON
Red Green Red Red
1482
The diagnostic output signal is output within the red display area (where indicator light is Red), and it is not output within the proper operating range (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated.
Indicator light
OUT(Normal output)
Diagnosis OUT(Diagnostic output)
Red Green Red Red
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
13
56
90
D-F79F
(g)
Grommet
Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-F79FSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
4 cores (Brown/Blue/Black/Orange)
ø0.98
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Auto Switch Specifications
D-F79F (With indicator light)Auto switch model
Wiring type
Output type
Diagnostic output
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F79F
4-wire
NPN
Normal operation
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
50 mA or less at the total amount of normal output and diagnostic output
1.5 V or less (0.8 V or less at 5 mA)
100 µA or less at 24 VDC
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Dimensions (mm)
ø3.2 Mounting hole
ø3.
4
Most sensitive position
Indicator light
Diagnostic Output Operation
2-Color Indication Type with Diagnostic OutputSolid State Auto Switch: Rail Mounting StyleD-F79F
1483
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
ø4
Indicator light
Mounting hole
Most sensitive position
Dimensions
Grommet
(mm)
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
D-F59F22
77
121
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-F59FSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
4 cores (Brown/Blue/Black/Orange)
ø1.29
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
2-Color Indication Type with Diagnostic OutputSolid State Auto Switch: Tie-rod Mounting StyleD-F59F
Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
Auto Switch Specifications
D-F59F (With indicator light)Auto switch model
Wiring type
Output type
Diagnostic output
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F59F
4-wire
NPN
Normal operation
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
50 mA or less at the total amount of normal output and diagnostic output
1.5 V or less (0.8 V or less at 5 mA)
100 µA or less at 28 VDC
Standard CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Diagnostic Output Operation
The diagnostic output signal is output within the red display area (where indicator light is Red), and it is not output within the proper operating range (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated.
Indicator light
OUT(Normal output)
Diagnosis OUT(Diagnostic output)
Red GreenOFF OFFRed RedON
1484
Weight (g)
Auto switch model
0.5 m (Nil)1 m (M)
3 m (L)
5 m (Z)
D-M9NA(V)8
14
41
68
D-M9PA(V) D-M9BA(V)7
13
38
63
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
DimensionsD-M9A D-M9AV
(mm)
Grommet
Water (coolant) resistant type 2-wire load current is reduced
(2.5 to 40 mA). The proper operating range can
be determined by the color of the light. (Red → Green ← Red)
Using flexible cable as standard spec.
RoHS
2 cores (Brown/Blue)
Auto switch model D-M9NA D-M9PA D-M9BA
3 cores (Brown/Blue/Black)
Sheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
2.7 x 3.2 (ellipse)
ø0.9
0.15
ø0.05
20
Oilproof Flexible Heavy-duty Lead Wire Specifications
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Direct Mounting StyleD-M9NA(V)/D-M9PA(V)/D-M9BA(V)
PrecautionsCaution
Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.Please consult with SMC if using coolantliquid other than water based solution.
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-M9NAVD-M9NA D-M9BA D-M9BAV
2-wire
—
24 VDC relay, PLC
—
—
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less
D-M9PAVD-M9PA
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
10 mA or less
40 mA or less
0.8 V or less at 10 mA (2 V or less at 40 mA)
100 µA or less at 24 VDC
In-line Perpendicular In-line Perpendicular In-line Perpendicular
NPN PNP
CE marking, RoHS
28 VDC or less —
D-M9A, D-M9AV (With indicator light)
Auto Switch SpecificationsPLC: Programmable Logic Controller
4
0.2
3
SMC4
2.8
24 2.7
Indicator light
M2.5 x 4 L
Slotted set screw
6
3.2
Most sensitive position
2.7
6
2.6
9.3
Most sensitive position
4
SMC
22
3.2
4.6
2.8
4
28
M2.5 x 4 L
Slotted set screwIndicator light
1485
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Dimensions
Grommet
Water (coolant) resistant type Using flexible cable as
standard spec. The proper operating range
can be determined by the color of the light. (Red → Green ← Red)
Weight
Auto switch model
3 m (L)
5 m (Z)
D-Y7BA54
88
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
(mm)
Auto switch model D-Y7BASheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
2 cores (Brown/Blue)
ø1
0.15
ø0.05
21
Oilproof Flexible Heavy-duty Lead Wire Specifications
RoHS
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Direct Mounting StyleD-Y7BA
Caution
Please consult with SMC if using coolant liquid other than water based solution.Detection characteristics (operating range) are the same as D-Y5 and D-Y7W, but the detection area length is different.
Precautions
Auto Switch Specifications
D-Y7BA (With indicator light)Auto switch model
Wiring type
Applicable load
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-Y7BA
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
5
12.5 Most sensitive position
Production lot
DC24V 5.2
2.5
6.2
35
Indicator light
M2.5 x 4 L
D−Y7BA
SM
C
Slotted set screw
1486
Dimensions
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Weight
Auto switch model
3 m (L)
5 m (Z)
(g)
(mm)
Lead wire length
D-H7BA50
81
Auto switch model D-H7BASheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
2 cores (Brown/Blue)
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Band Mounting StyleD-H7BA
Grommet
Water (coolant) resistant type The proper operating range
can be determined by the color of the light.(Red → Green ← Red)
PrecautionsCaution
Please consult with SMC if using coolant liquid other than water based solution.
D-H7BA (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-H7BA
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Standard CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
ø3.
4
ø3.5 mounting hole
Most sensitive position
Indicator light
1487
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
3 m (L)
5 m (Z)
D-G5BA68
108
(g)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-G5BASheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
2 cores (Brown/Blue)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Band Mounting StyleD-G5BA
Grommet
Water (coolant) resistant type The proper operating range
can be determined by the color of the light.(Red → Green ← Red)
PrecautionsCaution
Please consult with SMC if using coolant liquid other than water based solution.
D-G5BA (With indicator light)Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-G5BA
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Standard CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
ø4
ø4.5 mounting hole
Most sensitive position
Indicator light
1488
8.5
15
6.2
3.2
11
23
SM
C
8
7
15
ø3.4
ø3.2 mounting hole
Most sensitive position
Indicator lightIndicator light
ø3.2 mounting hole
Most sensitive position
Dimensions
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Weight
Auto switch model
3 m (L)
5 m (Z)
D-F7BA50
81
D-F7BAV
(g)
(mm)
Lead wire length
D-F7BA D-F7BAV
Auto switch model D-F7BASheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
2 cores (Brown/Blue)
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Rail Mounting StyleD-F7BA(V)
Grommet
Water (coolant) resistant type The proper operating range
can be determined by the color of the light. (Red → Green ← Red)
PrecautionsCaution
Please consult with SMC if using coolant liquid other than water based solution.
Auto Switch Specifications
D-F7BA(V) (With indicator light)Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F7BAV
Perpendicular
D-F7BA
In-line
Standard CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
1489
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Weight
Auto switch model
3 m (L)
5 m (Z)
(g)
(mm)
Lead wire length
D-F5BA71
111
Dimensions
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-F5BASheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
2 cores (Brown/Blue)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Water Resistant 2-Color Indication TypeSolid State Auto Switch: Tie-rod Mounting StyleD-F5BA
Grommet
Water (coolant) resistant type The proper operating range
can be determined by the color of the light. (Red → Green ← Red)
Caution
Please consult with SMC if using coolant liquid other than water based solution.
Precautions
Auto Switch Specifications
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F5BA
2-wire
—
24 VDC Relay, PLC
—
—
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F5BA (With indicator light)
Standard CE marking, RoHS
Refer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
ø4
Mounting hole
Most sensitive position
Indicator light
1490
ø4.5 mounting hole
Most sensitive position
ø4
Indicator light
Dimensions
Weight
Auto switch model
3 m (L)
5 m (Z)
D-G5NT78
124
(g)
(mm)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-G5NTSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
3 cores (Brown/Blue/Black)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto Switch with TimerBand Mounting StyleD-G5NT
Grommet
With built-in OFF-delay timer (approx. 200 ms)
Easy intermediate detection
D-G5NT (With indicator light)Auto switch model
Wiring type
Output type
Output operation
Operating time
Off-delay time
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-G5NT3-wire
NPN
Off-delay
1 ms or less
200 ± 50 ms
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less (0.8 V or less at 10 mA)
100 µA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Timer Operation
Detection of intermediate positioning for high-speed cylinderDetecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning.
Ex.) Cylinder speed — 1000 mm/sec.PLC response time — 0.1 sec.Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into consider-ation when using.
Auto switch detecting time
Auto switch output ON time
PLC response time
Auto switch operating range (mm)Cylinder speed (mm/s)
1491
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
ø3.2 mounting hole
Indicator light
Dimensions
Weight
Auto switch model
3 m (L)
5 m (Z)
D-F7NT57
92
(g)
(mm)
Lead wire length
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Auto switch model D-F7NTSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø3.4
3 cores (Brown/Blue/Black)
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto Switch with TimerRail Mounting StyleD-F7NT
Grommet
With built-in OFF-delay timer (approx. 200 ms)
Easy intermediate detection
D-F7NT (With indicator light)Auto switch model
Wiring type
Output type
Output operation
Operating time
Off-delay time
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F7NT3-wire
NPN
Off-delay
1 ms or less
200 ± 50 ms
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less (0.8 V or less at 10 mA)
100 µA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
Timer Operation
Detection of intermediate positioning for high-speed cylinderDetecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning.
Ex.) Cylinder speed — 1000 mm/sec.PLC response time — 0.1 sec.Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into consider-ation when using.
Switch detecting time
Switch output ON time
PLC response time
Switch operating range (mm)Cylinder speed (mm/s)
ø3.
4
Most sensitive position
1492
Dimensions
Timer Operation
Note 1) Refer to page 1456 for solid state auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.
Weight
Auto switch model
3 m (L)
5 m (Z)
(g)
(mm)
Lead wire length
D-F5NT81
127
Auto switch model D-F5NTSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
Minimum bending radius [mm] (Reference values)
ø4
3 cores (Brown/Blue/Black)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
RoHS
Solid State Auto Switch with TimerTie-rod Mounting StyleD-F5NT
Grommet
With built-in OFF-delay timer (approx. 200 ms)
Easy intermediate detection
Detection of intermediate positioning for high-speed cylinderDetecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning.
Ex.) Cylinder speed — 1000 mm/sec.PLC response time — 0.1 sec.Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into consider-ation when using.
Switch detecting time
Switch output ON time
PLC response time
Switch operating range (mm)Cylinder speed (mm/s)
D-F5NT (With indicator light)Auto switch model
Wiring type
Output type
Output operation
Operating time
Off-delay time
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Standard
D-F5NT3-wire
NPN
Off-delay
1 ms or less
200 ± 50 ms
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less (0.8 V or less at 10 mA)
100 µA or less at 24 VDC
Red LED illuminates when turned ON.
CE marking, RoHS
Auto Switch SpecificationsRefer to SMC website for the details of the products conforming to the international standards.
PLC: Programmable Logic Controller
ø4
Indicator light
Mounting hole
Most sensitive position
1493
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Made to Order Specifications: Solid State Auto Switch
Refer to SMC website for the details of the products conforming to the international standards.
• Eliminates the harnessing work by cable with connector specifications
• Adopts global standardized connector (IEC947-5-2)
• IP67 construction
With Pre-wired Connector1
How to Order
Cable length0.5 m1.0 m3.0 m
SML
Connector model
D M9N S A PC
Note) L is available for the D-P4DW type only.
ABD
Note) Type D is available for the D-P4DW type only.
M8-3 pinM8-4 pinM12-4 pin
Connector Specifications
12
1 2
43
Connector model
Pin arrangement
M8-3 pin M8-4 pin M12-4 pin
1
3
4
3 4
Solid state auto switchStandard part no.
∗ For the applicable auto switch model, refer to the table below.
Applicable Auto Switch
Grommet (In-line)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.0
Lead wire length (m)
1.00.5Applicable modelFunctionMounting
F79, F7P, J79F7NV, F7PV, F7BVF79W, F7PW, J79W
F7NWV, F7BWVF79FF7BA
F7BAVF7NTP4DW
H7A1, H7A2, H7BG59, G5P, K59
H7NW, H7PW, H7BWG59W, G5PW, K59W
H7NF, G59FH7BA, G5BA
G5NTG5NB
F59, F5P, J59F59W, F5PW, J59W
F59FF5BAF5NT
Electrical entry
Grommet (In-line)Grommet
(Perpendicular)
Grommet (In-line)Grommet
(Perpendicular)
Grommet (In-line)
Grommet (Perpendicular)
—
2-colorindication
With diagnostic output
Water resistant
With timer
Magnetic field resistant
—
2-colorindication
Diagnostic output
Water resistant
With timer
Wide detection
—
2-color indication
Diagnostic output
Water resistant
With timer
Rail mounting style
Band mounting style
Tie-rod mounting style
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.01.00.5
Y59A, Y7P, Y59B
Y69A, Y7PV, Y69B
M9N, M9P, M9B
M9NV, M9PV, M9BV
F8N, F8P, F8B
F6N, F6P, F6B
Y7G, Y7H
F9G, F9H
Y7NW, Y7PW, Y7BW
Y7NWV, Y7PWV, Y7BWV
M9NW, M9PW, M9BW
M9NWV, M9PWV, M9BWV
Y7BA
M9NA, M9PA, M9BA
M9NAV, M9PAV, M9BAV
S791/2, S7P1/2, T791/2
S991/2, S9P1/2, T991/2
S99V1/2, T99V1/2
Grommet (In-line)Grommet
(Perpendicular)
Grommet (In-line)
Grommet (Perpendicular)
Grommet (In-line)
Grommet (In-line)
Grommet (In-line)Grommet
(Perpendicular)
Grommet (In-line)Grommet
(Perpendicular)
Grommet (In-line)
Grommet (Perpendicular)
Grommet (In-line)
Grommet (Perpendicular)
—
—
2-colorindication
Normally closed
Water resistant
Direct mounting style
Rotaryactuator
Lead wire length (m)Applicable modelFunctionMounting
Electrical entry
1494
M8-4 pin
M12-4 pin
M8-3 pin
12
3 4
1 4
3
1 2
43
Connector Pin Arrangement
Sensor type
DC 2-wire type
DC 2-wire, Non-polar type
DC 3-wire type
DC 4-wire type
Brown
—
Brown
Brown
1 pin 2 pin 3 pin 4 pin
Color distinction of lead wire Meaning of contact number
1 pin 2 pin 3 pin 4 pin
Connector SpecificationsConnector model
Pin arrangement
Conformed standard
Impact resistance
Enclosure
Insulation resistance
Withstand voltage
JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
300 m/s2
IP67 (IEC60529 standard)
100 MΩ or more at 500 VDC measured via megohmmeter
1500 VAC 1 minute (between contacts), Leak current 1 mA or less
M8-3 pin M8-4 pin M12-4 pin
—
—
—
Orange
—
Brown
Blue
Blue
Blue
Blue
Black
Black
OUT (+)
—
DC (+)
DC (+)
—
—
—Diagnostic
output
—
OUT (±)
DC (–)
DC (–)
ø14
44
ø10
31.4
Dimensions
Connector model
M8-3 pin 4 pin
M12-4 pin
Sensor section
Sensor section
Weight for Connector Type Connection (Female side) Connector CableAs the parts are not supplied from SMC, refer to the application examples listed in the below.(For detail such as catalog availability, etc., please contact each manufacturer.)
Connector size
M8
M12
SAC-3P
M8-3D
M8-4D
XS3
SAC-4P
VA-4D
XS2
PA5-4I
HR24
CM01-8DP4S
Manufacturer
Phoenix Contact
Corrence Corporation
OMROM Corporation
Phoenix Contact
Corrence Corporation
OMROM Corporation
Azbil Corp.
Hirose Electric Co., Ltd.
DDK Ltd.
4
3
Number of pins Applicable series example
Part no. Connector type
M8-3 pin
M8-4 pin
M12-4 pin
4 g
4 g
About 11 g
Weight
D-APC
D-BPC
D-DPC
OUT (–)
OUT ( )
OUT
OUT
±
With Pre-wired Connector
1495
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
Made to Order Specifications: Solid State Auto Switch-50: Without Indicator Light (Dark room) Specifications-61: Oilproof Flexible Heavy-duty Cord Specifications
-50Without Indicator Light (for dark room specifications)
Possible to use under the environment which hates a light.
50D
Solid state auto switch model
Lead wire lengthFor lead wire length, refer to page 1456.
Without indicator light(for dark room specifications)
2Symbol
Applicable part no.: General purpose type, solid state auto switch except D-J51
Note) Please consult with SMC for water resistant type, timer equipped type, diagnostic output type, wide range detection type, magnetic field resistant type, heat resistant type.
61D
Dimensions and specifications are common as standard products with the exception of no indicator light.
Oilproof Flexible Heavy-duty Cord Specifications3Symbol
-61
This is the product which uses a heavy-duty cord having flexible characteristics 5 times (SMC comparison) as strong as oilproof heavy-duty cord used in the standard products.
Lead wire lengthFor lead wire length, refer to page 1456.
Oilproof flexible heavy-duty cord specifications
Solid state auto switch part no.
Applicable part no: All the solid state auto switches with the exceptance of D-J51, diagnostic output type, terminal conduit type, connector type, magnetic field resistant type, heat resistant type
Oilproof flexible heavy-duty cord is used for D-Y59 , Y69 , Y7P(V), D-M9, M9V, D-M9W, M9WV, M9A, M9AV as standard. No need to suffix -61 to the end of part number.
Note)
AB
AB
Specifications are the same as standard products with the exception of lead wire specifications.Lead wire: For D-F8 type············ ø2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)For other model nos.··················· ø3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type. Lead wire diameter is changed from ø4 to ø3.4. In other series products, it is common as standard product's specifications.
1496
Type Function Electrical entry Auto switch model PageAuto switch
mounting style
Ree
d A
uto
Sw
itch
Gen
eral
pu
rpo
se
Band
Rail
Tie-rod
Grommet
Connector
Terminal conduit
DIN terminal
Grommet
Connector
Grommet
Band
Rail
Tie-rod
Grommet
Grommet
Grommet
D-B59W
D-A79W
D-A59W
1508
1509
15102-colo
rind
icatio
n
D-C73/C76/C80
D-B53/B54/B64
D-C73C/C80C
D-A33/A34
D-A44
D-A72/A73/A80
D-A72H/A73H/A76H/A80H
D-A73C/A80C
D-A53/A54/A56/A64/A67
∗ Auto switches with an asterisk (∗) can be mounted on a band (excluding D-A9V), rail, tie-rod or square groove with an auto switch mounting bracket. For details, refer to “How to Mount and Move the Auto Switch” of each series.
∗∗ This auto switch can be mounted by tie-rod with using auto switch mounting bracket. For details, refer to “How to Mount and Move the Auto Switch” of each series.
Grommet
D-A90/A93/A96∗ D-A90V/A93V/A96V∗
D-Z73/Z76/Z80∗∗
Direct1498
1507
Reed Switch Variations
Reed Auto SwitchesGeneral Purpose Type,2-Color Indication Type
1499
1500
1501
1502
1502
1503
1504
1505
1506
1497
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
ø2.
72
24.5(22)
2.8 4.5
4
10 ( ): dimensions for D-A96.
D-A90 without indicator light
Indicator light
4
9.1
5.1
ø2.7
10
4.5
Most sensitive position
2
22
6
D-A90V without indicator light
Indicator lightMost sensitive position
Auto switch modelSheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
Lead wire minimum bending radius [mm] (Reference values)
Grommet D-A90, D-A90V (Without indicator light) Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ Contact protection circuit Internal resistance Standard
D-A93, D-A93V, D-A96, D-A96V (With indicator light) Auto switch model Applicable load Load voltage Load current range and Maximum load current (3)
Circuit diagram∗ Contact protection circuit Internal voltage drop
Indicator light Standard
D-A90, D-A90VIC circuit, Relay, PLC
r
None1 Ω or less (Including lead wire length of 3 m)
CE marking
D-A93, D-A93VRelay, PLC
e
24 VDC(4)
5 to 40 mA
NoneD-A93: 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)D-A93V: 2.7 V or less
Red LED illuminates when turned ON.CE marking
100 VAC
5 to 20 mA
D-A96, D-A96VIC circuit
4 to 8 VDC
t
20 mA
0.8 V or less
Model D-A90630—
D-A90V630—
D-A936
3047
D-A93V6
3047
D-A96841—
D-A96V8
41—
Weight
D-A90/D-A93/D-A96 D-A90V/D-A93V/D-A96V
Lead wire length0.5 m (Nil)
3 m (L)5 m (Z)
Slotted set screwM2.5 x 4 L
Slotted set screw
M2.5 x 4 L
∗ Refer to the circuit diagram no. on page 1459. Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Dimensions (mm)
3 cores (Brown/Blue/Black)ø0.910.15
D-A90(V) D-A93(V) D-A96(V)
2 cores (Brown/Blue)ø0.960.18
ø2.7
ø0.0817
Oilproof Heavy-duty Lead Wire Specifications
Refer to SMC website for the details of the products conforming to the international standards.
Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.
PrecautionsCaution
Auto Switch SpecificationsPLC: Programmable Logic Controller
24 V or less50 mA
48 V or less40 mA
100 V or less20 mA
ACDC
ACDC
ACDC
Reed Auto SwitchDirect Mounting StyleD-A90(V)/D-A93(V)/D-A96(V)
(g)
1498
4.3
ø3.
4
6.58
2
9
26
Indicator lightD-C80 without indicator light
SM
C
9.5
811.5
Most sensitive position
ø3.5
Weight
Auto switch model0.5 m (Nil)
3 m (L)5 m (Z)
94676
1050—
946—
D-C73 D-C76 D-C80
(g)
Grommet PLC: Programmable Logic Controller
D-C7 (With indicator light)
Applicable loadLoad voltageMax. load current and range (3)
Circuit diagram∗Contact protection circuitInternal voltage dropIndicator lightStandard
D-C8 (Without indicator light)
Applicable loadLoad voltageMax. load currentCircuit diagram∗Contact protection circuitInternal resistanceStandard
D-C73Relay, PLC
e
24 VDC(4)
5 to 40 mA100 VAC
5 to 20 mA
None2.4 V or less
Red LED illuminates when turned ON.CE marking
D-C76IC circuit
4 to 8 VDC20 mAt
0.8 V or less
D-C80Relay, PLC, IC circuit
r
None1 Ω or less (Including lead wire length of 3 m)
CE marking
Lead wire length
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
2 cores (Brown/Blue)
Auto switch model D-C73 D-C76 D-C80
2 cores (Brown/Blue)Sheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
ø3.43 cores (Brown/Blue/Black)
ø1.10.2
ø0.0821
Oilproof Heavy-duty Lead Wire Specifications
Lead wire minimum bending radius [mm] (Reference values)
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
Dimensions (mm)
24 V or less50 mA
48 V 40 mA
100 V 20 mA
ACDC
ACDC
ACDC
Reed Auto SwitchBand Mounting StyleD-C73/D-C76/D-C80
Auto switch model
Auto switch model
1499
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
6.5
ø4
33
13
15 12 SMC
14.3
9.5
15.5
6.5
ø4.5
D-B53PLC
24 VDC(4)
5 to 50 mAe
None2.4 V or less
Red LED illuminates when turned ON.CE marking
D-B54Relay, PLC
24 VDC(4)
5 to 50 mA100 VAC
5 to 25 mA200 VAC
5 to 12.5 mAq
Built-in2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA)
D-B64Relay, PLC
w
Built-in25 Ω or lessCE marking
Weight
Auto switch model0.5 m (Nil)
3 m (L)5 m (Z)
2278
126
2278126
2278—
D-B53 D-B54 D-B64
(g)
Lead wire length
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Auto switch model
Auto switch model
Auto switch model
D-B53/B54/B64Sheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
ø42 cores (Brown/Blue)
ø1.220.3
ø0.0824
Oilproof Heavy-duty Lead Wire Specifications
Lead wire minimum bending radius [mm] (Reference values)
Grommet
Reed Auto SwitchBand Mounting StyleD-B53/D-B54/D-B64
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
PLC: Programmable Logic Controller
D-B5 (With indicator light)
Applicable loadLoad voltageLoad current range (3)
Circuit diagram∗Contact protection circuitInternal voltage drop Indicator lightStandard
D-B6 (Without indicator light)
Applicable loadLoad voltageMax. load current Circuit diagram∗Contact protection circuitInternal resistanceStandard
100 VACMax. 25 mA
200 VACMax. 12.5 mA
ACDC24 V or less
Max. 50 mA
Dimensions (mm)
Indicator lightD-B64 without indicator light
Most sensitiveposition
1500
Weight
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
14
53
83
14
53
83
D-C73C D-C80C
(g)
Reed Auto SwitchBand Mounting StyleD-C73C/D-C80C
Lead wire length
D-C73C (With indicator light)Auto switch model
Applicable load
Load voltage
Load current range (4)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
Standard
D-C73C
Relay, PLC
24 VDC (5)
5 to 40 mA
e
None
2.4 V or less
Red LED illuminates when turned ON.
CE marking
D-C80C (Without indicator light)Auto switch model
Applicable load
Load voltage
Maximum load current
Circuit diagram∗
Contact protection circuit
Internal resistance
Standard
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Lead wire with connector may be shipped with switch.Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 5) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
Lead wires with a connector indication
Refer to SMC website for the details of the products conforming to the international standards.
Connector PLC: Programmable Logic Controller
Auto Switch Specifications
D-C80C
Relay, PLC
24 V or less
50 mA
r
None
1 Ω or less (Including lead wire length of 3 m)
CE marking
ACDC1. Confirm that the connector is appropriately
tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. For details, refer to Best Pneumatics No.2.
PrecautionsCaution
Dimensions (mm)
Indicator lightD-C80C without indicator light
Most sensitive position
Lead wire with connector
Part No. of Lead Wires with Connectors(Applicable only for connector type)
1501
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
D-A3 D-A44
Weight
Auto switch model
114116
D-A33116
D-A34 D-A44
(g)
Lead wire None
46
16
25.7
58.7
6.5
349.5
36
34 27.5
Most sensitive position
Terminal conduit: D-A3DIN terminal: D-A4
1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance.
2. After wiring, confirm that tightening gland and all screws are tightened.
PrecautionsCaution
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
D-A3 (With indicator light) Terminal conduitAuto switch model
Applicable load
Load voltage
Load current range (2)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
Standard
D-A33
PLC
24 VDC (3)
5 to 50 mA
e
None
2.4 V or less
24 VDC (3)
5 to 50 mA
D-A34
Relay, PLC
100 VAC
5 to 25 mA
q
Built-in
2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA)
200 VAC
5 to 12.5 mA
Red LED illuminates when turned ON.
CE marking
D-A44 (With indicator light) DIN terminalAuto switch model
Applicable load
Load voltage
Load current range
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
Standard
24 VDC (3)
5 to 50 mA
D-A44
Relay, PLC
100 VAC
5 to 25 mA
q
Built-in
2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA)
Red LED illuminates when turned ON.
CE marking
200 VAC
5 to 12.5 mA
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 3) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Dimensions (mm)
G 1/2Applicable cable O.D. ø6.8 to ø11.5
Tightening gland
Indicator light Most sensitive position
Applicable cable O.D. ø6.8 to ø9.6G 1/2
Tightening gland
Reed Auto SwitchBand Mounting StyleD-A33/D-A34/D-A44
1502
( ) values for D-A72
8
15 (
14)
7 (6
)4
23 (22)
Indicator light
D-A80 without indicator light
ø3.2
9 (8.5)
ø3.4
Most sensitive position
6 (6
.2)
3
11.5
(11
.7)
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
10
47
—
10
47
77
10
47
—
D-A72 D-A73 D-A80
Lead wire length
D-A7 (With indicator light)Auto switch model
Applicable loadLoad voltageLoad current range (3)
Circuit diagram∗Contact protection circuitInternal voltage dropIndicator lightStandard
24 VDC (4)
5 to 40 mAe
None2.4 V or less
Red LED illuminates when turned ON.CE marking
100 VAC5 to 20 mA
D-A72Relay, PLC
200 VAC5 to 10 mA
D-A73Relay, PLC
D-A80Relay, IC circuit, PLC
40 mAr
None1 Ω or less (Including lead wire length of 3 m)
CE marking
D-A8 (Without indicator light)Auto switch model
Applicable loadLoad voltageMaximum load currentCircuit diagram∗Contact protection circuitInternal resistanceStandard
50 mA 20 mA
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Auto switch model D-A72 D-A73 D-A80Sheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
ø3.42 cores (Brown/Blue)
ø1.10.2
ø0.0821
Oilproof Heavy-duty Lead Wire Specifications
Lead wire minimum bending radius [mm] (Reference values)
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
GrommetElectrical entry: Perpendicular
Dimensions (mm)
Weight (g)
24 V or lessACDC 48 V AC
DC 100 V ACDC
Reed Auto SwitchRail Mounting StyleD-A72/D-A73/D-A80
1503
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
2
ø3.
4
22
8.5
15
74
8
ø3.2
SMC
6.2
3.3
10.2
Auto switch model0.5 m (Nil)
3 m (L)5 m (Z)
1047—
1047—
1152—
104777
D-A72H D-A73H D-A76H D-A80H
Lead wire length
D-A7H (With indicator light)Auto switch model
Applicable loadLoad voltageMax. load current/Load current range(3)
Circuit diagram∗Contact protection circuitInternal voltage dropIndicator lightStandard
100 VAC5 to 20 mA
D-A72HRelay, PLC
200 VAC5 to 10 mA
D-A73HRelay, PLC
None
Red LED illuminates when turned ON.CE marking
e
D-A80HRelay, IC circuit, PLC
40 mAr
None1 Ω or less (Including lead wire length of 3 m)
CE marking
D-A80H (Without indicator light)Auto switch model
Applicable loadLoad voltageMaximum load currentCircuit diagram∗Contact protection circuitInternal resistanceStandard
20mA50 mA
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
2 cores (Brown/Blue)
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-A72H/A73H D-A76H D-A80H
2 cores (Brown/Blue)Sheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
ø3.43 cores (Brown/Blue/Black)
ø1.10.2
ø0.0821
Oilproof Heavy-duty Lead Wire Specifications
24 VDC (4)
5 to 40 mAe
2.4 V or less
D-A76HIC circuit
4 to 8 VDC20 mAt
0.8 V or less
GrommetElectrical entry: In-line
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
24 V or lessACDC 48 V AC
DC 100 V ACDC
Weight (g)
DimensionsD-A7H, D-A80H
(mm)
Indicator lightD-A80H without indicator light
Most sensitive position
Reed Auto SwitchRail Mounting StyleD-A7H/D-A80H
1504
Auto switch model
0.5 m (Nil)
3 m (L)
5 m (Z)
12
54
84
12
54
84
D-A73C D-A80C
Lead wire length
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Lead wire with connector may be shipped with the auto switch.Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 5) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
Part No. of Lead Wires with Connectors(Applicable only for connector type)
Connector
1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. Refer to Best Pneumatics No.2 for the details.
PrecautionsCaution
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
D-A73C (With indicator light)D-A73C
Relay, PLC
24 VDC (5)
5 to 40 mA
e
None
2.4 V or less
Red LED illuminates when turned ON.
CE marking
D-A80C
Relay, IC circuit, PLC
50 mA
r
None
1 Ω or less (Including lead wire length of 3 m)
CE marking
D-A80C (Without indicator light)
Auto switch model
Applicable load
Load voltage
Load current range (4)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
Standard
Auto switch model
Applicable load
Load voltage
Maximum load current
Circuit diagram∗
Contact protection circuit
Internal resistance
Standard
24 V ACDC
Dimensions (mm)
Weight (g)
Indicator lightD-A80C without indicator light
Most sensitive position
Lead wire with connector
Lead wires with a connector indication
Reed Auto SwitchRail Mounting StyleD-A73C/D-A80C
1505
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
1233
22
512
4.5
6 14
6
D-A64/A67 without indicator light
Indicator light
ø4
16 Most sensitive position
1611
Auto switch model0.5 m (Nil)
3 m (L)5 m (Z)
244896
2448—
2448—
D-A53 D-A54 D-A56 D-A64 D-A67
Lead wire length
D-A5 (With indicator light)Auto switch model
Applicable loadLoad voltageMaximum load (3)
current and rangeCircuit diagram∗Contact protection circuitInternal voltage dropIndicator lightStandard
D-A53
24 VDC (4)
5 to 50 mA
D-A54
200 VAC
5 to 12.5 mA
D-A56PLC
24 VDC (4)
5 to 50 mA
e
None2.4 V or less
Relay, PLC100 VAC
5 to 25 mA
q
Built-in2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA)
IC circuit4 to 8 VDC
20 mA
t
None0.8 V or less
D-A6 (Without indicator light)Auto switch model
Applicable loadLoad voltageMaximum load currentCircuit diagram∗Contact protection circuit
Internal resistance
D-A67PLC/IC circuitMax. 24 VDC
30 mAr
None1 Ω or less (Including
lead wire length of 3 m)
D-A64Relay, PLC100 VAC25 mAw
Built-in
25 Ω or less
Red LED illuminates when turned ON.CE marking
Standard CE marking
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will
not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
2 cores (Brown/Blue)
0.3
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-A53/A54 D-A56 D-A64/A67Sheath
Insulator
Conductor
Outside diameter [mm]Number of cores
Outside diameter [mm]Effective area [mm2]
Strand diameter [mm]
ø43 cores (Brown/Blue/Black)
ø1.220.2
ø0.0824
2 cores (Brown/Blue)
0.3
Oilproof Heavy-duty Lead Wire Specifications
Grommet PLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
200 VAC12.5 mA50 mA
24 V or lessACDC
Dimensions (mm)
Weight (g)
Reed Auto SwitchTie-rod Mounting StyleD-A5/D-A6
1506
12.5 ø2.
7
5.5
30.52.3
6.2
1.5
2.5
6.2
27.6
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 1241.
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-Z73 D-Z76 D-Z80ø2.7
2 cores (Brown/Blue)
0.18
17
Sheath
Insulator
Conductor
Outside diameter [mm]Number of coresOutside diameter [mm]Effective area [mm2]Strand diameter [mm]
ø3.43 cores (Brown/Blue/Black)
ø1.10.2
ø0.0821
ø2.72 cores (Brown/Blue)
0.18
17
Oilproof Heavy-duty Lead Wire Specifications
Auto switch model0.5 m (Nil)
3 m (L)5 m (Z)
73150
1055—
D-Z73 D-Z76 D-Z80
Lead wire length
D-Z7 (With indicator light)Auto switch model
Applicable loadLoad voltageMax. load current and load current range(3)
Circuit diagram∗Contact protection circuitInternal voltage dropIndicator lightStandard
D-Z73
24 VDC (4)
5 to 40 mA100 VAC
5 to 20 mA
None
Red LED illuminates when turned ON.CE marking
D-Z76
D-Z80
Relay, PLC
e
2.4 V or less (Up to 20 mA)/3 V or less (Up to 40 mA)
IC circuit4 to 8 VDC
20 mAt
0.8 V or less
Relay, PLC, IC circuit
40 mAr
None1 Ω or less (Including 3 m lead wire)
CE marking
D-Z8 (Without indicator light)Auto switch model
Applicable load
Load voltage
Maximum load currentCircuit diagram∗Contact protection circuitInternal resistanceStandard
50 mA 20 mA
24 V or lessACDC 100 VAC
DC48 VACDC
731—
GrommetAuto Switch Specifications
PLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
Weight (g)
D-Z73, Z80 D-Z76
Dimensions (mm)
Slotted set screw
Slotted set screw
Indicator light
D-Z80 without indicator light
Indicator light
Most sensitive position
Most sensitive position
M2.5 x 4L
M2.5 x 4L
12.5
5.7
ø3.
4
Reed Auto SwitchDirect Mounting StyleD-Z73/D-Z76/D-Z80
1507
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
6.5
ø4
33
13
15 12
0.5
14.3
9.5
6.5
12.6ø4.5
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-B59WSheath
Insulator
Conductor
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
ø4
2 cores (Brown/Blue)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
Auto switch model
0.5 m (Nil)
3 m (L)
20
76
D-B59W
Lead wire length
Grommet
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
Auto Switch SpecificationsPLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.
D-B59W (With indicator light)Auto switch model
Applicable load
Load voltage
Load current range(3)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
D-B59W
Relay, PLC
24 VDC
5 to 40 mA
y
Built-in
4 V or less
Standard CE marking
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
Indicator light
Most sensitive position
Weight (g)
2-Color Indication Type Reed Auto SwitchBand Mounting StyleD-B59W
1508
1.8
36.
2
14
ø3.4
11.5 Most sensitive position
15
74
8
23.5
Indicator light
ø3.2
Auto switch model
0.5 m (Nil)
3 m (L)
11
53
D-A79W
Lead wire length
D-A79W (With indicator light)Auto switch model
Applicable load
Load voltage
Load current range (3)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
D-A79W
Relay, PLC
24 VDC
5 to 40 mA
u
None
4 V or less
Standard CE marking
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-A79WSheath
Insulator
Conductor
ø3.4
2 cores (Brown/Blue)
ø1.1
0.2
ø0.08
21
Oilproof Heavy-duty Lead Wire Specifications
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
2-Color Indication Type Reed Auto SwitchRail Mounting StyleD-A79W
Grommet
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
PLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
Weight (g)
1509
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
RelatedEquipment
D-
11
160.
5
Most sensitive position12
ø4
1233
23
134.
9
146
7
Indicator light
ø4.5
Auto switch model
0.5 m (Nil)
3 m (L)
25
80
D-A59W
Lead wire length
D-A59W (With indicator light)Auto switch model
Applicable load
Load voltage
Load current range(3)
Circuit diagram∗
Contact protection circuit
Internal voltage drop
Indicator light
Standard
D-A59W
Relay, PLC
24 VDC
5 to 40 mA
y
Built-in
4 V or less
CE marking
∗ Refer to the circuit diagram no. on page 1459.Note 1) Refer to page 1456 for reed auto switch common specifications.Note 2) Refer to page 1456 for lead wire lengths.Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Auto switch model
Lead wire minimum bending radius [mm] (Reference values)
D-A59WSheath
Insulator
Conductor
ø4
2 cores (Brown/Blue)
ø1.22
0.3
ø0.08
24
Oilproof Heavy-duty Lead Wire Specifications
Outside diameter [mm]
Number of cores
Outside diameter [mm]
Effective area [mm2]
Strand diameter [mm]
2-Color Indication Type Reed Auto SwitchTie-rod Mounting StyleD-A59W
Grommet
The proper operating range can be determined by the color of the light.(Red → Green ← Red)
PLC: Programmable Logic Controller
Refer to SMC website for the details of the products conforming to the international standards.Auto Switch Specifications
Operating range .......... Red LED illuminates.Proper operating range .......... Green LED illuminates.
Dimensions (mm)
Weight (g)
1510